Upload
ngoanh
View
214
Download
0
Embed Size (px)
Citation preview
Distrito Industrial Governador Luiz Cavalcante,rua João José Pereira Filho, s/n, Qd. 05, Mód. 11 e 12 s/n, Tabuleiro do Martins | Maceió | Alagoas
+55 82 2122.8600
Soluções em PVC
@tectubo @tectubo @tectubo
FACTORY ADDRESS
deserves this protection.
Installationguide
Your family deserves this protection.
pvc roofing panels
pvc roofing panels®
Your family
A member of
2.30m 2.63m 3.28m 3.94m 4.59m 5.25m
7 8 10 12 14 16
0.84m 0.84m 0.84m 0.84m 0.84m 0.84m
0.90m 0.90m 0.90m 0.90m 0.90m 0.90m
1.93m2 2.21m2 2.76m2 3.31m2 3.86m2 4.41m2
2.30mm 2.30mm 2.30mm 2.30mm 2.30mm 2.30mm
4 4 5 6 7 8
9 9 12 15 18 21
9.2kg 10.5kg 13.1kg 15.8kg 18.4kg 21kg
2.44m 3m 6m
1.30mm 1.30mm 1.30mm
1.20m 1.20m 1.20m
6 7 14
2.85m2 3.51m2 7.02m2
7.6kg 9.4kg 18.7kg
1.17m 1.17m 1.17m
18 18 36
For Tectubo’s full line of products, visit our website:
The Neotelha Fastening Kit includes rubber rings, waterproof caps andself drilling screws. The screws are optimized for metallic surfaces or woodbeams.
PVC ridge cap
Accessories
Fastening kit
Line of products Tectubo
Colonial roofing sheets are manufactured with high-qualityPVC resin. They're lightweight,easy to use, efficient, andwith excellent finish.
Clay
Ivory
Length
Screws (per sheet)
Weight (per sheet)
Thickness
Support (qty. per sheet)
Assembled Width
Width
Coverage Area
Technical Specifications:
Color: White
Corrugated roofing sheets aremanufactured with high-qualityPVC resin. They're lightweight,easy to use, efficient, andwith excellent finish.
Corrugated Panel
PVC roofing panels
By using Neotelha, your overall construction costs will besignificantly reduced in comparison with other roofing materials.You will also benefit from easier installation, reduced waste,reduced roof structure, among other benefits.
Neotelha is eco-friendly and 100% recyclable. Its manufacturingprocess allows for recycling and reuse of industrial waste.
Neotelha prevents the spread of fire and is compliant with theBrazilian fire safety code NBR 15575 - Edifícios Habitacionais- Desempenho.
Neotelha is resistant to extreme weather changes and remainsstable. Its exceptional structural resistance and load bearingcapacity withstand hail, wind gusts and even small animals.
Neotelha embellishes any building and inhibits the growthof fungus, preventing premature ageing and darkening of theroof.
Economy, Convenience, Beauty and Durability are some of theadvantages of using Neotelha.Additional benefits are highlighted below:
Advantages of the NeotelhaPVC roofing panels:
Neotelha PVC sheets are light and reduce installationtime in comparison with other roofing materials.
Neotelha is resistant to chemical and atmospheric agents suchas industrial emissions, sea sprays, acids, and other corrosivesubstances.
Length
Screws (per sheet)
Weight (per sheet)
Thickness
Support (qty. per sheet)
Assembled Width
Width
Modules
Coverage Area
Technical Specifications:
Colors:
Colonial Panel
Assembled length 800mm
PVC ridge end capAssembled length 800mm
PVC verge capAssembled length 1.20m
660 - 710mm
500 - 600mm
The maximum distance between supporting beams must be:Corrugated: 600mm / Colonial: 710mm
COVERAGE
LINE
Outline of the truss and supporting structurefor Neotelha Corrugated PVC roofing sheets.
Outline of the truss and supporting structurefor Neotelha Colonial PVC roofing sheets.
For better fastening, a joist should be used at the ridge.
Corrugated schematic
Colonial schematic
After securing the metal structure with cement, it is important toensure that the surface is flat and with proper spacing;
The solder must conform to each project and material's specificationsand regulations;
The pieces must be level, without visible damage, and their thicknessmust be greater than 25mm (the thickness of rafters/purlins willdepend on the type of truss design selected);
The wood structure must be the correct dimensions, flat, with novisible damage (such as surface cheeks or splits), and treated withprotective finish;
The supporting beams should be 25x60mm (purlins), 40x60mm(rafters) or 60x120mm (depending on clearance). If metal, useU-shape 30x50mm or 40x75mm;
Metal studs must be treated against rust, corrosion, and with a layerof epoxy enamel. Wood beams can be painted, treated with linseed oil,or other waterproofing products;
The first piece must be 70mm away from the edge. The last piece mustbe 100mm away from the ridge.
