PUSH BUTTON INSERTS L SERIES - Ergonomic Partners · DC CIRCUITS Δ WARNING MAKE CERTAIN POWER SUPPLY IS DISCONNECTED BEFORE INSTALLING, REPAIRING, OR WORKING IN THE PROXIMITY OF

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PUSH BUTTON INSERTS L SERIES - Ergonomic Partners · DC CIRCUITS Δ WARNING MAKE CERTAIN POWER SUPPLY IS DISCONNECTED BEFORE INSTALLING, REPAIRING, OR WORKING IN THE PROXIMITY OF
Page 2: PUSH BUTTON INSERTS L SERIES - Ergonomic Partners · DC CIRCUITS Δ WARNING MAKE CERTAIN POWER SUPPLY IS DISCONNECTED BEFORE INSTALLING, REPAIRING, OR WORKING IN THE PROXIMITY OF
Page 3: PUSH BUTTON INSERTS L SERIES - Ergonomic Partners · DC CIRCUITS Δ WARNING MAKE CERTAIN POWER SUPPLY IS DISCONNECTED BEFORE INSTALLING, REPAIRING, OR WORKING IN THE PROXIMITY OF

SP-2-S

DIR

A

A/B

FA

ST

DIR

B PUSH BUTTON INSERTS

SCHEMATIC & OPERATIONAL DIAGRAMS(MULTI-SPEED INSERTS ARE ALL PROGRESSIVE STEP UNLESS SPECIFIED)

PUSH-BUTTON INSERT RATING: 125 VAC, ONE AMP CONTINUOUS PER CONTACTCopyright 2013 by Duct-O-Wire Co.

PRINTED IN U.S.A.

c

SP-1

DIR

AD

IR B

1 - SPEED INSERT2 N.O. CONTACTS

DIR

AD

IR B

1

1

2

2

SP-22 - SPEED INSERT

4 N.O. CONTACTS

DIR

AD

IR B

SP-33 - SPEED INSERT

6 N.O. CONTACTS2 N.C. CONTACTS

L SERIES

DIR

A

DIR

B

DIR

A

DIR

B

A/B

FA

ST

DIR

A

DIR

B

A/B

2N

D

A/B

3R

D

345 Adams Circle

Corona, CA 92882

1351 W. Second Street

Oconomowoc, WI 53066

1445 Norjohn Ct. Unit 10

Burlington, Ontario, Canada L7L 0E6

NOT DESIGNED FORDC CIRCUITS

Δ WARNINGMAKE CERTAIN POWER SUPPLY IS

DISCONNECTED BEFORE INSTALLING,REPAIRING, OR WORKING IN THEPROXIMITY OF ANY ELECTRICAL

SYSTEM. ONLY QUALIFIED ELECTRICALPERSONNEL SHOULD INSTALL OR

REPAIR THESE PRODUCTS.

!

Duct-O-Wire Company reserves the right toalter or amend technical specifications at any

time without notice.

A

B

4 N.O. CONTACTS2 N.C. CONTACTS

DIR

A

DIR

B B

ASP-1-S

INTERLOCKED1 - SPD INSERT

2 N.O. CONTACTS2 N.C. CONTACTS

SUPERCEDES L/PPS 11WL/PPS 13W

INTERLOCKED

Distributed by Ergonomic [email protected]

Tel: (314) 884-8884