Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

Embed Size (px)

Citation preview

Page 1: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

1

Pumps UK Catalogue 20

Page 2: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

2

Page 3: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

3

Espa Pumps (UK) Ltd is a subsidiary of the Spanish Espa Group and was founded in the UK in 1989.

Espa Pumps UK is based in Manningtree, Essex with a floor space of 10,000 sq. ft. It is a leading

manufacturer of packaged pumping equipment for the building services sector used in the boosting

of cold water, heating & cooling pressurisation systems and fire fighting sets.

In addition Espa provides efficient & reliable pumps and accessories for industrial & irrigation

processes, swimming pools, hydro massage, spas & wellness centres, rainwater harvesting and

many other sectors.

After sales support is given by a trained team, who can offer advice and on site commissioning.

Our commitment is to enter into a business relationship with our customers & suppliers that

guarantees complete satisfaction for all parties. Our goal is to assist our customers in gaining a

market advantage, while earning a fair return. Also to achieve an improved return on our investment

thorough quality, both in terms of service and the products supplied.

Since 1962 Espa has been developing a track record specialising in manufacturing products

equipment for pumping and efficient water management. Deploying solutions for professionals,

installers and wholesalers, through a range of innovative products.

Espa has become a leader in manufacturing pumping equipment for domestic, residential and

commercial uses. The Espa product portfolio provides excellent value due to its innovative nature

and design engineering. This offers the correct solution for the most demanding market requirements.

Tens of millions of Espa pumping equipment are in constant operation throughout the world.

Thousands of custom installations demonstrate the trust that professionals & users have placed in

Espa. Our customer base covers hotels, education centres, homes for the elderly, housing estates,

swimming pools, wellness centres, industrial units, logistic centres, arable & stock farms, gardens,

water treatment plants, mining operations & chemical plants.

Espa is a global organisation with local presence in its operational and distribution deployment.

It has sales organisations in Argentina, Brazil, Chile, China, France, Germany, India, Italy, Russia,

Spain, Turkey and the United Kingdom. It also has production centres in Chile, China, France and

Spain.

Innovation, engineering & service: These are the attributes that mark Espa’s efficient pumping

products and our quality. We are a customer-orientated organisation designed to be immediate

and close to the customer. We have a demanding product development process that is based on

knowledge of the technological and market requirements.

Espa Efficient Engineering sums up the spirit of innovation. It focuses on studying & applying the most

suitable technologies, plus the concept of efficient equipment for the pumping and engineering sector.

ESPA Pumps (UK) Ltd

3

Page 4: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

4

Index

Water Evacuation

Submersible & Drainage

Submersible

3” Borehole pumps

4’’ Plug & Go

ES4

6’’XS6

8’’XS8

10’’XS10

12’’XS12

A4I

O4I

A4F

A6F

A8F

Control Boxes

Franklin Accessories

Acuaria 07N/17/27

Acuaria 37/57

Idrogo

Drainage

MXO

Best

Best 2-5

Drain 100

DMR

Viginox

Viginox V

Drainex 100

TGR

Drainex 200/300

Drainex 400/500/600

Accessories

AL Series

S Series

AS Series

Draincor

GF Series

Control Panels

Drainbox 300/600

Drainbox 600/1000/1250/1500

Water Supply Surface

Horizontal & Vertical

Surface Horizontal

Prisma 15/25

Prisma 35N/45N

Prisma ESD

Aspri 15/25 MB

Aspri 35N/45N

Aspri ESD B

Tecno/Tecnoself

t

8

8

12

13

22

27

31

35

40

41

42

43

44

45

46

48

50

51

52

52

53

54

55

56

57

58

59

60

61

64

68

69

70

73

75

77

78

79

81

t

84

84

86

88

90

92

94

96

3” Borehole pumps

ES4

6’’XS6

8’’XS8

10’’XS10

12’’XS12

A4F

A6F

A8F

Franklin Accessories

Acuaria 07N/17/27

Acuaria 37/57

Idrogo

8

12

21

26

30

34

39

40

41

42

44

46

47

48

MXO

Best

Best 2-5

Drain 100

DMR

Viginox

Viginox V

Drainex 100

TGR

Drainex 200/300

Drainex 400/500/600

Accessories

AL Series

S Series

AS Series

Draincor

GF Series

Control Panels

Drainbox 300/600

Drainbox 600/1000/1250/1500

48

49

50

51

52

53

54

55

56

57

60

64

65

66

69

71

73

74

75

77

Prisma 15/25

Prisma 35N/45N

Prisma ESD

Aspri 15/25 MB

Aspri 35N/45N

Aspri ESD B

Tecno/Tecnoself

80

82

84

86

88

90

92

7

79

Page 5: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

5

UV System

Rainsub

Rainsub 2AL

Accessories

Accessories/

Control Panels & Inverters

Accessories

Accessories

Control Panels Q2P

Walter Filters

Multi Cyclone Filter

Inverters

Steadypres

DG Box

Speedrive

Special Pumps

J Series

Piscis

Residue Pump LSCI.4S

Industrial process

Technical Information

Technical Information

257

258

259

260

t

262

262

265

266

267

268

268

269

270

t274

275

277

278

t280

Sub-Tank 100AP

Sub-Tank 100/05

Sub-Tank 270/05

Sub-Tank 270.I

Sub-Tank 270/480.DI

Tecno Booster Sets

ES 1000

Wallpres Mini/Midi

Espres/Espres Delux

Espres Delux Twin System

Espres Delux Plus 150D

Espres Delux Plus 250/280 D

Espresmat

CKE Booster sets

Cat 5 Booster sets

CKA/CPA Booster sets

Water GRP break Tanks

Fire Sets

Accessories

RBX Surge Arrestor

Air & Dirt separation

Glandless Circulators

FL/FL4

FLD/FLD4

AP/AKP/AEP Series

AEP/LP/ALP Series

AE/L/AL/AKN Series

T/AT Series

Pressure Vessels

AFE/ACS/AFOSB/AFESB Series

Pressure Wave

Challenger

Other Vessels

Water Regeneration

Domestic Rainwater Harvesting

Direct Feed System

ECO 750 (Garden)

Header Tank System

X-Press 10 Eco

X.Press 10 Acuapres

Eco-System

Rainpres

Rain Collector

Commercial Rainwater Harvesting

X-Press 50

X-Press 100

SP50

SP75H

SP100H

Rainwater G Tanks

S-Line Display System

183

184

185

186

187

188

189

190

191

192

193

194

195

196

198

199

200

201

204

206

207

208

221

227

230

231

232

233

235

235

237

238

239

t242

242

243

244

245

246

247

248

249

250

250

251

252

253

254

255

256

Tecno ESD

Plus S

Per

PQ

Jet JA

Jet PA

Delta

FN/FN4

FNS

FNF/FNFT

TM/TMB/TMV

FSC

Surface Vertical

Multi

Multi ESD

Multi VX

Multi VX ESD

Multi VE

Pool & Wellness

Swimming Pool

Silen Plus

Basic/Niper

Iris/Silen

Silen 2

S3 Magnus

Star CF/BR 2

Star CF4

Star F/V Pre-filters

APCP

Wiper3

Nadorself

Wiper3/Nadorself accessories

Multipool Plus

Pool

Dosing Pumps HC

Hydromassage/Spa

Wiper0

Tiper 0/2/15

Pressure Building Services

Pressure

Pressdrive

Optimatic 05

Pressure Sets

Tecnopres

Tecnoplus 15

Tecnoplus 25

Acuapres

Acuaplus N

Building Services

Aquabox

98

100

104

105

106

107

108

109

121

122

124

125

127

127

129

131

144

148

t150

150

151

153

155

156

157

158

159

160

161

162

163

164

165

166

167

167

168

t172

172

173

174

175

177

178

179

180

181

181

Tecno ESD

Per

PQ

Jet JA

Delta

FN/FN4

FNS

FNF/FNFT

TM/TMB/TMV

FSC

Sub-Tank 100AP

Sub-Tank 100/05

Sub-Tank 270/05

Sub-Tank 270.I

Sub-Tank 270/480.DI

Tecno Booster Sets

ES 1000

Wallpres Mini/Midi

Espres/Espres Delux

Espres Delux Twin System

Espres Delux Plus 150D

Espres Delux Plus 250/280 D

Espresmat

CKE Booster sets

Cat 5 Booster sets

CKA/CPA Booster sets

Water GRP break Tanks

Fire Sets

Accessories

RBX Surge Arrestor

Air & Dirt separation

Glandless Circulators

FL/FL4

FLD/FLD4

AP/AKP/AEP Series

AEP/LP/ALP Series

AE/L/AL/AKN Series

T/AT Series

UV System

Rainsub

Rainsub 2AL

Accessories

Multi

Multi ESD

Multi VE

Basic/Niper

S3 Magnus

Star CF/BR 2

Star CF4

Star F/V Pre-filters

APCP

Pool

Dosing Pumps HC

Tiper 0/2/15

Optimatic 05

Pressure Sets

Tecnopres

Tecnoplus 15

Tecnoplus 25

Acuapres

Acuaplus N

Aquabox

94

96

97

98

99

100

112

113

115

116

118

120

122

124

126

127

128

129

130

131

132

138

139

140

142

143

144

145

146

148

149

150

151

152

153

154

155

156

157

158

159

160

161

163

164

165

166

169

171

172

173

186

192

195

196

197

198

AFE/ACS/AFOSB/AFESB Series

Pressure Wave

Challenger

Other Vessels

Direct Feed System

ECO 750 (Garden)

Header Tank System

X-Press 10 Eco

X.Press 10 Acuapres

Eco-System

Rainpres

Rain Collector

X-Press 50

X-Press 100

SP50

SP75H

SP100H

Rainwater G Tanks

S-Line Display System

200

202

203

204

208

209

210

211

212

213

214

215

216

216

217

218

219

220

221

222

Accessories

Control Panels Q2P

Walter Filters

Steadypres

DG Box

Speedrive

J Series

Piscis

Residue Pump LSCI.4S

Industrial Process

Technical Information

223

224

225

226

228

231

232

233

234

235

240

241

243

244

245

133

137

133

123

118

79207

79

227

Page 6: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

6

The Regulation (EU) N° 547/2012, implementing the Directive 2009/125/CE with regard to ecodesign for water pumps,

establishes:

1. From 1 January 2013, water pumps placed on the EU market shall have a minimum efficiency of MEI 0,1.

2. From 1 January 2015, water pumps placed on the EU market shall have a minimum efficiency of MEI 0,4.

ESPA pump series within this regulation:

ES4 Multi

ES4 01 (MEI 0,4) Multi 25 (MEI 0,4)

ES4 02 (MEI 0,4) Multi 35 (MEI 0,4)

ES4 03 (MEI 0,4) Multi 55 (MEI 0,4)

ES4 04 (MEI 0,4)

ES4 06 (MEI 0,4) Multi VX

ES4 08 (MEI 0,4) Multi VX1 (MEI 0,4)

ES4 10 (MEI 0,4) Multi VX3 (MEI 0,4)

ES4 12 (MEI 0,4) Multi VX5 (MEI 0,4)

ES4 16 (MEI 0,4) Multi VX10 (MEI 0,4)

Multi VX15 (MEI 0,4)

Acuaria Multi VX20 (MEI 0,4)

Acuaria 37 (MEI 0,4)

Acuaria 57 (MEI 0,4)

The benchmark for most efficient water pumps is MEI 0,7.

The operation of this water pump with variable duty points may be more efficient and economic when controlled, for

example, by the use of a variable speed drive that matches the pump duty to the system.Performance curves and any

other required information of the water pumps, as well as the information relevant for disassembly, recycling or disposal

at end-of-life of the pump are available within the instruction manual and the ESPA website www.espa.com.

The information on benchmark efficiency is available at http://global.espa.com/doc-descarrega-1/fingerprints.pdf.

Water pumps Ecodesign

Page 7: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

7

WATEREVACUATIONSUBMERSIBLE & DRAINAGE

Page 8: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

8

Equipment

WPS

Overload protection.

Internal surge arrester.

Incorporated Jam free check valve.

No capacitor, all integrated.

Heat shrink joint kit.

WPS CP sold as a kit consisting of:

high speed pump with motor,

electrical cable, control panel with

frequency drive 8 lt., pressure vessel,

manometer and a ball valve.

Limitations

Maximum liquid temperature: 40 °C.

Accessories

Cooling Shrouds.

Filters (3” WPS CP only, when the cable

length exceeds 120 m.)

3” Borehole Pumps Submersible

WPS & WPS CP submersible pumps

Applications

Domestic applications, irrigation,

pressurisation, water transfer,

suitable for wells 3” and above.

Materials

The pump is made entirely of

stainless steel and equipped with

special bearings resistant to high

speed performance.

Excellent resistance to wear.

Motor

WPS

Motor rating up to 1.5 kW, 140 Hz.

Single-phase supply.

Overvoltage & undervoltage.

WPS CP

High speed, maximum 8.200 rpm.

Discharge Rp 1 1/4”.

Very easy installation.

Motor developed to run at high speed

(140 Hz).

Constant pressure due to variable speed.

Protection against dry running.

Soft start and stop.

Single-phase supply to the controller.

Protection against over and under

voltage.

Two set pressures possible.

8

Page 9: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

9

3” Borehole Pumps Submersible

Technical data

Pump TypeNum. of

stages

Max. Pump

Power P2

[kW]

Pump data [mm]Weight

[kg]

Kit Flow [m3/h] Max.

Head [m]

at 0 [m3/h]

Full loand current

A B C [cm] [kg] 0,5 1 1,5 2 Motor Supply

3” WPS® 1-131 0,15 160

615 775 7,565 x 32 x 22 11,2 17 13 10 6 20

1,9

3,4

3” WPS®-CP 1-13 210 370 5,1 3,3

3” WPS® 1-252 0,29 180

615 795 7,765 x 32 x 22 10,4 33 26 21 12 39

2,3

3,9

3” WPS®-CP 1-25 210 390 5,3 3,8

3” WPS® 1-403 0,44 200

615 815 7,965 x 32 x 22 11,6 50 40 31 18 59

2,7

4,8

3” WPS®-CP 1-40 210 410 5,5 4,7

3” WPS® 1-504 0,58 220

615 835 8,165 x 32 x 22 11,8 66 53 42 24 78

3,1

5,6

3” WPS®-CP 1-50 210 430 5,7 5,4

3” WPS® 1-655 0,73 240

645 885 9,065 x 32 x 22 12,7 83 66 52 30 98

4,1

7,2

3” WPS®-CP 1-65 240 480 6,6 7,1

3” WPS® 1-756 0,87 260

645 905 9,265 x 32 x 22 12,9 100 79 62 36 117

4,6

8,0

3” WPS®-CP 1-75 240 500 6,8 8,0

3” WPS® 1-907 1,02 280

815 1095 10,065 x 32 x 22 13,7 116 92 73 42 137

6,1

10,5

3” WPS®-CP 1-90 270 550 7,6 10,6

3” WPS® 1-1008 1,16 300

815 1115 10,265 x 32 x 22 13,9 133 106 83 48 156

6,5

11,2

3” WPS®-CP 1-100 270 570 7,8 11,3

3” WPS® 1-1109 1,31 320

815 1135 10,465 x 32 x 22 14,1 149 119 94 54 176

6,9

11,9

3” WPS®-CP 1-110 270 590 8,0 12,0

3” WPS® 1-12510 1,45 340

815 1155 10,665 x 32 x 22 14,3 166 132 104 60 195

7,2

12,5

3” WPS®-CP 1-125 270 610 8,2 12,5

Ø76mm

RP 1 1/4”

A

C

B

Dimensions

3” WPS® 1, 3” WPS® CP 1

Performance curves

-125

-65

-90

-40

-110

-100

-50

-75

-25

-13

9

Page 10: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

10

3” Borehole Pumps Submersible

3” WPS® 2, 3” WPS® CP 2

Technical data

Pump TypeNum. of

stages

Max. Pump

Power P2

[kW]

Pump data [mm]Weight

[kg]

Kit Flow [m3/h] Max.

Head [m]

at 0 [m3/h]

Full loand current

A B C [cm] [kg] 0,5 1 1,5 2 2,5 Motor Supply

3” WPS® 2-131 0,19 160

615 775 7,565 x 32 x 22 11,2 20 18 16 13 10 21

2,0

3,6

3” WPS®-CP 2-13 210 370 5,1 3,5

3” WPS® 2-252 0,37 180

615 795 7,765 x 32 x 22 10,4 39 36 31 26 20 42

2,5

4,5

3” WPS®-CP 2-25 210 390 5,3 4,4

3” WPS® 2-403 0,56 200

615 815 7,965 x 32 x 22 11,6 59 53 47 39 30 62

3,1

5,5

3” WPS®-CP 2-40 210 410 5,5 5,4

3” WPS® 2-504 0,74 220

645 865 8,965 x 32 x 22 12,6 78 71 62 52 40 83

4,1

7,0

3” WPS®-CP 2-50 240 460 6,5 7,1

3” WPS® 2-655 0,90 240

645 885 9,165 x 32 x 22 12,8 98 89 78 65 50 104

4,7

8,2

3” WPS®-CP 2-65 240 480 6,7 8,2

3” WPS® 2-756 1,11 260

815 1075 10,065 x 32 x 22 13,7 117 107 93 78 60 125

6,1

10,5

3” WPS®-CP 2-75 270 530 7,6 10,6

3” WPS® 2-907 1,29 280

815 1095 10,265 x 32 x 22 13,9 137 124 109 91 70 145

6,8

11,7

3” WPS®-CP 2-90 270 550 7,8 11,8

3” WPS® 2-1008 1,48 300

815 1115 10,465 x 32 x 22 14,1 156 142 124 104 80 166

7,2

12,5

3” WPS®-CP 2-100 270 570 8,0 12,5

Performance curves Dimensions

Ø76mm

RP 1 1/4”

A

C

B

-100

-90

-75

-65

-50

-40

-25

-13

10

Page 11: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

11

3” Borehole Pumps Submersible

3” WPS® 3, 3” WPS® CP 3

Technical data

Pump TypeNum. of

stages

Max. Pump

Power P2

[kW]

Pump data [mm]Weight

[kg]

Kit Flow [m3/h] Max.

Head [m]

at 0 [m3/h]

Full loand current

A B C [cm] [kg] 1 2 2,5 3 3,5 4 Motor Supply

3” WPS® 3-151 0,29 160

615 775 7,565 x 32 x 22 11,2 21 19 17 16 13 10 22

2,8

4,9

3” WPS®-CP 3-15 210 370 5,1 4,9

3” WPS® 3-302 0,58 180

615 895 6,865 x 32 x 22 10,4 42 37 34 31 26 21 45

3,1

5,5

3” WPS®-CP 3-30 210 390 4,3 5,4

3” WPS® 3-453 0,87 200

645 845 8,765 x 32 x 22 12,4 62 56 52 47 40 31 67

4,6

7,9

3” WPS®-CP 3-45 240 440 6,3 8,0

3” WPS® 3-654 1,16 220

815 1035 9,765 x 32 x 22 13,4 83 74 69 62 53 42 90

6,3

10,8

3” WPS®-CP 3-65 270 490 7,3 10,9

3” WPS® 3-805 1,45 240

815 1055 9,965 x 32 x 22 13,6 104 93 86 78 66 52 112

7,1

12,3

3” WPS®-CP 3-80 270 510 7,5 12,3

Pump TypeNum. of

stages

Max. Pump

Power P2

[kW]

Pump data [mm]Weight

[kg]

Kit Flow [m3/h] Max.

Head [m]

at 0 [m3/h]

Full loand current

A B C [cm] [kg] 1 2 3 4 5 6 Motor Supply

3” WPS® 5-201 0,45 160

615 775 7,565 x 32 x 22 11,2 24 23 21 21 18 15 25

3,2

5,6

3” WPS®-CP 5-20 210 370 5,1 5,6

3” WPS® 5-352 0,90 180

645 825 8,565 x 32 x 22 12,2 47 44 42 39 35 29 50

4,7

8,2

3” WPS®-CP 5-35 240 420 6,1 8,2

3” WPS® 5-553 1,35 200

815 1015 9,565 x 32 x 22 13,2 70 67 64 59 53 42 75

7,2

12,4

3” WPS®-CP 5-55 270 470 7,1 12,5

Dimensions

Performance curves

3” WPS® 5, 3” WPS® CP 5

Ø76mm

RP 1 1/4”

A

C

B

-80

-65

-45

-30

-15

-55

-35

-20

11

Page 12: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

13

ES4 Submersible

Submersible pump with floating impellers

Applications

Domestic applications, irrigation,

pressurisation, water transfer,

suitable for 4” wells and above.

Materials

Outer case, discharge body, suction

strainer, pump suport and pump shaft

in stainless steel AISI 304.

Diffusers in technopolymer.

Floating impellers in Noryl

(glass loaded polymer).

Motor

Franklin water cooled as standard.

Espa water & oil cooled on request.

Class B insulation.

Protection IP 68.

Continuous operation.

Complete with built-in thermal

protection.

Energy Index MEI 0,4.

Limitations

Maximum liquid temperature: 40 °C.

Maximum quantity of sand in

suspension: 150 g/m3.

Equipment

Complete with pre-fitted cable tail.

Integral non return valve.

Capacitor box

(Single-phase only, included up to 1.1.

1.5 kW and above extra).

Heat shrink joint kit

(option of resin joint).

12

Page 13: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

14

ES4 01 Submersible

Model

P2

[kW]

0.37

0.37

0.55

0.75

1.1

[HP]

0.5

0.5

0.75

1

1.5

0

0

67

86

126

173

253

0.3

5

63

78

118

160

234

0.6

10

55

70

105

141

208

0.9

15

46

56

86

117

169

1.2

20

33

42

60

81

117

1.5

25

18

23

30

39

52

m3/h

l/min

mw

c

ES4 01 10

ES4 01 13

ES4 01 19

ES4 01 26

ES4 01 38

Hydraulic performance table

Dimensions and weights

ES4 01 10 M 04I

ES4 01 13 M O4I

ES4 01 19 M O4I

ES4 01 26 M O4I

ES4 01 38 M O4I

ES4 01 10 T O4I

ES4 01 13 T O4I

ES4 01 19 T O4I

ES4 01 26 T O4I

ES4 01 38 T O4I

ES4 01 10 M A4I

ES4 01 13 M A4I

ES4 01 19 M A4I

ES4 01 26 M A4I

ES4 01 38 M A4I

ES4 01 10 T A4I

ES4 01 13 T A4I

ES4 01 19 T A4I

ES4 01 26 T A4I

ES4 01 38 T A4I

Model

Dimensions [mm] Weight Electropump

324

377

481

642

864

324

377

481

642

864

324

377

481

642

864

324

377

481

642

864

10.6

11.0

12.6

14.8

19.1

10.1

10.5

11.0

13.7

17.2

10.3

10.7

12.3

14.0

18.9

10.1

10.5

11.7

13.4

16.4

3.3

3.7

4.7

5.8

8.2

3.3

3.7

4.7

5.8

8.2

3.3

3.7

4.7

5.8

8.2

3.3

3.7

4.7

5.8

8.2

679

732

861

1057

314

658

732

836

1022

1279

560

643

767

973

1257

540

613

747

928

1212

L1 L

Weight pump

[kg] [kg]RP/NPT 1 1/4” RP/NPT 1 1/4”

Performance curves at 2900 rpm

ES4 01 38

ES4 01 19

ES4 01 26

ES4 01 13

ES4 01 10

13

Page 14: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

15

ES4 02 Submersible

ES4 02 05 M O4I

ES4 02 07 M O4I

ES4 02 10 M O4I

ES4 02 14 M O4I

ES4 02 20 M O4I

ES4 02 28 M O4I

ES4 02 40 M O4I

ES4 02 05 T O4I

ES4 02 07 T O4I

ES4 02 10 T O4I

ES4 02 14 T O4I

ES4 02 20 T O4I

ES4 02 28 T O4I

ES4 02 40 T O4I

ES4 02 52 T O4I

ES4 02 05 M A4I

ES4 02 07 M A4I

ES4 02 10 M A4I

ES4 02 14 M A4I

ES4 02 20 M A4I

ES4 02 28 M A4I

ES4 02 40 M A4I

ES4 02 05 T A4I

ES4 02 07 T A4I

ES4 02 10 T A4I

ES4 02 14 T A4I

ES4 02 20 T A4I

ES4 02 28 T A4I

ES4 02 40 T A4I

ES4 02 52 T A4I

Model

Dimensions [mm] Weight Electropump

236

271

324

394

499

640

851

236

271

324

394

499

640

851

1062

236

271

324

394

499

640

851

236

271

324

394

499

640

851

1062

9.8

10.1

11.2

12.9

15.8

18.7

22.9

9.3

9.6

10.6

11.8

13.9

17.3

20.7

23.3

9.5

9.8

10.9

12.1

15.6

18.7

22.1

9.3

9.6

10.3

11.5

13.1

18.0

20.7

30.4

2.5

2.8

3.3

3.9

4.9

6.2

8.1

2.5

2.8

3.3

3.9

4.9

6.2

8.1

10.0

2.5

2.8

3.3

3.9

4.9

6.2

8.1

2.5

2.8

3.3

3.9

4.9

6.2

8.1

10.0

591

626

679

774

914

1090

1351

570

605

679

749

879

1055

1301

1512

472

507

590

680

830

1033

1264

452

487

560

660

785

988

1244

1606

L1 L

Weight pump

[kg] [kg]

Model

P2

[kW] [HP] 0

0

1.2

20

1.5

25

1.8

30

2.4

40

3.0

50

0.37

0.37

0.55

0.75

1.1

1.5

2.2

3

0.5

0.5

0.75

1

1.5

2

3

4

34

46

69

92

139

193

276

360

31

42

63

83

127

176

252

328

29

39

60

79

120

167

239

312

27

36

55

74

111

155

222

289

23

29

44

60

90

125

179

233

16

22

29

42

60

83

118

154

m3/h

l/min

mw

c

ES4 02 05

ES4 02 07

ES4 02 10

ES4 02 14

ES4 02 20

ES4 02 28

ES4 02 40

ES4 02 52

RP/NPT 1 1/4” RP/NPT 1 1/4”

ES4 02 05

ES4 02 07

ES4 02 10

ES4 02 14

ES4 02 20

ES4 02 28

ES4 02 40

ES4 02 52

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

14

Page 15: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

16

ES4 03 Submersible

ES4 03 05 M O4I

ES4 03 08 M O4I

ES4 03 11 M O4I

ES4 03 16 M O4I

ES4 03 21 M O4I

ES4 03 32 M O4I

ES4 03 05 T O4I

ES4 03 08 T O4I

ES4 03 11 T O4I

ES4 03 16 T O4I

ES4 03 21 T O4I

ES4 03 32 T O4I

ES4 03 05 M A4I

ES4 03 08 M A4I

ES4 03 11 M A4I

ES4 03 16 M A4I

ES4 03 21 M A4I

ES4 03 32 M A4I

ES4 03 05 T A4I

ES4 03 08 T A4I

ES4 03 11 T A4I

ES4 03 16 T A4I

ES4 03 21 T A4I

ES4 03 32 T A4I

Model

Dimensions [mm] Weight Electropump

236

289

342

430

519

749

236

289

342

430

519

749

236

289

342

430

519

749

236

289

342

430

519

749

9.8

10.8

12.4

15.1

17.5

21.9

9.3

10.2

11.3

13.2

16.1

19.7

9.5

10.5

11.6

14.9

17.5

21.1

9.3

9.9

11.0

12.4

16.8

19.7

2.5

2.9

3.4

4.2

5.0

7.1

2.5

2.9

3.4

4.2

5.0

7.1

2.5

2.9

3.4

4.2

5.0

7.1

2.5

2.9

3.4

4.2

5.0

7.1

591

644

722

845

969

1249

570

644

697

810

934

1199

472

555

628

761

912

1162

452

525

608

716

867

1142

L1 L

Weight pump

[kg] [kg]

Model

P2

[kW] [HP] 0

0

1.2

20

1.8

30

2.4

40

3.0 4.2

50 70

0.37

0.55

0.75

1.1

1.5

2.2

0.5

0.75

1

1.5

2

3

34

54

72

106

142

208

32

51

68

101

135

200

30

49

64

95

127

187

28

43

58

83

115

165

24

38

49

70

100

138

13

19

26

33

49

62

m3/h

l/min

mw

c

ES4 03 05

ES4 03 08

ES4 03 11

ES4 03 16

ES4 03 21

ES4 03 32

RP/NPT 1 1/4” RP/NPT 1 1/4”

ES4 03 05

ES4 03 08

ES4 03 11

ES4 03 16

ES4 03 21

ES4 03 32

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

15

Page 16: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

17

ES4 04 Submersible

Model

P2

[kW] [HP] 0

0

2.4

40

3.0

50

4.2

70

5.4 6.0

90 100

0.37

0.55

0.75

1.1

1.5

2.2

3

3.7

4

0.5

0.75

1

1.5

2

3

4

5

5.5

26

38

51

77

102

151

203

253

278

22

35

46

71

96

139

185

227

260

21

32

43

68

92

132

175

216

247

17

26

35

57

77

111

146

182

210

11

18

24

41

57

80

105

131

159

7

12

18

31

46

62

80

102

127

m3/h

l/min

mw

c

ES4 04 04

ES4 04 06

ES4 04 08

ES4 04 12

ES4 04 16

ES4 04 24

ES4 04 32

ES4 04 40

ES4 04 44

ES4 04 04

ES4 04 08

ES4 04 06

ES4 04 12

ES4 04 16

ES4 04 24

ES4 04 32

ES4 04 40

ES4 04 44

ES4 04 04 M O4I

ES4 04 06 M O4I

ES4 04 08 M O4I

ES4 04 12 M O4I

ES4 04 16 M O4I

ES4 04 24 M O4I

ES4 04 04 T O4I

ES4 04 06 T O4I

ES4 04 08 T O4I

ES4 04 12 T O4I

ES4 04 16 T O4I

ES4 04 24 T O4I

ES4 04 32 T O4I

ES4 04 40 T O4I

ES4 04 44 T O4I

ES4 04 04 M A4I

ES4 04 06 M A4I

ES4 04 08 M A4I

ES4 04 12 M A4I

ES4 04 16 M A4I

ES4 04 24 M A4I

ES4 04 04 T A4I

ES4 04 06 T A4I

ES4 04 08 T A4I

ES4 04 12 T A4I

ES4 04 16 T A4I

ES4 04 24 T A4I

ES4 04 32 T A4I

ES4 04 40 T A4I

ES4 04 44 T A4I

Model

Dimensions [mm] Weight Electropump

247

296

345

433

542

777

247

296

345

433

542

777

965

1160

1296

247

296

345

433

542

777

247

296

345

433

542

777

965

1160

1296

9.7

10.8

12.3

15.0

17.5

21.4

9.2

10.2

11.2

13.1

16.1

19.2

22.3

27.9

28.7

9.4

10.5

11.5

14.8

17.5

20.6

9.2

9.9

10.9

12.3

16.8

19.2

29.1

33.9

34.7

2.4

2.9

3.3

4.1

5.0

6.6

2.4

2.9

3.3

4.1

5.0

6.6

8.7

10.4

11.2

2.4

2.9

3.3

4.1

5.0

6.6

2.4

2.9

3.3

4.1

5.0

6.6

8.7

10.4

11.2

602

651

725

848

992

1277

581

651

700

813

957

1227

1415

1730

1866

483

562

631

764

935

1190

463

532

611

719

890

1170

1509

1774

1910

L1 L

Weight pump

[kg] [kg]RP/NPT 1 1/4” RP/NPT 1 1/4”

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

16

Page 17: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

18

ES4 06 Submersible

ES4 06 07 M O4I

ES4 06 10 M O4I

ES4 06 14 M O4I

ES4 06 20 M O4I

ES4 06 07 T O4I

ES4 06 10 T O4I

ES4 06 14 T O4I

ES4 06 20 T O4I

ES4 06 27 T O4I

ES4 06 34 T O4I

ES4 06 36 T O4I

ES4 06 49 T O4I

ES4 06 07 M A4I

ES4 06 10 M A4I

ES4 06 14 M A4I

ES4 06 20 M A4I

ES4 06 07 T A4I

ES4 06 10 T A4I

ES4 06 14 T A4I

ES4 06 20 T A4I

ES4 06 27 T A4I

ES4 06 34 T A4I

ES4 06 36 T A4I

ES4 06 49 T A4I

Model

Dimensions [mm] Weight Electropump

390

483

607

831

390

483

607

831

1048

1257

1318

1802

390

483

607

831

390

483

607

831

1048

1257

1318

1802

12.7

15.5

18.2

22.3

11.6

13.6

16.8

20.1

23.2

29.1

29.7

36.9

11.9

15.3

18.2

21.5

11.3

12.8

17.5

20.1

30.0

35.1

35.7

42.7

3.7

4.6

5.7

7.5

3.7

4.6

5.7

7.5

9.6

11.6

12.2

15.9

3.7

4.6

5.7

7.5

3.7

4.6

5.7

7.5

9.6

11.6

12.2

15.9

770

898

1057

1331

745

863

1022

1271

1498

1827

1888

2432

676

814

1000

1244

656

769

955

1224

1592

1871

1935

2486

L1 L

Weight pump

[kg] [kg]

Model

P2

[kW] [HP] 0

0

3.0

50

4.2

70

5.4

90

7.2 8.4

120 140

0.75

1.1

1.5

2.2

3.0

3.7

4

5.5

1

1.5

2

3

4

5

5.5

7.5

42

62

90

125

169

208

221

302

36

53

77

107

145

178

190

257

32

48

71

97

131

162

173

234

28

41

63

86

115

143

154

209

19

29

46

62

84

103

112

151

11

18

28

40

55

66

72

96

m3/h

l/min

mw

c

ES4 06 07

ES4 06 10

ES4 06 14

ES4 06 20

ES4 06 27

ES4 06 34

ES4 06 36

ES4 06 49

RP/NPT 1 1/4” RP/NPT 1 1/4”

ES4 06 07

ES4 06 10

ES4 06 14

ES4 06 27

ES4 06 34

ES4 06 36

ES4 06 49

ES4 06 20

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

17

Page 18: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

19

ES4 08 Submersible

ES4 08 04 M O4I

ES4 08 06 M O4I

ES4 08 08 M O4I

ES4 08 13 M O4I

ES4 08 04 T O4I

ES4 08 06 T O4I

ES4 08 08 T O4I

ES4 08 13 T O4I

ES4 08 17 T O4I

ES4 08 21 T O4I

ES4 08 23 T O4I

ES4 08 32 T O4I

ES4 08 43 T O4I

ES4 08 04 M A4I

ES4 08 06 M A4I

ES4 08 08 M A4I

ES4 08 13 M A4I

ES4 08 04 T A4I

ES4 08 06 T A4I

ES4 08 08 T A4I

ES4 08 13 T A4I

ES4 08 17 T A4I

ES4 08 21 T A4I

ES4 08 23 T A4I

ES4 08 32 T A4I

ES4 08 43 T A4I

Model

Dimensions [mm] Weight Electropump

294

356

418

573

294

356

418

573

697

859

921

1238

1603

294

356

418

573

294

356

418

573

697

859

921

1238

1603

11.8

14.3

16.5

20.3

10.7

12.4

15.1

18.1

20.2

25.3

25.9

32.0

42.7

11.0

14.1

16.5

19.5

10.4

11.6

15.8

18.1

27.0

31.3

31.9

37.8

43.2

2.8

3.4

4.0

5.5

2.8

3.4

4.0

5.5

6.6

7.8

8.4

11.0

14.2

2.8

3.4

4.0

5.5

2.8

3.4

4.0

5.5

6.6

7.8

8.4

11.0

14.2

674

771

868

1073

649

736

833

1023

1147

1429

1491

1868

2439

580

687

811

986

560

642

766

966

1241

1473

1535

1922

2367

L1 L

Weight pump

[kg] [kg]

Model

P2

[kW] [HP] 0

0

4.8

80

6.0

100

8.4

140

10.8 12

180 200

0.75

1.1

1.5

2.2

3

3.7

4

5.5

7.5

1.0

1.5

2

3

4

5

5.5

7.5

10

26

39

52

82

108

132

148

202

272

24

36

48

75

98

117

134

182

244

22

34

46

71

94

111

127

172

230

19

29

39

59

79

93

108

143

193

15

22

29

40

58

68

79

105

141

12

17

24

30

46

52

60

80

107

m3/h

l/min

mw

c

ES4 08 04

ES4 08 06

ES4 08 08

ES4 08 13

ES4 08 17

ES4 08 21

ES4 08 23

ES4 08 32

ES4 08 43

RP/NPT 2” RP/NPT 2”

ES4 08 43

ES4 08 04

ES4 08 08

ES4 08 13

ES4 08 17

ES4 08 21

ES4 08 23

ES4 08 32

ES4 08 06

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

18

Page 19: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

20

ES4 12 Submersible

ES4 12 07 M O4I

ES4 12 10 M O4I

ES4 12 07 T O4I

ES4 12 10 T O4I

ES4 12 14 T O4I

ES4 12 17 T O4I

ES4 12 19 T O4I

ES4 12 26 T O4I

ES4 12 34 T O4I

ES4 12 07 M A4I

ES4 12 10 M A4I

ES4 12 07 T A4I

ES4 12 10 T A4I

ES4 12 14 T A4I

ES4 12 17 T A4I

ES4 12 19 T A4I

ES4 12 26 T A4I

ES4 12 34 T A4I

Model

Dimensions [mm] Weight Electropump

534

690

534

690

989

1092

1195

1559

2007

534

690

534

690

989

1092

1195

1559

2007

17.8

21.5

16.4

19.3

22.2

27.6

28.5

35.3

46.6

17.8

20.7

17.1

19.3

29.0

33.6

34.5

41.1

47.1

5.3

6.7

5.3

6.7

8.6

10.1

11.0

14.3

18.1

5.3

6.7

5.3

6.7

8.6

10.1

11.0

14.3

18.1

984

1190

949

1140

1439

1662

1765

2189

2843

927

1103

882

1083

1533

1706

1809

2243

2771

L1 L

Weight pump

[kg] [kg]

Model

P2

[kW] [HP] 0

0

6.0

100

8.4

140

10.8

180

13.2 15.6

220 260

1.5

2.2

3

3.7

4

5.5

7.5

2

3

4

5

5.5

7.5

10

45

64

89

107

120

163

213

37

54

76

90

102

136

179

33

48

67

80

91

120

158

28

41

56

67

76

100

131

22

32

43

51

58

75

98

14

20

28

32

37

48

63

m3/h

l/min

mw

c

ES4 12 07

ES4 12 10

ES4 12 14

ES4 12 17

ES4 12 19

ES4 12 26

ES4 12 34

RP/NPT 2” RP/NPT 2”

ES4 12 07

ES4 12 10

ES4 12 14

ES4 12 17

ES4 12 19

ES4 12 26

ES4 12 34

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

19

Page 20: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

21

ES4 16 Submersible

ES4 16 08 M O4I

ES4 16 08 T O4I

ES4 16 11 T O4I

ES4 16 13 T O4I

ES4 16 15 T O4I

ES4 16 20 T O4I

ES4 16 27 T O4I

ES4 16 07 M A4I

ES4 16 07 T A4I

ES4 16 10 T A4I

ES4 16 14 T A4I

ES4 16 17 T A4I

ES4 16 26 T A4I

ES4 16 27 T A4I

Model

Dimensions [mm] Weight Electropump

676

676

880

1013

1149

1489

1962

676

676

880

1013

1149

1489

1962

21.1

18.9

21.7

26.8

28.0

34.5

46.2

20.3

18.9

28.5

32.8

34.0

40.3

46.7

6.3

6.3

8.1

9.3

10.5

13.5

17.7

6.3

6.3

8.1

9.3

10.5

13.5

17.7

1176

1126

1330

1583

1719

2119

2798

1089

1069

1424

1627

1763

2173

2726

L1 L

Weight pump

[kg] [kg]

Model

P2

[kW] [HP] 0

0

8.4

140

12

200

15.6

260

19.2 24

320 400

2.2

3

3.7

4

5.5

7.5

3

4

5

5.5

7.5

10

51

70

81

97

125

169

41

57

67

79

102

139

35

49

58

69

89

122

29

41

48

58

74

101

22

31

38

46

60

83

12

18

22

27

37

52

m3/h

l/min

mw

c

ES4 16 08

ES4 16 11

ES4 16 13

ES4 16 15

ES4 16 20

ES4 16 27

RP/NPT 2” RP/NPT 2”

ES4 16 08

ES4 16 11

ES4 16 13

ES4 16 15

ES4 16 20

ES4 16 27

Dimensions and weights

Hydraulic performance tablePerformance curves at 2900 rpm

20

Page 21: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

22

Applications

For deep wells with minimum diameter

of 158 mm, water supply, fountains,

irrigation, pressure boosting, dewatering,

mining & other civil/industrial

applications.

Materials

Suction support in cast iron (EN-GJL-250).

Shaft & coupling in Stainless Steel

AISI 431.

Impeller & diffuser in cast iron

(EN-GJL-250).

Options:

Fully Stainless Steel AISI 316 (XSX6).

Fully Bronze (XSB6).

Motor

Water or oiled option, 2900 rpm.

Class B insulation.

IP 68 protection.

Continuous & intermittent operation.

Complete with built-in-thermal

protection.

Connected in accordance with NEMA

standard:

4’’ NEMA MG1–18.388 or

6’’ NEMA MG1-18.401-18.413.

6’’ XS6 Submersible

6’’ Semi-Axial submersible pumps

Range

XS6 K Q max: 36 m3/hr-H max: 275.5 mtrs.

XS6 X Q max: 39 m3/hr-H max: 390 mtrs.

XS6 A Q max: 60 m3/hr-H max: 325 mtrs.

XS6 B Q max: 72 m3/hr-H max: 280 mtrs.

XS6 C Q max: 90 m3/hr-H max: 231 mtrs.

Construction features

Semi-axial impellers.

3’’ outlet c/w non return valve.

Pump equipped with counter thrust ring

in anti-wear resin.

Diffuser c/w wear ring in anti-wear

rubber.

Driving bushings in anti-wear rubber

with metallic shell.

Components realised with particular

materials which assure in high wear

resistance.

Limitations

Maximum liquid temperature 30 °C.

Maximum immersion depth 300 m under

liquid level.

Clean non-aggressive and non-explosive

liquids, not containing solid particles

more than 2 mm.

Hydraulic performance table

XS6(K)

ModelI [A] P2** l/min 0 66.7 83.3 100 117 133 150 167 200 250 300

3~ 400 V [kW] [HP] m3/h 0 4 5 6 7 8 9 10 12 15 18

XS6(K)/5* 7.6 3 4

mw

c

71 63 62 59 57 54 51 49 42 30 14

XS6(K)/7* 9.3 4 5.5 100 88 86 83 79 76 72 69 60 42.5 20

XS6(K)/8* 11 5.5 7.5 114 101 99 95 91 87 83 79 68 48.5 23

XS6(K)/9* 11.5 5.5 7.5 128 114 111 106 102 98 93 89 77 53 25

XS6(K)/10* 12.2 5.5 7.5 142 126 123 118 113 108 103 98 85 59.5 28

XS6(K)/11* 16.3 7.5 10 156 139 136 130 125 119 114 108 94 65.5 31

XS6(K)/12* 16.3 7.5 10 171 151 147 142 136 130 124 118 102 72 34

XS6(K)/13* 16,3 7.5 10 185 164 160 154 147 141 134 128 111 78.5 37

XS6(K)/16 19.9 9.2 12.5 228 202 197 189 181 173 165 157 136 95.5 45

XS6(K)/19 23.7 11 15 270 240 232 224 215 205 196 187 162 115 53

XS6(K)/22 27.7 13 17.5 317 281 271 260 249 238 227 214 187 134 62

XS6(K)/26 30.4 15 20 369 328 318 307 294 281 268 255 221 159 73

XS6(K)/29 38 18.5 25 412 366 353 342 328 313 299 284 247 176 81

XS6(K)/32 38 18.5 25 456 403 392 378 362 346 330 314 272 195 90

* The group is also available in special version for horizontal operation

** Rated power of motor

21

Page 22: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

23

6’’ XS6 Submersible

Hydraulic performance table

XS6(X)

ModelI [A] P2** l/min 0 200 250 300 350 400 450 500 550 600 650

3~ 400 V [kW] [HP] m3/h 0 12 15 18 21 24 27 30 33 36 39

XS6(X)/3* 7.6 3 4

mw

c

45 38 36 34 31 28 25 21 17 13 7.5

XS6(X)/4* 9.3 4 5.5 60 51 48 45 42 37 33 28 23 17 10

XS6(X)/5* 12.2 5.5 7.5 75 64 60 57 52 47 41 35 28 21 13

XS6(X)/7* 16.3 7.5 10 105 90 84 79 73 65 58 49 39 29 18

XS6(X)/8* 19.9 9.2 12.5 120 103 96 91 84 75 66 56 45 33 20

XS6(X)/10* 23.7 11 15 150 128 120 113 104 93 82 69 56 41 25

XS6(X)/12 27.7 13 17.5 180 154 144 136 125 112 99 83 68 50 30

XS6(X)/14 30.4 15 20 210 180 168 159 146 131 115 97 79 58 35

XS6(X)/17 38 18.5 25 255 218 204 192 177 158 140 118 96 70 43

XS6(X)/20 43.7 22 30 300 256 240 226 208 186 164 138 112 82 50

XS6(X)/22 53.3 26 35 330 282 264 249 229 205 181 152 124 91 55

XS6(X)/24 53.3 26 35 360 308 288 272 250 224 197 166 135 99 60

XS6(X)/26 60.2 30 40 390 333 312 294 271 242 214 180 146 107 65

XS6(A)

ModelI [A] P2** l/min 0 200 250 300 350 400 450 500 550 600 700 800 900 1000

3~ 400 V [kW] [HP] m3/h 0 12 15 18 21 24 27 30 33 36 42 48 54 60

XS6(A)/2* 9.4 4 5.5

mw

c

35 30 29 28 27 26 25 24 23 22 20 17 13 9

XS6(A)/3* 12.2 5.5 7.5 52 48 47.5 46 45 43 42 41 39 37 33 28 23 17

XS6(A)/4* 16.3 7.5 10 69 64 62 61 59 57 55 53 52 49 46 37 30 23

XS6(A)/5* 19.9 9.2 12.5 86 80 79 77 75 72 70 67 65 62 55 47 38 29

XS6(A)/6* 23.7 11 15 103 96 93 91 88 85 83 80 76 73 65 56 46 34

XS6(A)/7* 27.7 13 17.5 122 111 109 104 102 98 95 91 89 85 78 65 55 40

XS6(A)/8* 33 15 20 137 128 124 121 117 113 110 106 101 98 90 77 65 48

XS6(A)/9* 38 18.5 25 155 142 137 134 129 126 122 119 115 112 104 87 71 54

XS6(A)/10* 38 18.5 25 171 156 153 149 145 140 137 132 128 124 114 96 79 60

XS6(A)/11 43.7 22 30 187 172 168 164 159 155 151 146 141 137 127 106 87 66

XS6(A)/12 46 22 30 208 190 185 180 176 170 165 160 154 149 137 117 99 77

XS6(A)/13 53.3 26 35 224 206 200 195 190 184 178 173 167 159 150 127 107 83

XS6(A)/14 60.2 30 40 244 223 217 212 206 200 194 189 181 175 160 140 114 88

XS6(A)/15 60.2 30 40 257 235 230 223 218 212 205 199 192 185 173 150 122 94

XS6(A)/16 62 30 40 276 250 243 238 231 224 217 210 204 197 183 160 130 100

XS6(A)/17 73 37 50 293 266 258 251 245 238 232 226 218 211 196 170 138 107

XS6(A)/18 73 37 50 309 279 271 264 258 251 245 238 229 222 207 180 146 113

XS6(A)/19 75 37 50 326 295 286 278 272 265 258 252 244 236 219 190 154 119

* The group is also available in special version for horizontal operation

** Rated power of motor

* The group is also available in special version for horizontal operation

** Rated power of motor

22

Page 23: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

24

6’’ XS6 Submersible

Hydraulic performance table

XS6(B)

ModelI [A] P2** l/min 0 400 450 500 550 600 700 800 900 1000 1100 1150 1200

3~ 400 V [kW] [HP] m3/h 0 24 27 30 33 36 42 48 54 60 66 69 72

XS6(B)/2A* 9.4 4 5.5

mw

c

32 27 26 25.5 25 24 23 20 19 17 15 13 11

XS6(B)/2* 12.2 5.5 7.5 33 29 28.5 28 27 26 25 24 22 20 18 16 14

XS6(B)/3* 16.3 7.5 10 50 44 43 42 41 40 37 34 32 29 25 23 20

XS6(B)/4* 19.9 9.2 12.5 66 58 56 55 54 52 49 44 41 37 32 30 26

XS6(B)/5* 25 11 15 83 71 70 67 65 63 59 56 51 46 41 38 33

XS6(B)/6* 27.7 13 17.5 99 88 85 83 80 77 72 68 63 57 50 46 39

XS6(B)/7* 32 15 20 116 102 99 97 93 89 85 80 73 67 58 53 46

XS6(B)/8* 38 18.5 25 132 113 110 108 105 102 97 90 83 75 66 61 52

XS6(B)/9* 44.5 22 30 149 126 124 121 118 114 108 101 93 85 75 69 59

XS6(B)/10* 45.5 22 30 165 140 137 134 130 128 120 112 104 94 83 77 65

XS6(B)/11 53.3 26 35 182 158 152 149 144 140 132 124 114 103 91 84 72

XS6(B)/12 55 26 35 198 173 167 162 157 153 145 135 125 114 99 92 78

XS6(B)/13 60.2 30 40 215 186 180 176 170 165 156 146 135 123 107 99 85

XS6(B)/14 62 30 40 231 201 192 188 183 178 168 158 146 132 116 107 91

XS6(B)/15 73 37 50 248 215 207 202 196 191 180 169 156 141 124 114 98

XS6(B)/16 74.5 37 50 264 229 221 216 210 204 193 181 168 152 132 122 104

XS6(B)/17 76 37 50 281 242 236 230 222 217 204 193 179 162 141 130 111

XS6(C)

ModelI [A] P2** l/min 0 900 1000 1100 1150 1200 1250 1300 1400 1500

3~ 400 V [kW] [HP] m3/h 0 54 60 66 69 72 75 78 84 90

XS6(C)/2* 13 5.5 7.5

mw

c

32 21 20 18 18 17 16 15 13 10

XS6(C)/3* 19.9 9.2 12.5 48 32 31 28 27 26 24 23 19 15

XS6(C)/4* 23.7 11 15 64 44 41 38 37 34 32 30 25 20

XS6(C)/5* 29 13 17.5 80 55 52 48 46 43 41 38 32 24

XS6(C)/6A* 30.4 15 20 95 64 60 56 54 50 47 43 36 27

XS6(C)/6* 38 18.5 25 96 66 62 58 55 52 49 45 38 30

XS6(C)/7* 40 18.5 25 112 77 72 66 63 60 57 53 44 35

XS6(C)/8* 45 22 30 128 87 82 75 72 68 64 60 50 39

XS6(C)/9* 53.3 26 35 144 99 92 85 81 77 72 68 56 44

XS6(C)/10* 55 26 35 160 110 102 95 90 85 80 75 62 49

XS6(C)/11 60.2 30 40 176 120 113 105 100 95 90 83 69 54

XS6(C)/12 73 37 50 192 132 124 114 109 104 98 91 75 59

XS6(C)/13 73 37 50 208 143 134 123 117 111 105 98 81 64

XS6(C)/14 76 37 50 224 153 145 133 126 120 113 105 87 69

* The group is also available in special version for horizontal operation

** Rated power of motor

* The group is also available in special version for horizontal operation

** Rated power of motor

23

Page 24: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

25

6’’ XS6 Submersible

Dimensions and weights

XS6(K)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS6(K)/5 SP151K/5 1268 739 529 148 3’’ 95 4’’CL 95 NEMA 1.18.388 42.5 58.8

XS6(K)/7 SP151K/7 1508 899 609 148 3’’ 95 4’’CL 95 NEMA 1.18.388 53 73.1

XS6(K)/8 SP151K/8 1531 979 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 58 102

XS6(K)/9 SP151K/9 1611 1059 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 63 107

XS6(K)/10 SP151K/10 1691 1139 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 68 112

XS6(K)/11 SP151K/11 1814 1219 595 152 3’’ 144 6’’MS 152 NEMA 1.18.413 73 122

XS6(K)/12 SP151K/12 1894 1299 595 152 3’’ 144 6’’MS 152 NEMA 1.18.413 78 127

XS6(K)/13 SP151K/13 1974 1379 595 152 3’’ 144 6’’MS 152 NEMA 1.18.413 83 132

XS6(K)/16 SP151K/16 2254 1619 635 152 3’’ 144 6’’MS 152 NEMA 1.18.413 98 152

XS6(K)/19 SP151K/19 2544 1859 685 152 3’’ 144 6’’MS 152 NEMA 1.18.413 113 173

XS6(K)/22 SP151K/22 2824 2099 725 152 3’’ 144 6’’MS 152 NEMA 1.18.413 128 190

XS6(K)/26 SP151K/26 3194 2419 775 152 3’’ 144 6’’MS 152 NEMA 1.18.413 143 208

XS6(K)/29 SP151K/29 3534 2659 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 150 231

XS6(K)/32 SP151K/32 3774 2899 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 173 254

XS6(X)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS6(X)/3 SP152X/3 1183 654 529 148 3’’ 95 4’’CL 95 NEMA 1.18.388 32.5 48.8

XS6(X)/4 SP152X/4 757 759 609 148 3’’ 95 4’’CL 95 NEMA 1.18.388 37.5 57.6

XS6(X)/5 SP152X/5 1418 864 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 42.5 86.5

XS6(X)/7 SP152X/7 1669 1074 595 152 3’’ 144 6’’MS 152 NEMA 1.18.413 53 102

XS6(X)/8 SP152X/8 1814 1179 635 152 3’’ 144 6’’MS 152 NEMA 1.18.413 58 112

XS6(X)/10 SP152X/10 2074 1389 685 152 3’’ 144 6’’MS 152 NEMA 1.18.413 68 128

XS6(X)/12 SP152X/12 2324 1599 725 152 3’’ 144 6’’MS 152 NEMA 1.18.413 78 140

XS6(X)/14 SP152X/14 2584 1809 775 152 3’’ 144 6’’MS 152 NEMA 1.18.413 88 153

XS6(X)/17 SP152X/17 2999 2124 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 103 184

XS6(X)/20 SP152X/20 3404 2439 965 152 3’’ 144 6’’MS 152 NEMA 1.18.413 118 209

XS6(X)/22 SP152X/22 3524 2649 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 128 231

XS6(X)/24 SP152X/24 3914 2859 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 138 255

XS6(X)/26 SP152X/26 4204 3069 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 148 257

XS6(A)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS6(A)/2 SP151A/2 1199 590 609 148 3’’ 95 4’’CL 95 NEMA 1.18.388 24.5 44.6

XS6(A)/3 SP151A/3 1247 695 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 29 73

XS6(A)/4 SP151A/4 1395 800 595 152 3’’ 144 6’’MS 152 NEMA 1.18.413 33.5 82.5

XS6(A)/5 SP151A/5 1540 905 635 152 3’’ 144 6’’MS 152 NEMA 1.18.413 38 92

XS6(A)/6 SP151A/6 1695 1010 685 152 3’’ 144 6’’MS 152 NEMA 1.18.413 42.5 102.5

XS6(A)/7 SP151A/7 1840 1115 725 152 3’’ 144 6’’MS 152 NEMA 1.18.413 47 109

XS6(A)/8 SP151A/8 1995 1220 775 152 3’’ 144 6’’MS 152 NEMA 1.18.413 51.5 116.5

XS6(A)/9 SP151A/9 2200 1325 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 56 137

XS6(A)/10 SP151A/10 2305 1430 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 60.5 141.5

XS6(A)/11 SP151A/11 2490 1535 965 152 3’’ 144 6’’MS 152 NEMA 1.18.413 65 156

XS6(A)/12 SP151A/12 2595 1640 965 152 3’’ 144 6’’MS 152 NEMA 1.18.413 69.5 160.5

XS6(A)/13 SP151A/13 2790 1745 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 74 177

XS6(A)/14 SP151A/14 2985 1850 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 78.5 187.5

XS6(A)/15 SP151A/15 3090 1955 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 83 192

XS6(A)/16 SP151A/16 3195 2060 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 87.5 196.5

XS6(A)/17 SP151A/17 3390 2165 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 92 222

XS6(A)/18 SP151A/18 3495 2270 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 96.5 226.5

XS6(A)/19 SP151A/19 3600 2375 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 101 231

Ø 144

Ø 80

N°8-Ø 13

Ø 120

R 6

02

1

45

°

Ø d

L

H

T

Ø MAX

Ø D

24

Page 25: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

26

Dimensions and weights

XS6(B)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS6(B)/2A SP151B/2A 1199 590 609 148 3’’ 95 4’’CL 95 NEMA 1.18.388 24.5 44.6

XS6(B)/2 SP151B/2 1142 590 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 24.5 68.5

XS6(B)/3 SP151B/3 1290 695 595 152 3’’ 144 6’’MS 152 NEMA 1.18.413 29 78

XS6(B)/4 SP151B/4 1435 800 635 152 3’’ 144 6’’MS 152 NEMA 1.18.413 33.5 87.5

XS6(B)/5 SP151B/5 1590 905 685 152 3’’ 144 6’’MS 152 NEMA 1.18.413 38 98

XS6(B)/6 SP151B/6 1735 1010 725 152 3’’ 144 6’’MS 152 NEMA 1.18.413 42.5 104.5

XS6(B)/7 SP151B/7 1890 1115 775 152 3’’ 144 6’’MS 152 NEMA 1.18.413 47 112

XS6(B)/8 SP151B/8 2095 1220 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 51.5 132.5

XS6(B)/9 SP151B/9 2290 1325 965 152 3’’ 144 6’’MS 152 NEMA 1.18.413 56 147

XS6(B)/10 SP151B/10 2395 1430 965 152 3’’ 144 6’’MS 152 NEMA 1.18.413 60.5 151.5

XS6(B)/11 SP151B/11 2590 1535 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 65 168

XS6(B)/12 SP151B/12 2695 1640 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 69.5 172.5

XS6(B)/13 SP151B/13 2880 1745 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 74 183

XS6(B)/14 SP151B/14 2985 1850 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 78.5 187.5

XS6(B)/15 SP151B/15 3180 1955 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 83 228

XS6(B)/16 SP151B/16 3285 2060 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 87.5 232.5

XS6(B)/17 SP151B/17 3390 2165 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 92 237

XS6(C)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS6(C)/2 SP151C/2 1042 590 552 152 3’’ 144 6’’MS 152 NEMA 1.18.413 24.5 68.5

XS6(C)/3 SP151C/3 1340 695 635 152 3’’ 144 6’’MS 152 NEMA 1.18.413 29 83

XS6(C)/4 SP151C/4 1485 800 685 152 3’’ 144 6’’MS 152 NEMA 1.18.413 33.5 93.5

XS6(C)/5 SP151C/5 1630 905 725 152 3’’ 144 6’’MS 152 NEMA 1.18.413 38 100

XS6(C)/6A SP151C/6A 1785 1010 775 152 3’’ 144 6’’MS 152 NEMA 1.18.413 42.5 107.5

XS6(C)/6 SP151C/6 1885 1010 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 42.5 123.5

XS6(C)/7 SP151C/7 1990 1115 875 152 3’’ 144 6’’MS 152 NEMA 1.18.413 47 128

XS6(C)/8 SP151C/8 2185 1220 965 152 3’’ 144 6’’MS 152 NEMA 1.18.413 51.5 141.5

XS6(C)/9 SP151C/9 2380 1325 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 56 159

XS6(C)/10 SP151C/10 2485 1430 1055 152 3’’ 144 6’’MS 152 NEMA 1.18.413 60.5 163.5

XS6(C)/11 SP151C/11 2670 1535 1135 152 3’’ 144 6’’MS 152 NEMA 1.18.413 65 174

XS6(C)/12 SP151C/12 2865 1640 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 69.5 199.5

XS6(C)/13 SP151C/13 2970 1745 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 74 204

XS6(C)/14 SP151C/14 3075 1850 1225 152 3’’ 144 6’’MS 153 NEMA 1.18.413 78.5 208.5

6’’ XS6 Submersible

Ø 144

Ø 80

N°8-Ø 13

Ø 120

R 6

02

1

45

°

Ø d

L

H

T

Ø MAX

Ø D

25

Page 26: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

27

Applications

For deep wells with minimum diameter

of 210 mm, water supply, fountains,

irrigation, pressure boosting,

dewatering, mining & other civil/

industrial applications.

Materials

Suction support in cast iron

(EN-GJL-250).

Shaft & coupling in stainless steel

AISI 431.

Impeller & diffuser in cast iron

(EN-GJL-250).

Options:

Fully stainless steel AISI 316 (XSX8).

Fully bronze (XSB8).

Motor

Water or oiled option, 2900 rpm.

Class B insulation.

IP 68 protection.

Continuous & intermittent operation.

Complete with built-in-thermal

protection.

Connected in accordance with NEMA

standard:

6’’ NEMA MG1-18.401-18.413.

8’’ NEMA MG1-18.414-18.424.

Range: 3-37 kW, 400 V 50 Hz (other

voltages upon request).

8’’ XS8 Submersible

8’’ Semi-Axial submersible pumps

Range

XS8 A Q max: 84 m3/hr-H max: 351 mtrs.

XS8 B Q max: 126 m3/hr-H max: 351 mtrs.

XS8 C Q max: 160 m3/hr-H max: 338 mtrs.

XS8 D Q max: 228 m3/hr-H max: 252 mtrs.

Construction features

Semi-axial impellers.

5’’, 6’’ ON SB.181 & SX.181 outlet c/w

non return valve.

Pump equipped with counter thrust ring

in anti-wear resin.

Diffuser c/w wear ring in anti-wear rubber.

Driving bushings in anti-wear rubber with

metallic shell.

Components realised with particular

materials which assure in high wear

resistance.

Limitations

Maximum liquid temperature 30 °C.

Maximum immersion depth 300 m

under liquid level.

Clean non-aggressive and non-explosive

liquids, not containing solid particles

more than 3 mm.

