Maintenance Guide Quantum Scalar i 40 and Scalar i 80 6-66548-07 Rev A

Qauntum Scalar i40i80 i4 Maintenance Guide

Embed Size (px)

DESCRIPTION

Maintenance Guide

Citation preview

Page 1: Qauntum Scalar i40i80 i4 Maintenance Guide

Maintenance Guide

Quantum Scalar i40 and Scalar i80

6-66548-07 Rev A

Page 2: Qauntum Scalar i40i80 i4 Maintenance Guide

ii Quantum Scalar i40 and Scalar i80 Maintenance Guide

Scalar i40 and Scalar i80 Maintenance Guide, 6-66548-07 July 2012, Product of U.S.A.

Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.

COPYRIGHT STATEMENT

Copyright 2012 by Quantum Corporation. All rights reserved.

Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.

TRADEMARK STATEMENT

Quantum, the Quantum logo, and Scalar are registered trademarks of Quantum Corporation, registered in the U.S.A. and other countries.

Preserving the World’s Most Important Data. Yours., StorageCare, and Vision are trademarks of Quantum.

LTO and Ultrium are trademarks of HP, IBM, and Quantum in the U.S.A. and other countries. All other trademarks are the property of their respective companies.

Specifications are subject to change without notice.

Page 3: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Preface xixScalar i40 Supported Versions . . . . . . . . . . . . . . . . . . . . . . . xxv

Chapter 1 Common Service Procedures 1

Receiving Customer Library E-mail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Connecting to the Service Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Logging In With Service Privileges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Service Menu Trees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Changing Operator Panel Home Screen View . . . . . . . . . . . . . . . . . . . . 9Changing to Alternate Home Screen. . . . . . . . . . . . . . . . . . . . 11Returning to Default Home Screen . . . . . . . . . . . . . . . . . . . . . 11

Enabling Remote Service Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Logging Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Resetting the Admin Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Shutting Down, Restarting, Turning Off, and Removing Power. . . . . . 14Shutting Down the Library . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Restarting the Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Turning Off the Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Completely Removing Library Power. . . . . . . . . . . . . . . . . . . . 20

Quantum Scalar i40 and i80 Maintenance Guide iii

Page 4: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Emergency Power-off Procedure. . . . . . . . . . . . . . . . . . . . . . . 20

Taking the Library Offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Taking a Partition Online or Offline . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Taking a Tape Drive Online or Offline . . . . . . . . . . . . . . . . . . . . . . . . . 23

Unlocking the I/E Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Releasing Magazines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Releasing Magazines via the User Interface. . . . . . . . . . . . . . . 29Releasing Magazines Manually . . . . . . . . . . . . . . . . . . . . . . . . 30

Configuring the Service Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Saving and Restoring the Library Configuration . . . . . . . . . . . . . . . . . 32Saving the Library Configuration . . . . . . . . . . . . . . . . . . . . . . 33Restoring the Library Configuration . . . . . . . . . . . . . . . . . . . . 33

Removing the Y-tray Restraint and Releasing the Y-tray at Initial Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Installing the Y-tray Restraint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Using Advanced Reporting Control Path Failover and Forced CPF . . . . 38Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Configuring CPF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Forcing CPF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Chapter 2 Lodged Tape Removal Instructions 43

Notes for Service Before Beginning . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Pulling out the Tape Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Rotating the Picker Fingers . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Required Tools and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Taking ESD Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Recovering a Cartridge By Removing the Tape Drive . . . . . . . . . . . . . . 49

Recovering a Cartridge by Removing Top Cover of Library . . . . . . . . . 52Removing the Library from a Rack . . . . . . . . . . . . . . . . . . . . . 53Removing the Lid of the Desktop Kit. . . . . . . . . . . . . . . . . . . . 55Removing the Top Cover of the Library. . . . . . . . . . . . . . . . . . 55Dislodging Tape Using Drive Eject Button (cartridge completely stuck in drive) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

iv Quantum Scalar i40 and i80 Maintenance Guide

Page 5: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Moving the Picker Carriage Along the Robot’s Z-axis (Tape Stuck in Magazine) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Sliding the Picker Along the X-axis (Cartridge Stuck in Drive and Attached to Picker) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Swiveling the Picker (Theta Axis) . . . . . . . . . . . . . . . . . . . . . . . 65Manually Unloading the Tape Drive . . . . . . . . . . . . . . . . . . . . 68Manually Unloading the HP LTO-4 or LTO-5 Half-Height Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Manually Unloading the HP LTO-4 Full-Height Tape Drive. . . . 70Reinstalling the Top Cover and Final Steps . . . . . . . . . . . . . . . 73

Chapter 3 Installing, Removing, and Replacing CRUs 75

Taking ESD Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

Connecting Library Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Installing the Rack Mount Kit (Rail Kit) . . . . . . . . . . . . . . . . . . . . . . . . 79Supported Rack Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Rack Mount Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Installing the Rack Mount Shelves. . . . . . . . . . . . . . . . . . . . . . 81

Installing the Library In a Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

Removing the Library From a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

Installing the Library in a Desktop Kit . . . . . . . . . . . . . . . . . . . . . . . . . 93Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

Removing the Library from a Desktop Kit . . . . . . . . . . . . . . . . . . . . . 101

Removing and Replacing the Front Bezel. . . . . . . . . . . . . . . . . . . . . . 102Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Bezel Replacement Kit Contents . . . . . . . . . . . . . . . . . . . . . . 102Bezel Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . 102

Replacing the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Removing and Installing a Filler Plate . . . . . . . . . . . . . . . . . . . . . . . . 119Removing and Installing a Tape Drive Filler Plate . . . . . . . . . 119

Quantum Scalar i40 and i80 Maintenance Guide v

Page 6: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Removing and Installing a Power Supply Filler Plate . . . . . . . 119

Removing and Replacing a Magazine . . . . . . . . . . . . . . . . . . . . . . . . 121Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Magazine Replacement Kit Contents . . . . . . . . . . . . . . . . . . 121Creating a Backup Map of Cartridge Locations . . . . . . . . . . . 121Removing the Magazine from the Library . . . . . . . . . . . . . . . 122Installing the Magazine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Removing and Installing a Power Supply. . . . . . . . . . . . . . . . . . . . . . 126Replacing a Power Supply in a Single-Power-Supply System (Scalar i40 and Scalar i80). . . . . . . . . . . . . . . . . . . . . . . . . . . 127Adding or Replacing a Redundant Power Supply on the Scalar i80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128

Removing and Replacing the System Control Board . . . . . . . . . . . . . 129Replacing the System Control Board . . . . . . . . . . . . . . . . . . . 129Installing Library Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . 131Restoring the Library Configuration . . . . . . . . . . . . . . . . . . . 133Manually Reconfiguring the Library . . . . . . . . . . . . . . . . . . . 135

Removing and Replacing a Tape Drive. . . . . . . . . . . . . . . . . . . . . . . . 137Preparing Partitions and Control Paths . . . . . . . . . . . . . . . . . 137Removing a Tape Drive from the Library . . . . . . . . . . . . . . . . 138Installing a Tape Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

Packaging the Library for Moving or Shipping. . . . . . . . . . . . . . . . . . 143Packaging Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143Creating a Backup Map of Cartridge Locations . . . . . . . . . . . 143Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144Unpacking the Library in its New Location . . . . . . . . . . . . . . 148

Chapter 4 Installing, Removing, and Replacing FRUs 149

Replacing the Y-tray with Robot . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Y-tray FRU Kit Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Taking ESD Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Removing the Y-tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Installing the Y-tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Packing and Shipping the Removed Y-tray . . . . . . . . . . . . . . 174Moving the Picker Into Proper Position For Shipping . . . . . . 174Swiveling the Picker (Theta Axis) . . . . . . . . . . . . . . . . . . . . . . 175Moving the Picker Along the Robot X-axis . . . . . . . . . . . . . . 178

vi Quantum Scalar i40 and i80 Maintenance Guide

Page 7: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Chapter 5 Getting Information About the Library 181

Viewing Library Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

Viewing System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

Viewing the Location of the Robot . . . . . . . . . . . . . . . . . . . . . . . . . . 183

Viewing the Library Configuration Report . . . . . . . . . . . . . . . . . . . . . 186

Saving and E-mailing the Library Configuration Record. . . . . . . . . . . 188Saving the Configuration Record . . . . . . . . . . . . . . . . . . . . . 189E-mailing the Configuration Record . . . . . . . . . . . . . . . . . . . 189

Viewing the Network Settings Report . . . . . . . . . . . . . . . . . . . . . . . . 190

Viewing the Logged in Users Report . . . . . . . . . . . . . . . . . . . . . . . . . 191

Viewing the All Slots Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192

Viewing, Saving, and E-mailing Library Logs . . . . . . . . . . . . . . . . . . . 193Cleaning Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193Diagnostic Tickets Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194SKM Encryption Key Import Warning Log . . . . . . . . . . . . . . . 194Tape Drive Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195

Viewing Library Information on the Operator Panel . . . . . . . . . . . . . 197Viewing Partition Information. . . . . . . . . . . . . . . . . . . . . . . . 197Viewing Tape Drive Information . . . . . . . . . . . . . . . . . . . . . . 197Viewing Network Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . 198Viewing the Date, Time, and Time Zone . . . . . . . . . . . . . . . . 198Viewing Licenses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

Using Advanced Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199

Chapter 6 Troubleshooting and Diagnostics 201

Capturing Snapshots of Library Information . . . . . . . . . . . . . . . . . . . 202

Troubleshooting Library “Not Ready” Messages . . . . . . . . . . . . . . . . 203“Not Ready” Messages on the Operator Panel . . . . . . . . . . . 203“Not Ready” Messages on the Web Client . . . . . . . . . . . . . . 203

Retrieving Tape Drive Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205

Interpreting LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206System Control Board LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . 207

Quantum Scalar i40 and i80 Maintenance Guide vii

Page 8: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Tape Drive/Sled LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208Power Supply LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

Running the Installation and Verification Test (IVT). . . . . . . . . . . . . . 211

Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213

Running the Random Move Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215

Performing Library Diagnostics Tests . . . . . . . . . . . . . . . . . . . . . . . . . 216Entering the Diagnostics Menu. . . . . . . . . . . . . . . . . . . . . . . 216Resetting a Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 Robotics Get/Put Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218

Resetting Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219

EKM Path Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221Failure Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221Running Manual EKM Path Diagnostics . . . . . . . . . . . . . . . . 222If Failure appears in the Progress Window, the diagnostics were not able to be performed. Enabling Automatic EKM Path Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222

Troubleshooting Diagnostic Ticket Display Issue . . . . . . . . . . . . . . . . 223

Chapter 7 Diagnostic Tickets and Resolutions 225

Ticket Priority Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226

Viewing, Closing, and Resolving Diagnostic Tickets. . . . . . . . . . . . . . 227Viewing Diagnostic Tickets . . . . . . . . . . . . . . . . . . . . . . . . . . 228Closing Diagnostic Tickets Automatically . . . . . . . . . . . . . . . 229

Diagnostic Ticket Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230DT000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231DT001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232DT002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233DT010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234DT011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235DT012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236DT013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237DT014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238DT015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239DT016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240DT017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241

viii Quantum Scalar i40 and i80 Maintenance Guide

Page 9: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

DT018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242DT019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243DT020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244DT021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245DT022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246DT023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247DT024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248DT030 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249DT040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250DT041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251DT042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252DT045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253DT046 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254DT050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255DT051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256DT052 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257DT055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258DT057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259DT058 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260DT059 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261DT060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262DT065 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263DT067 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264DT068 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265DT070 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266DT071 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267DT072 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268DT073 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269DT074 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270DT080 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271DT082 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272DT085 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273DT086 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274DT087 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275DT088 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276DT089 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277DT090 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278DT091 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279DT092 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280DT093 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281DT094 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282DT095 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283DT096 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284

Quantum Scalar i40 and i80 Maintenance Guide ix

Page 10: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

DT097 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285DT101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286DT103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287DT104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288DT105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289DT106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290DT109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291DT112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292DT113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293DT115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294DT116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295DT118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296DT119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297DT120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298DT121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299DT122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300DT123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301DT130 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302DT131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303DT133 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304DT136 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305DT151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306DT153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307DT155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308DT156 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309DT158 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310DT159 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311DT165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312DT166 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313DT167 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314DT170 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315DT171 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316DT172 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317DT173 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318DT174 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319DT175 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320DT176 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321DT177 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322DT178 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323DT179 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324DT180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325DT181 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326DT182 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327

x Quantum Scalar i40 and i80 Maintenance Guide

Page 11: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

DT183 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328DT184 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329DT185 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330DT186 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331DT187 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332DT188 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333DT189 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334DT190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335DT191 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336DT192 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337DT195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338DT196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339

Diagnostic Resolutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340DR000 - Contact Quantum Service . . . . . . . . . . . . . . . . . . . . 340DR001 - PS Power Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340DR002 - PS Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341DR010 - RCS Firmware Image Error. . . . . . . . . . . . . . . . . . . . 342DR011 - RCS Auto-Level Failure. . . . . . . . . . . . . . . . . . . . . . . 343DR012 - RCS Initialization Error. . . . . . . . . . . . . . . . . . . . . . . 344DR013 - RCS Calibration Failure . . . . . . . . . . . . . . . . . . . . . . 345DR014 - RCS Communication Error . . . . . . . . . . . . . . . . . . . . 346DR015 - RCS Move Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . 347DR016 - RCS Motion Failure . . . . . . . . . . . . . . . . . . . . . . . . . 348DR017 - RCS Imager Error . . . . . . . . . . . . . . . . . . . . . . . . . . . 350DR018 - RCS Component Failure. . . . . . . . . . . . . . . . . . . . . . 350DR019 - RCS Put Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351DR020 - RCS Get Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352DR021 - RCS Put Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . 353DR022 - RCS Get Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . 354DR023 - RCS Cartridge Presence . . . . . . . . . . . . . . . . . . . . . . 355DR024 - RCS Cartridge Loss. . . . . . . . . . . . . . . . . . . . . . . . . . 356DR030 - I/E Unlock Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . 357DR031 - I/E Unlock Warning . . . . . . . . . . . . . . . . . . . . . . . . . 358DR040 - VPD Information Missing. . . . . . . . . . . . . . . . . . . . . 359DR041 - VPD Information Warning . . . . . . . . . . . . . . . . . . . . 359DR042 - VPD Information Changed. . . . . . . . . . . . . . . . . . . . 360DR045 - Chassis Component Failure . . . . . . . . . . . . . . . . . . . 361DR046 - Chassis Magazine Unlocked . . . . . . . . . . . . . . . . . . 362DR050 - SCB Hardware Failure . . . . . . . . . . . . . . . . . . . . . . . 363DR051 - SCB Clock Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . 364DR052 - New Library Control Firmware Available . . . . . . . . . 365DR055 - E-Mail Notification Error . . . . . . . . . . . . . . . . . . . . . 365DR057 - Cartridge Inventory Error. . . . . . . . . . . . . . . . . . . . . 366

Quantum Scalar i40 and i80 Maintenance Guide xi

Page 12: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

DR058 - Insert Assignment Warning . . . . . . . . . . . . . . . . . . . 367DR059 - Auto-Cleaning Failure . . . . . . . . . . . . . . . . . . . . . . . 367DR060 - Cartridge Return Failure . . . . . . . . . . . . . . . . . . . . . 368DR065 - Missing Magazine . . . . . . . . . . . . . . . . . . . . . . . . . . 369DR067 - Magazine Unlock Failure . . . . . . . . . . . . . . . . . . . . . 370DR068 - Magazine Unlock Warning . . . . . . . . . . . . . . . . . . . 371DR070 - Missing Cleaning Media . . . . . . . . . . . . . . . . . . . . . 372DR071 - Unknown Cleaning Media . . . . . . . . . . . . . . . . . . . . 372DR072 - Invalid Cleaning Media . . . . . . . . . . . . . . . . . . . . . . 373DR073 - Unassigned Tape Cartridge . . . . . . . . . . . . . . . . . . . 374DR074 - Unlabeled Tape Cartridge . . . . . . . . . . . . . . . . . . . . 375DR080 - Tape Drive Type Changed . . . . . . . . . . . . . . . . . . . . 376DR082 - Tape Drive FW Invalid . . . . . . . . . . . . . . . . . . . . . . . 376DR085 - Drive Removal Unexpected . . . . . . . . . . . . . . . . . . . 377DR086 - Drive Power Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . 378DR087 - Drive Communication Error . . . . . . . . . . . . . . . . . . . 379DR088 - Drive FW Update Failure . . . . . . . . . . . . . . . . . . . . . 380DR089 - Drive Sled Fan Failure . . . . . . . . . . . . . . . . . . . . . . . 381DR090 - Drive Load Failure . . . . . . . . . . . . . . . . . . . . . . . . . . 382DR091 - Drive Unload Failure . . . . . . . . . . . . . . . . . . . . . . . . 383DR092 - Drive Unload Prevented. . . . . . . . . . . . . . . . . . . . . . 384DR093 - Drive Control Failure . . . . . . . . . . . . . . . . . . . . . . . . 385DR094 - Drive Encryption Warning . . . . . . . . . . . . . . . . . . . . 386DR095 - Drive Encryption Failure. . . . . . . . . . . . . . . . . . . . . . 387DR096 - Drive Control Path Loss . . . . . . . . . . . . . . . . . . . . . . 387DR097 - Drive Unload Timeout . . . . . . . . . . . . . . . . . . . . . . . 388DR101 - Drive Tape Alert 1 . . . . . . . . . . . . . . . . . . . . . . . . . . 389DR103 - Tape Drive Alert 3 . . . . . . . . . . . . . . . . . . . . . . . . . . 391DR104 - Drive Tape Alert 4 . . . . . . . . . . . . . . . . . . . . . . . . . . 391DR105 - Drive Tape Alert 5 . . . . . . . . . . . . . . . . . . . . . . . . . . 392DR106 - Drive Tape Alert 6 . . . . . . . . . . . . . . . . . . . . . . . . . . 393DR109 - Drive Tape Alert 9 . . . . . . . . . . . . . . . . . . . . . . . . . . 394DR112 - Drive Tape Alert 12 . . . . . . . . . . . . . . . . . . . . . . . . . 395DR113 - Drive Tape Alert 13 . . . . . . . . . . . . . . . . . . . . . . . . . 396DR115 - Drive Tape Alert 15 . . . . . . . . . . . . . . . . . . . . . . . . . 397DR116 - Drive Tape Alert 16 . . . . . . . . . . . . . . . . . . . . . . . . . 397DR118 - Drive Tape Alert 18 . . . . . . . . . . . . . . . . . . . . . . . . . 398DR119 - Drive Tape Alert 19 . . . . . . . . . . . . . . . . . . . . . . . . . 399DR120 - Drive Tape Alert 20 . . . . . . . . . . . . . . . . . . . . . . . . . 399DR121 - Drive Tape Alert 21 . . . . . . . . . . . . . . . . . . . . . . . . . 400DR122 - Drive Tape Alert 22 . . . . . . . . . . . . . . . . . . . . . . . . . 402DR123 - Drive Tape Alert 23 . . . . . . . . . . . . . . . . . . . . . . . . . 402DR130 - Drive Tape Alert 30 . . . . . . . . . . . . . . . . . . . . . . . . . 404

xii Quantum Scalar i40 and i80 Maintenance Guide

Page 13: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

DR131 - Drive Tape Alert 31 . . . . . . . . . . . . . . . . . . . . . . . . . 405DR133 - Drive Tape Alert 33 . . . . . . . . . . . . . . . . . . . . . . . . . 405DR136 - Drive Tape Alert 36 . . . . . . . . . . . . . . . . . . . . . . . . . 406DR151 - Drive Tape Alert 51 . . . . . . . . . . . . . . . . . . . . . . . . . 407DR153 - Drive Tape Alert 53 . . . . . . . . . . . . . . . . . . . . . . . . . 408DR155 - Drive Tape Alert 55 . . . . . . . . . . . . . . . . . . . . . . . . . 408DR156 - Drive Tape Alert 56 . . . . . . . . . . . . . . . . . . . . . . . . . 409DR158 - Drive Tape Alert 58 . . . . . . . . . . . . . . . . . . . . . . . . . 410DR159 - Drive Tape Alert 59 . . . . . . . . . . . . . . . . . . . . . . . . . 410DR165 - Library Control Path Failover . . . . . . . . . . . . . . . . . . 411DR166 - Library Control Path Warning . . . . . . . . . . . . . . . . . 412DR167 - Library Control Path Failure . . . . . . . . . . . . . . . . . . . 413DR170 - EKM License Expiring. . . . . . . . . . . . . . . . . . . . . . . . 414DR171 - EKM License Expired . . . . . . . . . . . . . . . . . . . . . . . . 415DR172 - EKM Primary Failover. . . . . . . . . . . . . . . . . . . . . . . . 416DR173 - EKM Request Failure . . . . . . . . . . . . . . . . . . . . . . . . 416DR174 - EKM Secondary Failover . . . . . . . . . . . . . . . . . . . . . 418DR175 - EKM Communication Warning . . . . . . . . . . . . . . . . 418DR176 - EKM Mirror Warning . . . . . . . . . . . . . . . . . . . . . . . . 419DR177 - EKM Server Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . 420DR178 - EKM Key Unknown . . . . . . . . . . . . . . . . . . . . . . . . . 421DR179 - EKM Key Set Depleted . . . . . . . . . . . . . . . . . . . . . . . 422DR180 - EKM Software Mismatch . . . . . . . . . . . . . . . . . . . . . 423DR181 - EKM Key Corrupted . . . . . . . . . . . . . . . . . . . . . . . . . 423DR182 - EKM Key Set Exhausted . . . . . . . . . . . . . . . . . . . . . . 424DR183 - EKM Key Set Missing . . . . . . . . . . . . . . . . . . . . . . . . 425DR184 - EKM Key Server Sync Warning. . . . . . . . . . . . . . . . . 426DR185 - EKM Server HTTP Access . . . . . . . . . . . . . . . . . . . . . 427DR186- Resolve EKM Server Key Generation . . . . . . . . . . . . . 428DR187 - EKM Server Certificate Expiring . . . . . . . . . . . . . . . . 428DR188 - Library Certificate Expiring . . . . . . . . . . . . . . . . . . . 429DR189 - Library Certificate Expired . . . . . . . . . . . . . . . . . . . . 430DR 190 - Expiring AR License . . . . . . . . . . . . . . . . . . . . . . . . 430DR 191 - Expired AR License . . . . . . . . . . . . . . . . . . . . . . . . . 431DR 192 - Hitachi License Activation. . . . . . . . . . . . . . . . . . . . 431DR 195 - Media Removal Notification . . . . . . . . . . . . . . . . . . 432DR 196 - Media Security Warning . . . . . . . . . . . . . . . . . . . . . 432

Appendix A Tape Alert Flag Descriptions 435

Quantum Scalar i40 and i80 Maintenance Guide xiii

Page 14: Qauntum Scalar i40i80 i4 Maintenance Guide

Contents

Index 445

xiv Quantum Scalar i40 and i80 Maintenance Guide

Page 15: Qauntum Scalar i40i80 i4 Maintenance Guide

Figures

Figure 1 Service Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Figure 2 Operator Panel Service Menu . . . . . . . . . . . . . . . . . . . . . . . 7

Figure 3 Web Client Service Menu . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Figure 4 Alternate Home Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Figure 5 Shutdown in Progress Message . . . . . . . . . . . . . . . . . . . . 16

Figure 6 Ready to Power Down Message . . . . . . . . . . . . . . . . . . . . 16

Figure 7 Ready to Power Down Message . . . . . . . . . . . . . . . . . . . . 16

Figure 8 Series of Restart Messages . . . . . . . . . . . . . . . . . . . . . . . . 18

Figure 9 I/E Station Unlocked Message. . . . . . . . . . . . . . . . . . . . . . 26

Figure 10 I/E Station Locked Message . . . . . . . . . . . . . . . . . . . . . . . 27

Figure 11 Magazine Unlocked Message . . . . . . . . . . . . . . . . . . . . . . 29

Figure 12 Magazine Locked Timer Message . . . . . . . . . . . . . . . . . . . 29

Figure 13 Magazine Release Latch Access . . . . . . . . . . . . . . . . . . . . 31

Figure 14 Pushing Down on Thumbscrews to Release Y-tray (GA Libraries Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Figure 15 Removing the Y-tray Restraint . . . . . . . . . . . . . . . . . . . . . 37

Figure 16 Setup - Drive Settings Screen . . . . . . . . . . . . . . . . . . . . . . 39

Figure 17 Setup - Control Path Screen . . . . . . . . . . . . . . . . . . . . . . . 40

Quantum Scalar i40 and Scalar i80 Maintenance Guide xv

Page 16: Qauntum Scalar i40i80 i4 Maintenance Guide

Figures

Figure 18 Tools - Drive Operations Screen for CPF . . . . . . . . . . . . . . 41

Figure 19 Force CPF Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Figure 20 Picker Fingers Horizontal, Grasping Cartridge. . . . . . . . . . 46