The wood structure can be fastened with wood screws or nails.
Any metallic structure must be treated against rust;
The truss (metal or wood) must be treated against corrosion and/orwith preservatives. Metal pieces can be soldered and wood can befastened directly;
The minimum pitch for Neotelha PVC gabled roofs is 20 degrees. The productcan be installed vertically as long as the assembly instructions provided arefollowed. For mono-pitched roofs, the minimum pitch shall be 5 degrees.
Pitch
Metal, concrete and wood structures
T
Support
PPE (Personal protective equipment) including: hard hats, goggles,safety belts, gloves and boots.
Do not climb on the roof if it is wet or humid, as it will be too slippery.
Be aware of the power lines.
Keep the area around the roof clear and free of debris.
Always wear a safety belt and line.
Ensure that equipment and tools are properly secured.
Do not step directly on the PVC sheets.
Be careful not to hurt or squeeze your hands and fingers.
The following equipment is required to install Neotelha: plumb line, powerdrill, drill bits, power saw, ruler, square, wrench and sandpaper, as well asall required work safety gear and procedures.
Tools and protective equipment
Installation & safety
FIRSTSUPPORT
20 DEGREE MINIMUM FOR GABLED ROOFS 5 DEGREE MINIMUM FOR MONO-PITCHED ROOFS
Pitch between 20 and 80 degrees.
20 DEGREE MINIMUM FOR GABLED ROOFS 5 DEGREE MINIMUM FOR MONO-PITCHED ROOFS
Pitch between 20 and 80 degrees.
SECONDSUPPORT RIDGE
SECONDTO LASTSUPPORT LAST
SUPPORT
COVERAGE
LINE
FIRSTSUPPORT
SECONDSUPPORT RIDGE
SECONDTO LASTSUPPORT LAST
SUPPORT
660-710mm
500-600mm
Support
Support
Support
Support
Neotelha/TectuboFastening Kit
Neotelha/TectuboFastening Kit
Distance (mm
)
Distance (mm)
Neotelha/Tectubo Fastening Kit
Support
Neotelha/Tectubo Fastening Kit
Panels should always be fastenedat their highest points. Each panelmust be fastened to at least threeplaces as per the models below.
The minimum overlap betweensheets must be:
Corrugated sheets: 150mmColonial sheets: 100mm
For Corrugated sheets, the maximum distance between supporting pointsshould not exceed 500mm.
For Colonial sheets, the maximum distance between supporting pointsshould not exceed 660mm.
Place sheets from the bottom up. Ensure that the bottom sheets are aligned withthe edge of the roof. Start by fastening the bottom part of the sheet and move upaccording to the numeric pattern in the image that follows:
Corrugated panel
Colonial panel
PVC or galvanized steel rain gutters can be used. Steel rain guttersmust have a minimum thickness of 0.6mm and PVC 1.5mm.The width should be 270mm.
Please check to ensure that the bottom and side edges of the roof arestill aligned after installing three or four new sheets, until completion;
When overlapping sheets, a minimum clearance of at least 100mmmust be kept from the edges. The same distance should be kept whenoverlapping the first and second sheets;
The distance between the sheets and the axis of the ridge must notexceed 100mm. If required, sheets can be cut with a power saw;
Sheets must always overlap at their sides and edges. Excess must be cutaway. Before cutting, ensure the edges and sheets are aligned correctly.
An eave overhang of 58cm is recommended for best finishing.Rafters should be spaced 3m apart.
Ridge caps follow the same patterns and designs of the two sheets.They can be installed with the fastening kit;
During installation, the ridge cap must be aligned to the existingsheets. It is usually fastened in three places.
Ridge end caps must be placed at the ends of the ridge. They shouldoverlap the ridge cap by between 100 and 200mm.
Tectubo provides you with this exclusive finishing cap. It must befastened in at least two places.
Ensure that the side sheets are properly positioned and fastened;
Before installing, ensure that the model and size selected willfit your project.
The first step is to pull string lines to define the position and edges of the roof,ridge, rain gutters and required cuts.
Truss Pull string lines Support beams Rain gutters
Installcentral sheets
Installridge cap
Installridge end caps
Adjust surfaces,connections
and joints
Installvalleys and hips
Installside sheets
Installation workflow
String lines Corrugated Profile
Colonial Profile
Eaves
20° ridge cap
Ridge end cap
Rain gutter installation
Placement of the Neotelha PVC sheets
Placement details
Important: Please follow the installation instructions exactly.
Installation