Hydraulic performance table

XS8(A)

ModelI [A] P2** l/min 0 400 500 600 700 800 1000 1200 1400 1667

3~ 400 V [kW] [HP] m3/h 0 24 30 36 42 48 60 72 84 100

XS8(A)/1* 12.3 5.5 7.5

mw

c

27 24 23 22 22 21.5 19 17 14 10

XS8(A)/2A* 16.3 7.5 10 47 41 38 37.5 36 34 29 27 19 15

XS8(A)/2* 19.9 9.2 12,5 54 48 47 46 43 41 37 32 24 19

XS8(A)/3A* 23.8 11 15 71 62 57 54 51 48 44 38 30 21

XS8(A)/3* 27.7 13 17.5 81 72 69 66 63 60 52 45 36 29

XS8(A)/4A* 30.4 15 20 94 82 77 73 69 65 58 51 39 30

XS8(A)/4* 38 18.5 25 108 96 93 89 86 82 74 66 53 39

XS8(A)/5* 43.7 22 30 135 120 115 111 108 103 93 83 70 49

XS8(A)/6* 53.3 26 35 162 144 139 133 129 124 116 104 85 58

XS8(A)/7* 62 30 40 189 173 167 162 160 153 144 129 106 68

XS8(A)/8* 73 37 50 216 192 189 182 177 172 161 141 121 78

XS8(A)/9* 89 45 60 243 217 210 205 198 192 175 156 134 88

XS8(A)/10* 89 45 60 270 240 232 224 217 210 193 170 148 97

XS8(A)/11 111 55 75 297 264 256 248 238 231 212 184 163 107

XS8(A)/12 118 59 80 324 289 278 270 260 252 232 204 177 117

XS8(A)/13 131 67 90 351 312 302 292 282 273 251 225 192 127

* The group is also available in special version for horizontal operation

** Rated power of motor

26

Page 27: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

28

8’’ XS8 Submersible

XS8(C)

ModelI [A] P2** l/min 0 1600 1800 1900 2000 2100 2200 2400 2667

3~ 400 V [kW] [HP] m3/h 0 96 108 114 120 126 132 144 160

XS8(C)/1* 18 7.5 10

mw

c

27 18 17 16 16 15 15 14 11

XS8(C)/2B* 25 11 15 44 32 28 26 25 23 21 17

XS8(C)/2* 30.4 15 20 55 39 37 36 33 32 30 27 22

XS8(C)/3A* 38 18.5 25 76 52 48 46 44 42 39 33 25

XS8(C)/3* 45 22 30 82 58 54 52 50 48 45 39 33

XS8(C)/4A* 53.3 26 35 97 69 62 60 58 54 53 45 34

XS8(C)/4* 60.2 30 40 109 79 73 71 67 64 60 52 44

XS8(C)/5* 78 37 50 139 99 95 91 87 84 80 71 60

XS8(C)/6* 95 45 60 164 118 112 109 106 103 98 87 72

XS8(C)/7* 106 55 75 189 137 131 127 122 118 112 99 84

XS8(C)/8* 118 59 80 216 157 151 145 141 134 128 110 88

XS8(C)/9* 134 67 90 243 177 170 165 159 151 144 124 99

XS8(C)/10 152 75 100 270 196 188 183 177 168 160 138 110

XS8(C)/11 177 92 125 297 216 208 201 194 184 176 151 121

XS8(C)/12 180 92 125 324 236 227 219 212 203 192 166 132

* The group is also available in special version for horizontal operation / ** Rated power of motor

Hydraulic performance table

XS8(B)

* The group is also available in special version for horizontal operation / ** Rated power of motor

ModelI [A] P2** l/min 0 800 1000 1200 1400 1667 1800 1900 2000 2100 2250 2417

3~ 400 V [kW] [HP] m3/h 0 48 60 72 84 100 108 114 120 126 135 145

XS8(B)/1* 16.3 7.5 10

mw

c

28 25 24.5 24 23 20.5 20 18 17 15 13 8

XS8(B)/2B* 19.9 9.2 12.5 45 37 35 33 29 25.5 25 21 21

XS8(B)/2A* 23.8 11 15 50 42 40 38 36 32 30 27 25 22 17 7

XS8(B)/2* 27.7 13 17.5 57 49 47 45 43 39.5 39 36 34 30 25 18

XS8(B)/3B* 30.4 15 20 67 56 52 51 48

XS8(B)/3A* 38 18.5 25 71 61 58 54 51 44.5 42 38 36 33 26 18

XS8(B)/3* 43.7 22 30 85 74 72 69 65 59 56 53 50 46 38 28

XS8(B)/4* 53.3 26 35 114 98 94 90 84 76.5 70 66 62 56 48 36

XS8(B)/5A* 60.2 30 40 123 105 101 96 88

XS8(B)/5* 73 37 50 142 123 118 113 109 98.5 93 87 81 73 60

XS8(B)/6* 89 45 60 162 146 140 133 127 115 107 101 95 87 72 55

XS8(B)/7* 101 52 70 189 170 163 155 148 135 127 120 112 102 87 67

XS8(B)/8* 118 59 80 216 194 186 177 169 153 145 137 127 118 102 80

XS8(B)/9* 131 67 90 243 223 213 205 194 180 169 159 150 139 123 101

XS8(B)/10* 138 67 90 277 246 237 227 218 199 188 178 166 154 138 113

XS8(B)/11 166 83 113 305 271 260 249 240 220 207 196 183 170 148 118

XS8(B)/12 177 92 125 332 295 284 272 259 237 223 211 199 184 163 123

XS8(B)/13 185 92 125 360 320 307 294 283 258 244 232 218 205 180 133

XS8(D)

ModelI [A] P2** l/min 0 1800 1900 2000 2100 2200 2400 2667 2800 3000 3200 3400 3600 3800

3~ 400 V [kW] [HP] m3/h 0 108 114 120 126 132 144 160 168 180 192 204 216 228

XS8(D)/1* 21 9.2 12.5

mw

c

28 22 21 20.5 20 19 18 17 16 14 12 10 7 5

XS8(D)/2A* 30.4 15 20 47 33 32 31 30 29 27 24 22 19 16 13

XS8(D)/2 39.5 18.5 25 56 43 42 41 40 39 37 33 31 28 24 20 17 12

XS8(D)/3A* 43.7 22 30 71 51 49 48 46 45 42 37 34 30

XS8(D)/3* 60.2 30 40 86 65 63 62 60 59 55 50 47 43 38 32 26 18

XS8(D)/4* 73 37 50 115 87 85 83 81 79 74 67 63 57 49 42 34 26

XS8(D)/5* 103 52 70 140 106 103 101 98 95 92 81 78 70 61 52 41 30

XS8(D)/6* 118 59 80 168 128 125 122 119 116 109 99 93 84 75 63 51 36

XS8(D)/7* 134 67 90 196 152 147 144 140 136 128 115 109 99 85 73 60 42

XS8(D)/8 154 75 100 224 171 168 165 161 158 149 136 129 114 100 85 68 53

XS8(D)/9 177 92 125 252 194 189 185 182 178 169 156 146 131 116 100 82 64

* The group is also available in special version for horizontal operation / ** Rated power of motor

27

Page 28: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

29

8’’ XS8 Submersible

Dimensions and weights

XS8(A)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS8(A)/1 SP181A/1 1162 610 552 202 5’’ 144 6’’MS 152 NEMA 1.18.413 36.5 80.5

XS8(A)/2A SP181A/2A 1205 750 595 202 5’’ 144 6’’MS 152 NEMA 1.18.413 49 98

XS8(A)/2 SP181A/2 1385 750 635 202 5’’ 144 6’’MS 152 NEMA 1.18.413 49 103

XS8(A)/3A SP181A/3A 1575 890 685 202 5’’ 144 6’’MS 152 NEMA 1.18.413 61.5 121.5

XS8(A)/3 SP181A/3 1615 890 725 202 5’’ 144 6’’MS 152 NEMA 1.18.413 61.5 123.5

XS8(A)/4A SP181A/4A 1805 1030 775 202 5’’ 144 6’’MS 152 NEMA 1.18.413 74 139

XS8(A)/4 SP181A/4 1905 1030 875 202 5’’ 144 6’’MS 152 NEMA 1.18.413 74 155

XS8(A)/5 SP181A/5 2135 1170 965 202 5’’ 144 6’’MS 152 NEMA 1.18.413 86.5 177.5

XS8(A)/6 SP181A/6 2365 1310 1055 202 5’’ 144 6’’MS 152 NEMA 1.18.413 99 202

XS8(A)/7 SP181A/7 2585 1450 1135 202 5’’ 144 6’’MS 152 NEMA 1.18.413 111.5 220.5

XS8(A)/8 SP181A/8 2815 1590 1225 202 5’’ 144 6’’MS 153 NEMA 1.18.413 124 254

XS8(A)/9 SP181A/9 2725 1730 995 202 5’’ 192 8’’MS 201 NEMA 1.18.424 136.5 295.5

XS8(A)/10 SP181A/10 2865 1870 995 202 5’’ 192 8’’MS 201 NEMA 1.18.424 149 308

XS8(A)/11 SP181A/11 3075 2010 1065 202 5’’ 192 8’’MS 201 NEMA 1.18.424 161.5 333.5

XS8(A)/12 SP181A/12 3285 2150 1135 202 5’’ 192 8’’MS 201 NEMA 1.18.424 174 362

XS8(A)/13 SP181A/13 3525 2290 1235 202 5’’ 192 8’’MS 201 NEMA 1.18.424 186.5 394.5

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS8(B)/1 SP181B/1 1205 610 595 202 5’’ 144 6’’MS 152 NEMA 1.18.413 37 86

XS8(B)/2B SP181B/2B 1385 750 635 202 5’’ 144 6’’MS 152 NEMA 1.18.413 48.5 102.5

XS8(B)/2A SP181B/2A 1435 750 685 202 5’’ 144 6’’MS 152 NEMA 1.18.413 48.5 108.5

XS8(B)/2 SP181B/2 1475 750 725 202 5’’ 144 6’’MS 152 NEMA 1.18.413 48.5 110.5

XS8(B)/3B SP181B/3B 1665 890 775 202 5’’ 144 6’’MS 152 NEMA 1.18.413 60 125

XS8(B)/3A SP181B/3A 1765 890 875 202 5’’ 144 6’’MS 152 NEMA 1.18.413 60 141

XS8(B)/3 SP181B/3 1855 890 965 202 5’’ 144 6’’MS 152 NEMA 1.18.413 60 151

XS8(B)/4 SP181B/4 2085 1030 1055 202 5’’ 144 6’’MS 152 NEMA 1.18.413 71.5 174.5

XS8(B)/5A SP181B/5A 2305 1170 1135 202 5’’ 144 6’’MS 152 NEMA 1.18.413 83 192

XS8(B)/5 SP181B/5 2395 1170 1225 202 5’’ 144 6’’MS 153 NEMA 1.18.413 83 213

XS8(B)/6 SP181B/6 2305 1310 995 202 5’’ 192 6’’MS 201 NEMA 1.18.424 94.5 253.5

XS8(B)/7 SP181B/7 2515 1450 1065 202 5’’ 192 6’’MS 201 NEMA 1.18.424 106 278

XS8(B)/8 SP181B/8 2725 1590 1435 202 5’’ 192 6’’MS 201 NEMA 1.18.424 117.5 305.5

XS8(B)/9 SP181B/9 2965 1730 1235 202 5’’ 192 6’’MS 201 NEMA 1.18.424 129 337

XS8(B)/10 SP181B/10 3105 1870 1235 202 5’’ 192 6’’MS 201 NEMA 1.18.424 140.5 343.5

XS8(B)/11 SP181B/11 3425 2010 1415 202 5’’ 192 6’’MS 201 NEMA 1.18.424 152 389

XS8(B)/12 SP181B/12 3645 2150 1495 202 5’’ 192 6’’MS 201 NEMA 1.18.424 163.5 414.5

XS8(B)/13 SP181B/13 3785 2290 1495 202 5’’ 192 6’’MS 201 NEMA 1.18.424 175 426

XS8(B)

Ø 192

Ø 125

N°8-Ø 15

Ø 170

R 8

03

0

45

°

Ø d

L

H

T

Ø MAX

Ø D

28

Page 29: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

30

8’’ XS8 Submersible

Dimensions and weights

XS8(C)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS8(C)/1 SP181C/1 1205 610 595 202 5’’ 144 6’’MS 152 NEMA 1.18.413 38.5 87.5

XS8(C)/2B SP181C/2B 1435 750 685 202 5’’ 144 6’’MS 152 NEMA 1.18.413 50 110

XS8(C)/2 SP181C/2 1525 750 775 202 5’’ 144 6’’MS 152 NEMA 1.18.413 50 115

XS8(C)/3A SP181C/3A 1765 890 875 202 5’’ 144 6’’MS 152 NEMA 1.18.413 61.5 142.5

XS8(C)/3 SP181C/3 1855 890 965 202 5’’ 144 6’’MS 152 NEMA 1.18.413 61.5 152.5

XS8(C)/4A SP181C/4A 2085 1030 1055 202 5’’ 144 6’’MS 152 NEMA 1.18.413 73 176

XS8(C)/4 SP181C/4 2165 1030 1135 202 5’’ 144 6’’MS 152 NEMA 1.18.413 73 182

XS8(C)/5 SP181C/5 2395 1170 1225 202 5’’ 144 6’’MS 153 NEMA 1.18.413 84.5 214.5

XS8(C)/6 SP181C/6 2305 1310 995 202 5’’ 192 8’’MS 201 NEMA 1.18.424 96 255

XS8(C)/7 SP181C/7 2515 1450 1065 202 5’’ 192 8’’MS 201 NEMA 1.18.424 107.5 279.5

XS8(C)/8 SP181C/8 2725 1590 1135 202 5’’ 192 8’’MS 201 NEMA 1.18.424 119 307

XS8(C)/9 SP181C/9 2965 1730 1235 202 5’’ 192 8’’MS 201 NEMA 1.18.424 130.5 333.5

XS8(C)/10 SP181C/10 3205 1870 1335 202 5’’ 192 8’’MS 201 NEMA 1.18.424 142 363

XS8(C)/11 SP181C/11 3505 2010 1495 202 5’’ 192 8’’MS 201 NEMA 1.18.424 153.5 374.5

XS8(C)/12 SP181C/12 3645 2150 1495 202 5’’ 192 8’’MS 201 NEMA 1.18.424 165 416

XS8(D)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS8(D)/1 SP181D/1 1245 610 635 202 5’’ 144 6’’MS 152 NEMA 1.18.413 39 93

XS8(D)/2A SP181D/2A 1525 750 775 202 5’’ 144 6’’MS 152 NEMA 1.18.413 50.5 115.5

XS8(D)/2 SP181D/2 1625 750 875 202 5’’ 144 6’’MS 152 NEMA 1.18.413 50.5 131.5

XS8(D)/3A SP181D/3A 1855 890 965 202 5’’ 144 6’’MS 152 NEMA 1.18.413 62 153

XS8(D)/3 SP181D/3 2025 890 1135 202 5’’ 144 6’’MS 152 NEMA 1.18.413 62 171

XS8(D)/4 SP181D/4 2255 1030 1225 202 5’’ 144 6’’MS 153 NEMA 1.18.413 73.5 203.5

XS8(D)/5 SP181D/5 2235 1170 1065 202 5’’ 192 8’’MS 201 NEMA 1.18.424 85 257

XS8(D)/6 SP181D/6 2445 1310 1135 202 5’’ 192 8’’MS 201 NEMA 1.18.424 96.5 284.5

XS8(D)/7 SP181D/7 2685 1450 1235 202 5’’ 192 8’’MS 201 NEMA 1.18.424 108 311

XS8(D)/8 SP181D/8 2925 1590 1335 202 5’’ 192 8’’MS 201 NEMA 1.18.424 119.5 340.5

XS8(D)/9 SP181D/9 3225 1730 1495 202 5’’ 192 8’’MS 201 NEMA 1.18.424 131 382

Ø 192

Ø 125

N°8-Ø 15

Ø 170

R 8

03

0

45

°

Ø d

L

H

T

Ø MAX

Ø D

29

Page 30: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

31

Applications

For deep wells with minimum diameter

of 264 mm, water supply,

fountains, irrigation, pressure

boosting, dewatering, mining &

other civil/industrial applications.

Materials

Suction support in cast iron

(EN-GJL-250).

Shaft & coupling in stainless steel

AISI 431.

Impeller & diffuser in cast iron

(EN-GJL-250).

Options:

Fully stainless steel AISI 316 (XSX10).

Fully bronze (XSB10).

Motor

Water or oiled option, 2900 rpm.

Class B insulation.

IP 68 protection.

Continuous & intermittent operation.

Complete with built-in-thermal

protection.

Connected in accordance with

NEMA standard:

8’’or 10’’ NEMA MG1-18.414-18.424

Range: 22-170 kW, 400 V 50 Hz

(other voltages upon request).

10’’ XS10 Submersible

10’’ Semi-Axial submersible pumps

Range

XS10 2A Q max; 280 m3/hr-H max:

2881 mtrs.

XS10 2B Q max: 400 m3/hr-H max:

2401 mtrs.

XS10 2A Q max: 220 m3/hr-H max:

388 mtrs.

Construction features

Semi-axial impellers.

6’’ outlet c/w non return valve.

Pump equipped with counter thrust

ring in anti-wear resin.

Diffuser c/w wear ring in anti-wear

rubber.

Driving bushings in anti-wear rubber

with metallic shell.

Components realised with particular

materials which assure in high wear

resistance.

Limitations

Maximum liquid temperature 30 °C.

Maximum immersion depth 300 m

under liquid level.

Clean non-aggressive and non-explosive

liquids, not containing solid particles

more than 3 mm.

Hydraulic performance table

XS10(A)

ModelI [A] P2** l/min 0 1667 2000 2333 2500 2667 2833 3000 3167 3333 3500 3667

3~ 400 V [kW] [HP] m3/h 0 100 120 140 150 160 170 180 190 200 210 220

XS10(A)/1A* 47 22 30

mw

c

48 41 39 38 37 35 33 31 28 26 24 20

XS10(A)/1* 54 26 35 53 45 43 42 41 40 39 37 35 33 31 29

XS10(A)/2B* 74 37 50 82 67 64 60 57 53 49 46 40 33 28

XS10(A)/2A* 89 45 60 97 82 79 75 74 70 67 62 57 52 49 44

XS10(A)/2* 103 52 70 106 91 87 85 83 81 78 74 70 66 62 58

XS10(A)/3B* 103 52 70 123 100 96 90 85.5 80 73.5 69 60 50 42

XS10(A)/3A* 131 67 90 145.5 123 118.5 112.5 111 105 100.5 93 85.5 78 73.5 66

XS10(A)/3* 147 75 100 159 136.5 130.5 127.5 124.5 121.5 117 111 105 99 93 87

XS10(A)/5B* 166 83 113 205 167.5 160 150 142.5 132.5 122.5 111.5 100 86.5 70

XS10(A)/4A* 177 92 125 194 164 158 150 148 140 134 124 114 104 98 88

XS10(A)/4* 200 110 150 212 182 174 168 166 160.5 156 148 140 132 124 116

XS10(A)/5A* 200 110 150 242.5 205 197.5 187.5 185 173.5 167.5 155 142.5 133.9 122.5 110

XS10(A)/5* 245 132 180 265 227.5 220 211 207.5 198.6 195 185 175 165 155 145

XS10(A)/6A* 245 132 180 291 246 237 225 222 210 201 188 171 162 147 132

XS10(A)/6 270 150 200 318 273 261 253 249 239 234 222 210 200 186 174

XS10(A)/7A 270 150 200 339.5 287 276.5 263 259 245 235 217 200 186 172 154

XS10(A)/7 325 185 250 371 319 309 296 291 282 273 259 245 233 217 203

XS10(A)/8A 308 170 230 388 328 316 300 296 280 268 248 228 215 196 176

* The group is also available in special version for horizontal operation

** Rated power of motor

30

Page 31: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

32

10’’ XS10 Submersible

Hydraulic performance table

XS10(2A)

ModelI [A] P2** l/min 0 1667 2000 2667 3000 3333 4000 4667

3~ 400 V [kW] [HP] m3/h 0 100 120 160 180 200 240 280

XS10(2A)/1* 61 30 40

mw

c

50 43.5 40.5 37.5 36 34 30 24

XS10(2A)/2A* 79 37 50 79 67 63 56 54 50 42 33

XS10(2A)/2* 118 59 80 95 82 80 75 72 68 60 48

XS10(2A)/3A* 118 59 80 119 100 96 87 82 77 64 47

XS10(2A)/3B* 133 67 90 127 110 103 95 91 86 76 61

XS10(2A)/3* 165 83 113 146 122 117 109 105 102 90 72

XS10(2A)/4B* 180 92 125 174 147 141 130 125 119 104 86

XS10(2A)/4* 210 110 150 190 167 162 150 144 140 124 100

XS10(2A)/6C 210 110 150 228 197 189 170 162 152 127 93

XS10(2A)/5* 250 132 180 261 208 200 187 181 172 155 128

XS10(2A)/6 308 170 230 288 256 247 228 220 212 187 144

* The group is also available in special version for horizontal operation

** Rated power of motor

XS10(2B)

ModelI [A] P2** l/min 0 3000 3333 4000 4667 5000 5333 5667 6000 6333 6667

3~ 400 V [kW] [HP] m3/h 0 180 200 240 280 300 320 340 360 380 400

XS10(2B)/1B* 54 26 35

mw

c

41 28.5 27.5 25.5 23.5 22.5 19

XS10(2B)/1C* 66 30 40 45 32 31 29 27 25 23 21 18 15 12

XS10(2B)/1* 74 37 50 51 37.5 36 33 30 29 27 25 24 19 16

XS10(2B)/2B* 101 52 70 80 61 58 55 48 43 40 34 29 23 16

XS10(2B)/2C* 118 59 80 87 68 65 61 56 52 48 44 38 33 26

XS10(2B)/2* 150 75 100 98 73 72 68 63 60 56 52 47 42 35

XS10(2B)/3B* 150 75 100 120 92 88 83 72 65 60 52 44 35 25

XS10(2B)/3C* 177 92 125 131 102 98 92 85 79 73 67 58 50 40

XS10(2B)/3* 200 110 150 144 115 111 103 96 93 87 81 74 66 56

XS10(2B)/5A* 204 110 150 184 142 135 125 105 95 87 68 56 42 25

XS10(2B)/4* 270 150 200 195 154 150 140 131 123 114 107 98 92 81

XS10(2B)/5B* 246 132 180 205 160 153 144 127 116 105 92 80 66 50

XS10(2B)/6A* 245 132 180 218 170 163 153 126 114 104 82 67 50 30

XS10(2B)/5* 308 170 230 240 192 187 175 163 153 142 133 122 115 101

* The group is also available in special version for horizontal operation

** Rated power of motor

XS10(2BX)

ModelI [A] P2** l/min 0 3000 3333 4000 4667 5000 5333 5667 6000 6333

3~ 400 V [kW] [HP] m3/h 0 180 200 240 280 300 320 340 360 380

XS10(2BX)/1B* 47 22 30

mw

c

38 27 26 22.5 17.5 14 10

XS10(2BX)/1C* 54 26 35 42 30.5 30 27.5 23.5 21 17.5 14.5 11

XS10(2BX)/1* 74 37 50 47 39 38 35.5 32.5 30.5 28 25.5 22 18.5

XS10(2BX)/2B* 89 45 60 76 54 52 45 35 28 20

XS10(2BX)/2C* 111 55 75 84 63 60 56 48 43 37 33 26

XXS10(2BX)/2* 150 75 100 94 78 76 72 66 62 56 52 44 38

XS10(2BX)/3C* 166 83 113 126 92 90 83 71 63 53 44 33

XS10(2BX)/3* 210 110 150 141 117 114 106 97 91 84 75 66 55

XS10(2BX)/4* 270 150 200 188 156 152 144 132 124 112 104 88 76

XS10(2BX)/5C* 245 132 180 210 169 164 151 131 117 103 88 70 52

XS10(2BX)/5* 308 170 230 236 195 191 178 161 151 140 127 113 92

* The group is also available in special version for horizontal operation

** Rated power of motor

31

Page 32: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

33

10’’ XS10 Submersible

Dimensions and weights

XS10(2B)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS10(2B)/1B SP252B/1B 1498 733 845 255 6’’ 192 8’’MS 201 NEMA 1.18.424 67 193

XS10(2B)/1C SP252B/1C 1578 733 845 255 6’’ 192 8’’MS 201 NEMA 1.18.424 67 198

XS10(2B)/1 SP252B/1 1658 733 925 255 6’’ 192 8’’MS 201 NEMA 1.18.424 67 212

XS10(2B)/2B SP252B/2B 1981 916 1065 255 6’’ 192 8’’MS 201 NEMA 1.18.424 88.5 260.5

XS10(2B)/2C SP252B/2C 1911 916 1135 255 6’’ 192 8’’MS 201 NEMA 1.18.424 88.5 272.5

XS10(2B)/2 SP252B/2 2251 916 1335 255 6’’ 192 8’’MS 201 NEMA 1.18.424 88.5 311.5

XS10(2B)/3B SP252B/3B 2434 1099 1335 255 6’’ 192 8’’MS 201 NEMA 1.18.424 110 333

XS10(2B)/3C SP252B/3C 2594 1099 1495 255 6’’ 192 8’’MS 201 NEMA 1.18.424 110 365

XS10(2B)/3 SP252B/3 2529 1099 1430 255 6’’ 192 10’’MS 251 110 474

XS10(2B)/5A SP252B/5A 2895 1465 1430 255 6’’ 238 10’’MS 251 153 517

XS10(2B)/4 SP252B/4 2492 1282 1660 255 6’’ 238 10’’MS 251 131.5 551.5

XS10(2B)/5B SP252B/5B 3035 1465 1570 255 6’’ 238 10’’MS 251 153 551

XS10(2B)/6A SP252B/6A 3218 1648 1570 255 6’’ 238 10’’MS 251 173.5 571.5

XS10(2B)/5 SP252B/5 3265 1465 1800 255 6’’ 238 10’’MS 251 153 607

XS10(2BX)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS10(2BX)/1B XSP252B/1B 1498 733 765 255 6’’ 192 8’’MS 201 NEMA 1.18.424 67 177

XS10(2BX)/1C XSP252B/1C 1578 733 845 255 6’’ 192 8’’MS 201 NEMA 1.18.424 67 193

XS10(2BX)/1 XSP252B/1 1658 733 925 255 6’’ 192 8’’MS 201 NEMA 1.18.424 67 209

XS10(2BX)/2B XSP252B/2B 1911 916 995 255 6’’ 192 8’’MS 201 NEMA 1.18.424 88.5 244.5

XS10(2BX)/2C XSP252B/2C 1981 916 1065 255 6’’ 192 8’’MS 201 NEMA 1.18.424 88.5 258.5

XS10(2BX)/2 XSP252B/2 2151 916 1235 255 6’’ 192 8’’MS 201 NEMA 1.18.424 88.5 291.5

XS10(2BX)/3C XSP252B/3C 2514 1099 1415 255 6’’ 192 8’’MS 201 NEMA 1.18.424 110 333

XS10(2BX)/3 XSP252B/3 2529 1099 1430 255 6’’ 238 10’’MS 251 110 474

XS10(2BX)/4 XSP252B/4 3125 1465 1660 255 6’’ 238 10’’MS 251 131 551

XS10(2BX)/5C XSP252B/5C 3035 1465 1570 255 6’’ 238 10’’MS 251 153 551

XS10(2BX)/5 XSP252B/5 3265 1465 1800 255 6’’ 238 10’’MS 251 153 607

Ø 230

Ø 150

N°8-Ø 18

Ø 200

R 9

63

5

45

°

Ø d

L

H

T

Ø MAX

Ø D

32

Page 33: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

34

10’’ XS10 Submersible

Dimensions and weights

XS10(A)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS10(A)/1A SP253A/1A 1447 682 765 255 6’’ 192 MS201 NEMA 1.18.424 66 176

XS10(A)/1 SP253A/1 1527 682 845 255 6’’ 192 MS201 NEMA 1.18.424 66 192

XS10(A)/2B SP253A/2B 1804 879 925 255 6’’ 192 MS201 NEMA 1.18.424 87.5 229.5

XS10(A)/2A SP253A/2A 1874 879 995 255 6’’ 192 MS201 NEMA 1.18.424 87.5 243.5

XS10(A)/2 SP253A/2 1962 897 1065 255 6’’ 192 MS201 NEMA 1.18.424 87.5 257.5

XS10(A)/3B SP253A/3B 2177 1112 1065 255 6’’ 192 MS201 NEMA 1.18.424 109 279

XS10(A)/3A SP253A/3A 2347 1112 1235 255 6’’ 192 MS201 NEMA 1.18.424 109 313

XS10(A)/3 SP253A/3 2447 1112 1335 255 6’’ 192 MS201 NEMA 1.18.424 109 332

XS10(A)/5B SP253A/5B 2957 1542 1415 255 6’’ 192 MS201 NEMA 1.18.424 130.5 369.5

XS10(A)/4A SP253A/4A 2822 1327 1495 255 6’’ 192 MS201 NEMA 1.18.424 130.5 385.5

XS10(A)/4 SP253A/4 2757 1327 1430 255 6’’ 255 MS251 130.5 494.5

XS10(A)/5A SP253A/5A 2972 1542 1430 255 6’’ 255 MS251 152 516

XS10(A)/5 SP253A/5 3112 1542 1570 255 6’’ 255 MS251 152 550

XS10(A)/6A SP253A/6A 3327 1757 1570 255 6’’ 255 MS251 173.5 571.5

XS10(A)/6 SP253A/6 3417 1757 1660 255 6’’ 255 MS251 173.5 593.5

XS10(A)/7A SP253A/7A 3632 1972 1660 255 6’’ 255 MS251 195 615

XS10(A)/7 SP253A/7 3882 1972 1910 255 6’’ 255 MS251 195 676

XS10(A)/8A SP253A/8A 3987 2187 1800 255 6’’ 255 MS251 216.5 670.5

XS10(2A)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS10(2A)/1 SP252A/1 1578 733 845 255 6’’ 192 8’’MS 201 NEMA 1.18.424 66 197

XS10(2A)/2A SP252A/2A 1841 916 925 255 6’’ 192 8’’MS 201 NEMA 1.18.424 87.5 232.5

XS10(2A)/2 SP252A/2 2051 916 1135 255 6’’ 192 8’’MS 201 NEMA 1.18.424 87.5 275.5

XS10(2A)/3A SP252A/3A 2234 1099 1135 255 6’’ 192 8’’MS 201 NEMA 1.18.424 109 297

XS10(2A)/3B SP252A/3B 2334 1099 1235 255 6’’ 192 8’’MS 201 NEMA 1.18.424 109 312

XS10(2A)/3 SP252A/3 2514 1099 1415 255 6’’ 192 8’’MS 201 NEMA 1.18.424 109 348

XS10(2A)/4B SP252A/4B 2777 1282 1495 255 6’’ 192 8’’MS 201 NEMA 1.18.424 130.5 381.5

XS10(2A)/4 SP252A/4 2712 1282 1430 255 6’’ 238 10’’MS 251 130.5 485

XS10(2A)/6C SP252A/6C 3078 1648 1430 255 6’’ 238 10’’MS 251 173.5 528.5

XS10(2A)/5 SP252A/5 3035 1465 1570 255 6’’ 238 10’’MS 251 152 554

XS10(2A)/6 SP252A/6 3448 1648 1800 255 6’’ 238 10’’MS 251 173.5 627

Ø 230

Ø 150

N°8-Ø 18

Ø 200

R 9

63

5

45

°

Ø d

L

H

T

Ø MAX

Ø D

33

Page 34: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

35

Hydraulic performance table

Applications

For deep wells with minimum diameter

of 310 mm, water supply, fountains,

irrigation, pressure boosting, dewatering,

mining & other civil/industrial

applications.

Materials

Suction support in cast iron

(EN-GJL-250).

Shaft & coupling in stainless steel

AISI 431.

Impeller & diffuser in cast iron

(EN-GJL-250).

Options:

Fully stainless steel AISI 316 (XSX12).

Fully bronze (XSB12).

Motor

Water or oiled option, 2900 rpm.

Class B insulation.

IP 68 protection.

Continuous & intermittent operation.

Complete with built-in-thermal

protection.

Connected in accordance with NEMA

standard:

8’’,10’’or 12’’ NEMA MG1-18.414-18.424

Range: 37-300 kW, 400 V 50Hz (other

voltages upon request).

12’’ XS12 Submersible

12’’ Semi-Axial submersible pumps

Range

XS12 A Q max; 525 m3/hr-H max:

384 mtrs.

XS12 B Q max: 575 m3/hr-H max:

312 mtrs.

Construction features

Semi-axial impellers.

8’’ flanged outlet c/w non return valve.

Pump equipped with counter thrust

ring in anti-wear resin.

Diffuser c/w wear ring in anti-wear

rubber.

Driving bushings in anti-wear rubber

with metallic shell.

Components realised with particular

materials which assure in high wear

resistance.

Limitations

Maximum liquid temperature 30 °C.

Maximum immersion depth 300 m

under liquid level.

Clean non-aggressive and non-explosive

liquids, not containing solid particles

more than 3 mm.

XS12(A)

ModelI [A] P2** l/min 0 3333 3750 4167 4583 5000 5417 5833 6250 6667 7083 7500 7917 8333 8750

3~ 400 V [kW] [HP] m3/h 0 200 225 250 275 300 325 350 375 400 425 450 475 500 525

XS12(A)/1B* 74 37 50

mw

c

50 36 34 33 31 30 30 28 26 23 21 19 16

XS12(A)/1A* 89 45 60 51 38.5 38 37 36.5 36 35 34 32.5 29 28 25 23 19

XS12(A)/1* 131 67 90 59 45.5 44.5 44 43.5 43 41.5 40 38 36 34 32 28 25.5 16.5

XS12(A)/2B* 147 75 100 95 69 65.5 63 61 59 57 53 50 45 40 35 30 22 13

XS12(A)/2A* 177 92 125 101 80 77 74 71 70 69 66 62 58 54 49.5 44.5 37.5 32.5

XS12(A)/2* 245 132 180 116 100 98.5 96 95 93.5 93.5 91.3 87.6 83.5 80 73 68 60 53

XS12(A)/3B* 215 110 150 150 108 102 99 94 91 88 84 78 69 63 57 48 39 30

XS12(A)/4B* 280 150 200 195 142 137 130 124 120 118 112 104 96 86 76 66 56 40

XS12(A)/4A* 340 185 250 190 164 160 152 149 144 142 136 129 121 110 103 93 83 68

XS12(A)/4 470 260 350 232 200 197 192 190 187 187 182.6 175.2 167 160 146 136 120 106

XS12(A)/5B* 350 185 250 252 181 175 165 157 153 152 144 135 124 111 98 81 70 49

XS12(A)/6B* 413 220 300 288 221 212 201 189 185 183 174 161 148 134 117 105 86 69

XS12(A)/7B 480 260 350 336 258 247 235 221 216 213 203 188 173 156 137 122 100 80

XS12(A)/8B 545 300 400 384 294 282 268 252.5 247 243 232 215 198 178 156.5 139.5 114 91

* The group is also available in special version for horizontal operation

** Rated power of motor

34

Page 35: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

36

12’’ XS12 Submersible

Hydraulic performance table

XS12(B)

ModelI [A] P2** l/min 0 4167 4583 5000 5417 5833 6250 6667 7083 7500 7917 8333 8750 9167 9583

3~ 400 V [kW] [HP] m3/h 0 250 275 300 325 350 375 400 425 450 475 500 525 550 575

XS12(B)/1C* 74 37 50

mw

c

46.5 31.5 30.5 29.5 28.5 27 24.5 23 20.5 18 15.6 12.8 9 6

XS12(B)/1B* 89 45 60 48 33 32.5 32 31 29 27 24.5 22 19 16 12.5 10

XS12(B)/1A* 103 52 70 53 37 36.5 35.5 34.5 33 31.5 29 27 24.5 21 18 16.5 9.5

XS12(B)/1* 131 67 90 57 47 45 44 43.5 42 40.5 38 36 33.5 31 28 25 20

XS12(B)/2C* 147 75 100 90 63 61 60 58 54 50 46 41 35 29 23.5 16 7

XS12(B)/2B* 177 92 125 99 70 67.5 67 65 62 58.5 54.5 49.5 45 40 33.5

XS12(B)/2A* 203 110 150 109 85 81 79 77 75 71 67 63 55 50 45 38 30

XS12(B)/3C* 206 110 150 135 94.5 91.5 90 87 81 75 69 61.5 52.5 43.5 35.2 24 10.5

XS12(B)/2* 245 132 180 114 94 90.5 88.5 87 84.5 81 76 72 67 62 56 50 40.5

XS12(B)/3B* 245 132 180 142 107 102 100 97 92 87 82 75 68 61 51 42 31

XS12(B)/3A* 274 150 200 164 127 121 119 116 112 106 101 94 83 75 67 57.5 45.5

XS12(B)/4B* 325 185 250 189.5 143 136 133 129 123 115.5 109 100 90.5 81 68.5 56 41

XS12(B)/5C* 325 185 250 231 167 156 152 148 141 130 120 108 95 83 71 56 41

XS12(B)/4A* 390 220 300 206 164 157 152 148 141 133 123 115 104 96 84 71 54

XS12(B)/6C* 390 220 300 277 200 187 182 178 169 156 144 130 114 100 85 67 49

XS12(B)/4 470 260 350 228 188 181 177 174 169 162 152 144 134 124 112 100 81

XS12(B)/5A 470 260 350 257 205 196 190.5 184.5 176 166 154 144 130 120 104.5 89 68

XS12(B)/7C 470 260 350 324 234 219 213 208 198 182 168 152 133 117 100 79 58

XS12(B)/6A 545 300 400 312 252 241 233.5 228 220 209 195.5 182 166 152.5 135 118 97 71

XS12(2AX)

ModelI [A] P2** l/min 0 3333 3750 4167 4583 5000 5417 5833 6250 6667 7083 7500

3~ 400 V [kW] [HP] m3/h 0 200 225 250 275 300 325 350 375 400 425 450

XS12(2AX)/1B* 74 37 50

mw

c

50 36 34 33 31 30 30 28 26 23 21 19

XS12(2AX)/1A* 89 45 60 51 38.5 38 37 36.5 36 35 34 32.5 29 28 25

XS12(2AX)/1* 118 60 80 59 45.5 44.5 44 43.5 43 41.5 40 38 36 34 32

XS12(2AX)/2B* 147 75 100 95 69 65.5 63 61 59 57 53 50 45 40 35

XS12(2AX)/2A* 177 92 125 101 80 77 74 71 70 69 66 62 58 54 49.5

XS12(2AX)/2* 245 132 180 116 100 98.5 96 95 93.5 93.5 91.3 87.6 83.5 80 73

XS12(2AX)/3B* 215 110 150 150 108 102 99 94 91 88 84 78 69 63 57

XS12(2AX)/4B* 280 150 200 195 142 137 130 124 120 118 112 104 96 86 76

XS12(2AX)/4A* 340 185 250 190 164 160 152 149 144 142 136 129 121 110 103

XS12(2AX)/4 470 260 350 232 200 197 192 190 187 187 182.6 175.2 167 160 146

XS12(2AX)/5B* 350 185 250 252 181 175 165 157 153 152 144 135 124 111 98

XS12(2AX)/6B* 413 220 300 288 221 212 201 189 185 183 174 161 148 134 117

XS12(2AX)/7B 480 260 350 336 258 247 235 221 216 213 203 188 173 156 137

XS12(2AX)/8B 545 300 400 384 294 282 268 252.5 247 243 232 215 198 178 156.5

* The group is also available in special version for horizontal operation

** Rated power of motor

* The group is also available in special version for horizontal operation

** Rated power of motor

35

Page 36: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

37

12’’ XS12 Submersible

* The group is also available in special version for horizontal operation

** Rated power of motor

* The group is also available in special version for horizontal operation

** Rated power of motor

Hydraulic performance table

XS12(2BX)

ModelI [A] P2** l/min 0 4167 4583 5000 5417 5833 6250 6667 7083 7500 7917 8333

3~ 400 V [kW] [HP] m3/h 0 250 275 300 325 350 375 400 425 450 475 500

XS12(2BX)/1C* 74 37 50

mw

c

46.5 31.5 30.5 29.5 28.5 27 24.5 23 20.5 18 15.6 12.8

XS12(2BX)/1B* 89 45 60 48 33 32.5 32 31 29 27 24.5 22 19 16 12.5

XS12(2BX)/1A* 103 52 70 53 37 36.5 35.5 34.5 33 31.5 29 27 24.5 21 18

XS12(2BX)/1* 131 67 90 57 47 45 44 43.5 42 40.5 38 36 33.5 31 28

XS12(2BX)/2C* 147 75 100 90 63 61 60 58 54 50 46 41 35 29 23.5

XS12(2BX)/2B* 177 92 125 99 70 67.5 67 65 62 58.5 54.5 49.5 45 40 33.5

XS12(2BX)/2A* 203 110 150 109 85 81 79 77 75 71 67 63 55 50 45

XS12(2BX)/3C* 206 110 150 135 94.5 91.5 90 87 81 75 69 61.5 52.5 43.5 35.2

XS12(2BX)/2* 245 132 180 114 94 90.5 88.5 87 84.5 81 76 72 67 62 56

XS12(2BX)/3B* 245 132 180 142 107 102 100 97 92 87 82 75 68 61 51

XS12(2BX)/3A* 274 150 200 164 127 121 119 116 112 106 101 94 83 75 67

XS12(2BX)/4B* 325 185 250 189.5 143 136 133 129 123 115.5 109 100 90.5 81 68.5

XS12(2BX)/5C* 325 185 250 231 167 156 152 148 141 130 120 108 95 83 71

XS12(2BX)/4A* 390 220 300 206 164 157 152 148 141 133 123 115 104 96 84

XS12(2BX)/6C* 390 220 300 277 200 187 182 178 169 156 144 130 114 100 85

XS12(2BX)/4 470 260 350 228 188 181 177 174 169 162 152 144 134 124 112

XS12(2BX)/5A 470 260 350 257 205 196 190.5 184.5 176 166 154 144 130 120 104.5

XS12(2BX)/7C 470 260 350 324 234 219 213 208 198 182 168 152 133 117 100

XS12(2BX)/6A 545 300 400 312 252 241 233.5 228 220 209 195.5 182 166 152.5 135

36

Page 37: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

38

12’’ XS12 Submersible

Dimensions and weights

XS12(A)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS12(A)/1B SP302A/1B 1880 955 925 301 8’’ 192 8’’ MS 201 NEMA 1.18.424 130 275

XS12(A)/1A SP302A/1A 1950 955 995 301 8’’ 192 8’’ MS 201 NEMA 1.18.424 130 289

XS12(A)/1 SP302A/1 2190 955 1235 301 8’’ 192 8’’ MS 201 NEMA 1.18.424 130 333

XS12(A)/2B SP302A/2B 2485 1150 1335 301 8’’ 192 8’’ MS 201 NEMA 1.18.424 165 386

XS12(A)/2A SP302A/2A 2645 1150 1495 301 8’’ 192 8’’ MS 201 NEMA 1.18.424 165 416

XS12(A)/2 SP302A/2 2720 1150 1570 301 8’’ 238 10’’ MS 251 165 567

XS12(A)/3B SP302A/3B 2775 1345 1430 301 8’’ 238 10’’ MS 251 200 555

XS12(A)/4B SP302A/4B 3200 1540 1660 301 8’’ 238 10’’ MS 251 235 670

XS12(A)/4A SP302A/4A 3450 1540 1910 301 8’’ 238 10’’ MS 251 235 757

XS12(A)/4 SP302A/4 3448 1540 1908 301 8’’ 238 12’’ MS 300 235 932

XS12(A)/5B SP302A/5B 3645 1735 1910 301 8’’ 238 10’’ MS 251 270 792

XS12(A)/6B SP302A/6B 3688 1930 1758 301 8’’ 288 12’’ MS 300 305 935

XS12(A)/7B SP302A/7B 4033 2125 1908 301 8’’ 288 12’’ MS 300 340 1037

XS12(A)/8B SP302A/8B 4378 2320 2058 301 8’’ 288 12’’ MS 300 375 1140

XS12(B)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS12(B)/1C SP302B/1C 1880 955 925 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 275

XS12(B)/1B SP302B/1B 1950 955 995 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 289

XS12(B)/1A SP302B/1A 2020 955 1065 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 302

XS12(B)/1 SP302B/1 2190 955 1235 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 333

XS12(B)/2C SP302B/2C 2485 1150 1335 301 8’’ 192 8’’MS 201 NEMA 1.18.424 165 386

XS12(B)/2B SP302B/2B 2645 1150 1495 301 8’’ 192 8’’MS 201 NEMA 1.18.424 165 416

XS12(B)/2A SP302B/2A 2580 1150 1430 301 8’’ 238 10’’MS 251 165 520

XS12(B)/3C SP302B/3C 2775 1345 1430 301 8’’ 238 10’’MS 251 200 555

XS12(B)/2 SP302B/2 2720 1150 1570 301 8’’ 238 10’’MS 251 165 567

XS12(B)/3B SP302B/3B 2915 1345 1570 301 8’’ 238 10’’MS 251 200 602

XS12(B)/3A SP302B/3A 3005 1345 1660 301 8’’ 238 10’’MS 251 200 635

XS12(B)/4B SP302B/4B 3450 1540 1910 301 8’’ 238 10’’MS 251 235 757

XS12(B)/5C SP302B/5C 3645 1735 1910 301 8’’ 238 10’’MS 251 270 792

XS12(B)/4A SP302B/4A 3298 1540 1758 301 8’’ 288 12’’MS 300 235 865

XS12(B)/6C SP302B/6C 3688 1930 1758 301 8’’ 288 12’’MS 300 305 935

XS12(B)/4 SP302B/4 3488 1540 1908 301 8’’ 288 12’’MS 300 235 932

XS12(B)/5A SP302B/5A 3643 1735 1908 301 8’’ 288 12’’MS 300 270 967

XS12(B)/7C SP302B/7C 4033 2125 1908 301 8’’ 288 12’’MS 300 340 1037

XS12(B)/6A SP302B/6A 3988 1930 2058 301 8’’ 288 12’’MS 300 305 1070

M 1

6

Ø 300

Ø 200

Ø 260

24° 24°

33° 33°

n°8

fo

ri

Ø d

L

H

T

Ø MAX

Ø D

37

Page 38: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

39

12’’ XS12 Submersible

Dimensions and weights

XS12(2AX)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS12(2AX)/1B XSP302A/1B 1880 955 925 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 275

XXS12(2AX)/1A XSP302A/1A 1950 955 995 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 289

XXS12(2AX)/1 XSP302A/1 2090 955 1135 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 313

XXS12(2AX)/2B XSP302A/2B 2485 1150 1335 301 8’’ 192 8’’MS 201 NEMA 1.18.424 165 386

XXS12(2AX)/2A XSP302A/2A 2645 1150 1495 301 8’’ 192 8’’MS 201 NEMA 1.18.424 165 416

XXS12(2AX)/2 XSP302A/2 2720 1150 1570 301 8’’ 238 10’’MS 251 165 567

XXS12(2AX)/3B XSP302A/3B 2775 1345 1430 301 8’’ 238 10’’MS 251 200 555

XXS12(2AX)/4B XSP302A/4B 3200 1540 1660 301 8’’ 238 10’’MS 251 235 670

XXS12(2AX)/4A XSP302A/4A 3450 1540 1910 301 8’’ 238 10’’MS 251 235 757

XXS12(2AX)/4 XSP302A/4 3448 1540 1910 301 8’’ 288 12’’MS 300 235 932

XXS12(2AX)/5B XSP302A/5B 3645 1735 1910 301 8’’ 238 10’’MS 251 270 792

XXS12(2AX)/6B XSP302A/6B 3688 1930 1760 301 8’’ 288 12’’MS 300 305 935

XXS12(2AX)/7B XSP302A/7B 4033 2125 1910 301 8’’ 288 12’’MS 300 340 1037

XXS12(2AX)/8B XSP302A/8B 4378 2320 2060 301 8’’ 288 12’’MS 300 375 1140

XS12(2BX)

Model T H L Ø Max Ø D Ø d L + H Kg

T H (mm) (mm) (mm) (mm) “G (mm) L NEMA H T

XS12(2BX)/1C XSP302B/1C 1880 955 925 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 275

XS12(2BX)/1B XSP302B/1B 1950 955 995 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 289

XS12(2BX)/1A XSP302B/1A 2020 955 1065 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 302

XS12(2BX)/1 XSP302B/1 2190 955 1235 301 8’’ 192 8’’MS 201 NEMA 1.18.424 130 333

XS12(2BX)/2C XSP302B/2C 2485 1150 1335 301 8’’ 192 8’’MS 201 NEMA 1.18.424 165 386

XS12(2BX)/2B XSP302B/2B 2645 1150 1495 301 8’’ 192 8’’MS 201 NEMA 1.18.424 165 416

XS12(2BX)/2A XSP302B/2A 2580 1150 1430 301 8’’ 238 10’’MS 251 165 520

XS12(2BX)/3C XSP302B/3C 2775 1345 1430 301 8’’ 238 10’’MS 251 200 555

XS12(2BX)/2 XSP302B/2 2720 1150 1570 301 8’’ 238 10’’MS 251 165 567

XS12(2BX)/3B XSP302B/3B 2915 1345 1570 301 8’’ 238 10’’MS 251 200 602

XS12(2BX)/3A XSP302B/3A 3005 1345 1660 301 8’’ 238 10’’MS 251 200 635

XS12(2BX)/4B XSP302B/4B 3450 1540 1910 301 8’’ 238 10’’MS 251 235 757

XS12(2BX)/5C XSP302B/5C 3645 1735 1910 301 8’’ 238 10’’MS 251 270 792

XS12(2BX)/4A XSP302B/4A 3298 1540 1758 301 8’’ 288 12’’MS 300 235 865

XS12(2BX)/6C XSP302B/6C 3688 1930 1758 301 8’’ 288 12’’MS 300 305 935

XS12(2BX)/4 XSP302B/4 3488 1540 1908 301 8’’ 288 12’’MS 300 235 932

XS12(2BX)/5A XSP302B/5A 3643 1735 1908 301 8’’ 288 12’’MS 300 270 967

XS12(2BX)/7C XSP302B/7C 4033 2125 1908 301 8’’ 288 12’’MS 300 340 1037

XS12(2BX)/6A XSP302B/6A 3988 1930 2058 301 8’’ 288 12’’MS 300 305 1070

M 1

6

Ø 300

Ø 200

Ø 260

24° 24°

33° 33°

n°8

fo

ri

Ø d

L

H

T

Ø MAX

Ø D

38

Page 39: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

42

Applications

Domestic applications for 4’’

or larger water wells.

Motor

Water cooled encapsulated PSC motors.

Class B insulation.

IP 68 protection.

4’’ NEMA flange.

Rotation: CCW facing shaft end

on single phase the motor is

connected to only one capacitor

which works permanently as start

and run capacitor.

Benefits

Non contamination, water filled design.

Hermetically sealed stator.

Anti track, self healing stator resin

prevents motor burn out.

A4F Submersible

Franklin electric 4’’ motors (water cooled) and cable tails for ES4

Limitations

Maximum liquid temperature 30 °C.

Maximum quantity of sand in

suspension:

Starts: 20 per hour

Frost protection to – 15 °C.

Accesories

Cable tails to suit Franklin Motors

1.5m long.

2.5m long.

2.5m long c/w stainless steel connector.

Motor shrouds (Horizontal mounting)

4’’ Cooling shroud.

4’’ Support Feet.

4’’ Filter.

Hydraulic performance table

Model I [A]P2 Cable section in [mm2]

[kW] [HP] 4x1.5 4x2.5 4x4 4x6 4x10

254 805 1621L

23

0/2

40

V S

ing

le-p

ha

se

3.2 0.37 0.5 120 200 320 480 810

254 807 1621L 4.1 0.55 0.75 80 130 220 320 550

254 808 1621L 5.4 0.75 1 60 100 170 250 430

254 809 1621L 8.1 1.1 1.5 40 70 120 180 300

254 810 1621L 10.2 1.5 2 30 60 90 130 230

254 811 2521L 15.2 2.2 3 20 40 60 90 150

254 761 1621L

38

0/4

00

/415

V T

hre

e-p

ha

se

1.1 0.37 0.5 810 1350 2160 3240 5500

234 762 1621L 1.6 0.55 0.75 550 920 1480 2230 3780

234 763 1621L 2.1 0.75 1 410 680 1090 1640 2780

234 724 1621L 3 1.1 1.5 300 500 810 1210 2060

234 725 1621L 4 1.5 2 220 370 590 880 1500

234 726 2521L 5.9 2.2 3 150 250 400 600 1030

234 764 2521L 7.8 3 4 110 190 310 460 790

234 727 3421L 9.1 3.7 5 80 140 230 340 590

234 765 3421L 10 4 5.5 80 140 230 340 590

234 728 3421L 13.7 5.5 7.5 60 110 170 260 440

234 729 3421L 18.4 7.5 10 32 53 90 130 210

Dry run protectors for 4’’ Franklin H3F single & three phase motors

Model Description

CS 3WF-2 DRP (1.1KW) Single motor connector c/w 1.5mtrs of cable for PSC Franklin single phase H3F motors with DRP up to 1.1kw

CS 3WF-2.5 DRP (1.5KW) Single motor connector c/w 2.5mtrs of cable for PSC Franklin single phase H3F motors with DRP 1.5kw

CS 3WF-2 DRP (2.2KW) Single motor connector c/w 1.5mtrs of cable for PSC Franklin single phase H3F motors with DRP 2.2kw

CS 3W TO.37 DRP (0.37KW) Single motor connector c/w 2.0mtrs of cable for Franklin three phase HTF motors with DRP 0.37kw

CS 3W TO.55 DRP (0.55KW) Single motor connector c/w 2.0mtrs of cable for Franklin three phase HTF motors with DRP 0.55kw

CS 3W TO.75 DRP (0.75KW) Single motor connector c/w 2.0mtrs of cable for Franklin three phase HTF motors with DRP 0.75kw

CS 3W T110 DRP (1.1KW) Single motor connector c/w 2.0mtrs of cable for Franklin three phase HTF motors with DRP 1.1kw

CS 3W T150 DRP (1.5KW) Single motor connector c/w 3.0mtrs of cable for Franklin three phase HTF motors with DRP 1.5kw

CS 3W T220 DRP (2.2KW) Single motor connector c/w 3.0mtrs of cable for Franklin three phase HTF motors with DRP 2.2kw

CS 3W T300 DRP (3.0KW) Single motor connector c/w 3.0mtrs of cable for Franklin three phase HTF motors with DRP 3.0kw

CS 3W T400 DRP (4.0KW) Single motor connector c/w 3.0mtrs of cable for Franklin three phase HTF motors with DRP 4.0kw

39

Page 40: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

43

Applications

6” motors with resin-coated stator for

mounting with 6” submersible pumps

equipped with a NEMA coupling system.

Materials

Stainless steel inner and outer casing

AISI 304.

Shaft stainless steel AISI 420.

Graphite double radial bearings.

Axial bearing stainless steel AISI 304.

Stators hermetically sealed in resin.

Water lubricated axial and radial bea-

rings. Motors pre-filled with non-con-

taminating FES91/92 liquid and 100%

tested.

“Sandfighter” motor with silicon carbide

seal.

A6F Submersible

6” Franklin submersible motors

Motor

Asynchronous, two poles.

IP 68 Protection.

Class F insulation.

Continuous service.

Limitations

Maximum operating temperature: 30 °C

up to 30 kW, 50 °C for 37 and 45 kW.

Maximum number of starts per hour: 20.

Voltage tolerance: from +6% to - 10%.

Vertical mounting. Horizontal mounting

permitted only with 6” hydraulics

ensuring sufficient axial load.

Characteristics table

ModelP2 Cable section in [mm2]

[kW] [HP] 4x1.5 4x2.5 4x4 4x6 4x10 4x16 4x20

A6F 550 4 5.5 85 140 225 335

A6F 750 5.5 7.5 65 110 175 260

A6F 1000 7.5 10 45 80 125 190 320

A6F 1250 9.2 12.5 65 105 160 265

A6F 1500 11 15 55 85 130 220 355

A6F 2000 15 20 65 100 170 270

A6F 2500 18.5 25 85 140 225 350

A6F 3000 22 30 70 115 185 285

A6F 4000 30 40 85 135 215

A6F 5000 37 50 110 170

Motor characteristics table

Model I [A] IA [A]

P2Cos Thrust [N] %

Cable

[kW] [HP] Ø [mm2] Length [m]

A6F 550

40

0 V

Avv

Dir

ect

9.3 43 4 5.5 0.82 6500 78 4x4 4

A6F 750 12.5 64 5.5 7.5 0.82 6500 79 4x4 4

A6F 1000 16 83 7.5 10 0.86 15500 79 4x4 4

A6F 1250 20.7 112 9.2 12.5 0.80 15500 81 4x4 4

A6F 1500 23.3 129 11 15 0.85 15500 81 4x4 4

A6F 2000 31.3 169 15 20 0.85 15500 81 4x4 4

A6F 2500 38.5 231 18.5 25 0.85 15500 82 4x4 4

A6F 3000 45.3 268 22 30 0.86 15500 83 4x4 4

A6F 4000 63.5 393 30 40 0.84 27500 83 4x4 4

A6F 550

40

0 V

Avv

Y

9.3 43 4 5.5 0.82 6500 78 4x4 4

A6F 750 12.5 64 5.5 7.5 0.82 6500 79 4x4 4

A6F 1000 16 83 7.5 10 0.86 15500 79 4x4 4

A6F 1250 20.7 112 9.2 12.5 0.80 15500 81 4x4 4

A6F 1500 23.3 129 11 15 0.85 15500 81 4x4 4

A6F 2000 31.3 169 15 20 0.85 15500 81 4x4 4

A6F 2500 38.5 231 18.5 25 0.85 15500 82 4x4 4

A6F 3000 45.3 268 22 30 0.86 15500 83 4x4 4

A6F 4000 63.5 393 30 40 0.84 27500 83 4x4 4

Dimensions and weights

Model A B Kg

A6F 550 600 139 39.5

A6F 750 631 139 43.2

A6F 1000 660 139 45.5

A6F 1250 685 139 49

A6F 1500 730 139 53

A6F 2000 758 139 59

A6F 2500 860 139 66.5

A6F 3000 920 139 72.5

A6F 4000 1050 139 85

A

B

40

Page 41: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

44

Applications

Domestic applications for 8’’

or larger water wells.

Materials

Standard material in stainless steel 304

or stainless steel 316 on request.

Benefits

Non contamination, water filled design.

Hermetically sealed stator.

Anti track, self healing stator resin

prevents motor burn out.

Removable “Water Bloc” lead

connector.

Cable material according to drinking

water regulations.

Sand slinger and mechanical seal

for high performance in sand.

High efficiency electrical design

for low operation cost.

All motors prefilled and 100% tested.

A8F Submersible

Franklin electric 8’’ motors and cable tails for 8’’ submersible pumps

Motor

Water cooled encapsulated motors.

Class B insulation.

IP 68 protection.

8’’ NEMA flange.

Standard voltage: 415 V / 50 Hz,

460 V/60 Hz.

Voltage tolerance: +6%/-10%.

Limitations

Maximum liquid temperature 30 °C.

Vertical or horizontal installation.

Starts: 20 per hour.

Frost protection to – 15 °C.

Cooling flow: min 0.16 m/s.

Characteristics table (Direct On Line Start)

Characteristics table (Sur Delta Start)

Model I [A]P2

Cos Thrust [N] %Cable Dimensions and weights

[kW] [HP] Ø [mm2] Length [m] L [mm] [Kg]

A8F 4000 1.1 30 40 0.84 45000 86 3x8.4 8 925 145

A8F 5000 1.6 37 50 0.86 45000 87 3x8.4 8 1000 157

A8F 6000 2.1 45 60 0.85 45000 87 3x8.4 8 1077 172

A8F 7500 3 55 75 0.87 45000 88 3x16 8 1394 202

A8F 10000 4 75 100 0.87 45000 87 3x16 8 1496 240

A8F 12500 5.9 93 125 0.83 45000 87 3x16 8 1748 318

A8F 15000 7.8 110 150 0.84 45000 88 3x35 8 1976 381

A8F 17500 9.1 130 175 0.87 45000 88 3x35 8 2179 420

A8F 20000 10 150 200 0.88 45000 88 3x35 8 2408 494

Model I [A]P2

Cos Thrust [N] %Cable Dimensions and weights

[kW] [HP] Ø [mm2] Length [m] L [mm] [Kg]

A8F 4000

38

0/4

15 V

Th

ree

-ph

ase

1.1 30 40 0.84 45000 86 3x8.4 8 925 145

A8F 5000 1.6 37 50 0.86 45000 87 3x8.4 8 1000 157

A8F 6000 2.1 45 60 0.85 45000 87 3x8.4 8 1077 172

A8F 7500 3 55 75 0.87 45000 88 3x16 8 1394 202

A8F 10000 4 75 100 0.87 45000 87 3x16 8 1496 240

A8F 12500 5.9 93 125 0.83 45000 87 3x16 8 1748 318

A8F 15000 7.8 110 150 0.84 45000 88 3x16 8 1976 381

A8F 17500 9.1 130 175 0.87 45000 88 3x16 8 2179 420

A8F 20000 10 150 200 0.88 45000 88 3x16 8 2408 494 69

,85

L

Ø19

5.6

ma

x.

130

.30

130

.05

101.

60

101.

35

127

126.92

Ø127

Ø126.94

Ø152.4

BC

Ø17.47

(4 Holes)

M8x31.75-6G

Ground

Screw

38.10

38.07

42.93

Min Full

Spline

23.8

6.10

45°

41

Page 42: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

46

Single phase submersible motor control starter/protector

SubStart

Single phase submersible motor control

starter from 0.25 kW to 2.2 kW.

IP 54 protection.

Illuminated integral ON/OFF switch.

Thermal circuit breaker for protection

of the motor.

High quality motor run capacitor for

long life.

Temperature: -5 °C to +40 °C.

Humidity: 50% at 55 °C (without

condensation).

Franklin Accessories Submersible

SubStartSC® single phase submersible motor starter specifications

Model

Motor

rating

[kW]

Motor

rating

[kW]

Maximal

expected

current

[A]

Capacitor

[μF]

450 V ac

SS025SC 0.25 2.4 9.4 12.5

SS037SC 0.37 3.3 12.6 16

SS055SC 0,55 4.3 17.7 20

SS075SC 0.75 5.7 22.7 35

SS110SC 1.10 8.4 33.9 40

SS150SC 1.50 10.7 41.7 50

SS220SC 2.20 14.7 61.8 70

140168115

140

Ø5.2

193

165

7 22

87

90

SubTronic® single phase submersible motor protector models

Model

Motor

rating

[kW]

Motor

rating

[kW]

Maximal

expected

current

[A]

Capacitor

[μF]

450 V ac

ST025PSC 0.25 2.4 9.4 12.5

ST037PSC 0.37 3.3 12.6 16

ST055PSC 0,55 4.3 17.7 20

ST075PSC 0.75 5.7 22.7 35

ST110PSC 1.10 8.4 33.9 40

ST150PSC 1.50 10.7 41.7 50

ST220PSC 2.20 14.7 61.8 70

Ø5.2

90

230230 180

180

195

140

245

SubTronic

Single phase submersible motor control

protector from 0.25 kW to 2.2 kW.

IP 54 protection.

Dry-run protection (without probes).

Automatic dry-run reset time 6

to 60 minutes.

Over & under voltage protection,

reset 3 minutes approx.

Over current protection, reset

10 minutes approx.

Faulty start protection.

Rapid cycle protection.

Indicators for status, voltage & fault.

Temperature: -5 °C to +40 °C.

Humidity: 50% at 55 °C (without

condensation).

SubTronic three phase options (P.O.A)

42

Page 43: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

47

Franklin Accessories Submersible

Single phase constant pressure controller

SubDrive

Single phase constant pressure

controller from 1.1, 1.5 & 2.2 kW.

IP 23 protection (Indoor).

Works with a three phase, 60 Hz,

230 V Franklin motor.

Three phase perfomance with single

phase input:

High starting torque.

More efficient.

Smooth running.

Constant water pressure with a wide

range of settings 2-6 bar.

Soft start feature prevents water hammer

and increases motor life.

Works with small pressure tanks or

existing larger tanks.

Smart Reset technology allows well

recovery before restarting

the pump.

Excellent radio frequency interference

shielding.

Protections

Surge protection.

Under load.

Under voltage.

Locked pump.

Open circuit.

Short circuit.

Overheated controller.

Constant pressure controls specifications

SubDrive 75 SubDrive 100 SubDrive 150

Rated Power 1.1 kW 1.5 kW 2.2 kW

Inp

ut

(Fro

m

po

we

r so

urc

e) Voltage [V] 190 - 260 V / 1 Phase 190 - 260 V / 1 Phase 190 - 260 V / 1 Phase

Frequency [Hz] 60 / 50 Hz 60 / 50 Hz 60 / 50 Hz

Max. Amps [RMS] [A] 11 A 19 A 23 A

Power factor 1 (Constant) 1 (Constant) 1 (Constant)

Ou

tpu

t (T

o m

oto

r) Voltage [V] Variable / 3 Phase Variable / 3 Phase Variable / 3 Phase

Frequency [Hz] Variable (30 - 80 Hz) Variable (30 - 80 Hz) Variable (30 - 80 Hz)

Max. Amps [RMS] [A] 8.1 A 10.9 A 17.8 A

For

use

wit

h

Pump rating [kW] 0.55, 0.75 or 1.1 kW (Selectable) 0.75, 1.1 or 1.5 kW (Selectable) 1.1, 1.5 or 2.2 kW (Selectable)

Motor rating [kW] 1.1 kW, 230 VAC, 60 Hz (3 - Phase) 1.5 kW, 230 VAC, 60 Hz (3 - Phase) 2.2 kW, 230 VAC, 60 Hz (3 - Phase)

Pressure sensor (Included) External External External

Controller weight [Kg] 7 8 8

Carton size (H x W x D) [cm] 42 x 31 x 23 42 x 31 x 23 42 x 31 x 23

Shipping weight [Kg] 9 10 10

A

B

C

D

E

F

H

G

Dimensions in mm

Model A B C D E F G H

SubDrive 75 133 292 140 248 325 356 28 13

SubDrive 100 133 292 140 248 325 356 28 13

SubDrive 150 133 292 140 248 325 356 28 13

43

Page 44: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

48

Applications

Irrigation, decanting

and hydropneumatic sets.

Max. immersion level according

to technical table on page 281.

Materials

Outer casing, discharge body, impellers,

filter and motor casing in stainless steel

AISI 304.

Pump shaft in stainless steel AISI 303.

Diffusers in tecnopolimer.

Double mechanical seal in ceramic/

graphite/NBR.

Foodgrade oil in seal chamber.

Acuaria 07N/17/27 Submersible

Submersible multi-stage pumps for open wells

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Water-cooled motor.

Single-phase motor with built-in thermal

protection.

Acuaria 07N/17/27:

without floating level switch.

Acuaria 07N A/17 A/27 A:

with floating level switch.

Limitations

Maximum liquid temperature: 40 °C.

Equipment

Complete with 15 m of power cable for M

version or 10 m MA version.

Acuaria 07N M: for open wells with

a minimum Ø 125 mm.

Internal capacitor.

Acuaria 17/27 M: for open wells with

a minimum Ø 140 mm.

External capacitor (Box extra).

See page 262

Accessories.

Dimensions and weights

Acuaria 07N 3

Acuaria 07N 4

Acuaria 07N 5

Acuaria 07N 6

Acuaria 07N 7

Acuaria 17 5

Acuaria 17 7

Acuaria 27 4

Acuaria 27 6

470

493

517

560

583

553

646

552

655

10,0

10,6

11,5

12,4

12,6

14

14.2

17

17.2

1”

1”

1”

1”

1”

1”

1”

1”

1”

126

126

126

126

126

138

138

138

138

Model A [Kg]CB

A

B

C

Acuaria 07N

A

B

C

Acuaria 17/27

44

Page 45: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

49

Acuaria 07N/17/27 Submersible

Hydraulic performance table

7

10.8

2.5

3.8

1.5

2.2

1.4

2.1

0.9

1.5

1.25

2.0

16

25

I [A]

1~

230 V 400 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

43

68

42

66

1.2

20

41

64

1.8

30

39

61

2.4

40

38

57

3.0

50

31

47

3.6

60

23

36

4.8

80

14

24

7.26.0

120100

mw

cAcuaria 27 4

Acuaria 27 6

7.4

10.7

2.6

3.8

1.6

2.2

1.5

2.1

0.9

1.5

1.25

2.0

16

25

I [A]

1~

230 V 400 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

67

94

0.6

10

65

90

1.2

20

62

85

1.8

30

55

78

2.4

40

48

69

3.0

50

39

58

3.6

60

18

30

4.8

80

12

22

5.1

85

mw

cAcuaria 17 5

Acuaria 17 7

I [A]

1~

230 V 400 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

0.6

10

1.2

20

1.8

30

2.4

40

2.7

45

3.0

50

3.6

60

2.8

3.5

4.1

5.0

5.5

1.2

1.7

1.9

2.0

2.4

0.6

0.8

1

1.2

1.4

0.6

0.8

1

1.1

1.3

0.37

0.5

0.75

0.9

1.1

0.5

0.75

1

1.2

1.5

12

12

12

16

30

33

41

50

60

70

29

37

46

55

64

26

32

40

47

55

21

26

32

37

44

18

22

27

32

38

15

19

23

26

31

8

10

13

15

18

4

6

8

9

11

3.9

65

mw

c

Acuaria 07N 3

Acuaria 07N 4

Acuaria 07N 5

Acuaria 07N 6

Acuaria 07N 7

Performance curves at 2900 rpm

Acuaria 07N Acuaria 17

Acuaria 27

7

6

5

4

3

7

5

6

4

45

Page 46: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

50

Acuaria 37/57 Submersible

Submersible multi-stage pumps for open wells

Applications

Specially designed for irrigation

and hydropneumatic sets.