Figure 21 Picker Fingers Vertical, Releasing Cartridge. . . . . . . . . . . . 47

Figure 22 LTO Tape Cartridge Inspection . . . . . . . . . . . . . . . . . . . . . 51

Figure 23 “Plug” in Magazine Bezel to Allow Access to Thumbscrews . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Figure 24 Top Cover Screw Locations . . . . . . . . . . . . . . . . . . . . . . . . 56

Figure 25 HP LTO-4 Eject Button . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Figure 26 Picker Fingers Horizontal, Grasping Cartridge. . . . . . . . . . 60

Figure 27 Carriage Release Button in Normal Operating Position (Flush With Top of Card). . . . . . . . . . . . . . . . . . . . . . . . . . 61

Figure 28 Depressing the Carriage Release Button . . . . . . . . . . . . . . 62

Figure 29 Acceptable Locations for Sliding the Picker Along the X-axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Figure 30 Normal Position of Theta Gear . . . . . . . . . . . . . . . . . . . . . 66

Figure 31 Raising the Gear to Swivel the Picker . . . . . . . . . . . . . . . . 67

Figure 32 Manual Unload - HP LTO-4 and LTO-5 Half-Height Tape Drive70

Figure 33 Manual Unload - HP LTO-4 Full-Height Tape Drive . . . . . . 72

Figure 34 Connection Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Figure 35 Rack Mount Shelf Depth Requirements . . . . . . . . . . . . . . 82

Figure 36 Assembling the Left and Right Rack Mount Shelves . . . . . 83

Figure 37 Rail Adapter Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

Figure 38 Assembling the Left-Hand Rack Mount Shelf . . . . . . . . . . 85

Figure 39 Installing the Rack Mount Shelves . . . . . . . . . . . . . . . . . . 87

Figure 40 Tightening the Rack Mount Shelves . . . . . . . . . . . . . . . . . 88

Figure 41 Location for Installing the Clip Nut or Cage Nut . . . . . . . . 90

Figure 42 Magazine Release Latch Access Holes . . . . . . . . . . . . . . . . 91

Figure 43 Securing the Scalar i40 and Scalar i80 in the Rack . . . . . . 92

xvi Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 17: Qauntum Scalar i40i80 i4 Maintenance Guide

Figures

Figure 44 Desktop Kit, Scalar i40 and Scalar i80. . . . . . . . . . . . . . . . 94

Figure 45 Magazine Release Latch Access Holes . . . . . . . . . . . . . . . . 96

Figure 46 Location of Rubber Feet on Bottom of Library . . . . . . . . . 98

Figure 47 Installing the side panels . . . . . . . . . . . . . . . . . . . . . . . . 100

Figure 48 Installing the Top Cover . . . . . . . . . . . . . . . . . . . . . . . . . 101

Figure 49 Bezel Screw Locations on Bottom of Library . . . . . . . . . . 104

Figure 50 Bezel Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Figure 51 Scalar i80 Pull/Push Locations . . . . . . . . . . . . . . . . . . . . . 106

Figure 52 Components to Remove . . . . . . . . . . . . . . . . . . . . . . . . . 110

Figure 53 Removing the Y-tray Restraints. . . . . . . . . . . . . . . . . . . . 112

Figure 54 Restraining the Y-tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Figure 55 Reinstalled Components . . . . . . . . . . . . . . . . . . . . . . . . . 117

Figure 56 Filler Plates Installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

Figure 57 Magazine Release Latch Access Holes . . . . . . . . . . . . . . . 123

Figure 58 Proper Orientation (Right-Side Magazine) . . . . . . . . . . . 124

Figure 59 Removing/Installing the Magazine Bezel. . . . . . . . . . . . . 125

Figure 60 Single Power Supply System . . . . . . . . . . . . . . . . . . . . . . 126

Figure 61 Redundant Power Supply System . . . . . . . . . . . . . . . . . . 127

Figure 62 Ethernet Port Locations on the SCB . . . . . . . . . . . . . . . . 131

Figure 63 Acceptable Installation Locations for Full-Height Tape Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140

Figure 64 Installing a Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . 141

Figure 65 Restraining the Y-tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Figure 66 Scalar i40 Packaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . 147

Figure 67 Scalar i80 Packaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

Figure 68 Top Cover Screw Locations . . . . . . . . . . . . . . . . . . . . . . . 154

Figure 69 Y-tray in Packaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155

Figure 70 Bulkhead Inside Library, Y-axis Flex Cable . . . . . . . . . . . . 157

Figure 71 Y-axis Flex Cable Connection on Library Back Plane . . . . 158

Quantum Scalar i40 and Scalar i80 Maintenance Guide xvii

Page 18: Qauntum Scalar i40i80 i4 Maintenance Guide

Figures

Figure 72 Flex Cable on Robot . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159

Figure 73 Y-tray Lift Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

Figure 74 Removing Thumbscrews and Plastic Strips from Bottom of Y-tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162

Figure 75 Y-tray Adapter Board. . . . . . . . . . . . . . . . . . . . . . . . . . . 164

Figure 76 Connecting the Flex Cable . . . . . . . . . . . . . . . . . . . . . . . 164

Figure 77 Strain Relief on Y-tray Adapter Board . . . . . . . . . . . . . . . 165

Figure 78 Strain Relief on Y-tray Adapter Board . . . . . . . . . . . . . . . 166

Figure 79 Y-climber Gear in Proper Position . . . . . . . . . . . . . . . . . . 167

Figure 80 Y-climber Gear in Proper Position and Y-axis Transmission Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

Figure 81 Y-axis Flex Cable Connection on Library Back Plane . . . . 170

Figure 82 Y-axis Flex Cable and Strain Relief Installed on Bulkhead 171

Figure 83 X-axis Encoder on Robot - Front Inside of Library and Robot Directional Movement . . . . . . . . . . . . . . . . . . . . . 173

Figure 84 Normal Position of Theta Gear . . . . . . . . . . . . . . . . . . . . 176

Figure 85 Raising the Gear to Swivel the Picker . . . . . . . . . . . . . . . 177

Figure 86 Acceptable Locations for Sliding the Picker Along the X-axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179

Figure 87 Front Panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206

Figure 88 System Control Board LEDs. . . . . . . . . . . . . . . . . . . . . . . 207

Figure 89 Fibre Channel Tape Drive LEDs . . . . . . . . . . . . . . . . . . . . 209

Figure 90 Power Supply LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

Figure 91 Enabling Automatic EKM Path Diagnostics. . . . . . . . . . . 223

xviii Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 19: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

This manual discusses service-related procedures for the Quantum Scalar® i40 and Scalar i80.

Audience This manual is written for field service engineers.

Document Organization Following is a brief description of chapter contents.

• Chapter 1, Common Service Procedures explains how to perform standard service procedures/

• Chapter 2, Lodged Tape Removal Instructions provides instructions on how to remove a lodged tape cartridge.

• Chapter 3, Installing, Removing, and Replacing CRUs provides detailed instruction on how to install, remove, and replace all the customer-replaceable physical components of the library.

• Chapter 4, Installing, Removing, and Replacing FRUs provides detailed instruction on how to install, remove, and replace all the field replaceable components on the library.

• Chapter 5, Getting Information About the Library describes all of the reporting features on the library.

Quantum Scalar i40 and Scalar i80 Maintenance Guide xix

Page 20: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

• Chapter 6, Troubleshooting and Diagnostics describes the library’s troubleshooting tools, including LEDs and tests.

• Chapter 7, Diagnostic Tickets and Resolutions provides a listing of every diagnostic ticket and resolution available on the library.

• Appendix A, Tape Alert Flag Descriptions lists all the Tape Alerts you may encounter in a diagnostic ticket.

The document concludes with an Index.

Notational Conventions This manual uses the following conventions:

The following formats indicate important information:

Note: Note emphasizes important information related to the main topic.

Caution: Caution indicates potential hazards to equipment or data.

WARNING: Warning indicates potential hazards to personal safety.

• Right side of the system — Refers to the right side as you face the component being described.

• Left side of the system — Refers to the left side as you face the component being described.

Convention Example

File and directory names, menu commands, button names, and window names are shown in bold font.

/data/upload

Menu names separated by arrows indicate a sequence of menus to be navigated.

Utilities > Firmware

xx Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 21: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

Product Safety Statements

Quantum will not be held liable for damage arising from unauthorized use of the product. The user assumes all risk in this aspect.

This unit is engineered and manufactured to meet all safety and regulatory requirements. Be aware that improper use may result in bodily injury, damage to the equipment, or interference with other equipment.

The System, Safety, and Regulatory Information Guide is located on the Scalar i40 and Scalar i80 documentation and training CD.

WARNING: Before operating this product, read all instructions and warnings in this document and in the System, Safety, and Regulatory Information Guide.

Quantum Scalar i40 and Scalar i80 Maintenance Guide xxi

Page 22: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

Related Documents The following Quantum documents are also available for Scalar i40 and Scalar i80 systems:

Document No. Document Title

6-66545-xx Scalar i40 and Scalar i80 User’s Guide

6-66546-xx Scalar i40 and Scalar i80 Quick Start Guide

6-66547-xx Scalar i40 and Scalar i80 Release Notes

6-00618-xx System, Safety, and Regulatory Information

6-66773-xx Scalar i40 and Scalar i80 Basic SNMP Reference Guide

6-00423-xx Quantum Intelligent Libraries SCSI Reference Guide

xxii Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 23: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

For the most up to date product information and documentation, see:

http://www.quantum.com/ServiceandSupport/Index.aspx

SCSI-2 Specification

The SCSI-2 communications specification is the proposed American National Standard for information systems, dated March 9, 1990. Copies may be obtained from:

Global Engineering Documents15 Inverness Way, EastEnglewood, CO 80112(800) 854-7179 or (303) 397-2740

Contacts Quantum company contacts are listed below.

Quantum Corporate Headquarters

To order documentation on the Scalar i40 or Scalar i80 or other products, contact:

Quantum Corporation (Corporate Headquarters)1650 Technology Drive, Suite 700San Jose, CA 95110-1382

Technical Publications

To comment on existing documentation send e-mail to:

[email protected]

6-01317-xx Quantum Intelligent Libraries SMI-S Reference Guide

Document No. Document Title

Quantum Scalar i40 and Scalar i80 Maintenance Guide xxiii

Page 24: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

Quantum Home Page

Visit the Quantum home page at:

http://www.quantum.com

Getting More Information or Help

StorageCare™, Quantum’s comprehensive service approach, leverages advanced data access and diagnostics technologies with cross-environment, multi-vendor expertise to resolve backup issues faster and at lower cost.

Accelerate service issue resolution with these exclusive Quantum StorageCare services:

• Service and Support Web site - Register products, license software, browse Quantum Learning courses, check backup software and operating system support, and locate manuals, FAQs, firmware downloads, product updates and more in one convenient location. Benefit today at:

http://www.quantum.com/ServiceandSupport/Index.aspx

• Telephone Support - Find contact information for your location at: http://www.quantum.com/ServiceandSupport/Contacts/ProductSelect/Index.aspx

• eSupport - Submit online service requests, update contact information, add attachments, and receive status updates via e-mail. Online Service accounts are free from Quantum. That account can also be used to access Quantum’s Knowledge Base, a comprehensive repository of product support information. Sign up today at:

http://www.quantum.com/osr

• StorageCare Guardian - Securely links Quantum hardware and the diagnostic data from the surrounding storage ecosystem to Quantum's Global Services Team for faster, more precise root cause diagnosis. StorageCare Guardian is simple to set up through the internet and provides secure, two-way communications with Quantum’s Secure Service Center. More StorageCare Guardian information can be found at:

http://www.quantum.com/ServiceandSupport/Services/GuardianInformation/Index.aspx

xxiv Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 25: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

Worldwide End-User Product Warranty

For more information on the Quantum Worldwide End-User Standard Limited Product Warranty:

http://www.quantum.com/pdf/QuantumWarranty.pdf

Scalar i40 Supported Versions

Quantum provides support for the current release and the two previous major releases.

For example, since i4 is the latest release, Quantum supports releases i4, i3 and i2. Releases earlier than i2 are not supported.

Quantum Scalar i40 and Scalar i80 Maintenance Guide xxv

Page 26: Qauntum Scalar i40i80 i4 Maintenance Guide

Preface

xxvi Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 27: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1Common Service

Procedures

This chapter explains how to perform common service procedures, including:

• Receiving Customer Library E-mail

• Connecting to the Service Port

• Logging In With Service Privileges

• Service Menu Trees

• Changing Operator Panel Home Screen View

• Logging Out

• Resetting the Admin Password

• Shutting Down, Restarting, Turning Off, and Removing Power

• Emergency Power-off Procedure

• Taking the Library Offline

• Taking a Partition Online or Offline

• Taking a Tape Drive Online or Offline

• Unlocking the I/E Station

• Releasing Magazines

• Configuring the Service Port

• Saving and Restoring the Library Configuration

Quantum Scalar i40 and Scalar i80 Maintenance Guide 1

Page 28: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresReceiving Customer Library E-mail

• Removing the Y-tray Restraint and Releasing the Y-tray at Initial Install

• Using Advanced Reporting Control Path Failover and Forced CPF

Receiving Customer Library E-mail

The following procedures are described in detail in the user’s guide. They are outlined here in case you need to instruct a customer to set up their library e-mail account to automatically send you notifications and snapshots. Please see the user’s guide if you need more details.

• Set the customer contact information (name, phone number, and e-mail address). It is recommended that the customer fill this out before sending automatic e-mail notifications.

From the Web client, click Setup > Notification > Contact Information.

• Configure the library e-mail account to enable the library to send e-mails. You can elect to automatically send a snapshot with the e-mails, and configure authentication, from this screen.

From the Web client, click Setup > Notification > E-mail Account.

• Create, modify, delete, enable, disable, and set priority levels for e-mail accounts (including [email protected]) to receive automatic notifications from the library.

Note: The e-mail account [email protected] is disabled by default and cannot be deleted, although you can modify the priority level.

From the Web client, click Setup > Notification > Setup.

2 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 29: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresConnecting to the Service Port

Connecting to the Service Port

The system control board (SCB) provides an Ethernet port that is reserved for use by service personnel. The service port is the RIGHT side port (see Figure 1 on page 4). The default IP address for the service port is 192.168.177.001.

When servicing a library, connect your laptop to the service port to access the remote Web client (do not use the customer port). Use the Web client when servicing the library. You must use the remote Web client to perform some tasks that are not available on the local operator panel. These tasks include saving and restoring library configurations and downloading firmware.

1 Directly connect your laptop to the service port located on the SCB.

You can connect to the service port using either a cross-over or a straight Ethernet cable.

Note: The service port should never be connected to the LAN infrastructure. The service port should only be direct connected to the service user’s laptop.

2 Open a Web browser on your laptop. Supported browsers include Microsoft® Internet Explorer versions 6.0 and 7.0, and Firefox version 1.0.6 and later.

3 Access IP address 192.168.177.001.

The library login page opens.

Note: If the login page does NOT appear, the customer may have changed the service port subnet because it conflicted with the customer port network subnet. To view the service port IP address, select Tools > Service Network on the operator panel.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 3

Page 30: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresConnecting to the Service Port

Note: In firmware version 100G.GS004, the Tools > Service Network screen on the operator panel displays an incorrect default service port IP address of 192.168.177.000. The correct default IP address is really 192.168.177.1. If the customer changed the subnet (third octet), the final octet will still be 1, even though it displays as 000.

4 Log in to the library.

Figure 1 Service Port

Customer port Service port

4 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 31: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresLogging In With Service Privileges

Logging In With Service Privileges

The service menu is available only to service personnel. There are not too many differences between the service menu and the normal admin menu, except for:

To access the service menu, log on to the operator panel or the Web client using your service name and password.

• Service user name: service

• Service password: 10101100

For security reasons, an administrator can configure the library to prevent a remote service user from logging in through either the Ethernet port or the library service port. This setting is configured only from the operator panel using Setup > Security Services > Service User. You can always log on to the operator panel with service privileges, even when remote service user access is disabled, so you can change this setting if necessary. See Select Exit twice to return to the default home screen. on page 11 for more information.

Operator Panel

• If passwords are enabled, only service users can reset factory defaults (Tools > Reset Factory Defaults).

Web Client • When a service user logs on (either to the Web client or operator panel), all other Web client users are automatically logged off.

• Only service users can Reset Factory Defaults (Tools > Reset Factory Defaults)

• Service users can perform drive and robotics tests without entering Diagnostics mode.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 5

Page 32: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresService Menu Trees

Service Menu Trees

Figure 2 on page 7 shows the operator panel service menu with service items highlighted. Figure 5 on page 16 shows the Web client service menu.

6 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 33: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresService Menu Trees

Figure 2 Operator Panel Service Menu

Setup

Network Configuration

Date & Time

License Installation

Dedicated Slots

Tape Drives (FC)

Configure Partitions

Account Settings

Security Services

Actions

Import Cleaning Tape

Unlock I/E Station

Magazine

Release

Tape Drive

Unload

Change Mode

Manual Cleaning

Reset

Shutdown

Tools

IVT

Diagnostics

Random Move Test

Service Network

Reset Factory Defaults

Reports

Diagnostic Tickets

About Library

Partitions

Network Settings

Date/Time

Licenses

Copyright Statement

Admin Privileges Only

All Users

ACCESS KEY

Operator Panel

Main Menu Bar

I/E

Import Tape

Export Tape

Export Cleaning Tape

Robotics Test

Tape Drive Test

Magazine Test

Library

Tape Drives

Media

Password Settings

Session Timeout

Modify Password*

* Only Available if LUI

Passwords are enabled

NOTE: If passwords are not

enabled on the operator

panel, all users have access

to all menus and functions.

Cleaning

I/E

Network IF

SSH Services

ICMP

Web client

Service User

SNMP V1/V2

SSL

Unload Assist

System Settings

Logical SN Addr

Man Cart Assign

SNMP

SMI-S

Shutdown Library

Restart Library

View Current

Partitions

Auto-Create Partitions

Delete Partitions

Power Save

Modify Subnet

Close ALL

Tape Drives

Robotics View

Change Partition Mode

Alternate Home

Auto DT Close

Quantum Scalar i40 and Scalar i80 Maintenance Guide 7

Page 34: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresService Menu Trees

Figure 3 Web Client Service Menu

Setup

Setup Wizard

Partitions

Cleaning Slots

I/E Station Slots

Advanced Reporting

E-mail Configuration

Drive Settings

Control Path

License

Notification

Diagnostic Tickets

Network Management

Network

SNMP

SNMP Trap

Registrations

User Management

User Accounts

Remote Authentication

Reset Operator Panel

Passwords

Date & Time

Register Library

Operations

Media

Import

Move

Export

Cleaning Media

Export

Import

Partitions

Change Mode

Drive

Unload

Load

Change Mode

I/E Station Unlock

Release Magazines

System Shutdown

Tools

All Diagnostic Tickets

Capture Snapshot

Save/Restore

Configuration

E-mail Configuration

Record

Save Configuration Record

Drive Operations

Download SNMP MIB

Update Library Firmware

Reset Factory Defaults

Reports

System Information

Library Configuration

Network Settings

Logged In Users

All Slots

Log Viewer

Advanced Reporting

Drive Resource

Utilization

Media Integrity Analysis

About

Scalar i40/i80

Open Source Licenses

Log Out

Admin Privileges Only

All Users

ACCESS KEY

Web Client

Main Menu Bar

Encryption

System Configuration

Partition Configuration

EKM Management

Encryption Certificate

Import Communication

Certificates

Encryption Key

Retrieve SKM Logs

Import

Export

Import

Export

Receiver

Addresses

Media Security

Receiver

Addresses

Contact

Information

EKM Path Diagnostics

Services Privileges Only

Drives Robotics

Drive Tests

Drive Reset

Robotics Get/Put Test

8 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 35: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresChanging Operator Panel Home Screen View

Changing Operator Panel Home Screen View

From the operator panel, you may choose to change the default home screen to an alternate home screen that facilitates easy I/E unlock access, displays the number of I/E slots and the number of I/E slots that are full.

Changes to the home screen can be made only from the operator panel.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 9

Page 36: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresChanging Operator Panel Home Screen View

Figure 4 Alternate Home Screen

Number of configured I /E slots

Scalar i80

Number of occupiedI /E slots

Number of configured I/E slots

Unlock I/E Station

Unlock bottom I/E Station

Unlock top I/E Station

Number of occupiedI /E slots

10 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 37: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresEnabling Remote Service Login

Changing to Alternate Home Screen

1 Select Setup > System Settings and press Select.

2 Select Alternate Home and press Modify.

3 Select Up to choose Unlock I/E, and press Apply.

4 Select Exit twice to return to the alternate home screen.

Note: From the alternate home screen, selecting Menu returns you to the default home screen. To return to the alternate home screen, select Actions > Alternate Home, and press Select.

Unlocking the I/E is described in Unlocking the I/E Station on page 25.

Returning to Default Home Screen

1 From the alternate home screen, select Menu to return to the default home screen.

The default home screen is displayed temporarily, however upon power cycle will display the alternate home screen until reset permanently.

2 To reset to view the default home screen permanently, select Setup > System Settings and press Select.

3 Select Alternate Home and press Modify.

4 Select Down and press Apply.

Select Exit twice to return to the default home screen.

Enabling Remote Service Login

For security reasons, a user with administrator privileges can configure the library to prevent the remote service user from logging in through either the Ethernet port or the library service port.

If a customer disabled remote service login, you may need to enable it during your session. Remember to disable it again when you are finished.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 11

Page 38: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresLogging Out

Operator Panel

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Setup > Security Services > Service User.

2 Press Modify.

3 Scroll to select Enabled or Disabled and press Apply.

Logging Out

Remember to log out if you are logged on as service. Logging out secures the library from being accessed by unauthorized users. Log out whenever you have finished accessing the library.

You will only be able to log out of the operator panel if passwords are enabled on the operator panel. To check if passwords are enabled, select Setup > Account Settings > Password Settings on the operator panel.

Note: Clicking the close button (X) in the upper-right corner of the Web client closes the browser window but does not log you out.

Operator Panel

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Actions > Logout.

2 Press Yes to confirm.

12 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 39: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresResetting the Admin Password

Web Client

1 Click the Logout button in the upper right corner of the screen, or select Operations > Log Out.

2 Click OK to confirm.

Resetting the Admin Password

Operator Panel Passwords

If a customer forgets their operator panel passwords and cannot log in, they can reset the passwords. Resetting the passwords disables them and deletes both the admin and user passwords. This means that no login is required to access the operator panel. They can re-create the passwords again as needed.

You can only reset operator panel passwords via the Web client. The customer can do this themselves, logged in with Admin privileges (you do not need to be logged in as Service to do this).

1 From the Web client, select Setup > User Management > Reset Operator Panel Passwords.

2 Press Apply.

Web Client Password

The default customer Admin password is password, but the customer can change it. If they forget what they changed it to, they can either reset factory defaults (which deletes all the user accounts, so they may not wish to do this) or you can reset it for them via the Service login on the Web client.

To change the Admin password, you will change the password the same way a customer would, only via the service menu.

1 Using the Web client, log in as a Service user using the default Service login and password (see Logging In With Service Privileges on page 5).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 13

Page 40: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

2 From the Web client, select Setup > User Management > User Accounts.

3 Select admin and click Modify.

4 In the Enter your Admin Password text box, enter the service password.

5 Enter the new password twice, in the Enter new password for selected user name and Confirm new password for selected user name text boxes.

6 Click Apply.

Shutting Down, Restarting, Turning Off, and Removing Power

It is important to shut down the library properly before turning off the library or completely removing library power.

Caution: You should always perform a shutdown before turning off the library or completely removing power. Otherwise, the following could occur:– The library may not complete closing all data and log files.– If you turn off power or unplug the power cord while writing to tape, the data on the tape could become corrupted.– If you unplug the power cord, the robot may become frozen in the middle of an operation and unable to move once library power is restored, possibly requiring a service call.

The steps for shutting down, turning off, and completely removing library power are:

1 Make sure the connected host applications are not sending commands to the library and that all library operations have stopped.

14 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 41: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

2 Shut down the library using the operator panel or Web client (see Shutting Down the Library on page 15).

3 Turn OFF the library by pressing the power button on the front panel (see Turning Off the Library on page 19).

4 Remove library power by disconnecting the power supply cord from the power supply on the back of the library. If there are two power supplies, remove the cords to both. See Completely Removing Library Power on page 20.

Shutting Down the Library

Shutdown shuts down the library’s operating system and firmware, closes data and log files, and retracts the picker so that a tape cartridge or the picker fingers are not stuck part way into a tape drive or magazine slot. If the robot was in the middle of a get or put operation, it will attempt to complete the operation before shutting down, by either pushing the cartridge into the destination slot, or removing it completely from the slot and stopping in a safe location from which it can move again once power is restored.

Once the shutdown is complete, you can safely turn off the library by pressing the power button on the front panel (see Turning Off the Library on page 19).

Operator Panel

1 Make sure the connected host applications are not sending commands to the library and that all library operations have stopped.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

2 Press Actions > Shutdown > Shutdown Library.

3 Press Yes to confirm.

A “shutdown in progress” message appears on the operator panel (see Figure 5).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 15

Page 42: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

Figure 5 Shutdown in Progress Message

4 Wait until the “ready to power down” message appears (see Figure 6).

Figure 6 Ready to Power Down Message

5 Turn OFF the library by pressing the power button on the front panel.

Web Client

1 Press Operations > System Shutdown.

2 Select Shutdown and click Apply.

3 Click OK to confirm.

4 Wait until the “ready to power down” message appears on the operator panel (see Figure 7).

Figure 7 Ready to Power Down Message

16 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 43: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

5 Turn OFF the library by pressing the power button on the front panel.

Restarting the Library Restart shuts down and then reboots the library's operating system and firmware. During the reboot, the library performs an inventory of the tape drives and magazine slots. If any tape drives or partitions were previously taken offline, restarting the library brings them back online. The reboot takes approximately 5 minutes.

Operator Panel

1 Make sure the connected host applications are not sending commands to the library and that all library operations have stopped.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

2 Press Actions > Shutdown > Restart Library.

3 Press Yes to confirm.

4 Several messages appear on the screen, in the order shown in Figure 8. Do not do anything in response to these messages. The library will restart and initialize on its own.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 17

Page 44: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

Figure 8 Series of Restart Messages

Web Client

1 Make sure the connected host applications are not sending commands to the library and that all library operations have stopped.

2 Press Operations > System Shutdown.

3 Select Restart and click Apply.

4 Press OK to confirm.

5 Several messages appear on the operator panel, in the order shown in Figure 8 on page 18. Do not do anything in response to these messages. The library will restart and initialize on its own.

18 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 45: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

Turning Off the Library Turning OFF the library means pressing the power button on the front panel.

It is recommended that you perform a shutdown via the Web client or operator panel before turning off the library. If you do not perform a shutdown, the library attempts to complete all shutdown operations before turning off the library. However, it may not have enough time to shut down completely, and operations could be stopped mid-process.

Caution: You should always perform a shutdown before turning off the library or completely removing power. Otherwise, the following could occur:– The library may not complete closing all data and log files.– If you turn off power while writing to tape, the data on the tape could become corrupted.

1 Make sure the connected host applications are not sending commands to the library and that all library operations have stopped.

2 Shut down the library (see Shutting Down the Library on page 15).

3 Turn OFF the library by physically pressing the power button on the library’s front panel. It can take up to 12 seconds for the power to completely turn off.

Note: Turning off the library does not completely remove library power (see Completely Removing Library Power on page 20).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 19

Page 46: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresShutting Down, Restarting, Turning Off, and Removing Power

Completely Removing Library Power

Completely removing library power means disconnecting the power cord from each power supply on the library.

Caution: You should always perform a shutdown and then turn off library power before completely removing power. Otherwise, the following could occur:– The library may not complete closing all data and log files.– If you turn off power or unplug the power cord while writing to tape, the data on the tape could become corrupted.– The robot may become frozen in the middle of an operation and unable to move once library power is restored, possibly requiring a service call.

1 Make sure the connected host applications are not sending commands to the library and that all library operations have stopped.

2 Shut down the library (see Shutting Down the Library on page 15).

3 Turn OFF the library by physically pressing the power button on the library’s front panel (see Turning Off the Library on page 19). Make sure the operator panel turns off or the LED on the SCB turns off.

4 Disconnect the power cord(s) from all power supplies on the back of the library. If there are two power supplies, disconnect both cords. Power is completely removed from the library when the LED on each power supply is off.

Emergency Power-off Procedure

In an emergency, you may need to turn off power immediately to stop robot motion, bypassing the normal shutdown process.

In an emergency, you can turn off power in one of two ways:

• Press the power button on the front of the library to turn the library OFF. It may take up to 4 seconds for all motion to completely stop. Note that this does not completely remove library power (you need to disconnect the power cords to do that).

• Disconnect the power cord from each power supply on the back of the library. It may take 1 to 2 seconds for motion to completely stop.

20 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 47: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresTaking the Library Offline

Caution: These methods are not recommended except in case of emergency where it is vital that library operations be stopped immediately. If you do not first perform a shutdown as described in the sections above, the following could occur:– The library may not complete closing all data and log files.– If you turn off power or unplug the power cord while writing to tape, the data on the tape could become corrupted.– If you unplug the power cord, the robot may become frozen in the middle of an operation and unable to move once library power is restored, possibly requiring a service call.

Taking the Library Offline

Some maintenance activities require that the entire library be taken offline. To take the library offline, change the mode of all partitions from online to offline. See Taking a Partition Online or Offline on page 21 for instructions.

Taking a Partition Online or Offline

There are two partition modes: online and offline.

• Online — SCSI hosts control the partition. In this mode, all host application SCSI commands are processed.

• Offline — SCSI hosts cannot control the partition. In this mode, library operations can be performed via the local or remote user interface.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 21

Page 48: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresTaking a Partition Online or Offline

Changing the partition mode changes whether or not the specified partition is online or offline to the host application. Changing a partition mode using the library interface may affect your host application. See your host application documentation for more information.

Note: Some maintenance activities require that the entire library be taken offline. To take the library offline, change the mode of all partitions from online to offline.

When you are changing the partition mode, be aware of the following:

• When you access the Change Partition Mode screen, you will see only partitions to which you have been given access.

• When changing the partition mode from online to offline, all host application commands in progress at the start of the mode change are completed.

You can change partition modes from the operator panel or the Web client.

Operator Panel

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Actions > Change Partition Mode.

The partitions are displayed, along with their online/offline status.

2 Use the Up and Down buttons to select a partition.

3 Press Modify.

4 Uses the Up and Down buttons to change the mode.

5 Press Apply.

22 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 49: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresTaking a Tape Drive Online or Offline

Web Client

1 Select Operations > Partitions > Change Mode.

In the partition table under Mode, the Current column indicates the current mode of the partition. The New column contains an Online/Offline button. The button toggles between modes.

Note: If a partition is in use, the Online/Offline button is grayed out.

2 In the partition table, identify the partition that requires a mode change.

3 Click the Online/Offline button to toggle to the desired mode.

4 Click Apply.

5 Save the library configuration (see Saving the Library Configuration on page 33).

Taking a Tape Drive Online or Offline

There are two tape drive modes: online and offline.

• Online — Tape drive is available for use. This is the normal operating mode for the tape drive.

• Offline — Tape drive is offline to the host application and is not available for cartridge load and unload (move) operations initiated by the host application, but it remains available for Web client or operator panel initiated move commands.

Note: If a cartridge is already in the tape drive when you take the tape drive offline, then the host can still read and write data on the tape.

Some operations require that the tape drive be offline. You can take a tape drive offline rather than the entire library or partition so as to minimize disruption of library operations. A drive taken offline will remain offline until you bring it back online, or until the library is rebooted.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 23

Page 50: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresTaking a Tape Drive Online or Offline

This topic focuses on using the library user interface, not the host application, to change the tape drive mode. Using the library to change tape drive mode may affect the host application. See your host application documentation for more information.

Details on changing the tape drive mode include:

• The online/offline state follows the tape drive slot, not the particular tape drive (if the tape drive were to be moved to a different slot in the library).

• A user with user privileges can select only tape drives in partitions to which they have been given access.

• If you change the mode of a control path tape drive to offline, a caution dialog appears asking you to confirm the mode change.

You can change the tape drive mode from both the operator panel and the Web client.

Operator Panel

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Actions > Tape Drive > Change Mode.

2 Use the Up and Down buttons to select a tape drive.

3 Press Modify.

4 Use the Up and Down buttons to select Online or Offline.

5 Press Apply.

The new mode is displayed.

6 Press Exit.

24 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 51: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUnlocking the I/E Station

Web Client

1 Select Operations > Drive > Change Mode.

The Change Drive Mode screen appears. This screen lists each tape drive’s partition, location, state, current mode, activity, and version.

Note: If more than four tape drives are installed in the library, use the Page 1 of x arrows to view the additional tape drives.

2 Locate the tape drive that you want to take offline or bring online. In the tape drive table under Mode, the Current column indicates the current mode of the partition. The New column contains an Online/Offline button. The button toggles between modes.

3 Toggle the Online/Offline button to the desired mode.

Note: If you change the mode of a control path tape drive to offline, a caution dialog appears asking you to confirm the mode change.

4 Click Apply.

Unlocking the I/E Station

The I/E station is locked during normal library operation. To access the I/E station you must first unlock it. When you give the command to unlock the I/E station, the robot physically moves to the unlock mechanism and unlocks it. This takes a few seconds. Once unlocked, you have 30 seconds to open the I/E station before it locks again.

Opening the I/E station consists of pulling outward on the magazine bezel handle until the magazine stops moving. The magazine will automatically stop when the entire I/E station is exposed.

Note: Because the I/E station is part of the magazine, all storage slots contained in that magazine are unavailable to applications during the time that the I/E station is open.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 25

Page 52: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUnlocking the I/E Station

Note: On the Scalar i80, if you want to open more than one I/E station, such as when importing multiple tape cartridges, unlock and open both I/E stations before you close either of them. Otherwise, if you open and close one at a time, you must wait for the robot to complete inventory on the one being closed before it can open the other one.

Operator Panel

1 If viewing from the default home screen, select Actions > I/E > Unlock I/E Station. If viewing from the alternate home screen, select Unlock.

2 If more than one I/E station is configured on the library, press Unlock for the desired selection.

Note: Only closed I/E stations are listed.

3 Wait until the robot unlocks the I/E station and the screen displays the I/E Station is Unlocked message (see Figure 9 on page 26).

Figure 9 I/E Station Unlocked Message

4 Within 30 seconds, open the I/E station by pulling outward on the magazine bezel handle until the magazine stops moving.

If you do not open the magazine within 30 seconds, it locks and you receive the following failure message.

26 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 53: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUnlocking the I/E Station

Figure 10 I/E Station Locked Message

5 When finished, push the magazine in completely.

The I/E station is now locked.

Web Client

1 Select Operations > I/E Station Unlock.

2 Select the I/E station to unlock and click Apply.

3 Only closed I/E stations are listedClick OK to confirm.

The Progress Window displays. The Progress Window contains information on the action, elapsed time, and status of the requested operation. Do one of the following:

• If Success appears in the Progress Window, the I/E station was unlocked. Click Close to close the Progress Window. The operator panel displays the status Unlocking and then Idle.

• If Failure appears in the Progress Window, the I/E station did not unlock.

4 Within 30 seconds, pull outward on the magazine bezel handle to open the I/E station.

If you do not open the magazine within 30 seconds, it locks.

5 When finished, push the magazine in completely.

The I/E station is now locked.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 27

Page 54: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresReleasing Magazines

Releasing Magazines

Magazines are locked during normal operation. Before you open or completely remove a magazine, you must release it, either via the user interface or manually. These procedures are described in:

• Releasing Magazines via the User Interface on page 29

• Releasing Magazines Manually on page 30

When you give the command to release a magazine via the operator panel or Web client, the robot physically moves to the unlock mechanism and unlocks it. This takes a few seconds. Once unlocked, you have 30 seconds to open the magazine before it locks again.

Note: All storage slots contained in an open or removed magazine are unavailable to applications.

Note: If you want to remove more than one magazine, such as when bulk loading tape cartridges, release and remove all the magazines you want to remove before you close any of them. Otherwise, if you remove and replace them one at a time, you must wait for the robot to complete inventory on the one being replaced before it can release another one.

Caution: If the library is turned ON, always release the magazines via the user interface. It is easier and will not result in a diagnostic ticket (see Chapter 7, Diagnostic Tickets and Resolutions). Additionally, the library makes sure nothing is physically blocking the magazine that could cause damage to library components before allowing you to release it.

28 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 55: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresReleasing Magazines

Releasing Magazines via the User Interface

Use this method when the library is turned ON.

Operator Panel

1 Select Actions > Magazine.

2 Select a magazine and press Release.

Note: Only closed magazines are listed.

3 Wait until the robot unlocks the magazine and the screen displays the Magazine is now unlocked message (see Figure 11 on page 29).

Figure 11 Magazine Unlocked Message

4 Pull outward on the magazine bezel handle to slide the magazine out as far as you wish, or remove it completely. Once you slide the magazine back into the slot all the way, it locks again automatically.

If you do not open the magazine within 30 seconds, it locks and you receive the following failure message.

Figure 12 Magazine Locked Timer Message

Quantum Scalar i40 and Scalar i80 Maintenance Guide 29

Page 56: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresReleasing Magazines

Web Client

1 Select Operations > Release Magazine.

2 Select a magazine and press Apply.

Note: Only closed magazines are listed.

3 Click OK to confirm.

The Progress Window displays. The Progress Window contains information on the action, elapsed time, and status of the requested operation. Do one of the following:

• If Success appears in the Progress Window, the magazine was unlocked. Click Close to close the Progress Window. The operator panel displays the status Unlocking and then Idle.

• If Failure appears in the Progress Window, the magazine did not unlock.

4 Within 30 seconds, pull outward on the magazine bezel handle to slide the magazine out as far as you wish, or remove it completely. Once you slide the magazine back into the slot all the way, it locks again automatically.

If you do not open the magazine within 30 seconds, it locks.

Releasing Magazines Manually

Use this method when the library is turned OFF. If you use this method when the library is turned ON, you will receive a diagnostic ticket.

Caution: If you use the manual method to remove magazine(s) when the library is turned ON you risk a mechanical collision between the magazine and the robotics that could seriously damage components.

1 Insert an opened paperclip, small screwdriver, or other object (3.5 mm or less in diameter that will not break off) into the access hole in the bottom of the magazine bezel (see Figure 13).

2 Use the tool to depress the release latch while gently pulling the magazine bezel handle to slide the magazine out.

30 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 57: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresConfiguring the Service Port

3 If the magazine is on the right side, it will only slide out as far as the I/E station. To release the magazine fully:

• On the Scalar i40 and the bottom right magazine of the Scalar i80, reach under the open magazine and insert the tool directly into the access hole in the library chassis to depress the release latch, while pulling out on the magazine bezel handle.

• On the top right magazine of the Scalar i80, reach under the open magazine and press the release latch directly with your finger, while pulling out on the magazine bezel handle.

Figure 13 Magazine Release Latch Access

Configuring the Service Port

There are two Ethernet ports on the SCB. The left port is for customer use for remote access via the Web client, and the right port is for service use only. The default service port IP address is 192.168.177.1.

You should never change the service port subnet unless it happens to conflict with the subnet configured for the customer port. Incorrectly setting the service port subnet could impact connectivity of the customer port and network traffic attached to the customer port, even when the service port is disconnected. If there is a subnet conflict the customer must change the service port subnet to avoid ambiguity between the two interfaces.

Magazine release latch access holes

Quantum Scalar i40 and Scalar i80 Maintenance Guide 31

Page 58: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresSaving and Restoring the Library Configuration

The instructions below explain how to change the IP address on the service port. You can only change the subnet (third octet) of the IP address: 192.168.xxx.1. The other sections must remain as they are. You may choose a number from 1 to 255.

You can only configure the service network from the operator panel.

Operator Panel

1 Select Tools > Service Network.

Under “Modify Subnet” the three-digit octet of the subnet is highlighted.

2 Use the Left and Right buttons to select a digit to modify. Use the Up and Down buttons to select a value for the digit.

Note: When you press the Right button to the third digit, its function changes to Apply.

3 When you finish making changes, press the Right button until its function changes to Apply, then press Apply.

4 Press OK.

5 Save the library configuration (see Saving the Library Configuration on page 33).

Saving and Restoring the Library Configuration

The library has many configurable items, such as tape drive IDs, partitions, user accounts, import/export (I/E) stations, and cleaning slots. In the event of a hardware failure or firmware upgrade, the save and restore operations can be used to restore the library's configurable items to a previous state. The save/restore operation also saves and restores library firmware and license keys installed on the library.

32 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 59: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresSaving and Restoring the Library Configuration

Note: The save/restore operations should not be performed concurrently by multiple administrative users logged in from different locations. You can access the screens, but you cannot apply changes while another administrative user is performing the same operation.

Saving the Library Configuration

This operation saves your current library configuration and library firmware.

It is recommended that you save the library configuration after modifying a configurable item and before upgrading firmware. This allows you to restore the most current settings if necessary.

Save your library configuration when it is in a known working state. In the event of a hardware failure, the saved configuration can be used to restore the configuration after hardware repairs are made.

Before initiating a firmware upgrade, you should save the library configuration. You then have the option to restore the configuration after either a successful or an unsuccessful upgrade.

You can only save the configuration from the Web client.

Web Client

1 Select Tools > Save/Restore Configuration.

2 Select Save System Configuration.

3 Click Apply.

4 When the operation completes successfully, complete the next screens to save the file to a known location.

Restoring the Library Configuration

You can restore the library’s configurable items to a previous state using a saved configuration file. If you updated the library firmware since last saving the configuration, the library automatically restores the library firmware to the version that was saved with the configuration.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 33

Page 60: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresSaving and Restoring the Library Configuration

Caution: After you restore the library’s configuration, verify that your drive firmware version reflects the desired firmware level.

Note: You can also downgrade library firmware to an earlier version using the Tools > Update Library Firmware command. Note that you will lose all your current library configuration information except for network settings, date and time, and license keys. You can restore the other configurable items using a configuration file that was saved when the earlier version of library firmware was installed on the library, or you can reconfigure your library’s settings.

You can only restore the library configuration via the Web client.

Web Client

1 Select Tools > Save/Restore Configuration.

2 Select Restore System Configuration.

3 Click Apply.

4 Use the next screens to browse to the saved configuration file and upload it to the library.

This operation saves your current library configuration and library firmware.

5 Verify the drive firmware level, and if necessary, manually upgrade to desired firmware level.

34 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 61: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresRemoving the Y-tray Restraint and Releasing the Y-tray at Initial Install

Removing the Y-tray Restraint and Releasing the Y-tray at Initial Install

When you install a new library, the Y-tray is restrained at the top of the library. If the Y-tray has problems initializing upon initial install or after a chassis replacement, it may be because the Y-tray restraint was not removed and/or the Y-tray was not released fully.

Note: After the initial unpack, if you need to secure the Y-tray again, you will restrain the Y-tray at the bottom of the library, not the top.

Note: Step 1, Step 2, and Figure 14 only apply to libraries with GA firmware (100G.GS004). Later versions of firmware do not require these steps to be performed.

The Y-tray restraint consists of four (4) thumbscrews, a plastic sheet, a small metal clip, and underneath the plastic sheet, an orange restraint tab—located on the top cover of the library.

1 GA Libraries Only: Partially unscrew (about 3 or 4 turns) all four thumbscrews, but do not remove them.

2 GA Libraries Only: Using your fingers, carefully push down on two diagonally positioned thumbscrews. Push them down as far as they will go. This ensures that the Y-tray can initialize freely. See Figure 14.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 35

Page 62: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresRemoving the Y-tray Restraint and Releasing the Y-tray at Initial Install

Figure 14 Pushing Down on Thumbscrews to Release Y-tray (GA Libraries Only)

3 Completely unscrew and remove the four thumbscrews from the top cover (see Figure 15). Save the thumbscrews in case you need to move or ship the library in the future.

Note: The Y-tray may stay at the top of the library, or it may move downward toward the floor of the library. If it moves downward, you will hear the gears turning as it moves. This is normal.

4 Remove the plastic sheet and metal clip and discard. You will not need to use them again.

5 IMPORTANT: Remove the orange shipping restraint tab and discard. You will not need to use it again.

Push down on two diagonally positioned thumbscrews

36 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 63: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresInstalling the Y-tray Restraint

Figure 15 Removing the Y-tray Restraint

6 After the library has been installed and is ready to be powered up, refer to Running the Installation and Verification Test (IVT) on page 211.

Installing the Y-tray Restraint

To restrain the Y-tray for moving or shipping the library, you place the library on its side and secure the Y-tray to the bottom of the library using 4 thumbscrews. If the customer does not have the thumbscrews and library packaging left over from the initial unpack, they will need to order a packaging CRU from Quantum. The packaging and Y-tray restraint procedure is described in detail in Packaging the Library for Moving or Shipping on page 143.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 37

Page 64: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUsing Advanced Reporting Control Path Failover and Forced CPF

Caution: Do not set the library upright while the thumbscrews are installed. The Y-tray must be on its side or in its specific packaging, otherwise the thumbscrews could damage the chassis or the Y-tray.

Using Advanced Reporting Control Path Failover and Forced CPF

If an HP LTO-5 FC tape drive is the control path for a partition, you can select another HP LTO-5 FC tape drive in that partition for control path failover. This means that if the control path tape drive fails, the failover tape drive becomes the control path for the partition. The failed-over tape drive remains the control path for the partition unless it fails or the library is restarted. When either of these events occurs, the library starts over and attempts to use the original control path tape drive as the control path, and the original failover tape drive for failover.

The control path and failover tape drives are assigned by location in the library, so even if you replace a tape drive with another HP LTO-5 FC tape drive, the library will still fail over or revert to the specified location.

Prerequisites To configure control path failover, you must have the following setup on your library:

• Advanced Reporting License.

• The control path and failover tape drives must both be HP LTO-5 FC tape drives, and you must have a minimum of two drives in a single partition.

• The control path and failover tape drives must have their topology configured as Point to Point.

• The control path and failover tape drives must be connected to an NPIV-enabled switch on the same fabric.

38 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 65: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUsing Advanced Reporting Control Path Failover and Forced CPF

When control path failover is configured for a partition, the partition uses a virtual port as the control path communication port. The World Wide Port Name (WWPN) for this virtual port is listed in the library’s System Information Report in the Library Partitions section under Control Path (see Viewing System Information on page 182).

Configuring CPF You can configure control path failover from the Web client only.

Web Client

1 Setup the drive topology.

Set the topology for the control path and control path failover tape drives to Point to Point. For more information on configuring tape drive parameters, refer to the user’s guide.

a Select Setup > Drive Settings.

The Setup - Drive Settings screen displays.

Figure 16 Setup - Drive Settings Screen

Quantum Scalar i40 and Scalar i80 Maintenance Guide 39

Page 66: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUsing Advanced Reporting Control Path Failover and Forced CPF

b For the appropriate partition, select the Requested Topology of Point to Point from the drop down menu.

c Click Apply.

2 Select Setup > Control Path.

The Control Path screen displays for that partition.

Figure 17 Setup - Control Path Screen

3 Select the Failover drive by clicking the Failover option.

4 Click Apply.

You can also manually force a failover (see Forcing CPF on page 41).

40 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 67: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUsing Advanced Reporting Control Path Failover and Forced CPF

Forcing CPF Web Client

You can manually force a control path failover. You might want to force a failover to check that the control path on the non-active tape drive is operational, or to switch back to the original control path tape drive once the issue that originally caused the failover has been fixed.

1 Click Tools > Drive Operations.

The Tools - Drive Operations screen displays.

Figure 18 Tools - Drive Operations Screen for CPF

2 Select Force Control Path Failover and click Next.

The Force Control Path Failover screen displays (see Figure 19 below). All of the partitions that have control path failover enabled are listed. The location and status of the tape drive that is currently serving as the control path are listed in the Active columns. The location and status of the tape drive that is currently serving as the standby control path are listed in the Standby columns. For each partition, the following information is listed:

Column Indicates

Active Drive Location of the current control path tape drive.

Active Status Ready status of the current control path tape drive.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 41

Page 68: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 1: Common Service ProceduresUsing Advanced Reporting Control Path Failover and Forced CPF

Figure 19 Force CPF Screen

3 Select the partition on which you want to force the failover, and click Apply.

Note: The standby tape drive must be “ready” and “connected” in order to force a failover.

4 Click Apply.

The new active tape drive location displays in the Active Drive column. The new standby tape drive location displays in the Standby Drive column.

Note: If the new tape drive locations do not display, refresh the browser.

Active Connected Whether the current control path tape drive is connected and has a working link.

Standby Drive Location of the standby tape drive.

Standby Status Ready status of the standby tape drive.

Standby Connected

Whether the standby tape drive is connected and has a working link.

Column Indicates

42 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 69: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2Lodged Tape Removal

Instructions

The lodged tape procedure is designed to be performed by a customer, but ONLY with a service technician on the phone with them guiding them through it. You must first send the customer a copy of this procedure, which they can follow with you on the phone helping them. The procedure is released in Agile as a standalone document named Scalar i40 and Scalar i80 Lodged Tape Removal Instructions (p/n 6-66780-xx).