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Water-cooled motor.

Limitations

Maximum liquid temperature: 40 °C.

Max. immersion level according to the

technical table on page 281.

A

B

C

Acuaria 37 4

Acuaria 37 6

Acuaria 57 4

622.5

671.5

684

27.6

30.6

30.6

1 1/2”

1 1/2”

1 1/2”

152

152

152

Model A [Kg]CB

Performance curves at 2900 rpm

See page 262

Accessories.

Materials

Outer casing, motor casing, impellers

and filter in stainless steel AISI 304.

Motor shaft and pump shaft in stainless

steel AISI 303.

Diffusers in technopolymer.

Double mechanical seal in ceramic/

graphite/NBR.

Pump base and discharge body

in cast iron painted with cataforesis.

Foodgrade oil in seal chamber.

Energy Index MEI 0,4.

Equipment

Complete with 15 m of power cable.

Capacitor (single-phase only, box extra).

Acuaria 37/57: for open wells with a

minimum Ø 155 mm.

Dimensions and weights

37-6

37-457-4

Hydraulic performance table

Model

5.49.4 3 2.2 3

I [A]

1~

230 V 400 V230 V3~

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

48.1

6.0

100

52.5mwc

3.0

50

42.2

9.0

150

37.8

12

200

31.5

15

250

23.2

18

300

12.1

21

350

Acuaria 57 4

9.2 3.3

5.3

5.2

9.2

2 1.9

3

1.1

2.2

1.5

3

30

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

55.7

84.5

53.4

80.7

2.41.2

4012

50.9

77.4

3.6

60

46.5

72.3

4.8

80

41.0

64.8

6.0

100

35.2

56.3

7.2

120

29.1

46.1

8.4

140

22.3

37.2

160

mw

cAcuaria 37 4

Acuaria 37 6

9.6

46

Page 47: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

51

Idrogo Submersible

Submersible pumps used in our variable speed Sub-Tanks

Applications

For water boosting in our Sub-Tanks.

Clean water movement from wells, tanks

and for irrigation.

Motor

Asynchronous 2 pole motor cooled by

the pumped liquid.

Class F insulation.

IP 68 protection.

Permanent splits capacitor and automatic.

Thermal overload protection for single

phase version.

Thermal protection for three phase by

others.

Performance curves at 2900 rpm

Materials

External casing, motor casing, cover

& closing ring in AISI 304.

Impeller, diffuser & spacer in tecnopolmer.

Shaft in AISI 304.

Upper mechanical seal in carbon/

ceramic/NBR.

Lower mechanical seal in Sic/Carbon/NBR.

Limitations

Maximum liquid temperature 40 °C.

Maximum immersion depth 20 m.

Maximum working pressure 10 bar.

Horizontal or vertical installation.

Supplied with 5 mtrs of cable HØ7RN-F.

Dimensions

Hydraulic performance table

Model

P2 P1 [kW] I[A] Locked rotor current Single phase

[kW] [HP] Single phase Three phaseSingle

phase230 V 400 V

Single phase

230 V

Single phase

400 V[μF] 0.6

Idrogo 40/06 0.45 0.6 0.82 3.8 16 16 450

Idrogo 40/08 0.6 0.8 1 0.95 4.3 3.3 1.9 16 10 16 450

Idrogo 40/10 0.75 1 1.25 1.18 5.7 3.8 2.2 20 12 20 450

Idrogo 40/12 0.9 1.2 1.42 1.33 6.8 4.2 2.4 23 14 20 450

Idrogo 40/15 1.1 1.5 1.6 1.55 7.3 5.2 3 25 16.5 31.5 450

Idrogo 80/12 0.9 1.2 1.33 1.22 6.4 4 2.3 23 14 20 450

Idrogo 80/15 1.1 1.5 1.62 1.52 7.5 5.4 3.1 25 16.5 31.5 450

Idrogo 80/20 1.5 2 1.9 6.1 3.5 16.5

H

[ft]

250

200

150

100

50

0

70

60

50

40

30

20

10

0

H

[m]40/15

40/12

40/10

40/08

40/06

80/20

80/15

80/12

1101009080706050403020100

6543210

Q [l/min]

Q [m3/h]

lmp g.p.m.

U.S. g.p.m. 10 15 20 25 30

5 10 15 20 25

A

B

D

CModel A B C D

Idrogo 40/06 513 Ø 138 G 11/4’’ 30

Idrogo 40/08 513 Ø 138 G 11/4’’ 30

Idrogo 40/10 539 Ø 138 G 11/4’’ 30

Idrogo 40/12 590 Ø 138 G 11/4’’ 30

Idrogo 40/15 616 Ø 138 G 11/4’’ 30

Idrogo 80/12 540 Ø 138 G 11/4’’ 30

Idrogo 80/15 564 Ø 138 G 11/4’’ 30

Idrogo 80/20 590 Ø 138 G 11/4’’ 30

47

Page 48: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

52

MXO Drainage

Portable submersible pumps for drainage

Applications

Emptying of drains, residential sumps,

rain water tanks, etc.

Emergency emptying of flooded garages

or basements.

Water transfer from tanks and cisterns.

Materials

Outer casing: stainless steel AISI 304.

Impeller in tecnopolymer.

Diffuser, motor casing, pump base and

upper cover in stainless steel AISI 304.

Pump shaft in stainless steel AISI 303.

Double sealed. Mechanical seal on the

pump side in silicon carbide/alumine

oxided. Lip seal on motor side in NBR.

O-rings: NBR.

Motor

Asynchronous single-phase, two poles.

Built-in thermal protection and capacitor.

Cooling via circulation of pumped liquid.

Protection IP 68.

Isolation class F.

Limitations

Maximum immersion: 5 m.

Maximum liquid temperature: 40° C.

Maximum passage of solids: Ø10 mm.

Equipment

Supplied with 5 m of electric cable

H07RN-F and plug.

With float switch.

MXO M: without float switch.

MXO M A: with float switch.

Performance curves at 2900 rpmDimensions and weights

Model A B C D E F G Kg

MXO 30 1 1/4" 154 47 249 228 45 Ø132 5.5

MXO 60 1 1/4" 154 47 249 228 45 Ø132 6.2

B

A

F

C

DE

Q [l/1’]

H

[m]

0

2

4

4

6

6

8

8

10

10 Q [m3/h]

U.S. g.p.m.

Imp g.p.m.H

[ft]

0

5

10

15

20

25

30

35

10 20 30 40

10 20 30 40

50

0

0

50 100 150

2

30M A

60M A

Hydraulic performance table

Model

I

[A]

P1

[kW]P2 c l/min 0 25 50 75 100 125 150 175

1~

230 V

1~

230 V[kW] [HP] [μF] m3/h 0 1.5 3.0 4.5 6.0 7.5 9.0 10.5

MXO 30 2.2 0.5 0.25 0.33 8

mw

c 8.0 7.2 6.2 5.2 4.0 2.6 1.0

MXO 60 3.0 0.7 0.45 0.6 10 10.0 8.8 8.0 6.8 5.6 4.5 3.0 1.2

48

Page 49: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

53

Best Drainage

Submersible drainage pumps

Applications

For draining garages, irrigation

for gardens and emptying of wine cellars

and basements.

Materials

Pump body, impeller, motor casing

in stainless steel AISI 304.

Mechanical seal in ceramic/carbon/NBR.

Lip seal in NBR.

Motor

Cooling via circulation of pumped liquid.

IP 68 protection.

Class F insulation.

Continuous operation.

Built-in thermal protection.

Limitations

Maximum passage of solids: 10 mm.

Maximum immersion: 5 m.

Maximum liquid temperature: 50 °C.

Equipment

Supplied with 10 m of electrical cable.

Integral capacitor.

MA version c/w float switch.

MS version c/w magnetic switch.

Puddle sucker base option.

I [A]

1~

230 V

3~

400 V

Model

P2 Locked rotor

current

[kW]1~

230 V[HP]

3~

400 V

P1 [kW]

1~

230 V

3~

400 V

2.3

2.2

2.3

2.2

1.9

0.8

0.8

0.51

0.50

0.47

0.44

0.25

0.25

0.25

0.25

0.25

0.33

0.33

0.33

0.33

0.33

0.8

0.8

8

8

8

c

[μF] 0

0

1.2

20

2.4

40

4.8

80

7.2

120

9.6

160

9.0

9.0

6.5

6.5

8.3

8.3

6.0

6.0

7.8

7.8

5.6

5.6

6.3

6.3

4.8

4.8

4.5

4.5

3.5

3.5

2.4

2.4

2.0

2.0

1.8

1.8

1.5

1.5

10.2

170

m3/h

l/min

mw

c

Best One M

Best One

Best One Vox M

Best One Vox

Optima

Best One

Best One M

Best One MA / Optima MA

Best One MS / Optima MS

Best One Vox

Best One Vox M

Best One Vox MA

Model [Kg]

273

273

273

273

304

304

304

H

4.3

4.4

4.6

4.8

4.4

4.5

4.7

10

10

10

10

20

20

20

S

231

231

231

231

262

262

262

H1

Dimensions and weights

Hydraulic performance table

Performance curves at 2900 rpm

BEST ONE

OPTIMA

BEST ONE VOX

49

Page 50: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

54

Best 2-5 Drainage

Stainless steel submersible pumps

Applications

For draining wells, plant room sumps,

lift shaft emptying, pools, irrigation

and water displays.

Materials

Pump body, impeller, motor casing

in stainless steel AISI 304.

Double mechanical seal with

oil chamber, upper in carbon/ceramic/

NBR and lower in Sic/Sic/NBR.

Motor

Cooling via circulation of pumped liquid.

IP 68 protection.

Class F insulation.

Continuous operation.

Built-in thermal protection.

Limitations

Maximum liquid temperature 35 °C.

Maximum passage of solids 10 mm.

Maximum immersion 10 m.

Equipment

Maximum liquid temperature 40 °C.

Maximum immersion depth 20 m.

Maximum working pressure 10 bar.

Horizontal or vertical installation.

Supplied with 5 mtrs of cable HØ7RN-F.

Dimensions in mm

Hydraulic performance table

Performance curves at 2900 rpm

Model A B C D E F G

Best 2 352 315 210 10 G 11/2’’ 360 115

Best 3 352 315 210 10 G 11/2’’ 360 115

Best 4 377 340 210 10 G 11/2’’ 360 115

Best 5 377 340 210 10 G 11/2’’ 360 115

Model

I

[A]P2 c l/min 20 40 80 120 160 170 200 260 280 300 330 360

1~

230 V

3~

400 V[kW] [HP] [μF] m3/h 1.2 2.4 4.8 7.2 9.6 10.2 12 15.6 17 18 20 22

Best 2 4.4 2 0.55 0.75 16

mw

c

12.2 11 9.8 8.3 6.7 6.3 5 2.9

Best 3 5.6 2.4 0.74 1 20 13.6 13 11.1 9.5 7.9 7.6 6.4 4 3.2

Best 4 7.3 3 1.1 1.5 30 17.4 17 15 13 12 11.3 10 7.5 6.7 5.9 4.6

Best 5 3.3 1.5 2.2 18.4 18 16.1 15 13 12.5 11 9 8 7.4 6 5

54

32

H

[ft]

60

40

20

0

20

15

10

5

0

H

[m]

4003002001000

20100

Q [l/min]

Q [m3/h]

lmp g.p.m.

U.S. g.p.m. 50 100

50 100

50

Page 51: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

55

Hydraulic performance table

Model

I

[A]

P1

[kW]P2 c l/min 25 50 100 150 200 250 300 320

1~

230 V

1~

230 V[kW] [HP] [μF] m3/h 1.5 3.0 6.0 9.0 12 15 18 19.2

Drain 100 3.1 0.7 0.75 1 12 mwc 92 91 87 78 6 4 2 1

Drain 100 Drainage

Submersible pumps for the drainage of water without solids in suspension

Applications

Drainage of filtered water, emptying of

swimming pools, decorative fountains

and waterfalls.

Materials

Discharge body and upper mounting

in cast iron.

Impeller in tecnopolimer.

Double mechanical seal in ceramic/

graphite/NBR.

Filter in rigid plastic.

Motor housing and transport handle

in stainless steel AISI 304.

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Built-in thermal protection.

Drain 100 M: without float switch.

Drain 100 M A: with float switch.

Limitations

Maximum solids handling: 5 mm.

Maximum immersion: 8 m.

Maximum liquid temperature: 40 °C.

Equipment

Supplied with 10 m power cable.

Single-phase supplied with

capacitor box.

A

B

C

D

Performance curves at 2900 rpm

Drain 100

Model A

122

[Kg]

10.5

D

1 1/4”

C

300

B

392

Dimensions and weights

51

Page 52: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

56

DMR Drainage

Submersible pumps for clear water

Applications

Drainage of water without solids in

suspension.

Drainage of seepage water or rainwater,

via tanks and vats.

Materials

External housing, suction filter, cover

and impeller made of AISI 304 stainless

steel.

Diffusor in cast iron (G20)

Mechanical seal in silicon carbide-

alumina and alumina-carbon

NBR O-ring seals.

Motor shaft pump side in stainless steel

AISI 316.

Limitations

Through section: 8 mm.

Maximum immersion: 9 m.

Maximum liquid temperature: 40 °C.

with pump totally immersed.

Motor

Asynchronous two poles with oil bath

lubrication.

Class F insulation.

IP 68 protection.

Features

10 m long power cable.

Single-phase versions with built-in

capacitor and thermal protection.

Dimensions and weights

Model A B C D Kg

DMR 100 1 1/2" 190 213.5 300 13.5

DMR 140 1 1/2" 190 213.5 344 18.2

Hydraulic performance table

Model

I

[A] P1

[kW]

P2 l/min 0 25 50 100 150 200 250 300 400

1~

230 V

3~

400 V[kW] [HP] m3/h 0 1.5 3 6 9 12 15 18 24

DMR 100 6.5 2.6 1.3 0.75 1

mw

c 15 14 12.8 11.2 9.2 7.4 5.2 2.6

DMR 140 9 3 2 1.1 1.5 19.5 19 18.5 17.5 16 14 11.8 9.2 4

Performance curves at 2900 rpm

140

Q [l/1’]40030020010000

2

4

6

8

10

12

14

16

18

20

22

24

H[m]

100

52

Page 53: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

57

Viginox Drainage

Portable submersible pumps for drainage

Applications

Drainage of filtered water.

Emptying of pools and operation in

decorative fountains, waterfalls and

emptying of rainwater.

Materials

Outer casing, impeller, diffuser, motor

casing, pump base and upper cover in

stainless steel AISI 304.

Pump shaft in stainless steel AISI 316.

Double mechanical seal on the

pump side in silicon carbide/alumine

oxided.

Lip seal on motor side in NBR.

O-rings: NBR.

Limitations

Maximum immersion: 5 m.

Maximum liquid temperature: 50° C.

Maximum passage of solids: Ø10 mm.

Motor

Asynchronous, two poles.

Cooling via circulation of pumped liquid.

Oil-filled motor.

Protection IP 68.

Isolation class F.

Single-phase with built-in thermal

protection and capacitor.

The thermal protection for the three-pha-

se motors is to be provided by the user.

Equipment

Supplied with 10 m of electric cable

H07RN-F.

Viginox M: without float switch.

Viginox M A: with float switch.

Viginox T: three phase without float

switch.

Hydraulic performance table

Model

I

[A]

P1

[kW]P2 c l/min 0 100 200 300 350 400

1~

230 V

3~

400 V

1~

230 V

3~

400 V[kW] [HP] [μF] m3/h 0 6.0 12.0 18.0 21.0 24.0

Viginox 60 4.5 2.1 1.1 0.9 0.6 0.8 16

mw

c

11.5 8.0 4.5 2.5

Viginox 75 6.5 2.2 1.5 1.3 0.75 1.0 20 14.5 11.0 7.0 4.0 1.5

Viginox 110 10.6 3.3 2.2 2.0 1.1 1.5 30 16.5 14.0 11.0 9.0 7.0 2.0

Performance curves at 2900 rpm

Q [m3/h]

H[m]

0

2

4

6

8

10

12

14

16

Q [l/1’]0

U.S. g.p.m.

Imp g.p.m. H[ft]

0

10

20

30

40

50

60M75M

110M

20 40 60

100 200 300 400

15 20 25

80 100 120

20 40 60 80 100

0 105

Dimensions and weights

Model A B C D E F G Kg

Viginox 60 1 1/2" 212.4 89.7 290.2 259.2 50.5 Ø202.4 9.0

Viginox 75 1 1/2" 212.4 89.7 290.2 259.2 50.5 Ø202.4 11.0

Viginox 110 2” 212.4 89.7 326.7 294.7 50.5 Ø202.4 18.0

53

Page 54: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

58

Viginox V Drainage

Portable submersible pumps for drainage, Vortex system

Applications

Drainage of sewage/dirty water,

operation in septic tanks, small

purifying installations and emptying

of rainwater.

Specially adapted for building use.

Materials

Outer casing, impeller, diffuser, motor

casing, pump base and upper cover in

stainless steel AISI 304.

Pump shaft in stainless steel AISI 316.

Double mechanical seal on the

pump side in silicon carbide/alumine

oxided.

Lip seal on motor side in NBR.

O-rings: NBR.

Limitations

Maximum immersion: 5 m.

Maximum liquid temperature: 50° C.

Maximum passage of solids: Ø30 mm.

Motor

Asynchronous, two poles.

Cooling via circulation of pumped liquid.

Oil-filled motor.

Protection IP 68.

Isolation class F.

Single-phase with built-in thermal

protection and capacitor.

Equipment

Supplied with 10 m of electric cable

H07RN-F.

Viginox V M: without float switch.

Viginox V M A: with float switch.

Viginox V T: three phase without float

switch.

Performance curves at 2900 rpmDimensions and weights

Q [m3 /h]20 25

H[m]

0

2

4

6

8

10

12

14

Q [l/1’]0 100 200 300 400

H[ft]

0

10

20

30

40

50

Imp g.p.m. 100

U.S. g.p.m. 20

20

40 60 80

40 60 80

100 120

10 150 5

75M 110M

Hydraulic performance table

Model

I

[A]

P1

[kW]P2 c l/min 0 100 200 300 350 400

1~

230 V

3~

400 V

1~

230 V

3~

400 V[kW] [HP] [μF] m3/h 0.0 6.0 12.0 18.0 21.0 24.0

Viginox V 75 6.8 2.4 1.5 1.5 0.75 1.0 20

mw

c 10.5 8.5 6.5 3.5 2.0

Viginox V 110 9.0 3.3 2.2 2.0 1.1 1.5 30 12.5 10.5 8.0 6.0 4.0 2.0

Model A B C D E F G Kg

Viginox V 75 1 1/2" 204 73 344.2 325.2 106 Ø202 13.0

Viginox V 110 2" 204 73 384.7 393.2 106 Ø203 20.0

54

Page 55: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

59

Drainex 100 Drainage

Submersible pumps, Vortex system for sewage water

Applications

Drainage of sewage and dirty water,

operation in septic tanks and small

purifying intallations.

Materials

Discharge body and upper mounting

in cast iron.

Impeller in brass with free passage

of particles in suspension of Ø 34 mm.

Double mechanical seal in ceramic/

graphite and ceramic/silicon carbide.

Motor housing and transport handle in

stainless steel AISI 304.

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Single-phase version built-in thermal

protection.

Limitations

Maximum solids handling: 32 mm.

Maximum immersion: 8 m.

Maximum liquid temperature: 40 °C.

Equipment

Supplied with 10 m power cable.

Single-phase supplied with capacitor box.

Drainex 100M: without float switch.

Drainex 100M A: with float switch.

3.4 0.75 0.75 1 12

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

7mwc

1.5

25

6.7

3.0

50

5.9

6.0

100

5.5

7.5

125

5

9.0

150

3.7

12

200

2

15

250

1

16.8

280

Drainex 100M

Hydraulic performance table

Performance curves at 2900 rpm

Drainex 100

Model A

138

[Kg]

11

D

1 1/4”

C

300

B

407

A

B

C

D

Dimensions and weights

55

Page 56: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

60

TGR Drainage

Submersible pumps for drainage and sewage

Applications

Emptying of septic tanks, cesspools,

sewage collection wells, pumping of

sewage water with solids in suspension

by means of vortex impeller.

Materials

Outer casing, suction filter, support,

counter flange, cover, handle and

impeller in AISI 304 stainless steel.

Motor flange mount and pump body in

cast iron (G20).

Mechanical seal on pump side in silicon

carbide and alumina and NBR ring on

motor side.

O-ring: NBR.

Motor shaft pump side in stainless steel

AISI 316.

Motor

Asynchronous two poles with oil bath

lubrication.

Oil-filled motor.

IP 68 protection.

Class F isolation.

Limitations

Maximum immersion: 5 m.

Maximum liquid temperature: 50 °C.

Maximum passage of solids: Ø30 mm.

Features

10 m long power cable.

TGR M: without float switch.

TGR M A: c/w float switch.

TGR T: three phase without float switch.

Performance curves at 2900 rpm

Q [l/1’]800 9007006005004003002001000

100

150 200

300 F

0

1

2

3

4

5

6

7

8

9

10

11

12

13

H[m]

Hydraulic performance table

Model

I

[A] P1

[kW]

P2 l/min 0 100 200 300 400 500 700 950

1~

230 V

3~

400 V[kW] [HP] m3/h 0 6 12 18 24 30 42 57

TGR 100 7 3.2 1.3 0.75 1

mw

c

8.5 6.8 5 3.2 1

TGR 150 11.5 4.5 1.7 1.1 1.5 11 9 7.3 5.6 3.2

TGR 200 4.8 2.2 1.5 2 13 11.2 9.5 7.5 3.2

TGR 300 F 6.5 3.5 2.25 3 12.5 11.5 11 10.5 9.6 8.5 6.5 3

Dimensions and weights

Model A B C D E F G [Kg]

TGR 100 2’’ 150 232 396 125 50 150 13

TGR 150 2’’ 150 232 396 125 180 150 15

TGR 200 2’’ 150 232 396 125 180 150 15

TGR 300 F 3’’ 214 290 523 133 170 253 32

56

Page 57: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

61

Drainex 200/300 Drainage

Submersible monobloc pumps, Vortex system for sewage water

A

B

C

D

E F

G

H

I

E

FG

H I

A

B

C

D

J

Applications

Drainage of sewage and dirty water,

operation in septic tanks and small

purifying installations.

Materials

Pump body, discharge body, suction

body and impeller in cast iron.

Mechanical seal in silicon carbide

and ceramic.

Pump base in stainless steel AISI 304,

detachable for coupling of accessories.

O-rings in NBR.

Motor shaft in stainless steel AISI 420.

Motor

Asynchronous, two poles, high torque.

IP 68 protection.

Class F insulation.

Continuous operation.

Water-cooled motor.

Single-phase version built-in thermal

protection and capacitor.

Limitations

Maximum solids handling:

Drainex 200: 45 mm.

Drainex 300: 60 mm.

Maximum liquid temperature: 40 °C.

Equipment

Supplied with 10 m power cable.

Drainex M: without float switch.

Drainex M A: with float switch.

Drainex T: three phase without float

switch.

Transportable versions include elbow

and s/s feet.

Drainex 200

Drainex 201

Drainex 202

Model [Kg]

415

415

415

A

12

12

12

25

25

25

I

95

95

95

H

196

196

196

G

110

110

110

F

2”

2”

2”

E

118.7

118.7

118.7

D

383

383

383

C

239.5

239.5

239.5

B

Drainex 200/201/202

Impeller ext. Ø: Drainex 200: 105 mm. Drainex 201: 115 mm. Drainex 202: 124 mm.

Drainex 300

Drainex 301

Drainex 302

Model

429

429

429

A [Kg]

28

28

28

144

144

144

I

2 1/2”

2 1/2”

2 1/2”

J

110

110

110

H

150

150

150

G

110

110

110

F

222

222

222

E

118.7

118.7

118.7

D

408

408

408

C

271.5

271.5

271.5

B

Drainex 300/301/302

Impeller ext. Ø: Drainex 300: 105 mm. Drainex 301: 115 mm. Drainex 302: 124 mm.

Dimensions and weights

57

Page 58: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

62

Drainex 200/300 Drainage

5.5

6.8

7.8

2.4

2.7

3

1.2

1.5

1.8

1.2

1.5

1.8

1.1

1.1

1.1

1.5

1.5

1.5

16

16

16

I [A]

1~

230 V 400 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

7.1

9.2

11

3.0

50

6.6

8.5

10.5

6.0

100

5.4

7

9

12

200

4.1

5.6

7.4

18

300

2.9

4.1

5.8

24

400

1.8

2.8

4.2

30

500

1.5

2.6

36

600

1.8

39

650

mw

c

Drainex 300

Drainex 301

Drainex 302

5.2

6.2

7.4

2.3

2.6

2.8

1.1

1.4

1.6

1.1

1.4

1.6

1.1

1.1

1.1

1.5

1.5

1.5

16

16

16

I [A]

1~

230 V 400 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

10.7

13.2

15.1

3.0

50

9.7

11.9

13.8

6.0

100

8.6

10.7

12.6

9.0

150

7.4

9.4

11.3

12

200

4.9

6.7

8.5

18

300

2.3

3.8

5.6

24

400

2.4

4.1

27

450

2.5

30

500

mw

c

Drainex 200

Drainex 201

Drainex 202

Interior condenser is in

a completely watertight

chamber to simplify the

pump installation process.

Optimal cooling of the motor thanks to the motor

body being designed as a single part.

The incorporation of a mechanical seal guarantees

complete watertightness between the hydraulic part

and the motor. Large chamber between the impeller

and the aspiration cone which allows

suspended solid particles to pass

through. Drainex 200, 45 mm.

and Drainex 300, 60 mm.

Hydraulic performance table

Drainex 200

Performance curves at 2900 rpm

200 201 202

Drainex 300

300 301 302

58

Page 59: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

63

Portable version

437

A

98

I

55

M

55

L

110

K

134

J

98

H

49

G

95

F

62

E

219

D

110

C

338

B

Drainex 200/201/202

455

A

111

I

144

M

110

L

110

K

150

J

111

H

62

G

101

F

105

E

213

D

108

C

373

B

Drainex 300/301/302

H I

J

K

L

M

F

G

A

B

C D

E

G 2”

F

G

A

B

C D

E

G 21/2”

H I

J

K

LM

M16

Passage Ø of particles in suspension: 45mm

Drainex 200/300: without float switch. Drainex 200 A/300 A: supplied built-in float switch

405

A

15

I

85

M

Ø12

L

70

K

38

J

74.5

H

11.5

G

132

F

92

E

245.5

D

108

C

441

B

12

N

11

V

95

Z

50

Y

20.5

X

50.5

W

56

U

104

T

111

S

111

R

Ø10

Q

85

P

Ø42

O

Drainex 300/301/302

Fixed version, guide rail system

388

A

8

I

24

M

Ø10

L

50.5

K

12

J

52

H

60

G

112

F

60

E

168

D

110

C

353

B

209

N

12

V

60

Z

32

Y

13

X

40

W

94

U

120

T

98

S

98

R

Ø10

Q

85

P

Ø25

O

Drainex 200/201/202

R S

T

U

Z

V

W

X

Y

F

G

HI

J

PQ

A

B

C D E

K

L

M

N

O

G 2”

R S

T

U

Z

V

W

X

Y

FGH

IJ

P

Q

A

B

C D E

K

L

M

N

O

G 21/2”

Passage Ø of particles in suspension: 60mm

Drainex 200/300: without float switch. Drainex 200 A/300 A: supplied built-in float switch

Drainex 200/300 Drainage

59

Page 60: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

64

Drainex 400/500/600 Drainage

Submersible mono block pumps with Vortex impeller for draining water with solids

Applications

In water treatment facilities.

Pressurised drainage systems.

Drainage of faecal water from housing

and garages.

Drainage for water with solids in public

establishments, restaurants, etc.

General drainage systems in industry,

farms, livestock farms, excavations,

garages and civil engineering works.

Drainage of cesspits and septic tanks.

Atex version for installing in the facilities

described in the Atex regulations

(II 2G d II B T4).

Materials

Pump body and impeller in cast iron.

Double mechanical seal: on the pump

side in silicon carbide and on the motor

side in graphite/alumina oxide with an

intermediate oil chamber. The motor

shaft is not in contact with water.

AISI 304 stainless steel screws.

O-rings in NBR.

Electrical and motor specifications

Asynchronous, two pole.

IP 68 protection.

Class F insulation.

Continuous operation (fully submerged).

Atex II 2G version. Ex d II B t4.

Atex version is supplied with a humidity

sensor and thermal protection in case

the motor overheats.

To ensure full protection we recommend

installation of appropriate protection

and control panels (see accessories

section).

Limitations

Maximum immersion depth 9 m.

Maximum number of starts: 15 per hour.

Level switch. Optional for connecting

to electrical panel.

The whole Drainex range can operate

at a maximum temperature of 40 °C.

Water with solids or filtered water,

rainwater, wastewater and non-corrosive

liquids in general.

Solids passage Ø

Drainex 400/500: the passage of solids

of up to 40 mm with a DN 50 impeller.

Drainex 600: the passage of solids

of up to 65 mm with a DN 65 impeller.

Drainex 400

Drainex 401

Drainex 402

Model

488

488

488

A

313

313

313

B

130

130

130

C

Ø50

Ø50

Ø50

D

251

251

251

E

134

134

134

F

110

110

110

G

86

86

86

H

75

75

75

I

19

19

19

J

Ø14

Ø14

Ø14

K

86

86

86

L

142

142

142

M

45

45

45

[Kg]

Drainex 400/401/402

Impeller ext. Ø: Drainex 400: 115mm. Drainex 401: 125mm. Drainex 402: 136mm.

Drainex 500

Drainex 501

Drainex 502

Model

526

526

526

A

317

317

317

B

139

139

139

C

Ø50

Ø50

Ø50

D

256

256

256

E

134

134

134

F

110

110

110

G

85

85

85

H

80

80

80

I

18

18

18

J

Ø14

Ø14

Ø14

K

88

88

88

L

140

140

140

M

55

55

55

[Kg]

Drainex 500/501/502

Impeller ext. Ø: Drainex 500: 140mm. Drainex 501: 150mm. Drainex 502: 160mm.

Drainex 600

Drainex 601

Drainex 602

Model

567

567

567

A

348

348

348

B

139

139

139

C

Ø65

Ø65

Ø65

D

254

254

254

E

154

154

154

F

110

110

110

G

87

87

87

H

18

18

18

I

110

110

110

J

170

170

170

K

60

60

60

[Kg]

Drainex 600/601/602

Impeller ext. Ø: Drainex 600: 125mm. Drainex 601: 135mm. Drainex 602: 145mm.

A

B

C

D

FGH

I

J

E

KLM

A

B

C

D

FGH

I

J

E

KLM

A

B

C

D

FG

H

I

J

E

K

Dimensions and weights

60

Page 61: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

65

Performance curves at 2900 rpm

Drainex 400 Drainex 500

3

3.9

4.8

I [A]

5.7

6.8

8.1

Model

P2

3.7

3.7

3.7

[kW]

5

5

5

[HP]

P1 [kW]

3~

400 V

3~

400 Vm3/h

l/min

3.4

6

9

60

1000

14.8

18

21

12

200

4.3

78

1300

13.3

16.3

19

24

400

3.1

5.8

72

1200

10.4

14

16.8

36

600

6.3

9.8

13.3

48

800

mw

c

Drainex 600

Drainex 601

Drainex 602

4.2

5

5.3

I [A]

7.2

8.3

8.7

Model

P2

3.7

3.7

3.7

[kW]

5

5

5

[HP]

P1 [kW]

3~

400 V

3~

400 Vm3/h

l/min

13

16.8

20

36

600

23.2

27.4

30.1

6.0

100

6

49

810

19.7

23.5

26.8

18

300

8.5

12

45

750

17.6

21.2

24.5

24

400

15.6

19.1

22.2

30

500

mw

c

Drainex 500

Drainex 501

Drainex 502

1.9

2.45

3.1

I [A]

4.1

4.8

5.6

Model

P2

2.6

2.6

2.6

[kW]

3.5

3.5

3.5

[HP]

P1 [kW]

3~

400 V

3~

400 Vm3/h

l/min

2.8

5.2

9.3

36

600

14.6

17.3

20.7

6.0

100

2

48

800

12.7

15.5

18.6

12

200

3

5

42

700

8.3

11.6

13.7

24

400

5.9

9.3

12

30

500

mw

c

Drainex 400

Drainex 401

Drainex 402

Hydraulic performance table

Drainex 600

Drainex 400/500/600 Drainage

400 401 402

500

501

502

601600

602

61

Page 62: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

66

Portable version

537

A

251

I

110

K

134

J

110

H

70

G

64

F

124

E

130

D

238

C

408

B

575

A

256

I

110

K

134

J

110

H

70

G

64

F

129

E

139

D

234

C

412

B

Drainex 400/401/402 Drainex 500/501/502

616

A

110

I

110

L

150

K

254

J

144

H

83

G

105

F

136

E

139

D

272

C

458

B

Drainex 600/601/602

Drainex 400/500/600 Drainage

H

IJK

F

G

A

BCD

E

G 2”

H

I

JK

F

G

A

B

CD

E

G 2”

H I

JKL

F

G

A

BCD

E

G 21/2”

Detachable connector with hermetic seal.

Wide aperture for solids passage:

40 mm for the 400/500 series

65 mm for the 600 series

Double mechanical seal

to guarantee that the motor is

completely watertight.

Oil chamber for optimal lubrication

of the mechanical seal.

Oversized bearings to support the radial

and axial stress of the hydraulic set.

62

Page 63: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

67

Drainex 400/500/600 Drainage

Drainex 500/501/502

630

A

97

I

254

M

Ø65

L

1”

K

134

J

165

H

231

G

260

F

62

E

285

D

319

C

419

B

125

N

102

Ñ

Ø133

V

Ø21

Z

Ø120

Y

Ø140

X

Ø18

W

Ø60

U

127

T

254

S

12

R

13

Q

40

P

88

O

Drainex 600/601/602

Fixed version, guide rail system

I

532

A

65 Ø50

L

1”

K

105

J

125

H

182.5

G

214

F

62

E

258

D

130

C

363

B

116

N

93

Ñ

251

M

120.5

V

561

X

19

W

100

U

125

T

251

S

12

R

13

Q

40

P

88

O

I

566

A

61 Ø50

L

1”

K

105

J

125

H

182.5

G

215

F

62

E

255

D

139

C

360

B

116

N

93

Ñ

256

M

120

V

566.5

X

19

W

100

U

131

T

256

S

12

R

13

Q

40

P

88

O

Drainex 400/401/402

S

T

U

V

W

F

G

H

I

J

A

B

C D E

X

K

L

PQ

R

Ñ

M

N

O

S

T

U

V

W

F

G

H

I

J

A

B

C D E

X

K

L

PQ

R

Ñ

M

N

O

P

Q

R

M

N

O

Ñ

F

G

H

I

J

A

B

C D E

K

L

Z

X

Y

Flange DN65

S

T

U

V

W

Flange DN80

63

Page 64: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

68

Accessories

Drainex 200/300/400/500/600

Transportable version for Drainex 400/500 models

DR6 Kit

Stationary version for Drainex 400/500 models

DR3 Kit

Support base with elbow

for automatic anchoring.

DN 50 (flange 50)

Upper anchoring on

double guide tube.

ANSI 150 2”

90 ° elbow at 2”. Stainless steel feet.

Stationary version for Drainex 300 models

DR2 Kit

Stationary version for Drainex 200 models

DR1 Kit

Support base for

automatic anchoring.

Upper anchoring

on guide.

Clamping flange. Support base for

automatic anchoring.

Upper anchoring

on guide tube.

Clamping flange.

Transportable version for Drainex 600 modelsStationary version for Drainex 600 models

DR4 Kit

DR5 Kit

Support base with elbow

for automatic anchoring.

DN 65 (flange 80)

Clamping flange.

DIN 2501 PN16

Upper anchoring on

double guide tube.

ANSI 150 21/2”

DR7 Kit

Support base with elbow

for automatic anchoring.

Upper anchoring on

double guide tube.

Clamping flange.

DN 65 (flange 65) DIN 2501 PN16 ANSI 150 21/2”

90 ° elbow at 21/2”. Stainless steel feet.

64

Page 65: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

69

AL Series Drainage

Wastewater/Effluent submersible pumps

Applications

Waster water drainage for all industries.

Surface water, drainage & flood water.

Extraction of water from a river/lake.

Features

Equipped with auto-cut silicon carbide

double mechanical seal.

Entire cast iron construction

& compact design.

Available with guide rail system.

High head and efficiency for wide

range design.

Specifications Performance curves at 2900 rpm

Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class B (5 HP : Class F)

Protection IP 68

Protector Auto - cut

Bearing Ball type

M. seal Double m.seals

Impeller Semi - open

Material

Upper cover FC - 200

Motor frame FC - 200

Main shaft SUS 403

M. seal

Casing FC - 200

Impeller FC - 200

Cable VCT or H07RN-F or SJOW/SOW

Optional Float switch (5HP : none)

50 AL 21.550 AL 22.2 80 AL 21.5

80 AL 22.280 AL 23.7

0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60

0 0.2 0.4 0.6 0.8 1

Q [m3/h]

Q [l/1’]

U.S. g.p.m

Imp g.p.m

80 120 160 200 240 280

80 120 160 200 240

H

[m]

0

10

20

H

[ft]

80

60

40

20

0

Hydraulic performance table

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

50AL21.5 2 1.5 2’’ 50 12.5 0.4 12.5 24 19.5 0.7 19.5 42 20 3/4’’ 36 79 32 71

50AL22.2 3 2.2 2’’ 50 18 0.4 18 24 24.5 0.8 24.5 48 20 3/4’’ 38 84 35 77

80AL21.5 2 1.5 3’’ 80 8 0.6 8 36 15 1.1 15 66 20 3/4’’ 42 93 37 82

80AL22.2 3 2.2 3’’ 80 12 0.6 12 36 19 1.2 19 72 20 3/4’’ 44 97 40 88

80AL23.7 5 3.7 3’’ 80 23 0.5 23 30 30.5 1.2 30.5 72 14 1/2’’ 58 128

ModelP2 Discharge Phase 1 Ø 1 Ø 1 Ø 3 Ø 3 Ø 3 Ø 3 Ø m3/h 6 12 18 24 36 48 60 66

[HP] [kW] [inch] [mm] Voltage 220 V 230 V 240 V 230 V 380 V 400 V 415 V m3/min 0.1 0.2 0.3 0.4 0.6 0.8 1 1.1

50AL21.5 2 1.5 2’’ 50

Full

loa

d a

mp

ere

10.4 10 9.8 6.1 3.6 3.5 3.4

mw

c

18.5 17.1 15.1 12.5 4.8

50AL22.2 3 2.2 2’’ 50 15 14.6 14.4 8.6 5.1 5 4.8 24 22.7 20.7 18 10.5

80AL21.5 2 1.5 3’’ 80 10.4 10 9.8 6.1 3.6 3.5 3.4 14.2 13.2 12 10.8 8 4.9 1.8

80AL22.2 3 2.2 3’’ 80 15 14.6 14.4 8.6 5.1 5 4.8 18.3 17.4 16.4 15.2 12 8.2 4.1 2

80AL23.7 5 3.7 3’’ 80 14 8.4 8.2 7.7 29.6 29.2 26.6 24.9 20.6 15.2 8.4 4.4

65

Page 66: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

70

S Series Drainage

Stainless steel submersible pumps

Applications

Water drainage for industries, sanitary

sewer, single and multiple dwellings,

water drainage for chemical,

pharmaceutical and metal processing

factories. The series are suitable for

all light acid, corrosive and sea water

applications.

Features

Best estructure design, dry motor,

double mechanical seals, equipped with

auto-cut protector, cast stainless steel

body and cover, acid resisting silicon

carbide seals. Viton o rings are used

throughout the pump to give better

pump life in corrosive acid and

aggressive media.

Specifications Performance curves at 2900 rpm

Hydraulic performance table

Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications Corrosive / Food Procesing liquidis

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class B

Protection IP 68

Protector Auto - cut (SS-05A 1 Ø : Overheat)

Bearing Ball type

M. seal Double M.seals

Impeller Vortex

Material

Upper cover SCS 14

Motor frame SUS 316

Main shaft SUS 316

M. seal

Casing SCS 14

Impeller SCS 14

Cable VCT or H07RN-F or SJOW/SOW

Optional Float switch SCS 13 (SS05A : Upper cover & casing)

40

30

20

10

0

H

[m]

12

9

6

3

0

1816.51513.51210.597.564.531.50 Q [m3/h]

Q [m3/min]0.250.20.150.10.050

H

[ft]

U.S. g.p.m

Imp g.p.m 20

20 30 40 50 60 70 80

30 40 50 60 70

SS-21A

SS-05A

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

SS-05A 1/2 0.4 2’’ 50 7 0.12 7 7.2 10 0.26 10 15.6 10 1/2’’ 15 33 14 31

SS-21A 1 0.75 2’’ 50 10 0.17 10 10.2 14.5 0.35 14.5 21 10 1/2’’ 17 38 16 35

ModelP2 Discharge Phase 1 Ø 1 Ø 1 Ø 3 Ø 3 Ø 3 Ø 3 Ø m3/h 1.5 3 6 9 12 15 18

[HP] [kW] [inch] [mm] Voltage 220 V 230 V 240 V 230 V 380 V 400 V 415 V m3/min 0.025 0.05 0.1 0.15 0.2 0.25 0.3

SS-05A 1/2 0.4 2’’ 50

Full

loa

d

am

pe

re 3.4 3.3 3.2 2.3 1.4 1.3 1.3

mw

c 9.5 9 7.6 5.8 3.4 0.6

SS-21A 1 0.75 2’’ 50 5,4 5.2 5 3.3 2 1.9 1.8 14.1 13.6 12.3 10.7 8.7 6.3 3.4

66

Page 67: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

71

S Series Drainage

Stainless steel submersible pumps

Specifications Performance curves at 2900 rpm

Hydraulic performance table

Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications Corrosive / Food Procesing liquidis

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class B (5HP: Class F)

Protection IP 68

Protector Auto - cut (SS-05A 1 Ø : Overheat)

Bearing Ball type

M. seal Double M.seals

Impeller Vortex

Material

Upper cover SCS 14

Motor frame SUS 316

Main shaft SUS 316

M. seal

Casing SCS 14

Impeller SCS 14

Cable VCT or H07RN-F or SJOW/SOW

OptionalFloat switch (2HP & 3HP & 5HP : none)

SCS 13 (SS05A : Upper cover & casing)

60

0

10

20

30

40

50

H

[ft]

U.S. g.p.m 80 120 160 200 240 280

Imp g.p.m 40 80 120 160 200 240

H

[m]

16

0

4

8

12

540 6 12 18 24 30 36 42 48 Q [m3/h]

Q [m3/min]0.80.60.40.20

SF-05AU SF-21AU SF-32U

SF-33U

SF-35U

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

SF-05AU 1/2 0.4 2’’ 50 6 0.15 6 9 9.5 0.32 9.5 19.2 35 11/2’’ 15 33 14 31

SF-21AU 1 0.75 2’’ 50 8 0.2 8 12 12.5 0.4 12.5 24 35 11/2’’ 16 35 15 33

SF-32U 2 1.5 3’’ 80 8.5 0.4 8.5 24 12 0.9 12 54 35 11/2’’ 35 77

SF-33U 3 2.2 3’’ 80 10.5 0.5 10.5 30 16 1.1 16 66 35 11/2’’ 37 82

SF-35U 5 3.7 3’’ 80 15 0.5 15 30 21 1.1 21 66 38 11/2’’ 45 99

ModelP2 Discharge Phase 1 Ø 1 Ø 1 Ø 3 Ø 3 Ø 3 Ø 3 Ø m3/h 6 12 18 24 30 36 48 60

[HP] [kW] [inch] [mm] Voltage 220 V 230 V 240 V 230 V 380 V 400 V 415 V m3/min 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1

SF-05AU 1/2 0.4 2’’ 50

Full

loa

d a

mp

ere

3.4 3.3 3.2 2.3 1.4 1.3 1.3

mw

c

7.4 4.5 1

SF-21AU 1 0.75 2’’ 50 5.4 5.2 5 3.3 2 1.9 1.8 10.6 8 4.5

SF-32U 2 1.5 3’’ 80 6.1 3.6 3.5 3.4 11.4 10.5 9.6 8.5 7.1 5.5 2

SF-33U 3 2.2 3’’ 80 8.6 5.1 5 4.8 15.2 14.1 13 11.7 10.5 9 5.7 2

SF-35U 5 3.7 3’’ 80 14 8.4 8.2 7.7 20.2 19.2 18 16.6 15 13 8.5 3.1

Applications

Water drainage for industries, sanitary

sewer, single and multiple dwellings,

water drainage for chemical,

pharmaceutical and metal processing

factories. The series are suitable for

all light acid, corrosive and sea water

applications.

Features

Best estructure design, dry motor,

double mechanical seals, equipped with

auto-cut protector, cast stainless steel

body and cover, acid resisting silicon

carbide seals. Viton o rings are used

throughout the pump to give better

pump life in corrosive acid and

aggressive media.

67

Page 68: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

72

S Series Drainage

Stainless steel submersible pumps

Specifications Performance curves at 2900 rpm

Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications Corrosive / Food Procesing liquidis

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class B

Protection IP 68

Protector Auto - cut

Bearing Ball type

M. seal Double m.seals

Impeller Semi-open

Material

Upper cover SCS 14

Motor frame SUS 316

Main shaft SUS 316

M. seal

Casing SCS 14

Impeller SCS 14

Cable VCT or H07RN-F or SJOW/SOW

Optional

Hydraulic performance table

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

SF-32P 2 1.5 3’’ 80 8 0,45 8 27 16.5 0.8 16.5 48 35 11/2’’ 36 79

SF-33P 3 2.2 3’’ 80 9 0.6 9 36 20 1 20 60 30 11/4’’ 38 84

ModelP2 Discharge Phase 1 Ø 1 Ø 1 Ø 3 Ø 3 Ø 3 Ø 3 Ø m3/h 6 12 18 24 30 36 48

[HP] [kW] [inch] [mm] Voltage 220 V 230 V 240 V 230 V 380 V 400 V 415 V m3/min 0.1 0.2 0.3 0.4 0.5 0.6 0.8

SF-32P 2 1.5 3’’ 80

Full

loa

d

am

pe

re 6.1 3.6 3.5 3.4

mw

c 14.6 12.6 10.7 8.7 6.7 4.6

SF-33P 3 2.2 3’’ 80 8.6 5.1 5 4.8 18.5 16.8 15 13.1 11 9 4.5

SF-32P SF-33P

4842363024181260 Q [m3/h]

Q [m3/min]0.80.60.40.20

50

40

30

20

10

0

H

[ft]

H

[m]

16

12

8

4

0

U.S. g.p.m 80 120 160 200 240

Imp g.p.m 40 80 120 160 200

Applications

Water drainage for industries, sanitary

sewer, single and multiple dwellings,

water drainage for chemical,

pharmaceutical and metal processing

factories. The series are suitable for

all light acid, corrosive and sea water

applications.

Features

Best estructure design, dry motor,

double mechanical seals, equipped with

auto-cut protector, cast stainless steel

body and cover, acid resisting silicon

carbide seals. Viton o rings are used

throughout the pump to give better

pump life in corrosive acid and

aggressive media.

68

Page 69: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

73

AS Series Drainage

Submersible dewatering pumps

Applications

Civil engineering, dewatering of

tunnelling and ground works, also for

storm water drainage and dewatering of

fluids containing solid sediments.

Features

Complete stainless steel outer cover of

AS 1.5-10HP (1.1-7.5 kw) models provide

exceptional consolidated design, with

light weight structure of less than 80 kg

and a diameter of 286mm that provide a

miniature outlook.

Special designed high efficiency and

water resistant HiCr impeller 55-60 HRC.

Multi impeller design suitable form

high head with small capacity to

low head with large capacity

application requirements:

(H: high. N: normal, L: large).

Optional discharge connection

(hose, flange & thread connection).

Specifications Performance curves at 2900 rpm

Hydraulic performance table

Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications Construction sites / Basins Dewatering

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class B (5HP : Class F)

Protection IP 68

Protector Auto - cut

Bearing Ball type

M. seal Double m.seals

Impeller Semi-open

Material

Outer cover SUS 304

Upper cover FC-200

Motor frame SUS 304

Main shaft SUS 403

M. seal

Casing FC-200

Impeller HCR

Cable VCT or H07RN-F or SJOW/SOW (5HP/230 : SJOW)

Optional Float switch (AS-215)

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

AS-215 11/2 1.1 2’’ 50 13.5 0.2 13.5 12 19.5 0.4 19.5 24 7.5 1/4’’ 28 62 24 53

AS-32A 2 1.5 3’’ 80 10 0.4 10 24 17.5 0.7 17.5 42 10.5 1/2’’ 43 95 37 82

AS-33A 3 2.2 3’’ 80 14 0.4 14 24 22 0.8 22 48 10.5 1/2’’ 46 102 40 88

AS-35 5 3.7 3’’ 80 20 0.5 20 30 26.5 1.25 26.5 75 10.5 1/2’’ 44 97

ModelP2 Discharge Phase 1 Ø 1 Ø 1 Ø 3 Ø 3 Ø 3 Ø 3 Ø m3/h 6 12 18 24 30 36 42 72

[HP] [kW] [inch] [mm] Voltage 220 V 230 V 240 V 230 V 380 V 400 V 415 V m3/min 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1.2

AS-215 11/2 1.1 2’’ 50

Full

loa

d

am

pe

re

8.4 8.2 8 4.9 2.9 2.8 2.7

mw

c

17 13.5 8.3

AS-32A 2 1.5 3’’ 80 10.4 10 9.8 6.1 3.6 3.5 3.4 16.1 14.4 12.3 10 7.2 4 1.6

AS-33A 3 2.2 3’’ 80 15 14.6 14.4 8.6 5.1 5 4.8 20.5 18.6 16.4 14 11.4 8.3 4.6

AS-35 5 3.7 3’’ 80 14 8.4 8.2 7.7 25.6 24.4 23.2 21.7 20 18 16 2

AS-215 AS-32A AS-33A AS-35

60

40

20

0

H

[ft]

H

[m]

20

16

12

8

4

0

Q [m3/h]6660544842363024181260

Q [m3/min]10.80.60.40.20

U.S. g.p.m 80 120 160 200 240 280 320

Imp g.p.m 80 120 160 200 240

69

Page 70: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

74

AS Series Drainage

Submersible dewatering pumps

Specifications Performance curves at 2900 rpm

Hydraulic performance table

Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications Construction sites / Basins Dewatering

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class F

Protection IP 68

Protector Auto - cut

Bearing Ball type

M. seal Double m.seals

ImpellerSemi-open (80ASH25.5)

Encolosed-channel (100ASN25.5 & 10HP)

Material

Outer cover SUS 304

Motor frame FC-200

Main shaft SUS 420J2

M. seal

Casing FC-200

Impeller HCR

Wear ring HCR

Casing cover FC-200

Cable VCT or H07RN-F or SOW (10HP / 230 V : SJOW)

Optional

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

80ASH25.5 71/2 5.5 3’’ 80 28 0.5 28 30 38 1.3 38 78 10 1/2’’ 72 159

100ASN25.5 71/2 5.5 4’’ 100 19 1 19 60 29 2 29 120 10 1/2’’ 75 165

100ASN27.5 10 7.5 4’’ 100 25 1 25 60 39 1.8 39 108 10 1/2’’ 75 165

150ASL25.5 7.5 5.5 6’’ 150 12 1.5 12 90 25 2.4 25 144 10 1/2’’ 78 172

150ASL27.5 10 7.5 6’’ 150 17 1.5 17 90 30 2.7 30 162 10 1/2’’ 91 179

ModelP2 Discharge Phase 3 Ø 3 Ø 3 Ø 3 Ø m3/h 15 30 45 60 75 90 120 135

[HP] [kW] [inch] [mm] Voltage 230 V 380 V 400 V 415 V m3/min 0.25 0.5 0.75 1 1.25 1.5 2 2.25

80ASH25.5 71/2 5.5 3’’ 80

Full

loa

d a

mp

ere

20 11.8 11.6 11

mw

c

33.5 28 21 12.5 2.3

100ASN25.5 71/2 5.5 4’’ 100 20 11.8 11.6 11 36.7 33.5 29.7 24.8 19 12

100ASN27.5 10 7.5 4’’ 100 26.4 15.6 15.3 14.5 28 25.1 22.3 19 15.1 10.8

150ASL25.5 7.5 5.5 6’’ 150 20 11.8 11.6 11 23.5 21.5 19.5 17 14.6 12 5.8 2.4

150ASL27.5 10 7.5 6’’ 150 26.4 15.6 15.3 14.5 28.5 26.5 24.4 22 19.6 17 10.6 7

80ASH25.5

100ASN27.5

100ASN25.5

150ASL25.5

150ASL27.5

U.S. g.p.m 240120 360 480 600

Imp g.p.m 120 240 360 480

H

[m]

32

24

16

8

0

100

80

60

40

20

0

H

[ft]

1351201059075604530150 Q [m3/h]

Q [m3/min]21.510.50

Applications

Civil engineering, dewatering of

tunnelling and ground works, also for

storm water drainage and dewatering of

fluids containing solid sediments.

Features

Complete stainless steel outer cover of

AS 1.5-10HP (1.1-7.5 kw) models provide

exceptional consolidated design, with

light weight structure of less than 80 kg

and a diameter of 286mm that provide a

miniature outlook.

Special designed high efficiency and

water resistant HiCr impeller 55-60 HRC.

Multi impeller design suitable form

high head with small capacity to

low head with large capacity

application requirements:

(H: high. N: normal, L: large).

Optional discharge connection

(hose, flange & thread connection).

70

Page 71: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

75

Draincor Drainage

Submersible grinder pumps, for sewage water, with filaments

Applications

Drainage of sewage and dirty water,

operation in septic tanks and small

purifying installations.

Materials

Pump body, discharge body,

suction body and impeller in cast iron.

Dilacerative system in steel F-520.

Mechanical seal in silicon carbide

and graphite.

Pump base in stainless steel AISI 304,

detachable for coupling of accessories.

O-rings in NBR.

Motor shaft in stainless steel AISI 420.

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Water-cooled motor.

Single-phase version built-in thermal

protection and starting box with double

capacitor.

Equipment

11/2” BSP female threaded

discharge elbow.

Single-phase supplied

with capacitor box.

Draincor M: without float switch.

Draincor M A: with float switch.

Draincor T: three phase without float

switch.

Dimensions and weights

Draincor 180

Draincor 200

Model [Kg]A IHGFEDC

114.5

114.5

11/2”

11/2”

25

25

110

110

95.25

95.25

196

196

118.7

118.7

415.1

415.1

382.5

382.5

125

125

B

Performance curves at 2900 rpm

Hydraulic performance table

F

G

H

A B

C D

E

I

I [A]

1~

230 V

3~

400 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

1.5

25

3.0

50

6.0

100

9.0

150

10.5

175

12.0

200

15.0

250

7.8 2.8

3

1.7 1.6

1.8

1.1

1.25

1.5

1.7

16/50 18

21

16.7

19.7

13.7

17

10

14.1

7

12.6 11 7.3 2.5

17.4

290

mw

cDraincor 180

Draincor 200

180200

71

Page 72: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

76

Draincor Drainage

437

A

98

I

55

M

55

L

110

K

134

J

98

H

49

G

95

F

62

E

219

D

110

C

338

B

Portable version

H I

J

K

L

M

F

G

A

B

C D

E

G 2”

Draincor: without float switch. Draincor A: supplied built-in float switch

Fixed version, guide rail system

388

A

8

I

24

M

Ø10

L

50.5

K

12

J

52

H

60

G

112

F

60

E

168

D

110

C

353

B

209

N

12

V

60

Z

32

Y

13

X

40

W

94

U

120

T

98

S

98

R

Ø10

Q

85

P

Ø25

O

R S

T

U

Z

V

W

X

Y

F

G

HI

J

PQ

A

B

C D E

K

L

M

N

O

G 2”

Accessories

Draincor Drainage

Stationary version

DR1 Kit

Support base for

automatic anchoring.

Upper anchoring

on guide.

Clamping flange.

72

Page 73: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

77

GF Series Drainage

Submersible grinder pump

Applications

Pressure sewage systems, drainage of

sewage/wastewater from individual

residencies, apartment buildings etc.

The transfer of sewage/wastewater from

commercial buildings, industrial plants

and hospitals.

Features

Durable heavy duty finned cast iron

construction. Standard accesories

include exposy resin cable base, dry

motor, double mechanical seals,

auto-cut protection & double ball

bearing support shaft and rotor.

Vortex impeller desing prevents

clogging by cutting up articles.

Radial cutter & cutter ring.

Corrosion resistant material,

hardened to 55-60 Rockwell C.

Specifications Performance curves at 2900 rpm

Hydraulic performance table

32GF21.0

32GF21.5

32GF22.2 (1Ø)

32

GF2

2.2

(3Ø

)

50GF22.2

50GF23.7

80

60

40

20

0

H

[ft]

H

[m]

24

20

16

12

8

4

0

16.814.413.210.897.25.43.61.80 Q [m3/h]

Q [m3/min]0.240.180.120.060

U.S. g.p.m 20 30 40 50 60 70 80

Imp g.p.m 20 30 40 50 60 70Item Description

Limits of use

Liquid Temp. 0 - 40° C

Applications Residential wastewater and sewage

Submersion depth 100 feet (30 m)

Type

Frequency 50 Hz

Motor

Insulation Class B (5HP : Class F)

Protection IP 68

Protector Auto - cut

Bearing Ball type

M. seal Double m.seals

Impeller Vortex

Materials

Outer cover SUS 440C

Motor frame SUS 440C

Main shaft SUS 403

M. seal

Casing FC-200

Impeller FC-200

Cable VCT or H07RN-F or SJOW / SOW

Optional Float switch (5HP . none)

ModelP2 Discharge Standard MAX Solid Passage Weight (W/O Cable)

[HP] [kW] [inch] [mm] m m3/min m m3/h m m3/min m m3/h [mm] [kW] 1Ø Kg (Ib) 3Ø Kg (Ib)

32GF21.0 11/3 1 11/4’’ 32 17 0.06 17 3.6 20.5 0.13 20.5 7.8 28 62 25 55

32GF21.5 2 1.5 11/4’’ 32 23 0.06 23 3.6 26 0.15 26 9 36 79 33 73

32GF22.2 3 2.2 11/4’’ 321Ø:28

0.061Ø:28

3.6 32 0.165 32 9.9 38 84 35 773Ø:29 3Ø:29

50GF22.2 3 2.2 2’’ 50 19 0.2 19 12 25 0.33 25 19.8 51 113

50GF23.7 5 3.7 2’’ 50 26 0.2 26 12 31.5 0.33 31.5 19.8 53 117

ModelP2 Discharge Phase 1 Ø 1 Ø 1 Ø 3 Ø 3 Ø 3 Ø 3 Ø m3/h 1.8 3.6 7.2 9 10.8 14.4 16.2 18

[HP] [kW] [inch] [mm] Voltage 220 V 230 V 240 V 230 V 380 V 400 V 415 V m3/min 0.03 0.06 0.12 0.15 0.18 0.24 0.27 0.3

32GF21.0 11/3 1 11/4’’ 32

Full

loa

d a

mp

ere

6.6 6.4 6.4 4.1 2.4 2.4 2.3

mw

c

19.6 17 4

32GF21.5 2 1.5 11/4’’ 32 10.4 10 9.8 6.1 3.6 3.5 3.4 25.3 24 15.3

32GF22.2 (1Ø) 3 2.2 11/4’’ 32 15 14.6 14.4 8.6 5.1 5 4.8 30.2 28 19.1 8.6

32GF22.2 (3Ø) 3 2.2 11/4’’ 32 15 14.6 14.4 8.6 5.1 5 4.8 30.9 29 20.7 10.7

50GF22.2 3 2.2 2’’ 50 9.5 5.6 5.5 5.2 24.6 24.3 22.7 21.6 20.2 19.3 11.5 6.6

50GF23.7 5 3.7 2’’ 50 14 8.4 8.2 7.7 30.9 30.2 28.6 27.8 26.8 22.9 18.7 12.6

73

Page 74: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

78

Features

Control panel for 1 motor.

D.O.L. start.

Power supply 1~50/60 Hz 230 V ± 10%

(DRENA 1-Mono).

Power supply 3~50/60 Hz 400 V ± 10%

(DRENA 1-Tri).

Auxiliaries contacts and circuits in low

voltage.

Normally open contact for start.

Normally open contact for minimum

level/pressure/stop contact or input

for 3 levels probes.

Normally open contact for alarm

activation 12 Vcc 200 mA.

Normally open contact for clicson of

the motor.

Push-buttons for selecting Auto-Off/

Reset-Manual (temporary) operation.

Dip-switch selector for probes operating

in filling/emptying mode.

Green led indicating mains supply.

Green led indicating motor running.

Green led indicating automatic operation.

Red led indicating level alarm.

Red led indicating motor overload.

Red led indicating clicson alarm.

Adjustable overload electronic protection.

Auxiliaries and motor protection fuses.

Alarm output (com-no-nc resistive load).

Main switch interlocking door.

Running capacitor can be added

(not included).

Enclosure in ABS, IP 55

Ambient temperature: -5/+40 °C.

Relative humidity 50% at 40 °C

(not condensed).

Features

Control panel for 2 motors.

D.O.L. start.

Power supply 1~50/60 Hz 230 V ± 10%

(DRENA 2-Mono).

Power supply 3~50/60 Hz 400 V ± 10%

(DRENA 2-Tri).

Auxiliaries contacts and circuits in low

voltage.

N.2 normally open contact for start.

Normally open contact for minimum

level/pressure/stop.

Normally open contact for alarm

activation 12 Vcc 200 mA.

N.2 normally open contact for clicson

of the motor.

Running capacitor can be added

(not included).

Enclosure in ABS, IP 55.

Ambient temperature: -5/+40 °C.

Relative humidity 50% at 40 °C

(not condensed).

Push-buttons for selecting Auto-Off/

Reset-Manual (temporary) operation.

Motors’ exchanger with 5’’ delay.

Internal selector for exchanger exclusion.

Green led indicating mains supply.

N.2 Green led indicating motor running.

N.2 Green led indicating automatic

operation.

Red led indicating level alarm.

N.2 Red led indicating motor overload.

N.2 Red led indicating clicson alarm.

Adjustable overload electronic protection.

Auxiliaries and motor protection fuses.

Alarm output (com-no-nc resistive load).

Main switch interlocking door.

Control Panels Drainage

Control panels for sewage pump & stations

One Pump

Model Voltage [V]P2

Max [A] Height Lenght Width Weight [Kg][kW] [HP]

Drena 1-Mono 230 0.37 - 2.2 0.5 - 3 16 320 240 190 1.5

Drena 1-Tri/4 400 0.55 - 4 0.75 - 5.5 8 320 240 190 2

Drena 1-Tri/5.5 400 0.75 - 5.5 0.75 - 7.5 11 320 240 190 2

Drena 1-Tri/7.5 400 0.55 - 7.5 0.75 - 10 15 320 240 190 2.5

Drena 1-Tri/11 400 7.5 -11 10 - 15 24 320 240 190 3

Two Pump

Model Voltage [V]P2

Max [A] Height Lenght Width Weight [Kg][kW] [HP]

Drena 2-Mono 230 0.37 - 2.2 x 2 0.5 - 3 x 2 16 x 2 320 240 190 4

Drena 2-Tri/4 400 0.55 - 4 x 2 0.75 - 5.5 x 2 8 x 2 320 240 190 5.5

Drena 2-Tri/5.5 400 0.75 - 5.5 x 2 0.75 - 7.5 x 2 11 x 2 320 240 190 5.5

Drena 2-Tri/7.5 400 0.55 - 7.5 x 2 0.75 - 10 x 2 15 x 2 320 240 190 6.5

Drena 2-Tri/11 400 7.5 -11 x 2 10 - 15 x 2 24 x 2 380 300 190 6.5

74

Page 75: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

79

Drainbox 300/600 Drainage

Lifting stations for domestic applications

Innovation

Drainbox is the advanced, specific

solution created by ESPA for the

evacuation of water, from any source

(foul water, faecal, water, rainwater, etc.)

in all environments; domestic or

professional, rural or urban,

with complicated or unfavourable

drainage conditions.

Drainbox collects, stores, treats and

drives the water to the drainage level,

offering a series of truly outstanding

advantages in terms of versatility,

installation and performance.

Drainbox is based on simple, highly

effective drainage technology that

enables each pumping kit to be

customised with the type of pump that

is most suitable for the function and

services to be provided.

Drainbox is supplied with an innovative

tank, and a design that includes

a series of novel technical advantages

which add up to multiple services that

are accumulated for the purpose of

customising each installation. Customers

can select the input and output pipes,

ventilation pipes, emergency evacuation

system, retention valve, etc.

Drainbox 300

Drainbox 600

Model A C

770

1230

615

615

760

760

B

1 Tank cover - 2 Tank - 3 Drain plug

1

2

3

Applications

Domestic: detached homes, cottages,

rural properties, second homes, etc.

Professional: Restaurants, small hotels,

stores, workshops, small industries, etc.

Limitations

Maximum temperature of liquid: 40 °C.

Drainbox 300

A

B C

1 pump - 1 Tank of 300 liters - Packaging kit - Control Panel

Drainbox 600

A

B

C

2 pumps - 2 Tanks of 300 liters - Packaging kit - Control Panel

Dimensions and weights

75

Page 76: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

80

Drainbox 300/600 Drainage

Performance curves at 2900 rpm

Drainex 201/301 M/T

Vigicor 150 MVigilex M A

Characteristics table

I [A]

Modelo Pump

P1 [kW] P2

1~

230 V[kW]

1~

230 V

3~

400 V[HP]

3~

400 V

Ø Free

flows

Ø

Connection

Weight

[Kg]

Control

top panel

Q max.