• Notes for Service Before Beginning

• Pulling out the Tape Drive

• Rotating the Picker Fingers

• Recovering a Cartridge By Removing the Tape Drive

• Recovering a Cartridge by Removing Top Cover of Library

• Moving the Picker Carriage Along the Robot’s Z-axis (Tape Stuck in Magazine)

• Sliding the Picker Along the X-axis (Cartridge Stuck in Drive and Attached to Picker)

• Swiveling the Picker (Theta Axis)

• Manually Unloading the HP LTO-4 or LTO-5 Half-Height Tape Drive

• Manually Unloading the HP LTO-4 Full-Height Tape Drive

• Reinstalling the Top Cover and Final Steps

Quantum Scalar i40 and Scalar i80 Maintenance Guide 43

Page 70: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsNotes for Service Before Beginning

Notes for Service Before Beginning

Make sure to send the customer a copy of Scalar i40 and Scalar i80 Lodged Tape Removal Instructions (Agile p/n 6-66780-xx) and then walk them through the process.

Caution: The procedure that follows is complex and may potentially expose you to electrical current or contact with the robotic arm if not performed correctly.

A lodged tape video complementing this guide is available. Quantum strongly encourages you to review the video before attempting to complete this procedure. Go to http://csweb.quantum.com/training/i40i80/stuck_tape/Scalar_i40i80_stuckTapeRemoval.html

In addition to the lodged tape removal instructions, Service technicians should know the following two things regarding Pulling out the Tape Drive and Rotating the Picker Fingers. We don’t provide them to customers because it is rare that you will need to use them. However, it is important that you know about them in case they come up.

Pulling out the Tape Drive

We don’t mention this in the “lodged tape removal” standalone document, but it may come up. Be aware of this if you are guiding a customer in pulling out a tape drive.

Normally, pulling out the tape drive will not damage anything. If the cartridge is stuck in the tape drive, the picker fingers should not be engaged, and if they are engaged, then the tape will not be lodged in the drive. However, in rare cases, the picker and drive will both remain attached when you try to pull out the tape drive. Therefore, if you experience a lot of resistance when pulling out the tape drive, you should stop and instead remove the library top cover.

What is “a lot” of resistance?

44 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 71: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsNotes for Service Before Beginning

There is a normal amount of resistance when the tape drive disconnects from the connector in the library. This should go away after you pull the drive out 1/4 of an inch. If there is undue resistance after 1/4 of an inch, then you should stop pulling out the tape drive. You will need to help the customer gauge what this feels like.

Rotating the Picker Fingers

You should not need to do this very often. However, you may need to do this as a last resort to remove a cartridge.

If a cartridge is jammed into a magazine slot and is still being held by the picker, and you cannot move the cartridge by lifting it up or moving the picker along the Z-axis as described in the Moving the Picker Carriage Along the Robot’s Z-axis (Tape Stuck in Magazine) on page 60, then you may need to rotate the fingers down to enable you to move the picker out of the way.

The picker arms rotate 90 degrees. When the picker “fingers” are horizontal, they face in toward the tape cartridge, grasping the notch in the cartridge (see Figure 20). When they face straight down, they release the tape cartridge (see Figure 21). When you rotate one arm, the other rotates with it.

To release the tape cartridge:

1 Rotate the picker arms down by turning one of the picker finger drive gears upward. The picker finger drive gears are located on both sides of the picker (see Figure 20 and Figure 21).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 45

Page 72: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsNotes for Service Before Beginning

Figure 20 Picker Fingers Horizontal, Grasping Cartridge

Picker finger drive gear

46 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 73: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsNotes for Service Before Beginning

Figure 21 Picker Fingers Vertical, Releasing Cartridge

2 Once the picker arms are pointing down, you can try to push the cartridge back into the slot, or move the picker away and then removing the cartridge.

Picker finger drive gear, rotate upward

Picker finger points downward, out of cartridge

Quantum Scalar i40 and Scalar i80 Maintenance Guide 47

Page 74: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRequired Tools and Equipment

Required Tools and Equipment

• Small Phillips screwdriver

• Small flat-head screwdriver

• Large flat-head screwdriver

• 6 mm or 0.25 inch socket or nut-spinner (for manually unloading the HP LTO-4 or LTO-5 half-height tape drive)

• T-6 or T-8 Torx driver, depending on model (for manually unloading the HP LTO-4 or LTO-5 half-height tape drive)

• T-10 Torx driver (for manually unloading the HP LTO-4 full-height tape drive)

Taking ESD Precautions

See Taking ESD Precautions on page 76.

Procedure

1 Verify that the library is running the latest firmware. If necessary, download the latest library firmware to a known location on your computer. To see a listing of the most current library firmware, go to: http://www.quantum.com/ServiceandSupport/SoftwareandDocumentationDownloads/SI40/Index.aspx and click the Firmware tab.

2 Power cycle the library (from the operator panel, select Actions > Shutdown > Restart Library). When the library comes ready, check to see if the problem is resolved. If not resolved, continue to next step.

48 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 75: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge By Removing the Tape Drive

3 Open any diagnostic tickets and follow the resolution steps (from the Web client, click Tools > All Diagnostic Tickets). If the problem is still not resolved, continue to next step.

4 Look at the ticket details and take note of the source, destination, and location of the lodged cartridge, if listed.

5 Do one of the following:

• If the cartridge is stuck in a tape drive, go to Recovering a Cartridge By Removing the Tape Drive on page 49.

• If the cartridge is stuck in a magazine slot, or if there is no indication where the cartridge is stuck, go to Recovering a Cartridge by Removing Top Cover of Library on page 52.

Recovering a Cartridge By Removing the Tape Drive

1 Shut down and turn off the library.

a From the operator panel, select Actions > Shutdown > Shutdown Library.

b When the operator panel indicates it is “ready to power down,” turn OFF the library by pressing the power button on the front panel.

2 Remove the affected tape drive from the library, as follows:

aDisconnect the cable from the back of the tape drive.

b Unscrew the captive thumbscrews from the tape drive’s back plate. A half-height tape drive has two thumbscrews; a full-height tape drive has four.

c Using the drive sled handle, pull the tape drive out of the library and place it on a flat, stable surface.

3 Take one of the following actions, according to the scenarios in the table below.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 49

Page 76: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge By Removing the Tape Drive

Caution: Do not stick your hands into the library through the tape drive slot opening. You could hurt yourself on sharp edges or damage the Y-tray.

IF the tape cartridge... THEN do this

Falls to the floor of the library

1 Remove the top cover of the library For instructions, see Recovering a Cartridge by Removing Top Cover of Library on page 52.

2 Reach in and take out the fallen cartridge.

Remains in the picker

1 Remove the top cover of the library to access the cartridge. For instructions, see Recovering a Cartridge by Removing Top Cover of Library on page 52

2 Try to remove the tape cartridge by lifting up on it slightly to disengage it from the picker fingers.

3 if the cartridge is partially in the slot, slide the picker carriage along the X-axis. For instructions, see Sliding the Picker Along the X-axis (Cartridge Stuck in Drive and Attached to Picker) on page 63.

Remains in the tape drive

If you can easily remove the tape cartridge with your fingers, do so. Inspect the cartridge per Figure 22 on page 51. If the cartridge passes the inspection, you can re-import into the library later. If you cannot easily remove the cartridge with your fingers, or if it is completely seated in the tape drive, do the following: 1 Reinsert the drive sled and secure the thumb screws

to the back of the library. 2 Remove the top cover of the library. See Removing

the Top Cover of the Library on page 55.3 Dislodge the tape using the drive’s Eject button.

Refer to Dislodging Tape Using Drive Eject Button (cartridge completely stuck in drive) on page 57.

50 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 77: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge By Removing the Tape Drive

atch.

Figure 22 LTO Tape Cartridge Inspection

4 Reinstall the tape drive back in the library and tighten the thumbscrews.

5 Turn ON the library by pressing the power button on the front panel. Wait for the library to initialize.

6 Run the tape drive diagnostic test on any tape drives you removed and reinstalled to be sure they are functioning correctly.

a Install a scratch tape in the top I/E station slot.

b If manual cartridge assignment is enabled, assign the scratch tape to the System partition.

c From the operator panel, select Tools > Diagnostics.

d Continue through the next few screens to run the tape drive test on the replaced tape drive.

7 Re-import the tape cartridge back into the library, if desired. For instructions, see the Scalar i40 and Scalar i80 User’s Guide.

CartridgeInspect the exterior of the cartridge for chips, cracks, dents or missing screws. Gently shake the cartridge, listening for rattles or loose pieces.

Cartridge Hub/Reel LocksConfirm that the spring-loaded hub on the bottom of the cartridge is centered. Press the hub. It should spring back if operating properly. Operation of the reel locks may release the hub and re-center. Check that the reel locks are visible and out. The Hub should not turn.

Write Protection SwitchMove the switch. It should beable to snap into write-protected mode and write-enabled mode.

Cartridge DoorEnsure the door is moveableand springs closed. Check ththe leader pin is visible at eaend and snapped into place

Quantum Scalar i40 and Scalar i80 Maintenance Guide 51

Page 78: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Recovering a Cartridge by Removing Top Cover of Library

Perform this procedure when the picker is jammed and/or the tape cartridge is lodged in a slot or tape drive and you cannot get it out by removing a tape drive. The procedure is as follows:

1 Remove the library from a rack or remove the lid of a desktop kit, following one of these procedures:

• Removing the Library from a Rack on page 53

• Removing the Lid of the Desktop Kit on page 55

2 Remove the top cover of the library, following Removing the Top Cover of the Library on page 55.

3 Perform one or more of the below procedures to dislodge the cartridge or move the picker.

• Dislodging Tape Using Drive Eject Button (cartridge completely stuck in drive) on page 57.

• Moving the Picker Carriage Along the Robot’s Z-axis (Tape Stuck in Magazine) on page 60

• Sliding the Picker Along the X-axis (Cartridge Stuck in Drive and Attached to Picker) on page 63

• Swiveling the Picker (Theta Axis) on page 65

4 When you have successfully removed the cartridge, perform Reinstalling the Top Cover and Final Steps on page 73.

52 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 79: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Removing the Library from a Rack

If the library is installed in a rack, you will need to remove it as follows:

WARNING: Two people are required to safely lift the library into and out of a rack. With two half-height tape drives and no cartridges installed, the Scalar i40 weighs approximately 44 lbs. (20 kg). With two full-height tape drives and no cartridges installed, the Scalar i80 weighs approximately 66 lbs. (30 kg). With more drives and cartridges, the library weighs significantly more.

1 Look at the diagnostic ticket to see where the lodged cartridge is located.

2 Remove the non-affected magazines from the library (to reduce weight). If you cannot determine which magazine contains the lodged cartridge, skip this step.

a Label the magazines so you can reinstall them in the same slots later.

b From the operator panel, select Actions > Magazine.

c Select a non-affected magazine and press Release.

d When the operator panel displays the message “Magazine is now unlocked,” remove the magazine. Carefully place the magazine on a flat, stable surface so that the cartridges do not fall out.

e Repeat the above steps for the remaining non-affected magazines.

3 Shut down and turn off the library.

a From the operator panel, select Actions > Shutdown > Shutdown Library.

b When the operator panel indicates it is “ready to power down,” turn OFF the library by pressing the power button on the front panel.

4 Disconnect all cords and cables from the back of the library (power supplies, SCB, and tape drives). If you have multiple tape drives, label the cables so you can re-connect them properly later.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 53

Page 80: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

5 Remove all the tape drives from the back of the library (to reduce weight). Label the tape drives before you remove them so you can reinstall them in the same locations later.

a Unscrew the captive thumbscrews from the tape drive’s back plate. A half-height tape drive has two thumbscrews; a full-height tape drive has four.

b Using the drive sled handle, pull the tape drive out of the library and place it on a flat, stable surface.

6 Gain access to the captive thumbscrews securing the library to the rack. The thumbscrews are visible for any magazines you removed. For magazines that you did not remove, the captive thumbscrew sits behind the magazine bezel. Use your fingernail or a small, flat-head screwdriver or other similar implement to remove the “plug” in the magazine bezel located in front of the thumbscrew. See Figure 23.

Figure 23 “Plug” in Magazine Bezel to Allow Access to Thumbscrews

7 Use a large, flat-head screwdriver to loosen the captive thumbscrews

on the front of the library that secure the library to the rack.

54 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 81: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

8 Slide the library out of the rack and place it on a flat, level, stable surface.

Caution: Do not tip the library side to side. If you do, cartridges could spill out into the interior of the library and cause damage.

Removing the Lid of the Desktop Kit

If the library is installed in a desktop kit, do the following:1 Turn OFF the library by pressing the power button on the front panel.

Wait until the SCB LED turns off.2 Disconnect the power cord from the power supply on the back of the

library.3 Remove the lid of the desktop kit. Unscrew two Phillips screws from

the back of the library and set aside. Slide the cover of the desktop kit toward the back of the library until it slides off.

Removing the Top Cover of the Library

1 Using a small Phillips screwdriver, remove the 24 screws that secure the top cover to the library (10 on top and 7 on left and right sides; see Figure 24). Set the screws aside.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 55

Page 82: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Figure 24 Top Cover Screw Locations

2 Lift the top cover off of the library.

Ten screws on top

Seven screws on each side

56 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 83: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Dislodging Tape Using Drive Eject Button (cartridge completely stuck in drive)

Before trying to remove a cartridge manually, attempt to dislodge the tape using the following procedure:

Note: Depending on the state of the drive and/or library, you may not be able to successfully dislodge the tape using the drive’s Eject button.

1 Ensure the library is on a flat surface by a power source and the top cover has been removed.

2 Connect the library to a power source, and power on the library.

If the library needs to be moved to a power source, put on the top cover to provide chassis support.

Caution: The procedure that follows is complex and may potentially expose you to electrical current or contact with the robotic arm if not performed correctly.

A lodged tape video complementing this guide is available. Quantum strongly encourages you to review the video before attempting to complete this procedure. Go to http://csweb.quantum.com/training/i40i80/stuck_tape/Scalar_i40i80_stuckTapeRemoval.html

3 Wait for initialization to complete and any robotic movement to cease. This takes about 15 minutes.

If initialization is not completed successfully, you will receive a diagnostic ticket which will need to be resolved before continuing.

4 Visually determine which drive has a stuck tape.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 57

Page 84: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

5 Press the drive’s Eject button using a non-conductive tool, like a pencil eraser or a plastic pen top.

Note: You may have to move the Y-tray to access the Eject button. Refer to Moving the Y-tray to Bottom of Library on page 59.

Figure 25 HP LTO-4 Eject Button

6 If tape ejects successfully, you are done. If it does not eject, shut down the library and refer to Manually Unloading the Tape Drive on page 68.

HP LTO-4 Eject button

58 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 85: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Moving the Y-tray to Bottom of Library

If the Y-tray is above the drive with the stuck tape and as a result, the Eject button is not exposed, attempt to move the Y-tray to the bottom of the library using I/E Unlock.

1 Unlock the I/E station from the operator panel.

a Select Actions > I/E > Unlock I/E Station.

b If more than one I/E station is configured on the library, select the bottom I/E station to unlock, and press Unlock.

Note: Only closed I/E stations are listed.

c Wait until the robot unlocks the I/E station and the screen displays the “I/E Station is Unlocked” message.

2 Press the drive’s Eject button.

3 If the tape ejects successfully, push in the magazine and you are done. If it does not eject, shut down the library and refer to Manually Unloading the Tape Drive on page 68.

If the Y-tray is unable to move to bottom of library, do the following:

1 If the robot is parked in front of drive, manually slide the robot towards the front (away from the drive) until the Eject button is visible.

2 Press the drive’s Eject button.

Note: This may require you to access the Eject button from below the Y-tray by placing your hand beneath the Y-tray.

3 If the tape ejects successfully, you are done. If it does not eject, shut down the library and refer to Manually Unloading the Tape Drive on page 68.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 59

Page 86: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Moving the Picker Carriage Along the Robot’s Z-axis (Tape Stuck in Magazine)

If the picker failed while pulling a cartridge out of a slot and the cartridge is still partially seated in the magazine slot, you may need to manually move the picker carriage farther out from the slot along the toothed gears (Z-axis) on the picker.

1 Ensure the library is turned off and unplugged from the power source.

2 Make sure the picker fingers are horizontal (pointing toward each other, as when gripping a cartridge), as shown in Figure 26. You cannot move the picker all the way to the end of its travel unless the picker fingers are horizontal. To make them horizontal, rotate the picker finger drive gear downward.

Figure 26 Picker Fingers Horizontal, Grasping Cartridge

Picker finger drive gear

60 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 87: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

3 Press down on the donut-shaped Carriage Release button located on the top of the picker near the center (see Figure 27). You can press down anywhere on this donut, but it is easiest to depress if you press down in the notch between the Spring Arm and the center post. You need to use a tool to do this. The tool can be a paper clip, a small flat-blade screwdriver, or other similar blunt instrument that will not break off (see Figure 28). Be careful not to drop the tool down into the library. Press down until the Carriage Release Button clicks and stays depressed (locked).

Figure 27 Carriage Release Button in Normal Operating Position (Flush With Top of Card)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 61

Page 88: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Figure 28 Depressing the Carriage Release Button

4 You can now move the picker carriage back and forth along the picker’s toothed gears (Z-axis). It should move smoothly with some resistance. If it does not, then stop. Do not attempt to move the picker carriage in any other direction.

5 When finished, you must remember to unlock the Carriage Release Button. Use the same tool you used to lock the Carriage Release Button. Place the end of the tool in the notch between the post and the spring arm (see Figure 28). Gently press the tool downward and also outward on the spring arm (toward the outside of the button) until you hear or feel a small “snap” as the latch releases. The Carriage Release Button should be flush with the top of the picker. If it stops part way up, you can wiggle the picker to cause the button to pop all the way up.

Center post

Notch

Spring arm

62 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 89: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Caution: If you forget to unlock the carriage release button, then when power is restored, the picker will fail to initialize.

6 Remove the tool.

7 The carriage release button should no longer be depressed. Make sure the picker carriage is locked by gently trying to move it along the z-axis. It should not move. If it moves, you did not properly lock the button.

Sliding the Picker Along the X-axis (Cartridge Stuck in Drive and Attached to Picker)

You might need to do this if the tape cartridge is stuck in the tape drive and still attached to the picker.

Use your hands to slide the picker toward the front or back of the library as necessary.

When pulling/pushing the picker, there are two locations you can use (see Figure 29).

• Push or pull on two of the picker corners where they sit on the metal side rods of the Y-tray. Push or pull on either the two front points or the two rear points at the same time.

• Push or pull on the metal base of the picker. Stay close to the center of the picker to avoid torquing the picker.

Caution: Do not pull on the belt. Do not push or pull on the picker card.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 63

Page 90: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Figure 29 Acceptable Locations for Sliding the Picker Along the X-axis

64 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 91: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Swiveling the Picker (Theta Axis)

During normal operations, the picker swivels 180 degrees to access slots on both sides of the library. In some error situations, you may need to swivel the picker manually, although it is unlikely.

To swivel the picker, lift up on the Theta Release Gear located behind the carriage (the gear has a spring visible on top of it). As you lift the Theta Release Gear, simultaneously hold down the top of the screw to stabilize the picker (otherwise you will torque the picker). Holding the Theta Release Gear up and the screw down, swivel the picker. The picker should swivel easily and without resistance. If it does not, then stop. See Figure 30 and Figure 31.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 65

Page 92: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Figure 30 Normal Position of Theta Gear

Stabilizing screw (press and hold down)

Theta Release Gear (lift up)

66 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 93: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Figure 31 Raising the Gear to Swivel the Picker

Raise this gear up

Stabilize by pressing down on this screw

Hold gear and screw in this position as you swivel the picker

Quantum Scalar i40 and Scalar i80 Maintenance Guide 67

Page 94: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Manually Unloading the Tape Drive

This procedure is different depending on which tape drive you have. This section covers:

• Manually Unloading the HP LTO-4 or LTO-5 Half-Height Tape Drive on page 68

• Manually Unloading the HP LTO-4 Full-Height Tape Drive on page 70

Manually Unloading the HP LTO-4 or LTO-5 Half-Height Tape Drive

1 Remove the drive sled from the library.

Caution: Do not remove the tape drive from the sled assembly!

2 Place the drive sled on its side with the bottom of the drive sled facing you and the front of the drive facing towards the left. The load motor drive shaft is at the top left and has a 6 mm molded hexagon for manual operation of the load mechanism (see Figure 32).

Caution: Do NOT place the drive upside down (so that it is lying on the top cover of the drive sled). The drive must be positioned on its side for this entire procedure until the tape cartridge is ejected.

3 Make sure the load motor drive shaft hex nut is in a fully clockwise position. Normally the hex is in the correct position; this step ensures that it is in the correct position. Using a 6 mm socket or nut-spinner, gently rotate the load motor hex clockwise as far as possible (there is no hard stop, but the gear will begin to spring back). This positions the grabber into the parking position. Note that the grabber may already be positioned in the parking position, so the load motor may not rotate.

Caution: The load motor should turn very easily. To avoid damage, do not use excessive force.

4 You can now unthread the tape. Read this entire step first before beginning.

68 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 95: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Note: This step is very difficult, because you must keep tension on the load motor hex nut while at the same time rotating the front reel motor, with the tape drive on its side. Using two people is ideal; otherwise, hold the hex nut fully clockwise with one hand while turning the front reel motor with the other.

a Keep the hex nut under very light tension while performing this step.

b Use the T-6 or T-8 Torx driver to rotate the front reel motor clockwise (see Figure 32). Use both hands on the Torx driver to keep the front reel rotating in a steady, continuous motion. A jerky, stop/start motion can cause tape loops to form and may prevent a complete unthread.

c You will hear clicking noises as the buckle comes off of the take-up reel and moves through the tape drive read/write head area. Rotate until you hear a final “click” and there is resistance to further motion. The front reel motor will stop rotating clockwise when the tape is completely unthreaded and the tape leader is successfully parked. If a significant length of tape is threaded, this step could take a long time (up to 2,500 rotations to fully rewind if the tape is completely threaded).

Note: You need to use a significant amount of torque to hear the “click” of the tape leader pin being parked in the cartridge.

Note: If you have a hard time parking the tape leader pin, you may need turn the load motor drive shaft fully clockwise (again) while trying to park the pin.

d Once you hear the final “click,” release the tension on the hex nut.

5 Turn the load motor drive shaft counter-clockwise using the 6 mm socket or nut-spinner until the cartridge is fully ejected. There will be some resistance as the cartridge comes free of the magnet. This resistance must be overcome to fully eject the cartridge.

6 Remove the cartridge by hand.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 69

Page 96: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

7 Inspect the tape cartridge per Figure 22 on page 51. If the tape cartridge passes the inspection, you can re-import into the library later.

Figure 32 Manual Unload - HP LTO-4 and LTO-5 Half-Height Tape Drive

Manually Unloading the HP LTO-4 Full-Height Tape Drive

1 Remove the drive sled from the library.

Caution: Do not remove the tape drive from the sled assembly!

2 Orient the drive on its side with the front of the drive facing toward the left as shown in Figure 33 below.

3 Turn the RD thumbwheel (shown in Figure 33 below) by hand towards back of drive as far as possible (there is no hard stop, but the wheel will begin to spring back). This positions the grabber into the parking position. Note that the grabber may already be positioned in the parking position.

Load motor drive shaft (hex nut)

Front reel motor shaft (T-6 or T-8 Torx)

70 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 97: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

4 Using a T-10 torx driver, rotate the front reel motor (shown in Figure 33 below) clockwise as far as possible.This unthreads the tape. The front reel motor will stop rotating clockwise when the tape is completely unthreaded and the tape leader is successfully parked. If a significant length of tape is threaded, this step could take a long time (up to 2,500 rotations to fully rewind if the tape is completely threaded).

5 Turn the RD thumbwheel (shown in Figure 33 below) by hand towards front of drive until cartridge is fully ejected. There will be some resistance as the cartridge comes free of the magnet. This will need to be overcome to get the cartridge in the fully ejected position.

6 Remove the cartridge by hand.

7 Inspect the tape cartridge per Figure 22 on page 51. If the tape cartridge passes the inspection, you can re-import into the library later.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 71

Page 98: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Figure 33 Manual Unload - HP LTO-4 Full-Height Tape Drive

RD Thumbwheel access

Front reel motor access; use T10 Torx driver

Front of tape drive

Back of tape drive

72 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 99: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

Reinstalling the Top Cover and Final Steps

1 Reinstall the top cover.

2 Replace the library in the rack or desktop kit.

WARNING: Two people are required to safely lift the library into and out of a rack.

3 Re-install magazines and tape drives in their proper slots.

4 Reconnect the power, Ethernet, and tape drive cords and cables.

5 Turn ON the library by pressing the power button on the front panel. Wait for the library to initialize.

6 Perform the Installation and Verification Test (IVT). From the operator panel, select Tools > IVT.

7 Inspect the recovered tape cartridge per Figure 22 on page 51. If the tape cartridge passes the inspection, you can re-import into the library. For instructions, see the Scalar i40 and Scalar i80 User’s Guide.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 73

Page 100: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 2: Lodged Tape Removal InstructionsRecovering a Cartridge by Removing Top Cover of Library

74 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 101: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3Installing, Removing, and

Replacing CRUs

This chapter describes how to install the library, and to add, remove, and replace hardware components that are considered customer replaceable units (CRUs).

WARNING: Two people are required to lift and install the library.

WARNING: Under no circumstances should a rack be moved while a library is installed.

This chapter covers:

• Taking ESD Precautions

• Connecting Library Cables

• Installing the Rack Mount Kit (Rail Kit)

• Installing the Library In a Rack

• Removing the Library From a Rack

• Installing the Library in a Desktop Kit

• Removing the Library from a Desktop Kit

• Removing and Replacing the Front Bezel

• Replacing the Chassis

• Removing and Installing a Filler Plate

Quantum Scalar i40 and Scalar i80 Maintenance Guide 75

Page 102: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsTaking ESD Precautions

• Removing and Replacing a Magazine

• Removing and Installing a Power Supply

• Removing and Replacing the System Control Board

• Removing and Replacing a Tape Drive

• Packaging the Library for Moving or Shipping

Taking ESD Precautions

Some components within the Scalar i40 and Scalar i80 libraries contain static-sensitive parts. To avoid damaging these parts while performing installation procedures, always observe the following precautions:

• Use an antistatic wrist strap. If you do not have one, touch the outside of the library on the sheet metal before touching any components to discharge static from your body.

• Keep static-sensitive parts in their original shipping containers until ready for installation. Look for the ESD sticker to identify static sensitive parts.

• Avoid touching connectors and other components.

Note: Dry climates and cold-weather heating environments have lower relative humidity and are more likely to produce static electricity.

76 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 103: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsConnecting Library Cables

Connecting Library Cables

Connect the cords and cables as follows (see Figure 34 on page 78). It is recommended that you leave some slack in the cables to allow you to perform certain replacement procedures in the future.

1 Connect the tape drive cables from the tape drives to the host.

Caution: Use care when handling the fibre optic cables. Do not crimp or bend the cables. Do not exceed the bend radius specified by the manufacturer.

2 Connect an Ethernet cable (not supplied with your library) into the LEFT port on the system control board (SCB). The right SCB port is for service use only; do not use. Connect the other end of the Ethernet cable into a live Ethernet jack connected to your network.

3 Connect the power supply cord into the power supply connector. Plug the other end of the cord into a grounded AC outlet.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 77

Page 104: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsConnecting Library Cables

Figure 34 Connection Locations

Ethernet cable in LEFT SCB port

Fibre Channel cables in LEFT port of full-height tape drives

Filler plate

Power supply cord

Filler plate

Service port

Full-height tape drives

Half-height tape drives

Filler plate

Power supply cord

Tape drive cables Ethernet cable in LEFT SCB port

Service port

78 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 105: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

Installing the Rack Mount Kit (Rail Kit)

The instructions for installing the rails are the same for both the Scalar i40 and the Scalar i80.

WARNING: If the rack is empty at the time of installation, do NOT install the library too high in the rack. The weight of the library may cause the rack to become “top heavy” and unstable if installed in the top of an empty rack.

WARNING: Do not stack objects on top of the library such as cables or other computer equipment. The additional weight could exceed the amount supported by the rack shelves.

Caution: Make sure the rack mounting rails are level, both left to right and front to back. If the library is not level in the rack, it will not work properly.

Supported Rack Types The Scalar i40 and Scalar i80 libraries are designed to fit in most standard 19-inch equipment cabinets, including:

• Dell, 08P157 (US-08P157910-3AU-0900),square, 2.48 - 2.72 mm thick

• SUN, 38U, NGR900R, M6

• Emcor, 10 Series, round hole

• IBM, Machine Type 9306, Model 900, square, 28.25-inch deep, 2.0-2.25 mm thick

• HP, 10K, PN 245169-001, Asm 10642U GR Metallic, square, 2.0-2.2 mm thick

• EMC CX500

• Rittal Cable Tester Rack Frame, square

Rack depth of 34 in. (86.3 cm) minimum is recommended; however, rack depths of 24 to 36 in. (60.9 to 91.4 cm) are supported.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 79

Page 106: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

Space Requirements See the user’s guide for physical specifications and air clearance requirements.

Tools Required • Phillips screwdriver

• Magazine lock override tool — an opened paperclip, small screwdriver, or other object (3.5 mm or less in diameter that will not break off)

Rack Mount Kit Contents

The following items are included in the rack mount kit:

Qty Figure Description

2 Shelf

2 Shelf Extender

16 Phillips head screw, countersunk (M5 x 10) – for shelf assembly

8 T- nut (M5) – for shelf assembly

80 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 107: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

Installing the Rack Mount Shelves

Before installing the rack mount shelves, you must collect the following information:

• Type of rack mount rails (square hole, through hole, or threaded hole)

• Depth of rack

1 Assemble the rack mount shelves included in the accessory kit (left and right):

a The holes used to attach the two halves of the rack mount shelves differ depending on the depth of the rack (see Figure 35 on page 82). It is recommended that you use the ones that are exposed and have the widest spacing.

8 total Rail adapter — 4 each of two types are included. You need 4 for installation; choose the type appropriate for your rack (for more information, see Figure 37 on page 84)

8 Phillips head screw, countersunk (M4 x 12) – for mounting shelves to rack

8 Washer, countersunk – for mounting shelves to rack

4 Clip nut (M5 x 0.8) – for securing library in rack

4 Cage nut (M5) – to secure library to rack. Used in racks with square or round non-threaded holes.

Qty Figure Description

Quantum Scalar i40 and Scalar i80 Maintenance Guide 81

Page 108: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

Fron

t of rack

Figure 35 Rack Mount Shelf Depth Requirements

b Loosely attach the rack mount shelves to the extenders with 4 M5 x 10 screws and T-nuts (see Figure 36).

Use these holes for rack depths of 27 in (68.5 cm) to 36 in (91.4 cm)

Use these holes for rack depths of 24 in (60.9 cm) to 28 in (71.1 cm)

Use these holes for rack depths of 27 in (68.5 cm) to 36 in (91.4 cm)

Use these holes for rack depths of 24 in (60.9 cm) to 28 in (71.1 cm)

Fro

nt

of

rack

Rear o

f rack

Rea

r o

f ra

ck

82 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 109: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

Figure 36 Assembling the Left and Right Rack Mount Shelves

M5 x 10 screws

M5 x 10 screws

T-nuts

T-nuts

Left-side ra

ck mount sh

elf

Right-side rack mount shelf

T-nuts must be oriented as shown to properly fit in the shelf adjustment slot

T-nuts must be oriented as shown to properly fit in the shelf adjustment slot

The metal fold must be toward the outside of the shelf as shown

The metal fold must be toward the outside of the shelf as shown

Bac

k o

f ra

ck

Fro

nt

of

rack

Back o

f rackExte

nder

Extender

Quantum Scalar i40 and Scalar i80 Maintenance Guide 83

Page 110: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

c Determine the type of rail adapter required for your rack. Each rail adapter is marked with the specific hole type supported (see Figure 37).

Figure 37 Rail Adapter Types

Use the rail adapters with blocks on rails with square hole patterns

Use the rail adapters with circle pegs (opposite blocks) on rails with non-threaded circle hole patterns

Use the rail adapters with small circle pegs on rails with threaded circle hole patterns (M6 on one side and M5 on the other side)

84 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 111: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

d Attach the appropriate rail adapter to the front and back of the rack mount shelves (right and left) with 2 M5 x 10 screws per adapter (see Figure 38).

Figure 38 Assembling the Left-Hand Rack Mount Shelf

M5 x 10 screws

Rail adapter

Left shelf

Arrow must point up

M5 x 10 screws

M5 x 10 screws

Rail adapters

Right shelf

M5 x 10 screws

Rail adapter

Arrow must point up

Quantum Scalar i40 and Scalar i80 Maintenance Guide 85

Page 112: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

2 Install the left and right rack mount shelves into the rack (the rack mount shelves adjust 24 to 36 in.) and secure with the following parts in four locations (see Figure 39 on page 87):

• 2 washers

• 2 M4 x 12 screws

Note: The rack mount shelves must be installed on the inside rack rails.

86 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 113: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

Figure 39 Installing the Rack Mount Shelves

Left shelf

Right shelf

Washers

M4 x 12 screws

Quantum Scalar i40 and Scalar i80 Maintenance Guide 87

Page 114: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

3 Once the rack mount shelves are secured to the rack, tighten the screws securing the adjustable shelves (right and left) together (see Figure 40).

Figure 40 Tightening the Rack Mount Shelves

Tighten screws to secure both rack mounting rails

88 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 115: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Rack Mount Kit (Rail Kit)

4 If the rack does not have threaded holes, install a clip nut or a cage nut in the back side of the rail, in the first empty hole below the rail adapter. This is what you will screw the library thumbscrews into to secure the library in the rack. See table below for type of nut, and Figure 41 on page 90 for installation location.

Type of Rail/Type of Nut Description

Square rack holes are the most common type of rack holes. They can accept either cage nuts which mount from the back of the rail or clip nuts which clip on from the side of the rack rail.

Round, unthreaded holes require clip nuts to accept mounting hardware.

Threaded holes require neither cage or clip nuts to accept mounting hardware.

Cage nut

Clip nut

Clip nut

Quantum Scalar i40 and Scalar i80 Maintenance Guide 89

Page 116: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library In a Rack

Figure 41 Location for Installing the Clip Nut or Cage Nut

Installing the Library In a Rack

Caution: Make sure the rack mounting rails are level, both left to right and front to back. If the library is not level in the rack, it will not work properly.

WARNING: At least two people are required to lift and install the library.

1 If tape drives are installed in the library, you may wish to remove them to reduce weight. To remove tape drives, unscrew the captive thumbscrews securing them to the back of the library and slide them out of the library. Set them down gently on a stable surface.

Clip nut or cage nut installed in the first empty hole below rail adapter

Rail adapter

90 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 117: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library In a Rack

2 Lift the library, place it on the rack shelves, and slide it into the rack as far as it will go.

3 Open one of the magazines slightly to access the captive thumbscrew that is attached to the library chassis. You will use this thumbscrew to secure the library to the rack. To open the magazine, insert the magazine lock override tool into the access hole in the bottom of the magazine bezel (see Figure 42 on page 91). Use the tool to depress the release latch while gently pulling outward on the magazine bezel handle. Right-side magazines will only slide out as far as the I/E station (one column of slots). To release the right-side magazines fully:

• On the Scalar i40 and the bottom right magazine of the Scalar i80, reach under the open magazine and insert the tool directly into the access hole in the library chassis to depress the release latch, while pulling out on the magazine bezel handle.

• On the top right magazine of the Scalar i80, reach under the open magazine and press the release latch directly with your finger, while pulling out on the magazine bezel handle.

Figure 42 Magazine Release Latch Access Holes

4 Screw the captive thumbscrew finger-tight into the rack (and through the clip nut or cage nut, if installed). See Figure 43 on page 92.

5 Repeat Step 3 and Step 4 for the remaining thumbscrews.

6 Close all the magazines by pushing them in until they click shut.

Magazine release latch access holes

Quantum Scalar i40 and Scalar i80 Maintenance Guide 91

Page 118: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving the Library From a Rack

Figure 43 Securing the Scalar i40 and Scalar i80 in the Rack

Removing the Library From a Rack

WARNING: At least two people are required to lift the library and remove it from a rack.

1 Shut down the library by selecting Actions > Shutdown from the operator panel.

2 Turn OFF the library by pressing the power button on the front panel.

3 Disconnect the power supply cord, the Ethernet cable, and all tape drive cables from the back of the library. If you have multiple tape drives, label the cables so you can reconnect them to the correct tape drives later.

92 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 119: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

4 Remove all the tape drives from the library (for details, see Removing and Replacing a Tape Drive on page 137).

5 Remove all the magazines from the library (for details, see Removing and Replacing a Magazine on page 121).

6 Unscrew the captive thumbscrews in the “rack ears” that secure the library to the rack (see Figure 43 on page 92).

7 Slide the library out of the rack. Keep the library level as you slide it out of the rack.

8 Place the library on a flat, stable surface.

Installing the Library in a Desktop Kit

The instructions for installing the Scalar i40 and the Scalar i80 in a desktop are the same. The only difference is that the Scalar i40 has two side panels, and the Scalar i80 has four.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 93

Page 120: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

Figure 44 Desktop Kit, Scalar i40 and Scalar i80

Scalar i40

Scalar i80

94 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 121: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

Kit Contents

Tools Required • Phillips screwdriver

• Magazine lock override tool — an opened paperclip, small screwdriver, or other object (3.5 mm or less in diameter that will not break off)

Item Quantity

Top cover 1

Side panel 2 for the Scalar i40; 4 for the Scalar i80

Top cover screws 2

Rubber feet 8

Quantum Scalar i40 and Scalar i80 Maintenance Guide 95

Page 122: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

Space Requirements See the following user’s guide for physical specifications and air clearance requirements.

Procedure WARNING: Two people are required to safely lift the library.

1 If your library is currently installed in a rack, remove the magazines and tape drives, and then remove the library from the rack. See Removing the Library From a Rack on page 92.

2 Set the library on the desk or table in your chosen location.

3 Remove all the magazines from the library (if you have not already done so), as follows:

a Insert the magazine lock override tool into the access hole in the bottom of the magazine bezel (see Figure 45).

b Use the tool to depress the release latch while gently pulling outward on the magazine bezel handle. If the magazine is on the right side, it will only slide out as far as the I/E station. To release the magazine fully:

• On the Scalar i40 and the bottom right magazine of the Scalar i80, reach under the open magazine and insert the tool directly into the access hole in the library chassis to depress the release latch, while pulling out on the magazine bezel handle.

• On the top right magazine of the Scalar i80, reach under the open magazine and press the release latch directly with your finger, while pulling out on the magazine bezel handle.

Figure 45 Magazine Release Latch Access Holes

Magazine release latch access holes

96 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 123: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

4 Look through the magazine slot openings to be sure the Y-tray is resting on the floor of the library. If not, reach inside and gently press down on one of the Y-tray’s side metal rods until the Y-tray starts moving. It should drift down to rest on the floor of the library.

5 Turn the library carefully on its side (either the left or right side). Make sure the front end of the library (the “rack ear”) overhangs the edge of the table so that the library lies flat.

6 Install the eight rubber feet on the bottom of the library, as follows:

a There are eight holes in the bottom of the library into which you will press the rubber feet. Four holes are located along the right edge and four along the left edge. Figure 46 shows the locations of these holes.

b Use your fingers to press the feet into the holes. Twisting the feet as you push them may make it easier to get them in. See Figure 46 on page 98.

c Carefully turn the library back to an upright position so that it is resting on its rubber feet.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 97

Page 124: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

Figure 46 Location of Rubber Feet on Bottom of Library

7 Install the side panels one at a time (in any order) as follows (see Figure 47 on page 100):

a Orient the side panel correctly. They are all the same but can only be installed one way. Line up the eight posts on the inside of the side panel with the holes in the side wall of the library. Line up the screw hole in the bottom front of the side panel with the captive thumbscrew behind the magazine on the library chassis.

b Press the side panel against the wall so that the posts go into the holes.

98 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 125: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

c Slide the side panel toward the front of the library about half an inch until it stops and the posts are engaged in the holes. The side panel should be flush with the side of the library chassis.

d Tighten the thumbscrew at the front of the library to secure the side panel to the library.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 99

Page 126: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsInstalling the Library in a Desktop Kit

Figure 47 Installing the side panels

Hole for captive thumbscrew

Captive thumbscrew

Holes for side panel posts

Magazine release access holes

Inset showing captive thumbscrew behind open magazine

100 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 127: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving the Library from a Desktop Kit

8 Install the top cover as follows (see Figure 48):

a Slide the top cover onto the library, from back to front. The back of the top cover has two screw holes and overhangs the back of the library.

b Install the two top cover screws through the top cover and into the screw holes in the top of the side panels.

Figure 48 Installing the Top Cover

9 Re-install the magazines and push them in until they close.

10 Re-install tape drives if you removed them previously.

11 Connect the tape drive cables, Ethernet cable, and power cord (see Connecting Library Cables on page 77).

Removing the Library from a Desktop Kit

To remove the library from a desktop kit, reverse the steps in Installing the Library in a Desktop Kit on page 93.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 101

Page 128: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the Front Bezel

Removing and Replacing the Front Bezel

The procedure is similar for the Scalar® i40 and the Scalar i80. Pictures of the Scalar i40 also apply to the Scalar i80.

You may perform this procedure with library power ON. If you do, be careful not to accidentally press the power button and turn the library off when installing the bezel.

Read these instructions completely before beginning.

Required Tools • Phillips #1 screwdriver

Bezel Replacement Kit Contents

• 1 Bezel

• 4 screws

Bezel Replacement Procedure

1 Stop all library operations.

2 Open all the magazines in the library a few inches or remove them completely from the library.

Note: There is less chance of scratching or damaging the new bezel when you install it if you completely remove the magazines. On the Scalar i80, it is easier to perform this procedure with at least the bottom two magazines completely removed. You need room to maneuver your fingers on the sides of the bezel. If you remove all the magazines from a Scalar i80, label them so that you can reinstall them in the same locations later.

a On the operator panel, select Actions > Magazine.

b Select a magazine and press Release.

c When prompted, pull open the magazine a few inches.

d Repeat for all magazines in the library.

102 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 129: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the Front Bezel

3 Prepare to gain access to the bezel screws (see Figure 49 on page 104 and Figure 50 on page 105 for locations). The method depends upon how your library is installed. Follow the instructions in the table below that correspond to your library installation.

4 Slide the library one-to-two inches forward out of the rack or over the edge of the table or desk in order to access the two bottom bezel screws.

WARNING: Only slide the library out far enough out to access the two screws on the bottom of the library. The library is not secured in the rack or on the desk. Pulling it out too far could cause the library to slide out of the rack or off the desk.

Caution: Ensure there is enough slack in the power cords and cables connected in the rear of the library so that you do not dislodge them when you slide the library forward.

Caution: Do not tip the library or tilt it on its side.

5 Make sure all the magazines are pulled out a few inches (or removed) to allow you to remove and install the bezel without damaging it.

If your library is... Follow these steps...

Installed in a rack high enough to access to the bottom bezel screws

Unscrew all the thumbscrews that secure the library to the rack (the Scalar i40 has two thumbscrews; the Scalar i80 has four). See Figure 50 on page 105.

Installed in a desktop kit Release the desktop cover by removing two screws at rear of the desktop cover, then slide the desktop cover toward the back of the library two or three inches.

Installed very low in a rack so that you cannot access the bottom bezel screws unless you remove the library from the rack

Remove the library from the rack (see Removing the Library From a Rack on page 92).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 103

Page 130: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the Front Bezel

6 Remove and set aside the two screws securing the bezel to the bottom of the chassis (see Figure 49 on page 104).

7 Remove and set aside the two screws securing the bezel to the top of the chassis (see Figure 50 on page 105).

Figure 49 Bezel Screw Locations on Bottom of Library

Bottom bezel

screws

104 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 131: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the Front Bezel

Figure 50 Bezel Screws

8 Remove the bezel as follows:

• Scalar i40: Grasp the bezel gently at the top and bottom and pull the bezel straight out and off of the library. Do not tip or twist the bezel as you pull it off.

• Scalar i80: Use your fingers to grasp the bezel near the center on both sides and pull outward to disengage the bezel (see Figure 51 for location). There are plastic tabs on the inside of the bezel that help secure the bezel to the library and pulling outward from this location helps disengage them. You may need to move the bezel slightly back and forth to remove it.

Thumbscrew securing library to rack

Quantum Scalar i40 and Scalar i80 Maintenance Guide 105

Page 132: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the Front Bezel

Figure 51 Scalar i80 Pull/Push Locations

9 Install the new bezel straight onto the library. Do not tip or twist the bezel. If magazines are still in the library, be careful not to scratch or damage the bezel as you install it. Slide the top and bottom edges of the bezel to the inside of the top and bottom layers of the chassis sheet metal. On the Scalar i80, press in near the center on both sides of the bezel until you hear it “snap” into place (see Figure 51 for locations).

Caution: Make sure the power button and all four operator panel control buttons appear through the holes in the bezel and are not trapped beneath the bezel.

Caution: Be careful not to accidentally hit the power button and turn the library off while you are installing the bezel.

10 Install the two top screws, then the two bottom screws.

11 Reinstall the library in the rack or desktop kit.

12 Close all the magazines.

13 If you turned the library off to perform this procedure, turn it ON now by pressing the power button on the front panel. Wait until the library initializes before resuming library operations.

Pull in this area when removing

bezel. Push in this area when

installing bezel.

Pull in this area when removing bezel. Push in this area when installing bezel.

106 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 133: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

14 If you removed the library from the rack to perform this procedure, run the Installation and Verification Test (IVT) to ensure the Y-tray, tape drives, and magazines are all functioning properly. From the operator panel, select Tools > IVT and follow the instructions on the screen. The IVT takes about 30 minutes. See Running the Installation and Verification Test (IVT) on page 211 for more information about the IVT. If any problems are detected, the library issues a diagnostic ticket.

Replacing the Chassis

DISCLAIMER: Tests have been conducted on the finished product and have passed Safety Regulatory requirements at time of test.

WARNING: For field/customer replaceable sub-assemblies, all instructions pertaining to further integration and operation verification such as those in this document must be fully complied with. Do not attempt to operate the product before the product is fully assembled and self diagnostics show that the product passes, otherwise serious physical injury may occur to the user. The manufacturer(s) will not be held liable/responsible if such precautions are not adhered to.

WARNING: Two people are required to safely lift the library into and out of its packaging, a rack, or a desktop kit.

When you replace a library chassis, you will remove all the components from your existing library and install them in the new library.

Required Tools • Phillips #1 screwdriver

• Magazine lock override tool — an opened paperclip, small screwdriver, or other object (3.5 mm or less in diameter that will not break off)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 107

Page 134: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Procedure When you replace a library chassis, you will remove all the components from your existing library and install them in the new library.

1 Unpack the new library chassis and place it on a flat, level surface.

2 Verify that the new chassis is the same type (Scalar® i40 or Scalar i80) as the unit you are replacing.

3 If you had license keys installed on your library, you will need to install new ones on the replacement library. Contact Quantum Support to request new license keys.

4 If the library you are replacing is still turned on and operational, shut down the library by selecting Actions > Shutdown from the operator panel.

5 Turn OFF the library by pressing the power button on the front panel.

6 Disconnect the power supply cord, the Ethernet cable, and all tape drive cables from the back of the library. If you have multiple tape drives, label the cables so you can reconnect them to the correct tape drives later.

7 Remove all of the following components from the library (see Figure 52 on page 110).

Component to Remove Instructions

Power SuppliesCaution: Make sure the power supply is unplugged and disconnected

from live power before you remove it.

1 Disconnect the power cord from the back of the power supply. 2 Unscrew the captive thumbscrews. 3 Pull outward on the power supply handle to remove it from the library.

System Control Board (SCB)

1 Loosen the two captive thumbscrews on the SCB. 2 Grip the thumbscrews and pull outward to slide the SCB out of the library.3 Place the SCB on an anti-static surface or in an anti-static bag.

108 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 135: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Tape Drives 1 Label each tape drive with its location in the library slots. It is recommended that you reinstall the tape drives in the same location in the new chassis.

2 Unscrew the captive thumbscrews securing the tape drive sled to the back of the library. Half-height tape drives have two thumbscrews. Full-height tape drives have four thumbscrews.

3 Using the handle, pull the drive sled out of the library. It should slide out smoothly and easily.

Filler Plates Remove all filler plates (tape drive and power supply).1 Unscrew the two captive thumbscrews.2 Pull the filler plate out.

Magazines 1 If your library is a Scalar i80, label the magazines so you can reinstall them in the same slots.

2 Insert the magazine lock override tool into the access hole in the bottom of the magazine bezel.

3 Use the tool to depress the release latch while gently pulling outward on the magazine bezel handle. If the magazine is on the right side, it will only slide out as far as the I/E station. To release the magazine fully: • On the Scalar i40 and the bottom right magazine of the Scalar i80, reach

under the open magazine and insert the tool directly into the access hole in the library chassis to depress the release latch, while pulling out on the magazine bezel handle.

• On the top right magazine of the Scalar i80, reach under the open magazine and press the release latch directly with your finger, while pulling out on the magazine bezel handle.

Component to Remove Instructions

Quantum Scalar i40 and Scalar i80 Maintenance Guide 109

Page 136: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Figure 52 Components to Remove

8 If the library is in a desktop kit or rack, remove it.

• To remove the library from a rack, unscrew the captive thumbscrews on the front of the library that secure the library to the rack, then slide the library out of the rack. Place the library on a flat, stable surface.

WARNING: Two people are required to safely lift the library out of a rack.

Magazine release access holes

Remove Remove

110 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 137: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

• To remove the library from a desktop kit, remove the two top cover screws at the rear of the top cover. Loosen the captive thumbscrews on the library chassis that are attached to the side panels of the desktop kit. Slide the side panels one-half inch toward the rear of the library to disengage the side-panel posts from the library wall, then pull the side panels off.