[l/min]Impeller

3.4

5.4

6.2

6.2

6.8

0.8

1.2

1.4

1.4

1.5

0.6

0.9

1.1

2 x 1.1

1.1

-

-

2.6

2.6

2.7

-

-

1.4

1.4

1.5

0.8

1.2

1.5

2 x 1.5

1.5

24

45

45

60

11/4”

11/4”

2”

2”

2”

240

140

450

900

600

28.1

41

55

110

122

-

-

Top 1

Top 2

Top

Top

Vortex

Grinder

Vortex

Vortex

Vortex

Drainbox 300 800M A TP

Drainbox 300 1200M D TP FL

Drainbox 300 1400M TP KE FL

Drainbox 300 1400 TP KE FL

Drainbox 600 1400M TP KE FL

Drainbox 600 1400 TP KE FL

Drainbox 600 1500M TP KE FL

Drainbox 600 1500 TP KE FL

Vigilex 600 M A

Vigicor 150 M

Drainex 201M

Drainex 201

Drainex 201M

Drainex 201

Drainex 301M

Drainex 301

Accessories

Float switch kitNon return valveØ 63/Ø110 joint Extension

Ø100 elbow

male/female Ball valve

Packaging kitControl Panel Options (depending on model)

Wall boxControl top panel

Bolt x 2

Washer x 2

Joint Ø63 x 1

Instructions manual

Joint Ø110 x 1

Minimum flow for preventing particles from acculating in the pipes

H [m]

Q [m3/h]

Drainex 301Drainex 201Vigilex 600Vigicor 150

76

Page 77: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

81

Drainbox 600/1000/1250/1500 Drainage

Larger lifting/Sewage pump sets

Equipment

All packages come complete with

pipework pre-assembled in the chamber,

2 x 110 mm inlet rubbers (positioned &

cut on site to suit), standard pedestrian

access cover, ready for installation into

the ground, float brackets after which

the pumps and control equipment

are added.

All twin pump sets are supplied with a

control panel for fully automatic opera-

tion and a high level alarm beacon.

Chambers are available in different sizes:

-600, 1000, 1250 & 1500 mm diameter.

Larger diameters on request.

Choice of pumps from our Drainex/

Draincor/AL & GF range.

A control panel kiosk & tank extensions

(500 mm height) are available as an

optional extra.

Applications

Private housing, industry, commercial

premises, leisure complex, hotel,

motorway services and single

households.

Materials

Each pump chamber is made up of

strong, medium density polyethylene.

Typical twin pump installation diagram

Characteristics table

Model Pumps Pipework size Chamber size Pump installation

Drainbox 600FS/GR 1 - 2 50 - 65 mm 600 x 620/1000/1500/2000 Free standing / Guide rail

Drainbox 1000GR 1 - 2 50 - 65 mm 1000 x 1500/2000/2500 Guide rail

Drainbox 1250GR 2 50 - 80 mm 1250 x 2000 Guide rail

Drainbox 1500GR 2 50 - 100 mm 1500 x 2000/2500/3000 Guide rail

Single pump chamber

Twin pump chamber

77

Page 78: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

82

Drainbox 600/1000/1250/1500 Drainage

600 Series

Single pump systems 600 mm diameter

stations featuring a single freestanding

pump suitable for small drainage/

sewage applications.

Available in depths of:

600 mm (175 ltr).

1000 mm (280 ltr).

1500mm (420 ltr).

2000 mm (560 ltr).

Compatible pumps

1 1/4” - 1 1/2” - 2”

Features

Freestanding pump.

High level alarm (Optional).

Manhole cover.

Flexible pipework.

1000 Series

Single & dual pump systems 1000 mm

diameter stations featuring single or

dual pumps suitable for domestic

drainage/sewage applications.

Available in depths of:

1500mm (1100 ltr).

2000 mm (1500 ltr).

Compatible pumps

2” - 2 1/2” - 3”

Features

Freestanding / Guiderails.

High level alarm / Control panel & alarm.

Flexible / Fixed pipework.

Manhole cover.

1250 Series

Single & dual pump systems 1250 mm

diameter stations featuring single or

dual pumps suitable for larger domestic

sewage & drainage applications.

Available in depths of:

2000 mm (2400 ltr).

Compatible pumps

2” - 2 1/2” - 3”

Features

Guiderails.

Control panel & alarm.

Fixed pipework.

Manhole cover.

1500 Series

Single & dual pump systems 1500 mm

diameter stations featuring single or

dual pumps suitable for larger domestic,

commercial sewage & drainage

applications.

Available in depths of:

2000 mm (4500 ltr).

2500 mm (5600 ltr).

Compatible pumps

2” - 2 1/2” - 3” - 4”

Features

Guiderails.

Control panel & alarm.

Fixed pipework.

Manhole cover.

78

Page 79: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

83

WATER SUPPLY

SURFACE

HORIZONTAL &

VERTICAL

Page 80: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

84

Prisma 15/25 Surface Horizontal

Quiet-running multi-stage centrifugal pumps

Motor

Asynchronous, 2 poles.

IP 44 protection.

Class F insulation.

Continuous operation.

Single-phase version up to 1.5 HP

with built-in thermal protection.

Efficiency IE2.

Limitations

Maximum liquid temperature: 40 °C.

Applications

To work with clean water

in domestic applications, irrigation,

and hydropneumatic sets.

Self-priming to 2 m.

Materials

Pump body and impellers in AISI 304

stainless steel.

Motor shaft in AISI 420 stainless steel.

Diffusers in technopolymer.

Suction and discharge mountings

in cast iron.

Mechanical seal in graphite

and alumine.

Gaskets in EPDM and NBR.

Motor casing in aluminium.

Prisma 15

Dimensions and weights

Modelo A B C D E F G H I J Kg

Prisma 15 2 163 213 202 110 74 162 121 102 1” 1” 8.3

Prisma 15 3 187 237 202 110 74 162 121 102 1” 1” 9.2

Prisma 15 4 211 261 202 110 74 162 121 102 1” 1” 10

Prisma 15 5 235 285 202 110 74 162 121 102 1” 1” 11

Prisma 25 3/4/5

A

B

C D

E

F

G

H H

I

ØJ

Prisma 25 6

F

GA

B

C

D

E

HH

I

J

K

Prisma 25

Modelo A B C D E F G H I J K L M Kg

Prisma 25 3 202 127 252.5 82 75 109.5 218 59 138 8 1” 1” 13.5

Prisma 25 4 228.5 127 279 82 75 109.5 218 59 138 8 1” 1” 14.6

Prisma 25 5 255 127 328 82 75 109.5 240.5 59 138 8 1” 1” 17.2

Prisma 25 6 281 142 304 20 89.5 122 286 69 154 10 178 1” 1” 20

F

G

H

A

B

C

D

E

I

JPrisma 15

L L

M

M

80

Page 81: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

85

Prisma 15/25 Surface Horizontal

I [A]

1~

230 V 400 V230 V3~

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

1.20.6

2010

1.8

30

2.1

35

2.4

40

3.0

50

3,6

60

3.9

65

mw

c

Prisma 15 2

Prisma 15 3

Prisma 15 4

Prisma 15 5

Model

2

2.74

3.53

4.13

1.21

1.3

1.9

2.1

2.3

3.3

0.45

0.61

0.79

0.95

0.61

0.7

0.95

0.24

0.37

0.55

0.75

0.33

0.5

0.75

1.0

12

12

12

12

21

32

43

51

20

30

39

47

16.5

26

35

42

16

24

32

38

14

22

27

34

10.5

17

21.5

25

7

10.5

14

17

5

7

9

12

I [A]

1~

230 V 400 V230 V3~

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

1.80.9

3015

2.7

45

3.6

60

4.5

75

5.4

90

6.3

105

7.2

120

mw

c

Prisma 25 2

Prisma 25 3

Prisma 25 4

Prisma 25 5

Prisma 25 6

Model

4.3

5.5

6.8

7.4

9.8

2

2.5

3

3.9

3.5

4.3

5.2

6.7

0.9

1.2

1.5

1.7

2.2

1

1.4

1.7

2

0.55

0.75

0.92

1.1

1.5

0.75

1

1.25

1.5

2

16

16

16

25

30

22

33

43

56

72

21

32

42

55

68

20.5

30.5

40

52.5

65

19

28

37

48

58

17

26

33

43

50

15

22

28

37

40

12

17

22

29

32

8

12

15

20

24

Hydraulic performance table

Prisma 25Prisma 15

Performance curves at 2900 rpm

5

4

3

2

5

6

4

3

2

81

Page 82: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

86

Prisma 35N/45N Surface Horizontal

Prisma 35N

Prisma 45N

A

B

C

D

E

F

J J

G

H

I

K

A

B

C

D

E

F

J

G

H

I

K

J

Quiet-running multi-stage centrifugal pumps

Motor

Asynchronous, two poles.

IP 44 protection.

Class F insulation.

Continuous operation.

Efficiency IE2.

Limitations

Maximum liquid temperature: 40 °C.

Applications

For domestic and industrial supply.

Irrigation and hydropneumatic sets.

Materials

Pump body and impellers in stainless

steel AISI 304.

Motor shaft in stainless steel AISI 420.

Diffusers in tecnopolimer.

Suction and discharge mountings

in cast iron.

Mechanical seal in graphite

and alumine.

O-rings in EPDM and NBR.

Motor housing in aluminium.

Dimensions and weights

Prisma 35 3

Prisma 35 4

Prisma 35 5

Prisma 35 6

Model A

221.1

246.6

271.1

295.6

[Kg]

18.5/18.2

20.5/18.6

23.5/20.6

23.7

H J KG IFEDC

125.3

125.3

125.3

125.3

60

60

60

60

12

12

12

12

158

158

158

158

90

90

90

90

281.5

281.5

281.5

281.5

11/4”

11/4”

11/4”

11/4”

147

147

147

147

11/4”

11/4”

11/4”

11/4”

187.3

211.8

236.3

260.8

B

Prisma 45 3

Prisma 45 4

Prisma 45 5

Model A [Kg]

22.6/18.6

23.7/21.2

25.3

H J KG IFEDC

245.9

276.6

307.3

125.3

125.3

125.3

60

60

60

12

12

12

158

158

158

90

90

90

281.5

281.5

281.5

11/4”

11/4”

11/4”

152

152

152

11/2”

11/2”

11/2”

211.6

242.3

273

B

82

Page 83: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

87

Prisma 35N/45N Surface Horizontal

Prisma 35N Prisma 45N

Performance curves at 2900 rpm

Hydraulic performance table

5

6

4

3

5

4

3

I [A]

1~

230 V 400 V230 V3~

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

2.41.2

4020

3.6

60

4.8

80

6.0

100

7.2

120

8.4

140

6.7

8.4

10.2

2.6

3.1

4

4.8

4.5

5.3

6.9

8.3

1.5

1.8

2.3

1.4

1.8

2.2

2.7

0.8

1.1

1.5

2.2

1

1.5

2

3

25

25

30

41

54

68

81

39

51

64

78

36

48

60

74

34

44

55

67

31

39

49

60

27

33

41

52

22

27

34

42

18

23

30

37

9.0

150

mw

c

Prisma 35 3N

Prisma 35 4N

Prisma 35 5N

Prisma 35 6N

Model

I [A]

1~

230 V 400 V230 V3~

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

3.01.5

5025

4.5

75

6.0

100

7.5

125

9.0

150

12

200

7.9

10

3

4

5

5.2

6.9

8.6

1.8

2.2

1.7

2.2

2.8

1.1

1.5

2

1.5

2

3

25

30

37

48

61

36

47

59

35

45

56

33

42

54

30

39

50

27

36

45

18

24

31

8

11

15

15

250

mw

c

Prisma 45 3N

Prisma 45 4N

Prisma 45 5N

Model

83

Page 84: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

88

Prisma ESD Surface Horizontal

Pump with VFD built-in

Applications

Constant water supply in dripping

irrigation installations.

Industrial applications where constant

pressure is required.

Operation principle

The VFD increase and decrease

the speed of the motor according

the installation demand supplying

constant pressure.

The input signal comes from a pressure

transducer installed on the discharge

pipe.

Speedrive are manufactured with all the

protections in order to protect the pump,

from dry running, temperature, over

intensity, etc.

Voltage range

Low voltage: disconnect at 180 V (M2)

310 V (T2).

Automatic reset: 195 V (M2) 335 V (T2).

High voltage: disconnect at 270 V (M2)

485 V (T2).

Automatic reset: 250 V (M2) 475 V (T2).

Hydraulic performance table

Performance area Prisma ESDM at 2900 rpm

86420

140120100806040200 Q [l/min]

Q [m3/h]

10

10

20

20

30

30 40

Imp g.p.m.

U.S. g.p.m.

60

50

40

30

20

10

0

H

[mca]

200

150

100

50

0

H

[ft]

600

400

200

0

H

[kPa]

Q [l/min]

Performance area Prisma ESD at 2900 rpm

151050

300250200150100500

Q [m3/h]

20 40 60

20 40 60 80

Imp g.p.m.

U.S. g.p.m.

80

60

40

20

0

H

[mca]

800

600

400

200

0

H

[kPa]

250

200

150

100

50

0

H

[ft]

Model Pump UnitP2

VfdPump

[kW] Suction Discharge

Prisma ESD 25 4 Prisma 25 4 1 0.92 M2/T2 1” 1”

Prisma ESD 25 6 Prisma 25 6 1 1.5 M2/T2 1” 1”

Prisma ESD 35 4 Prisma 35 4 1 1.1 M2/T2 1 1/4” 1 1/4”

Prisma ESD 35 5 Prisma 35 5 1 1.5 M2/T2 1 1/4” 1 1/4”

Prisma ESD 35 6 Prisma 35 6 1 2.2 T2 1 1/4” 1 1/4”

Prisma ESD 45 4 Prisma 45 4 1 1.5 T2 1 1/2” 1 1/4”

Prisma ESD 45 5 Prisma 45 5 1 2 T2 1 1/2” 1 1/4”

Pressure transductor 4-20 mA (10 bar)

Materials and motor

As per the pump and Speedrive

pages.

Equipment

Pumps supplied with VDF integrated.

Pressure transducer included.

84

Page 85: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

89

Prisma ESD Surface Horizontal

Prisma ESD 25

Prisma ESD 35

Prisma ESD 45

Model A B C D E F G H I J Kg

Prisma ESD 25 4M 228.5 279 225 82 127 207 213 75 59 Ø8 16.5

Prisma ESD 25 4T 228.5 279 225 82 127 207 213 75 59 Ø8 16.5

Prisma ESD 25 6M 281 328 225 82 127 207 213 75 59 Ø8 19.3

Prisma ESD 25 6T 281 328 225 82 127 207 213 75 59 Ø8 19.3

Dimensions and weights

A

B

C

D

E

F

G

H

I I

J

G 1

” IS

O 2

28

/1

G 1” ISO 228/1

A

B

C

D

E

F

G

H

I

G 1

1/4

” IS

O 2

28

/1

G 1 1/4” ISO 228/1

H

A

B

C

D

E

F

G

H

I

G 1

1/2

” IS

O 2

28

/1

G 1 1/4” ISO 228/1

H

Model A B C D E F G H I Kg

Prisma ESD 35 4M 246.6 211.8 280.5 147 212 90 207 60 Ø12 22.6

Prisma ESD 35 4T 246.6 211.8 280.5 147 212 90 207 60 Ø12 20.9

Prisma ESD 35 5M 271.1 236.3 280.5 147 212 90 207 60 Ø12 25.6

Prisma ESD 35 5T 271.1 236.3 280.5 147 212 90 207 60 Ø12 22.9

Prisma ESD 35 6T 295.6 260.8 280.5 147 212 90 207 60 Ø12 26

Model A B C D E F G H I Kg

Prisma ESD 45 4M 276,6 242,3 281,5 152 221 90 207 60 Ø12 25,8

Prisma ESD 45 4T 276,6 242,3 281,5 152 221 90 207 60 Ø12 23,5

Prisma ESD 45 5T 307,3 273 281,5 152 221 90 207 60 Ø12 27,5

85

Page 86: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

90

Aspri 15/25 MB Surface Horizontal

Quiet-running multi-stage centrifugal pumps

Motor

Asynchronous, two poles.

IP 44 protection.

Class F insulation.

Continuous operation.

Single-phase with built-in thermal

protection.

Efficiency IE2.

Limitations

Maximum suction lift: 9 m.

Maximum liquid temperature: 40 °C.

Applications

To work with clean water in domestic

applications, irrigation,

and hydropneumatic sets.

Materials

Pump body and impellers in stainless

steel AISI 304.

Motor shaft in stainless steel AISI 420.

Diffusers in technopolymer.

Suction and discharge connections

in brass.

Mechanical seal in graphite and alumine.

Motor housing in aluminium.

Built-in self priming valve.

O-rings in EPDM and NBR

Aspri 15 MB

Dimensions and weights

Modelo A B C D E F G H I J Kg

Aspri 15 3 MB 187 237 202 110 74 162 121 102 1” 1” 9.2

Aspri 15 4 MB 211 261 202 110 74 162 121 102 1” 1” 10

Aspri 15 5 MB 235 285 202 110 74 162 121 102 1” 1” 11

Aspri 25 MB

Modelo A B C D E F G H I J L M Kg

Aspri 25 3 MB 202 127 252.5 82 75 109.5 218 59 138 8 1” 1” 13.5

Aspri 25 4 MB 228.5 127 279 82 75 109.5 218 59 138 8 1” 1” 14.6

Aspri 25 5 MB 255 127 328 82 75 109.5 240.5 59 138 8 1” 1” 17.2

F

G

H

A

B

C

D

E

I

JAspri 15 MB

Aspri 25 MB

A

B

C D

E

F

G

H H

I

ØJ

L

M

86

Page 87: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

91

Aspri 15/25 MB Surface Horizontal

Performance curves at 2900 rpm

Aspri 15 MB Aspri 25 MB

Hydraulic performance table

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

0.60.3

105

1.2

20

1.8

30

2.1

35

2.4

40

3.0

50

2.74

3.53

4.13

1.21

1.3

1.9

2.1

2.3

3.3

0.61

0.7

0.95

0.61

0.7

0.95

0.37

0.55

0.75

0.5

0.75

1.0

12

12

12

33

44

53

32

43

51

30

39

47

26

35

42

24

32

38

22

27

34

17

21.5

25 17

3.6

60

mw

c

Aspri 15 3 MB

Aspri 15 4 MB

Aspri 15 5 MB

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

1.80.9

3015

2.7

45

3.6

60

4.5

75

5.4

90

6.3

105

5.5

6.8

7.4

2

2.5

3

3.5

4.3

5.2

1.2

1.5

1.7

1

1.4

1.7

0.75

0.92

1.1

1

1.25

1.5

16

16

25

33

43

56

32

42

55

30.5

40

52.5

28

37

48

26

33

43

22

28

37

17

22

29

14.5

20

7.2

120

mw

c

Aspri 25 3 MB

Aspri 25 4 MB

Aspri 25 5 MB

4

5

3

4

5

3

87

Page 88: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

92

Aspri 35N/45N Surface Horizontal

Quiet-running multi-stage centrifugal pumps

Applications

To work with clean water in domestic

and industrial applications, irrigation,

and hydropneumatic sets.

Materials

Pump body and impellers in stainless

steel AISI 304.

Diffusers in technopolymer.

Suction and discharge connections

in cast iron.

Mechanical seal in graphite and alumine.

Built-in self priming valve.

O-rings in EPDM and NBR.

Aspri 35N:

Motor shaft in stainess steel AISI 420

and steel F-114.

Motor housing in aluminium L-2521.

Aspri 45N:

Motor shaft in stainess steel AISI 420.

Motor housing in aluminium L-2521.

Dimensions and weights

Aspri 35 3

Aspri 35 4

Aspri 35 5

Aspri 35 6

Model A

221.1

246.6

271.1

295.6

[Kg]

18.5/18.2

20.5/18.6

23.5/20.6

23.7

H J KG IFEDC

125.3

125.3

125.3

125.3

60

60

60

60

12

12

12

12

158

158

158

158

90

90

90

90

281.5

281.5

281.5

281.5

11/4”

11/4”

11/4”

11/4”

147

147

147

147

11/4”

11/4”

11/4”

11/4”

187.3

211.8

236.3

260.8

B

Aspri 35N

Aspri 45 3

Aspri 45 4

Aspri 45 5

Model A [Kg]

22.6/18.6

23.7/21.2

25.3

H J KG IFEDC

245.9

276.6

307.3

125.3

125.3

125.3

60

60

60

12

12

12

158

158

158

90

90

90

281.5

281.5

281.5

11/4”

11/4”

11/4”

152

152

152

11/2”

11/2”

11/2”

211.6

242.3

273

B

Aspri 45N

A

B

C

D

E

F

J J

G

H

I

K

A

B

C

D

E

F

J

G

H

I

K

J

Motor

Asynchronous, two poles.

IP 44 protection.

Class F insulation.

Continuous operation.

Efficiency IE2.

Limitations

Maximum suction lift: 9 m.

Maximum temperature of liquid: 40 °C.

88

Page 89: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

93

Aspri 35N/45N Surface Horizontal

Performance curves at 2900 rpm

Aspri 35N Aspri 45N

Hydraulic performance table

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

2.41.2

4020

3.6

60

4.8

80

6.0

100

7.2

120

8.4

140

6.7

8.4

10.2

2.6

3.1

4

4.8

4.5

5.3

6.9

8.3

1.5

1.8

2.3

1.4

1.8

2.2

2.7

0.8

1.1

1.5

2.2

1

1.5

2

3

25

25

30

41

54

68

81

39

51

64

78

36

48

60

74

34

44

55

67

31

39

49

60

27

33

41

52

22

27

34

42

18

23

30

37

9.0

150

mw

c

Aspri 35 3 N

Aspri 35 4 N

Aspri 35 5 N

Aspri 35 6 N

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

3.01.5

5025

4.5

75

6.0

100

7.5

125

9.0

150

12

200

7.9

10

3

4

5

5.2

6.9

8.6

1.8

2.2

1.7

2.2

2.8

1.1

1.5

2

1.5

2

3

25

30

37

48

61

36

47

59

35

45

56

33

42

54

30

39

50

27

36

45

18

24

31

8

11

15

15

250

mw

c

Aspri 45 3 N

Aspri 45 4 N

Aspri 45 5 N

4

5

3

4

5

6

3

89

Page 90: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

94

Aspri ESD B Surface Horizontal

Pump with VFD built-in

Applications

Constant water supply in dripping

irrigation installations.

Industrial applications where constant

pressure is required.

Operation principle

The VFD increase and decrease

the speed of the motor according

the installation demand supplying

constant pressure.

The input signal comes from a pressure

transducer installed on the discharge

pipe.

Speedrive are manufactured with all the

protections in order to protect the pump,

from dry running, temperature, over

intensity, etc.

Voltage range

Low voltage: disconnect at 180 V (M2)

310 V (T2).

Automatic reset: 195 V (M2) 335 V (T2).

High voltage: disconnect at 270 V (M2)

485 V (T2).

Automatic reset: 250 V (M2) 475 V (T2).

Performance area Aspri ESDM B at 2900 rpm

86420

140120100806040200 Q [l/min]

Q [m3/h]

10

10

20

20

30

30 40

Imp g.p.m.

U.S. g.p.m.

60

50

40

30

20

10

0

H

[mca]

200

150

100

50

0

H

[ft]

600

400

200

0

H

[kPa]

Q [l/min]

Performance area Aspri ESD B at 2900 rpm

151050

300250200150100500

Q [m3/h]

20 40 60

20 40 60 80

Imp g.p.m.

U.S. g.p.m.

80

60

40

20

0

H

[mca]

800

600

400

200

0

H

[kPa]

250

200

150

100

50

0

H

[ft]

Hydraulic performance table

Model Pump UnitP2

VfdPump

[kW] Suction Discharge

Aspri ESD 15 5 B Aspri 15 5 B 1 0.75 M2 1” 1”

Aspri ESD 25 4 B Aspri 25 4 1 0.92 M2 1” 1”

Aspri ESD 25 5 B Aspri 25 5 1 1.1 M2/T2 1” 1”

Pressure transducer 4-20 mA (10 bar)

Materials and motor

As per the pump and Speedrive

pages.

Equipment

Pumps supplied with VDF integrated.

Pressure transducer included.

90

Page 91: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

95

Aspri ESD B Surface Horizontal

Dimensions and weights

Aspri ESD 15 B

Model A B C D E F G H I J Kg

Aspri ESD 15 B 5M 235 285 202 74 110 207 220 73 51 Ø8 13

Aspri ESD 15 B 5T 235 285 202 74 110 207 220 73 51 Ø8 13

A

B

C

D

E

F

G

H

I I

J

G 1

” IS

O 2

28

/1

G 1” ISO 228/1

Aspri ESD 25 B

Model A B C D E F G H I J Kg

Aspri ESD 25 B 4M 228,5 279 225 82 127 207 213 75 59 Ø8 16,5

Aspri ESD 25 B 4T 228,5 279 225 82 127 207 213 75 59 Ø8 16,5

Aspri ESD 25 B 5M 255 328 240 82 127 207 227 79 59 Ø8 18

Aspri ESD 25 B 5T 255 328 240 82 127 207 227 79 59 Ø8 18

A

B

C

D

E

F

G

H

I I

J

G 1

” IS

O 2

28

/1

G 1” ISO 228/1

91

Page 92: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

96

Tecno/Tecnoself Surface Horizontal

Quiet-running horizontal multi-stage centrifugal pumps

Motor

Asynchronous, two poles.

IP 55 protection.

Class F insulation.

Continuous operation.

Efficiency IE2.

Tecno 05: Built-in thermal protection.

Tecno/Tecnoself 15: Single-phase ver-

sion with built-in thermal protection.

Tecno 25: Single-phase version up to

1.25 HP with built-in thermal protection.

Applications

To work with clean water in domestic

applications, irrigation, and pressure

sets.

Materials

Pump body and impellers in stainless

steel AISI 304.

Diffusers in technopolymer.

Mechanical seal in graphite and steatite.

Tecno 05:

O-rings in EPDM and NBR.

Pump base, motor flange and motor

housing in aluminium.

Tecno/Tecnoself 15/25:

Motor shaft in stainess steel AISI 431.

Motor housing in aluminium.

Gaskets in EPDM/NBR.

Limitations

Maximum temperature of liquid: 40 °C.

Tecnoself 15/25: Self-priming up to 9 m.

Dimensions and weights

Tecno 05 2

Tecno 05 3

Tecno 05 4

Tecno 15 3

Tecno 15 4

Tecno 15 5

Tecno 25 3

Tecno 25 4

Tecno 25 5

Tecnoself 15 3

Tecnoself 15 4

Tecnoself 15 5

Tecnoself 25 3

Tecnoself 25 4

Tecnoself 25 5

Model A

80

80

80

197.4

220.7

244

210

236.6

263.2

197.4

220.7

244

210

236.6

263.2

[Kg]

5.2

6.2

6.3

7.2

9.5

11

7.2

9.5

11

7.2

9.5

11

7.2

9.5

11

H

225

225

225

88

88

88

88

88

88

88

88

88

88

88

88

J

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

K

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

G

123.8

141.7

159

148.5

148.5

148.5

196.3

196.3

196.3

148.5

148.5

148.5

196.3

196.3

196.3

I

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

F

174

174

174

196.3

196.3

196.3

148.5

148.5

148.5

196.3

196.3

196.3

148.5

148.5

148.5

E

176.3

194.2

211.5

232.5

232.5

232.5

190.5

190.5

190.5

232.5

232.5

232.5

190.5

190.5

190.5

D

94

94

94

181.5

181.5

181.5

267

267

288.5

181.5

181.5

181.5

267

267

288.5

C

157.5

157.5

157.5

258

281.3

304.6

271.5

298.1

324.7

258

281.3

304.6

271.5

298.1

324.7

136

136

136

107.5

107.5

107.5

107.5

107.5

107.5

107.5

107.5

107.5

107.5

107.5

107.5

BTecno 05

K

J

HG

F

E

D

A

I

C

B

Tecno 15 / Tecnoself 15

A

K

J

E

D

C

B

H

G

F

ØI

Tecno 25 / Tecnoself 25

ØIH

G

FA

K

JE

D

C

B

92

Page 93: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

97

Tecno/Tecnoself Surface Horizontal

Hydraulic performance table

1.2

1.6

2

0.25

0.35

0.45

0.11

0.19

0.19

0.15

0.25

0.25

6

6

6

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

17.7

27.5

36

0.3

5

16.7

26

33.5

0.6

10

14.9

23.2

30

0.9

15

12.7

20.1

26.5

1.2

20

10.2

17.2

21.5

1.5

25

7.4

12.5

16

1.8

30

3

7.4

10

2.1

35

1

4

7

2.25

37.5

mw

c

Tecno 05 2

Tecno 05 3

Tecno 05 4

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

1.20.6

2010

1.8

30

2.1

35

2.4

40

3.0

50

3.6

60

2.74

3.53

4.13

1.21

1.3

1.9

2.1

2.3

3.3

0.37

0.55

0.75

0.5

0.75

1.0

0.61

0.79

0.95

0.61

0.7

0.94

12

12

12

32

43

51

30

39

47

26

35

42

24

32

38

22

27

34

17

21.5

25

10.5

14

17

7

9

12

3.9

65

mw

c

Tecno / Tecnoself 15 3

Tecno / Tecnoself 15 4

Tecno / Tecnoself 15 5

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

1.80.9

3015

2.7

45

3.6

60

4.5

75

5.4

90

6.3

105

5.5

6.8

8.2

2.5

3

4.3

5.2

0.75

0.92

1.1

1

1.25

1.5

1.2

1.5

1.8

1

1.4

1.7

16

16

25

33

43

56

32

42

55

30.5

40

52.5

28

37

48

26

33

43

22

28

37

17

22

29

12

15

20

7.2

120

mw

c

Tecno / Tecnoself 25 3

Tecno / Tecnoself 25 4

Tecno / Tecnoself 25 5

Performance curves at 2900 rpm

Tecno 05 Tecno 15 / Tecnoself 15

Tecno 25 / Tecnoself 25

4

5

3

4

5

3

3

4

2

93

Page 94: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

98

Tecno ESD Surface Horizontal

Pump with VFD built-in

Applications

Constant water supply in dripping

irrigation installations.

Industrial applications where constant

pressure is required.

Operation principle

The VFD increase and decrease

the speed of the motor according

the installation demand supplying

constant pressure.

The input signal comes from a pressure

transducer installed on the discharge

pipe.

Speedrive are manufactured with all the

protections in order to protect the pump,

from dry running, temperature, over

intensity, etc.

Voltage range

Low voltage: disconnect at 180 V (M2)

310 V (T2).

Automatic reset: 195 V (M2) 335 V (T2).

High voltage: disconnect at 270 V (M2)

485 V (T2).

Automatic reset: 250 V (M2) 475 V (T2).

Performance area Tecno ESDM at 2900 rpm

86420

140120100806040200 Q [l/min]

Q [m3/h]

10

10

20

20

30

30 40

Imp g.p.m.

U.S. g.p.m.

60

50

40

30

20

10

0

H

[mca]

200

150

100

50

0

H

[ft]

600

400

200

0

H

[kPa]

Q [l/min]

Performance area Tecno ESD at 2900 rpm

151050

300250200150100500

Q [m3/h]

20 40 60

20 40 60 80

Imp g.p.m.

U.S. g.p.m.

80

60

40

20

0

H

[mca]

800

600

400

200

0

H

[kPa]

250

200

150

100

50

0

H

[ft]

Hydraulic performance table

Model Pump UnitP2

VfdPump

[kW] Suction Discharge

Tecno ESD 15 5 Tecno 15 5 1 0,75 M2/T2 1” 1”

Tecno ESD 25 4 Tecno 25 4 1 0,92 M2/T2 1” 1”

Tecno ESD 25 5 Tecno 25 5 1 1,1 M2/T2 1” 1”

Pressure transductor 4-20 mA (10 bar)

Materials and motor

As per the pump and Speedrive

pages.

Equipment

Pumps supplied with VDF integrated.

Pressure transducer included.

94

Page 95: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

99

Tecno ESD Surface Horizontal

Tecno ESD 15

Tecno ESD 25

Model A B C D E F G H I DNa DNd Kg

Tecno ESD 15 5 244 107.5 304.6 262 272 196.3 207 88 9 G1’’ G1’’ 13.2

Model A B C D E F G H I DNa DNd Kg

Tecno ESD 25 4 236.6 107.5 298.1 270 272 196.3 207 88 9 G1’’ G1’’ 14.9

Tecno ESD 25 5 263.2 107.5 324.7 270 272 196.3 207 88 9 G1’’ G1’’ 16.2

Dimensions and weights

F

B

DNa

DNd

C

A

D

E G

HI

F

B

DNa

DNd

C

A

D

E G

HI

95

Page 96: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

104

Per Surface Horizontal

Peripheral pump for espres pressurisation units

Hydraulic performance table

Dimensions and weights Performance curves at 2900 rpm

Model

I

[A]P2 c l/min 5 10 20 30 40

1~

230 V[kW] [HP] [μF] m3/h 0.3 0.6 1.2 1.8 2.9

Per 50 2.1 0,37 0,5 12

mw

c

35 30 21 13 5

Model A B C D E F G H I L M DNA DNM [Kg]

Per 50 67 20 265 125 125 155 63 143 265 145 165 1’’ 1’’ 5.7

Applications

Peripheral positive displacement

pumps with frontal pumps for small

household systems and simple

industrial applications; characterised

by a considerable ratio between

performance and required output.

Motor

Class F insulation.

IP 44 protection.

Continuous operation.

Single-phase with built-in thermal

protection.

Materials

Pump body in bronze.

Impeller in brass.

Motor shaft in stainless steel AISI 416.

Mechanical seal in graphite

and ceramic.

Limitations

Maximum temperature of liquid: 60 °C.

96

Page 97: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

105

Applications

Pumping of clean non-loaded fluids

for the domestic, agricultural & industrial

markets. Boosting, irrigation, water

treatment, heating and air conditioning

& washing systems.

Description

Closed coupled and compact, silent

excellent efficiency that allows a

reduction of running cost and power.

Economical, over dimensioned bearings

for longer life of the pumps.

Intermediate shaft guiding stage for

concentricity of rotation.

Motor

IP 44 protection.

Class F insulation.

Continuous operation.

Single phase with built-in thermal

protection.

PQ Surface Horizontal

Peripheral pump for espres pressurisation units

Limitations

Liquid temperature range -15 to +110 °C.

Ambient temperature max 40 °C.

Water mixed with glycol, parameters

must be checked with over 20% of

glycol. Pure non-explosive liquid media

free from mineral oils and without solids.

Maximum working pressure 10 bar.

Hydraulic performance table

Dimensions and weights Performance curves at 2900 rpm

Model

I

[A]P2 c l/min 5 10 20 30

1~

230 V[kW] [HP] [μF] m3/h 0.3 0.6 1.2 1.8

PQAm 60 2.5 0.37 0.5 10

mw

c

35 29 18 7

PQ81-81BsPQAm 60

Model

I

[A]P2 c l/min 2 4 6 8 10 12 14 16 18

1~

230 V[kW] [HP] [μF] m3/h 0.12 0.24 0.4 0.5 0.6 0.7 0.8 1 1.08

PQm 81Bs 3.4 0.5 0,7 14

mw

c

80 71 63 54 45 37 28 19 10

Model a f h h1 h2 h3 i m n n1 w s DNA DNM [Kg]

PQAm60 25 192 145 96 33 129 72.5 55 118 96 53 7 1/2’’ 1/2’’ 4.7

PQm81Bs 18 220 152 119 23 141 71 80 120 100 58 7 1/2’’ 1/2’’ 6.5

97

Page 98: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

106

Applications

To supply clean water in domestic

applications, irrigation, hydropneumatic.

Pressure sets and for applications.

Requiring a self-priming pump.

Materials

Pump body and motor support in cast

iron.

Impeller in Noryl or brass.

Mechanical seal in ceramic-graphite.

Shaft in AISI 416.

Motor

Class F insulation.

IP 44 protection.

Continuous operation.

Single phase with built-in thermal

protection.

Jet JA Surface Horizontal

Self priming jet pump

Limitations

Liquid temperature range 0 - 50 °C.

Ambient temperature max 40 °C.

Maximum working pressure 6 bar.

Maximum suction lift 9 m.

Hydraulic performance table

Model

I

[A]

P1

[kW]P2 c l/min 10 20 30 40 50 60 70 80

1~

230 V

3~

400 V

1~

230 V

3~

400 V[kW] [HP] [μF] m3/h 0.6 1.2 1.8 2.4 3 3.6 4.2. 4.8

JA 60 3 1 0.63 0.59 0.44 0.6 12.5

mw

c

35 29.5 24 20

JA 80 3.6 1.3 0.79 0.78 0.59 0.8 14 42 36 30 25

JA 100 4.7 2.3 1.02 1.05 0.74 1 20 47 42 37 32 27 10

JA 110 4.7 2.3 1.02 1.05 0.74 1 20 36.5 33.9 30.8 27.7 24.5 22 20 18

Performance curves at 2900 rpm

JA 60JA 80

JA 100 JA 110

150

100

50

0

H

[ft]

H

[m]

40

50

30

20

10

0

543210 Q [m3/h]

Q [l/1’]706050403020100 80

Imp. g.p.m 5 10 15 20

U.S g.p.m 5 10 15 20 25

JA150

JA200JA300

H

[m]

60

50

40

30

20

200

150

100

H

[ft]

876543210 Q [m3/h]

Q [l/1’]120100806040200 140

Imp. g.p.m 10 15 20 25 30 35

U.S g.p.m 10 15 20 25 30 35 40

Model

I

[A]

P1

[kW]P2 c l/min 20 30 50 70 90 110 130 140

1~

230 V

3~

400 V

1~

230 V

3~

400 V[kW] [HP] [μF] m3/h 1.2 1.8 3 4.2 5.4 6.6 7.8 8.4

JA 150 7.9 3.3 1.74 1.68 1.1 1.5 31.5

mw

c

56.5 54 48 41 32

JA 200 10.3 3.9 2.22 2.1 1.65 2.2 36 59.5 58 54 49 43 34

JA 300 11.8 4.9 2.65 2.5 2.2 3 40 62 60.5 57 53 47 42 35 32

98

Page 99: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

108

Applications

To work with clean water.

Irrigation and hydropneumatic sets.

Motor

Asynchronous, two poles.

IP 44 protection.

Class F insulation.

Continuous operation.

Single-phase version with built-in

thermal protection.

Provided with removable handle

for transport.

Limitations

Maximum suction lift: 9 m.

Maximum temperature of liquid: 40 °C.

Delta Surface Horizontal

Self-priming centrifugal pumps with Venturi system up to 9 m

Materials

Pump body in stainless steel AISI 304.

Motor shaft in stainless steel AISI 420.

Diffusers in glass loaded Noryl®.

Mechanical seal in graphite and steatite.

Motor housing in aluminium L-2521.

Windings impregnated with epoxy resin.

Delta 505/755/1005:

Impeller in glass loaded Noryl®.

Delta 1755:

Impeller in stainless steel AISI 304.

Hydraulic performance table

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

0.90.3

155

1.5

25

2.1

35

2.4

40

3.0

50

3.6

60

2.8

3.4

4.8

5.5

1.2

1.3

1.9

2.1

2.2

2.6

3.3

3.8

0.6

0.8

1.0

1.2

0.6

0.8

1.0

1.2

0.37

0.5

0.75

0.75

0.5

0.75

1.0

1.0

12

12

16

16

33

37

47

57

26

32

40

55

22

27

34

51

18

23

29

47

17

21

27

44

13

17

38 32 21

4.5

75

mw

c

Delta 505

Delta 755

Delta 1005

Delta 1755

Dimensions and weights Performance curves at 2900 rpm

Delta 505

Delta 755

Delta 1005

Delta 1755

Model A

336

336

359

410

[Kg]

6.8

7.3

9.6

12.1

H

215

215

225

225

J

126

126

126

126

K

147

147

147

147

G

22

22

22

22

I

94

94

94

94

F

78

78

78

125

E

1”

1”

1”

1”

D

200

200

200

200

C

280

280

280

280

184

184

184

184

B

A

H

G

F

ED

C

E

K

JI

B

1755

1005

755

505

99

Page 100: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

109

Applications

Recycling plants, heating, air conditioning,

heat recovery, plants of water supply

procurement, pressure boosting and fire

fighting systems.

Materials

Pump body in cast iron.

Impeller in cast iron (option for bronze

or stainless steel).

Seal holding cover in cast iron (option

for bronze or stainless steel).

Shaft in stainless steel.

Energy Index MEI 0.1 to 0.4

Description

The FN pump is a monoblock centrifugal

pump with standardised dimensions in

accordance with the EN 733 standard.

Options

Different mechanical seals.

Frequency 60 Hz.

Counter flange kits. PN 10/PN16.

FN/FN4 Surface Horizontal

Cast iron close coupled end suction pumps

Motor

IP 55 protection.

Class F insulation.

Continuous operation.

Efficiency IE2.

Standard tensions: 220-240 V

up to 4kW, 380-415 V/660-720 V

starting from 5.5 kW.

Frequency: 50 Hz.

Limitations

Liquid temperature range -15 to +120 °C.

Ambient temperature max 40 °C.

Water mixed with glycol, parameters

must be checked with over 20% of

glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Field of application at 2900 rpm

FN

FN 4

Curves obtained in accordance with ISO9906, appendix A

100

Page 101: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

110

FN 32 Surface Horizontal

Hydraulic performance table

ModelP2 l/min 0 67 100 133 167 200 233 267 300 333 417 500 583 667

[kW] [HP] m3/h 0 4 6 8 10 12 14 16 18 20 25 30 35 40

FN 32-125C 0.75 1m

wc

17 16.6 16 15.3 14.3 13.2 11.8 10.3

FN 32-125B 1.1 1.5 21 20.6 20.1 19.2 17.8 15.8 14.1 12.3

FN 32-125A 1.5 2 25.4 25 24.6 24.1 23.2 22 20.5 18.8 16.9 15

FN 32-160C 1.5 2 28 27.4 27 26.3 25.6 24.8 23.4 22.3 20.7 18.5

FN 32-160B 2.2 3 33 32.2 32 31 30.2 29.2 28 27 25 23.2

FN 32-160A 3 4 37 36.5 36 35.4 34.7 33.8 32.8 31.6 30.1 28.3

FN 32-160NC 3 4 29 29 28.8 28.3 27.5 26.2 25.8 25.5 22.3 18.5

FN 32-160NB 4 5.5 36.4 36.4 36.2 35.8 35.4 34.7 34 33.2 31 27.5 23

FN 32-160NA 5.5 7.5 43 42.4 42.2 41.9 41.3 41 40.5 39.8 38 34.5 31.1 26

FN 32-200N 4 5.5 56.3 54.7 54 53 51.7 50.2 48.6

FN 32-200NC 4 5.5 46 45 44 43 41.3 39.8 38.2 36.2 34.4 27.5

FN 32-200NB 5.5 7.5 53.6 53 52.8 52.5 51.7 51.1 50.2 49.8 47.4 43 35

FN 32-200NA 7.5 10 63 62.8 62.6 62.5 62.3 62.2 62 60.6 59.5 57.5 49.7 38.6

FN 32-250E 7.5 10 64 63 62.6 62.4 61.8 61.3 60.9 59 56

FN 32-250D 9.2 12.5 70 69.8 69.6 69.3 69.9 68.4 68.1 67.3 65.3 63

FN 32-250C 11 15 76.3 76.3 76 75.7 75.3 74.8 74.4 73.8 71.4 69.8

FN 32-250B 13.5 18.3 86 83.5 83 82.2 81.9 81.3 80.8 80 79.2 75 55

FN 32-250A 17 23 94 92 91 90.5 90 89.5 89 88.4 87.3 86 66

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN 32-125C 32 50 336 80 100 70 190 140 112 140 14 50 27

FN 32-125B 32 50 336 80 100 70 190 140 112 140 14 50 28

FN 32-125A 32 50 373 80 100 70 190 140 112 140 14 50 29

FN 32-160C 32 50 373 80 100 70 240 190 132 160 14 50 33

FN 32-160B 32 50 370 80 100 70 240 190 132 160 14 50 34

FN 32-160A 32 50 397 80 100 70 240 190 132 160 14 50 35

FN 32-160NC 32 50 407 80 100 70 240 190 132 160 14 50 49

FN 32-160NB 32 50 426 80 100 70 240 190 132 160 14 50 55

FN 32-160NA 32 50 450 80 100 70 240 190 132 160 14 50 65

FN 32-200N 32 50 426 80 100 70 240 190 160 180 14 50 46

FN 32-200NC 32 50 426 80 100 70 240 190 160 180 14 50 47

FN 32-200NB 32 50 450 80 100 70 240 190 160 180 14 50 52

FN 32-200NA 32 50 492 80 100 70 240 190 160 180 14 50 60

FN 32-250E 32 50 532 100 125 95 320 250 180 225 14 65 70

FN 32-250D 32 50 612 100 125 95 320 250 180 225 14 65 81

FN 32-250C 32 50 612 100 125 95 320 250 180 225 14 65 90

FN 32-250B 32 50 612 100 125 95 320 250 180 225 14 65 95

FN 32-250A 32 50 744 100 125 95 320 250 180 225 14 65 100

DN a1 b1 c1 d1 e1

32 78 100 140 4 19

50 102 125 165 4 19

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1

n2b

101

Page 102: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

111

FN 40 Surface Horizontal

Hydraulic performance table

DN a1 b1 c1 d1 e1

40 88 110 150 4 19

65 122 145 185 4 19

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1n2

b

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN 40-125C 40 65 373 80 100 70 190 140 112 140 14 50 32

FN 40-125B 40 65 365 80 100 70 190 140 112 140 14 50 33

FN 40-125A 40 65 390 80 100 70 190 140 112 140 14 50 36

FN 40-160NC/B 40 65 400 80 100 70 240 190 132 160 14 50 39

FN 40-160NB/B 40 65 425 80 100 70 240 190 132 160 14 50 43

FN 40-160NC/A 40 65 425 80 100 70 240 190 132 160 14 50 42

FN 40-160NB/A 40 65 450 80 100 70 240 190 132 160 14 50 46

FN 40-160NA 40 65 450 80 100 70 240 190 132 160 14 50 51

FN 40-200C 40 65 425 100 100 70 265 212 160 180 14 50 50

FN 40-200B 40 65 450 100 100 70 265 212 160 180 14 50 55

FN 40-200A 40 65 490 100 100 70 265 212 160 180 14 50 62

FN 40-200NB 40 65 490 100 100 70 265 212 160 180 14 50 61

FN 40-200NA 40 65 571 100 100 70 265 212 160 180 14 50 79

FN 40-250C 40 65 612 100 125 95 320 250 180 225 14 65 90

FN 40-250B 40 65 612 100 125 95 320 250 180 225 14 65 91

FN 40-250A 40 65 612 100 125 95 320 250 180 225 14 65 96

FN 40-250NE 40 65 612 100 125 95 320 250 180 225 14 65 92

FN 40-250ND 40 65 612 100 125 95 320 250 180 225 14 65 90

FN 40-250NC 40 65 644 100 125 95 320 250 180 225 14 65 98

FN 40-250NB 40 65 644 100 125 95 320 250 180 225 14 65 137

FN 40-250NA 40 65 644 100 125 95 320 250 180 225 14 65 141

ModelP2 l/min 0 133 167 200 233 267 300 333 417 500 583 667 750 833 917 1000

[kW] [HP] m3/h 0 8 10 12 14 16 18 20 25 30 35 40 45 50 55 60

FN 40-125C 1.5 2m

wc

18.5 18.5 18.3 18.1 17.8 17.5 16.9 16.2 14.8 12.5 9.4

FN 40-125B 2.2 3 22 22 22 21.8 21.5 21.2 20.8 19.4 17.5 14.9

FN 40-125A 3 4 27.5 27.5 27.3 27.1 26.8 26.4 26 24.5 23 19.8 17.2

FN 40-160NC/B 3 4 32 31.7 31.6 31.4 31 30.7 30.2 28.8 26.7

FN 40-160NC/A 4 5.5 36.7 36.6 36.5 36.3 36 35.5 34 32 30.1

FN 40-160NB/B 4 5.5 32 31.6 31.4 31 30.7 30.2 28.8 26.7 23 21 16

FN 40-160NB/A 5.5 7.5 36.7 36.6 36.5 36.3 36 35.5 34 32 30.1 27.4 24.5 20.5

FN 40-160NA 5.5 7.5 39 39 39 38.9 38.8 38.7 37.4 36 33.8 31.8 28.7 25.4 22

FN 40-200C 4 5.5 45 43.9 43.7 43.5 42.2 41.2 37.3 33.5

FN 40-200B 5.5 7.5 48.8 48.3 48 47.5 46.8 46 43.6 40.4 36.5 31.4

FN 40-200A 7.5 10 58.2 58 57.9 57.9 57.6 57 55 52 48 42

FN 40-200NB 7.5 10 53 52.5 51.4 49.4 47 44.2 41.5 37.5 30.5

FN 40-200NA 11 15 61 60 59 57 56 54 50 47 41.5 35

FN 40-250C 9.2 12.5 63 61 60.6 60.3 59.1 58 54.5 50 49 45

FN 40-250B 11 15 70.6 68.1 67.2 66.4 65.5 64.5 62.5 59.5 56.5 53

FN 40-250A 15 20 88 87.6 86.9 86.3 85.7 85 82.9 79 75 71

FN 40-250NE 12.5 17 67.5 66.7 66.4 65.9 65.4 64.8 64 62.3 60.3 58.3 54.3 48.9 45.3 43

FN 40-250ND 15 20 74 73 72.8 72.5 72.3 72 71 70 68 66 64 62 60 57 54

FN 40-250NC 17 23 82 81 80.8 80.5 80.2 80 79 78 76.5 75 73 70.5 68 65 62

FN 40-250NB 18.5 25 89 88.5 88.3 87.9 87.6 87.3 86 85.5 84 82.1 80 77.5 74.6 71.4 68

FN 40-250NA 22 30 98 95.8 95.6 95.4 95 94.5 93.2 91.6 89.7 87.8 85.2 83.9 79 75.8 71.3

102

Page 103: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

112

FN 50 Surface Horizontal

Hydraulic performance table

ModelP2 l/min 0 300 417 500 667 750 833 917 1000 1167 1250 1417 1500 1667 1833 2000

[kW] [HP] m3/h 0 18 25 30 40 45 50 55 60 70 75 85 90 100 110 120

FN 50-125C 2.2 3

mw

c

17.5 17.2 16.7 16 14.3 13.2 12 10 8

FN 50-125B 3 4 21.2 20 19.4 17.6 16.6 15.3 13.9 13

FN 50-125A 4 5.5 24.2 24.4 23.9 22.4 21.4 20.3 19.1 17.7

FN 50-160B 5.5 7.5 32.5 32 31.1 28.8 27.5 25.9 24.2 22.3 18.4 16.6

FN 50-160A 7.5 10 40.4 40 39.4 37.7 36.6 35.3 33.7 31.9 27.7 25.7

FN 50-160NC 5.5 7.5 30.5 27.7 27 26 24.9 23.6 20.6 20

FN 50-160NB 7.5 10 39 36.8 35.8 35 33.7 32.3 29 27

FN 50-160NA 9.2 12.5 44 40.6 40 39 38 36 34 32 28 26

FN 50-200C 9.2 12.5 52.2 52.1 49.6 47.8 45.9 43.4 41 35 32.3

FN 50-200B 11 15 58 57.3 54.3 52.3 50.1 47.2 44.2 37.3 33.8

FN 50-200A 15 20 61.8 60 58 56.5 55 53 50.5 45 41

FN 50-200NC 15 20 53.3 49.2 48 46.5 44.5 43 38 36.5 30.5

FN 50-200NB 17 23 61.5 56.4 55 53 50 48 45 42 37

FN 50-200NA 22 30 71 66.8 66 65 62 60 55 52.5 45.5 38 31.5

FN 50-250ND 17 23 69 68.5 67 64 62.5 61 58 56 47.3 44.2

FN 50-250NC/B 18.5 25 80 79 78.5 76 74.5 72 70 68 61.5

FN 50-250NC/A 20 27 80 79 78.5 76 74.5 72 70 68 61.5 58 50

FN 50-250NB/B 22 30 88.5 88 87 85 84 82 80 77 71 68

FN 50-250NB/A 25 34 88.5 88 87 85 84 82 80 77 71 68 60 57 44

FN 50-250NA 30 40 100.5 100 99.5 98 97 94.5 93 90.5 84 80 70 65 54

Dimensions and weights

Model DNm DNa Fig. f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN 50-125C 50 65 1 366 100 100 70 240 190 132 160 14 50 40

FN 50-125B 50 65 1 400 100 100 70 240 190 132 160 14 50 42

FN 50-125A 50 65 1 426 100 100 70 240 190 132 160 14 50 45

FN 50-160B 50 65 1 450 100 100 70 265 212 160 180 14 50 54

FN 50-160A 50 65 2 490 100 100 70 265 212 160 180 14 50 62

FN 50-160NC 50 65 2 450 100 100 70 265 212 160 180 14 50 54

FN 50-160NB 50 65 2 490 100 100 70 265 212 160 180 14 50 62

FN 50-160NA 50 65 2 530 100 100 70 265 212 160 180 14 50 74

FN 50-200C 50 65 2 576 100 100 70 265 212 160 200 14 50 80

FN 50-200B 50 65 2 576 100 100 70 265 212 160 200 14 50 85

FN 50-200A 50 65 2 576 100 100 70 265 212 160 200 14 50 90

FN 50-200NC 50 65 2 576 100 100 70 265 212 160 200 14 50 89

FN 50-200NB 50 65 2 644 100 100 70 265 212 160 200 14 50 92

FN 50-200NA 50 65 2 644 100 100 70 265 212 160 200 14 50 136

FN 50-250ND 50 65 2 644 100 125 95 320 250 180 225 14 65 136

FN 50-250NC/B 50 65 2 644 100 125 95 320 250 180 225 14 65 136

FN 50-250NC/A 50 65 2 644 100 125 95 320 250 180 225 14 65 138

FN 50-250NB/B 50 65 2 644 100 125 95 320 250 180 225 14 65 140

FN 50-250NB/A 50 65 2 714 100 125 95 320 250 180 225 14 65 250

FN 50-250NA 50 65 2 714 100 125 95 320 250 180 225 14 65 250

a

f

DNm

DNa

m1

m2

Fig. 1

h2

h1

s

n1

n2

b

DN a1 b1 c1 d1 e1

50 102 125 165 4 19

65 122 145 185 4 19

n°d1 holes ø e1

DN a1

b1

c1

Fig. 2

af

DNm

DNa

m1

m2

h2

h1

s

n1

n2

b

103

Page 104: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

113

FN 65 Surface Horizontal

Hydraulic performance table

ModelP2 l/min 0 500 667 833 917 1167 1250 1333 1500 1667 1833 2000 2167 2333 2667 2833

[kW] [HP] m3/h 0 30 40 50 55 70 75 80 90 100 110 120 130 140 160 170

FN 65-125D 3 4m

wc

12.5 12 11.9 11.6 11.4 9.5 8 7.4

FN 65-125C 4 5.5 17 16 15.6 15.4 15.2 14.2 13.5 13 11 8

FN 65-125B 5.5 7.5 21.5 21 20.9 20.8 20.7 19.9 19 18.1 16.4 14

FN 65-125A 7.5 10 26.5 26 25.9 25.8 25.7 25 24.5 24 22 19.4 17

FN 65-160C 9.2 12.5 32.8 32.3 31.6 30.8 30.6 28.7 27.8 27.1 25.2 23.1 20.3

FN 65-160B 11 15 38.8 38.3 37.8 37.3 37 35.7 35.3 34.5 32 30 27.8

FN 65-160A 15 20 43 43 42.7 42.3 41.9 40.8 40.4 39.7 38.2 36.2 33.5 30 28

FN 65-200C 15 20 43 42 41.6 39.8 39 38 35.9 33 31 27 23

FN 65-200B 18.5 25 48 47.9 47.3 46.2 45.8 45 42.8 40 36.9 33 30 25

FN 65-200A 22 30 55 55.1 55 54 53.5 53 51.5 49.5 47 44.2 41 35

FN 65-200NC 18.5 25 44.3 46.2 45.4 45 42.1 41.1 39.9 37.8 35.3 32.4 29.5 25.8 21.4

FN 65-200NB 22 30 50.7 53.6 53.6 53 51.6 50.8 50 48.3 46.4 44.3 41.7 38.5 35.3 27.5

FN 65-200NA 30 40 64 66.5 66 65.7 64.7 64.1 63.7 62 60 58 55.6 53 50 43 38

FN 65-250NC 22 30 68.2 68.8 68.5 67 66.3 65.3 63.8 62.8

FN 65-250NB 30 40 76 75 74.7 73.5 73 72.5 72 69 67 63.5

FN 65-250NA 37 50 89 89.5 89.2 88 87 86.5 85 84 82 79.5 76

Dimensions and weights

Model DNm DNa Fig. f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN 65-125D 65 80 1 400 100 125 95 280 212 160 180 14 65 42

FN 65-125C 65 80 1 426 100 125 95 280 212 160 180 14 65 48

FN 65-125B 65 80 1 450 100 125 95 280 212 160 180 14 65 55

FN 65-125A 65 80 2 500 100 125 95 280 212 160 180 14 65 60

FN 65-160C 65 80 2 534 100 125 95 280 212 160 200 14 65 80

FN 65-160B 65 80 2 534 100 125 95 280 212 160 200 14 65 82

FN 65-160A 65 80 2 534 100 125 95 280 212 160 200 14 65 88

FN 65-200C 65 80 2 576 100 125 95 320 250 180 225 14 65 93

FN 65-200B 65 80 2 644 100 125 95 320 250 180 225 14 65 135

FN 65-200A 65 80 2 644 100 125 95 320 250 180 225 14 65 141

FN 65-200NC 65 80 2 644 100 125 95 320 250 180 225 14 65 245

FN 65-200NB 65 80 2 644 100 125 95 320 250 180 225 14 65 250

FN 65-200NA 65 80 2 720 100 125 95 320 250 180 225 14 65 270

FN 65-250NC 65 80 2 680 100 160 120 360 280 200 250 18 80 260

FN 65-250NB 65 80 2 750 100 160 120 360 280 200 250 18 80 274

FN 65-250NA 65 80 2 750 100 160 120 360 280 200 250 18 80 285

a

f

DNm

DNa

m1

m2

Fig. 1

h2

h1

s

n1

n2

b

DN a1 b1 c1 d1 e1

65 122 145 185 4 19

80 138 160 200 4 19

n°d1 holes ø e1

DN a1

b1

c1

Fig. 2

af

DNm

DNa

m1

m2

h2

h1

s

n1

n2

b

104

Page 105: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

114

FN 80 Surface Horizontal

Hydraulic performance table

ModelP2 l/min 0 1083 1250 1500 1667 1833 2000 2333 2500 2750 3000 3250 3500 3750 4167 4583

[kW] [HP] m3/h 0 65 75 90 100 110 120 140 150 165 180 195 210 225 250 275

FN 80-160G 5.5 7.5

mw

c

17.8 17.3 16 15 14 13.1 12 10

FN 80-160F 7.5 10 20.2 19.9 19 18 17 16 15 13.7 11.7 10.5

FN 80-160E 9.2 12.5 25.3 25.3 24.8 24.2 23 22 21 19.1 18.1 16

FN 80-160D 11 15 26.5 26.5 26.1 25.4 24.5 23.8 23 20.8 19.6 17.6 14.8

FN 80-160C 15 20 30.5 30.5 30 28.5 27.5 26.5 24 22.4 20 18.5 17

FN 80-160B 18.5 25 37 35.8 34.5 33.6 32.6 31.8 29.5 28.4 26.4 24.1 21

FN 80-160A 22 30 40.3 40 39.4 39 38.2 37.5 35.9 34.7 32.8 30.5 28.8 25.5 23.5

FN 80-200B 30 40 50 52 51.3 50.5 50.4 47.9 46.5 45 44 41 39 37 31

FN 80-200A 37 50 56 58.4 58 57.5 57 55.3 54.6 53.4 51.3 49.2 46.7 44 39 35

Dimensions and weights

Model DNm DNa Fig. f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN 80-160G 80 100 2 455 125 125 95 320 250 180 225 14 65 64

FN 80-160F 80 100 2 496 125 125 95 320 250 180 225 14 65 75

FN 80-160E 80 100 2 576 125 125 95 320 250 180 225 14 65 84

FN 80-160D 80 100 2 576 125 125 95 320 250 180 225 14 65 90

FN 80-160C 80 100 2 576 125 125 95 320 250 180 225 14 65 95

FN 80-160B 80 100 2 644 125 125 95 320 250 180 225 14 65 137

FN 80-160A 80 100 2 644 125 125 95 320 250 180 225 14 65 139

FN 80-200B 80 100 2 750 125 125 95 345 280 180 250 14 65 274

FN 80-200A 80 100 2 750 125 125 95 345 280 180 250 14 65 280

a

f

DNm

DNa

m1

m2

Fig. 1

h2

h1

s

n1

n2

b

DN a1 b1 c1 d1 e1

80 138 160 200 8 19

100 158 180 220 8 19

125 188 210 250 8 19

n°d1 holes ø e1

DN a1

b1

c1

Fig. 2

af

DNm

DNa

m1

m2

h2

h1

s

n1

n2

b

105

Page 106: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

115

FN100/125 Surface Horizontal

Hydraulic performance table

ModelP2 l/min 0 1000 1250 1500 1750 2000 2250 2500 2750 3000 3500 4000 4500 5000

[kW] [HP] m3/h 0 60 75 90 105 120 135 150 165 180 210 240 270 300

FN 100x80x160D 11 15m

wc

25 24 23 22 21 19.5 18 16.5 15

FN 100x80x160C 15 20 29 28.5 28 27 26 24.5 23 21.5 20 18.5

FN 100x80x160B 15 20 35 34 33.3 32.5 31.8 31 29 27.5 26 24.5

FN 100x80x200D 18.5 25 42 42 41 40 38.5 37 35 33 30.5 28

FN 100x80x200C 22 30 47 47 46.5 45.5 44.5 43 41 39 37 34

FN 100x80x200B 30 40 55 55 54 53 52 51 49 47 45 43 37

FN 100x80x200A 37 50 57.5 57 56.8 56.5 56 55 54 52.5 51 48 42

FN 100x80x250D 37 50 68 68 67 66 65 63 61 58 55 47

FN 125x100x200D 22 30 40 39 38 37 36 34.5 33 31.5 28 24

FN 125x100x200C 30 40 48 47 46.5 46 45 44 42.5 41 38 34.5 30

FN 125x100x200B 37 50 54 54 53.5 53 52 51 50 49 46 43 38 34

Dimensions and weights

Model DNm DNa Fig. f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN 100x80x160D 80 100 1 540 125 125 95 320 250 180 225 14 65 74

FN 100x80x160C 80 100 1 540 125 125 95 320 250 180 225 14 65 81.5

FN 100x80x160B 80 100 1 540 125 125 95 320 250 180 225 14 65 88.5

FN 100x80x200D 80 100 2 710 125 298 241 320 280 180 250 14 55 132

FN 100x80x200C 80 100 2 710 125 298 241 320 280 180 250 14 55 150

FN 100x80x200B 80 100 2 805 125 345 305 360 318 200 250 18 60 192

FN 100x80x200A 80 100 2 805 125 345 305 360 318 200 250 18 60 210

FN 100x80x250D 80 100 2 805 125 345 305 360 318 200 280 18 60 196

FN 125x100x200D 125 100 2 710 125 298 241 320 318 180 280 14 55 160

FN 125x100x200C 125 100 2 805 125 345 305 360 318 200 280 18 60 202

FN 125x100x200B 125 100 2 805 125 345 305 360 318 200 280 18 60 220

a

f

DNm

DNa

m1

m2

Fig. 1

h2

h1

s

n1

n2

b

DN a1 b1 c1 d1 e1

80 138 160 200 8 19

100 158 180 220 8 19

125 188 210 250 8 19

n°d1 holes ø e1

DN a1

b1

c1

Fig. 2

af

DNm

DNa

m1

m2

h2

h1

s

n1

n2

b

106

Page 107: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

116

FN4 32/40 Surface Horizontal

Hydraulic performance table

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN4 32-125A 32 50 333 80 100 70 190 140 112 140 14 50 23

FN4 32-160A 32 50 336 80 100 70 240 190 132 160 14 50 31

FN4 32-200NA 32 50 370 80 100 70 240 190 160 180 14 50 42

FN4 32-250C 32 50 400 100 125 95 320 250 180 225 14 65 53

FN4 32-250A 32 50 400 100 125 95 320 250 180 225 14 65 55

FN4 40-125A 40 65 333 80 100 70 210 160 112 140 14 50 34

FN4 40-160NA 40 65 336 80 100 70 240 190 132 160 14 50 34

FN4 40-200A 40 65 371 100 100 70 265 212 160 180 14 50 43

FN4 40-250NC 40 65 400 100 125 95 320 250 180 225 14 65 55

FN4 40-250NA 40 65 431 100 125 95 320 250 180 225 14 65 58.5

FN4 40-315C 40 65 478 100 125 95 345 280 225 250 14 65 94

FN4 40-315B 40 65 566 100 125 95 345 280 225 250 14 65 114

FN4 40-315A 40 65 646 100 125 95 345 280 225 250 14 65 119

DN a1 b1 c1 d1 e1

32 78 100 140 4 19

50 102 125 165 4 19

40 88 110 150 4 19

65 122 145 185 4 19

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1

n2b

ModelP2 l/min 0 50 67 100 133 167 200 233 267 300 333 417

[kW] [HP] m3/h 0 3 4 6 8 10 12 14 16 18 20 25

FN4 32-125A 0.37 0.5

mw

c

6.1 6 5.9 5.5 5 4 3.5

FN4 32-160A 0.55 0.75 9.5 9.4 9.3 8.9 8.1 7.1 5.8 5

FN4 32-200NA 1.1 1.5 16.5 16.2 16 15.9 15.2 14 12.7 11.2 9.5 7.5

FN4 32-250C 2.2 3 20 19.5 19.3 19 18.6 18.4 18 17.6 17.2 16.6 16.2 15

FN4 32-250A 3 4 23.5 23.1 23 22.6 22.2 21.8 21.3 20.8 20.1 19.4 18.5 15.8

FN4 32

ModelP2 l/min 0 100 133 167 200 233 300 333 417 500 583 667 750 883 917 1000

[kW] [HP] m3/h 0 6 8 10 12 14 18 20 25 30 35 40 45 50 55 60

FN4 40-125A 0.37 0.5

mw

c

6.2 6.1 6 5.8 5.5 5.1 4.2 3.5

FN4 40-160NA 0.75 1 9.8 9.7 9.6 9.5 9.2 8.9 8.2 7.6 6.7 5

FN4 40-200A 1.1 1.5 14 13.6 13.3 12.9 12.4 11.7 10.1 9.2 6.7

FN4 40-250NC 2.2 3 20 19.9 19.6 19.4 19.2 19 18.3 17.8 16.6 15 12.6

FN4 40-250NA 3 4 23.7 23.6 23.5 23.3 23.1 22.8 22.2 21.7 20.3 18.5 16.2

FN4 40-315C 4 5.5 25.2 25.1 25 24.9 24.8 24.7 24.4 24.2 23.4 22.5 21.1 19.5

FN4 40-315B 5.5 7.5 30.9 30.7 30.6 30.6 30.5 30.4 30 29.8 29.1 27.9 26.7 25.5 23.5 21.1

FN4 40-315A 9.2 12.5 40 40 40 39.9 39.6 39.5 39 38.4 37.6 36.7 35.6 34 32.6 30.8

FN4 40

107

Page 108: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

117

DN a1 b1 c1 d1 e1

50 102 125 165 4 19

65 122 145 185 4 19

80 138 160 185 8 19

FN4 50/65 Surface Horizontal

Hydraulic performance table

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1

n2b

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN4 50-125A 50 65 333 100 100 70 240 190 132 160 14 50 32

FN4 50-160A 50 65 371 100 100 70 265 212 160 180 14 50 42

FN4 50-200A 50 65 405 100 100 70 265 212 160 200 14 50 46

FN4 50-200NA 50 65 436 100 100 70 265 212 160 200 14 50 57

FN4 50-250ND 50 65 400 100 125 95 320 250 180 225 14 65 59

FN4 50-250NA 50 65 450 100 125 95 320 250 180 225 14 65 68.5

FN4 65-125A 65 80 373 100 125 95 280 212 160 180 14 65 35

FN4 65-160A 65 80 376 100 125 95 280 212 160 200 14 65 43.5

FN4 65-200A 65 80 436 100 125 95 280 250 180 225 14 65 60.5

FN4 65-200NA 65 80 436 100 125 95 280 250 180 225 14 65 64

FN4 65-250NB 65 80 482 100 160 120 360 280 200 250 18 80 81

FN4 65-250NA 65 80 602 100 160 120 360 280 200 250 18 80 86

FN4 65-315C 65 80 646 125 160 120 400 315 225 280 18 80 177

FN4 65-315B 65 80 709 125 160 120 400 315 225 280 18 80 196

FN4 65-315A 65 80 750 125 160 120 400 315 225 280 18 80 225

ModelP2 l/min 0 417 500 667 750 833 917 1000 1250 1333 1500 1667 1833 2000 2167 2333

[kW] [HP] m3/h 0 25 30 40 45 50 55 60 75 80 90 100 110 120 130 140

FN4 65-125A 0.75 1

mw

c

6.1 5.6 5.4 4.7 4.2 3.7 3.1

FN4 65-160A 1.5 2 10.4 10.3 10.1 9.5 9.1 8.7 8.2 7.6

FN4 65-200A 3 4 13.5 13.4 13 12.2 11.7 11.1 10.4 9.6 6.12 4

FN4 65-200NA 3 4 17.7 17.3 16.9 16 15.5 15 14.2 13.4 10.5 9.3

FN4 65-250NB 4 5.5 19 18.7 18.6 18.2 18 17.5 16.9 15.7

FN4 65-250NA 5.5 7.5 22.2 22 21.8 21.4 21.1 20.5 20.1 19.5 16.8 15.6 13

FN4 65-315C 9.2 12.5 28.5 28.3 28.2 27.7 27.3 27 26.4 25.7 23.5 23 21.2 19 16.2 14

FN4 65-315B 11 15 33 32.6 32.2 32 31.7 31.4 31 30 29 27 24.3 21.3 18.8

FN4 65-315A 15 20 43 42 41 40.5 40.2 40 39.2 37.2 36.5 35 33.2 31 28.8 26.3 23.7

FN4 65

ModelP2 l/min 0 167 200 233 300 333 417 500 583 667 750 883 917 1000

[kW] [HP] m3/h 0 10 12 14 18 20 25 30 35 40 45 50 55 60

FN4 50-125A 0.55 0.75m

wc

6.4 6.3 6.2 6.1 5.8 5.6 5.1 4.2

FN4 50-160A 1.1 1.5 9 8.9 8.8 8.7 8.5 8.2 7.7 6.7 5.7

FN4 50-200A 1.5 2 14 13.7 13.5 13.3 12.7 12.4 11.3 10 8.2

FN4 50-200NA 3 4 18 18 17.9 17.8 17.5 17 16.8 16 14.8 13.8 12.2 10.8 9.2

FN4 50-250ND 2.2 3 16.8 16.5 16.3 16.1 15.8 15.4 14.8 13.7 12.5 10

FN4 50-250NA 4 5.5 24 23.8 23.7 23.6 23.4 23.3 22.9 22.1 21.2 20 18 16.4 13.9 11.3

FN4 50

108

Page 109: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

118

DN a1 b1 c1 d1 e1

80 138 160 185 8 19

100 158 180 220 8 19

125 188 210 250 8 19

FN4 80/100 Surface Horizontal

Hydraulic performance table

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1

n2b

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN4 80-160C 80 100 405 125 125 95 320 250 180 225 14 65 56

FN4 80-160A 80 100 405 125 125 95 320 250 180 225 14 65 60

FN4 80-200B 80 100 485 125 125 95 345 280 180 250 14 65 74.5

FN4 80-200A 80 100 564 125 125 95 345 280 180 250 14 65 95

FN4 80-250C 80 100 647 125 160 120 400 315 200 280 18 80 115

FN4 80-250A 80 100 647 125 160 120 400 315 200 280 18 80 116

FN4 80-315C 80 100 709 125 160 120 400 315 250 315 18 80 262

FN4 80-315B 80 100 750 125 160 120 400 315 250 315 18 80 293

FN4 80-315A 80 100 775 125 160 120 400 315 250 315 18 80 321

FN4 100-200C 125 100 604 125 160 120 360 275 200 280 18 80 133

FN4 100-200A 125 100 646 125 160 120 360 275 200 280 18 80 136

FN4 100-250B 125 100 646 140 160 120 400 315 225 280 18 80 179

FN4 100-250A 125 100 750 140 160 120 400 315 225 280 18 80 210

FN4 100-315C 125 100 775 140 160 120 400 315 250 315 18 80 337

FN4 100-315B 125 100 775 140 160 120 400 315 250 315 18 80 349

ModelP2 l/min 0 667 833 1000 1167 1333 1500 1667 2000 2167 2333 2500 2667 3000 3333 3833

[kW] [HP] m3/h 0 40 50 60 70 80 90 100 120 130 140 150 160 180 200 230

FN4 80-160C 2.2 3

mw

c

8.2 7.8 7.4 7 6.3 5.6 5 4.5

FN4 80-160A 2.2 3 9.6 9.4 9.2 8.8 8.2 7.6 6.8 6 4.5

FN4 80-200B 4 5.5 13 12.8 12.6 12.4 12 11.5 10.9 10.1 8.1 7

FN4 80-200A 5.5 7.5 14.5 14.5 14.5 14.3 14.1 13.8 13.3 12.8 11.1 10 8.7 7.3

FN4 80-250C 7.5 10 18 17.8 17.5 17 16.5 16 15.6 15.4 13 12.3 10.8 9.7 8.4

FN4 80-250A 9.2 12.5 24.2 23.6 23.3 23 22.6 22.1 21.6 21.1 19.7 18.9 17.9

FN4 80-315C 11 15 28.1 28.1 28.1 27.9 27.3 26.9 26.4 25.5 23.8 23 22 21.3

FN4 80-315B 15 20 34 34 34 33.8 33.5 33 32.5 32.2 30.5 29.5 28.6 27.6 26.3

FN4 80-315A 22 30 40.7 40.3 40 39.6 39.1 38.6 37.5 36.5 35.8 34.6 33.7 31 28.5 24

FN4 80

ModelP2 l/min 0 1000 1167 1333 1500 1833 2000 2167 2333 2500 2667 2833 3000 3333 3750 4167

[kW] [HP] m3/h 0 60 70 80 90 110 120 130 140 150 160 170 180 200 225 250

FN4 100-200C 2.2 3

mw

c

10.5 10.4 10.1 9.8 9.4 8.4 7.9 7.1 6.5 5.6

FN4 100-200A 2.2 3 15 15 14.9 14.6 14.3 13.5 13.1 12.5 11.8 11.1 10.4 9.5 8

FN4 100-250B 4 5.5 20.9 20.9 20.7 20.4 20.2 19.5 19 18.5 17.5 17 16.5 15 12.4 10 7

FN4 100-250A 5.5 7.5 24.7 24.7 24.7 24.4 24 23.5 23.3 22.6 22.2 21.4 20.6 20 18.2 15.9 13.4 10

FN4 100-315C 7.5 10 28 28 27.8 27.6 27.5 26.7 26.2 25.8 25.4 24.8 24.4 23.6 22.3 20.2 18

FN4 100-315B 9.2 12.5 33.7 33.5 33.5 33.3 32.9 32.5 32.5 32.1 31.8 31.5 30.5 28.8 27.6 25.6

FN4 100

109

Page 110: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

119

FN4 125/150 Surface Horizontal

Hydraulic performance table

DN a1 b1 c1 d1 e1

100 158 180 220 8 19

125 188 210 250 8 19

150 212 240 285 8 22

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1

n2b

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN4 125x100x200Y 100 125 435 125 160 120 360 280 200 280 18 80 78

FN4 125x100x200X 100 125 540 125 160 120 360 280 200 280 18 80 90

FN4 125x100x250Y 100 125 535 140 160 120 400 315 225 280 18 80 112

FN4 125x100x250X 100 125 535 140 160 120 400 315 225 280 18 80 118

FN4 150x125x200W 150 125 560 140 160 120 400 315 250 315 18 80 124

FN4 150x125x200Z 150 125 560 140 160 120 400 315 250 315 18 80 134

FN4 150x125x200Y 150 125 560 140 160 120 400 315 250 315 18 80 134

FN4 150x125x200X 150 125 560 140 160 120 400 315 250 315 18 80 140

FN4 150x125x250Z 150 125 560 140 160 120 400 315 250 355 18 80 162

FN4 150x125x250Y 150 125 715 140 160 120 400 315 250 355 18 80 190

FN4 150x125x250X 150 125 715 140 160 120 400 315 250 355 18 80 190

FN4 125

ModelP2 l/min 0 900 1000 1100 1200 1300 1400 1500 1750 2000 2250 2500 2750 3000

[kW] [HP] m3/h 0 18 21 24 27 30 33 36 39 42 48 54 60 66

FNA 125x100x200Y 4 5.5

mw

c

13 12.4 12.2 12 11.8 11.6 11.4 11.2 10.3 9.3 8.2 6.8 4.8

FNA 125x100x200X 5.5 7.5 14.8 14.5 14.4 14.2 14 13,8 13.6 13.4 12.8 12 11 10 8.5

FNA 125x100x250Y 7.5 10 20 19.5 19.3 19.1 18.9 18.7 18.5 17.5 16.5 15.2 14 12

FNA 125x100x250X 11 15 22.5 22 21.9 21.8 21.7 21.6 21.3 20.5 19.6 18.5 17 15 13

FN4 150

ModelP2 l/min 0 1800 2000 2500 3000 3500 4000 4500 5000

[kW] [HP] m3/h 0 108 120 150 180 210 240 270 300

FNA 150x125x200W 5.5 7.5

mw

c

11 10.4 10.2 9.4 8.3 6.8

FNA 150x125x200Z 7.5 10 12.5 11.6 11.5 10.9 9.9 8.6 7

FNA 150x125x200Y 7.5 10 13.5 13 12.8 12.3 11.6 10.5 9.1 7.5

FNA 150x125x200X 11 15 15 14.3 14.2 13.8 13.2 12.3 11.1 9.6 8

FNA 150x125x250Z 11 15 17.5 17 16.6 15.7 14.4 12.6

FNA 150x125x250Y 15 20 21.2 19.8 19 18 16.6 15

FNA 150x125x250X 15 20 22 20.8 19.7 18.6 17 15.2 13.2

110

Page 111: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

120

FN4 200/250 Surface Horizontal

Hydraulic performance table

DN a1 b1 c1 d1 e1

100 158 180 220 8 19

125 188 210 250 8 19

150 212 240 285 8 22

a f

DNm

DNa

m1

m2

h2

h1

s

n°d1 holes ø e1

n1

DN a1

b1

c1

n2b

Dimensions and weights

Model DNm DNa f a m1 m2 n1 n2 h1 h2 s b [Kg]

FN4 200x150x200W 200 150 695 160 200 155 550 450 280 400 24 100 167

FN4 200x150x200Z 200 150 695 160 200 155 550 450 280 400 24 100 173

FN4 200x150x200Y 200 150 695 160 200 155 550 450 280 400 24 100 175

FN4 200x150x200X 200 150 715 160 200 155 550 450 280 400 24 100 203

FN4 250x200x250W 250 200 800 200 200 155 550 450 315 450 24 100 278

FN4 250x200x250Z 250 200 800 200 200 155 550 450 315 450 24 100 278

FN4 250x200x250Y 250 200 800 200 200 155 550 450 315 450 24 100 300

FN4 250x200x250X 250 200 800 200 200 155 550 450 315 450 24 100 300

FN4 200

FN4 250

ModelP2 l/min 0 4500 5000 5500 6000 6500 7000 8000 9000 10000

[kW] [HP] m3/h 0 270 300 330 360 390 420 480 540 600

FNA 250x200x250W 18.5 25

mw

c

16 13.5 13 12.4 11.8 11.2 10.5 9

FNA 250x200x250Z 18.5 25 17 14.6 14 13.5 13 12.4 11.7 10.2

FNA 250x200x250Y 22 30 19 17 16.5 16 15.4 14.7 14 12.4 10.5

FNA 250x200x250X 22 30 20.2 18.4 18 17.6 17 16.4 15.8 14.3 12.5 10.6

ModelP2 l/min 0 2500 3000 3500 4000 4500 5000 5500 6000 6500

[kW] [HP] m3/h 0 150 180 210 240 270 300 330 360 390

FNA 200x150x200W 7.5 10m

wc

11.5 10.4 9.7 8.9 7.9 6.7 5.5

FNA 200x150x200Z 11 15 18.5 11.5 10.9 10.2 9.3 8.3 7 5.8

FNA 200x150x200Y 11 15 14.2 13.3 12.6 12 11.1 10.1 9 7.6

FNA 200x150x200X 15 20 16 14.5 14 13.2 12.5 11.6 10.6 9.4 8

111

Page 112: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

121

Applications

Recycling plants, heating, air conditioning,

heat recovery, plants of water supply

procurement, pressure boosting and

fire fighting systems.

Materials

Pump body in cast iron.

Impeller in cast iron (option for bronze or

stainless steel).

Seal holding cover in cast iron (option

for bronze or stainless steel).

Shaft in stainless steel.

Energy Index MEI 0.1 to 0.4

Description

The FNS pump is a monoblock centrifugal

pump with standardised dimensions in

accordance with the EN733 standard.

Options

Different mechanical seals.

Frequency 60 Hz.

Counter flange kits.

FNS Surface Horizontal

Cast iron close coupled end suction pumps with shaft coupling

Motor

IP 55 protection.

Class F insulation.

IE2 efficiency.

Standard tensions: 220-240 V up to

4 kW, 380-415 V/660-720 V starting

from 5.5 kW.

Frequency: 50 Hz.

imitations

Liquid temperature range -15 to +120 °C.

Ambient temperature max 40 °C.

Water mixed with glycol, parameters

must be checked with over 20% of

glycol. Pure non-explosive liquid media

free from mineral oils and without solids.

Field of application at 2900 rpm

Curves obtained in accordance with ISO9906, appendix A

200

10090

80

70

60

50

40

32.8

H

[ft]

H

[m]

60

50

40

30

20

10

90

80

70

H

[kPa]

600

500

400

300

200

100

900

800

700

lmp g.p.m 60 80 100 200 400 600 800 100040

U.S. g.p.m 60 80 100 200 400 600 800 1000

400020001000800600400200 Q [l/1’]

Q [m3/h]2001009080706050403020109876

112

Page 113: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

122

Applications

Recycling plants, heating, air conditioning,

heat recovery, plants of water supply

procurement, pressure boosting and

fire fighting systems.

Materials

Pump body in cast iron (option for bronze

FNFM or stainless steel FNFX).

Impeller in cast iron (option for bronze or

stainless steel).

Seal holding cover in cast iron (option

for bronze or stainless steel).

Shaft in stainless steel.

Energy Index MEI 0.1 to 0.4

Description

The FNF pump is a monoblock centrifugal

pump with standardised dimensions in

accordance with the EN733 standard.

FNF: Bareshaft end suction pump.

FNFZ: Bareshaft end suction pump with

electric motor on a base.

FNFT: Bareshaft end suction pump with

dimensions exceeding EN 733 standard.

FNF/FNFT Surface Horizontal

Cast iron long coupled end suction pumps with shaft coupling

Motor

IP 55 protection.

Class F insulation.

IE2 efficiency.

Standard tensions: 220-240 V up to

4 kW, 380-415 V/660-720 V starting

from 5.5 kW.

Frequency: 50 Hz.

Options

Different mechanical seals.

Frequency 60 Hz.

Limitations

Liquid temperature range -15 to +120 °C.

Ambient temperature max 40 °C.

Water mixed with glycol, parameters

must be checked with over 20% of

glycol. Pure non-explosive liquid media

free from mineral oils and without solids.

Field of application at 2900 rpm (NCB)

Curves obtained in accordance with ISO9906, appendix A

154

100

85

69

54

46

38

31

2319.68

231

H

[ft]H

[m]

80

70

60

50

40

30

20

10987

6

H

[kPa]

600

500

400

300

200

100908070

60

800

700

lmp g.p.m 40 60 80 100 200 400 600 8001000 2000

U.S. g.p.m 40 60 80 100 200 400 600 8001000 2000

8000600040002000100060040020010080 Q [l/1’]

Q [m3/h]3002001008060403020108654 400

113

Page 114: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

123

FNF/FNFT Surface Horizontal

Field of application at 1450 rpm (NCB)

Curves obtained in accordance with ISO9906, appendix A

100

80

60

50

40

30

20

10

70

H

[ft]

800060004000200010006004002001008060 Q [l/1’]

Q [m3/h]40020010080604020108643

H

[m]

40

30

20

10

8

6

5

4

3

H

[kPa]

400

300

200

100

80

60

50

40

30

lmp g.p.m 40 60 80 100 200 400 600 1000 2000

U.S. g.p.m 40 60 80 100 200 400 600 1000 2000

Field of application at 1450 rpm (NCBT)

Curves obtained in accordance with ISO9906, appendix A

200

150

100

50

32.8

H

[ft]

250002000015000100005000 Q [l/1’]

Q [m3/h]1600140012001000800600400200

lmp g.p.m 1000 2000 3000 4000 5000 6000 7000

U.S. g.p.m 2000 3000 4000 5000 6000 7000 8000

H

[m]

70

60

50

40

30

20

10

H

[kPa]

700

600

500

400

300

200

100

114

Page 115: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

124

Applications

These multistage electric pumps are used

in irrigation systems, systems with high

pressure lifting, refrigeration, heating,

snowing, cleaning, boiler systems and in

condensed extraction.

Description & features

Suction body with axial (TM) or radial

(TMB/TMV) inlet, intermediate.

Stage composed of stage body and

corresponding diffuser with wearing rings.

Replaceable impeller seats.

Delivery body with upward outlet.

With the possibility of turning in at

90° both directions.

Drive side bearing support with high rigidity.

TM/TMV: suction side support of

sliding type, lubricated by the pumped

liquid.

TMB: double support.

Shaft in stainless steel completely

protected.

Adjustable parking seal on the shaft or

not balanced/balanced mechanical seal

according to the working pressure.

Eternal tie rods for tightening of the

intermediate stages.

Options

Pump c/w motor IE2 efficency on base

plate.Special materials.

TM/TMB/TMV Surface Horizontal

High pressure multistage pumps

Materials

Impellers & diffusers in cast iron

EN-GJL-250 or carbon steel.

Suction, delivery and stage casing

in cast iron EN-GJL-250-GJS-500

or carbon steel.

Shaft and protection bushes in

stainless steel AISI 431.

Tie rods in carbon steel.

Energy Index MEI 0.1 to 0.4.

Perfomance tolerances

Pumps: UNI EN ISO 9906.

Appendix A, Level 1 on request.

Range

Q max = 1000 m3/h.

H max = 600 m.

Rotation: from 1450 to 3550 rpm.

From DN40 to DN200.

Limitations

Liquid temperature range -15 to +120 °C.

Ambient temperature max 40 °C.

Maximum working pressure 40 or 63 bar.

The pump liquid has to be

chemically and mechanically

suitable for the utilised materials.

Curves obtained in accordance with ISO9906, appendix A Curves obtained in accordance with ISO9906, appendix A

Field of application at 2900 rpm Field of application at 1450 rpm

115

Page 116: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

125

Applications

Recycling plants, heating, air conditioning,

heat recovery, plants of water supply

procurement, irrigation, fire fighting

systems and process plants.

Materials

Pump case, cover & supports in cast iron

EN-GJL-250.

Impeller in cast iron EN-GJL-250 or

stainless steel AISI 316 or

bronze G-CuSn 10.

Shaft in stainless steel AISI 431 or

stainless steel Duplex.

Shaft seal: Soft parking or mechanical

seal.

Description & features

Axial splits case pump with double

suction radial impeller.

Double volute design.

Low vibration.

No shaft flexion.

CFD hydraulic design.

High efficiency.

Low NPSH.

Horizontal or vertical.

The symmetrical construction allows the

drive to be positioned on either side of

the pump.

FSC Surface Horizontal

Cast iron split casing pumps

Perfomance tolerances

Pumps: UNI EN ISO 9906

Appendix A, Level 1 on request.

Range

Q max = 4500 m3/h.

H max = 180 m.

Rotation: from 750 to 3550 rpm.

From DN125 to DN500.

Working pressure up to PN25.

Options

Pump c/w motor IE2 efficiency on base

plate.

Special materials.

Grease or oil lubricated bearings.

Limitations

Liquid temperature range -15 to +120 °C

Density: 100 Kg/m3.

Liquid: Clear or slightly polluted water,

without abrasive or solids.

CFD Desing

Technical characteristics at 590, 730 and 980 rpm

ModelP

[kW]

Q

[m3/h]

H

[m]rpm

FSC 500-550 400 2500 ÷ 4800 36 ÷ 20 980

FSC 500-550 250 3000 ÷ 4900 18 ÷ 12 730

FSC 500-550 160 3000 ÷ 4900 12 ÷ 5 590

116

Page 117: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

126

FSC Surface Horizontal

Technical characteristics at 1450 rpm

ModelP

[kW]

Q

[m3/h]

H

[m]

FSC 125-250 15 150 ÷ 300 18 ÷ 12

FSC 125-335 37 150 ÷ 300 38 ÷ 26

FSC 125-375 45 150 ÷ 320 50 ÷ 38

FSC 125-425 75 150 ÷ 350 65 ÷ 44

FSC 150-295 30 250 ÷ 500 24 ÷ 16

FSC 150-395 75 300 ÷ 500 55 ÷ 40

FSC 150-440 110 300 ÷ 520 65 ÷ 50

FSC 150-500 160 300 ÷ 550 85 ÷ 65

FSC 200-345 75 450 ÷ 820 32 ÷ 22

FSC 200-465 160 400 ÷ 820 75 ÷ 55

FSC 200-520 250 400 ÷ 850 95 ÷ 75

FSC 200-590 315 400 ÷ 950 125 ÷ 90

FSC 250-410 160 700 ÷ 1400 45 ÷ 30

FSC 250-550 355 600 ÷ 1350 105 ÷ 75

FSC 250-615 500 800 ÷ 1400 130 ÷ 100

FSC 250-700 800 800 ÷ 1550 170 ÷ 130

FSC 300-485 315 1300 ÷ 2300 65 ÷ 45

FSC 300-650 800 1300 ÷ 2200 140 ÷ 100

FSC 300-730 1200 1300 ÷ 2300 180 ÷ 140

Technical characteristics at 1750 rpm

ModelP

[kW]

Q

[m3/h]

H

[m]

FSC 125-250 22 150 ÷ 370 26 ÷ 17

FSC 125-270 45 200 ÷ 420 36 ÷ 24

FSC 125-335 55 200 ÷ 350 58 ÷40

FSC 125-375 90 200 ÷ 370 70 ÷ 55

FSC 125-425 132 200 ÷ 420 90 ÷ 68

FSC 150-295 55 250 ÷ 600 36 ÷ 24

FSC 150-320 90 300 ÷ 700 50 ÷ 32

FSC 150-395 132 300 ÷ 600 78 ÷ 57

FSC 150-440 200 300 ÷ 600 100 ÷ 80

FSC 150-500 250 300 ÷ 680 130 ÷ 95

FSC 200-345 110 500 ÷ 1000 50 ÷ 32

FSC 200-345 200 500 ÷ 1150 70 ÷ 45

FSC 200-465 315 500 ÷ 1000 110 ÷ 75

FSC 200-520 400 500 ÷ 1000 140 ÷ 110

FSC 200-590 400 500 ÷ 900 140 ÷ 110

FSC 250-410 250 800 ÷ 1600 70 ÷ 48

FSC 250-445 450 800 ÷ 1900 100 ÷ 65

FSC 250-550 640 800 ÷ 1600 150 ÷ 105

FSC 300-485 600 1200 ÷ 2700 100 ÷ 65

FSC 300-525 1100 1500 ÷ 3100 135 ÷ 90

Technical characteristics at 2900 rpm

ModelP

[kW]

Q

[m3/h]

H

[m]

FSC 125-250 110 300 ÷ 600 75 ÷ 50

FSC 125-270 200 300 ÷ 700 100 ÷ 65

FSC 125-335 250 300 ÷ 600 140 ÷ 110

FSC 125-375 355 300 ÷ 600 160 ÷ 130

FSC 150-295 250 600 ÷ 1000 100 ÷ 60

FSC 150-320 400 600 ÷ 1100 130 ÷ 90

Technical characteristics at 3550 rpm

ModelP

[kW]

Q

[m3/h]

H

[m]

FSC 125-335 250 300 ÷ 550 160 ÷ 120

FSC 125-250 200 300 ÷ 750 110 ÷ 70

117

Page 118: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

127

Model [Kg]A H J K LG IFEDC

Multi25 3

Multi25 4

Multi25 5

16.2

17.3

17.9

398

422

441

11/4”

11/4”

11/4”

197

197

197

193

193

193

125

125

125

11/4”

11/4”

11/4”

125

125

125

191

191

191

182

182

182

42

42

42

170

170

170

194

205

226

B

Applications

Spray irrigation systems,

hydropneumatic sets

and industrial installations.

Materials

Pump body and impellers in stainless

steel AISI 304.

Diffusers in technopolymer.

Mechanical seal in graphite and alumine.

Motor housing in aluminium L-2521.

Flanges, suction and discharge

connections in cast iron.

Motor shaft in stainless steel AISI 420.

Multi35N 8 and 10 / Multi55N 6

and 7: in stainless steel AISI 303.

Limitations

Maximum temperature of liquid: 40 °C

Equipment

Supplied with oval counter flanges

DIN 2558.

Multi Surface Vertical

Quiet-running vertical multi-stage centrifugal pumps, supplied with flanges

Motor

Asynchronous, two poles.

IP 44 protection.

Class F insulation.

Continuous operation.

Efficiency IE2.

Multi25: Single-phase version up to

1.5 HP built-in thermal protection.

Multi35N: Single-phase version up to

1 HP built-in thermal protection.

Energy Index MEI 0,4 for Multi 25/35.

Energy Index MEI 0,4 for Multi 55.

L

K

J

IH

G

F

A

E

D

C

B

Multi25

Multi25

G

F

B

AI

HE

D

C

Multi35 N 3. 4. 5. 6

Multi55 N 3. 4. 5. 6

G

F

AI

HE

D

C

B

Multi35 N 8. 10

Multi55 N 8. 10Model [Kg]

Multi35 3 N

Multi35 4 N

Multi35 5 N

Multi35 6 N

Multi35 8 N

Multi35 10 N

Multi55 3 N

Multi55 4 N

Multi55 6 N

Multi55 7 N

A HG IFEDC

20.2/20

22.4/20.4

25.1/22.7

25.7

32.6

39.4

25.7/23.3

26.6

35.4

39.7

487

511.5

536

561

657.5

707.5

531

571

696

736

11/2”

11/2”

11/2”

11/2”

11/2”

11/2”

11/2”

11/2”

11/2”

11/2”

201

201

201

201

201

201

201

201

201

201

11/4”

11/4”

11/4”

11/4”

11/4”

11/4”

11/4”

11/4”

11/4”

11/4”

133

133

133

133

133

133

133

133

133

133

37

37

37

37

37

37

37

37

37

37

203

203

203

203

233

233

203

203

203

203

184

184

184

184

184

184

184

184

184

184

201.5

226

250.5

275

323

373

245

285

362

402

B

Multi35 N / Multi55 N

Dimensions and weights

118

Page 119: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

128

Multi Surface Vertical

Multi35 N

Hydraulic performance table

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

4.5

5.8

6.4

1.9

2.3

2.5

3.2

3.9

4.2

0.55

0.75

0.9

0.75

1

1.25

1.0

1.2

1.4

0.9

1.1

1.3

16

16

16

c

[μF] m3/h

l/min

1.00.5

178

1.5

25

2.0

33

2.5

42

3.5

58

4.5

75

38.2

52.7

66.5

38

51

54

35.7

48.2

61.2

33.5

45.8

57.5

31

42

52.5

25

33

41

17

22

27

7.2

9

12

5.5

92

mw

c

Multi25 3

Multi25 4

Multi25 5

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

9.6 3.8

4.8

7

9

6.6

8.3

12.1

15.6

1.5

2

3

4

2

3

4

5.5

2.1 2.1

2.8

4.2

4.9

30

c

[μF] m3/h

l/min

3.01.2

5020

4.5

75

6.0

100

9.0

150

12

200

15

250

37

50

77

90

35

47

73

86

33

45

70

82

31

43

66

78

28

39

60

70

24

33

52

60

18

26

43

50

10

16

29

35

18

300

mw

c

Multi55 3 N

Multi55 4 N

Multi55 6 N

Multi55 7 N

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

6.7

8.4

10.2

2.6

3.1

4

4.8

6.5

8.9

4.5

5.3

6.9

8.3

11.9

15.4

0.75

1.1

1.5

2

3

4

1

1.5

2

3

4

5.5

1.5

1.8

2.3

1.4

1.8

2.2

2.7

3.6

4.9

25

25

30

c

[μF] m3/h

l/min

2.01.0

3317

3.0

50

4.5

75

6.0

100

7.5

125

9.0

150

39

54

65.4

82

108

134

37.5

51

63.5

79.5

105

130

35.5

48

60

76

101

125

31.5

44

54.5

69

93

117

27

37

46

61

85

105

21

29.5

36

49

70

90

15

21

26.2

36.7

53

70

7

11.8

15

23

35

47

10.5

175

mw

c

Multi35 3 N

Multi35 4 N

Multi35 5 N

Multi35 6 N

Multi35 8 N

Multi35 10 N

10

8

6

5

4

3

Performance curves at 2900 rpm

Multi25

Multi55 N

7

6

4

3

5

4

3

119

Page 120: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

129

Multi ESD Surface Vertical

Pump with integrated inverter

Applications

Constant water supply in dripping

irrigation installations.

Industrial applications where constant

pressure is required.

Materials and motor

As per the pump and Speedrive pages.

Efficiency IE3.

Energy Index MEI 0,4 for Multi 25/35.

Energy Index MEI 0,4 for Multi 55.

Equipment

Pumps supplied with VDF integrated.

Pressure transducer must be ordered

separately.

Voltage range

Low voltage: disconnect at 180 V (M2)

310 V (T2/T3).

Automatic reset: 195 V (M2) 335 V (T2/T3).

High voltage: disconnect at 270 V (M2)

485 V (T2/T3).

Automatic reset: 250 V (M2) 475 V (T2/T3).

Operation principle

The VFD increase and decrease

the speed of the motor according to

the installation demand supplying

constant pressure.

The input signal comes from a pressure

transducer installed on the discharge

pipe.

Speedrive are manufactured with all the

protections in order to protect the pump,

from dry running, temperature, over

intensity, etc.

Performance area Multi ESDM at 2900 rpm Performance area Multi ESD at 2900 rpm

Hydraulic performance table

Model Pump UnitP2

VfdPump

[kW] Suction Discharge

Multi ESD 25 4 Multi 25 4 1 0,75 M2/T2 1 1/2” 1 1/4”

Multi ESD 25 5 Multi 25 5 1 0,92 M2/T2 1 1/2” 1 1/4”

Multi ESD 35 4 Multi 35 4 1 1,1 M2/T2 1 1/2” 1 1/4”

Multi ESD 35 5 Multi 35 5 1 1,5 M2/T2 1 1/2” 1 1/4”

Multi ESD 35 6 Multi 35 6 1 2,2 T2 1 1/2” 1 1/4”

Multi ESD 35 8 Multi 35 8 1 3 T3 1 1/2” 1 1/4”

Multi ESD 35 10 Multi 35 10 1 4 T3 1 1/2” 1 1/4”

Multi ESD 55 3 Multi 55 3 1 1,5 T2 1 1/2” 1 1/4”

Multi ESD 55 4 Multi 55 4 1 2,2 T2 1 1/2” 1 1/4”

Multi ESD 55 6 Multi 55 6 1 3 T3 1 1/2” 1 1/4”

Multi ESD 55 7 Multi 55 7 1 4 T3 1 1/2” 1 1/4”

Pressure transductor 4-20 mA (10 bar)

86420

140120100806040200 Q [l/min]

Q [m3/h]

10

10

20

20

30

30 40

Imp g.p.m.

U.S. g.p.m.

60

50

40

30

20

10

0

H

[mca]

200

150

100

50

0

H

[ft]

600

400

200

0

H

[kPa]

Q [l/min]

151050

300250200150100500

Q [m3/h]

20 40 60

20 40 60 80

Imp g.p.m.

U.S. g.p.m.

80

60

40

20

0

H

[mca]

800

600

400

200

0

H

[kPa]

250

200

150

100

50

0

H

[ft]

120

Page 121: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

130

Multi ESD Surface Vertical

Multi ESD 25

Multi ESD 35

Model A B C D E F G Suction Discharge Kg

Multi ESD 25 4M 420 205 42 170 290 213 125 1 1/4” 1 1/4” 20.3

Multi ESD 25 4T 420 205 42 170 290 213 125 1 1/4” 1 1/4” 20

Multi ESD 25 5M 442 226 42 170 290 213 125 1 1/4” 1 1/4” 21.1

Multi ESD 25 5T 442 226 42 170 290 213 125 1 1/4” 1 1/4” 20.9

Multi ESD 55

Model A B C D E F G Suction Discharge Kg

Multi ESD 55 3M 531 245 37 184 352 228 133 1 1/2” 1 1/4” 26.3

Multi ESD 55 3T 531 245 37 184 352 228 133 1 1/2” 1 1/4” 28.7

Multi ESD 55 4T 571 285 37 184 352 228 133 1 1/2” 1 1/4” 29.6

Multi ESD 55 6T 696 362 37 184 352 228 133 1 1/2” 1 1/4” 38.4

Multi ESD 55 7T 736 402 37 184 352 228 133 1 1/2” 1 1/4” 42.7

Model A B C D E F G Suction Discharge Kg

Multi ESD 35 4M 511.5 226 37 184 312 213 133 1 1/2” 1 1/4” 25.4

Multi ESD 35 4T 511.5 226 37 184 312 213 133 1 1/2” 1 1/4” 23.4

Multi ESD 35 5M 536 250.5 37 184 312 213 133 1 1/2” 1 1/4” 28.1

Multi ESD 35 5T 536 250.5 37 184 312 213 133 1 1/2” 1 1/4” 25.7

Multi ESD 35 6T 561 275 37 184 312 213 133 1 1/2” 1 1/4” 28.7

Multi ESD 35 8T 657.5 323 37 184 312 213 133 1 1/2” 1 1/4” 35.6

Multi ESD 35 10T 707.5 373 37 184 312 213 133 1 1/2” 1 1/4” 42.4

Dimensions and weights

D

A

B

C

D

EF

G

G

D

A

B

C

D

EF

G

G

D

A

B

C

D

EF

G

G

121

Page 122: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

148

Multi VE Surface Vertical

Applications

Spray irrigation systems

and hydropneumatic sets.

Materials

Pump shaft, impellers, pump body

and protection grid in stainless steel

AISI 304.

Suction body, discharge body

and motor-pump coupling in cast iron.

Diffusers in technopolymer.

Motor housing in aluminium.

Rods F 212 Zn.

Pump motor coupling system V18.

EnergyIndex MEI 0, 4.

Quiet-running vertical IN-LINE multi-stage centrifugal pumps

Motor

Asynchronous, two poles.

IP 54 protection.

Class F insulation.

Continuous operation.

Efficiency IE2.

Limitations

Maximum temperature of liquid: 40 °C.

Equipment

Supplied with counter flanges

and gaskets.

Dimensions and weights

KgA: Hydraulic / KgB: Hydraulic + motor

Model A B C D E F G KgA KgB

Multi VE94 5 450 700 176 127 280 190 155 20 34

Multi VE94 6 486 738 176 127 280 190 155 21 35

Multi VE94 8 563 838 176 127 280 190 155 23 38

Multi VE94 10 666 974 194 138 280 190 155 30.4 51

Multi VE94 11 703 1010 194 138 280 190 155 31.4 52

Multi VE94 13 780 1086 194 138 280 190 155 33.3 57

Multi VE94 14 816 1134 220 146 280 190 155 36 66

Performance curves at 2900 rpm

14

13

11

10

8

6

5

A

G

F

E

D

C

B

190

155

80 4

4

Ø18 R1”Gas

Multi VE-94/10...94/14

Flange DIN 2566

Multi VE-94/5...94/8

Flange DIN 2558

150

110

190

200

155

155

190

100

50 4

4

Ø12

M12 Ø14

R1”Gas

130

100

95

Hydraulic performance table

Model

I

[A]

P1

[kW]P2 l/min 25 50 100 125 150 175 200 225

3~

230 V

3~

400 V

3~

692 V

3~

400 V[kW] [HP] m3/h 1.5 3.0 6.0 7.5 9.0 10.5 12 13.5

Multi VE94 5 6 3.5 2 1.5 2

mw

c

47 46 41 37 32 25 18 9

Multi VE94 6 6.7 3.9 2.3 1.5 2 56 55 49 44 38 31 22 13

Multi VE94 8 8.9 5.2 3 2.2 3 75 73 63 56 49 40 30 18

Multi VE94 10 11.7 6.8 3.9 3 4 93 91 81 72 62 50 36 22

Multi VE94 11 12.4 7.2 4.4 3 4 105 102 91 82 70 56 42 26

Multi VE94 13 8.6 5 5 4 5.5 123 120 107 97 85 68 51 32

Multi VE94 14 9.7 5.4 5.5 5.5 7.5 132 129 118 109 95 77 57 35

* VE94 5 to VE94 11 optional 230 1ph motors

122

Page 123: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

149

POOL

& WELLNESS

Page 124: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

151

Basic/Niper Swimming Pool

Quiet running single-stage centrifugal pump

Applications

Recirculation of water from small

transportable pools.

Materials

Pump body, seal mounting, impeller

and pump foot in technopolymer.

Motor shaft in stainless steel AISI 420.

Mechanical seal in graphite and alumine.

Motor housing in aluminium.

Niper: diffuser in technopolymer.

Motor

Asynchronous, two poles.

IP 55 protection.

Class F insulation.

Continuous operation.

Built-in thermal protection.

Equipment

Supplied with suction and discharge

unions for 32 and 38 mm.

Ø flexible pipes.

Niper: 38 mm Ø, hose tail connections

for flexible hoses.

Dimensions and weights

Basic

Model A I [Kg]HGFEDC

305 32 4.53832389094204219

B

B

CA

D

E

F G

HI

Basic

Niper 1 350

Niper 2 400

Niper 2 450

Model A [Kg]HGFEDC

405

405

415

5.1

5.1

5.8

40

40/50

40/50

40

40

40

158

158

158

231

231

231

250

250

250

204

204

204

262

262

262

B

Niper 1 / Niper 2

B

CA

DE

F

G

H

124

Page 125: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

152

Basic/Niper Swimming Pool

Performance curves at 2900 rpm

Basic Niper 1/Niper 2

Hydraulic performance table

Basic

1.34

1.53

1.97

0.27

0.32

0.43

0.18

0.18

0.25

0.25

0.25

0.33

6

6

12

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

9.1

9.6

10.6

1.5

25

3.0

50

4.5

75

6.0

100

7.5

125

9.0

150

10.5

175

8.2

9.1

10.3

6.6

8

9.8

3.7

6.1

8.5

3.8

6.9

0.6

5.1 2.8 1.2

11.4

190

mw

c

Niper 1 350

Niper 2 400

Niper 2 450

Niper 1 / Niper 2

1.0 0.2 0.15 0.20 6

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

5.3

0.6

10

4.7

1.5

25

4.3

2.1

35

3.7

3.0

50

3.4

3.6

60

2.7

4.5

75

2.3

5.1

85

1.3

6.0

100

Basic mwc

350 400 450

125

Page 126: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

156

Performance curves at 2900 rpm

S3 Magnus Swimming Pool

Self-priming pumps for swimming pools at 1450 rpm

Applications

Recirculation and filtering of large pools.

Rotational speed of the motor at

1450 rpm for a slower water flow and

a more effective filtration.

Materials

Pump body, pump foot, volute, casing

made of fibreglass-reinforced

polypropylene.

Polyethylene filter basket.

Polycarbonate filter cover.

Noryl impeller (bronze on request).

Motor shaft in stainless steel AISI 316.

Mechanical seal: carbo ceramic.

Features

Flanged connectors.

Counter flanges available on request

550, 750 and 1000 models can be

supplied with bronze impeller at extra cost.

Motor

Asynchronous, four-pole.

Class F insulation.

IP 55 protection.

Continuous operation.

Efficiency IE1, IE2 on request.

Limitations

Maximum suction height: 4 m.

Also for saltwater (max. 6 g/litres of salt).

Dimensions and weights

Model A B C D E F G H I J K Dna Dnm [Kg]

S3 Magnus 300 420 405 508 310 265 505 335 300 450 590 370 110 110 42.5

S3 Magnus 400 420 405 508 310 265 505 335 300 450 590 370 110 110 44.5

S3 Magnus 550 420 405 508 330 265 505 335 300 450 590 370 110 110 53.4

S3 Magnus 750 420 405 508 380 265 505 335 300 450 590 370 110 110 66

S3 Magnus 1000 420 405 508 380 265 505 335 300 450 590 370 110 110 76

Hydraulic performance table

Model

I

[A]P2 l/m 66.6 100 133.2 166.6 200 233.2 266.4 300

3~

400 V[kW] [HP] m3/h 4 6 8 10 12 14 16 18

S3 Magnus 300 5.5 2.2 3

mw

c

78 70 60 48 35 18

S3 Magnus 400 7.4 3 4 88 83 75 65 52 40 20

S3 Magnus 550 8.8 4 5.5 145 125 110 90 60 10

S3 Magnus 750 12 5.5 7.5 165 152 136 115 74 65 10

S3 Magnus 1000 15.8 7.5 10 175 165 155 138 120 95 52 5

Bronze impeller (only available in models 550, 750 and 1000)

C

I

J

A

E

F

G

H

D K

Q [m3/h]1501251007550250

300

400

550 750

1000

H[m]18

16

14

12

10

8

6

4

2

0

B

126

Page 127: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

157

Star CF/BR 2 Swimming Pool

Cast iron monobloc centrifugal pumps c/w pre-filter

Applications

Recirculation and filtering of water from

medium to large swimming pools,

aquatic attractions & similar places.

The bronze version is ideal for sea water

and pools that use salt electrolysis.

Material

Pump body and pre-filter in cast iron or

bronze G-CuSn 5.

Pre-filter, coupling & impeller in cast

iron or bronze G-CuSn 5.

Shaft & pre-filter sieve/bolts in stainless

steel AISI 316.

Mechanical seal in carbon/ceramic.

Options (upon request)

Mechanical seal in silicon carbide or

tungsten carbon.

Special bronze alloy.

Vertical mounted.

Motor

Standard asynchronous motor.

IP 55 protection.

Class F insulation.

IE1 as standard with IE2 on request.

Rotation 2850 rpm.

50-60 Hz.

2.2 to 11 kW.

Range

Q max = 200m3/h.

H max = 23 m.

Limitations

Liquid temperature range

-15 to +120 °C.

Ambient temperature max 40 °C.

* For 3 & 4 HP models is recommended to install at lest Ø 90 mm pipes

Hydraulic performance table

ModelI

[A]P2

m3/h 6 8 10 12 14 16 18 20 22 DNA DNM

Cast Iron Bronze1~

230 V

3~

400 V[kW] [HP]

CF-2 300 BR-2 300 9 6.2 2.2 3

mw

c

61 54 51 46 35 29 DN80* DN80*

CF-2 400 BR-2 400 12 6.9 3 4 70 64 59 55 49 42 30 DN80* DN80*

CF-2 550 BR-2 550 16.5 9.5 4 5.5 95 90 84 77 65 54 32 DN125 DN100

CF-2 551 BR-2 551 16.5 9.5 4 5.5 128 121 107 90 69 30 DN125 DN100

CF-2 750 BR-2 750 21.7 12.5 5.5 7.5 159 152 135 125 109 88 60 DN125 DN100

CF-2 1000 BR-2 1000 15.5 7.5 10 180 175 162 149 135 119 101 78 DN125 DN100

CF-2 1250 BR-2 1250 19 9.2 12.5 200 196 182 165 150 136 110 95 DN125 DN100

CF-2 1500 BR-2 1500 23 11 15 216 210 200 185 171 155 137 118 95 DN125 DN100

Dimensions and weights

ModelA B C D E F G H I J

Intake Output Weight

Cast Iron Bronze ØDNA DA PA N°T ØT ØDNI DI PI N°T ØT CI BR

CF-2 300 BR-2 300 465 890 425 80 605 410 275 200 320 250 80 200 160 4 18 80 200 160 4 18 75 90

CF-2 400 BR-2 400 465 910 425 80 605 410 275 200 320 250 80 200 160 4 18 80 200 160 4 18 79 96

CF-2 550 BR-2 550 500 985 455 105 635 435 280 215 330 280 125 250 210 8 18 100 220 180 8 18 104 124

CF-2 551 BR-2 551 500 985 455 105 635 435 280 215 330 280 125 250 210 8 18 100 220 180 8 18 104 124

CF-2 750 BR-2 750 500 1050 455 105 675 435 280 215 330 280 125 250 210 8 18 100 220 180 8 18 121 140

CF-2 1000 BR-2 1000 525 1095 470 120 725 465 325 275 345 330 125 250 210 8 18 100 220 180 8 18 140 163

CF-2 1250 BR-2 1250 525 1130 470 120 725 465 325 275 345 330 125 250 210 8 18 100 220 180 8 18 148 163

CF-2 1500 BR-2 1500 525 1130 470 120 725 465 325 275 345 330 125 250 210 8 18 100 220 180 8 18 148 168

Performance curves at 2850 rpm

300 400 550 551

750 1000 1250

1500

22

20

18

16

14

12

10

8

6

4

2

H

[m]

2001751501251007550250 Q [m3/h]

A

B

DA

F

G

ØT

ØD

NA

PA

E

C

J

I

PI

H

DI

ØDNI

D

127

Page 128: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

158

Star CF 4 Swimming Pool

Cast iron monobloc centrifugal pumps c/w pre-filter

Applications

Recirculation and filtering of water from

medium to large swimming pools,

aquatic attractions & similar places.

Materials

Pump body and pre-filter in cast iron.

Pre-filter, coupling & impeller in cast iron.

Shaft & pre-filter sieve/bolts in stainless

steel AISI 316.

Mechanical seal in carbon/silicon carbide.

Options (upon request)

Bronze impeller.

Mechanical seal in tungsten carbon,

AISI 316, EPDM, viton etc.

Special bronze alloy.

Vertical mounted.

Motor

Standard asynchronous motor.

IP 55 protection.

Class F insulation.

IE1 as standard with IE2 on request.

Rotation 1450 rpm.

50-60 Hz.

2.2 to 18.5 kW.

Range

Q max = 150 m3/h (350 m3/h Vertical).

H max = 19 m (22 m Vertical).

Limitations

Liquid temperature range

-15 to +120 °C.

Ambient temperature 40 °C.

Performance curves at 1450 rpm

A

B

DA

F

G

ØT

ØD

NA

PA

E

C

J

I

PI

H

DI

ØDNI

D1000

2000

2500

1500

350300250200150100500 Q [m3/h]

20

18

16

14

12

10

8

6

4

2

H

[m]

300

400 550

750

552

Hydraulic performance table

Model

I

[A]P2

m3/h 9 10 12 14 15 16 18 20 21 DNA DNM1~

230 V

3~

400 V[kW] [HP]

CF-4 300 9.4 5.3 3 2.2

mw

c

54 50 44 30 20 DN65 DN50

CF-4 400 12.5 6.9 4 3 70 67 50 36 20 DN90 DN65

CF-4 550 17 9.2 5.5 4 94 72 66 64 20 DN90 DN65

CF-4 552 17 9.2 5.5 4 120 110 79 28 DN100 DN90

CF-4 750 23 12 7.5 5.5 124 104 90 72 DN100 DN90

CF-4 1000 15.5 10 7.5 210 175 130 90 60 DN125 DN100

CF-4 1500 21.8 15 11 215 200 190 180 150 120 60 DN125 DN100

CF-4 2000 32 20 15 320 300 275 260 210 102 DN150 DN125

CF-4 2500 39 25 18.5 360 340 310 280 220 190 DN150 DN125

Dimensions and weights

Model A B C D E F G H I JIntake Output

WeightØDNA DA PA N°T ØT ØDNI DI PI N°T ØT

CF-4 300 465 979 430 70 639 360 224 212 265 302 66 185 145 4 18 50 165 125 4 18 94

CF-4 400 442 998 398 95 616 450 310 250 320 333 80 200 160 4 18 65 185 145 4 18 105

CF-4 550 442 1021 398 95 616 450 310 250 320 333 80 200 160 4 18 65 185 145 4 18 110

CF-4 552 490 1138 443 95 733 430 346 280 345 365 100 200 180 8 18 80 200 160 8 18 140

CF-4 750 490 1248 443 95 733 430 346 280 345 365 100 200 180 8 18 80 200 160 8 18 155

CF-4 1000 500 1258 440 120 743 480 310 280 360 392 125 250 210 8 18 100 220 180 8 18 176

CF-4 1500 515 1413 455 120 788 505 335 315 400 424 125 250 210 8 18 100 220 180 8 18 272

CF-4 2000 585 1528 525 120 858 611 440 315 400 472 150 250 240 8 18 125 250 210 8 18 355

CF-4 2500 585 1558 525 120 858 611 440 315 400 472 150 250 240 8 18 125 250 210 8 18 385

128

Page 129: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

159

Star F/V Pre-filters Swimming Pool

Cast iron pre-filter

General

Intel and outlet clamps according

to din 2501 with connections from

DN65-200.

With three closing handles in

AISI 316 (depending on model) for a

perfect lid seal.

Materials

Pot and pre-filter in cast iron

Strainer in stainless steel AISI 316.

Options (upon request)

Bronze pot.

Dimensions

Model DI Do HI Ho A B C De Dt ØT N°T

F65/65 65 65 250 120 360 253 380 185 145 18 4

F80/80 (4T) 80 80 250 120 360 253 380 200 160 18 4

F80/80 (8T) 80 80 250 120 360 253 380 200 160 18 8

F100/100 100 100 270 155 360 253 380 222 180 18 8

F125/125 125 125 270 155 360 253 380 250 210 18 8

F150/150 150 150 380 190 500 330 460 285 240 22 8

F200/200 200 200 380 190 500 330 460 340 295 22 8

V65/65 65 65 151 357 328 310 231 285 145 M16 4

V80/80 80 80 151 357 328 310 231 285 160 M16 8

V100/100 100 100 151 357 328 310 231 285 180 M16 8

V125/125 125 125 151 357 328 310 231 285 210 M16 8

V150/150 150 150 151 357 328 310 231 285 240 M20 8

A A

DD

C

C

FV

Hs Hs

Ds

Pt

ØT

B

DN

Ds

B

He

He

DeDe

129

Page 130: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

160

Performance curves at 2900 rpm

APCP Swimming Pool

Tarpaulin emptying pump

Applications

Completely automatic pump for

emptying pool-covering tarpaulins.

Automatically activated when the water

reaches 50 mm in height.

Lightweight and compact in size, this

is the ideal solution for the drainage of

seepage water.

Materials

Pump housing made of polypropylene.

Motor housing in AISI 304 stainless

steel.

Motor shaft in 1.4101 steel.

O-rings in NBR.

Impeller in Noryl.

Dimensions: 210 x 305 x 305 mm.

Cable: 10 metres (H07 RN-F).

IP 68 protection.

Pump outlet: 1” (hose nozzle provided).

Complete with internal float.

Dimensions and weights

Model A B C Kg

APCP 302 302 209 6.8

Hydraulic performance table

Model

I

[A]

P1

[kW]l/min 10 20 30 40 50 60 80 95

1~

230 V

1~

230 Vm3/h 0.6 1.2 1.8 2.4 3 3.6 4.8 5.7

APCP 1.2 0.29

mw

c

6.4 6.2 6.1 5.8 5.4 4.7 3 0.5

A B

1” FNTP

C

130

Page 131: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

165

Pool Swimming Pool

Quiet-running horizontal single-stage centrifugal pumps

Motor

Asynchronous, two poles.

IP 55 protection.

Class F insulation.

Continuous operation.

Single-phase with built-in thermal

protection.

Limitations

Self-priming up to 9 m.

Applications

Operation with swimming pool cleaners,

sea water, chloric water, demineralised

water and ozone water.

Materials

Pump body, impellers and diffusers

in technopolymer.

Motor shaft in stainless steel AISI 420.

Mechanical seal in graphite and alumine.

Motor housing in aluminium.

Windings impregnated with polyester

resin.

Pump body screws, nuts, washers

and bushes in stainless steel AISI 316.

Hydraulic performance table

I [A]

1~

230 V 400 V230 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

0.60.3

105

0.9

15

1.2

20

1.5

25

1.8

30

2.4

40

5 1.93.3 1.1 1.0 0.97 1.0 16 47mwc 43 40 37 35 33 28 26

2.7

45

Pool

Performance curves at 2900 rpm

Pool

Model [Kg]A HGFEDC

343 1” 8.21”84.7147196190201.5

B

A

B

C

DE

F

G

H

Dimensions and weights

131

Page 132: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

166

Dosing Pumps HC Hydromassage/Spa

HC dosing pumps

Model HC150 1.5-05 Solenoid Dosing Pump

Analogue solenoid driven catering pump at constant

flow rate.

High impact PBT housing suitable for high temperature

environments & fluids.

Double scale pulse reduction 0-100% or 0-20%.

IP 65 protection.

Analogue control & setting via one Knob and LED.

Manual air bleed valve for quick priming.

Model HC 897 Dosing Pump

Digital multifunction solenoid driven catering pump with

constant & proportional modes pulses, mA, On/Off

cyclic, PH & Rx.

High impact PBT housing suitable for high temperature

environments and fluids.

Level probe input.

Digital injection frequency setting 0-100%.

Digital control and settings by four keys, 7 segment

LED display.

IP 65 protection.

Manual air bleed valve for quick priming.

Model HC 201 Dosing Pump

Programmable microprocessor with several control

options.

Electronic frequency control.

Multifunction dosing modes.

Digital keypad control.

Manual air bleed valve for quick priming.

Manual stroke length adjustment.

Stop/start button.

Low level facility.

LCD display.

IP 65 protection.

Also available 110 Vac.

Power supply for all of the above:

are supplied 240 Vac 50/60Hz.

All complete with foot valve strainer and

injection fitting.

Horizontal mounting as standard, shelf

support bracket available at extra cost.

132

Page 133: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

168

Tiper 0/2/15 Hydromassage/Spa

Single-stage centrifugal pumps with complete selfdrainning

Equipment

Complete with suction and discharge

connections, metric or imperial.

Options

On/off switch rear connection and level

sensors via pneumatic or electrical

devices.

Variable speed MV version also

available.

Applications

Compact hydromassage units.

Materials

Suction and discharge mountings,

impeller and motor mountings

in technopolymer.

Motor shaft in stainless steel AISI 420.

Motor housing in aluminium.

Tiper 0/15:

Mechanical seal in graphite and steatite.

Tiper 2:

Mechanical seal in graphite and alumine.

Motor

Asynchronous, two poles.

IP 55 protection. Class F insulation.

Continuous operation.

Built-in thermal protection.

Limitations

Insulation capable of resisting over

3750 V.

Tiper 0 70

Tiper 0 90

Model A

100

100

[Kg]

3.9

4.4

H

21/4”

21/4”

J

74

74

L

14

14

K

9

9

G

130

130

G1

160

160

I

21/4”

21/4”

F

88

88

E

47

47

E1

26.5

26.5

D

312

312

C

135

135

154.5

154.5

B

102

101

A1

Tiper 0

Tiper 0 70

A

B

C

E

D

F

G

H

I

D

F

H

I

G1 J

K

B

C

A1

E1

L

Tiper 0 90

A

B

C

D

E

F

GH

I

J

Tiper 15 1

Tiper 15 2

Tiper 15 3

Model A

340

340

340

C

200

200

200

E

181

181

181

H

326

326

326

L

100

100

100

F

80

80

80

J

32

32

32

K

50

50

50

G

7

7

7

[Kg]

5.6

5.9

6.3

I

176.5

176.5

176.5

M

125.5

125.5

125.5

D

36.5

36.5

36.5

114.7

114.7

114.7

B

Tiper 15

AB

C

D

E F

I

H

G

M

L

K

Tiper 2 75

Tiper 2 125

Model A

124

124

[Kg]

3.9

4.4

I

21/4”

21/4”

J

21/4”

21/4”

H

130

130

F

120

120

G

120

120

E

50

50

D

378

378

215

215

C

187

187

B

Tiper 2

Dimensions and weights

133

Page 134: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

169

Hydraulic performance table

2.9

3.74

0.64

0.85

0.37

0.75

0.5

1

12

12

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

9.5

10.5

3.0

50

8.3

9.4

6.0

100

7.1

8.4

9.0

150

6.5

7.8

10.5

175

5.7

7.1

12

200

3.6

5.4

15

250

3.3

18

300

1.9

19.8

330

mw

cTiper 0 70

Tiper 0 90

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

1.5

25

3.0

50

6.0

100

9.0

150

12

200

15

250

18

300

19.5

325

mw

c

1.7

2.3

3

0.36

0.5

0.7

0.18

0.37

0.55

0.25

0.5

0.75

6

10

12

8

8.6

9.5

7.3

8

9

6

6.9

7.9

4.3

5.6

6.8

2.6

4.2

5.3

2.7

3.9 2.2 1.5

Tiper 15 1

Tiper 15 2

Tiper 15 3

5.3

5.6

1.2

1.5

0.55

0.90

0.75

1.25

16

16

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

12.3

14.2

5.0

83

11.1

13.2

8.0

133

10

12

11

183

8.5

10.6

14

233

6.5

9

17

283

5

7

20

333

2.5

5

23

383

2.7

26

433

mw

cTiper 2 75

Tiper 2 125

Performance curves at 2900 rpm

Tiper 15

Tiper 2

Tiper 0/2/15 Hydromassage/Spa

Tiper 0

907075 125

12 3

134

Page 135: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

135

Page 136: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

170

Page 137: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

171

PRESSURE

BUILDING

SERVICES

Page 138: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

173

Optimatic 05 Pressure

Automatic pressure unit

Description

The electronic Optimatic 05 starts

and stops the pump and monitors

the pressure and flow rate within the

system and protects the pump against

dry running. When a tap is opened it

starts the pump and keeps it running,

delivering constant flow, even at low

flow rates.

It stops the pump when the flow rate

demanded is near zero.

A special, no maintenance, patent

pending membrane guarantees a high

level of protection against overpressure.

The large accumulation volume available

is essential in preventing excessive

running/stopping due to small losses

within the system. It is therefore no

longer necessary to fit a pressure vessel.

Equipment

Yellow led power.

Green led on.

Red led failure.

Tactile push button for manual start.

Electronic circuit group with protection

cover, easily replaceable.

Reserve against leaks in the installation.

Adjustable start pressure.

Technical features

Voltage: 230 V / 127 Vac.

Max. current: 16 (8) Amps.

Start pressure: 1.5 - 3.0 bar (adjustable).

Protection: IP 65.

Working temperature: 0 - 60 deg c.

Max flow rate: 10.000 L/hr.

Connections: G1’’ male ISO 228.

Max. operating pressure 10 bar - 1 MPa.

Weight: 1.35 kg.

Protection against dry running

(Automatic reset) excessively frequent

starts.

Model A B C D E F

Optimatic 05 155 220 R1’’ 150 102 127

Performance curves at 2900 rpm

A

B

C

D

F

E

Dimensions

25

20

15

10

5

0

H

[m]

1086420 Q [m3/h]

138

Page 139: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

174

Pressure Sets Pressure

Domestic single pump boosting units

Applications

Automatic supply of water whilst

maintaining constant system pressure.

Configuration

These domestic booster units can be

built in various configurations using

different types of pumps, larger vessels

and alternative control devises.

For further assistance/selection

please contact our sales team.

Technical features

ModelCode P2 Size Vessel

PositionWith Vessel With Optimatic 05 [kW] [HP] Vessel Optimatic

Per 50/03 P50/30 P50 0.37 0.5 3 ltr 05 Vertical

Delta 505 D505/08 D505/05 0.37 0.5 8 ltr 05 Vertical

Delta 505 D505/24 0.37 0.5 24 ltr Horizontal

Delta 755 D755/08 D755/05 0.5 0.75 8 ltr 05 Vertical

Delta 755 D755/24 0.5 0.75 24 ltr Horizontal

Delta 1005 D1005/08 D1005/05 0.75 1 8 ltr 05 Vertical

Delta 1005 D1005/24 0.75 1 24 ltr Horizontal

Delta 1755 D1755/08 D1755/05 0.75 1 8 ltr 05 Vertical

Delta 1755 D1755/24 0.75 1 24 ltr Horizontal

Tecno 25.3 T25.3/18 T25.3/05 0.75 1 18 ltr 05 Vertical

Tecno 25.3 T25.3/24 0.75 1 24 ltr Horizontal

Tecno 25.4 T25.4/18 T25.4/05 0.9 1.25 18 ltr 05 Vertical

Tecno 25.4 T25.4/24 0.92 1.25 24 ltr Horizontal

Tecno 25.5 T25.5/18 T25.5/05 1.1 1.5 18 ltr 05 Vertical

Tecno 25.5 T25.5/24 1.1 1.5 24 ltr Horizontal

Aspri 25.3MB C25.3/18 C25.3/05 0.75 1 18 ltr 05 Vertical

Aspri 25.3MB C25.3/24 0.75 1 24 ltr Horizontal

Aspri 25.4MB C25.4/18 C25.4/05 0.92 1.25 18 ltr 05 Vertical

Aspri 25.4MB C25.4/24 0.92 1.25 24 ltr Horizontal

Aspri 25.5MB C25.5/18 C25.5/05 1.1 1.5 18 ltr 05 Vertical

Aspri 25.5MB C25.5/24 1.1 1.5 24 ltr Horizontal

Aspri 35.3 C35.3/24 1.1 1.5 24 ltr Horizontal

Aspri 35.3 C35.3/05 1.1 1.5 05

Aspri 35.4 C35.4/24 1.5 2 24 ltr Horizontal

Aspri 35.4 C35.3/05 1.5 2 05

Jet 100 J100/24 0.75 1 24 ltr Horizontal

139

Page 140: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

175

Tecnopres Pressure

Self-priming quiet-running horizontal multi-stage centrifugal pumps

Applications

To supply water at pressure in domestic

applications. With protection to prevent

the pump from operation when dry.

Materials

Pump body and impellers in stainless

steel AISI 304.

Motor shaft in stainless steel AISI 431.

Diffusers in technopolymer.

Mechanical seal in graphite and steatite.

Motor housing in aluminium.

O-rings in EPDM/NBR.

Motor

Asynchronous, two poles.

IP 55 protection.

Class F insulation.

Continuous operation.

Tecnopres 15: Single-phase version

with built-in thermal protection.

Tecnopres 25: Single-phase version

up to 1.25 HP with built-in thermal

protection.

Limitations

Maximum liquid temperature: 40 °C.

Self-priming up to 9 m.

Equipment

Complete with kit press and pressure

gauge.

Complete with 2 m of H07 RNF cable.

With valve resistant to impurities, dry run

protection and device to ensure pressure

water supply.