Do NOT remove the eight rubber “feet” installed on the bottom of the library (you will remove them later, in Step c, Sub-Step c on page 113, once the library is set on its side).

9 Remove the Y-tray restraint from the replacement chassis.The Y-tray restraint consists of four (4) thumbscrews, a plastic sheet, a small metal clip, and underneath the plastic sheet, an orange restraint tab (see Figure 53).

a Unscrew and remove the four thumbscrews from the top cover. Save the thumbscrews for use in restraining the Y-tray in the chassis you are returning.

b Remove the plastic sheet and metal clip and discard. You will not need to use them again.

c IMPORTANT: Remove the orange shipping restraint tab and discard. You will not need to use it again.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 111

Page 138: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Figure 53 Removing the Y-tray Restraints

Note: The Y-tray may stay at the top of the library, or it may move downward toward the floor of the library. If it moves downward, you will hear the gears turning as it moves. This is normal.

10 Restrain the Y-tray in the chassis being returned as follows (see Figure 54 on page 113):

a Look through the magazine slot openings to be sure the Y-tray is resting on the floor of the library. If not, reach inside and gently press down on one of the Y-tray’s side metal rods until the Y-tray starts moving. It should drift down to rest on the floor of the library.

b Turn the library carefully on its side (either the left or right side). Make sure the front end of the library (the “rack ear”) overhangs the edge of the table so that the library lies flat.

Caution: Do not turn the library upside down. Do not turn the library more than 90 degrees from upright.

112 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 139: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

c If your library was installed in a desktop kit, remove the eight rubber “feet” installed on the bottom of the library. You can remove them by twisting them as you pull them out. Save them to use on the replacement chassis.

d Take the four thumbscrews you just removed from the replacement chassis and install them into the floor of the chassis you are returning in the locations shown in Figure 65. They will screw through the Y-tray and secure it in place on the floor of the chassis.

e Do NOT turn the library back to an upright position at this point. Leave it on its side until you place it in the box.

Caution: If you place the library upright with the Y-tray restraint thumbscrews installed, you could damage the chassis or the Y-tray.

Figure 54 Restraining the Y-tray

Four Y-tray restraint thumbscrews

Rack “ear” overhangs edge of desk or table

Quantum Scalar i40 and Scalar i80 Maintenance Guide 113

Page 140: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

11 If desired, you may cover the holes in the replacement library top cover with stickers, which are provided in the accessory kit for this purpose. This step is optional and is intended to prevent small objects from accidentally falling into the library through the holes.

12 Install the new chassis in a rack or desktop kit. For instructions, see Installing the Rack Mount Kit (Rail Kit) on page 79 or Installing the Library in a Desktop Kit on page 93.

WARNING: Two people are required to safely lift the library.

13 Install the components you removed from the old chassis into the new chassis.

Component to Install Instructions

System Control Board (SCB)

Install the SCB before you install the power supply.1 Position the SCB for installation: The board components face up. The flat

part of the board faces down. The thumbscrews are on the upper side of the SCB back plate.

2 Install the new SCB by pushing the SCB into the slot until it stops. It should slide smoothly and easily. When it reaches the end of its travel, press firmly on the back panel of the SCB to “snap” it into place.

3 Tighten the two thumbscrews finger tight.4 Connect the Ethernet cable to the LEFT Ethernet port (as viewed from the

back of the library; see Figure 55 on page 117).

114 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 141: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Power Supplies If your library is a Scalar i80 and you have only one power supply, install it in the top slot. If you have two power supplies, install them both.

Caution: Make sure the power supply is unplugged and disconnected from live power before you install it.

1 Push the power supply straight into the slot. You may need to press firmly on the power supply sheet metal at the very end to plug in the power supply to the connector on the library. You will feel it snap into place. The power supply only goes in one way, and should slide in easily. If you cannot slide it in, you may be trying to install it upside down.

2 Tighten the two thumbscrews finger tight.3 Connect the power cord to the power supply.4 Plug the power cord into a grounded AC outlet.

Component to Install Instructions

Quantum Scalar i40 and Scalar i80 Maintenance Guide 115

Page 142: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Tape Drives 1 Insert the tape drives into the same drive slots they were in the old chassis. The “shelf” on the bottom of the drive sled fits into the notch in the library chassis and slides on the plastic guide rails. The tape drive must be level to slide in smoothly. At the very end of the slide, you will feel a slight “click” as the tape drive sled connector connects into its mating connector in the library chassis.

2 Tighten the tape drive’s captive thumbscrews finger tight to secure the tape drive to the library chassis.

3 Connect all tape drive cables as they were in the old unit. Make sure they are connected to the host or switch as they were before. For full-height Fibre Channel tape drives, the cable must go in the LEFT connector (as viewed from the back of the library; see Figure 55 on page 117).

Filler Plates Make sure every empty power supply slot and tape drive slot is covered with a filler plate.1 Slide the filler plate into the slot.2 Tighten the thumbscrews.

Magazine Slide each magazine into its slot and push it in all the way until it stops.

Component to Install Instructions

116 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 143: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

Figure 55 Reinstalled Components

Half-height tape drives

Tape drive cables Ethernet cable in LEFT SCB port

Service port

Filler plate

Power supply cord

Filler plate

Power supply cord

Filler plate

Full-height tape drives

Ethernet cable in LEFT SCB port

Fibre Channel cables in LEFT port of full-height tape drives

Service port

Quantum Scalar i40 and Scalar i80 Maintenance Guide 117

Page 144: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsReplacing the Chassis

14 Turn ON the library by pressing the power button on the front panel.

15 Wait for the library to initialize. This can take up to 5 to 17 minutes, depending on library size.

16 You will notice the library has a new diagnostic ticket (DT042) stating the library’s vital product data (VPD) has changed.

17 Since the VPD change is caused by the intentional library chassis replacement, follow the Diagnostic Ticket resolution steps to reconfigure the host application accordingly.

18 If you had license keys installed on the old library, install the new license keys. From the operator panel, select Setup > License Installation; or from the Web client, select Setup > License. For further directions, see the user’s guide.

19 Run the Installation and Verification Test (IVT) to ensure the Y-tray, tape drives, and magazines are all functioning properly. From the operator panel, select Tools > IVT and follow the instructions on the screen. The IVT takes about 30 minutes. See Running the Installation and Verification Test (IVT) on page 211 for more information about the IVT. If any problems are detected, the library issues a diagnostic ticket.

20 Save the library configuration (from the Web client, select Tools > Save/Restore Configuration and save the configuration to a known location).

21 Wrap the removed chassis in the antistatic wrapping that contained the replacement chassis. Package the removed chassis using the packaging that contained the replacement chassis. Use the enclosed RMA information to send the chassis back to Quantum.

22 If your library is running SKM, you must you run a special script on the SKM server after you replace the chassis. The script will correct the library serial number associations in the key server database and allow you to export used SKM encryption keys via the Web client correctly. For instructions, refer to the chapter titled “Updating the SKM Keystore After Replacing a Library Control Module” in the Scalar Key Manager 2.0 User’s Guide.

118 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 145: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Installing a Filler Plate

Removing and Installing a Filler Plate

A filler plate is required to cover every empty tape drive and power supply slot on the rear of the library, in order to maintain proper library cooling. If you remove a tape drive or power supply from the library, you must cover the opening with a filler plate.

There are two types of filler plates:

• Tape drive

• Power supply

Removing and Installing a Tape Drive Filler Plate

The filler plate is half-height in size. If you remove a full-height tape drive, you must install two filler plates to cover the opening.

Removing a tape drive filler plate

1 Unscrew the two captive thumbscrews and pull the filler plate out.

2 Save the filler plate in case you need to use it again.

Installing a tape drive filler plate

• The tape drive filler plate has no “top” or “bottom” orientation – it can go in either way (see Figure 56 on page 120).

• Slide the filler plate into the slot and tighten the thumbscrews.

Removing and Installing a Power Supply Filler Plate

The power supply filler plate is used only on the Scalar® i80 when only one power supply is present.

Removing a power supply filler plate

1 Unscrew the two captive thumbscrews.

2 Pull out on the thumbscrews so the filler plate is at a slight angle and the bottom of the filler plate is still attached in the slot.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 119

Page 146: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Installing a Filler Plate

3 Lift the filler plate up to disengage the catch at the bottom and pull the filler plate out of the slot.

Installing a power supply filler plate:

On the Scalar i80, if you are using only one power supply, you should install the power supply in the upper slot, and cover the lower slot with a filler plate (see Figure 56 on page 120).

1 Hold the filler plate with the thumbscrews at the top.

2 Insert the bottom edge of the filler plate into the slot, engaging the bottom edge of the filler plate into the bottom of the slot.

3 Pivot the filler plate up to fit securely in the hole.

4 Tighten the thumbscrews.

Figure 56 Filler Plates Installed

Power supply filler plate

Tape drive filler plate

Single power supply installed in top slot

120 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 147: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Magazine

Removing and Replacing a Magazine

The procedure for replacing magazines is the same on the Scalar® i40 and the Scalar i80.

Note: The library can operate with one or more magazines uninstalled. However, it will operate at reduced speed.

Required Tools • Phillips #1 screwdriver

Magazine Replacement Kit Contents

• (1) magazine

• (1) left-side magazine bezel

• (1) right-side magazine bezel

• (4) M3 x 6 Phillips head screws

• (4) washers

Creating a Backup Map of Cartridge Locations

When you transfer tape cartridges from the removed magazine into the replacement magazine, each cartridge needs to go in the same slot position it was in previously. One way to do this is to transfer the cartridges one by one from one magazine to the other. However, if the cartridges get mixed up or dropped, you need a backup method to know where to place your cartridges. The library configuration report provides a convenient backup “map.”

1 On the Web client, select Reports > Library Configuration.

2 Click the Show Barcodes button.

The screen displays a map of the library showing the location of each cartridge, by barcode.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 121

Page 148: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Magazine

3 Click the “print” icon in the upper right corner to print the report.

Alternatively, take a screen capture of the report and save or print it, or copy the map by hand.

Removing the Magazine from the Library

You can perform this procedure with library power on.

1 From the operator panel, select Actions > Magazine.

2 Use the Up and Down buttons to select the magazine you want to remove and press Release.

3 Wait for the operator panel to display the message: “Magazine is now unlocked. Waiting for the magazine to be moved to the expected position.”

4 Pull the magazine bezel out and remove the magazine from the library. If you do not remove the magazine within 30 seconds, the magazine locks again.

Note: If the library is turned off, you can release the magazine manually by inserting an opened paperclip, small screwdriver, or other object (3.5 mm or less in diameter that will not break off) into the access hole in the bottom of the magazine bezel (see Figure 57). Use the tool to depress the release latch while gently pulling outward on the magazine bezel handle. Right-side magazines will only slide out as far as the I/E station. To release right-side magazines fully: – On the Scalar i40 and the bottom right magazine of the Scalar i80, reach under the open magazine and insert the tool directly into the access hole in the library chassis to depress the release latch, while pulling out on the magazine bezel handle. – On the top right magazine of the Scalar i80, reach under the open magazine and press the release latch directly with your finger, while pulling out on the magazine bezel handle.

122 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 149: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Magazine

Figure 57 Magazine Release Latch Access Holes

Installing the Magazine The replacement magazine can be used on either the left or right side of the library, depending on how it is oriented. Once it is oriented correctly, the left or right bezel can be attached.

You can perform this procedure with the library powered on.

1 Place the removed magazine in the orientation it would be if it were installed in the library.

2 Place the replacement magazine next to the removed magazine in the same orientation. Make sure they look the same from all angles.

• The storage slots face inward.

• On the outer wall of the magazine, the silver rollers sit below the springs (see Figure 58).

Magazine release latch access holes

Quantum Scalar i40 and Scalar i80 Maintenance Guide 123

Page 150: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Magazine

Figure 58 Proper Orientation (Right-Side Magazine)

3 Choose the correct bezel (left or right) from the magazine replacement kit.

Note: If you try to install the wrong bezel, it will not fit and you will not be able to install it.

4 Push up on the top bezel tabs and fit them over the posts on the top of the magazine. Turn the magazine over and repeat on the bottom (see Figure 59 on page 125).

5 Install the two washers and two M3 screws securing the top of the bezel to the magazine. Install them in the outer hole in each tab (see Figure 59 on page 125).

6 Turn the magazine over and install the two washers and two M3 screws securing the bottom of the bezel to the magazine. Install them in the outer hole in each tab (see Figure 59).

Springs

Silver rollers

124 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 151: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Magazine

Figure 59 Removing/Installing the Magazine Bezel

7 Remove the tape cartridges from the removed magazine and carefully install them in the exact same slots in the replacement magazine. Use the map you created if necessary.

8 Slide the magazine into the magazine slot all the way until it stops.

The library performs an inventory on the replaced magazine.

9 Wait for the library to finish its inventory.

10 Run the magazine diagnostics test on the replaced magazine to be sure it is functioning correctly.

a Place a scratch tape in the top I/E station slot.

b If manual cartridge assignment is enabled, assign the scratch tape to the System partition.

Bezel Tab

Quantum Scalar i40 and Scalar i80 Maintenance Guide 125

Page 152: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Installing a Power Supply

c From the operator panel, select Tools > Diagnostics.

d Continue through the next few screens to run the magazine test on the replaced magazine.

If a problem is found during testing, you receive a diagnostic ticket. See Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests on page 213 more information.

Removing and Installing a Power Supply

The Scalar® i40 contains one power supply. The Scalar i80 can have up to two power supplies for redundancy purposes.

An unused power supply slot must be covered by a filler plate.

This document covers:

• Replacing a Power Supply in a Single-Power-Supply System (Scalar i40 and Scalar i80)

• Adding or Replacing a Redundant Power Supply on the Scalar i80

Figure 60 Single Power Supply System Scalar i40, single power

supply

Scalar i80, single power supply installed in top slot

Filler plate covers empty power supply slot

126 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 153: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Installing a Power Supply

Figure 61 Redundant Power Supply System

Replacing a Power Supply in a Single-Power-Supply System (Scalar i40 and Scalar i80)

Note: If you have a single power supply in a Scalar i80, it is recommended that you install it in the upper slot, to provide better temperature control (see Figure 60).

1 Shut down the library (from the operator panel, select Actions > Shutdown > Shutdown Library). Wait for the screen to prompt you to turn off library power.

2 Turn OFF library power by pressing the power button on the front panel. Wait for the operator panel screen to turn off.

3 Disconnect the power cord from the power supply.

Caution: Make sure you disconnect live power from the power supply before you remove or install it. Otherwise, damage to the power supply could occur.

4 Unscrew the two captive thumbscrews on the power supply.

5 Using the handle, slowly pull the power supply straight out of the library.

6 Install the new power supply by pushing it straight in to the slot. You may need to press firmly on the power supply sheet metal at the very end to plug in the power supply to the connector on the library. You will feel it snap into place.

The power supply only goes in one way, and should slide in easily. If you cannot slide it in, you may be trying to install it upside down.

7 Tighten the two thumbscrews finger tight.

Scalar i80, dual power supplies for redundancy

Quantum Scalar i40 and Scalar i80 Maintenance Guide 127

Page 154: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Installing a Power Supply

8 Connect the power cord to the power supply.

9 Make sure the power cord is plugged in to a grounded, AC outlet.

10 The power supply LED should turn amber to indicate it is plugged in but the library is not turned on.

11 Turn ON library power by pressing the power button on the front panel.

The power supply LED should turn green immediately to indicate the library is turned on.

If the power supply LED is red, the power supply is not working. Contact Quantum Support.

Adding or Replacing a Redundant Power Supply on the Scalar i80

You do not need to turn off library power to perform this procedure.

1 If you are adding a new power supply to a Scalar i80, remove the filler plate and start at Step 6 below.

2 If you have two power supplies, determine which one to remove.

Caution: Make sure you remove the power supply whose LED is red or off. Do not remove the power supply whose LED is green.

3 Disconnect the power cord from the power supply you want to remove.

Caution: Make sure you disconnect live power from the power supply before you remove or install it. Otherwise, damage to the power supply could occur.

4 Unscrew the two captive thumbscrews on the power supply.

5 Using the handle, slowly pull the power supply straight out of the library.

6 Install the new power supply by pushing it straight in to the space. You may need to press firmly on the power supply sheet metal at the very end to plug in the power supply to the connector on the library. You will feel it snap into place.

128 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 155: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

The power supply only goes in one way, and should slide in easily. If you cannot slide it in, you may be trying to install it upside down.

7 Tighten the two thumbscrews finger tight.

8 Connect the power cord to the power supply.

9 Make sure the power cord is plugged in to a grounded, AC outlet.

The power supply LED should turn green immediately to indicate the library is turned on.

If the power supply LED is red, the power supply is not working. Contact Quantum Support.

Removing and Replacing the System Control Board

These instructions explain how to remove a system control board (SCB) and replace it with a new one.

The SCB contains library firmware, tape drive firmware, all configurable settings, license keys, and SKM TLS certificates. After you replace the SCB, you must either restore a previously saved configuration, or reinstall the license keys and manually reconfigure the settings.

Note: When you replace the SCB you will permanently lose all data previously collected for logs and reports.

The process steps are:

1 Replacing the System Control Board

2 Installing Library Firmware

3 Restoring the Library Configuration or Manually Reconfiguring the Library

Replacing the System Control Board

Caution: You must completely remove the power cord from the library before removing and replacing the system control board. Simply shutting down the library is not enough.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 129

Page 156: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

1 If the library is still operational, save the library configuration. From the Web client, select Tools > Save/Restore Configuration. Select Save Configuration and click Apply. Save the configuration to a known location.

2 If the library is still operational, and you want to save log and report information for historical purposes, access the logs and reports you want using the Web client and save them to a known location.

3 If possible, save a library snapshot for future troubleshooting. From the Web client, select Tools > Capture Snapshot and follow the instructions.

4 If the library is still operational, shut down the library by selecting Actions > Shutdown > Shutdown Library from the operator panel.

5 When prompted, turn OFF the library by pressing the power button on the front panel. Wait for all the LEDs on the SCB to turn off.

6 Disconnect the power cords from the power supplies on the back of the library. The Scalar i40 has one power supply. The Scalar i80 may have one or two power supplies. Make sure you disconnect all power cords from the power supplies.

7 Remove the Ethernet cable from the SCB (see Figure 62 on page 131).

8 Loosen the two captive thumbscrews on the SCB.

9 Grip the thumbscrews and pull outward to slide the SCB out of the library.

10 Remove the new SCB from its packaging. Wrap the old SCB in the antistatic bag that the replacement SCB was wrapped in.

11 Position the new SCB for installation as follows: The board components face up. The flat part of the board faces down. The thumbscrews are on the upper side of the SCB back plate (see Figure 62 on page 131).

12 Install the new SCB by pushing the SCB into the slot until it stops. It should slide smoothly and easily. When it reaches the end of its travel, press firmly on the back panel of the SCB to “snap” it into place.

13 Tighten the two thumbscrews finger tight.

14 Connect the Ethernet cable to the LEFT Ethernet port on the SCB (as viewed from the back of the library; see Figure 62 on page 131).

130 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 157: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

Figure 62 Ethernet Port Locations on the SCB

15 Continue to Installing Library Firmware on page 131.

Installing Library Firmware

1 Connect the power cords to the power supplies on the back of the library. Make sure that each power supply is plugged in to a grounded, AC outlet.

2 Turn ON the library by pressing the power button on the front panel.

The LED on the SCB should illuminate green.

The green power LED on the library front panel above the power button illuminates, and the operator panel screen turns on. The library goes through a connection and initialization sequence that takes up to 60 seconds.

Ethernet port

Scalar i40

Scalar i80

Thumbscrews

Thumbscrews

Ethernet port

Quantum Scalar i40 and Scalar i80 Maintenance Guide 131

Page 158: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

3 When initialization is complete, the Library Installation screen appears on the operator panel, displaying the text, “The library needs to have its IP Address configured.” The purpose of this screen is to set the IP address so you can access the library via the Web client and download firmware. (After you have loaded firmware, you can change or reconfigure IP addresses if needed.)

4 Press Next.

The screen displays the text, “Current protocol: IPv4. Set protocol to IPv6?”

5 Select Yes or No.

• If you select Yes, the library supplies a stateless IPv6 address and displays it, along with other network settings, on two screens. Use the Next and Back buttons to view the screens. You can only change these settings via the Web client.

• If you select No, you are asked if you want to use DHCP.

• If you select Yes, the library assigns IPv4 address and displays the information on the screen.

• If you select No, use the Up and Down buttons to enter the IP address, mask, and gateway. Set the numeric value for each segment of the address, then press the Right button to go to the next segment. See the Scalar i40 and Scalar i80 User’s Guide for more information on editing the IP address. When finished, press Apply.

6 Take note of the IP address and log into the Web client using this IP address.

7 Download the latest library firmware using one of the following methods:

• If the library has an internet connection, use the Web client to update the library to the latest firmware.

a Click Tools > Update Library Firmware.

b Read the EULA agreement.

c Click Update library firmware with the version from the Quantum Support Web site check box.

d Click Apply.

132 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 159: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

• If the library does not have an internet connection, do the following:

a Using a Web browser connected to the internet go to http://www.quantum.com/ServiceandSupport/SoftwareandDocumentationDownloads/SI40/Index.aspx and click the Firmware tab.

b Download the library firmware to a known location on your computer.

c Using the Web client, go to Tools > Update Library Firmware

d Click Browse to select the firmware image you downloaded.

e Click Apply.

Note: For a “limited control release,” go to the CS Web site to download the appropriate library firmware version.

8 Go to the operator panel and wait until the Setup Wizard appears on the screen. The Setup Wizard screen may take up to 20 minutes to appear.

9 Continue as follows:

• If you have saved a library configuration that you want to restore on the library, go to: Restoring the Library Configuration on page 133.

• If you do NOT have a saved library configuration to restore on the library, go to: Manually Reconfiguring the Library on page 135.

Restoring the Library Configuration

Follow the instructions in this section if you have a saved library configuration that you want to reinstall on the library.

1 On the operator panel, press Cancel to exit the Setup Wizard.

2 Take note of the library’s IP address (on the operator panel, select Reports > Network Settings).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 133

Page 160: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

3 Access the Web client using the IP address and log in using the default user name and password:

• User name: admin

• Password: password

Note: Once you restore the configuration, all your former user names and passwords are restored.

4 Restore the configuration using the Web client as follows:

a Select Tools > Save/Restore Configuration.

b Select Restore System Configuration.

c Click Browse. Navigate to the saved configuration and click Open.

d Click Apply

e Click OK.

Note: Restoring the configuration does NOT restore your network settings.

5 Check the library’s date, time, and time zone settings and reconfigure if necessary. From the Web client, select Setup > Date & Time.

6 If you changed the IP address from what it was originally, update host and other applications that access the library.

7 Save the library configuration. From the Web client, select Tools > Save/Restore Configuration. Select Save Configuration and click Apply. Save the configuration to a known location.

8 It is recommended that you run the Installation and Verification Test (IVT). From the operator panel, select Tools > IVT and follow the instructions on the screen. The IVT takes about 30 minutes. See Running the Installation and Verification Test (IVT) on page 211 for more information about the IVT. If any problems are detected, the library issues a diagnostic ticket.

9 Package the old SCB in the packaging that shipped with the new SCB and send the old SCB back to Quantum using the included return shipping label.

134 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 161: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

Manually Reconfiguring the Library

Follow the instructions in this section if you do not have a saved library configuration.

1 If you had licenses installed on your library, have the license keys handy so you can install them on the library. If you no longer have them, you can obtain them at http://www.quantum.com/licensekeys, or from Quantum Support.

2 When the firmware update is complete, the Setup Wizard appears on the operator panel screen. The Setup Wizard helps you configure the date, time, IP address, IPv6 enable/disable, licenses, partitions, I/E slots, and cleaning slots.

3 Complete the Setup Wizard on the operator panel. If you make a mistake or do not complete all the screens, you can change the configuration later using the operator panel or Web client Setup menus.

Note: You cannot update the library name or time zone on the operator panel. If the displayed library name or time zone is incorrect, change it later using the Web client (see Step 8 on page 136).

4 Take note of the library’s IP address (on the operator panel, select Reports > Network Settings).

5 Access the Web client using the IP address and log in using the default user name and password:

• User name: admin

• Password: password

6 Optionally, install tape drive firmware for autoleveling. The library firmware contains baseline tape drive firmware for autoleveling. Verify your tape drive firmware is at the level you expect. If not:

a Upload the tape drive firmware you want to use. From the Web client, select Tools > Drive Operations > Upload/remove tape drive firmware for autoleveling.

b Unload all tape cartridges from the tape drives on which you want to autolevel firmware.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 135

Page 162: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing the System Control Board

c Initiate autoleveling by doing one of the following:

• Restart the library (from the operator panel, select Actions > Shutdown > Restart Library.