You must install a pressure vessel on the

discharge pipework.

8 ltrs for Tecnopres 15

18 ltrs for Tecnopres 25

Technical features

Electronic display with push button

and LEDs showing line, pump in

operation and failure.

Starting pressure:

Tecnopres 15: 1.8 bar (15/4),

2.3 bar (15/5).

Tecnopres 25: 2.3 bar.

Dimensions and weights

Model

Tecnopres 15 4

Tecnopres 15 5

Tecnopres 25 4

Tecnopres 25 5

[Kg]DNiØIG HFE DNaDCBA

10.3

11.2

10.3

11.2

F1”

F1”

F1”

F1”

195.8

219.1

216.3

242.6

9

9

9

9

148.5

148.5

148.5

148.5

88

88

88

88

216.3

216.3

216.3

216.3

244.5

244.5

268

289.5

F1”

F1”

F1”

F1”

197

197

206

206

256.3

279.6

276.8

303.1

107.5

107.5

107.5

107.5

A

B

D

C

E

F

H

G

ØI

DNi

140

Page 141: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

176

Hydraulic performance table

Performance curves at 2900 rpm

Tecnopres 15 Tecnopres 25

Tecnopres Pressure

5

45

4

Dry running protection

The pump stops automatically

when there is no water in the installation.

Pump body made entirely of stainless

steel to prevent oxidation due

to water-air contact.

Automatically closing self-priming valve

resistant to impurities.

It is closed automatically to prevent

unnecessary recirculation of water.

One outlet for domestic supply at pressure

Electronic device with reset

button and LEDs showing

line, pump in operation

and failure.

3.5

4.1

0.8

1

0.55

0.66

0.75

0.9

12

12

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

42

51

0.6

10

39

47

1.2

20

35

41.5

1.8

30

32

38

2.1

35

28

34

2.4

40

25

30

2.7

45

21

26

3.0

50

17

3.6

60

mw

cTecnopres 15 4

Tecnopres 15 5

6.8

7.4

1.5

1.7

0.95

1.1

1.25

1.5

16

25

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

44

56

0.9

15

42

55

1.8

30

40

53

2.7

45

37

49

3.6

60

33

43

4.5

75

28

37

5.4

90

22

29

6.3

105

15

20

7.2

120

mw

cTecnopres 25 4

Tecnopres 25 5

141

Page 142: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

177

Performance curves at 2900 rpm

Hydraulic performance table

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

0.3

5

0.6

10

0.9

15

1.5

25

1.8

30

2.1

35

2.7

45

3

50

3.6 0.75 0.55 0.75 1236

15

36

15

32

15

25.5

15

36

15

28

15

18.5

15

15

15

MAX

MINTecnoplus 15

Tecnoplus 15 Pressure

Centrifugal multi-stage with speed control

A horizontal, multiphase, centrifugal

pump with electronic regulation for

changing speed and with built-in

pressure sensor. It contains a device for

detecting and protecting against dry

operation, with sequential re-starts in

event of failure. Absorbs water hammer

effect on the installation.

Applications

Pressurising with constant pressure

of domestic water for houses,

semi-detached homes, apartments,

chalets and rural homes, etc.

Materials

Hydraulic body and impellers

in AISI 304.

Diffusers in thermoplastic.

Mechanical seal in graphite and ceramic.

O-nngs in NBR.

Motor

Asynchronous, two poles.

IP 55 protection.

Class F insulation.

Continuous operation.

Built-in thermal protector inside

the windings.

With 2 m cable H07 RNF 3 x 1 mm2.

Display with push button to increase

or decrease working pressure

(150 kPA - 350 kPA).

Limitations

Maximum suction lift 5 m for installation

with foot valve.

Maximum working pressure 6 bar.

Maximum suction pressure 2 bar intake

at suction point.

Water temperature from 4 °C to 35 °C.

Room temperature from -10 °C to 50 °C.

Motor characteristics 230 V / 50 Hz.

Electronics

Advanced ESPA Speed Drive technology,

enabling variable speed operation,

with automatic self-regulation which

maintains the constant pressure

required at all times in the home,

thanks to its pressure sensor.

Equipment

Complete with kit press and pressure

gauge.

Noise level 60-62 dBa at 1 meter.

You must install a pressure vessel

on the discharge pipework minimum

18 ltrs.

Model

Tecnoplus 15/4 M

[Kg]

10.5

I

9

J

243

M

G1”

L

G1”

K

196

A

439

H

88

G

253.8

F

241

E

216

D

200

C

261108

B

A

K J

L

B

C

D

M

F

EG

HI

The pump can operate atv any point inside the indicated area. The characteristic

curves depend on the delivery pressure. By way of example, the curves are

shown for delivery pressures of 150, 200 and 300 kPa.

The operating limit curve corresponds to the maximum rotating speed.

Dimensions and weights

142

Page 143: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

178

Tecnoplus 25 Pressure

A horizontal, multistage, centrifugal pump with frequency converter

Applications

Compact unit providing constant

pressure without fluctuations for

domestic applications, saving electricity.

Easy to install and plug&pump design.

Materials

Pump body and impellers in stainless

steel AISI 304.

Diffusors in thermoplastic.

Mechanical seal in graphite and ceramic.

O-rings in NBR and EPDM.

Motor

Asynchronous two poles 50/60 Hz.

IP 55 Protection.

Insulation class F.

Built-in thermal protector

inside the windings.

Continuous operation.

Three-phase motor 230 V

and single-phase supply 230 V.

Voltage range

Low voltage: Disconnect at 180 V.

Automatic Reset at 200 V.

High voltage: Disconnect at 260 V.

Automatic Reset at 240 V.

Equipment

A horizontal, multistage, centrifugal

pump with frequency converter with

keypad.

Built-in pressure sensor.

Built-in dry running control, pressure

gauge and dry running control with

sequential re-starts in the event

of failure.

Reduces water hamer effect on the

installations.

With 2 m cable HO7RNF 3 x 1 mm2.

You must install a pressure vessel

on the discharge pipework minimum

24 ltrs.

Limitations

Maximum suction 5 m lift when installed

with foot valve.

Maximum working pressure 6 bar.

Maximum intake pressure 2 bar.

Water temperature from 4 °C to 40 °C.

Room temperature from -10 °C to 50 °C.

Noise level dBa at l mtr.

Model

Tecnoplus 25 4M

[Kg]

15.5

A

277.5

H

148.5

G

1 1/4”

I

216

J

88

K

Ø 9

F

1”

E

190

D

107

C

467.5221

B

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] 2.7

45

3.6

60

4.5

75

5.4

90

6.3

105

7.2

120

6.8 1522283337401.5 0.92 1.25 16

m3/h

l/min

Tecnoplus 25 4M

J

K

H

I

C

E A

G

F

D

B

Performance curves at 2900 rpm

Hydraulic performance table

Dimensions and weights

143

Page 144: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

179

Applications

Pressurising of domestic water for

houses, semi-detached homes,

apartments, chalets and rural homes...

Materials

Outer casing, discharge body, impellers,

filter, discharge cover and motor casing

in stainless steel AISI 304.

Pump shaft in stainless steel AISI 303.

Diffusers in PPO.

Mechanical seal in graphite

and alumine/graphite/steatite/NBR/

AISI 304.

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Water-cooled motor.

Single-phase version with Klixon

(incorporated thermal protection).

Acuapres Pressure

Submersible multistage pumps with built-in pressure control

Limitations

Maximum working pressure 8 bar.

Ø of solids 2 mm.

Maximum 30 start-ups per hour.

Water temperature from 4 °C to 40 °C.

Motor characteristics 230 V.

Vertical installation only.

Equipment

Submersible multistage pump with

built-in pressure control and non return

valve.

Dry running control with four trials

if no water.

Oil chamber with two mechanical seals.

Model 4: starting pressure at 2 bar.

Model 6: starting pressure at 3 bar.

You must install a pressure vessel

on the discharge pipework minimum

24 ltrs.

Acuapres 4

Acuapres 6

493

560

10.6

12.4

1”

1”

126

126

Model A [kg]CB

A

B

C

Performance curves at 2900 rpm

12

16

3.5

5

1.7

2

I [A]

1~

230 V

3~

400 V

Model

P1 [kW]c

[μF] m3/h

l/min

41

60

0.6

10

37

55

1.2

20

32

47

1.8

30

26

37

2.4

40

22

32

2.7

45

19

26

3.0

50

10

15

3.6

60

6

9

3.9

65

mw

c

P2

0.5

0.9

0.75

1.2

[kW] [HP]

0.8

1.2

0.8

1.1

1~

230 V

3~

400 V

Acupares 4

Acuapres 6

Hydraulic performance table

Dimensions and weights

4

6

144

Page 145: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

180

Applications

Pressurising of domestic water for

houses, semi-detached homes,

apartments, chalets and rural homes...

Materials

Outer casing, discharge body, impellers,

filter, discharge cover and motor casing

in AISI 304 stainless steel.

Pump shaft in stainless steel AISI 303.

Diffusers in PPO.

Mechanical seal in aluminium oxide/

graphite/steatite/NBR/AISI 304.

Motor

Asynchronous, 2 pole. IP 68 protection.

Class F insulation. Continuous operation.

Water-cooled motor.

Single-phase version with Klixon

(incorporated thermal protection).

With level switch.

Limitations

Maximum working pressure 8 bar.

Ø of solids 2 mm.

Water temperature from 4 °C to 35 °C.

Maximum start-ups: 30/hour.

Vertical or horizontal installation.

Acuaplus N Pressure

Submersible multistage pump with variable speed

Equipment

Multistage submersible pump with

electronic variable speed regulation

and integrated pressure sensor for

constant pressure.

Incorporating a detection and protection

device against functioning in dry

operation, with sequential start-up

attempts in the event of failure.

Reduces the water hammer effect on the

installation. Oil chamber with double

mechanical seal.

You must install a pressure vessel on the

discharge pipework minimum 18 ltrs.

Electronics

Advanced ESPA Speed Drive technology,

enabling variable speed operation,

with automatic self-regulation which

maintains the constant pressure

required at all times in the home,

thanks to its pressure sensor.

Model

Acuaplus N

[Kg]

11.5

A

517

F

175

E

254

D

170

C

1”126

B

D

F

E

A

B

C

Performance curves at 2900 rpm (similar to acuaria 07/4)

Hydraulic performance table

Dimensions and weights

I [A]

1~

230 V

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]c

[μF] m3/h

l/min

4,7 1 0.75 1 12 mwc 40 40 40 34,6 25,3 16,1

0

0

0.6

10

1.2

20

2.4 3

40 50

1.8

30

Acuaplus N 5M

The pump can operate atv any point inside the indicated area. The characteristic

curves depend on the delivery pressure. By way of example, the curves are

shown for delivery pressures of 150, 200 and 300 kPa. The operating limit curve

corresponds to the maximum rotating speed.

145

Page 146: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

181

Aquabox Building Services

Compact storage tank and pressurisation unit (with air gap)

Model: Aquabox 350 Acuaplus N

Incorporating the reliable advanced electronic

Espa speed driver, which enables the

submersible pump to operate at variable

speeds while automatically regulating itself

to maintain constant pressure according

to needs. Besides saving energy, this

technological innovation makes minimal noise

and provides remarkable regularity in the

water supply flow.

Model: Aquabox 350 Acuapres

Automatic pressurisation system incorporating

the submersible Acuapres pump with built-in

pressure control.

With Variable Speed Pump

An advanced technology option: maximum

pressure control convenience, low noise

levels and considerable saving in electrical

consumption.

With Fixed Speed Pump

The most competitive, versatile and efficient

alternative for all types of buildings.

Aquabox is ESPA’s advanced solution for buildings with low pressure or volumes of flow.

It is a competitive, efficient alternative to traditional pressurisation units, eliminating the typical

fluctuations in flow, complex mechanical designs and their excessive electrical consumption.

Aquabox is a compact, well proportioned pressurising unit, with an integrated design and

maximum energy efficiency.

It comprises two basic elements: a latest-generation automatic ESPA pump and a storage tank.

The result of the advanced engineering of these two components combined is an innovative unit

offering high levels of convenience in water use, guaranteeing not only its permanent availability

(even when the water supply is cut off), but also strong, regular, constant pressure. The 200 ltr

tank can be used as a backup system in the event of restrictions on the use of water from the

mains. In line with regulation EN 1717, the outer casing incorporates a safety partition to

safeguard against the pollution of drinking water.

Applications

Aquabox is multi-purpose and can be used on sites with water supply problems.

Rural areas: second homes, village dwellings, rural tourism, etc.

Urban areas: housing developments, houses, commercial premises, restaurants, etc.

Ventilation

grille

Flexible hose Cover

Kit

Coupling

Tray

Overflow

connection

Pump

Drain

Tank

Float

Coupling

146

Page 147: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

182

Performance curves at 2900 rpm

Acuapres07 4

Pump options for the Aquabox unit / DimensionsA

B

C

Aquabox Building Services

Acuaplus N

Pump model

All overflow outlet has been built into the tank to safeguard against the possible contamination of drinking water in the public network, in the case of back flow, in compliance with European standard EN 1717.

Description Description

Aquabox 350 Acplus 230 50 Aquabox 350 Acuapres

Pump model

Acuaplus N 230 50 Acuapres07 4

Submersible

Surface

Constant pressure-variable speed

Automatic control

Dry operation protection

Inlet float

Overflow duct in accordance with regulation EN1717

Water supply/outlet connection

Overflow connection

Width A [mm]

Depth B [mm]

Height C [mm]

Empty tank weight [Kg]

Useful tank capacity

Working pressure [bar]

Flow at working pressure [l/min]

Installed capacity at P1 [kW]

Drain connection

Acuaplus N

X

X

X

X

X

X

3/4”

DN 50

600

600

1150

25.5

200

3

40

0.95

1/2”

Acuapres07 4

X

X

X

X

X

3/4”

DN 50

600

600

1150

25.5

200

2.5

30/45

0.6/0.95

1/2”

Pump model

147

Page 148: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

183

Performance curves at 2900 rpm

4

6

Technical features

Model

I

[A]

P1

[kW]P2 c

1~

230 V

1~

230 V[kW] [HP] [μF]

S T07.4/100AP 3.5 0.8 0.5 0.75 12

Applications

To restore system pressure when the

mains supply is insufficient, a pump

may be used. However to comply with

Water Authority Byelaws, a break tank

must be incorporated, as the pump

may not be connected directly to the

mains water supply.

The ESPA Sub-tank system has

been designed to solve this problem.

A fully automatic unit, the Sub-Tank

has a submersible stainless steel

pump with a built-in pressure control

incorporated into the break tank giving

space saving advantages in small

plant rooms. Control is provided by a

constant pressure deviceintegrated in the

submersible pump. Electronics prevent

starting without water. Installation is

straightforward, with only three

connection required.

Equipment

ST07.4/100AP start pressure 2,0 Bar.

Dimensions

ST07.4/100AP.

500 mm x 240 mm x 800 mm height.

Outlet connection 3/4’’ bspm.

Materials

100 Litre actual capacity high density.

Polyethylene break tanks (EN 13077).

WRAS approved.

Fitted with a 3/4’’ ball valve and Type

“AB” air gap, protecting incoming mains

supply from a class 5 designated risk of

contamination.

Float valve DN13 with proportional

behaviour (50L/min at 3.0Bar) with

stainless steel bowl.

Built-in pressure control starts and stops

pump automatically which supplies water

at constant pressure.

Prevents starting in the absence of water

and avoids water hammer.

Does not require any maintenance or

pre-charge.

Options

Extra pressure vessel to be installed in the

discharge pipework.

Limitations

Maximum temperature 40 °C.

Power supply 230 V / 1ph / 50 Hz.

Sub-Tank 100AP Building Services

Fixed speed booster and tank package

148

Page 149: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

184

ApplicationsTo restore system pressure when themains supply is insufficient, a pumpmay be used. However to comply withWater Authority Byelaws, a break tankmust be incorporated, as the pumpmay not be connected directly to themains water supply.The ESPA Sub-tank system hasbeen designed to solve this problem.A fully automatic unit, the Sub-Tankhas a submersible stainless steelpump with a built-in pressure controlincorporated into the break tank givingspace saving advantages in smallplant rooms. Control is provided by a constant pressure device integrated in the submersible pump. Electronics preventstarting without water. Installation isstraightforward, with only threeconnection plus power cable required.

EquipmentST07.3/100.05 complete with pressure stat 05.Adjustable start pressure between1.5 - 2.5 Bar.

DimensionsST07.3/100.05.500 mm x 240 mm x 990 mm height.Outlet connection 3/4’’ bspm.

Materials100 Litre actual capacity high density. Polyethylene break tanks (EN 13077).WRAS approved.

Fitted with a 3/4’’ ball valve and Type “AB” air gap, protecting incoming mains supply from a class 5 designated risk of contamination.

Float valve DN13 with proportional behaviour (50L/min at 3.0Bar) with stainless steel bowl.

Built-in pressure control starts and stopspump automatically which supplies waterat constant pressure.

Prevents starting in the absence of waterand avoids water hammer.

Does not require any maintenance orpre-charge.

OptionsExtra pressure vessel to be installed in the discharge pipework.

LimitationsMaximum temperature 40 °C.Power supply 230 V / 1ph / 50 Hz.

Sub-Tank 100/05 Building Services

Fixed speed booster and tank package

Performance curves at 2900 rpmTechnical features

Model

I

[A]

P1

[kW]P2 c

1~

230 V

1~

230 V[kW] [HP] [μF]

S T07.3/100.05 2.8 0.6 0.37 0.5 12

149

Page 150: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

185

Performance curves at 2900 rpm

Applications

To restore system pressure when the

mains supply is insufficient, a pump

may be used. However to comply with

Water Authority Byelaws, a break tank

must be incorporated, as the pump

may not be connected directly to the

mains water supply.

The ESPA Sub-tank system has

been designed to solve this problem.

A fully automatic unit, the Sub-Tank

has a submersible stainless steel

pump incorporated into the break tank

giving space saving advantages in small

plant rooms. Control is provided by a

constant pressure device, with a built in

pressure gauge. Electronics prevent

starting without water. Installation is

straightforward, with only three

connection required.

Dimensions

490 mm x 585 mm x 1675 mm height.

Outlet connection 1’’ bspf.

Materials

270 Ltrs capacity high density.

Polyethylene break tanks (EN 13077).

WRAS approved.

Fitted with a 3/4’’ ball valve and type “AB”

air gap, protecting incoming mains supply

from a class 5 designated risk of

contamination.

Pressure stat stars and stops pump

automatically which supplies water at

constant pressure. Prevents starting in the

absence of water and avoids water ham-

mer. Does not require any maintenance or

pre-charge.

Limitations

Start pressure 1.5 -3 Bar (adjustable).

Working pressure range: 2 - 8 Bar.

Maximum temperature 40 °C.

Maximum working pressure 10 Bar.

Noise levels are 65dB whwn filling set of

water and 60 dB when pump set is

running at 1 metre.

Power supply 230 V / 1ph / 50 Hz.

PS = Pressure switch version.

Sub-Tank 270/05 Building Services

Fixed speed booster and tank package

Technical features

ModelI [A] P1 [kW] P2 Dry Weight

[Kg]1~ 230 V 1~ 230 V [kW] [HP]

S T07.3M/270 2.8 0.6 0.37 0.5 44

S T07.4M/270 3.5 0.8 0.5 0.75 45

S T07.5M/270 4.1 1 0.75 1 46

S T07.6M/270 5 1.2 0.9 1.2 47

S T07.7M/270 5.5 1.4 1.1 1.5 48

S T17.5M/270 7.4 1.6 0.9 1.25 49

S T17.7M/270.PS 10.7 2.2 1.5 2 50

S T27.4M/270 7 1.5 0.9 1.25 52

S T27.6M/270.PS 10.8 2.2 1.5 2 53

ST07 ST17

ST27

7

5

6

4

7

6

5

4

3

150

Page 151: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

186

Applications

To restore system pressure when the

mains supply is insufficient, a pump

may be used. However to comply with

Water Authority Byelaws, a break tank

must be incorporated, as the pump

may not be connected directly to the

mains water supply. The ESPA Sub-tank

system has been designed to solve this

problem. A fully automatic unit, the

Sub-Tank has a submersible stainless

steel pump with a built-in pressure control

incorporated into the break tank giving

space saving advantages in small plant

rooms. An in-line inverter with built in

pressure transducer provides control.

Electronics prevent pump starting without

water and the digital displays online

pump operation, standby and fault status.

Installation is straightforward, with only

three connections required.

Limitations

The pressure vessel requires a pre-charge

with air 0.3 -0.5 bar below the working

pressure. This charge should be checked

and adjusted every six months.

Adjustable working pressure 2 – 8 Bar.

Maximum temperature 40 oC.

Maximum working pressure 10 Bar.

Noise levels are 65dB when filing set

of water and 60 dB when pump set is

running at 1 metre.

Power supply 230v/1ph/50hz and

400v/3ph/50hz options.

Materials

227 Litre actual capacity high density.

Polyethylene break tanks (BS 4213).

WRAS approved.

Byelaw 30 top tank fitted with 3/4’’

ball valve complying with (Byelaw

11) Type “AA & AB” air gap,

protecting incoming mains supply

from a class 5 designated risk of

contamination. (Byelaw 25)

Inverter starts and stops pump

automatically and supplies water at

a constant pressure.

Prevents starting in the absence of

water and avoids water hammer.

Inverter displays rotation frequency,

system pressure,

motor absorption & pump alarm.

5’’ submersible pump made of

stainless steel AISI 304, with

internal capacitor.

Dimensions

635 mm x 510 mm x 1750 mm height.

Outlet connection 1’’ bspf.

Sub-Tank 270.I Building Services

Fixed speed booster and tank package

Technical features

Model I [A] P1 [kW] P2 Dry Weight

[Kg]Single Phase Three Phase 1~ 230 V 3~ 230 V 3~ 400 V 1~ 230 V 3~ 400 V [kW] [HP]

ST40.08M/270.I ST40.08T/270.I 4.3 3.3 1.9 1 0.95 0.6 0.8 53

ST40.10M/270.I ST40.10T/270.I 5.7 3.8 2.2 1.25 1.18 0.75 1 54

ST40.12M/270.I ST40.12T/270.I 6.8 4.2 2.4 1.42 1.33 0.9 1.2 55

ST40.15M/270.I ST40.15T/270.I 7.3 5.2 3 1.6 1.55 1.1 1.5 56

ST80.12M/270.I ST80.12T/270.I 6.4 4 2.3 1.33 1.22 0.9 1.2 54

ST80.15M/270.I ST80.15T/270.I 7.5 5.4 3.1 1.62 1.52 1.1 1.5 55

ST80.20M/270.I ST80.20T/270.I 6.1 3.5 1.9 1.5 2 56

Performance curves at 2900 rpm

151

Page 152: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

187

Performance curves at 2900 rpm

Twin variable speed booster and tank package

Technical features

Model I [A] P1 [kW] P2 Dry Weight [Kg]

Single tank 1ph Twin tank 1ph 3~ 230 V 1~ 230 V [kW] [HP] Single Twin

ST40.08M/270.DI ST40.08T/480.DI 3.3 1 0.6 0.8 53 80

ST40.10M/270.DI ST40.10T/480.DI 3.8 1.25 0.75 1 54 81

ST40.12M/270.DI ST40.12T/480.DI 4.2 1.42 0.9 1.2 55 82

ST40.15M/270.DI ST40.15T/480.DI 5.2 1.6 1.1 1.5 56 83

ST80.12M/270.DI ST80.12T/480.DI 4 1.33 0.9 1.2 54 81

ST80.15M/270.DI ST80.15T/480.DI 5.4 1.62 1.1 1.5 55 82

ST80.20M/270.DI ST80.20T/480.DI 6.1 1.5 2 56 83

Applications

Two in-line inverters with built-in pressure

transducers

provides control.

Duty/standby or duty/assist configuration.

Limitations

The pressure vessel requires a pre-charge

with air 0.3 -0.5 Bar below the working

pressure.

This charge should be checked and

adjusted every six months.

Adjustable working pressure 2 – 8 Bar.

Maximum temperature 40 °C.

Maximum working pressure 10 Bar.

Noise levels are 65 dB when filing set

of water and 60 dB when pump set is

running at 1 metre.

Dimensions

480.DI. 1300 mm x 750 mm x 1650 mm

height.

270.DI. 650 mm x 520 mm x 1740 mm

height.

Outlet connection 11/2’’ bspf for ST40 & 2’’

bspf for ST80 models.

Three phase versions available on

request.

Materials

270 Litre actual capacity high density

polyethylene break tanks (BS 4213).

WRAS approved.

Byelaw 30 top tank fitted with 3/4’’ ball

valve(s) complying with (Byelaw 11). Type

“AA & AB” air gap, protecting incoming

mains supply from a class 5 designated

risk of contamination. (Byelaw 25).

Inverter starts and stops pump

automatically and supplies water at a

constant pressure.

Prevents starting in the absence of water

and avoids water hammer.

Inverter displays rotation frequency,

system pressure, motor absorption &

pump alarm.

5’’ submersible pump(s) made of stainless

steel AISI 304, with internal capacitor.

Sub-Tank 270/480.DI Building Services

152

Page 153: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

188

Tecno Booster Sets Building Services

Unit with a Tecnoplus 15 variable speed pump, 24 Ltr PEWB

pressure vessel, 100 Ltrs (95Ltr actual) break tank with type AB

air gap, all mounted on a steel black epoxy coated chassis with

anti vibration mounts.

Unit with a Tecnopres 25.5 fixed speed pump, 24 Ltr PEWB

pressure vessel, 240 Ltrs (227 Ltr actual) break tank with type AB

air gap all mounted on a steel black epoxy coated chassis with

anti vibration mounts.

Unit with a Tecno 25.5/ESD variable speed pump, 24 m/Ltr PEWB

pressure vessel, 240 Ltrs (227 Ltr actual) break tank with type AB

air gap, all mounted on a steel black epoxy coated chassis with

anti vibration mounts.

For pump duties please see the relevant catalogue page for each pump.

Be-spoke variable/fixed speed booster and tank package

153

Page 154: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

189

ES1000 Building Services

Open pressurisation set

Applications

Open pressurisation sets that are

designed to replace water that has been

lost through system leakage and to

maintain the system design fill pressure

in sealed & chilled water systems in

accordance with BS 7074 parts 1.2 & 3.

Options

Two pump options with Prisma

horizontal multistage pump or with

Per 50 m peripheral pump.

High & low pressure switch assembly.

High & low pressure switch assembly.

Technical features

ModelI [A] P2

Outlet CF Max Length Width Height1~ 230 V [kW]

ES1000 2.1 0.37 1/2’’ 3 Bar 600 550 450

ES1000P 3.53 0.55 1/2’’ 3.5 Bar 600 550 450

ES1000P ES1000

Performance curves at 2900 rpm

5

4

3

2

154

Page 155: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

190

Features

A simple to use controller that offers

single or twin pump control with

standard pumping requirements in a

single controller.

Many features in the unit are automatic

and parameters are pre-set to the most

common requirements.

Event logging for pump start, individual

pump runs hours counter, electrical

interruption & common alarm.

Volt free contacts for common fault, high

pressure, low pressure, pump fault &

pressure transducer.

Password protection for parameter entry.

Pressure settings in 0.1 bar increments.

Pump pulse option (2 second pulse if

inactive for 60 days).

Flood protection options.

Service reminder option (12 months).

Wall Mounted.

Single (1000) & Twin (2000) pump

options.

System quick-fill mode (Midi only).

Maximum vessel size 300 Ltr (Mini only).

4 Ltr break tank (Midi only).

Electrical Connections

The unit should be connected to 230 V

single phase supply, via a fused switched

outlet fitted with a 3 amp fuse.

Packaged units complete with vessel

available on request.

Wallpres Mini/Midi Building Services

Wall mounted pressurisation unit

Technical features

ModelPump Max. P2 FLC Connections [mm] Dimensions [mm] Weight

Quantity Pressure [kW] [Amps] System Mains Supply Drain Width Depth Height [kg]

Wallpres Mini 1000 1 3.0 0.035 0.3 15 (1/2’’) 15 (1/2’’) 22 245 155 485 7

Wallpres Mini 2000 2 3.0 0.035 0.3 15 (1/2’’) 15 (1/2’’) 22 245 155 485 8

Wallpres Midi 1000 1 2.5 0.37 2.6 15 (1/2’’) 15 (1/2’’) 22 240 230 485 14

Wallpres Midi 2000 2 2.5 0.37 x2 2.6 x2 15 (1/2’’) 15 (1/2’’) 22 360 240 485 19

155

Page 156: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

191

Features

Set point and differential can be adjusted

with an accuracy of 0.1 bar. High pressure

and Low pressure alarms can be set with

an accuracy of 0.1 bar. Alarm relay and

onboard buzzer, with auto reset. Dry run

protection with auto reset. (Low level

switch). Flood protection-Maximum pump

run timer can be set in increments of 10

minutes up to 990 minutes and 0 to

disable function. Single or dual pump,

configurable in the parameters. Auto

change over on dual pump setting. Pump

current monitoring will detect a fault

(excess current) and will isolate the pump

and sound alarm. On dual pump versions

it will automatically activate the second

pump until the process is complete.

Continuous pressure displayed on screen.

Hours run for each pump. Log of number

of alarms. Alarm messages displayed on

screen. Internal buzzer with mute and

reset. Activation delay to stop false starts.

Common alarm volt free or powered

output . Switch able between N/O or N/C.

3 digit high visibility LED display.

Intelligent overrun on pump to prevent

repetitive starts and guarantee set point is

achieved. 60 Day pulse of pump to

prevent seizing and flush pump. Keypad

lock function to prevent tampering. Safe

low voltage user interface. CE and EMC

approved.Proven reliable technology.

Applications

ESPA Pressurisation equipment

automatically controls the pressure in a

sealed system delivering water at a pre

determined pressure.

Once the system has been filed the

ESPRES will take over and maintain

the optimum system conditions.

Should a loss of water occur in the

system, for any reason, the built

in electronic pressure sensor will detect

the drop in pressure and automatically

start the pump restoring the system to

the original cold fill pressure.

All units incorporate dry run protection.

If the supply tank should run dry the

pump will automatically stop,

preventing serious damage.

Espres Delux versions have

additional volt free contacts:

Common fault.

High pressure.

Low pressure.

Pump fault.

Pressure transducer.

Espres/Espres Delux Building Services

Floor mounted pressurisation unit

C F 5 BarC F 3.5 Bar

Performance curves at 2900 rpm Performance curves at 2900 rpm

Technical features

ModelI [A] P2

Outlet CF Max Length Width Height Weight1~ 230 V [kW]

Espres 1000F/Espres 1000F Delux 2.3 0.37 1/2’’ 3.5 Bar 310 470 790 30

Espres 2000F/Espres 2000F Delux 2.3 2x 0.37 1/2’’ 3.5 Bar 310 470 790 38

Espres 1000FH/Espres 1000FH Delux 3.4 0.5 1/2’’ 5 Bar 310 470 790 32

Espres 2000FH/Espres 2000FH Delux 3.4 2x 0.5 1/2’’ 5 Bar 310 470 790 44

156

Page 157: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

192

Applications

Compact, totally enclosed digital

pressurisation units with pressure

transducers and a user friendly

microprocessors for use on the two

sealed systems in order to provide a

minimum system pressure requirement

to each application.

Instalation

The Espres Delux Twin system unit

should be connected to the system at

the same point as the expansion vessel

to provide a neutral pressure reading.

Options

Flood protection.

Pump pulse.

Service reminder.

Features

System quick fill mode.

Password protection for parameter entry.

Pressure settings in 0.1 bar increments.

Event logging for pump start, pump run

hours counter, electrical interruption &

common alarm.

Volt free contacts for common fault, high

pressure, low pressure, pump fault and

pressure transducer.

Espres Delux Twin System Building Services

Floor mounted pressurisation unit

Technical specifications

Espres Delux Twin System

Order code Espres Delux Twin System

Pump quantity 2

Maximum delivery pressure 2.5 bar (g)

Maximum working pressure 10 bar (g)

Electricalr requirements 230 V, 50 Hz, 1 phase

Power consumption 2x 0.37 kW

Full load current 2x 2.5 a

Noise output < 75 dBA

Break tank capacity 18 Litres

Fluid category protection 5 AB Weir overflow air gap

Model System Mains supply Drain Widht Depth Height [Kg]

Espres Delux Twin System 2x 15 (1/2’’) 15 (1/2’’) 22 470 320 800 28

Dimensions and weights

157

Page 158: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

193

Applications

Compact, totally enclosed digital

pressurisation units with vacuum

degasser for use sealed systems in

order to provide a minimum system

pressure requirement and effective

dissolved gas removal.

Instalation

The Espres Delux Plus unit should be

connected to the system at the same

point as the expansion vessel to provide

a neutral pressure reading.

The two system connections must

be installed on the return header to

the heat exchanger approx 0.5 m apart.

Options

Flood protection.

Pump pulse.

Service reminder.

Features

System quick fill mode.

Password protection for parameter entry.

Pressure settings in 0.1 bar increments.

Event logging for pump start, pump run

hours counter, electrical interruption &

common alarm.

Volt free contacts for common fault, high

pressure, low pressure, pump fault and

pressure transducer.

Individual controllers for pressurisation

and degassing function.

Vacuum degassing, turbo and normal

Interval modes.

Espres Delux Plus 150D Building Services

Wall mounted pressurisation units with vacuum degasser

Technical specifications

Espres Delux Plus 150D

Maximum system volume 50.000 litres

Working pressure range 1 - 5 bar (g)

System temperature range 0 - 90 °C

Ambient temperature range 0 - 45 °C

Noise rating Approx. 75 dB(A)

Electrical requirements 230 V / 50 Hz

Full load current 3.4 amps

Power used 0.5 kW

Fuse rating 13 amps

Model System Mains supply Overflow Widht Depth Height [Kg]

Espress Delux Plus 150 D 2x 15 (1/2’’) 15 (1/2’’) 22 410 290 485 22

Dimensions and weights

Espres Delux Plus 150D

Safety rating IP 54

Maximum turbo rutine 168 hours (1 week)

Maximum normal downtime 180 minutes (3 hours)

Control interface RS 485

Volt free contacts Common fault contact

Maximum delivery pressure 5 bar(g) Cold fill

Maximum working pressure 10 bar(g)

Break tank capacity 4 Litres

Fluid category protection 5 AB Weir overflow air gap

158

Page 159: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

194

Applications

Compact, totally enclosed digital

pressurisation units with vacuum

degasser for use sealed systems in

order to provide a minimum system

pressure requirement and effective

dissolved gas removal.

Instalation

The Espres Delux Plus unit should be

connected to the system at the same

point as the expansion vessel to provide

a neutral pressure reading.

The two system connections must be

installed on the return header to the heat

exchanger approx 0.5 m apart.

Options

Flood protection.

Pump pulse.

Service reminder.

Features

System quick fill mode.

Password protection for parameter entry.

Pressure settings in 0.1 bar increments.

Event logging for pump start, pump run

hours counter, electrical interruption &

common alarm.

Volt free contacts for common fault, high

pressure, low pressure, pump fault and

pressure transducer.

Individual controllers for pressurisation

and degassing function.

Vacuum degassing, turbo and normal

Interval modes.

Espres Deluxe Plus 250/280D Building Services

Floor and wall mounted pressurisation units with vacuum degasser

Technical specifications

Espres Delux Plus 250 D

Maximum system volume 300.000 Litres

Working pressure range 1 - 6 bar(g)

System temperature range 0 - 90 °C

Ambient temperature range 0 - 45 °C

Noise rating Approx. 75 dB(A)

Electrical requirements 1x 230 V / 50 Hz

Full load current 2x 3.4 amps

Power used 2x 0.5 kW

Fuse rating 13 amps

Safety rating IP 54

Maximum turbo rutine 168 hours (1 week)

Maximum normal downtime 180 minutes (3 hours)

Control interface RS 485

Volt free contacts Common fault contact

Maximum delivery pressure 6 bar(g) Cold fil

Maximum working pressure 10 bar(g)

Break tank capacity 18 Litres

Fluid category protection 5 AB Weir overflow air gap

Espres Delux Plus 280D

Maximum system volume 300.000 litres

Working pressure range 1 - 8 bar (g)

System temperature range 0 - 90 °C

Ambient temperature range 0 - 45 °C

Noise rating Approx. 75 dB(A)

Electrical requirements 1x 230 V / 50 Hz

Full load current 2x 5.6 amps

Power used 2x 0.75 kW

Fuse rating 13 amps

Safety rating IP 54

Maximum turbo rutine 168 hours (1 week)

Maximum normal downtime 180 minutes (3 hours)

Control interface RS 485

Volt free contacts Common fault contact

Maximum delivery pressure 8 bar(g) Cold fill

Maximum working pressure 10 bar(g)

Break tank capacity 18 Litres

Fluid category protection 5 AB Weir overflow air gap

Model System Mains supply Overflow Widht Depth Height [Kg]

Espres Delux Plus 250D 2x 15 (1/2’’) 15 (1/2’’) 22 480 330 1160 51

Espres Delux Plus 280D 2x 15 (1/2’’) 15 (1/2’’) 22 600 330 1160 61

Dimensions and weights

159

Page 160: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

195

Applications

The Espresmat balanced pressure

expansion units are sized according to

the total system volume and the boiler/

chiller load. The Espresmat vessel is

80% efficient irrespective of the static

height of the system. It is ideal solution

for large/tall installations where

standard membrane expansion vessels

are limited.

Description

The Espresmat is an advanced product

that combines a balanced pressure

system with an effective pressure step

de-aerator function and an inter-link

to a top up pressurisation unit.

The real time LCD display shows the

status of the mechanical components

while monitoring the vessel contents

and the system pressure.

Features

On/Off switch with indicator neon.

WRAS approved break tank.

WRAS approved float valve.

AB air gap with weir overflow,

fluid category 5.

Pump 230 V / 1ph / 50Hz.

Electronic pressure transducer.

Normally closed, common fault

volt free boiler interlock.

Normally open high pressure,

low pressure, transducer health

and pump health volt free contacts.

System jogging.

Easy setup and commissioning.

Espresmat Building Services

Floor mounted pressurisation unit

8.587.576.565.554.543.532.521.510.50 Flow Rate [m3/h]

Power Fload [MW]9876543210

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

PN 16

PN 10

PN 6

Field of application at 2900 rpm

Curves obtained in accordance with ISO9906, appendix A

160

Page 161: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

196

CKE Booster sets Building Services

Economical variable speed sets (CKE)

Applications

A range of variable speed booster sets

for commercial and domestic

applications.

Materials

Stainless steel AISI 304 manifolds.

WRAS approved pumps.

WRAS approved valves.

WRAS approved pressure vessel with

5 year warranty.

Steel chassis finished in Black epoxy

coating.

Glycerine filled pressure gauge.

Stainless steel pressure transducer

4-20 ma.

Features

An innovative system that can be with

vertical or horizontal pumps.

Saves energy up to 50%.

Quiet running and small footprint.

Interface is user friendly allowing easy

use to calibrate pressure set points,

view error messages.

Multipunp capability one to four pumps.

Control box housing motor mcb’s,

common volt free contact and low water

contacts for break tank float switch.

ErP Compliant.

Field of application at 2900 rpm

Curves obtained in accordance with ISO9906, appendix A

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE2M TEC15.5T11-24 0.75 60 54

CKE2M TEC25.5T11-24 1.1 240 55

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE2 TEC15.5T11-24 0.75 60 54

CKE2 TEC25.5T11-24 1.1 240 55

Technical specifications

Single pump sets (400 V/3 PH/50 Hz)

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE1 TEC15.5T11-24 0.75 60 54

CKE1 TEC25.5T11-24 1.1 240 55

Twin pump sets (400 V/3 PH/50 Hz)

Single pump sets (230 V/1 PH/50 Hz)

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE1M TEC15.5T11-24 0.75 60 54

CKE1M TEC25.5T11-24 1.1 240 55

Twin pump sets (230 V/1 PH/50 Hz)

161

Page 162: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

197

CKE Booster sets Building Services

Technical specifications

Single pump sets (230 V/1 PH/50 Hz)

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE1M VX309F07T-24 0.75 80 60

CKE1M VX313F11T-24 1.1 80 88

CKE1M VX317F15T-24 1.5 80 112

CKE1M VX505F07T-24 0.7 140 36

CKE1M VX508F11T-24 1.1 140 58

CKE1M VX510F15T-24 1.5 140 71

CKE1M VX1004F15T-24 1.5 220 40

Single pump sets (400 V/3 PH/50 Hz)

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE1 VX309F07T-24 0.75 80 60

CKE1 VX313F11T-24 1.1 80 88

CKE1 VX317F15T-24 1.5 80 112

CKE1 VX505F07T-24 0.75 140 36

CKE1 VX508F11T-24 1.1 140 58

CKE1 VX510F15T-24 1.5 140 71

CKE1 VX516F22T-24 2.2 140 115

CKE1 VX1004F15T-24 1.5 220 40

CKE1 VX1006F22T-24 2.2 220 61

CKE1 VX1009F30T-24 3 220 91

CKE1 VX1012F40T-24 4 220 123

CKE1 VX1503F30T-48 3 400 42

CKE1 VX1504F40T-48 4 400 56

Twin pump sets (230 V/1 PH/50 Hz)

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE2M VX309F07T-24 0.75 160 60

CKE2M VX313F11T-24 1.1 160 88

CKE2M VX317F15T-24 1.5 160 112

CKE2M VX505F07T-24 0.7 280 36

CKE2M VX508F11T-24 1.1 280 58

CKE2M VX510F15T-24 1.5 280 71

CKE2M VX1003F11T-24 1.1 440 30

CKE2M VX1004F15T-24 1.5 400 40

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE2 VX309F07T-24 0.75 160 60

CKE2 VX313F11T-24 1.1 160 88

CKE2 VX317F15T-24 1.5 160 112

CKE2 VX505F07T-24 0.75 280 36

CKE2 VX508F11T-24 1.1 280 58

CKE2 VX510F15T-24 1.5 280 71

CKE2 VX516F22T-24 2.2 280 115

CKE2 VX1003F11T-24 1.1 440 30

CKE2 VX1004F15T-24 1.5 440 40

CKE2 VX1006F22T-24 2.2 440 61

CKE2 VX1009F30T-24 3 440 91

CKE2 VX1012F40T-24 4 440 123

CKE2 VX1503F30T-48 3 800 42

CKE2 VX1504F40T-48 4 800 56

Twin pump sets (400 V/3 PH/50 Hz)

Triple pump sets (230 V/1 PH/50 Hz)

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE3M VX309F07T-24 0.75 240 60

CKE3M VX313F11T-24 1.1 240 88

CKE3M VX317F15T-24 1.5 240 112

CKE3M VX505F07T-24 0.75 420 36

CKE3M VX508F11T-24 1.1 420 58

CKE3M VX510F15T-24 1.5 420 71

CKE3M VX1003F11T-24 1.1 660 30

CKE3M VX1004F15T-24 1.5 660 40

ModelP2

[kW]

Max flow

rate l/min

Max

head mtrs

CKE3 VX309F07T-24 0.75 240 60

CKE3 VX313F11T-24 1.1 240 88

CKE3 VX317F15T-24 1.5 240 112

CKE3 VX505F07T-24 0.75 420 36

CKE3 VX508F11T-24 1.1 420 58

CKE3 VX510F15T-24 1.5 420 71

CKE3 VX516F22T-24 2.2 420 115

CKE3 VX1003F11T-24 1.1 660 30

CKE3 VX1004F15T-24 1.5 660 40

CKE3 VX1006F22T-24 2.2 660 61

CKE3 VX1009F30T-24 3 660 91

CKE3 VX1012F40T-24 4 660 123

CKE3 VX1503F30T-48 3 1200 42

CKE3 VX1504F40T-48 4 1200 56

Triple pump sets (400 V/3 PH/50 Hz)

Other models and CKE4 four pump sets available on request

162

Page 163: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

198

Cat 5 Booster sets Building Services

Packaged pump sets Building Services

Economical variable speed sets (CKE) with break tanks

Be-spoke packaged pump sets

Motor mounted Inverter controlled booster sets with break

tank and support frame. Fully automatic variable speed

units, for commercial and domestic applications. ErP

compliant.

Twin pump package set for heating

boilers.

Four pump set with special

pipework arrangement with variable

speed control panels.

Standard range with twin or triple

variable speed pumps with either

750/1000/1500 or 2000 Ltr break tanks

Other sizes and pump arrangements on request.

163

Page 164: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

199

Auxiliary input for low water via probe

in suction manifold.

Volt-free contacts for BMS output.

Full documentation is provided with

each booster set.

ESPA Control Panel advantages

Major feature – Every time power to the

booster set is interrupted, on resumption

of power the controller cycles through

a “filling system” programme.

This eliminates pipework failure due

to hydraulic shock.

Can control up to six frequency-

controlled pumps directly via

inverter “data bus”.

Booster sets Building Services

CKA high specification variable speed

Applications

ESPA Inverter booster sets are designed

to provide an efficient solution to water

boosting applications where existing

supplies are unreliable or insufficient

to meet the demands of commerce

and industry.

ESPA variable speed booster sets

embrace the best in modern control

techniques, whilst holding true

the traditional principles of quality

engineering.

Due to the compact design, ESPA

booster sets offer a small footprint in

relation to performance. Installation is

straightforward, with site work usually

limited to connecting site pipe work

and the provision of a suitable electrical

supply.

Features

Stainless steel suction and discharge

manifolds AISI 304 – Copper (optional

steel) finished in black epoxy coating.

WRAS approved nickel-plated brass

ball valves on each pump providing

individual isolation if necessary.

Anti-vibration mounts as standard.

Steel enclosed panel IP 54,

incorporating the following features:

One or more Danfos inverter(s)

(depending on control choice).

Door interlocked isolator.

Pump controller via transducer.

Manual/Off/Auto parameter

for each pump.

Duty pump alternation by software

control.

CPA high specification fixed speed

Fixed speed booster sets

Transducer-controlled booster series.

Fully automatic units for commercial

and domestic applications.

Espa fixed-speed boosters can be built

to customer specifications providing

automatic control of multiple-phase,

single-phase and three-phase pumps,

in either Duty/Standby,

Duty/Assist and Duty/Assist/Standby.

Low cost fixed speed booster sets

available on request.

Two jockey pumps can be controlled in

variable speed or fixed speed operation.

On a large pump system – has a

“standard anti-cavitation programme”

to prevent damage occurring to pumps

on large multi-pump sets.

Pump alternation can be time of day/

week OR on hours run. Total flexibility.

Password protection.

Please ask our sales team for a quotation or

e-mail on: [email protected]

164

Page 165: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

200

Sectional Tanks

Full range of hot press moulded panels.

Designed and manufactured to

BS 280:2001, European standards

EN.13280:2001.

The wide range of panels consist of

2 m x 1 m, 1.5 m x 1 m, 1 m x 1 m, 1 m x 0.

5m and 0.5 m x 0.5 m sizes in varying

configurations for use in side, bottom and

top, which enables tank assemblies.

Up to 2 million litres capacity.

All joints & bolts are sealed with WRAS

approved materials.

Standard ball valve chambers are

supplied and fitted with reinforced ball

valve area(s).

These chambers can be pre-insulated.

Standard size 800 x 800 x 400 mm.

Other features are: Ladders, manways &

inspection hatches, maintenance dividers

and internally flanged panels.

Water GRP break tanks Building Services

One & two piece GRP break tanks

One Piece Tanks

Manufactured from top quality glass

fibre/impregnated with polyester resin.

All materials are WRAS & WRC approved.

Raised ball valve chambers are supplied

with a reinforced ball valve area (s).

These chambers can be preinsulated.

Each tank is supplied with a screen

overflow to BS 6700 whilst tanks

supplied to the requirements of

Byelaw 30 are complete with an

additional 22 mm early warning screen

having a 0.65 mm micromesh filter.

Maintenance dividers can be installed

within the tank (s) to enable maintenance

work without a complete shut down.

Capacities from 36 to 4903 Ltrs actual.

Maximum water temperature 60 °C.

Two piece Tanks

Horizontal split tanks can be made

manufactured in both standard and

custom made versions.

These tanks are used where access is

restricted and the majority are designed

to pass through standard door-ways.

General as above specification.

Capacities from 36-4903 Ltrs actual.

Maximum water temperature 60 °C.

GRP tanks are Light grey in colour

(BS10A05).

Tanks should be situated on a

continuous solid base i.e. marine

plywood, TG board, concrete and

not rely on cross bracing alone.

165

Page 166: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

201

Fire sets Building Services

Espa manufactures a complete range of

firefighting booster sets according with

the following rules.

Booster sets to feed sprinklers

EN 12845: 2003.

CEPREVEN RT2 ABA.

APSAD R5.

Models

CE: jockey pump + electric pump.

CD: jockey pump + engine driven pump.

C2E: jockey pump + electric service

pump + electric auxiliary pump.

CED: jockey pump + electric service

pump + engine driven auxiliary pump.

Fire fighting booster sets. Range overview

Booster sets to feed fire hose reels

Booster sets according with the

following rules:

EN 23-500-90.

APSAD R1.

Models

UE: jockey pump + electric pump.

UD: jockey pump + engine driven pump.

U2E: jockey pump + electric service

pump + electric auxiliary pump.

UED: jockey pump + electric service

pump + engine driven auxiliary pump.

166

Page 167: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

202

Fire sets Building Services

Components

UE

Jockey pump: Multi.

Electrical driven Service pump. Monobloc.

Control panel.

Pressure vessel 50 l.

4 pressure switches: 3 service pump + 1 jockey.

Fittings and valves.

U2E

Jockey pump: Multi.

Service and auxiliary electrical driven pump. Monobloc.

Control panel.

Pressure vessel 50 l.

7 pressure switches: 3 service pump + 3 auxiliary

pump + 1 jockey.

Fittings and valves.

64

2

10

8

0 ESPA

UD

Jockey pump: Multi.

Diesel engine driven Service pump. Monobloc.

Control panel.

Pressure vessel 50 l.

4 pressure switches: 3 service pump + 1 jockey.

Fittings and valves.

LOMBARDINI

UED

Jockey pump: Multi.

Service electrical driven pump + Diesel engine driven pump.

Control panel.

Pressure vessel 50 l.

7 pressure switches: 3 service pump + 3 auxiliary

pump + 1 jockey.

Fittings and valves.

LOMBARDINI

ESPA010

2

4

8

6

167

Page 168: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

203

Fire sets Building Services

Components

CE CD

Jockey pump: Multi.

Electrical driven Service pump.

Control panel.

Pressure vessel 50 l.

4 pressure switches: 3 service pump + 1 jockey.

Fittings and valves.

Jockey pump: Multi.

Diesel engine driven Service pump.

Control panel.

Pressure vessel 50 l.

4 pressure switches: 3 service pump + 1 jockey.

Fittings and valves.

C2E CED

Jockey pump: Multi.

Service and auxiliary electrical driven pump.

Control panel.

Pressure vessel 50 l.

7 pressure switches: 3 service pump + 3 auxiliary

pump + 1 jockey.

2 control panel.

Fittings and valves.

Jockey pump: Multi.

Service electrical driven pump + Diesel engine driven pump.

2 control panel for engine driven pump and control panel for

electric pump.

Pressure vessel 50 l.

7 pressure switches: 3 service pump + 3 auxiliary

pump + 1 jockey.

Fittings and valves.

168

Page 169: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

204

Accessories Building Services

Manifolds

Material

Stainless steel AISI 304.

AISI 316 on request.

Surface treatment

All manifolds are degreased,

pickled and electropolished.

Welded joints

Tig method without additional material.

Connections

Screwed bsp male gas or flanged PN 16.

Optional

Manifold end caps.

Manifold flange kits.

M 150/200

M 200/125

M 200/150

M 200/100

M 250/150

M 300/200

1 1/2” M

2” M

2” M

2” M

2 1/2” M

3” M

DNM

1” M

1 1/4” M

1 1/2” M

1” M

1 1/2” M

2” M

DNP

600

600

600

600

600

700

A

300

300

300

300

300

360

B

150

150

150

150

150

170

C

370

370

370

370

370

430

D

115

115

115

115

115

135

E

90

90

90

90

90

115

FModel

Discharge

DN40 1 1/2”

DN50 2”

DN65 2 1/2”

DN80 3”

DN100 4”

DN125 5”

DN150 6”

DN200 8”

48.3 mm

60.3 mm

76.1 mm

88.9 mm

114.3 mm

139.7 mm

168.3 mm

219.1 mm

1.5 mm

1.5 mm

2 mm

2 mm

3 mm

3 mm

4 mm

4 mm

25 bar

25 bar

25 bar

25 bar

25 bar

25 bar

25 bar

25 bar

Ø Thickness Max. PressureMain pipe

Other sizes from 65 mm to 200mm PN16 for two to

eight pumps available on request.

A 150/100

A 200/100

A 200/125

A 250/125

A 250/150

A 300/200

1 1/2” M

2” M

2” M

2 1/2” M

2 1/2” M

3” M

1” M

1” M

1 1/4” M

1 1/4” M

1 1/2” M

2” M

600

600

600

600

600

700

300

300

300

300

300

360

65

65

65

65

65

65

DNM DNP A B CModel

Suction

169

Page 170: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

205

Accessories Building Services

Flexible connectors (W.R.A.S Aproved)

Max workingJP20BS

350

Test

24 bar

24 bar

24 bar

24 bar

24 bar

24 bar

24 bar

24 bar

24 bar

24 bar

16 bar

16 bar

16 bar

16 bar

16 bar

16 bar

16 bar

16 bar

16 bar

16 bar

JP23VS

130

130

130

130

130

130

200

200

200

50 mm

50 mm

65 mm

80 mm

100 mm

125 mm

150 mm

200 mm

250 mm

300 mm

Model

Installed length

JP20BS: Stainless steel screwed connector c/w socket m/f.

JP23VS: Stainless steel flanged PN 16 connector tied.

Steel fanged flexibles with rubber belows available on request.

Floating level switch

The ZIN 15/10 T level regulator is a float

switch which allows the booster set to

not start when the breaktank is empty.

(Low water protection).

Pressure transducers

Series 511 stainless steel pressure

transducers c/w 1.5 m of cable and are

available in several different pressure

ranges: 0-4 bar, 0-6 bar, 0-10 bar, 0-16

bar and 0-25 bar.

Danfos stainless steal pressure

transducer c/w 1.5 m of cable with

pressure range

D06F

D06F

D06F

D06F

D06F

D06F

D15P

D15P

D15P

Model Size Material

1/2”

3/4”

1”

1 1/4”

1 1/2”

2”

50 mm

65 mm

80 mm

Brass

Brass

Brass

Brass

Brass

Brass

Cast iron

Cast iron

Cast iron

Pressure reducing valve

Brass and cast iron pressure reducing valves to reduce outlet pressure between

1.5 - 8 bar, maximum inlet pressure of 25 bar for brass and 16 bar for cast iron.

170

Page 171: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

206

RBX Surge Arrestor Building Services

Combination Surge Arrestor & Air Release valve

Applications

Dampens effect of water hammer at

pump start up.

Provides vacuum protection when the

pump stops and the riser drains.

Description

Incorporates three design features to

automatically protect building risers

under all operating conditions, surge

and water hammer phenomena.

Effective de-aeration under all pipeline

flow and operating conditions.

Ensures the least possible resistance to

the intake of air and the least possible

negative pressure within a draining riser.

Developed to provide the optimum

usable and safe performance relative to

al functions.

Installation

To be installed at the top of each riser

to protect the complete riser system

An isolating valve should be installed

to facilitate maintenance.

The riser must be chlorinated and

thoroughly flushed before surge

arrestors are fitted.

Benefits

Very low milli second reaction time span

WRAS approved.

Dimensions and weights

Model Pressure Size Max riser Ø A [mm] B [mm] C [Kg]

025RBX PN25 1’’ 200 120 335 1’’BSP 9

050RBX PN25 2’’ 400 165 395 2’’BSP 9.5

A

B

Locking Nuts

Stainless Steel AISI 304

Locating Lugs

Stainless Steel AISI 304

Top Cover

Kumbo ABS 780

Assembly Screws

Cheesehead

Stainless Steel AISI 304

Barrel Seal

Klingersil C4430

Gasket

O - Ring Seal

EPDM Rubber

Anti Shock Orifice

High Density Polyethylene

O - Ring Seat

EPDM Rubber

Barrel

Stainless Steel AISI 304L

Lower Float

High Density Polyethylene

Float Guide

Stainless Steel AISI 304

Baffer Spacer

High Density Polyethylene

Support Screw

Cheesehead

Stainless Steel AISI 304

Bias Spring

Stainless Steel AISI 304

Nuts

Stainless Steel AISI 304

Washer

Stainless Steel AISI 304

Top Float

High Density Polyethylene

Nozzle

Stainless Steel AISI 304

Nozzle Seat

Stainless Steel AISI 304

Tie Rods

Stainless Steel AISI 304

Baffle Plate

Stainless Steel AISI 304

Optional Test Cock Connection1/4’’ BSP/NPT Female

Lower Flange

Mild Steel BS 4360 Grade 43A

Fusion Bonded Epoxy Powder Coated

alternatively Stainless Steel AISI 304

Screwed BSP (ISO R7)/NPT male

Top Flange

Mild Steel BS 4360 Grade 43A

Fusion Bonded Epoxy Powder Coated

alternatively Stainless Steel AISI 304

Materials

171

Page 172: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

207

Air & Dirt separation Building Services

For Heating & Venitilation Industry

MAGVENT – An aid to system cleaning. Removal

of potentially damaging particles from hot & cold water

systems. All magnetite which flows through this unit will

be removed 100%. Sizes range between 50-450 mm

forcombined unit air (de-aerator) & dirt separator or

just dirt separator.

Fixed or demountable models.

CLEANVENT – Combines the removal of air and

dirt through a single unit. Installed at the hottest

point in the system, the CLEANVENT will eliminate

these microbubbles from heating & chilled water

systems. Will also remove dirt particles down

to 10 microns.

DOSING POTS – Are required to feed liquid chemicals

such as corrosion inhibitors into closed systems.

The DOSING POTS consist of a mild steel vessel with

inlet (return) and outlet (flow) valves, drain valve,

filling valve, steel tundish, air release valve, wall

mounting brackets and a non-return valve.

Sizes range from 3.5-25 Ltrs.

PLEASE ASK A MENBER OF OUR SALES TEAM

FOR MORE INFORMATION

172

Page 173: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

208

Glandless Circulators Building Services

MMT high efficiency ECM canned motor and permanent magnets. Variable pressure control and constant speed.

Applications

All heating systems, air condition

systems, closed loop cooling systems

and industrial circulatory systems.

Materials

Housing-Cast iron.

Impeller-Polyamide.

Shaft-Ceramics.

Ventricular wall=Stainless Steel.

Rotor Can-Stainless steel.

Description

High efficiency EMC technology.

Energy savings.

Proportional pressure control.

Constant speed.

Automatic venting.

Low noise operation.

Operation

p-Proportional pressure control

After selecting level, pump recognises the

lowest resistance of the system and

automatically adjusts it’s own strain.

p- Constant speed

After selection, pump works in three

different speeds.

Motor

With permanent magnets.

Energy index EE 0.20.

Built-in motor protection.

Control p or constant speed.

IP 44 protection.

Class F insulation.

Voltage 1~230 V, 50-60 Hz.

Optional analogue input signal 0-10 V.

Equipment

Unions (optional extra).

Limitations

Liquid temperature range +5 to +95 °C.

Water mixed with glycol, parameters must

be checked with over 20% of glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Minimum inlet pressure 0.05 bar <75 °C,

0.28 bar <90 °C.

Performance curves

NMT-/40 NMT-/60 NMT-/80

173

Page 174: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

209

Glandless Circulators Building Services

Dimensions

Model DN D2 L [mm] b1 [mm] b2 [mm] l [mm] a [mm]

NMT40 15/20/25/32 1’’/5/4’’/6/4’’/2’’ 130/180 80 48 108 27/29/32

NMT60 15/20/25/32 1’’/5/4’’/6/4’’/2’’ 130/180 80 48 108 27/29/32

NMT80 15/20/25/32 1’’/5/4’’/6/4’’/2’’ 130/180 80 48 108 27/29/32

D2

L

b1 b2

a I

DN

Technical features

Model EEI Connection DNPump lenght

[mm]N. Pressure Weight [Kg]

NMT 15/40-130 0.2 Rp 1/2” 15 130 PN 10 bar 1.9

NMT 15/60-130 0.22 Rp 1/2” 15 130 PN 10 bar 1.9

NMT 20/40-130 0.2 Rp 3/4” 20 130 PN 10 bar 2

NMT 20/60-130 0.22 Rp 3/4” 20 130 PN 10 bar 2

NMT 25/40-130 0.2 Rp 1” 25 130 PN 10 bar 2.1

NMT 25/60-130 0.22 Rp 1” 25 130 PN 10 bar 2.1

NMT 20/40-180 0.2 Rp 3/4” 20 180 PN 10 bar 2.3

NMT 20/60-180 0.22 Rp 3/4” 20 180 PN 10 bar 2.3

NMT 25/40-180 0.2 Rp 1” 25 180 PN 10 bar 2.4

NMT 25/60-180 0.22 Rp 1” 25 180 PN 10 bar 2.4

NMT 32/40-180 0.2 Rp 11/4” 32 180 PN 10 bar 2.5

NMT 32/60-180 0.22 Rp 11/4” 32 180 PN 10 bar 2.5

NMT 32/80-180 0.24 Rp 11/4” 32 180 PN 10 bar 2.5

NMT ER versions available with analogue signal 0-10 V.

174

Page 175: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

210

Glandless Circulators Building Services

MMT SMART high efficiency ECM canned motor and permanent magnets. Variable pressure control and constant speed.

Motor

With permanent magnets.

Energy index EE1 0.21.

Built-in motor protection.

Three control modes (proportional head,

constant head & constant speed).

IP 44 protection.

Class F insulation.

Voltage 1~230 V, 50-60 Hz.

Optional NMTC pump with

communication module (c).

Equipment

Unions (optional extra).

Counter flanges (optional extra).

Limitations

Liquid temperature range +5 to +95 °C.

Water mixed with glycol, parameters

must be checked with over 20% of glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Minimum inlet pressure 0.05 bar <75 °C,

0.28 bar <90 °C.

Applications

All heating systems, air condition

systems, closed loop cooling systems

and industrial circulatory systems.

Materials

Housing-Cast iron.

Impeller-PES.

Shaft-Stainless steel

Bearings-Graphite.

Ventricular wall=Stainless steel.

Rotor Can-Stainless steel.

Description

High efficiency EMC technology.

Energy savings.

LED display for control.

Proportional pressure control.

Constant speed.

Automatic venting.

Low noise operation.

Operation

Auto mode (default).

Proportional pressure control.

Constant pressure control.

Constant speed.

Night mode.

SMART 60 SMART 80

Performance curves

SMART 40

New twin pump models NMTD 32-100R

& NMTD 40-100F, check

with our sales team

for more information.

175

Page 176: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

211

Glandless Circulators Building Services

Performance curves

SMART 100 SMART 100F SMART 120F

Technical features and dimensions

Model EEI Connection DN D2 I [mm] N. Pressure Weight [Kg]

SMART 25-40/60/80 0.21 25 mm 25 6/4” 190 PN 10 bar 4

SMART 32-40/60/80 0.21 32 mm 32 2” 190 PN 10 bar 4.1

SMART C 25-40/60/80 0.21 25 mm 25 6/4” 222 PN 10 bar 4.2

SMART C 32-40/60/80 0.21 32 mm 32 2” 222 PN 10 bar 4.3

DND2

D2

117 53 I

180

176

Page 177: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

212

Glandless Circulators Building Services

Technical features and dimensions

Model EEI Connection DN h [mm] a [mm] N. Pressure Weight [Kg]

SMART 40-100F 0.21 40 mm 40 222 75 PN 10 bar 7.4

SMART 50-100F 0.21 50 mm 50 222 82.5 PN 10 bar 8.5

SMART C 40-100F 0.21 40 mm 40 222 75 PN 10 bar 7.6

SMART C 50-100F 0.21 50 mm 50 222 82.5 PN 10 bar 8.7

100

h

a I

117 DN

Technical features and dimensions

Model EEI Connection DN h [mm] I [mm] a [mm] N. Pressure Weight [Kg]

SMART 40-120F 0.21 40 mm 40 250 228 75 PN 10 bar 9

SMART C 40-120F 0.21 40 mm 50 250 260 82.5 PN 10 bar 9

H

a I

177

Page 178: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

213

Glandless Circulators Building Services

MNT LAN F high efficiency ECM canned motor and permanet magnets. Variable pressure control and constant speed

Motor

With permanent magnets.

Energy index EE1 0.21.

Built-in motor protection.

Three control modes (proportional head,

constant head & constant speed).

IP 44 protection.

Class F insulation.

Voltage 1~230 V, 50-60 Hz.

Optional NMTC pump with

communication module.

Equipment

Counter flanges (optional extra).

Limitations

Liquid temperature range +2 to +110 °C.

(with max outside temperature up to

+40 °C. Water mixed with glycol,

parameters must be checked with over

20% of glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Minimum inlet pressure 0.05 bar <75 °C,

0.28 bar <90 °C.

Applications

All heating systems, air condition

systems, closed loop cooling systems

and industrial circulatory systems.

Materials

Housing-Cast iron.

Impeller-PES.

Shaft-Stainless steel

Bearings-Graphite.

Ventricular wall=Stainless steel.

Rotor Can-Stainless steel.

Description

High efficiency EMC technology.

Energy savings.

LED display for control.

Proportional pressure control.

Constant speed.

Automatic venting.

Low noise operation.

Operation

Auto mode (default).

Proportional pressure control.

Constant pressure control.

Constant speed.

Night mode.

Performance curves

LAN 40 LAN 50

178

Page 179: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

214

Glandless Circulators Building Services

Performance curves

LAN 65 LAN 80/100

Technical features and dimensions

Model Connection DN L [mm] A [mm] B [mm] C [mm] a [mm] N. Pressure Weight [Kg]

NMT LAN 40 40 mm 40 250 189 321 65 PN 10 bar 24

NMTD LAN 40 40 mm 40 250 403 321 65 PN 10 bar 47

NMT LAN 50 50 mm 50 280 189 355 70 PN 10 bar 31

NMTD LAN 50 50 mm 50 280 403 355 70 PN 10 bar 60

NMT LAN 65 65 mm 65 340 189 369 80 PN 10 bar 36

NMTD LAN 65 65 mm 65 340 403 369 80 PN 10 bar 63

NMT LAN 80 80 mm 80 360 189 403 100 PN 6 bar 44

NMT LAN 80 80 mm 80 360 403 403 100 PN 10 bar 44

NMTD LAN 80 80 mm 80 360 189 403 100 PN 6 bar 81

NMTD LAN 80 80 mm 80 360 403 403 100 PN 10 bar 81

NMT LAN 100 100 mm 100 360 189 403 105 PN 10 bar 47

255

DNb1

b4 DN

255h

h1

a I

a

h

h/2

I

179

Page 180: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

215

Glandless Circulators Building Services

SAN high efficiency ECM canned motor and permanet magnets for domestic hot water

Motor

With permanent magnets.

Built-in motor protection.

Shaftless spherical motor with

ECM technology.

IP 44 protection.

Class F insulation.

Voltage 1~230 V, 50-60 Hz

Option with thermostat with

temperature range 20-70 °C.

Option with timer.

Equipment

Brass unions (optional extra).

Limitations

Liquid temperature range 95 °C.

Water mixed with glycol, parameters must

be checked with over 20% of glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Minimum inlet pressure 0.05 bar <75 °C,

0.28 bar <90 °C.

Applications

Domestic hot water secondary

systems.

Materials

Housing-Bronze.

Impeller-Polyamide.

Bearings-Ceramic.

Description

High efficiency EMC technology.

Energy savings.

Four possible performances:

B version with bronze housing.

BU version with bronze housing

and timer.

BTU model with bronze housing

thermostat & timer.

GT version with bronze housing

and thermostat.

Specially adapted to the

independence of lime scale.

Operation

The pump automatically adjusts the

pressure according to the system

resistance. The timer installation is

possible for selecting the starting

time of the operation and adjusting

the thermostat.

Model Connection DN Pump Lenght N. Pressure A [mm] B [mm] C [mm] Weight [Kg]

ECO SAN 15/15B 1/2’’ 15 65mm PN 10 bar 163 150 110 0.9

ECO SAN 15/15BU 1/2’’ 15 65mm PN 10 bar 163 150 110 1

ECO SAN 15/15BTU 1/2’’ 15 65mm PN 10 bar 163 150 110 1

ECO SAN 15/15BTU 1/2’’ 15 65mm PN 10 bar 163 150 110 1

Technical features and dimensions

Performance curves

0.90.750.60.450.30.150 Q [m3/h]

1

1

1.2

0.8

0.6

0.4

0.2

0

H

[m]A

118

G1/2’’

105

B

C

76

35

65 72

180

Page 181: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

216

Glandless Circulators Building Services

SAN NMT high efficiency ECM canned motor and permanet magnets for domestic hot water

Equipment

Unions (optional extra).

Limitations

Liquid temperature range +5 to +95 °C.

Water mixed with glycol, parameters must

be checked with over 20% of glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Minimum inlet pressure 0.05 bar <75 °C,

0.28 bar <90 °C.

Applications

Domestic hot water secondary

systems.

Materials

Housing-Bronze.

Impeller-Polyamide.

Shaft-Ceramics.

Ventricular wall=Stainless steel.

Rotor Can-Stainless steel.

Description

Multi speed control.

Motor

With permanent magnets.

Built-in motor protection.

IP 44 protection.

Class F insulation.

Voltage 1~230 V, 50-60 Hz.

Technical features and dimensions

Performance curves

SAN NMT 40 SAN NMT 80SAN NMT 60

Model Connection DN Pump Lenght D2 b1 [mm] b2 [mm] l [mm] a [mm] N. Pressure [Kg]

SAN NMT ECO 20/40-130 3/4’’ 20 130 mm 11/4’’ 80 48 108 29 PN 10 bar 2.1

SAN NMT ECO 25/40-130 1’’ 25 130 mm 11/2’’ 80 48 108 32 PN 10 bar 2.2

SAN NMT ECO 20/60-130 3/4’’ 20 130 mm 11/4’’ 80 48 108 29 PN 10 bar 2.1

SAN NMT ECO 25/60-130 1’’ 25 130 mm 11/2’’ 80 48 108 32 PN 10 bar 2.2

SAN NMT ECO 20/80-130 3/4’’ 20 130 mm 11/4’’ 80 48 108 29 PN 10 bar 2.1

SAN NMT ECO 25/80-130 1’’ 25 130 mm 11/2’’ 80 48 108 32 PN 10 bar 2.2

181

Page 182: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

217

Glandless Circulators Building Services

SAN NMT ECO high efficiency ECM canned motor and permanet magnets. Variable pressure control and constant speed

Motor

With permanent magnets.

Energy index EE 0.20.

Built-in motor protection.

Control p or constant speed.

IP 44 protection.

Class F insulation.

Voltage 1~230 V, 50-60 Hz.

Optional analogue input signal 0-10 V.

Equipment

Unions (optional extra).

Limitations

Liquid temperature range +5 to +95 °C.

Water mixed with glycol, parameters must

be checked with over 20% of glycol.

Pure non-explosive liquid media free

from mineral oils and without solids.

Minimum inlet pressure 0.05 bar <75 °C,

0.28 bar <90 °C.

Applications

Domestic hot water secondary

systems.

Materials

Housing-Bronze.

Impeller-Polyamide.

Shaft-Ceramics.

Ventricular wall=Stainless steel.

Rotor Can-Stainless steel.

Description

High efficiency EMC technology.

Energy savings.

Proportional pressure control.

Constant speed.

Automatic venting.

Low noise operation.

Operation

p-Proportional pressure control

After selecting level, pump

recognises the lowest resistance

of the system and automatically

adjusts it’s own strain.

p- Constant speed

After selection, pump works in three

different speeds.

SAN NMT ECO 60 SAN NMT ECO 80

Performance curves

SAN NMT ECO 40

182

Page 183: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

218

Glandless Circulators Building Services

Technical features and dimensions

Model Connection DN Pump Lenght D2 b1 [mm] b2 [mm] l [mm] a [mm] N. Pressure [Kg]

SAN NMT ECO 20/40-130 3/4’’ 20 130 mm 1 1/4’’ 80 48 108 29 PN 10 bar 2.1

SAN NMT ECO 25/40-130 1’’ 25 130 mm 1 1/2’’ 80 48 108 32 PN 10 bar 2.2

SAN NMT ECO 20/60-130 3/4’’ 20 130 mm 1 1/4’’ 80 48 108 29 PN 10 bar 2.1

SAN NMT ECO 25/60-130 1’’ 25 130 mm 1 1/2’’ 80 48 108 32 PN 10 bar 2.2

SAN NMT ECO 20/80-130 3/4’’ 20 130 mm 1 1/4’’ 80 48 108 29 PN 10 bar 2.1

SAN NMT ECO 25/80-130 1’’ 25 130 mm 1 1/2’’ 80 48 108 32 PN 10 bar 2.2

D2

L

b1 b2

a I

DNDN 20

D2

L

b1 b2

a I

DNDN 25

183

Page 184: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

219

Glandless Circulators Building Services

GHN SOL canned motor and permanet magnets for domestic solar systems

Equipment

Unions (optional extra).

Limitations

Liquid temperature range -10 to +110 °C.

Environment temperature range

0- +40 °C.

Max working pressure at 50/80/100.

Applications

Domestic solar systems.

Materials

Housing-Cast Iron.

Impeller-Polyamide/Noryl.

Shaft-Ceramics.

Ventricular wall=Stainless steel.

Rotor Can-Stainless steel.

Description

Single head glandless.

Flow range 3 – 5.5.m3/h.

Max head 7 mtr.

System pressure PN 10 bar.

Two speed.

Port to port length 130 & 180 mm.

Motor

With permanent magnets.

IP 44 protection.

Class H insulation.

Power supply 230 V / 1ph / 50Hz.

GHN SOL 60 GHN SOL 70

Performance curves

GHN SOL 40

184

Page 185: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

220

Glandless Circulators Building Services

Technical features and dimensions

D2

L

b1 b2

a I

DNDN 15

D2

L

b1 b2

a I

DNDN 25

Model Connection DN Pump Lenght N. Pressure [Kg]

GHN SOL 15/40-130 1/2’’ 15 130 mm PN 10 bar 2.1

GHN SOL 15/60-130 1/2’’ 15 130 mm PN 10 bar 2.1

GHN SOL 15/70-130 1/2’’ 15 130 mm PN 10 bar 2.3

GHN SOL 25/40-130 1’’ 25 130 mm PN 10 bar 2.3

GHN SOL 25/60-130 1’’ 25 130 mm PN 10 bar 2.3

GHN SOL 25/70-130 1’’ 25 130 mm PN 10 bar 2.4

GHN SOL 25/40-180 1’’ 25 180 mm PN 10 bar 2.6

GHN SOL 25/60-180 1’’ 25 180 mm PN 10 bar 2.6

GHN SOL 25/70-180 1’’ 25 180 mm PN 10 bar 2.7

185

Page 186: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

221

Applications

Water supply and pressure boosting,

irrigation. Circulation of hot water and

liquid refrigerants in air conditioning

systems.

Motor

Three-phase asynchronous motor.

IP 55 protection.

Class F insulation.

Standard voltage:

230/400 V 50 Hz up to 4 kW,

400/690 V 50 Hz for higher power.

FL: 2 pole motors (2900 rpm).

FL4: 4 pole motors (1450 rpm).

Efficiency IE2.

Counter flanges available on request.

FL/FL4 Building Services

Single In line electric monobloc pumps in cast iron

Materials

Pump body, shield, lantern and cover

in cast iron.

Impeller: in cast iron (stainless steel

or bronze on request at extra cost).

Shaft: AISI 420 stainless steel.

Mechanical seal: silicon carbide/

silicon carbide.

Limitations

Maximum ambient temperature: +40 °C.

Temperature of pumped liquid:

-10 °C +130 °C.

Maximum operating pressure: 10 bar.

Maximum liquid viscosity: 5 °C.

Field of application at 2900 rpm

8

10

15

20

25

30

40

50

H

[m]

FL

1.2 3 6 12 24 60 120 Q [m3/h]

Field of application at 1450 rpm

1.2

3

4

5

6

8

10

15

20

H

[m]

3 6 12 24 60 120 180 Q [m3/h]

FL4

Curves obtained in accordance with ISO9906, appendix A

186

Page 187: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

222

FL/FL4 40 Building Services

Hydraulic performance table at 2900 rpm

ModelI [A] P2 l/min 0 100 125 150 175 200 225 250 300 350 400 450 500

3~ 400 V [kW] [HP] m3/h 0 6 7.5 9 10.5 12 13.5 15 18 21 24 27 30

FL 40x100B 1.5 0.55 0.75

mw

c

12.1 11.8 11.4 11 10.5 9.9 9.3 8.6 7

FL 40x100A 1.7 0.75 1 14 13.5 13.3 13 12.5 12 11.4 10.7 9 7

FL 40x125C 1.7 0.75 1 17 15.3 14.5 13.7 12.7 11.6 10.4 9 6

FL 40x125B 2.5 1.1 1.5 21.5 20.5 20 19 18 17 15.8 14.5 11.3 7.5

FL 40x125A 3.4 1.5 2 25 24.5 24.1 23.5 22.8 22 21 19.5 16.5 13

FL 40x160C 4.4 2.2 3 29 28.5 28 27.5 26.5 25.5 24.4 23 20 15

FL 40x160B 5.9 3 4 34.2 33.5 33 32.5 32 31 30 29 26 22.5

FL 40x160A 5.9 3 4 38.5 38 37.5 37 36 35 34 33 30 26.5

FL 40x200C 7.8 4 5.5 47 47 46.5 45.8 45 44 43 42 39.5 36.3 33

FL 40x200B 10.4 5.5 7.5 55 55 54.7 54.3 53.5 53 52 51 48.5 45.7 42.3

FL 40x200A 14.2 7.5 10 62.5 62 61.5 61 60 59.2 58.2 57.3 55 52.5 49 45 40

Hydraulic performance table at 1450 rpm

ModelI [A] P2 l/min 0 40 50 75 100 125 150 175 200 225 250 300

3~ 400 V [kW] [HP] m3/h 0 2.4 3 4.5 6 7.5 9 10.5 12 13.5 15 18

FL4 40x100X 0.9 0.25 0.33

mw

c

3.7 3.65 3.6 3.45 3.3 2.9 2.5

FL4 40x125Y 0.9 0.25 0.33 4.8 4.5 4.4 4 3.5 2.95 2.2

FL4 40x125X 0.9 0.25 0.33 6.2 6.2 6.1 5.8 5.3 4.6 3.8 2.9

FL4 40x160X 1.3 0.37 0.5 9.5 9.4 9.2 8.9 8.4 7.7 6.9 5.8 4.7

F4L 40x200Y 1.8 0.75 1 13.5 13 12.8 12.4 11.9 11.3 10.6 9.8 9 8 6

FL4 40x200X 2.5 1.1 1.5 15 14.6 14.3 13.9 13.3 12.6 11.8 10.9 10 8

Dimensions and weights

ModelDNm

DNaA B C D E F G H I [Kg]

FL 40x100B 40 PN6 445 90 355 184 77 107 260 140 120 16

FL 40x100A 40 PN6 445 90 355 184 77 107 260 140 120 16

FL 40x125C 40 PN16 425 100 325 200 93 107 300 160 140 24

FL 40x125B 40 PN16 445 100 345 211 93 118 300 160 140 25

FL 40x125A 40 PN16 445 100 345 211 93 118 300 160 140 26

FL 40x160C 40 PN16 445 100 345 226 108 118 320 170 150 30

FL 40x160B 40 PN16 485 100 385 257 108 149 320 170 150 35

FL 40x160A 40 PN16 485 100 385 257 108 149 320 170 150 36

FL 40x200C 40 PN16 525 100 425 286 127 159 380 200 180 50

FL 40x200B 40 PN16 535 100 435 286 127 159 380 200 180 55

FL 40x200A 40 PN16 535 100 435 286 127 159 380 200 180 55

FL4 40x100X 40 PN6 445 90 355 184 77 107 260 140 120 16

FL4 40x125Y 40 PN6 425 100 325 200 93 107 300 160 140 20

FL4 40x125X 40 PN16 425 100 325 200 93 107 300 160 140 20

FL4 40x160X 40 PN16 425 100 325 215 108 107 320 170 150 23

F4L 40x200Y 40 PN16 445 100 345 245 127 118 380 200 180 30

FL4 40x200X 40 PN16 445 100 345 245 127 118 380 200 180 31

DN a b c d e

40 PN6 80 100 130 4 14

40 PN10 88 110 150 4 18

n°d1 holes ø e

DN a b c

G

I H

F

C

F

B

D

A

187

Page 188: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

223

FL/FL4 50 Building Services

Hydraulic performance table at 2900 rpm

Hydraulic performance table at 1450 rpm

Dimensions and weights

n°d1 holes ø e

DN a b c

G

I H

F

C

F

B

D

A

ModelI [A] P2 l/min 0 250 300 350 400 450 500 600

3~ 400 V [kW] [HP] m3/h 0 15 18 21 24 27 30 36

FL 50x125C 3.4 1.5 2

mw

c

16.5 15.5 15 14.1 13 11.8 10.5 7

FL 50x125B 4.4 2.2 3 20 19 18.5 17.5 16.5 15.5 14.5 10.5

FL 50x125A 5.9 3 4 25 24.5 24 23.5 23 22 20.5 17

FL 50x160B 5.9 3 4 31 30 29 28 26.5 25 23 18

FL 50x160A 7.8 4 5.5 38 36.5 35.5 34.5 33.5 32.5 31 27

FL 50x200C 10.4 5.5 7.5 47 45.7 44.2 42.8 41.1 39.2 37 31

FL 50x200B 14.2 7.5 10 51.5 51 50 49 47.5 45 42.5 37

FL 50x200A 14.2 7.5 10 58.5 56.5 55.5 54.5 53 51 49 44

ModelI [A] P2 l/min 0 100 125 150 175 200 225 250 300 350 400

3~ 400 V [kW] [HP] m3/h 0 6 7.5 9 10.5 12 13.5 15 18 21 24

FL4 50x125Y 0.9 0.25 0.33

mw

c

4.8 4.6 4.5 4.3 4.1 3.9 3.6 3.3 2.4

FL4 50x125X 1.3 0.37 0.5 6.4 6.3 6.2 6.1 6 5.8 5.6 5.25 4.4 3

FL4 50x160X 1.6 0.55 0.75 9.2 8.8 8.6 8.3 8 7.7 7.3 6.9 5.9 4.5

F4L 50x200Y 2.5 1.1 1.5 13 12.7 12.4 12.1 11.7 11.2 10.7 10 8.6 6.8

FL4 50x200X 2.5 1.1 1.5 14.5 14.2 14 13.8 13.4 13 12.5 11.8 10.2 8.3 6

DN a b c d e

50 102 125 165 4 18

ModelDNm

DNaA B C D E F G H I [Kg]

FL 50x125C 50 455 110 345 221 103 118 320 180 140 27

FL 50x125B 50 455 110 345 221 103 118 320 180 140 28

FL 50x125A 50 495 110 385 252 103 149 320 180 140 32

FL 50x160B 50 495 110 385 262 113 149 340 180 160 32

FL 50x160A 50 535 110 425 272 113 159 340 180 160 42

FL 50x200C 50 545 110 435 290 131 159 400 220 180 56

FL 50x200B 50 545 110 435 290 131 159 400 220 180 57

FL 50x200A 50 545 110 435 290 131 159 400 220 180 64

FL4 50x125Y 50 435 110 325 210 103 107 320 180 140 21

FL4 50x125X 50 435 110 325 210 103 107 320 180 140 22

FL4 50x160X 50 435 110 325 220 113 107 340 180 160 25

F4L 50x200Y 50 495 110 385 280 131 149 400 220 180 36

FL4 50x200X 50 495 110 385 280 131 149 400 220 180 36

188

Page 189: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

224

FL/FL4 65 Building Services

Hydraulic performance table at 2900 rpm

Dimensions and weights

n°d1 holes ø e

DN a b c

G

I H

F

C

F

B

D

A

ModelI [A] P2 l/min 0 400 450 500 600 700 800 900 1000

3~ 400 V [kW] [HP] m3/h 0 24 27 30 36 42 48 54 60

FL 65x125C 4.4 2.2 3

mw

c

18.5 17 16.5 16 15 13 11 9

FL 65x125B 5.9 3 4 22.5 21 20.5 20 19 17.5 16 14 12

FL 65x125A 7.8 4 5.5 26.5 25.5 25.3 25 24 23 21.5 20 18

FL 65x160B 10.4 5.5 7.5 33 32.5 32 31.5 30.5 29.5 28 26 23.5

FL 65x160A 14.2 7.5 10 37 37 36.5 36 35 34 32.5 31 29

FL 65x200B 19.8 11 15 52 50.7 50.2 49.5 48 45.6 42.9 39.7 37

FL 65x200A 27 15 20 58.5 58 57.5 57 55 53 50 46.5 42.5

ModelDNm

DNaA B C D E F G H I [Kg]

FL 65x125C 65 485 140 345 226 108 118 360 205 155 32

FL 65x125B 65 525 140 385 257 108 149 360 205 155 39

FL 65x125A 65 565 140 425 267 108 159 360 205 155 43

FL 65x160B 65 575 140 435 281 122 159 400 220 180 54

FL 65x160A 65 680 140 540 306 122 184 400 220 180 61

FL 65x200B 65 680 140 540 320 136 184 440 240 200 70

FL 65x200A 65 680 140 540 320 136 184 440 240 200 77

FL4 65x125Y 65 465 140 325 215 108 107 360 205 155 25

FL4 65x125X 65 465 140 325 215 108 107 360 205 155 26

FL4 65x160Y 65 480 140 345 240 122 118 400 220 180 32

FL4 65x160X 65 480 140 345 240 122 118 400 220 180 33

F4L 65x200Y 65 525 140 385 285 136 149 440 240 200 38

FL4 65x200X 65 525 140 385 285 136 149 440 240 200 40

DN a b c d e

65 122 145 185 4 18

Hydraulic performance table at 1450 rpm

ModelI [A] P2 l/min 0 200 225 250 300 350 400 450 500 600 700

3~ 400 V [kW] [HP] m3/h 0 12 13.5 15 18 21 24 27 30 36 42

FL4 65x125Y 1.3 0.37 0.5

mw

c

5.4 5.2 5.1 5 4.8 4.5 4.05 3.5

FL4 65x125X 1.6 0.55 0.75 6.5 6.2 6.1 6 5.8 5.5 5.2 4.9 4.4

FL4 65x160Y 1.8 0.75 1 8.2 8.2 8.1 7.9 7.7 7.4 7 6.5 5.9 4

FL4 65x160X 2.5 1.1 1.5 9.1 9 8.9 8.8 8.6 8.4 8.1 7.7 7.2 5.5

F4L 65x200Y 2.5 1.1 1.5 12.5 12.4 12.2 12 11.5 10.8 10 9 8 5.8

FL4 65x200X 3.4 1.5 2 14.4 14.3 14.2 14.1 13.7 13 12.3 11.3 10.2 7.8 5

189

Page 190: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

225

FL/FL4 80 Building Services

Hydraulic performance table at 2900 rpm

Dimensions and weights

n°d1 holes ø e

DN a b c

G

I H

F

C

F

B

D

A

ModelI [A] P2 l/min 0 700 800 900 1000 1250 1500 1750 2000 2250

3~ 400 V [kW] [HP] m3/h 0 42 48 54 60 75 90 105 120 135

FL 80x160C 19.8 11 15

mw

c

31 30.3 30 29.5 29 26.5 24 20.5 16

FL 80x160B 27 15 20 37 36.5 36 35.2 34.5 32.7 30.1 27 23 19

FL 80x160A 27 15 20 42 40.8 40.5 40 39.4 38 35.5 33 29 24

FL 80x200D 27 15 20 44 44 43.5 43 41.5 39 35.5 31.5

FL 80x200C 33.3 18.5 25 51 50.2 49.9 49.5 48.5 46.5 43.5 39.5 35

FL 80x200B 38.6 22 30 57 57 56.5 56 55 53.5 51 47.7 42.5

Hydraulic performance table at 1450 rpm

ModelI [A] P2 l/min 0 300 350 400 450 500 600 700 800 900 1000 1100 1200

3~ 400 V [kW] [HP] m3/h 0 18 21 24 27 30 36 42 48 54 60 66 72

FL4 80x160Y 2.5 1.1 1.5

mw

c

8.7 8.6 8.5 8.4 8.3 8.2 8 7.5 6.8 6 5

FL4 80x160X 3.4 1.5 2 10.3 10.2 10.1 10 9.9 9.8 9.4 9 8.5 7.7 6.5

F4L 80x200Y 5.1 2.2 3 12.6 12.5 12.4 12.3 12.1 11.7 11.1 10.5 9.6 8.5

FL4 80x200X 6.5 3 4 15.4 15.2 15 14.6 14.3 13.6 12.8 12 11

ModelDNm

DNaA B C D E F G H I [Kg]

FL 80x160C 80 455 110 345 221 103 118 320 180 140 27

FL 80x160B 80 455 110 345 221 103 118 320 180 140 28

FL80x160A 80 495 110 385 252 103 149 320 180 140 32

FL 80x200D 80 495 110 385 262 113 149 340 180 160 32

FL 80x200C 80 535 110 425 272 113 159 340 180 160 42

FL 80x200B 80 545 110 435 290 131 159 400 220 180 56

FL4 80x160Y 80 435 110 325 210 103 107 320 180 140 21

FL4 80x160X 80 435 110 325 210 103 107 320 180 140 22

F4L 80x200Y 80 495 110 385 280 131 149 400 220 180 36

FL4 50x200X 80 495 110 385 280 131 149 400 220 180 36

DN a b c d e

80 138 160 200 4 18

190

Page 191: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

226

FL/FL4 100 Building Services

Hydraulic performance table at 2900 rpm

Dimensions and weights

n°d1 holes ø e

DN a b c

G

I H

F

C

F

B

D

A

ModelI [A] P2 l/min 0 1000 1250 1500 1750 2000 2250 2500 2750 3000 3500

3~ 400 V [kW] [HP] m3/h 0 60 75 90 105 120 135 150 165 180 210

FL 100x160D 19.8 11 15

mw

c

24.8 23.8 23.1 22 20.8 19.5 18 16.5 15

FL 100x160C 27 15 20 29.4 28.5 27.8 27 25.8 24.5 23.2 21.7 20.1 18.5

FL 100x160B 27 15 20 35 34 33.3 32.6 31.7 30.6 29.2 27.6 26 24.2

FL 100x200D 33.3 18.5 25 42 42 41 40 38.5 37 35.2 33 30.5 28

FL 100x200C 38.6 22 30 47 47 46.5 45.5 44.5 43 41.2 39 36.5 34

FL 100x200B 52.7 30 40 55.8 54.8 54 53.2 52 50.5 49 47 45 42.5 37

FL 100x200A 65 37 50 57 57 56.6 56.4 55.8 55 54 52.5 50.5 48 42

FL 100x250D 65 37 50 68.2 68 67 66 65 63.2 61 58.3 55 47

Hydraulic performance table at 1450 rpm

ModelI [A] P2 l/min 0 600 700 800 900 1000 1100 1200 1300 1500 1750 2000

3~ 400 V [kW] [HP] m3/h 0 36 42 48 54 60 66 72 78 90 105 120

FL4 100x160Y 3.4 1.5 2

mw

c

8 7.7 7.5 7.3 7 6.7 6.4 6.1 5.8 5

FL4 100x160X 5.1 2.2 3 10 9.7 9.5 9.3 9 8.8 8.5 8.2 7.9 7.1 6

FL4 100x200Y 8.5 3 4 12.8 12 11.7 11.5 11.3 11 10.5 10 9.5 8.5 7

FL4 100x200X 6.5 4 5.5 15 14.5 14.2 14 13.8 13.5 13.1 12.7 12.2 11 9 6.5

FL4 100x250Y 10.8 5.5 7.5 20 19 18.5 18 17.5 17 16 14 12

FL4 100x250X 14.4 7.5 10 23.5 22.2 21.9 21.6 21.2 20.9 20 18.5 16.8

ModelDNm

DNaA B C D E F G H I [Kg]

FL 100x160D 100 730 190 540 320 136 184 525 300 225 76

FL 100x160C 100 730 190 540 320 136 184 525 300 225 84

FL 100x160B 100 730 190 540 320 136 184 525 300 225 91

FL 100x200D 100 890 190 710 386 156 230 550 300 250 135

FL 100x200C 100 890 190 710 386 156 230 550 300 250 153

FL 100x200B 100 995 190 805 413 156 257 550 300 250 195

FL 100x200A 100 995 190 805 413 156 257 550 300 250 213

FL 100x250D 100 995 190 805 433 176 257 600 320 280 220

FL4 100x160Y 100 575 190 385 285 136 149 525 300 225 45

FL4 100x160X 100 615 190 425 295 136 159 525 300 225 50

FL4 100x200Y 100 615 190 425 315 156 159 550 300 250 66

FL4 100x200X 100 625 190 435 315 156 159 550 300 250 73

FL4 100x250Y 100 730 190 540 360 176 184 600 320 280 96

FL4 100x250X 100 730 190 540 360 176 184 600 320 280 106

DN a b c d e

100 158 180 220 8 18

FL 125 models available on request

191

Page 192: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

227

Applications

Water supply and pressure boosting,

irrigation. Circulation of hot water and

liquid refrigerants in air conditioning

systems.

Motor

Three-phase asynchronous motor.

IP 55 protection.

Class F insulation.

Standard voltage:

230/400 V 50 Hz up to 4 kW,

400/690 V 50 Hz for higher power.

FL: 2 pole motors (2900 rpm).

FL4: 4 pole motors (1450 rpm).

Efficiency IE2.

Counter flanges available on request.

FLD/FLD4 Building Services

Twin In line electric monobloc pumps in cast iron

Materials

Pump body, shield, lantern and cover

in cast iron.

Impeller: in cast iron (stainless steel

or bronze on request at extra cost).

Shaft: AISI 420 stainless steel.

Mechanical seal: silicon carbide/

silicon carbide.

Limitations

Maximum ambient temperature: +40 °C.

Temperature of pumped liquid:

-10 °C +130 °C.

Maximum operating pressure: 10 bar.

Maximum liquid viscosity: 5 °C.

Field of application at 2900 rpm

Field of application at 1450 rpm

Curves obtained in accordance with ISO9906, appendix A

FLD

40

30

25

20

15

10

8

6

H

[m]

12060241263 Q [m3/h]

120602412631.20.6 Q [m3/h]

15

10

8

6

5

4

3

2

H

[m]

FLD4

192

Page 193: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

228

FLD/FLD4 Building Services

Hydraulic performance table at 2900 rpm

FLD 40, 50, 65

ModelI [A] P2 l/min 0 100 150 200 225 225 225 225 225 225 500 600 700 800 900 1000

3~ 400 V [kW] [HP] m3/h 0 6 9 12 13.5 13.5 13.5 13.5 13.5 13.5 30 36 42 48 54 60

FLD 40x125D 1.7 0.75 1m

wc

25 12.5 10.5 8.1 6.8 5.2

FLD 40x125C 1.7 0.75 1 17 16.5 14.5 12.3 11 9.5 6

FLD 40x125B 2.5 1.1 1.5 21.5 20.5 19 17 16 15 11.5 7.5

FLD 40x125A 3.4 1.5 2 25 24.5 23.5 22 21 20 16.5 13

FLD 50x125C 3.4 1.5 2 16.8 15.5 15 14.1 13 11.8 10.5 7

FLD 50x125B 4.4 2.2 3 20 19 18.5 17.6 16.6 15.5 14.2 10.5

FLD 50x125A 5.9 3 4 25 24.5 24 23.5 23 22 20.5 17

FLD 50x160B 5.9 3 4 31 30 29 28 26.5 25 23 18

FLD 50x160A 7.8 4 5.5 38 36.5 35.6 34.6 33.5 32.3 30.7 26.5

FLD 65x160D 5.9 3 4 24 23 22.5 22 21.5 19.8 17.5 15

FLD 65x160C 7.8 4 5.5 27.5 26.5 26 25.5 24.3 22.6 20.2 18

FLD 65x160B 10.4 5.5 7.5 33 32.5 32 31.5 30.5 29.5 28 26 23.5

FLD 65x160A 14.2 7.5 10 37 37 36.5 36 35 34 32.5 31 29

FLD 80, 100

ModelI [A] P2 l/min 0 700 800 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000

3~ 400 V [kW] [HP] m3/h 0 42 48 60 75 90 105 120 135 150 165 180 195 210 225 240

FLD 80x160D 14.2 7.5 10

mw

c

26.1 25.3 24.9 23.4 20.5 17 12.7

FLD 80x160C 19.8 11 15 31 30.5 30 28.9 26.8 24 20.5 16

FLD 80x160B 27 15 20 37 36.5 36 34.5 32.5 30 27 23 19

FLD 80x160A 27 15 20 42 41 40.5 39.5 37.7 35.5 32.5 28.8 24

FLD 100x200F 27 15 20 34 33 32.2 30.7 29 26.8 24.5 22 19

FLD 100x200E 27 15 20 39 37.5 36.5 35 33 31 28.5 26

FLD 100x200D 19.8 11 15 25.3 24.5 23.5 22 20.5 18.5 16 13.5 10.5 7 3

FLD 100x200C 27 15 20 28 27.5 26.5 25.5 24 22 20 17.5 15 12 8.6 5

FLD 100x200B 27 15 20 29 28 27 25.5 23.5 21.5 19 16.5 13.8 10.8 7.5 3

FLD 100x200A 27 15 20 31 29 27.7 26 24.3 22 19.6 17.2 14.3 11.3 7.5 3.5

FLD4 80, 100

Hydraulic performance table at 1450 rpm

FLD4 40, 50, 65

ModelI [A] P2 l/min 0 40 50 75 100 125 150 175 200 225 250 300 350 400 450 500 600

3~ 400 V [kW] [HP] m3/h 0 2.4 3 4.5 6 7.5 9 10.5 12 13.5 15 18 21 24 27 30 36

FLD4 40x125Z 1.4 0.25 0.33

mw

c

4 3.7 3.6 3.15 2.6 1.9

FLD4 40x125Y 1.4 0.25 0.33 6.2 4.6 4.5 4.1 3.6 3 2.2

FLD4 40x125X 1.4 0.25 0.33 6.3 6.2 6.05 5.7 5.2 4.6 3.9 3

FLD4 50x125Y 1.4 0.25 0.33 4.8 4.6 4.5 4.3 4.1 3.9 3.6 3.3 2.4

FLD4 50x125X 2.2 0.37 0.5 6.4 6.3 6.2 6.1 6 5.8 5.5 5.2 4.4 3

FLD4 50x160X 2.7 0.55 0.75 9.2 8.8 8.6 8.3 8 7.7 7.3 6.9 5.9 4.5

FLD4 65x160Z 1.8 0.55 0.75 6.8 6.6 6.5 6.4 6.1 5.7 5.1 4.3 3.3

FLD4 65x160Y 1.8 0.75 1 8.3 8.1 8 7.9 7.7 7.4 7 6.5 5.8 4

FLD4 65x160X 2.5 1.1 1.5 9.1 9 8.9 8.8 8.6 8.4 8.1 7.7 7.1 5.5

ModelI [A] P2 l/min 0 300 350 400 450 500 600 700 800 900 1000 1100 1200 1300 1500 1750 2000

3~ 400 V [kW] [HP] m3/h 0 18 21 24 27 30 36 42 48 54 60 66 72 78 90 105 120

FLD4 80x160W 1.8 0.75 1

mw

c

6.4 6.3 6.2 6.1 5.9 5.6 4.9 4.1 3.2

FLD4 80x160Z 2.5 1.1 1.5 7.3 7.3 7.2 7.1 7 6.8 6.3 5.6 4.8 3.9

FLD4 80x160Y 2.5 1.1 1.5 8.6 8.6 8.5 8.4 8.3 8.2 7.9 7.4 6.8 6 5

FLD4 80x160X 3.4 1.5 2 10.3 10.2 10.1 10 9.9 9.8 9.45 9 8.4 7.5 6.5

FLD4 100x200W 3.4 1.5 2 8.5 8.1 7.8 7.4 7 6.5 6 5.3 4.6 3.8

FLD4 100x200Z 5.1 2.2 3 10.4 10 9.7 9.3 8.9 8.5 8 7.5 7 6

FLD4 100x200Y 6.5 3 4 12.8 12 11.8 11.6 11.3 10.9 10.5 10 9.5 8.5 7

FLD4 100x200X 8.5 4 5.5 15 14.4 14.2 14 13.8 13.5 13.1 12.7 12.2 11 9 6.5

193

Page 194: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

229

FLD/FLD4 Building Services

A

D

C

B

F

E

M

M

G

H I

A

D

C

B

F

E

M

M

G

H I

Dimensions and weights

FLD 40, 50, 65, 80, 100

FLD4 40, 50, 65, 80, 100

n°d1 holes ø e

DN a b c

DN a b c d e

40 88 110 150 4 18

50 102 125 165 4 18

65 122 145 185 4 18

80 138 160 200 8 18

100 158 180 220 8 18

ModelDNm

DNaA B C D E F G H I M [Kg]

FLD 40x125D 40 425 100 325 397 200 197 340 130 210 100 50

FLD 40x125C 40 425 100 325 397 200 197 340 130 210 100 50

FLD 40x125B 40 445 100 345 397 200 197 340 130 210 100 52

FLD 40x125A 40 445 100 345 397 200 197 340 130 210 100 54

FLD 50x125C 50 455 110 345 427 217 210 365 145 220 105 56

FLD 50x125B 50 455 110 345 427 217 210 365 145 220 105 58

FLD 50x125A 50 495 110 385 427 217 210 365 145 220 105 66

FLD 50x160B 50 535 110 425 480 245 235 410 170 240 120 86

FLD 50x160A 50 455 110 345 427 217 210 365 145 220 105 56

FLD 65x160D 65 485 130 345 543 275 268 450 180 270 140 81

FLD 65x160C 65 565 130 435 543 275 268 450 180 270 140 101

FLD 65x160B 65 670 130 540 543 275 268 450 180 270 140 125

FLD 65x160A 65 495 110 385 480 245 235 410 170 240 120 67

FLD 80x160D 80 690 150 540 550 280 270 510 205 305 135 141

FLD 80x160C 80 690 150 540 550 280 270 510 205 305 135 162

FLD 80x160B 80 690 150 540 550 280 270 510 205 305 135 175

FLD 80x160A 80 565 130 435 543 275 268 450 180 270 140 110

FLD 100x200F 100 720 180 540 670 325 345 630 240 390 165 162

FLD 100x200E 100 720 180 540 670 325 345 630 240 390 165 162

FLD 100x200D 100 720 180 540 670 325 345 630 240 390 165 162

FLD 100x200C 100 720 180 540 670 325 345 630 240 390 165 162

FLD 100x200B 100 720 180 540 670 325 345 630 240 390 165 162

FLD 100x200A 100 720 180 540 670 325 345 630 240 390 165 162

ModelDNm

DNaA B C D E F G H I M [Kg]

FLD4 40x125Z 40 425 100 325 397 200 197 340 130 210 100 41

FLD4 40x125Y 40 425 100 325 397 200 197 340 130 210 100 41

FLD4 40x125X 40 425 100 325 397 200 197 340 130 210 100 41

FLD4 50x125Y 50 435 110 325 427 217 210 365 145 220 105 44

FLD4 50x125X 50 435 110 325 427 217 210 365 145 220 105 46

FLD4 50x160X 50 435 110 325 480 245 235 410 170 240 120 52

FLD4 65x160Z 65 475 130 345 543 275 268 450 180 270 140 65

FLD4 65x160Y 65 475 130 345 543 275 268 450 180 270 140 65

FLD4 65x160X 65 475 130 345 543 275 268 450 180 270 140 67

FLD4 80x160W 80 485 150 335 550 280 270 510 205 305 135 72

FLD4 80x160Z 80 485 150 335 550 280 270 510 205 305 135 74

FLD4 80x160Y 80 535 150 335 550 280 270 510 205 305 135 79

FLD4 80x160X 80 535 150 335 550 280 270 510 205 305 135 83

FLD4 100x200W 100 535 180 355 670 325 345 630 240 390 165 110

FLD4 100x200Z 100 605 180 425 670 325 345 630 240 390 165 130

FLD4 100x200Y 100 605 180 425 670 325 345 630 240 390 165 138

FLD4 100x200X 100 615 180 425 670 325 345 630 240 390 165 150

FLD4 125 & 150 models available on request

194

Page 195: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

230

Applications

Domestic hot water circulation.

Materials

Pump housing = Bronze CuSn10Zn2.

Impeller = Noryl GFN2.

Seal = Carbon/Silicon carbide/Viton.

Housing O-ring = Nitrile.

Range

Dimensions = Threaded G ½ - G ¼ .

Max motor power = 1.5 kW.

Max capacity = 16 m3/hr.

Max head = 28 mwc.

Max temperature = -15/100 deg c

(120 °C with a bronze impeller).

Features

High efficiency, low noise, simplicity,

reliability and ease of maintenance &

servicing.

AP/AKP/AEP Series Building Services

In-line glanded bronze circulation pumps

Options

Different seal options.

Non standard surface treatment.

Motor thermal protectors,

Specail voltage.

Motor

IP 54 protection

Class F insulation.

Efficiency IE2.

2 pole & 4 pole.

Field of application at 2900 rpm

H

[m]

10

5

2

1

0.8

0.6

0.4

10543210.8 Q [m3/h]

Q [l/s]3210.80.60.40.2 4

195

Page 196: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

231

Applications

Domestic hot water circulation.

Materials

Pump housing = Bronze CuSn10Zn2.

Impeller = Noryl GFN2.

Seal = Carbon/Silicon carbide/Viton.

Housing O-ring = Nitrile.

Range

AEP = Threaded G1¼ .

LP/ALP = DN50-100.

Max motor power = 0.75kW.

Max capacity = 16 m3/hr.

Max head = 20 mwc.

Max temperature = +40 °C.

Features

Integrated SCA frequency converter

with low energy consumption.

AEP/LP/ALP Series Building Services

In-line glanded bronze c/w integrated inverter circulation pumps

Motor

IP 54 protection

Class F insulation.

Efficiency IE2.

2 pole & 4 pole.

Highly efficient with low noise.

Field of application at 2900 rpm

H

[m]

20

10

5

2

1

Q [l/s]2010521

196

Page 197: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

232

Applications

Heating and air-conditioning, booster/

transfer, heat recovery, power plant,

district heating, condensate, paper &

pulp and the chemical industry.

Seal Solutions

Standard single seal + 120 °C.

Internal flush + 150 °C.

External flush for sizes DN50-300.

External seal for sizes DN65-300 ALS.

Double seal system + 180 °C.

Materials

AL/AE/AKN/L = Grey cast iron

EN-GJL200 PN10.

ALH/LH/AKNH = Nodular cast iron

EN-GJS-400 PN16.

ALP/AEP/LP = Bronze CuPb5Sn5Zn5

PN10.

ALS/LS = Stainless steel AISI 316 PN16.

Range

Dimensions = DN 32-300.

Max motor power = 160 kW.

Max capacity = 1000 m3/hr.

Max head = 80 mwc.

Max temperature = -35/180 deg c.

AE/L/AL/AKN Series Building Services

In-line glanded circulation pumps

Available in version C/W inverter

Motor

IP 54/55 protection.

Class F insulation.

Efficiency IE2.

2 pole & 4 pole.

Features

High efficiency, low noise, simplicity,

reliability and ease of maintenance &

servicing.

Options

Enclosures IP 54, IP 55 ,IP 56.

Voltage 230 V, 400 V, 500 V,

600 V, 690 V.

Tropical protection.

Belzona molecular technology coating.

Anti-condensation heather of motor.

Atex-pumps.

TempCoat coating for sealing flange

(for liquid temperatures below 0 °C).

Painting according to customer

specifications.

The pumps are painted according to

standard SFS-EN ISO12944-5,

AY1001-FeSa21/2 , colour RAL3020.

Field of application at 2900 rpm

H

[m]

30

20

10

5

2

1

0.5

4050

40030020010050403020105 Q [m3/h]

Q [l/s]50 100403020105210.5

197

Page 198: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

233

Applications

Heating and air-conditioning, booster/

transfer, heat recovery, power plant,

district heating.

Seal Solutions

Standard single seal + 120 °C.

Internal flush + 120 °C (H).

External flush for sizes DN50-250.

Materials

T/AT = Grey cast iron EN-GJL200 PN10 or

Nodular cast iron EN-GJS-400 PN16.

Shaft = Stainless steel SS2324 (AISI 329).

Range

Dimensions = DN 32-250.

Max motor power = 110 kW.

Max capacity = 650 m3/hr.

Max head = 80 mwc.

Motor

IP 54/55 protection.

Class F insulation.

Efficiency IE2.

2 pole & 4 pole.

T/AT Series Building Services

In-line glanded twin head circulation pumps

Available in version C/W inverters

Options

Enclosures IP 54, IP 55 ,IP 56.

Voltage 230 V, 400 V, 500 V,

600 V, 690 V.

Tropical protection.

Belzona molecular technology coating.

Anti-condensation heather of motor.

Atex-pumps.

TempCoat coating for sealing flange

(for liquid temperatures below 0 °C).

Painting according to customer

specifications.

Limitations

Maximum working pressure 10 bar

Operating temperature + 120 °C.

Propylene glycol mixture no greater

than 50%.

The pumps are painted according to

standard SFS-EN ISO12944-5,

AY1001-FeSa21/2 , colour RAL3020.

Field of application at 2900 rpm

H

[m]

30

20

10

5

2

1

0.5

4050

40030020010050403020105 Q [m3/h]

Q [l/s]50 100403020105210.5

198

Page 199: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

234

Applications

AS & KN pumps are designed for

applications for clean non-aggressive

liquids including pressure boosting,

heating & primary hot water Circulation

ASP & KNP bronze pumps are more

suitable for hot water supply, oxygen and

maritime applications .

Materials

AS/KN

Pump housing & impeller = grey cast iron

EN-GJL-200.

Shaft = Stainless steel AISI 329.

Seal

= Carbon/SIC/EPDM (25mm AS).

= Carbon/ceramic/EPDM

(28mm KN).

ASP/KNP

Pump housing & impeller = bronze

CuSn10Zn2.

Shaft = Stainless steel AISI 329.

Seal

= Carbon/SIC/EPDM (25mm ASP).

= Carbon/ceramic/EPDM (28mm KNP).

Range

Dimensions = DN 32-65.

Max motor power = 15kW.

Max capacity = 100 m3/hr.

Max head = 50 mwc.

Fluid temperature = -15 to +120 °C.

Max ambient temperature = + 45 °C.

Max working pressure = 10 bar.

T/AT Series Building Services

In-line glanded twin head circulation pumps

Options

Enclosures IP 54, IP 55 ,IP 56.

Voltage 230 V, 400 V, 500 V,

600 V, 690 V.

Tropical protection.

Belzona molecular technology coating.

Anti-condensation heather of motor.

Atex-pumps.

TempCoat coating for sealing flange

(for liquid temperatures below 0 °C).

Painting according to customer

specifications.

Shaft seal for As & KN range

available in other materials.

Motor

IP 54/55 protection.

Class F insulation.

Efficiency IE2.

2 pole & 4 pole.

Features

According to EcoDesign-directive

requirements.

Field of application at 2900 rpm

H

[m]

30

20

10

5

2

1

0.5

4050

40030020010050403020105 Q [m3/h]

Q [l/s]50 100403020105210.5

199

Page 200: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

235

Applications

Accumulation of pressurised water

for all hydraulic domestic, agricultural

and industrial applications.

Features

WRAS approval for drinking water usage,

CE marked.

The EPDM variable geometry replaceable

membrane provides longer life by

eliminating membrane stress throughout

normal operational cycles.

A Schrader valve is fitted to each vessel

to provide air pressure adjustment, which

should be periodically checked.

AFE/ACS/AFOSB/AFESB Series Pressure Vessels

Accumulation of pressurised water

Options

Stainless steel vessels.

Stainless steel flange.

Fixed membrane.

Limitations

Temperature range:

3 to 500 lt (-10 to +100 °C)

750 to 4000 lt (-10 to +50 °C)

Technical features

Vertical In-Line

ModelCapacity

[Ltr]

Max Press

Bar

Working Temp

°C

Connection

BSPM

Ø

[mm]

Length

[mm]

Weight

[Kg]

ACS 3 3 10 -10 to +100 3/4’’ M 170 245 1.3

ACS 8 8 10 -10 to +100 3/4’’ M 220 305 1.8

ACS CE 18 18 10 -10 to +100 3/4’’ M 260 380 3.2

ACS CE 24 24 10 -10 to +100 1’’ M 260 490 3.6

ACS CE 24 24 10 -10 to +100 3/4’’ M 260 490 3.6

AFC/CAR CE 24 24 16 -10 to +100 3/4’’ M 265 490 7.5

AFE CE 35 35 10 -10 to +100 1’’ M 380 475 5.8

Vertical c/w legs

ModelCapacity

[Ltr]

Max Press

Bar

Working Temp

°C

Connection

BSPM

Ø

[mm]

Length

[mm]

Weight

[Kg]

AFE CE 50 50 10 -10 to +100 1’’ M 380 720 8.4

AFE CE 60 ct 60 10 -10 to +100 1’’ M 380 830 10.7

AFE/CAR CE 60 60 16 -10 to +100 1’’ M 380 830 21.5

AFE CE 80 ct 80 10 -10 to +100 1’’ M 460 760 12.2

AFE CE 100 ct 100 10 -10 to +100 1’’ M 460 880 13.5

AFE/CAR CE 100 100 16 -10 to +100 1’’ M 460 880 30.1

AFE CE 150 150 10 -10 to +100 1’’ M 510 1030 23.4

AFE CE 200 200 10 -10 to +100 11/4’’ M 590 1100 33

AFE/CAR CE 200 200 16 -10 to +100 11/4’’ M 590 1100 48.4

AFE CE 300 300 10 -10 to +100 11/4’’ M 650 1280 44.5

AFE/CAR CE 300 300 16 -10 to +100 11/4’’ M 650 1280 67

AFE CE 500 500 10 -10 to +100 11/4’’ M 750 1600 58.5

AFE/CAR CE 500 500 15 -10 to +100 11/4’’ M 750 1600 78.1

AFE CE 750 d750 750 8 -10 to +100 2’’ F 750 2045 153.5

AFE CE 1000 1000 10 -10 to +50 21/2’’ F 800 2130 183.5

AFE CE 1500 1500 10 -10 to +50 21/2’’ F 1000 2130 230.5

AFE CE 2000 2000 10 -10 to +50 DN 65 1100 2550 367

AFE CE 2500 2500 10 -10 to +50 DN 66 1100 2845 440

AFE CE 3000 3000 10 -10 to +50 DN 67 1250 2930 603

AFE CE 4000 4000 10 -10 to +50 DN 68 1450 3030 880

AFE CE 5000 5000 10 -10 to +50 DN 69 1450 3800 980

200

Page 201: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

236

AFE/ACS/AFOSB/AFESB Series Pressure Vessels

Technical features

Horizontal

ModelCapacity

[Ltr]

Max Press

Bar

Working Temp

°C

Connection

BSPM

Ø

[mm]

Length

[mm]

Weight

[Kg]

AFOSB CE 24 24 8 -10 to +100 3/4’’ M 260 485 4.7

AFOSB CE 24 24 8 -10 to +100 1’’ M 260 485 4.7

AFESB CE 60 ct 60 10 -10 to +100 1’’ M 380 690 10.4

AFESB CE 80 ct 80 10 -10 to +100 1’’ M 460 655 12.3

AFESB CE 100 ct 100 10 -10 to +100 1’’ M 460 780 14

AFESB CE 150 150 10 -10 to +100 1’’ M 510 950 23.5

AFESB CE 200 200 10 -10 to +100 11/4’’ M 590 1000 34.2

AFESB CE 300 300 10 -10 to +100 11/4’’ M 650 1150 44

AFESB CE 500 500 10 -10 to +100 11/4’’ M 750 1420 58

Replacement membranes

Vertical In-Line

ModelCapacity

[Ltr]

Max Press

Bar

Working Temp

°C

Connection

BSPM

Ø

[mm]

Length

[mm]

Weight

[Kg]

UMB-8 LX 8 25 90 1’’ M 203 313 3.5

UMB-24 LX 24 25 90 1’’ M 290 447 8.8

Vertical c/w legs

ModelCapacity

[Ltr]

Max Press

Bar

Working Temp

°C

Connection

BSPM

Ø

[mm]

Length

[mm]

Weight

[Kg]

SF 60 V 60 25 90 1’’ M 380 810 33

SF 100 V 100 25 90 1’’ M 460 990 51

SF 200 V 200 25 90 11/4’’ M 590 1120 112

SF 300 V 300 25 90 11/4’’ M 640 1230 130

SF 500 V 500 25 90 11/4’’ M 750 1550 202

SF 750 V 750 25 90 2’’ M 750 1950 328

SF 1000 V 1000 25 90 2’’ M 800 2180 344

Model Material dm Tie Rod/Hole

ACS18-24-AFOSB-24 EPDM 110 NO

AFE35 EPDM 110 NO

AFE-AFESB-60-80-100 EPDM 110 NO

AFE-AFESB-AFE/CAR-60-80-100 EPDM 110 YES

AFE-AFESB-150-200 EPDM 110 YES

AFE/CAR-200 EPDM 200 YES

AFE-AFESB-AFE/CAR-300 EPDM 200 YES

AFE-750-1000-1500 EPDM 200 YES

AFE-AFESB-AFE/CAR 500 EPDM 200 YES

Stainless steel flange.Galvanized steel flange.

With PP protection.

Tie Rod connection.

On top of vessel.

201

Page 202: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

237

Applications

Suited for a wide range of applications,

including booster systems, thermal

expansion, irrigation systems and

hydraulic hammer arresting.

Materials

Constructed of a virgin polypropylene

liner combined with an FDA approved

high grade butyl diaphragm, which is

held against the wall of the tank with a

steel clench ring.

All internal parts including the air valve

are rounded to prevent piercing of the

diaphragm.

The water connection uniquely provides

a dual water/air seal ensuring a complete

leak & maintenance free pressure vessel.

Pressure Wave Pressure Vessels

Irrigation systems and hydraulic hammer arresting

Features

Single diaphragm design.

NSF standard 61, CE/PED, WRAS, ACS,

ISO:9001.

Gost approved.

Patented stainless steel water

connection.

Virgin polypropylene liner.

Two part polyurethane, epoxy primed

paint finish.

Leak free, o-ring sealed air valve cap.

Comprehensive testing.

No maintenance.

5 Year warranty

Technical features

Vertical In-Line

ModelCapacity

[Ltr]

Max Press

Bar

Connection G

BSPM

Ø

[cm]

Length

[cm]

Weight

[Kg]

PWB 2 LX 2 10 1’’ M 12.7 18.3 1

PWB 4 LX 4 10 1’’ M 16.2 25.8 1.7

PWB 8 LX 8 10 1’’ M 20.3 31.7 2.6

PWB 12 LX 12 10 1’’ M 24.4 36.6 3.2

PWB 18 LX 18 10 1’’ M 27.9 36.8 4.3

PEWB 24 LX 24 10 1’’ M 28 36 4.5

PWB 35 LX 35 10 1’’ M 31.8 48.1 7.1

Vertical c/w base

ModelCapacity

[Ltr]

Max Press

Bar

Connection G

BSPM

Ø

[cm]

Length

[cm]

Weight

[Kg]

PWB 35 LV 35 10 1’’ M 31.8 55.5 7.5

PWB 60 LV 60 10 1’’ M 38.8 62.6 12.3

PWB 80 LV 80 10 1’’ M 38.8 79 16.7

PWB 100 LV 100 10 1’’ M 43 80.4 18.9

PWB 150 LV 150 10 1’’ M 43 107 26

Horozontal

ModelCapacity

[Ltr]

Max Press

Bar

Connection G

BSPM

Ø

[cm]

Length

[cm]

Weight

[Kg]

PWB 20 LH 20 10 1’’ M 43.9 28.9 6.1

PWB 24 LH 24 10 1’’ M 44.4 31,7 6.5

PWB 35 LH 35 10 1’’ M 48.1 35.4 7.9

PWB 60 LH 60 10 1’’ M 52.8 41.4 12.5

PWB 80 LH 80 10 1’’ M 72.4 41.4 17.5

PWB 100 LH 100 10 1’’ M 72.4 48.2 19.2

202

Page 203: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

238

Applications

Suited for a wide range of applications,

including booster systems, thermal

expansion, irrigation systems and

hydraulic hammer arresting.

Materials

Efficient and cost effective.

Designed with a patented controlled

action CAD2.

Diaphragm assembly.

Features a chlorine resistant 100% butyl

diaphragm.

With a precision moulded copolymer

polypropylene.

Liner for superior air and water

separation.

Constructed with a FDA approved high

grade butyl.

The diaphragm assembly seals water in a

true non-corrosive chamber.

Challenger Pressure Vessels

Irrigation systems and hydraulic hammer arresting

Features

Single diaphragm design.

NSF standard 61, CE/PED, WRAS, ACS,

ISO:9001.

Gost approved.

Stainless steel water connection.

Virgin polypropylene liner.

Two part polyurethane, epoxy primed

paint finish.

Leak free, o-ring sealed air valve cap.

Comprehensive testing.

No maintenance.

5 Year warranty.

Technical features

Vertical c/w base

ModelCapacity

[Ltr]

Max Press

Bar

Connection G

BSPM

Ø

[cm]

Length

[cm]

Weight

[Kg]

GCB 200LV 200 10 11/4’’ M 53.3 103.3 34.3

GCB 250LV 240 10 11/4’’ M 53.3 121.2 36.5

GCB 300LV 310 10 11/4’’ M 53.3 150 45.4

GCB 450LV 450 10 11/4’’ M 66 152.9 69.3

203

Page 204: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

239

Other Vessels Pressure Vessels

Irrigation systems and hydraulic hammer arresting

Pressure Wave vertical & horizontal pressure vessels 16 bar.

Versions with EPDM membranes.

Maximum temperature 90 °C.

Vertical range 8, 18, 24, 60, 80, & 100 litres.

Horizontal range 24.

Five year warranty.

Pressure Wave vertical & horizontal pressure vessels 25 bar.

versions with EPDM membranes.

Maximum temperature 90 °C.

Vertical range 8, 18, 24, 60, 80, & 100 litres.

Horizontal range 24.

Pressure vessels for solar system available on request.

A range of stainless steel expansion vessels in AISI 304

or AISI 316, horizontal or vertical with Butyl or EPDM

membranes.

Maximum service pressure of 14 bar, with a high

pressure 16 & 25 bar versions available on

some models.

The ranges are 2 to 500 Litres for vertical mounted and

20 to 500 litres for horizontal.

204

Page 205: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

205

Page 206: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

240

Page 207: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

241

WATERREGENERATION

Page 208: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

242

A compact automatic mains water top-up system for rainwater tanks

(tank sold separately).

With leak detection feature and pump with built in pressure controller

with dry run protection.

Direct Feed System Domestic Rainwater Harvesting

Complete domestic single pump system

Components Performance curves at 2900 rpm

Description

Calmed inlet DN125/DN100.

PF/ Patronen filter or VF1 Volume filter.

DN100 basic overflow c/w rodent barrier.

Floating pump intake c/w SS stainer and NRV.1.0m.

steel reinforced greenhose c/w all fittings to pump at 1’’ inlet.

Output home form pump; tank turret connector. Fully assembled and sealed.

1.8m pump riser, non-flexible reinforced anti bio-foul, 1’’.

25-40mm hoseclip x 2, stainless steel.

1 1/4’’ MBSP to 1’’ hosetail, thr’d’d, (hose intel/pump discharge side).

Pump riser hose connector, 1’’ MBSP-1’’ tail (discharge side).

1’’ FBSP thread to 25mm 90 deg elbow MDPE connector (discharge side).

Acuapres 4M pump c/w 15 mtrs of cable & pump base.

Top-up pump controller unit, c/w braided hose to isolation valve, solenoid valve,

alarmed controller, DNS50/40 tundish with bracket

Pump base with intake at 1 m.

Rainwater tank (By others).

6

4

Calmed inlet Overflow c/w

rodent barrier

Top-up controller unit Submersible pump

c/w floating intake

Patronen Filter VFI Volume Filter

208

Page 209: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

243

Technical specification of pump

Diameter 156 mm

Height 396 mm

Weight 11 kg

Rated output (max) 750 W

Supply voltage 230 V/ 1 ph / 50 hz

Water temperature 0° C to +40° C

Flow 7 m3/hr

Pressure 3.6 bar

Discharge 1’’ Female

Protection IP 68

Applications

Processes rain water use for domestic

properties.

Provides water for toilets, washing

machines and garden watering.

Description

The Eco 750 consists of an in-house

stainless steel console and a submerged

pump in the rainwater tank.

The in-house console is characterised

by its very compact construction.

The pump controller switches the

submerged pump on as soon as a

consumer point is opened.

The pump supplies the system even

when the length and heights conditions

are unfavourable.

The Eco 750 is a very light, compact and

fully automatic system controller for use

with rainwater.

The integrated pressure gauge displays

the operating pressure of the system.

Technical Description

Multi-stage submerged pump

with 1’’ pressure connection

and 10 mts cable.

Stainless steel support console.

Pump controller with dry running

protection integrated in the pump.

Benefits

Very light & quiet.

Compact with minimal space

required in the home.

Simple and easy installation.

ECO 750 (Garden) Domestic Rainwater Harvesting

Domestic single pump with controller

Performance curves at 2900 rpmTechnical specifications

Technical specification of controller

Width 290 mm

Height 145 mm

Depth 130 mm

Weight 3 Kg

System height (max) 15 mtrs

Suction & discharge 1’’

Protection class IP 54

60

50

40

30

20

10

0

H

[m]

6543210 Q [m3/h]

209

Page 210: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

244

Applications

Private Building Services.

Garden Irrigation.

Description

With the automatic pump, rainwater from

the rainwater tank can be transferred and

used for the header tank system.

The system is convenient and energy

efficient at only 500 W.

The submersible pump is equipped

with an automatic function that is

automatically activated for water

retrieval, once the header tank

is full, the pump will then switch off and

will not start again until the level in the

header drops below the set level.

To protect the pump against damage,

there is an integrated filter and pump

foot so as to prevent the suction of lager

debris from the rainwater tank.

The pump also has a dry run protection

safety feature, when the water level in

the rainwater tank is too low the pump

operation is automatically stopped.

If there is not enough rainwater in the

cistern or a loss in power supply the

systems runs by gravitational force only

without using energy.

The header tank comes with insulation for

frost protection and has a lid to prevent

unwanted contamination.

Technical Description

2x Floating valves.

2’’ Emergency overflow.

Ingenious snap on lid.

Insulation.

EN 1717 Type AB air gap.

Header Tank System Domestic Rainwater Harvesting

Domestic single pump and header tank

Performance curves at 2900 rpmTechnical specifications

Schematic

30

20

10

0

H

[m]

43210 Q [m3/h]

Technical specification of tank

Dimensions (WxHxD) 615 mm x 460 mm x 480 mm

Capacity 18 gallons (82 Ltrs)

Material Black polyethylene

Mainswater valve 3/4’’ male

Rainwater valve 1/2’’ male

Emergency overflow 2’’ male

Insulation Mineral wool

Technical specification of pump

Diameter 148 mm

Height 396 mm

Discharge 1’’ male

Power supply cable 10 mtrs

Max immersion depth 7 mtrs

Weight 5 Kg

Protection class IP 68

Rated output 500 W

Supply voltage 230 V/1 ph/50 hz

210

Page 211: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

245

Applications

Processes rain water use for domestic

properties.

Provides water for toilets, washing

machines and garden watering.

Description

The X-Press 10 Eco consists of an in-

house stainless steel console and a

submerged pump in the rainwater tank.

The in-house console is characterised by

its very compact construction.

The pump controller switches the

submerged pump on as soon as a consu-

mer point is opened.

The pump supplies the system even

when the length and heights conditions

are unfavourable.

A float switch monitors the level of the

rainwater tank constantly, so that if there

is too little rainwater in the tank, there is

an automatic changeover to the mains

water supply.

The X-Press 10 Eco is a very light,

compact and fully automatic system

controller for use with rainwater.

The integrated pressure gauge displays

the operating pressure of the system.

The solenoid valve and the tundish are

mounted onto the console.

Technical Description

Multi-stage submerged pump

with 1’’ pressure connection

and 10 mts cable.

Stainless steel support console.

Electric mains water supply with

solenoid, tundish and float switch

c/w 20 mts cable.

Pump controller with dry running

protection.

Benefits

Very light & quiet.

Compact with minimal space

required in the home.

Simple and easy installation.

X-Press 10 Eco Domestic Rainwater Harvesting

Domestic single pump with in-house console

Performance curves at 2900 rpmTechnical specifications

60

50

40

30

20

10

0

H

[m]

6543210 Q [m3/h]

Technical specification of controller

Width 290 mm

Height 145 mm

Depth 130 mm

Weight 3 Kg

System height (max) 15 mtrs

Suction & discharge 1’’

Protection class IP 54

Technical specification of pump

Diameter 156 mm

Height 396 mm

Weight 11 Kg

Rated output (max) 750 W

Supply voltage 230 V/1 ph/50 hz

Water temperature 0° C to +40° C

Flow 7 m3/hr

Pressure 3.6 bar

Discharge 1’’ Female

Protection class IP 68

211

Page 212: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

246

Applications

Processes rain water use for domestic

properties.

Provides water for toilets, washing

machines and

garden watering.

Description

The X-Press 10 Acuapres consists of an

in-house stainless steel console and a

submerged pump in the rainwater tank.

The in-house console is characterised by

its very compact construction. The pump

controller switches the submerged pump

on as soon as a consumer point is ope-

ned. The pump supplies the system even

when the length and heights conditions

are unfavourable. A float switch monitors

the level of the Rainwater tank constantly,

so that if there is too little rainwater in the

tank, there is an automatic changeover to

the mains water supply.

The X-Press 10 Acuapres is a very light,

compact and fully automatic system

controller for use with rainwater.

The included pressure vessel absorbs

water hammers in the pipework.

Additionally it prevents damage of

the pump by reducing the operation

frequency. The integrated pressure gauge

displays the operating pressure of the

system. The solenoid valve and the

tundish are mounted on the console.

Technical Description

Multi-stage submerged pump

with 1’’ pressure connection

and 10 mts cable.

Stainless steel support console.

Electric mains water supply with

solenoid, tundish and float switch

c/w 20 mts cable.

Pump controller with dry running

protection.

Benefits

Very light & quiet.

Compact with minimal space

required in the home.

Simple and easy installation.

X-Press 10 Acuapres Domestic Rainwater Harvesting

Domestic single pump with integrated controller

Performance curves at 2900 rpmTechnical specifications

6

4

Technical specification of controller

Width 290 mm

Height 145 mm

Depth 130 mm

Weight 3 Kg

System height (max) 15 mtrs

Suction & discharge 1’’

Protection class IP 55

Technical specification of pump

Diameter 126 mm

Height 493 mm

Weight 12.4 Kg

Rated output (max) 0.5 kW

Supply voltage 230 V/1 ph/50 hz

Water temperature 0° C to +40° C

Flow 4 m3/hr

Pressure 4.4 bar

Discharge 1’’ Female

Protection class IP 68

212

Page 213: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

247

Eco-System Domestic Rainwater Harvesting

Compact unit for automatic management of rainwater recovered in homes

Applications

Domestic Rainwater Harvesting.

Materials

High-density polyethylene tank.

Pump body and impellers in stainless

steel AISI 304.

Suction and discharge connections

in brass.