• Restart all the tape drives you want to autolevel, as follows:

- If you are logged in as Service, select Drives > Drive Tests > Drive Reset. Select the applicable partitions and tape drives, then click Apply, then click OK.

- If you are logged in as Admin, from the Web client, select Tools > Diagnostics. Confirm you want to take the partitions offline. Select the applicable partitions and tape drives, then click Apply, then click OK.

7 If you changed the IP address from what it was originally, update host and other applications that access the library.

8 Update the library name, time zone, and any other configuration settings, if required, using the Web client Setup menus.

9 If you are connecting to a Scalar Key Manager (SKM), take note that TLS certificates will need to be loaded onto the library. For instructions, refer to the Scalar i40 and i80 User Guide, Installing TLS Certificates on the Library.

10 Save the library configuration. From the Web client, select Tools > Save/Restore Configuration. Select Save Configuration and click Apply. Save the configuration to a known location.

11 To ensure the library is fully functional with the new SCB installation and configuration selections, we recommend you run the Installation and Verification Test (IVT). From the operator panel, select Tools > IVT and follow the instructions on the screen. The IVT takes about 30 minutes. See Running the Installation and Verification Test (IVT) on page 211 for more information about the IVT. If any problems are detected, the library issues a diagnostic ticket.

12 Package the old SCB in the packaging that shipped with the new SCB and send the old SCB back to Quantum using the included return shipping label.

136 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 163: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Tape Drive

Removing and Replacing a Tape Drive

It is recommended that you remove and install tape drives with library power ON — it is faster and keeps non-affected tape drives and partitions active.

The tape drive always resides in a drive sled, and together they are effectively one unit. If you order a new or replacement tape drive, it will already be installed in a sled.

Caution: Do not remove the tape drive from the drive sled.

Note: For multiple tape drive installs in which you are changing control paths, install and verify the tape drives one at a time, rather than all at once.

Preparing Partitions and Control Paths

Depending on the types of tape drives you are removing and installing, you may need to reconfigure library partitions or change the control path before you remove and replace the tape drive. There are four different types of installation, described in the table below. Follow the instructions in the table before proceeding to the remove/install procedures.

Type of Installation Instructions

Adding a new tape drive No special instructions.

Replacing a tape drive that is not assigned to a partition

No special instructions.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 137

Page 164: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Tape Drive

Removing a Tape Drive from the Library

Caution: Do not remove a tape drive that is currently performing an operation.

1 Make sure the tape drive you want to remove is empty. From the operator panel, select Actions > Tape Drive > Unload.

2 Take the tape drive you want to remove offline. From the operator panel, select Actions > Tape Drive > Change Mode. Select the tape drive and press Modify. Press the Down button to select Offline, then press Apply.

3 Disconnect the cable from the back of the tape drive.

Replacing tape drive that is assigned to a partition with a tape drive that has the same:• interface type (Fibre

Channel or SAS), and• form factor (half-height or

full-height), and• vendor

Install the replacement tape drive in the same slot as the removed tape drive.There are no special instructions unless the tape drive you are replacing is the control path in a partition with multiple tape drives, and you want the partition to remain online during the replacement procedure. In this case, select another tape drive as the control path. From the Web client, use the Setup > Control Path menu path.

Replacing a tape drive that is assigned to a partition with a tape drive that has a different:• interface type (Fibre

Channel or SAS), or• form factor (half-height or

full-height), or• vendor

• If the partition contains only one tape drive, delete the partition before removing the tape drive and then re-create the partition once you install the replacement tape drive.

• If the partition contains multiple tape drives and the tape drive you want to replace is not the control path, delete the tape drive from the partition.

• If the partition contains multiple tape drives and the tape drive you want to replace is the control path, select another tape drive as the control path. Then delete the tape drive you want to replace from the partition.

To delete tape drives from partitions, select Setup > Partitions from the Web client. To modify the control path, select Setup > Control Path from the Web client.

Type of Installation Instructions

138 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 165: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Tape Drive

4 Unscrew the captive thumbscrews securing the drive sled to the back of the library. Half-height tape drives have two thumbscrews. Full-height tape drives have four thumbscrews.

5 Using the handle, pull the drive sled out of the library. It should slide out smoothly and easily.

6 Wait at least 10 seconds before installing a replacement tape drive to allow the library to recognize that the tape drive has been removed.

7 Install a replacement tape drive following the instructions below. If any empty slots remain, install a filler plate in the empty slot.

8 If you are returning the tape drive to Quantum, wrap it in the antistatic bag in which the replacement tape drive is wrapped, then finish packing it in the same packaging materials from the replacement tape drive. Ship the tape drive to Quantum using the RMA materials included in the packaging.

Installing a Tape Drive Tape Drive Slot Location Considerations

Tape drives can only fit in certain slots, as described below and illustrated in Figure 63. Slots are numbered starting from the bottom and moving up.

• Scalar i40: Half-height tape drives can be installed in slots 1 and 2. A full-height tape drive can be installed in slot 1.

• Scalar i80: Half-height tape drives can be installed in slots 1, 2, 3, 4, and 5. Full-height tape drives can be installed in slots 1, 3, and 5. The extra space where slot 6 would be cannot hold a half-height tape drive, but will accommodate a full-height tape drive installed in slot 5.

If possible, it is recommended to start installing the tape drives at the bottom slot and work up, without leaving spaces between.

If you are replacing an existing tape drive with a tape drive of the same interface type, form factor, and vendor, place the replacement tape drive in the same slot as the removed tape drive.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 139

Page 166: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Tape Drive

Figure 63 Acceptable Installation Locations for Full-Height Tape Drives

Installation Procedure

1 If you need to remove one or more filler plates, unscrew the two thumbscrews securing the filler plate to the back of the library. Holding the thumbscrews, pull the filler plate gently out of the library. Save the filler plate in case you need to use it in the future.

2 Insert the tape drive into the drive slot. The “shelf” on the bottom of the drive sled fits into the notch in the library chassis and slides on the plastic guide rails (see Figure 64 on page 141). The tape drive must be level to slide in smoothly. At the very end of the slide, you will feel a slight “click” as the tape drive sled connector connects into its mating connector in the library chassis.

Scalar i40 Scalar i80

140 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 167: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Tape Drive

Figure 64 Installing a Tape Drive

3 Tighten the tape drive’s captive thumbscrews finger tight to secure the tape drive to the library chassis.

The tape drive LED illuminates red for up to 30 seconds. Then the tape drive fan starts and the LED turns amber, indicating the tape drive is offline. If this is a new installation (not a replacement), the tape drive will come online automatically.

4 Connect the tape drive cable from the tape drive to the host.

5 If the firmware on the newly installed tape drive is different from the standard configured on the library, the library will automatically autolevel the new tape drive’s firmware upon installation (for more information, see the user’s guide).

Autoleveling takes about 7 minutes. A message appears on the operator panel indicating autoleveling is taking place.

If autoleveling is not required, the tape drive takes about 2 minutes to come ready.

Notch in library chassis

Drive sled “shelf” slides in notch

Quantum Scalar i40 and Scalar i80 Maintenance Guide 141

Page 168: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsRemoving and Replacing a Tape Drive

6 If needed, add the new tape drive to an existing partition or create a new partition for it. From the Web client, select Setup > Partitions and complete the necessary screens.

7 Bring the tape drive online, if it is not online already. From the operator panel, select Actions > Tape Drive > Change Mode. Select the tape drive you want to bring online and press Modify. Use the Up and Down buttons to change the mode to Online, then press Apply.

The tape drive LED turns green.

8 Verify the installation by reviewing the library configuration report on the Web client (Reports > Library Configuration). Make sure that the new drive is online, in the correct partition, and has the control path status that you want. You may need to refresh your Internet browser.

9 Verify that the host computer and backup applications can see the new tape drive configuration correctly.

10 If any empty slots remain, install a filler plate in the empty slot.

Caution: Filler plates are required to maintain proper library cooling. Do not run the library with uncovered slots.

11 Run the tape drive diagnostic test on the newly installed tape drive to be sure it is functioning correctly.

a Install a scratch tape in the top I/E station slot.

b If manual cartridge assignment is enabled, assign the scratch tape to the System partition.

c From the operator panel, select Tools > Diagnostics.

d Continue through the next few screens to run the tape drive test on the replaced tape drive.

If a problem is found during testing, you receive a diagnostic ticket. See Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests on page 213 for more information.

12 Save the library configuration (see Saving the Library Configuration on page 33).

142 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 169: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsPackaging the Library for Moving or Shipping

Packaging the Library for Moving or Shipping

Packaging Kit Contents • Shipping box

• Top foam

• Bottom foam

• Anti-static wrapping

• (4) M5 Thumbscrews to restrain Y-tray

• Bottom tray (Scalar i80 only)

• Pallet (Scalar i80 only)

• (2) Cardboard “corner boards” (Scalar i80 only)

• (2) Straps and buckles for securing packaging to pallet (Scalar i80 only)

Creating a Backup Map of Cartridge Locations

You must remove all the tape cartridges before shipping the library. If you want to maintain the same partitions and magazine slot assignments in your new location as you are using currently, you will want to reinstall your tape cartridges in the same slots they are in now. The library configuration report provides a convenient “map” of your slot assignments. If you print or copy this map, you will be able to easily install your cartridges later.

1 On the Web client, select Reports > Library Configuration.

2 Click the Show Barcodes button.

The screen displays a map of the library showing the partitions and the location of each cartridge, by barcode.

3 Click the “print” icon in the upper right corner to print the report.

Alternatively, take a screen capture of the report and save or print it, or copy the map by hand.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 143

Page 170: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsPackaging the Library for Moving or Shipping

Procedure 1 As a precautionary measure, save the library configuration: From the Web client, select Tools > Save/Restore Configuration. Select Save System Configuration and click Apply. When prompted, save the file to a known location on your computer.

2 Stop all library and host operations.

3 Remove the magazines from the library:

a From the operator panel, select Actions > Magazine.

b Use the Up and Down buttons to select the magazine you want to remove and press Release.

c Wait for the operator panel to display the message: “Magazine is now unlocked. Waiting for the magazine to be moved to the expected position.”

d Pull the magazine bezel out and remove the magazine from the library. If you do not remove the magazine within 30 seconds, the magazine locks again.

e Repeat for all magazines in the library.

Caution: Do not put your hands or any other objects into the magazine openings while library power is on.

4 Remove all the tape cartridges from the magazines.

5 Shut down the library by selecting Actions > Shutdown from the operator panel. Wait for the operator panel to prompt you to turn off library power.

6 Turn OFF the library by pressing the power button on the front panel. Wait for the LED on the SCB to turn off.

7 Disconnect the power supply cord, the Ethernet cable, and all tape drive cables from the back of the library. If you have multiple tape drives, label the cables so you can reconnect them to the correct ones later.

8 If the library is in a rack or desktop kit, remove it.

• To remove the library from a rack:

a Remove all the tape drives from the library. Label tape drives so you know what order to reinstall them later. They must be reinstalled in the same slots as they were previously.

144 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 171: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsPackaging the Library for Moving or Shipping

Unscrew the thumbscrews and pull the tape drive handle to remove the drive from the library.

b Unscrew the captive thumbscrews on the front of the library that secure the library to the rack, then slide the library out of the rack. Place the library on a flat, stable surface.

WARNING: Two people are required to safely remove the library from the rack.

• To remove the library from a desktop kit, remove the two screws in the decorative top cover. Remove the decorative top cover by sliding it toward the back. Loosen the captive thumbscrews on the library chassis that are attached to the side panels of the desktop kit. Slide the side panels one inch toward the rear of the library, then pull the side panels off.

9 Make sure the Y-tray is sitting on the floor of the library as follows: Look inside the library through one of the magazine openings. If the Y-tray is not sitting on the floor of the library, reach inside and gently press down on one of the Y-tray’s metal side rods until the Y-tray starts moving. It should drift down to rest on the floor of the library.

10 Reinstall the empty magazines in the library by pushing them in until they stop.

11 If you removed the tape drives earlier, reinstall them in their proper slots. Push them carefully into their slots and tighten the captive thumbscrews.

12 Restrain the Y-tray as follows (see Figure 65 on page 146):

a Turn the library carefully on its side (either the left or right side). Make sure the front end of the library (the “rack ear”) overhangs the edge of the table so that the library lies flat.

Caution: Do not turn the library upside down. Do not turn the library more than 90 degrees from upright.

b Install four thumbscrews into the floor of the library in the locations shown in Figure 65 on page 146. They will screw through the Y-tray and hold it in place on the floor of the library.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 145

Page 172: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsPackaging the Library for Moving or Shipping

Figure 65 Restraining the Y-tray

c Do NOT turn the library back to an upright position at this point. Leave it on its side until you place it in the box.

Caution: If you place the library upright with the Y-tray restraint thumbscrews installed, you could damage the chassis or the Y-tray.

13 Wrap the library in the anti-static wrapping provided in the packaging kit.

WARNING: Two people are required to safely lift the library.

Four Y-tray restraint thumbscrews

Rack “ear” overhangs edge of desk or table

146 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 173: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsPackaging the Library for Moving or Shipping

14 Place the library in the packaging as shown in Figure 66 and Figure 67.

Figure 66 Scalar i40 Packaging

Top foam

Library (anti-static wrap not shown

for clarity)

Bottom foam

Shipping carton

Quantum Scalar i40 and Scalar i80 Maintenance Guide 147

Page 174: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 3: Installing, Removing, and Replacing CRUsPackaging the Library for Moving or Shipping

Figure 67 Scalar i80 Packaging

15 Scalar i80 only: Place two corner boards on the long edges on top of the shipping carton, then strap the box to the pallet. It is recommended that you wrap the entire assembly in stretch-film (not supplied) prior to shipping.

Unpacking the Library in its New Location

Caution: When unpacking the library in its new location, lift it out of the packaging and immediately place it on its side to remove the four thumbscrews securing the Y-tray to the floor of the library. Do not place it upright until you have removed the four thumbscrews, or you could damage the chassis or the Y-tray. When placing the library on its side, do not set it on the “rack ear” or the magazine handle, or you could damage them.

Top foam

Library (anti-static wrap not shown

for clarity)

Bottom foam

Shipping carton

Bottom tray

Pallet

148 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 175: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4Installing, Removing, and

Replacing FRUs

Field replaceable units (FRUs) are components that can only be replaced by a field service engineer. The only FRU on the Scalars i40 and Scalar i80 is the Y-tray.

Replacing the Y-tray with Robot

The procedure is the same for the Scalar i40 and the Scalar i80. The pictures show just the Scalar i40.

Caution: Only qualified service technicians should perform this procedure.

Caution: Read through and understand the entire procedure before beginning work.

Caution: Make sure the library is on a flat, level surface. The library must be level during installation of a new Y-tray.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 149

Page 176: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Tools Required • Small Phillips screwdriver

• Magazine lock override tool — an opened paperclip, small screwdriver, or other object (3.5 mm or less in diameter that will not break off)

Y-tray FRU Kit Contents • (1) Y-tray

• (1) 3U Y-axis flex cable (for the Scalar i40)

• (1) 6U Y-axis flex cable (for the Scalar i80)

• (2) White strain relief clips for library bulkhead

Taking ESD Precautions To avoid damaging static-sensitive parts while performing this procedure, observe the following precautions:

• Use an antistatic wrist strap. If you do not have one, touch the outside of the library on the sheet metal before touching any components to discharge static from your body.

• Keep static-sensitive parts in their original shipping containers until ready for installation. Look for the ESD sticker to identify static sensitive parts.

Note: Dry climates and cold-weather heating environments have lower relative humidity and are more likely to produce static electricity.

Removing the Y-tray 1 Shut down the library by selecting Actions > Shutdown from the operator panel. Wait for the operator panel to prompt you to turn off library power.

150 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 177: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

2 Turn OFF the library by pressing the power button on the front panel. Wait for the LED on the SCB to turn off.

3 Do one of the following:

Quantum Scalar i40 and Scalar i80 Maintenance Guide 151

Page 178: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

If the library is... Do the following...

Installed in a rack

Remove the library from the rack and place it on a flat, stable surface as follows:

WARNING: Two people are required to safely lift the library into and out of a rack.

1 Disconnect all cords and cables from the back of the library (power supplies, SCB, and tape drives).

Note: If you have multiple tape drives, label the cables so you can re-connect them to the same tape drives later.

2 Remove all tape drives from the library. Unscrew the captive thumbscrews and gently pull the tape drives out of the library.

Note: Label the tape drives so you can reinstall them in the same slots later.

3 Remove all the magazines from the library as follows.

Note: For a Scalar i80, label the magazines so you can reinstall them in the same slots.

Insert the magazine lock override tool into the access hole in the bottom of the magazine bezel (see Figure 68 for location). Use the tool to depress the release latch while gently pulling outward on the magazine bezel handle. If the magazine is on the right side, it will only slide out as far as the I/E station. To release the magazine fully:

• On the Scalar i40 and the bottom right magazine of the Scalar i80, reach under the open magazine and insert the tool directly into the access hole in the library chassis to depress the release latch, while pulling out on the magazine bezel handle.

• On the top magazine of the Scalar i80, reach under the open magazine and press the release latch directly with your finger, while pulling out on the magazine bezel handle.

4 Unscrew the captive thumbscrews on the front of the library that secure the library to the rack, then slide the library out of the rack and place it on a level surface about waist high.

152 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 179: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Caution: Make sure the library is on a flat, level surface. The library must be level during installation of a new Y-tray.

4 Using a small Phillips screwdriver, remove and save the 24 screws that secure the top cover of the library. There are 10 screws on the top of the library, and 7 screws on both the left and right sides of the top cover (see Figure 68).

Installed in a desktop kit

1 Remove the top cover of the desktop kit. Unscrew two Phillips screws from the back of the library and set aside. Slide the cover of the desktop kit toward the back of the library until it slides off.

2 Remove the two side panels of the desktop kit. Unscrew the captive thumbscrew behind the each magazine bezel to detach the side panels. To access the thumbscrews, you must open the magazines a few inches. Insert the magazine lock override tool into the access hole in the bottom of the magazine bezel (see Figure 68 for location). Use the tool to depress the release latch while gently pulling outward on the magazine bezel handle.

3 Disconnect the power cord from the power supply on the back of the library.

If the library is... Do the following...

Quantum Scalar i40 and Scalar i80 Maintenance Guide 153

Page 180: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 68 Top Cover Screw Locations

5 Carefully lift off the top cover of the library.

6 Look at the position of the picker carriage on the Y-tray. It needs to be in a particular position and orientation or it will not fit in the shipping packaging. If it is not in the proper position, you should move it into the proper position now, before you remove the Y-tray from the library. You may need to make adjustments to the position once the Y-tray is in the packaging, but it is easier to do it while the Y-tray is still in the library.

7 This step contains an explanation of the proper position, followed by Figure 69, which shows the proper position and orientation of the Y-tray in its packaging. If you need to move the picker, follow the instructions in the sections indicated below.

Magazine release latch access hole

Ten screws on top

Seven screws on each side

154 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 181: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

• The picker arms must be parallel to the front of the library. For instructions, see Swiveling the Picker (Theta Axis) on page 175.

• The picker must be near the center of the robot’s X-axis, so that, when placed in the packaging, the picker carriage is cradled by the two foam squares on the underside of the top foam. For instructions, see Moving the Picker Along the Robot X-axis on page 178.

• The picker fingers may point down or inward, it does not matter.

Figure 69 Y-tray in Packaging

Two foam squares on underside of top foam cradle the picker carriage

Quantum Scalar i40 and Scalar i80 Maintenance Guide 155

Page 182: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

8 Make sure the Y-tray is sitting on the floor of the library. If not, gently press down on one of the Y-tray’s side metal rods until the Y-tray starts moving. It should drift down to rest on the floor of the library.

9 Detach the white strain relief clip(s) that secure the Y-axis flex cable to the bulkhead of the library. The strain relief clip is located inside the library at the back, between the tape drives and the power supply. The strain relief clip is attached to the cable and will hang loosely from the cable once you detach it. See Figure 70. The Scalar i40 has one strain relief clip; the Scalar i80 has two.

156 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 183: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 70 Bulkhead Inside Library, Y-axis Flex Cable

Top hole in bulkhead through which cable is threaded

Y-axis flex cable

Strain relief clip

Scalar i40

Scalar i80

Strain relief clip

Top hole in bulkhead through which cable is threaded

Quantum Scalar i40 and Scalar i80 Maintenance Guide 157

Page 184: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

10 Disconnect the Y-axis flex cable from the back plane of the library (see Figure 71). The connection is located on the opposite side of the inner library wall from the strain relief clip(s) you detached in the previous step.

Figure 71 Y-axis Flex Cable Connection on Library Back Plane

11 Thread the Y-axis flex cable through the top hole in the bulkhead (see Figure 70 and Figure 71).

Y-axis flex cable connected in to back plane of library

Top hole in bulkhead through which cable is threaded

158 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 185: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

12 Gently lay the flex cable on top of the robot (see Figure 72).

Figure 72 Flex Cable on Robot

Quantum Scalar i40 and Scalar i80 Maintenance Guide 159

Page 186: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

13 Place your index fingers under the two designated lift tabs on the front and rear of the Y-tray (see Figure 73). The lift tabs have orange stickers on them to identify them. Gently lift the Y-tray up until it is disengaged from the gears. Lift the Y-tray out of the library and set it down carefully on a flat, level surface.

Caution: Lift the Y-tray only by the two designated lift tabs. Lift up at both locations simultaneously and keep the Y-tray level as you lift. Do not tilt or twist the Y-tray.

160 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 187: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 73 Y-tray Lift Tabs

Front lift tab

Front of library

Rear lift tab

Quantum Scalar i40 and Scalar i80 Maintenance Guide 161

Page 188: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Installing the Y-tray 1 Remove the top foam from the replacement Y-tray and place it upside-down on a desk or table.

2 Remove the replacement Y-tray and turn it upside-down, placing it into the upside-down top foam (see Figure 74).

3 Remove the four thumbscrews and two plastic strips from the bottom of the Y-tray (see Figure 74). Save these to use on the removed Y-tray later.

Figure 74 Removing Thumbscrews and Plastic Strips from Bottom of Y-tray

4 Turn the replacement Y-tray upright and place it carefully on a flat, level surface.

5 Remove the two Y-axis flex cables from the box and select the one that is appropriate for your library. For a Scalar i40, choose the cable marked “3U.” For a Scalar i80, choose the cable marked “6U.”

Caution: Be sure you select the cable that is appropriate for your library. If you use the wrong cable, you could damage the library.

162 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 189: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

6 Connect the Y-axis flex cable to the adapter board on the Y-tray as follows.

Caution: Do not twist or kink the cable.

a Unlock the ZIF connector on the Y-tray adapter board (push up on the locking mechanism; see Figure 75).

b Make sure the cable orientation is correct.

• There is a blue stiffener on one side of the cable. The electrical contacts are on the other side of the cable. The blue stiffener should face you when you push the end of the cable into the ZIF connector (see Figure 75).

• The cable is folded. The long side of the cable should face toward you, and the short side faces the board so that when you plug it in, the cable hangs down as shown in Figure 77.

c Push the cable into the ZIF connector. There is a black alignment mark at the end of the cable, on the blue stiffener. Push the flex cable in until the black alignment mark disappears.

d Make sure you install the connector straight (perpendicular). This is indicated by the blue stiffener. It should be straight and not angled (see Figure 76).

e Lock the ZIF connector (push down with your finger or fingernail).

Caution: If you install the cable crooked, the cable might short out and become damaged. If this happens, the cable may start to smoke. If you see smoke, shut off the library and order a new Y-tray FRU. You will need to replace the entire Y-tray assembly.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 163

Page 190: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 75 Y-tray Adapter Board

Figure 76 Connecting the Flex Cable

Blue stiffener faces out. Must be straight.

Black alignment mark - insert connector up to the line

ZIF connector - push up to unlock; push down to lock

Blue stiffener angled - WRONG Blue stiffener straight - CORRECT

164 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 191: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

7 Secure the Y-axis flex cable with a strain relief clip, following one of the two scenarios described below.

• Scenario One: There is no strain relief pre-installed on the Y-tray adapter board: Install the strain relief clip (provided in the kit) onto the replacement Y-tray adapter board, securing the Y-axis flex cable. Snap in both sides. Discard the old strain relief clip. See Figure 77.

Caution: Use the new white strain relief clip provided in the kit. Do not reuse the old clip as it may be defective.

Figure 77 Strain Relief on Y-tray Adapter Board

Strain relief clip

Quantum Scalar i40 and Scalar i80 Maintenance Guide 165

Page 192: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

• Scenario Two: A strain relief is pre-installed on the Y-tray adapter board: Open the strain relief clip from the right side, place the Y-axis flex cable inside the clip, and close the top of the clip, pressing the right side in firmly so that it locks into place. See Figure 78. Note: Color of the clip may vary.