Drive shaft in AISI 420 stainless steel.

Diffusers in technopolymer.

Mechanical seal in graphite and steatite.

Joints in EPDM/NBR.

Operation

Compact unit ready for use,

“Plug & Play”.

Motorised 3-way valve for alternating

between rainwater/mains water.

With a 15 lt. mains water reserve tank

with overflow duct and separation of

mains water and rainwater in accordance

with EN 1717 and EN 13077 standards.

ESPA Aspri 15 4M with Pressdrive.

Dual suction.

Dry operation protection.

Equipment

Drinking water inlet valve.

Power socket for controlling

the 3-way valve.

Drainage pipe connection.

Level switch. Float with 20 m of cable.

Connections: rainwater - 1” M,

impulsion - 1” M, mains water - 3/8” H.

Dimensions and weights Performance curves at 2900 rpm

Hydraulic performance table

ModelI [A] P1 [kW] P2

c

[μF]

l/min 10 20 30 35 40 45 50 60

1~ 230 V 1~ 230 V [kW] [HP] m3/h 0.6 1.2 1.8 2.1 2.4 2.7 3.0 3.6

Eco-System 3.5 0.8 0.55 0.75 12 mwc 43 39 35 32 27 25 21.5 17

A

B

E

FGH

IJ

K

C

D

Model A B C D E F G H I J K

Eco-System 609 350 620 220 75 174 110 212 220 300 430

213

Page 214: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

248

Rainpres Domestic Rainwater Harvesting

To work in installations for rain water recovery

Applications

Pressurising of domestic water for

houses, semi-detached homes,

apartments, chalets and rural homes...

Materials

Outer casing, discharge body, impellers,

filter, discharge cover and motor casing

in stainless steel AISI 304.

Pump shaft in stainless steel AISI 303.

Diffusers in PPO.

Mechanical seal in graphite

and alumine/graphite/steatite/NBR/

AISI 304.

Motor

Asynchronous, two poles.

IP 68 protection.

Class F insulation.

Continuous operation.

Water-cooled motor.

Single-phase version with Klixon

(incorporated thermal protection).

Limitations

Maximum working pressure 8 bar.

Ø of solids 2 mm.

Maximum 30 start-ups per hour.

Water temperature from 4 °C to 40 °C.

Motor characteristics 230 V.

Vertical installation only.

Equipment

Submersible multistage pump with

built-in pressure control and non return

valve.

Dry running control with four trials

if no water.

Oil chamber with two mechanical seals.

Model 4: starting pressure at 2 bar.

Model 6: starting pressure at 3 bar.

You must install a pressure vessel

on the discharge pipework minimum

24 ltrs.

Equipped with a suction base, with

connection for a floating suction.

Rainpres 4

Rainpres 6

493

560

10.6

12.4

1”

1”

126

126

Model A [kg]CB

A

B

C

Performance curves at 2900 rpm

12

16

3.5

5

1.7

2

I [A]

1~

230 V

3~

400 V

Model

P1 [kW]c

[μF] m3/h

l/min

41

60

0.6

10

37

55

1.2

20

32

47

1.8

30

26

37

2.4

40

22

32

2.7

45

19

26

3.0

50

10

15

3.6

60

6

9

3.9

65

mw

c

P2

0.5

0.9

0.75

1.2

[kW] [HP]

0.8

1.2

0.8

1.1

1~

230 V

3~

400 V

Rainpres 4

Rainpres 6

Hydraulic performance table

Dimensions and weights

4

6

214

Page 215: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

249

Rain Colletor Domestic Rainwater Harvesting

Waterbutt range

Applications

A packaged rain collector c/w base,

tap and rain diverter for the garden.

Materials

Polybutts are strong, durable & available

in a choice of colours.

Manufactured from UV stabilised LLDPE

(linear low density polyethylene).

Polybutts will not degrade over time and

will retain its strength throughout a

10-15 year working life.

Available in Recycled Black, Standard

Green, Oak and washed Terracotta.

Technical specifications

ModelCapacity

[ Ltr]Diameter Lenght Widht Height

Polybutt 110 110 430 1210

Polybutt 220 220 520 1320

Triplo 700 700 1710 530 1030

Doublo 1200 1200 1603 742 1460

Prestige 1500 1500 1700 850 1620

Polybutts 100 Polybutts 200

Prestige 1500, one piece mouldingDoublo 1200, one piece mouldingTriplo 700, one piece moulding

215

Page 216: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

250

X-Press 50 Commercial Rainwater Harvesting

Twin pump rainwater system c/w submersible pumps

Applications

Private and commercial process water

consumption.

Garden irrigation up to a volume

of 14 m3/h.

Description

The X-Press 50 consists of a metal

console inside the building and two

stainless steel submersible pumps in

the rainwater tank.

The console inside the building has a

very compact design.

On the metal console are the pump

controls and a solenoid valve with funnel

for topping up with mains water.

The system controls the switch on of the

submersible pump as soon as water

begins to be consumed.

The pump will supply the system even in

situations where the length and height

conditions are unfavourable.

A float switch constantly monitors the

level of the rainwater tank so that it

automatically switches to supply

with mains water when the rainwater

level is low.

The intelligent link between the system

controls And the solenoid valve is fully

automated and Topping up with mains

water only occurs when needed.

Technical Description

Multi-stage submerged pumps

with 1 1/4’’ intake and 15 mts cable.

1 mtr floating suction.

Stainless steel manifold to connect

the two submersible pumps.

Base console made of metal with

cover.

Electrically operated mains water

top-up with solenoid valve & funnel.

Technical Description

Console: 550 x 550 x 320 mm.

Manifold inlet: 2x1’’ male.

Manifold outlet: 1 1/2’’ male.

Mains water: 1’’ male.

Mains water top-up: DN 100 adapters.

Level senor: 20 mtrs (no ground cable).

Weight: 10 Kg.

Benefits

Very quiet.

Very reliable operation.

Simple and easy installation.

Need-based topping up of mains water

in compliance with EN 1717.

Performance curves at 2900 rpmSubmersible Pumps

Technical specification

ModelMax flow rate

[m3/h]

Max head

[mtrs]

Current drain

[2x 230 V]

Motor output P1

[kW]

Pump lenght

[mm]

X-Press 50 8-40 8 42 2x 4.4 amps 2x 0.94 603

X-Press 50 8-70 8 72 2x 6.5 amps 2x 1.45 670

X-Press 50 14-50 14 51 2x 5.2 amps 2x 1.12 603

X-Press 50 14-60 14 64 2x 6.5 amps 2x 1.45 670

X-Press 50 14-70 14 77 2x 7.8 amps 2x 1.70 697

11 12 130 1 2 3 4 5 6 7 8 9 10 Q [m3/h]

8-40

14-70

14-60

14-50

8-70

70

60

40

30

20

10

0

80

50

H

[m]

216

Page 217: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

251

X-Press 100 Commercial Rainwater Harvesting

Triple pump rainwater system c/w submersible pumps

Applications

Commercial process water consumption.

Garden irrigation up to a volume

of 21m3/h.

Description

The X-Press 100 consists of a metal

console inside the building and three

stainless steel submersible pumps in

the rainwater tank.

The console inside the building has a

very compact design.

On the metal console are the pump

controls and a solenoid valve with funnel

for topping up with mains water.

The system controls the switch on of the

submersible pump as soon as water

begins to be consumed.

The pump will supply the system even in

situations where the length and height

conditions are unfavourable.

A float switch constantly monitors the

level of the rainwater tank so that it

automatically switches to supply

with mains water when the rainwater

level is low.

The intelligent link between the system

controls And the solenoid valve is fully

automated and Topping up with mains

water only occurs when needed.

Technical Description

Multi-stage submerged pumps

with 1 1/4’’ intake and 15 mts cable.

1 mtr floating suction.

Stainless steel manifold to connect

the three submersible pumps.

Base console made of metal with

cover.

Electrically operated mains water

top-up with solenoid valve & funnel.

Technical Description

Console: 550 x 550 x 320 mm.

Manifold inlet: 2x1’’ male.

Manifold outlet: 1 1/2’’ male.

Mains water: 1’’ male.

Mains water top-up: DN 100 adapters.

Level senor: 20 mtrs (no ground cable).

Weight: 10 Kg.

Benefits

Very quiet.

Very reliable operation.

Simple and easy installation.

Need-based topping up of mains water

in compliance with EN 1717.

Performance curves at 2900 rpmSubmersible Pumps

Technical specification

14-40

14-80

20-50

20-60 20-70

80

70

60

50

40

30

20

10

0

H

[m]

20191817161514131211109876543210 Q [m3/h]

ModelMax flow rate

[m3/h]

Max head

[mtrs]

Current drain

[2x 230 V]

Motor output P1

[kW]

Pump lenght

[mm]

X-Press 100 14-40 14 42 3x 4.4 amps 3x 0.94 603

X-Press 100 14-80 14 86 3x 7.8 amps 3x 1.45 697

X-Press 100 20-50 21 51 3x 5.2 amps 3x 1.12 603

X-Press 100 20-60 21 64 3x 6.5 amps 3x 1.5 670

X-Press 100 20-70 21 77 3x 7.8 amps 3x 1.8 697

217

Page 218: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

252

SP50 Commercial Rainwater Harvesting

Twin pump rainwater system c/w surface pumps

Applications

Processes rain water use for domestic

and commercial properties.

Provides rainwater for toilets, laundry

and irrigation by integrated pumps.

Volumes up to 10 m3/hr.

Description

All system processes are monitored

constantly.

This guarantees that the system is ready

for operation at any time.

The multistage self priming pumps

guarantees both quiet operation and a

convenient start-up. The pumps start up

alternately, which reduces down time.

If larger volumes have to be moved,

then the second pump is switched in for

cascaded operation. In operation the

pressure sensor provides dry running

protection and pressure controlled

disconnection for convenient handling,

the pressure is shown clearly on the

LCD display. Should there be a shortage

of rainwater, mains water is supplied

on demand until sufficient rainwater

is again available. At the same time,

a zone valve makes the changeover

controlled via a float switch in the tank.

The mains is fed in accordance with EN

1717 via a proportional float valve. For

stagnation protection the water in mains

supply is changed after a standing time

of 30 days. The change to mains water

operation can also be made manually.

All connections are designed as screw

connections, except for electrical

connection whichare plug-in.

Covers, pumps and mains water tanks

are provided with vibration protection

components. The floor mounted system

controller is easy and quick to install.

Technical Description

Polyethylene mains water break tank.

Galvanised metal console.

Polypropylene pump housing.

Multistage self priming pumps.

Electronic control.

Float switch with 20 m lead and

counter weight.

Cover.

Emergency overflow, dial 70 mm.

Vibration damper for pump and

mains water break tank.

Proportionally controlled top-up

valves.

Free discharge to EN1 717. Type AB.

Optional accesories

Supply pump for poor suction condition

(large distance between rainwater tank

System controller).

Level sensor.

Connection set.

Benefits

Fully automatic.

Simple and easy installation.

Specially developed automatic

controller.

Compact and ready for connection.

Technical specification

Description

Capacity (max) 10 m3/hr

Pressure (max) 4.8 bar

Head (max) 20 mtrs

Suction depht (max) 8 mtrs

Protection class IP 41

Rated output 2x 1000 W

Supply voltage 230 V/50 hz

Suction line 2x 1’’ female

Pressure line 11/2’’ male

Mains water connection 2x 3/4’’ male

Emergency overflow 2x 70 mm

Float switch 20 mtrs (no earth lead)

Dimensions [W x H x D] 550 x 850 x 650 mm

Weight (empty) 62 Kg

Performance curves at 2900 rpm

131211109876543210 Q [m3/h]

80

70

60

50

40

30

20

10

0

H

[m]

218

Page 219: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

253

SP75H Commercial Rainwater Harvesting

Twin pump cabinet rainwater system c/w surface pumps

Applications

Processes rain water for industrial and

commercial facilities.

Garden irrigation.

Up to a volume of 14m3/h.

Description

The SP75H system controller is a

complete rainwater system with

integrated break tank, twin and multi

stage pumps with electric controller.

It monitors the level in the catchment

and break tanks. Depending or demand,

the supply pump in the catchment tank

feeds rainwater into the SP75H’s break

tank. The integrated twin pressure

pump unit then supplies rainwater to the

points of use. If there is a shortage of

rainwater or manual changeover, the

break tank is topped up automatically,

on demand with mains water complying

with DIN EN 1717. The solenoid valve is

also checked regularly, in order to

avoid stagnant water in the mains

water line. The pressure and suction

connections can be made on the left or

right hand side. This makes the wall

clearance needed to be very small.

Technical Description

Twin pump unit, multistage,

horizontal pump with alternate

side connections.

Option to connect a second supply

pump for two cistern operation,

Maximum flow up to 14 m3/h.

Electronic controller with four.

Line LCD display.

Hours run counter for each pump.

Twin pump unit pressure indicator.

Catchment tank level gauge (optional).

Manual changeover to mains a water

mode (optional).

Zero potential fault sensor.

RS 232 interface.

Powder coated sheet steel cabinet.

Benefits

High quality, professional system

engineering.

Quick and simple installation.

Specially developed automatic

controller.

High degree of operational safety.

Pressure and suction connections on

left or right hand side.

Performance curves at 2900 rpm

Dimensions and weights

Technical specification

ModelWidht

[mm]

Height

[mm]

Depht

[mm]

Weight

(empty)

Max

weight

Pressure

line

Booster

pump

Mains

water

Header tank

volume

Emergency

overflow

SP 75H 8-40 570 1325-1335 630 90 180 11/2’’ male 11/4’’ male 11/4’’ male 100 Ltrs DN 100

SP 75H 8-60 570 1325-1355 630 90 180 11/2’’ male 11/4’’ male 11/4’’ male 100 Ltrs DN 100

SP 75H 8-70 570 1325-1355 630 90 180 11/2’’ male 11/4’’ male 11/4’’ male 100 Ltrs DN 100

SP 75H 14-40 570 1325-1355 630 100 190 11/2’’ male 11/4’’ male 11/4’’ male 100 Ltrs DN 100

SP 75H 14-60 570 1325-1335 630 100 190 11/2’’ male 11/4’’ male 11/4’’ male 100 Ltrs DN 100

ModelMax flow rate

[m3/h]

Max head

[mtrs]

Current drain

[2x 230 V]

Motor output P1

[kW]Supply voltage

SP 75H 8-40 8 42 2x 3.9 amps 2x0.8 230 V / 1 ph / 50 Hz

SP 75H 8-60 8 57 2x 5.3 amps 2x1.2 230 V / 1 ph / 50 Hz

SP 75H 8-70 8 72 2x 6,3 amps 2x1.48 230 V / 1 ph / 50 Hz

SP 75H 14-40 14 47 2x 5.3 amps 2x1.2 230 V / 1 ph / 50 Hz

SP 75H 14-60 14 59 2x 6.5 amps 2x1.48 230 V / 1 ph / 50 Hz

219

Page 220: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

254

SP100H Commercial Rainwater Harvesting

Twin pump cabinet rainwater system c/w surface pumps

Applications

Processes rain water for industrial and

commercial facilities.

Provides rainwater for toilets, laundry

and irrigation by integrated pumps.

Up to a volume of 25 m3/h.

Description

The SP 100H system controller is a

complete rainwater system with

integrated break tank, twin and multi

stage pumps with electric controller.

It monitors the level in the catchment

and break tanks. Depending on demand,

the supply pump in the catchment tank

feeds rainwater into the SP 100H’s

break tank. The integrated twin pressure

pump unit then supplies rainwater to the

points of use.

If there is a shortage of rainwater or

manual changeover, the break tank is

topped up automatically, on demand

with mains water complying with

DIN EN 1717.

The solenoid valve is also checked

regularly, in order to avoid stagnant

water in the mains water line.

Technical Description

Twin pump unit, multistage, self

priming horizontal pumps and

alternative start.

Option to connect a second supply

pump for two cistern operation.

Maximum flow up to 25 m3/h.

Electronic controller with four

Line LCD display.

Hours run counter for each pump.

Twin pump unit pressure indicator..

Catchment tank level gauge (optional).

Manual changeover to mains a water

mode (optional).

Volt free BMS fault alarms.

RS 232 interface.

Powder coated sheet steel cabinet.

Benefits

High quality, professional system

engineering.

Quick and simple installation.

Specially developed automatic

controller.

High degree of operational safety.

Performance curves at 2900 rpm

Dimensions and weights

ModelWidht

[mm]

Height

[mm]

Depht

[mm]

Weight

(empty)

Max

weight

Pressure

line

Booster

pump

Mains

water

Header tank

volume

Emergency

overflow

SP 100H 20-50 800 1670-1690 725 200 370 11/2’’ male 11/2’’ male 11/4’’ male 200 Ltrs DN 100

SP 100H 20-60 800 1670-1690 725 200 370 11/2’’ male 11/2’’ male 11/4’’ male 200 Ltrs DN 100

SP 100H 25-50 800 1670-1690 725 215 385 2’’ male 11/2’’ male 11/4’’ male 200 Ltrs DN 100

SP 100H 25-60 800 1670-1690 725 215 385 2’’ male 11/2’’ male 11/4’’ male 200 Ltrs DN 100

Technical specification

ModelMax flow rate

[m3/h]

Max head

[mtrs]

Current drain

[2x 400 V]

Motor output P1

[kW]Supply voltage

SP 100H 20-50 20 48 2x 3.5 amps 2x1.5 400 V / 3 ph / 50 Hz

SP 100H 20-60 20 60 2x 5.1 amps 2x 2.2 400 V / 3 ph / 50 Hz

SP 100H 25-50 25 48 2x 3.5 amps 2x 1.5 400 V / 3 ph / 50 Hz

SP 100H 25-60 25 60 2x 5.1 amps 2x 2.2 400 V / 3 ph / 50 Hz

220

Page 221: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

255

Rainwater G Tanks Commercial Rainwater Harvesting

Underground domestic/commercial water tanks

Applications

UK manufactured underground water

tanks designed to minimise dig-depth.

Materials

Single piece construction.

Delivered ready for installation.

Equipment

Available in seven sizes 1800, 2600,

3400, 4400, 5200, 6800, 8400,

10000 ltrs.

Bare or fitted tank options (fitted means

with calmed inlet, drainage connections,

filter priced separately).

Single & twin neck options (300 mm

vertical adjustment).

Single or twin telescopic lid options (T).

A range of filters can be included for an

additional cost.

Limitations

15 Year warranty in normal use.

Dimensions and weights

ModelCapacity Nominal

[Ltrs]

Opening dia

[mm]

Lenght

[mm]

Height

[mm]

Widht

[mm]

Weight

[Kg]

G1800 1800 625 2080 1725 1260 85

G2600 2600 625 2880 1725 1260 120

G3400 3400 625 3680 1725 1260 155

G4400 4400 625 4510 1725 1260 200

G5200 5200 625 2700 1725 2700 240

G5200T 5200 2x 620 2700 1725 2700 245

G6800 6800 625 3420 1725 2700 350

G6800T 6800 2x 620 3420 1725 2700 350

G8400 8400 625 3970 1725 2700 387

G8400T 8400 2x 620 3970 1725 2700 387

G10000 10000 620 4770 1725 2700 466

Telescopic lid

221

Page 222: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

256

S-Line Display System Commercial Rainwater Harvesting

A flexible and innovative system to display performance data and water savings for rainwater harvesting system

Applications

Digital display of selected performance.

Figures and water savings.

Display of the level in the rainwater tank.

Record of long term consumption.

Description

The S-Line Commercial Display System is

an innovative add-on module that has

been newly developed for rainwater

recovery systems.

It allows the functionality and performance

of a commercial rainwater system to be

presented in public areas.

It consists of a LCD monitor, a system

controller and further accessories. Based

on various parameters it determines and

display current rainwater and mains

water use. In the SP-50 and X-Press the

set also includes a flow rate sensor c/w

box to determine levels of consumption.

The S-Line Commercial Display System

can also display the current level

of rainwater in the rainwater tank

(optional). It is also possible to record

and show long term consumptions.

As an option, a customer specific animation

or background can be integrated at

any time.

The S-Line Commercial Display System

can be additionally equipped with a

GSM modern to run a remote diagnosis

feature. If it has an internet connection it

is also possible to access the system

using integrated software and also

to changes settings. Distances up to

1.000 mtrs can be achieved using the

optional LAN repeater.

Because it uses a computer based

platform the S-Line Commercial Display

System is open to a range of extensions

and modifications. The monitor can be

located almost anywhere because of it’s

a compact dimensions.

The device has been conceived to run

fully independently and permit remote

access when integrated in an existing

network structure.

It has also been designed without any

active user interface, so accidental

mistakes by the user and ruled out,

guaranteeing error free operation. An

invisible stop button makes the Windows

interface accessible at any time, facilitating

configuration by an administrator.

The ethenet graphic adaptor makes it

possible to send the signal to any

conventional LCD or TFT monitor.

The operating times of the S-Line

Commercial Display System can be

adapted to suit the customer, to achieve

the best possible energy efficiency.

Technical Specification

Add-on module to display performance

and status figures of commercial

rainwater systems.

S-Line standard display layout can be

customised (optional).

Standard display 22’’ LCD monitor.

Connection of impulse water meters

possible.

Fully fledged mini computer with XP OS.

Compatible with all S-Line commercial

System controllers (SP-50/75/100&

X-Press 50/100).

Bespoke operation time can be defined,

the System starts and stops fully

automatically.

Comprehensive optional accessories,

GSM modem, Powerline, LAN repeater etc.

Benefits

Performance of an installed rainwater

system can be shown in plant rooms,

or remotely in public receptions or

entrance areas.

Display with digital screen offers

customised layout options (optional).

Easy and compact installation, no

external water meters required.

Possibility to integrate into an existing

data network infrastructure.

Technical Data

Storage Capacity: 80 GB.

Operating System: Windows XP (32 Bit).

RAM: 2 GB.

Processor: 1.8 GHz Via.

Display size: 22 LCD.

Power rating max: 27 W.

Operating Voltage: 12 Volt DC.

Sound Level: 22 dB.

Optional Accesories

Powerline adaptor.

GSM Modem (remote control).

LAN repeater.

W-LAN stick.

Various display sizes.

222

Page 223: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

257

UV System Commercial Rainwater Harvesting

Stainless steel UV lamp with disinfection output 30 m3/h.

Applications

Mains water.

Water of domestic use.

Against legionella.

Disinfection of fish ponds or pools.

Description

The S-Line UV water disinfection is

characterised by construction and a

high degree of efficiency respecting

to disinfection and energy consumption.

UV disinfection is reached by floating

the water through the reactor.

Inside the reactor an UV lamp enclosed

in a UV-C transparent quartz pipe is

surrounded by the water to be treated.

The small distance of 27.5 mm between

the quartz pipe and the inner surface of

the reactor ensures optional irradiation

and therefore optimal disinfection of

the water.

The compact construction design

enables an easy replacement of the UV

lamp at the end of their useful lifetime.

No tools are required.

Also replacement and cleaning of the

quartz pipe can be arranged easily.

The S-Line UV water disinfection can

also be equipped with an optional

potential volt free output.

Therefore it is possible to transfer data to

the building maintenance information

system.

With the optional luminosity sensor you

also can measure the intense of the

lamp to avoid pollution of the quartz

pipe.

Technical Description

8.000 hours life time of lamps.

Potential volt free output (optional).

Stainless steel 1.4571.

Quality quartz pipe.

Benefits

No chemicals required.

Low operating costs.

Minimum space requirement.

Installation in existing pipework.

Smell and taste of the water are not

influenced.

Technical specification

ModelDiameter

[mm]

Lenght

[mm]

Connection

[mm]

Cable

lenght

[mtrs]

Flowrate

(max)

[m3/h]

Pressure

(max)

[bar]

UV dose

[J/m2]

Weight

[Kg]

Protection

class

Nominal

power

[W]

Connection

voltageUVC

UV (Type 1) 85 928 11/2’’ male 1.5 15 10 400 5.5 IP 65 105 230V/50 Hz 90% T1cm

UV (Type 2) 85 928 11/2’’ male 1.5 30 10 800 11 IP 65 210 230V/50Hz 90% T1cm

223

Page 224: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

258

To work in installations for rain water recovery

Rainsub Commercial Rainwater Harvesting

Applications

To work in installations for rain water

recovery.

Materials

Outer case and impellers in stainless

steel AISI 304.

Diffusers in Noryl

(glass-loaded polymer).

Motor shaft in stainless steel AISI 420.

Double mechanical seal in graphite

and alumine.

Motor

Water-cooled motor.

Class F insulation.

Protection IP 68.

Continuous operation.

Single-phase motor with built-in thermal

protection.

Limitations

Maximum liquid temperature: 40 °C.

Equipment

Complete with 15 m of power cable.

Equipped with a suction base,

connection for a floating suction.

Hydraulic performance table

Performance curves at 2900 rpm

7

6

5

4

3

I [A]

1~

230 V 400 V3~

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

3~

400 V

c

[μF] m3/h

l/min

0.6

10

1.2

20

1.8

30

2.4

40

2.7

45

3.0

50

3.6

60

2.8

3.5

4.1

5.0

5.5

1.2

1.7

1.9

2.0

2.4

0.6

0.8

1

1.2

1.4

0.6

0.8

1

1.1

1.3

0.37

0.5

0.75

0.9

1.1

0.5

0.75

1

1.2

1.5

12

12

12

16

30

33

41

50

60

70

29

37

46

55

64

26

32

40

47

55

21

26

32

37

44

18

22

27

32

38

15

19

23

26

31

8

10

13

15

18

4

6

8

9

11

3.9

65

mw

c

Rainsub 07N 3

Rainsub 07N 4

Rainsub 07N 5

Rainsub 07N 6

Rainsub 07N 7

224

Page 225: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

259

Stainless steel multistage submersible with bottom intake

Rainsub 2AL Commercial Rainwater Harvesting

Applications

To work in installation for rainwater

recovery. Equipped with two bottom

inlets, one to be capped of for UK

market.

Materials

Outer case and impellers in stainless.

Steel AISI 304.

Diffusers in Noryl (glass-loaded polymer).

Motor shaft in stainless steel AISI 420.

Double mechanical seal in graphite and

alumine.

Materials

Water cooled as standard.

Class F insulation

IP 68 protection.

Continuous operation.

Complete with built-in thermal

protection.

Equipment

Complete with 15 mtrs of power cable.

Limitations

Maximum liquid temperature 40 °C.

Hydraulic performance table

Performance curves at 2900 rpm

30

60

80

140120100806040200 Q [l/min]

876543210 Q [m3/h]

70

60

50

40

30

20

10

0

H

[m]

Model

I

[A]

P1

[kW]P2 c l/min 10 20 30 40 60 70 80 90

1~

230 V

1~

230 V[kW] [HP] [μF] m3/h 0.6 1.2 1.6 2.4 3.6 4.2 4.8 5.4

Rainsub 2AL 30 4.2 0.9 0.6 0.8 20

mw

c

33 32 28 25 20 14 10 3

Rainsub 2AL 60 6 1.3 0.9 1.2 25 55 54 50 44 36 27 18 8

Rainsub 2AL 80 8 1.8 1.2 1.6 40 80 78 72 66 55 42 29 13

225

Page 226: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

260

Accessories Commercial Rainwater Harvesting

Equipment

IRM-floating extraction TWIST with 1

m or 2 m hose for flexible extraction

of rainwater from the storage tank, pre-

assembled

including: 1 x 1 mm sieve with

PE-floating ball prevents the pump from

drawing sediments. 1 x high quality 1”

check valve. 1 x special 1” rubber spiral

hose prevents germs forming, length

2 m. 1 x brass 1” BSP threaded coupling

as passage tank including seal.

Article available also with 3 m hose.

Application

Rainwater harvesting for domestic

and commercial use.

For tanks where rainwater is filtered

(TWIST) or unfiltered (SAFF) prior

to holding tank. To extract cleanest

water, place 15 cm below water surface.

Floating suction

Deflector U TrapDownpiepe filter

Description

Rainwater filter with plastic shaft

extension tube for direct installation

in the ground before the tank, with

locking lid. This extension permits

an easy adaptation to the height

proportions at the moment of the

installation on site. If necessary,

the telescopic extension can also be

shortened. It is also possible to use

several extensions. Two step cleaning

system, therefore high level of filtering

efficiency, independent of flow rate.

Due to the steep inclination of the filter

cartridge the dirt is continuously cleaned

away into the sewer.

Connection capacity according to

DIN 1986 for roof areas up to 350 m2.

Max. Flow Rate Sieve insert 1,5 lt/sec.

= 5,4 m3 cleaned water per hour.

Height difference between inlet

and outlet just 300 mm.

The cleaned water can be used in

washing machines, toilet flushing

and garden watering, in homes,

in commerce, in public buildings

and in industry.

The filter has to be cleaned depending

on the contamination 1-2 times during

the year.

3P Volume Filter VF1

How it works

1. As water arrives the level builds

up and is equally distributed across

the cascade.

2. Pre cleaning through the cascades.

Largest dirt particles are led across the

primary filter cascades directly to the

sewer.

3. Pre filtered water then flows over the

secondary filter sieve (mesh size 0,65

mm). Due to the special mesh structure

of the sieve, any dirt washes directly into

the sewer which means the filter is self

cleaning, with very low maintenance.

4. Cleaned water flows to the tank.

5. Dirt goes to the sewer

Technical data

Filter according to DIN 1989-2, typ C.

Connection inlet: 2 x DN 110.

Outlet into tank: DN 110.

Outlet into sewer: DN 125.

Height difference between rainwater

inlet and outlet 300 mm.

Housing material: Polyethylene.

Filter cartridge: Stainless steel 1.4301.

Mesh size: 0,65 mm.

Telescopic extension: Polyethylene.

Weight: 10,2 kg.

226

Page 227: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

261

ACCESSORIES/CONTROL PANELS& INVERTERS

Page 228: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

262

Accessories Accessories

Acuaria Ref.

12μf 8200051001

16μf 8200051002

25μf 8200051005

30μf 8200051006

50μf 8200051010

Pressure switches Ref.

Square D 65 psi 0-4 bar 5140041027

Telemecanic 0-6 bar 5140041034

Telemecanic 0-12 bar 5140041035

Teddington type 0-6 bar HLP506

Danfos KPI35 0-8 bar ZPSKPI35

Cable jointing kits for submersible applications Ref.

Thermal joint kit 369210000

Resin joint kit 1-4mm2 8500000004

Resin joint kit 5-10mm2 8500000010

Floating level switches Ref.

Olympic water float switch c/w weight 3mtr ZIN15/3T

Olympic water float switch c/w weight 10mtr ZIN15/10T

Taurus sewage float switch PVC 10mtr VVF A07 3X1-10M

Cast iron wafer non-return valves dual plate Ref.

21/2’’ EPDM seat, ss disc 16 bar ACSC121250

3’’ EPDM seat, ss disc 16 bar ACSC121300

4’’ EPDM seat, ss disc 16 bar ACSC121400

6’’ EPDM seat, ss disc 16 bar ACSC121600

Cast iron wafer butterfly valves lugged and tapped Ref.

21/2’’ EPDM liner, 316 ss disc ABUT135250

3’’ EPDM liner, 316 ss disc ABUT135300

4’’ EPDM liner, 316 ss disc ABUT135400

6’’ EPDM liner, 316 ss disc ABUT135600

Brass Non-Return valves F/F Ref.

1’’ Brass F/F 25 bar 4051.8

11/4’’ Brass F/F 18 bar 4051.9

11/2’’ Brass F/F 18 bar 4051.1

2’’ Brass F/F 18 bar 4051.11

Ball valves M/F Ref.

1’’ Brass M/F 25 bar ART56-100

11/4’’ Brass M/F 25 bar ART56-125

11/2’’ Brass M/F 25 bar ART56-150

2’’ Brass M/F 25 bar ART56-200

228

Page 229: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

263

Accessories Accessories

A

C

D

B

To prevent water hammer in pressurised systems with minor leaks.

Model

Kit Press 148 135.5 1/4” 124

A B C D

8500000107

Ref.Brass Connectors Ref.

Brass 5 way 1’’ 5100041

Brass 5 way 11/4’’ 5100042

Pressure gauges (bottom connection) Ref.

50mm dial 1/4’’ 0-10 bar/psi 600201

63mm dial 1/4’’ 0-6 bar 5100041026

63mm dial 1/4’’ 0-10 bar 5100041024

63mm dial 1/4’’ glycerin filled 0-6 bar/psi 600302

63mm dial 1/4’’ glycerin filled 0-10 bar/psi 600300

63mm dial 1/4’’ glycerin filled 0-16 bar/psi 600303

Flexible hose connectors Ref.

3/4’’ M/F 50cm long 5160081008

1’’ M/F 50cm long 5160081014

11/4’’ M/F 50cm long 5160081020

11/2’’ M/F 50cm long 5160081027

2’’ M/F 50cm long 5160081033

PM10 Single phase submersible motor control starter/protector

Model Code

Power

Indicative at

230 kW

Power

Indicative at

230 HP

Running

Capacitor

Thermal

ProtectionWeight [Kg]

Dimensions

[mm]

A

Dimensions

[mm]

B

Dimensions

[mm]

F

PM10/0.37kW-16C-4T-IL-2 231.81 0.37 0.5 16μF 4A 0.5 210 115 70

PM10/0.37kW-20C-4T-IL-2 231.82 0.37 0.5 20μF 4A 0.5 210 115 70

PM10/0.55kW-20C-6T-IL-2 231.83 0.55 0.75 20μF 6A 0.5 210 115 70

PM10/0.55kW-25C-6T-IL-2 231.84 0.55 0.75 25μF 6A 0.5 210 115 70

PM10/0.75kW-25C-7T-IL-2 231.85 0.75 1 25μF 7A 0.5 210 115 70

PM10/0.75kW-30C-7T-IL-2 231.86 0.75 1 30μF 7A 0.5 210 115 70

PM10/0.75kW-35C-7T-IL-2 231.87 0.75 1 35μF 7A 0.5 210 115 70

PM10/1.1kW-35C-10T-IL-2 231.88 1.1 1.5 35μF 10A 0.5 210 115 70

PM10/1.1kW-40C-10T-IL-2 231.89 1.1 1.5 40μF 10A 0.5 210 115 70

PM10/1.1kW-40C-12T-IL-2 231.90 1.1 1.5 40μF 12A 0.5 210 115 70

PM10/1.5kW-40C-13T-IL-2 231.91 1.5 2 40μF 13A 0.5 210 115 70

PM10/1.5kW-45C-13T-IL-2 231.92 1.5 2 45μF 13A 0.7 210 115 70

PM10/1.5kW-50C-13T-IL-2 231.93 1.5 2 50μF 13A 0.7 210 115 70

229

Page 230: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

264

ONE Electronic control box for one pump 1 ph or 3 ph

Model CodeOperating current Recommended Applications Weight

[Kg]

Dimensions

[mm]

H

Dimensions

[mm]

W

Dimensions

[mm]

O

Notes

min [A] max [A] [KW] [KW] [KW]

QM10/17A.A-ONE 529.01 1 17 0.09 2.2 4 300 220 160 F

QM10/17A.A-ONE+K+ 529.02 1 17 0.09 2.2 4 300 220 160 F

QT10/9A.A-ONF 529.13 1 9 0.25 3 4 5.5 300 200 160 F

QT10/17A.A-ONF 529.15 1 17 0.25 5.5 7.3 5.5 300 220 160 F

QT10/23A.A-ONF 529.17 2 23 0.75 7.5 11 7.5 300 220 160 F

QT10/29A.A-ONF 529.18 2 29 0.75 11 15 7.5 300 220 160 F

QT10/35A.A-ONF 529.19 2 35 0.75 15 18.5 7.5 300 220 160 F

Accessories Accessories

PT10 Switch start & stop 3 ph

Model Code

Current

ApplicationRecommended Applications

Weight

[Kg]

Dimensions

[mm]

A

Dimensions

[mm]

B

Dimensions

[mm]

P

NotesSubmersible pumpsSurface pumps and

general motors[A]

[kW] at 400V [kW] at 400V

PT10/1.5A- T -IMA 518.06 0.9 -1.4 0.25 0.37 0.8 184 88 140 P

PT10/2A- T -IMA 518.08 1.3 -2.1 0.55 0.75 0.8 184 88 140 P

PT10/3A- T -IMA 518.09 1.9 - 3 0.75 1.1 0.8 184 88 140 P

PT10/4.5A- T -IMA 518.10 2.9 - 4.5 1.1 1.5 0.8 184 88 140 P

PT10/7A- T -IMA 518.12 4.3 -6.8 1.5 3 0.8 184 88 140 P

PT10/9A- T -IMA 518.13 5.7 - 9.1 3 4 0.8 184 88 140 P

PT10/14A- T -IMA 518.14 8.6 - 13.5 4 5.5 1 202 88 155 P

PT10/17A- T -IMA 518.15 12.5 - 16.5 5.5 7.5 1 202 88 155 P

PT10/21A- T -IMA 518.16 16 - 21 7.5 9 1.2 234 110 169 P

PT10/23A- T -IMA 518.17 19 - 23 9 11 1.2 234 110 169 P

PT10/29A- T -IMA 518.18 22 - 29 11 15 1.2 234 110 169 P

230

Page 231: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

265

Control Panel Q2P Accessories

Control Panel for two booster pumps fixed speed

General features

Control panel for 2 motor pumps with

electronic protection, Q2P series.

Power supply:

Q2PME16EI Single phase:

1~ 50/60 Hz 230/240 V ±10%.

Q2PTE08EI Three phase:

3~ 50/60 Hz internal selection

for 230/240 V or 400/415 V ±10%.

Main disconnector with door lock.

Thermoplastic enclosure.

IP 55 protection rating.

Power section

2 motor pump outputs: single phase or

three phase with built-in capacitor

(depending on model).

Direct motor start-up.

Control inputs

4 very low voltage inputs for float or

pressure switch for:

Shut-down level or shut-down

pressure (S0 input).

Motor pumps control level or motor

pumps control pressure (S1, S2 inputs).

Alarm level or alarm pressure (W input).

Controls and signals

2 buttons for each motor pump for:

AUTOMATIC / RESET alarm.

MANUAL / OFF.

Enabling of motor data self-learning

function (current and cos ) for

operating.

3 indicator lights to show:

Power presence and/or failure.

Stop sensor intervention (S0 input).

Alarm sensor intervention (W input).

3 indicator lights for each motor pump

to show:

Operating mode (AUTOMATIC/OFF/

MANUAL).

Motor state (running, stand still due to

dry running protection intervention) with

individually distinguishable signals.

Motor protection triggered (due to over

current or minimum charge) with

individually distinguishable signals.

Acoustic signal for:

Continuous for system alarm: W input,

S0 input (excludable), dry running

protection intervention

(excludable).

Intermittent acoustic signal for:

Motor alarm: intervened protection

(due to over current or minimum

charge).

Single and double acoustic signal for:

Warning off internal selectors

particular settings.

Functions which can be set by selectors

Auxiliary functions:

Reversing polarity of shut-down input S0.

Reversing polarity of alarm input W.

Latching for motor pumps shut-down

only from input S0, while starting

depends on input S1 and S2 (useful

for drainage systems).

Alternating motor pumps starting and

motor pumps exchange in case of

12 hours uninterrupted operation.

Alarm warning for intervention on

shut-down input S0 or for dry

running protection intervention.

Ever-active motor protection (over

current, minimum charge, dry running)

or temporarily disabled motor

protection (10 sec.).

Motor protection against dry running.

Functions which can be set by

potentiometers

Protection intervention threshold due to

over current of motor 1 and motor 2:

Automatically delayed starting (0-30 sec.)

of the second motor started.

Automatically delayed shut down

(0-180 sec.) of the first motor started.

General functions

Delay (10 sec.) of motor pumps starting

after power supply restoration.

Automatic non contemporaneous

starting and shut down of the

pumps, with 2 seconds interval time,

if not differently set on “delay

second pump starting”potentiometer

and “delay first pump shut down”

potentiometer.

Automatic periodic impeller release

(running 2 sec. every 48 hours).

MANUAL running could be:

PERMANENT: (by briefly pressing

the command button) with

control from input S0 or from

dry running protection enabled.

TEMPORARY: (by holding down the

command button) with control

from input S0 or from dry

running protection disabled.

Alarms and protections

Float or pressure shutdown

intervention (input S0): motor

pumps shutdown.

Float or pressure alarm intervention

(input W): only warning, without

motor pumps shutdown.

Intervention of protection against

motor over current with accumulated

energy calculation (I2t): causing

motor pumpm shutdown.

Intervention of protection against

motor minimum charge: causing

motor pump shutdown.

Intervention of protection against dry

running: causing motor pump

temporary shutdown with periodic

attempt of restoration (every 10 min.).

Motor 2 starting, if available, when

motor 1 is shut down by any

protection (except for dry running).

Protection fuses for each motor (2 for

Q2PME16EI and 3 for Q2PTE08EI ).

Auxiliary circuits protection fuses.

Operating conditions

Ambient Temperature -5/+40 ÆC

Maximum relative humidity 50% with

maximum temperature +40ÆC.

Technical features and power section

Model

I

[A]

P1

[kW] Height

[mm]

Widht

[mm]

Depht

[mm]

Weight

[Kg]Notes

230 V 400 V 230 V 400 V

Q2PME16EI 1 - 16 0.09 - 2.2 245 195 150 1.8 P

Q2PTE08EI 1 - 8 1 - 8 0.12 - 1.8 0.25 - 3.7 245 195 150 2.5 P

231

Page 232: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

266

Water Filters Accessories

Two & three piece filters

The BIG line is a 2 piece filter housing designed for medium sized cartridges.

It is suitable for situations where a certain quantity of water is required to be

filtered.

Available, with opaque (Blue PP) or transparent (SAN) bowls, designed for wall

mounting.

The Standard Line includes FP2 cartridges with two-piece plastic filters & FP3

cartridges with three-piece plastic filters. The heads are made with female-

thread couplings with brass inserts and brass blow-off valves, or without brass

inserts with plastic relief valves. They allow handling medium capacities, and

are particularly suitable for domestic or residential use.

Part of the High Pressure Line the FO3 with brass head & TROGAMID transparent sump

is ideal for semi-professional land industrial applications where excellent performance

is required due to the presence of chemical products, high working pressures and/or

temperatures. This durab three pieces filter housing is suitable for wall mounting & easy

to install.

The Washable Net Cartridge is ideal

for applications such as the water

treatment, industry, agriculture,

domestic applications & water pumps

removing suspended solids, sand,

slime, rust etc. Properly utilized, they

can be used over & over again, with

uniform flow along the cartridge

surface minimising the risk of

clogging, maintaining constant

efficiency.

The FA-line is our polypropylene wound

Cartridge part of the depth and

deforming cartridges series.

Manufactured using only 100% pure

non-toxic polypropylene yarn, the

appearance is uniform, homogenous

and very strong, achieving a notable

increase in the filtration surface, thus

increasing in cartridge life. The inside

core of the filter is rigid polypropylene

which guarantees stability.

Contacting head water meter, Suitable for horizontal installation,

available in several sizes & K factors.Single/double brackets & spanner available.

232

Page 233: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

268

Electronic variable speed pump controller with inverter technology for single & multi pump applications

Steadypres Inverters

Applications

An in-line inverter for boosted water

supply, irrigation & bore-holes.

Features

Steadypres features a tecnopolymer

body suitable for use with pumps with

flow rates up to 220 Litres/min.

Heat emission is a characteristic of all

Inverters when they are working and its

Dissipation is extremely important for

reliability.

Steadypres keeps its cool thanks to a

metallic heat sink with large cooling ribs

in direct contact with the water flow.

High energy savings.

Constant water pressure.

Safety and reliability.

Expanding Signal board (optional)

The Input/output signal board is fitted in

the back of the unit and includes

connections for:

RS 485 communication signal for use

with multi pump installations.

Float switch (or other input signal):

allows the connection to a level sensor

or other switch for remote start-stop

signal.

Alarm output for remote alarm.

Sinwave Filter (Installed between

Steadypres & pump motor) used to

overcoming problems associated with

long cables. It aids smooth running of

motors eliminating destructive effect of

voltage peaks. It permits the use of up

to 300 mtrs between inverter and the

pump motor.

Typically associated with borehole

pumps.

There are two models for 9 amps &

16 amps.

Technical

Input voltage (all models):

Single phase 230 V at 50/60 Hz.

Single phase 110 V at 50/60 Hz.

Output voltage:

Single phase 230 V at 50/60 Hz.

Single phase 110 V at 50/60 Hz.

Three phase 230 V at 50/60 Hz.

Three phase 110 V at 50/60 Hz.

IP 65 protection.

Working temperature 0-60 deg c.

Max flow rate 200 l/min.

Connections 1’’ BSP/1’’NPT male.

Max working pressure 10 bar.

Burst pressure 40 bar.

Weight 2.9 Kg.

Shut-off flow rate 2 l/min.

Working pressure 1-9 bar.

Protection against:

Dry running.

Over current.

Over temperature.

Pump failure.

You only need to select the required

operating pressure and the rated

current of the pumps.

Technical features

Model Input voltage Output voltage Max current Power [kW]

ST M/M 07E 1 ph 230 V 1 ph 230 V 8.5 amps 1.1 kW

ST M/M 11DE 1 ph 230 V 1 ph 230 V 13 amps 1.7 kW

ST M/M 13DE 1 ph 230 V 1 ph 230 V 16 amps 2.2 kW

ST M/T 07E 1 ph 230 V 1 ph 230 V 7 amps 1.1 kW

ST M/T 10E 1 ph 230 V 1 ph 230 V 12 amps 2.2 kW

ST T/T 06E 3 ph 400 V 3 ph 400 V 6 amps 2.2 kW

ST T/T 08E 3 ph 400 V 3 ph 400 V 8 amps 3 kW

Performance curves

233

Page 234: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

269

DG Box is a control panel for managing variable speed & fixed speed pumps

DG Box Inverters

Applications

An in-line inverter for boosted water

supply, irrigation & bore-holes.

Features

Frequency inverter (s).

Main circuit breaker with door isolator.

Thermal circuit breaker (for variable

speed pump(s).

Contactor with overload protection

(for fixed speed pump).

2x Analog input 4-20 mA (0-110 V) for

pressure transducer.

2x Digital input for flow signal.

2x Digital signal (input signal).

2x Digital signal (output signal).

USB port for software updates & restore.

RS 485 port.

Control board protection fuse.

Net filter (integrated).

Cooling fans.

Technical

The double fan forced cooling system

combined with the IP 65 cabinet allow

the usage of the DG Box even with

ambient temperatures up to 40 deg c.

The DG Box is equipped with built-in

electronic filter as per EMC requirements.

A back lighted graphic LCD make

configuration and usage simple

and safe.

Power and signal electronic connections

are safe and easy thanks to the wide

separate compartment and quick

connections.

Technical features

Panel c/w one inverter to control one pump.

Model kW AMPS Power

MV - 30 3 8 400 V

MV - 55 5.5 14 400 V

MV -75 7.5 19 400 V

Panel c/w one inverter to control two pumps.

Model kW AMPS Power

MVF - 30 2 x 3 2 x 8 400 V

MVF - 55 2 x 5.5 2 x 14 400 V

MVF -75 2 x 7.5 2 x 19 400 V

Panel c/w two inverters to control two pumps.

Model kW AMPS Power

MW - 30 2 x 3 2 x 8 400 V

Second pump with contactors

234

Page 235: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

270

Improved quality in water supply: constant pressure

Speedrive

Performance area with sets of 4 pumps in parallelPerformance area with one pump

2520151050

4003002001000 Q [l/min]

Q [m3/h]

20 40 60 80 100Imp g.p.m.

250

200

150

100

50

0

H

[ft]

600

800

200

400

0

H

[kPa]

60

80

40

20

0

H

[mca]

806040200

1400120010008006004002000 Q [l/min]

Q [m3/h]

100 200 300Imp g.p.m.

250

200

150

100

50

0

H

[ft]

800

600

400

200

0

H

[kPa]

80

60

40

20

0

H

[mca]

The most efficient system for adjusting

a pump’s hydraulic performance

to the pressure and flow requirements

of supplying water is through the use

of variable-speed technology. In the

case of supplying water to a building

that requires a constant pressure

regardless of the water flow requested,

with a variable-speed system, in addition

to improved efficiency, a high-quality,

oscillation-free service is obtained,

guaranteeing greater durability of

the equipment and the installation.

The ESD unit receives a proportional

signal from a pressure transducer fitted

on the discharge pipeline. The ESD

processes this signal and regulates

the motor speed in order to keep the

pressure constant at the established

level, regardless of the variations in flow

demand. With this pump set the pump’s

operation can be adapted to the

different flow demands, constantly

setting the consumption that is strictly

necessary for the demand at any given

moment. The energy consumption

will be proportional to the water

consumption. In comparison to the

same system running at a fixed speed,

this translates directly into energy

savings.

Operating modes

The ESD has a backlit display and a

5-button keypad for displaying the user

parameters. The installer can easily

regulate and modify the basic

operational parameters through

the same interface. It also includes

a reset option to recover the default

factory parameters.

Adjustable operating parameters

Language: options ES, EN, DE, IT, FR.

Operation: AUTOMATIC – MANUAL.

Set pressure: set point.

Differential pressure: hysteresis or

difference in the set pressure that marks

the start-up of the pump.

Maximum motor intensity: to regulate

motor protection.

Pump sleep frequency: sleep

frequency; this can be set manually

or automatically.

ESD has a system for automatically

calculating the pump’s sleep frequency

on the basis of the specific

characteristics of each installation

and the set pressure point.

Parameters displayed

Set pressure.

Differential pressure.

Maximum motor intensity

Stoppage frequency.

Pump stop temporisation.

Module temperature.

Alarm display: power surge, short-circuit,

power failure and module temperature.

Operational register: number

of start-ups, hours in operation

and hours online.

Access to advanced parameter settings,

the deletion of the operational register

and of the alarm history is password

protected.

Pump stop temporisation

Nominal motor frequency: 50 Hz/60 Hz.

Motor rotation reversal.

ON–OFF auxiliary pump: auxiliary pump

in fixed-speed DOL operation.

Auxiliary pump in variable speed mode

by ESD at variable speed.

Configuration in auxiliary pumps

Activation frequency: activation

frequency of auxiliary pumps.

Auxiliary pump activation temporisation.

Auxiliary pump maximum intensity.

235

Page 236: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

271

Dimensions and weights

Speedrive M2

Speedrive T3

Speedrive T4

Model A

128

142

142

B C D [Kg]

71

85

85

207

207

207

207

207

207

2.2

2.5

2.5

Speedrive

Electronic circuit

4

3

2

1

1

4

2

3

1

4

Speedrive M2 Speedrive T3/T4

1

4

2

3

EMC filter

Input/output for cables

Power circuit

Aluminium radiator body

Pressure transducer

Device for digital pressure reading

Technical specifications - 50/60 Hz

Description

Single-phase Three-phase

M2 T3/T4

Configuration

Power

Motor voltage

Maximum intensity

Cooling

Constant pressure

Constant flow

Second duty point

Dry running protection

Pressure transducer

Additional digital input

Additional analogical input

Level switch terminal

PTC

External communication port

Screen

Auxiliary relay

Minimum working frequency

Acceleration ramp

Deceleration ramp

Stop temporisation

Maximum No. of pumps

Maximum No. of slave pumps (fixed speed)

Built into the junction box

230 V, single-phase

230 V, three-phase

7 A

Air-cooled

Yes

Programmable

Programmable

Yes

External, 4-20 mA

1

1

Yes

Optional

RS 485

Backlit

1 for external alarm

Adjustable

1 fixed

1 fixed

Yes

Up to 4

Up to 3

Built into the junction box

400 V, three-phase

400 V, three-phase

9 A

Air-cooled

Yes

Programmable

Programmable

Yes

External, 4-20 mA

1

1

Yes

Optional

RS 485

Backlit

No

Adjustable

1 fixed

1 fixed

Yes

Up to 4

Up to 3

For ESPA pump model’s only XVM, Aspri, Multi, etc.

236

Page 237: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

237

Page 238: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

272

Page 239: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

273

SPECIALPUMPS

Page 240: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

274

J Series Special Pumps

Surface mounted self priming pump with open impeller

Applications

The J range pumps suit many applications,

construction, agriculture, farming, waste

treatment, civil engineering, marine, naval

and lift shafts.

Features

Robust construction.

Quick self priming.

Easy maintenance.

Solids handling.

Reliable, wear resistant.

Technical features Performance curves at 2900 rpm

Model Power supply CurveOutlet

[mm]

Free passage

[mm]

Power

[kW]

Weight

[Kg]

J40 230 V / 1 ph A 11/2’’ 20 1.1 21

J40 400 V / 3 ph A 11/2’’ 20 1.1 21

J1-180 400 V / 3 ph E 11/2’’ 11 4 60

J50 230 V / 1 ph B 2’’ 25 2.2 24

J50 400 V / 3 ph B 2’’ 25 2.2 24

J2-180 400 V / 3 ph F 2’’ 28 5.5 106

J3-140 400 V / 3 ph C 3’’ 45 4 63

J90 400 V / 3 ph D 4’’ 15 11 95

240

Page 241: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

275

Piscis Special Pumps

Quiet-running single-stage centrifugal pumps for the recirculation of water

Motor

Asynchronous, two poles.

IP 55 protection.

Class F insulation.

Continuous operation.

With built-in thermal protection

Equipment

Complete with suction and discharge

unions. In imperial or metric on

Piscis 2, 3 and 4.

Applications

Water recirculation in aquariums

and fish hatcheries. Specially designed

for operation with sea water and to be

resistant to the fish excrement.

Materials

Pump body, impeller and pump foot

in technopolymer.

Mechanical seal in graphite and alumine.

Metallic parts in contact with water in

stainless steel AISI 316.

O-rings in NBR.

Piscis 1/ Piscis 2:

Seal mounting in technopolymer.

Shaft in stainless steel AISI 316.

Motor housing in aluminium.

Piscis 3: Shaft in stainless steel AISI 316.

Motor housing in aluminium.

Piscis 4: Shaft in stainless steel AISI 316

and iron F-114.

Motor housing in aluminium L-2521.

M

L

K

J

I

D

C

A

H

GF

E

B

M

L

K

J

A

IH

G

FE

D

C

B

Piscis 1

Piscis 1

Model A [Kg]H I J LKGFEDC

125 4.538 32 100 124122888115.53059094

B

Piscis 4

Piscis 4

Model A

130

[Kg]

14.3

H

108

I

29

J

124

K

191

L

9

M

2”

G

120

F

160

E

230

D

108

C

162298.7

B

A

J

I

H

GF

E

D

C

B

H

Piscis 3

Piscis 3 50

Piscis 3 70

Model A [Kg]H I JGFEDC

134.5

134.5

7

7

50

50

120

120

100

100

154.5

154.5

113

113

156

156

8

8

337

337

83.5

83.5

B

Piscis 2

Piscis 2

Model A

396

[Kg]

6

H

150

I

88

G

33

F

39

E

257

D

158

C

182204

B

G

A

H

F

E

D

C

B

H

F

G

I

Dimensions and weights

241

Page 242: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

276

Piscis Special Pumps

Performance curves at 2900 rpm

Piscis 1 Piscis 2

Piscis 3 Piscis 4

Hydraulic performance table

1.0 0.22 0.08 0.12 6

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

7

0.9

15

6.3

1.8

30

5.7

2.7

45

4.9

3.6

60

4.3

4.5

75

3.4

5.4

90

2.2

6.6

110

0.4

8.1

135

Piscis 1 mwc

1.3 0.27 0.15 0.20 6

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

9.4

0.9

15

9

1.8

30

8.5

2.7

45

7.6

3.6

60

6.5

4.5

75

5

5.4

90

3.2

6.3

105

1.6

6.9

115

Piscis 2 mwc

6.3 1.4 1.1 1.5 25

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

14.5

1.5

25

14

6.0

100

13.2

10.5

175

12.2

15

250

11

19.5

325

9

24

400

7

28.5

475

4.2

33

550

Piscis 4 mwc

I [A]

1~

230 V

Model

P2

[kW] [HP]

P1 [kW]

1~

230 V

c

[μF] m3/h

l/min

1.2

20

3.6

60

6.0

100

8.4

140

10.8

180

12.6

210

15

250

2.4

3.3

0.5

0.7

0.37

0.5

0.5

0.75

10

10

10.5

11.5

9.7

10.8

8.5

10

7.1

9.1

5.4

7.9

4

6.8

2

5 2.7

18

300

Piscis 3 50

Piscis 3 70mwc

1 2

3-703-50

4

242

Page 243: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

277

Residue Pump LSCI.4S Special Pumps

Submersible puddle sucker pump

Applications

Installation to pump water down to 1 mm.

Flood control services, lift shafts, hire

fleetsand utilities.

Materials

Outer case in pressed steel.

Base in steel and rubber.

Shaft and stainless steel AISI 403.

Double mechanical seal in silicon

carbide/silicon carbide.

Oil in seal chamber.

Motor

Water cooled and standard.

Class F insulation.

IP 68 protection.

Continuous operation.

Complete with built-in thermal

protection.

Limitations

Maximum liquid temperature 40 °C.

Equipment

Complete with 10 mtrs of power cable.

Two outlet sizes 25 & 50 mm.

Options

SwitcH²O option for precise water level

control via probes.This should be used

in conjunction with QA50B control panel

which comes complete with the LSC1.4S

SwitcH²O pump.

Technical features Performance curves at 2900 rpm

Model Manual / AutoOutlet

[mm]

Power

[kW]

Voltage

[V]

Free passage

[mm]

dia x h

[mm]

Weight

[Kg]

LSC1.4S M 25 0.48 110 / 230 6 Ø196 x 316 12

LSC1.4S M 50 0.48 110 / 230 6 Ø196 x 316 12.1

LSC1.4S A 25 0.48 110 / 230 6 Ø196 x 316 12.1

LSC1.4S A 50 0.48 110 / 230 6 Ø196 x 316 12.2

H

[m]

10

5

0

243

Page 244: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

278

Industrial process Special Pumps

F range Free Moulded Pumps

Range available:

FM-S OR FM-C

Flow rates up to 10,000 l/hr

Pressure up to 4 bar.

K range

Flow rates up to 200 m3/h.

Pressure up to 24 bar.

Special on request up to 48 bar.

W range Standard Open Throat

Flow rates up to 100 m3/h.

Pressure up to 24 bar.

Macerator

C31 pump self priming PC screw pump.

The bi-hammer macerator reduces

particle size before entering the

pumping element.

Capacity: up to 3.5 m3/h. & up to 6 bar.

For further information, please ask our sales team for a quotation.

244

Page 245: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

279

TECHNICALINFORMATION

Page 246: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

280

Technical Information

Table 1 Pipe dimension in function of the flow

Table 2 Equivalent pipe length (in m)

DN

Ø PVC

Inces

Thread

Maximum suction flow [m3/h]

Maximum nominal flow [m3/h]

20

25

3/4”

20/27

0.7

0.8

25

32

1”

26/34

1.4

1.4

32

40

1 1/4”

33/42

2.7

3

40

50

1 1/2”

40/49

4.2

4.5

80

90

3”

80/90

21

25

150

160

6”

152/165

91

130

125

140

5”

127/140

60

80

100

110

4”

102/114

36

46

65

75

2 1/2”

66/76

13.5

16

50

63

2”

50/60

7.3

8

DN

90° Threaded elbow

90° Flanged elbow

Flow Straightner

Non return valve

Foot valve

25

1

0.4

0.3

6

4

32

1.3

0.5

0.3

7

5

40

1.6

0.6

0.4

8

7

80

3.2

1

0.7

10

15

150

6

2

1.4

18

34

125

5

1.8

1.1

15

26

100

4

1.5

0.9

12

20

65

2.6

0.9

0.6

10

11

50

2

0.7

0.5

10

9

Definitions

Flow

The quantity of liquid at the output

of a pump on a time basis.

It is generally expressed in m3/h.

Total Manometric Head

The THM is the total pressure that the

pump must supply. It is generally

expressed in meter water column (mwc).

Friction Losses

Any liquid flowing through a pipe

generates friction losses they are

function of: flow, the cross section

of the pipe used and the number of

accessories used by the liquid.

Abreviations

ha Inlet pressure. Vertical distance

between the axis of the pump and the

minimum level of liquid to pump. ha is

positive if the level of the pumped liquid

is above the axis of the pump, and is

negative when the level is below.

La Total length of the suction pipe.

hr Head requirement. Vertical length

between the axis of the pump and the

highest point of distribution.

Lr Total length of discharge piping.

Jr Outlet losses.

Pu Utilised pressure. Pressure required

for process (e.g. at sprinkler or shower

head).

Calculation of the HMT

Inlet Manometric Height: HMA = ha + Ja

Outlet Manometric Height: HMR = hr + Jr

Total Manometric Head: HMT = HMA +

HMR + Pu

Example

Requested Characteristic: Flow: 2 m3/h

Utilised Pressure: 2 bars = 20.2 mCE

Installation Parameters:

Inlet: ha = 4 m, La = 7 m, 1 x Foot valve

1 x 90 degree elbow

Outlet: hr = 6 m

Lr = 60 m

1 x Check valve

1 x Valve

1 x 90 degree threaded elbow

Pump Selection:

Recommended dimension of the pipe

(Table 1):

DN 32 Equivalent length of the pipe

(Table 2):

7 + 5 + 1.3 + 60 + 7 + 0.3 + 1.3 = 81.9 m.

Pipe losses (Table 3):

81.9 x 2 / 100 = 1.6 mwc.

Total manometric head:

HMT = 4 + 6 + 1.6 + 20.2 = 31.8 m CE.

This installation requires a pump with

a 2 m3/h flow at 32 mwc:

The Tecno 15 4 is the most suitable

pump for this application.

246

Page 247: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

281

Technical Information

Table 4 Reduction of a pump capacity

Altitude [m]

0

500

1.000

1.500

2.000

2.500

3.000

3.500

Head loss [mwc]

0.6

1.15

1.70

2.20

2.65

3.20

3.60

Temperature [°C]

20

30

40

50

60

70

80

90

100

Head loss [mwc]

0.20

0.40

0.70

1.20

1.90

3.10

4.70

7.10

10.33

Deration due to pumped liquidDeration due to altitude

Table 3 Losses in metres for 100m of horizontal straight pipe

For pipes in plastics, multiply these values by the following 0,8 factor

[m3/h]

0.2

0.5

0.7

1.0

1.5

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

12.0

15.0

20.0

25.0

30.0

40.0

50.0

60.0

70.0

80.0

100.0

150.0

200.0

l/min

3

8

12

17

25

33

50

67

83

100

117

133

150

167

200

250

333

417

500

667

833

1000

1.167

1.333

1.667

2.500

3.333

20

0.3

2.0

4.0

8.0

17.0

33.0

25

0.5

1.0

2.1

5.0

9.0

21.0

32.0

32

0.1

0.2

0.5

1.0

2.0

4.5

7.6

13.0

17.0

25.0

33.0

40

0.2

0.5

0.9

2.2

3.5

6.0

8.0

12.0

14.0

19.0

23.0

33.0

80

0.1

0.2

0.3

0.3

0.5

0.6

0.7

1.0

1.6

2.8

4.4

6.3

11.2

17.5

25.0

34.0

150

0.1

0.2

0.2

0.4

0.7

1.0

1.3

1.7

2.6

5.8

10.4

125

0.1

0.2

0.3

0.4

0.6

1.1

1.7

2.4

3.3

4.3

6.8

15.3

27.0

100

0.1

0.2

0.2

0.3

0.5

0.8

1.3

1.9

3.3

5.2

7.6

10.2

13.4

21.0

65

0.2

0.5

0.7

1.0

1.3

1.7

2.1

2.5

3.5

5.3

8.8

13.8

18.8

32.5

50

0.1

0.3

0.6

1.0

1.8

2.5

3.5

4.5

5.7

7.0

10.0

15.0

26.0

40.0

Nominal diameter of pipe [mm]Flow

Maximum level of immersion for submersible monobloc pumps

IMM. Max* [m] IMM. Max** [m]Model Max. P

Acuaria 07N 3

Acuaria 07N 4

Acuaria 07N 5

Acuaria 07N 6

Acuaria 07N 7

Acuaria 17 5

Acuaria 17 6

Acuaria 27 4

Acuaria 27 6

Acuaria 37 4

Acuaria 37 6

Acuaria 57 4

6

6

12

12

12

12

12

12

12

10

10

10

36

30

80

73

66

70

50

85

67

60

33

70

50

47

102

100

96

50

25

70

45

42

15

52

Maximum level of immersion: Working height + Immersion height < Pression maximum.

* Maximum level of immersion at the maximum performance point in metres.

** Maximum level of immersion at the most unfavourable point in metres.

247

Page 248: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

282

Typical applications

Open well application

1 Pump.

2 Pressure vessel.

3 Pressure switch.

4 Pressure gauge.

5 Isolation valve.

Sump application

1 Pump.

2 Non return valve.

3 Isolation valve.

4 Capacitor box.

8 Power supply cable.

9 Level probes.

10 Level probe cable.

11 Suspension cable.

12 Dry run protection control panel

Model: COMPACT 13.

13 Capacitor box.

Borehole application

1 Pump.

2 Pressure vessel.

3 Pressure switch.

4 Manometer.

5 Isolation valve.

6 Non return vale.

7 Water tight cable joint.

Self priming application

1 Pump.

2 Pressure vessel.

3 Pressure switch.

4 Pressure gauge.

5 Isolation valve.

6 Non return valve.

7 Non return valve and strainer.

8 Floating level switch.

9 Capacitor box.

6 Non return valve.

7 Starter.

8 Capacitor box.

9 Suspension cable.

248

Page 249: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

283

Page 250: Pumps UK Catalogue · 5 UV System Rainsub Rainsub 2AL Accessories Accessories/ Control Panels & Inverters Accessories Accessories Control Panels Q2P Walter Filters Multi Cyclone Filter

284

CA

T 1

00

7U

K 0

2/1

4

ESPA Pumps (UK) Ltd

15-16 Riverside Avenue West

Lawford

Manningtree

Essex

CO11 1UN

Tel +44 1206 391291

Fax +44 1206 391239

www.espa.com

www.espa pumps.co.uk-