Figure 78 Strain Relief on Y-tray Adapter Board

8 Lay the flex cable gently on top of the Y-tray as shown in Figure 72 on page 159.

9 Adjust the Y-climber gears into the proper position. There are four Y-climber gears. If one is in the proper position, all will be, so you only need to check one of the gears. You can adjust the Y-climber gear by rotating the Y-axis transmission gear that is located closest to the back of the library. See Figure 80 on page 168.

Note: The Y-climber gear must be in the proper position or the Y-tray will not lower into the library correctly. This is a “keying” feature that makes sure the Y-tray is aligned properly as it moves up and down.

Strain relief clip

166 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 193: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

The following descriptions, along with Figure 79 and Figure 80, will help you orient the gear properly:

• The two flat sides of the Y-climber gear must be vertical.

• The tab boss must be pointing in a downward direction. Depending on which gear you are looking at, it should either be in the “5 o-clock” position or the “7 o’clock” position.

• The center of the gear, when viewed head on, presents a “smiley face” appearance. The partial circle in the center is round at the bottom and horizontal at its top.

Figure 79 Y-climber Gear in Proper Position

Flat sides vertical

“Smiley face”

Tab boss in 5 o’clock or 7 o’clock position (depends on the gear)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 167

Page 194: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 80 Y-climber Gear in Proper Position and Y-axis Transmission Gear

Y-climber gear - flat side is vertical

Tab boss points in a downward direction, 5 o-clock or 7 o-clock

Y-climber gear - flat side is vertical

Turn the gear located closest to back of library. Turn the gear toward the back of the library.

Y-axis transmission gears

Y-climber gear

“Smiley face”

168 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 195: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

10 Using the lift tabs shown in Figure 73, lift the Y-tray and gently set it into the top opening of the library. Take care not to snag the flex cable or drop the cable or Y-tray into the library. Set the Y-tray in lightly so you don't skip a tooth. The Y-tray should settle into position. Make sure it looks level.

11 The Y-tray may start moving downward on its own. If it does not, use your fingers to rotate the Y-axis transmission gear that is closest to the back of the library (see Figure 80 on page 168). Rotate the gear toward the back of the library. The Y-tray should start to move downward on its own shortly after you start to rotate the gear.

Note: The Y-axis transmission gear has a “spring loaded” feel. Once you move it about one-eight of a rotation, if you let go of the gear, it will spring back to its original position, and the Y-tray will move back up. It may be best to use two fingers to rotate the Y-axis transmission gear—one finger to rotate the gear and the other finger to hold the gear in place—so that the gear doesn’t spring back.

Caution: If the Y-tray does not drift downward on its own after one revolution of the Y-axis transmission gear, do not force it further. Lift up on the lift tabs, remove the Y-tray from the library, and re-examine the tab boss orientation. Start again at Step 9 on page 166.

12 Thread the Y-axis flex cable through the top hole in the bulkhead (see Figure 82).

Caution: Do not pull the cable over the top of the bulkhead. The cable must be threaded through the hole as shown.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 169

Page 196: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

13 Plug the Y-axis flex cable into the socket on the library’s back plane (see Figure 81 on page 170).

Figure 81 Y-axis Flex Cable Connection on Library Back Plane

14 Snap in the new white strain relief clip(s) (provided in the kit) on the inside of the library bulkhead in the locations shown in Figure 82 on page 171. The strain relief goes through the two holes in the clear plastic attached to the Y-axis flex cable. The Scalar i40 uses one strain relief; the Scalar i80 uses two.

Y-axis flex cable connected in to back plane of library

Top hole in bulkhead through which cable is threaded

170 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 197: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 82 Y-axis Flex Cable and Strain Relief Installed on Bulkhead

Top hole in bulkhead through which cable is threaded

Y-axis flex cable

Strain relief clip

Scalar i40

Scalar i80

Strain relief clip

Top hole in bulkhead through which cable is threaded

Quantum Scalar i40 and Scalar i80 Maintenance Guide 171

Page 198: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

15 Perform a power-up test to verify Y-tray functionality, as follows:

a Connect the power cord to the power supply on the back of the library. Plug in the other end of the cord to a grounded AC outlet.

b Press the power button on the front panel of the library.

c Confirm that the X-axis encoder on the front of the robot glows bright red. The X-axis encoder is located behind the library front panel, on the right side as you face the front of the library (see Figure 83). If the X-axis encoder does not light up, turn off the library, unplug the power cord, and re-check the Y-axis cable connections.

d The robot will start to go through its homing process. Watch it as it moves and make sure that it goes through all of the following directional motions (see Figure 83):

• X-axis: The picker moves from the front to the rear of the library.

• Y-axis: The entire robot moves up and down

• Z-axis: The picker moves back and forth along the width of the Y-tray.

• Theta axis: The robot rotates 180 degrees.

• Picker fingers rotate: You will hear them clicking.

Note: If the robot is unable to complete one or more directional movements, turn off library power and disconnect the power cord. Examine the Y-axis flex cable and make sure it is connected correctly on the library back plane and the Y-tray adapter board.

Note: If the robot starts initializing, it will recognize that tape drives and magazines are missing, and the library will generate diagnostic tickets. If this happens, close the tickets later.

172 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 199: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 83 X-axis Encoder on Robot - Front Inside of Library and Robot Directional Movement

e Once you verify the robot is capable of all the directional movements, turn OFF library power by pressing the power button on the front panel.

f Wait until the LED on the SCB on the back panel of the library turns off, then disconnect the power cord from the power supply.

16 Reinstall the top cover on the library (see Figure 68 for screw locations).

17 Reinstall the library in the rack or desktop kit.

WARNING: Two people are required to safely lift the library into and out of a rack.

18 Reinstall tape drives and magazines into their correct slots.

19 Reconnect the power cord(s), Ethernet cable, and tape drive cables to their original positions on the rear of the library.

X-axis encoder - should glow red when power is on

X-axis

theta axis

Y-axis

Z-axis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 173

Page 200: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

20 Turn ON the library by pressing the power button on the front panel. Wait for the library to complete initialization.

21 Run the Installation and Verification Test (IVT). For instructions, see Running the Installation and Verification Test (IVT) on page 211.

Packing and Shipping the Removed Y-tray

1 Place the removed Y-tray upside down in the upside-down top foam from the packaging (see Figure 74 on page 162).

2 Install the two plastic strips with the four thumbscrews that you removed from the replacement Y-tray earlier (see Figure 74 on page 162).

3 Place the Y-tray right side up in the bottom foam.

4 Turn the top foam right side up and place it over the Y-tray. If you have trouble pushing it down all the way, you may need to adjust the position of the picker. See Moving the Picker Into Proper Position For Shipping on page 174 for instructions.

5 Send the removed Y-tray back to Quantum using the RMA material enclosed in the packaging.

Moving the Picker Into Proper Position For Shipping

This section contains instructions on how to move the picker on the Y-tray to get it in proper position for shipping in the shipping carton. Perform one or more of these procedures (depending on how the picker needs to move), in this order:

1 Swiveling the Picker (Theta Axis) on page 175

2 Moving the Picker Along the Robot X-axis on page 178

Note: Perform these procedures while the Y-tray is still installed in the library.

174 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 201: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Swiveling the Picker (Theta Axis)

The picker swivels 180 degrees. To swivel the picker, lift up on the Theta Release Gear located behind the carriage (the gear has a spring visible on top of it). As you lift the Theta Release Gear, simultaneously press and hold down the top of the screw to stabilize the picker (otherwise you will torque the picker). Holding the Theta Release Gear up and the screw down, swivel the picker. The picker should swivel easily and without resistance. If it does not, then stop. See Figure 84 and Figure 85.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 175

Page 202: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 84 Normal Position of Theta Gear

Theta Release Gear (lift up)

Stabilizing screw (press and hold down)

176 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 203: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 85 Raising the Gear to Swivel the Picker

Raise this gear up

Stabilize by pressing down on this screw

Hold gear and screw in this position as you swivel the picker

Quantum Scalar i40 and Scalar i80 Maintenance Guide 177

Page 204: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Moving the Picker Along the Robot X-axis

Use your hands to slide the picker toward the front or back of the library as necessary.

When pulling/pushing the picker, there are two locations you can use (see Figure 86).

• Push or pull on two of the picker corners where they sit on the metal side rods of the robot. Push or pull on either the two front points or the two rear points at the same time.

• Push or pull on the metal base of the picker. Stay close to the center of the picker to avoid torquing the picker.

Caution: Do not pull on the belt. Do not push or pull on the picker card.

178 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 205: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

Figure 86 Acceptable Locations for Sliding the Picker Along the X-axis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 179

Page 206: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 4: Installing, Removing, and Replacing FRUsReplacing the Y-tray with Robot

180 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 207: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5Getting Information About

the Library

There are a number of informational screens and reports you can use to get information about the library.

This chapter covers:

• Viewing Library Information

• Viewing System Information

• Viewing the Location of the Robot

• Viewing the Library Configuration Report

• Saving and E-mailing the Library Configuration Record

• Viewing the Network Settings Report

• Viewing the Logged in Users Report

• Viewing the All Slots Report

• Viewing, Saving, and E-mailing Library Logs

• Viewing Library Information on the Operator Panel

• Using Advanced Reporting

Quantum Scalar i40 and Scalar i80 Maintenance Guide 181

Page 208: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing Library Information

Viewing Library Information

The About screen gives you a quick glance at the following library settings:

• Library type (Scalar i40 or Scalar i80)

• Library serial number

• Copyright date

• Library firmware version

Web Client

Select Reports > About > Scalar i40/i80.

Viewing System Information

The System Information report contains information about the library.

On the operator panel, the report provides:

• Physical library information — serial number, system control board (SCB) revision, firmware version, board support package (BSP) version, date and time of last firmware update

• Tape drives — online/offline mode, firmware version, model, physical serial number, logical serial number

• Robot firmware versions — XY control, picker, camera

On the Web client, the report provides:

• Date & Time — Current date, time, and time zone settings.

• Physical Library — Host name, IPv4 address, serial number, firmware version of the physical library, IPv6 addresses if IPv6 support is enabled, board support package (BSP) level, and the date the firmware was last updated.

182 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 209: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Location of the Robot

• Encryption (this section displays only if encryption key management is licensed and configured on the library) — Key server type; encryption software version; SSL connection (enabled/disabled); primary host (primary key server IP address or host name), primary key server port number; primary key server serial number; secondary host (secondary key server IP address or host name); secondary key server port number; secondary key server serial number.

• Library Partitions — Name, serial number, control path, online/offline status, encryption method, encryption type, number of storage slots, number of media, and number of tape drives configured for each partition.

• Drives — Location coordinates, vendor, model, type, serial number, physical serial number (P-SN), logical serial number (L-SN), encryption method, and firmware level.

Operator Panel

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Reports > About Library.

2 Press Next to scroll through all the screens. Press Exit to exit at any time.

Web Client

Select Reports > System Information.

Viewing the Location of the Robot

You can set the operator panel to view the robot position as library operations are performed. This view is helpful in diagnosing any library problems because you can see where the robot is, whether it contains a tape, and the finger position.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 183

Page 210: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Location of the Robot

If you perform an operation from the remote interface, the operator panel displays the operation as it is performed. If you perform an operation from the operator panel, once complete, you can return to the Robot View to view the completed operation status.

Note: The operator panel does not update the left side graphical display until the motion is complete (success or failed)

On the operator panel, do the following:

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Tools > Robotic View.

The left graphical section depicts the top-down current location of the robot on the X axis.

• The numbers indicate the storage column.

• The 'D' designates the tape drive column.

184 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 211: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Location of the Robot

• The triangle represents the robot. If it is filled in, then the robot contains the media, otherwise the robot is empty. The direction the triangle points to indicates its location.

The right information section provides the following:

• Describes the current or last operation performed. If the operation performed affects a device location, the description will be numeric—for example Move Media: [1,2,5] to [1,5,1]. If the operation affects a slot location, such as unlocking a magazine, the description will be textual —for example, Unlock: Left Magazine.

• Provides the status of the operation—Active, Completed, or Failed.

2 For additional information about the status, select Details.

This screen provides details for the library status:

• Last Operation - Status of last completed operation—Succeeded or Failed.

• Robot - The robot location refers to where the robot was at the end of the operation. For example, if the robot is between two slots, it will display the robot location as “Robot: At [0,1,4] - [0,1,5]”. If it is directly in front of a slot, it would then read, for example “At [0,4,4]”.

• Picker - Extended or Retracted.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 185

Page 212: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Library Configuration Report

• Picker Fingers - Engaged or Released.

3 Select Exit to return to the Robot View.

Viewing the Library Configuration Report

The Library Configuration Report is a dynamic representation of the various library resources, including tape drives, slots, partitions, and library chassis. The report shows which slots are assigned to partitions, I/E stations, configured as cleaning slots, or unassigned; whether the slot contains a tape drive; and whether a tape drive is the control path for its partition. You can view all slot location coordinates or media barcodes at the click of a button, and get detailed information about a specific resource by clicking on it.

You can view the report on the Web client.

Web Client

1 Select Reports > Library Configuration. The Library Configuration Report displays in a new window.

2 Do any of the following:

• In the Legend, click a partition name to view information about the partition.

Note: Each partition is assigned a number and color. All slots and tape drives that are assigned to a partition are represented in the library map by the partition number and color.

• In the library map, click a specific slot to view information about the slot.

• In the library map, click a specific tape drive to view information about the tape drive.

• In the library map, click the chassis number (0) below the tape drives to view information about the chassis.

186 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 213: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Library Configuration Report

• Click Show Barcodes to display the barcodes for all imported cartridges.

• By default, the Library Configuration Report displays the coordinates for all licensed slots that are assigned to a partition. To view all library slot coordinates, click Show ALL coordinates.

• To print the report, click the Print icon in the upper right of the screen.

Clicking on a resource (tape drive, slot, partition, or chassis) brings up a detailed window containing the following information:

• Tape Drives — The following information is provided for each installed tape drive:

• Fibre Channel tape drive — interface type, tape drive type, state (ready/not ready), status (online/offline), assigned partition name, location coordinates, media barcode (if media is in slot; “No_Label” means unreadable barcode), media type (if media is in the slot), element address, vendor, model, form factor (half height or full height), physical SN, logical SN, world wide node name (WWNN), world wide port name (WWPN), loop ID, requested topology, requested speed, actual topology, actual speed, maximum speed, tape drive firmware level, whether the tape drive is the control path for its partition, and encryption method.

• Serial Attached SCSI (SAS) tape drive — interface type, tape drive type, state (ready/not ready), mode (online/offline), assigned partition name, location coordinates, media barcode (if media is in slot; “No_Label” means unreadable barcode), media type (if media is in slot), element address, vendor, model, form factor (half height or full height), physical SN, logical SN, SAS Address, tape drive firmware level, whether the tape drive is the control path for its partition, and encryption method.

• Slots — The following information is provided for each slot: type, assigned partition name (storage and I/E station slots only), location coordinates, cartridge barcode (storage and I/E station slots only; “No_Label” means unreadable barcode), media type, element address, encryption method, get count, get retries, put count, and put retries. If the slot is a cleaning slot, the cleaning status (usable/expired) and cleaning count (the number of times the cartridge was used to clean a tape drive) are also displayed.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 187

Page 214: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibrarySaving and E-mailing the Library Configuration Record

• Partitions — The following information is provided for each partition: name, status (online/offline), emulation type, barcode policy, total number of tape drives, number of active tape drives, total media, mounted media, total slots, full slots, total I/E station slots, full (occupied) I/E station slots, and encryption method.

• Chassis — The following information is provided for each chassis: manufacturer, model, and serial number.

Saving and E-mailing the Library Configuration Record

The library configuration record is a text file that contains details about the library’s configuration. The configuration record can be saved or e-mailed to a specified e-mail address.Information in the library. The configuration record includes:

• Product information — Vendor, model, product ID, product version (library firmware version), and serial number

• License information — License keys installed and descriptions, installation date, and expiration date

• Primary Network Information —Host Name, DHCP enabled/disabled, IP address, netmask, gateway, Ethernet MAC, Ethernet link speed (Mbits/s), and Ethernet link present

• Chassis information — Manufacturer, model, serial number, and location

• Tape drive information:

• Fibre Channel (FC) tape drives — Partition name, number of tape drives in partition, drive location, SCSI element address, online status, active status, ready state, vendor, model, form factor, serial number, firmware version, drive type, logical serial number, interface type, World Wide (WWN), loop ID, topology, actual topology, speed, and actual speed

188 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 215: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibrarySaving and E-mailing the Library Configuration Record

• Serial Attached SCSI (SAS) tape drives — partition name, number of tape drives in partition, drive location, SCSI element address, interface type, drive type, ready state, online status, barcode, media type, element address, vendor, model, physical serial number, logical serial number, SAS Address, firmware level, control path status

Note: The library configuration report lists the native device identifier as reported by the tape drive. HP tape drives always report SCSI as the native device identifier, even if they are Fibre Channel or SAS. For example, if you have HP L TO-4 Fibre Channel or SAS drives, they will be listed in the report as HP LTO-4 SCSI drives.

• Partition information:

• Library information — Number of partitions, number of cleaning slots, number of unassigned slots, number of import/export (I/E) slots, I/E manual assignment setting

• Partition details — Partition name, number of slots, number of tape drives, and number of cartridges

Saving the Configuration Record

Administrators can use the Tools - Save Configuration Record screen on the Web client to e-mail the library configuration record.

You can only save the library configuration record from the Web client.

Web Client

1 Select Tools > Save Configuration Record.

2 Save the file to a known location on your computer.

E-mailing the Configuration Record

Administrators can use the Tools - E-mail Configuration Record screen on the Web client to e-mail the library configuration record.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 189

Page 216: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Network Settings Report

Note: Do not enter more than one e-mail address in the E-mail Address text box on the Tools - E-mail Configuration Record screen. If you need to send the configuration record to multiple e-mail addresses, repeat the procedure for each e-mail address.

Before you can e-mail the configuration record, the library e-mail account must be configured. For information on setting up the e-mail account, see Receiving Customer Library E-mail on page 2; for more details, see the user’s guide.

You can only e-mail the library configuration record from the Web client.

Web Client

1 Select Tools > E-mail Configuration Record.

2 Type an e-mail address into the E-mail Address text box.

3 Click Apply.

Viewing the Network Settings Report

The Network Settings report provides information on the following library settings:

• Network — Host name, primary DNS, and alternate DNS

• IPv4 Settings — DHCP enabled/disabled, IP address, gateway, and netmask

• IPv6 Settings (if IPv6 is enabled) — DHCP enabled/disabled, stateless configuration enabled/disabled, static configuration enabled/disabled, net prefix, gateway, and all IPv6 addresses

• SSL — SSL, port, and cipher

• SMI-S — Access (enabled/disabled) and state (enabled/disabled)

• SNMP — Enabled/disabled status for Access, V1, V2, V3, and encryption; algorithm; and port

• SNMP-Traps — IP addresses and ports

190 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 217: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the Logged in Users Report

Web Client

Select Reports > Network Settings.

Viewing the Logged in Users Report

The Logged In Users report contains information about the users that are currently logged in to the library.

The report contains the following information about each user:

• User Name — User name of logged in user

• Privilege — Privilege level of the logged in user (Admin for administrator, User for user)

• Login Date/Time — Date and time the user logged into the library

• Last Activity Date/Time — Date and time when the user last logged into the library

• Login Location — IP address or host name of the system used to access the library

• User Interface — User interface used to access the system (Web Client or Operator Panel)

Web Client

Select Reports > Logged in Users. The report displays in a new window.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 191

Page 218: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing the All Slots Report

Viewing the All Slots Report

The All Slots report contains information on all storage, import/export (I/E) station, and tape drive slots that are currently assigned to one or more partitions.

The report contains the following information about each slot:

• Slot Type — I/E station, storage, cleaning, or tape drive slot.

• Barcode — Barcode number of the cartridge installed in the slot. No barcode number means the slot is empty. “No_Label” means the barcode is unreadable.

• Partition — Partition that owns the slot (I/E station slots are shared by all partitions).

• Location — Location coordinates of the slot.

• Element Address — Element address of the slot.

• Encryption — The encryption state of the media in the slot. In order for the library to know the encryption state, the tape must have been placed into an encryption-capable tape drive in the library. The encryption-capable tape drive reads and records the encryption state of the tape, and the encryption state displays as “Encrypted” or “Not Encrypted.” If the tape was not placed into an encryption-capable tape drive in the library, or if the slot is empty, the encryption state displays as “Unknown.”

• Get Count — The number of times the picker successfully removed a tape from the slot.

• Get Retries — The number of times the picker had to perform a recovery operation to remove a tape from the slot.

• Put Count — The number of times the picker successfully placed a tape into the slot.

• Put Retries — The number of times the picker had to perform a recovery operation to place a tape into the slot.

Web Client

Select Reports > All Slots.

192 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 219: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing, Saving, and E-mailing Library Logs

Viewing, Saving, and E-mailing Library Logs

You can view, save, and e-mail several logs containing information about the library:

• Cleaning Log

• Diagnostic Tickets Log

• SKM Encryption Key Import Warning Log

• Tape Drive Log

Cleaning Log The Cleaning Log shows all cleanings that have been performed in the library. When the log reaches its maximum size, the oldest information is replaced as new information is added.

The log provides the following information: Date Time (date and time); Barcode (barcode of the cleaning cartridge); Tape (location coordinates of the cleaning cartridge); Drive (location coordinates of the tape drive that was cleaned); Status (pass/fail); Return Code (service use only), Cleaning Type (Manual, Auto, MoveMedium), Expired (“Invalid” if the tape is expired or a data tape was improperly used to clean; “-” if not applicable); Usage Count (“N/A” if the cleaning did not complete); Reserved.

Web Client

1 Select Reports > Log Viewer.

2 Select Cleaning Log and press Next.

3 The report displays in a new window for viewing.

4 You can save or e-mail the report following the on-screen instructions.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 193

Page 220: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing, Saving, and E-mailing Library Logs

Note: If you want to e-mail the log file to a recipient, type the recipient’s name in the text box next to the E-mail button, and then click the E-mail button. You must have your e-mail notification configured in order to e-mail a log file. See Receiving Customer Library E-mail on page 2; for more details, see the user’s guide.

Diagnostic Tickets Log The Diagnostic Tickets Log records all diagnostic tickets issued by the library.

The log provides the following information: Num (ticket number to provide a consecutive listing of tickets in the order issued; the first ticket issued is assigned number 1, the second ticket 2, and so on); State (open, unopened, closed); Priority (low, high, urgent); Created (date the ticket was first issued); Last Updated (date the ticket was last issued); Cause Code (the number assigned to the fault and which displays in the full ticket name; Description; and Details.

Web Client

1 Select Reports > Log Viewer.

2 Select Diagnostic Tickets Log and press Next.

3 The report displays in a new window for viewing.

4 You can save or e-mail the report following the on-screen instructions.

Note: If you want to e-mail the log file to a recipient, type the recipient’s name in the text box next to the E-mail button, and then click the E-mail button. You must have your e--mail account configured in order to e-mail a log file. See Receiving Customer Library E-mail on page 2; for more details, see the user’s guide.

SKM Encryption Key Import Warning Log

Lists keys that failed the most recent data key import operation. This log is only available if you are running Scalar Key Manager (SKM).

194 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 221: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing, Saving, and E-mailing Library Logs

Web Client

1 Select Reports > Log Viewer.

2 Select SKM Encryption Key Import Warning Log and press Next.

3 The report displays in a new window for viewing.

4 You can save or e-mail the report following the on-screen instructions.

Note: If you want to e-mail the log file to a recipient, type the recipient’s name in the text box next to the E-mail button, and then click the E-mail button. You must have your e-mail account configured in order to e-mail a log file. See Receiving Customer Library E-mail on page 2; for more details, see the user’s guide.

Tape Drive Log The library allows you to retrieve tape drive logs using the Web client. Tape drive log information can be used to help troubleshoot the library, the tape drive sled, and tape drive issues.

Since the log retrieval process can take up to 30 minutes, the tape drive and associated partition are automatically taken offline during the operation and brought back online when the operation completes. You will be asked to confirm that you want to take the tape drive and partition offline.

Tape drive log files adhere to the following naming convention: UDS_ID_SN.DMP, where ID identifies the tape drive coordinate location within the library and SN identifies the tape drive serial number.

Web Client

1 Select Tools > Drive Operations.

2 Select Retrieve tape drive log and click Next.

3 If your library contains multiple tape drive interface types, select the interface type of the tape drive from which you want to retrieve logs and click Next.

4 The Retrieve Drive Log screen displays. This screen lists the available tape drives.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 195

Page 222: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing, Saving, and E-mailing Library Logs

5 Select a tape drive from which you want to retrieve logs and click Next.

Note: If there is more than one page of tape drives, use the Page 1 of x arrows to view the additional tape drives.

Note: Bold column headings in the table can be sorted. For example, selecting the Location column heading will sort by location coordinates.

6 Click Apply.

A dialog displays asking you to confirm you want to take the partition offline.

7 Click OK.

The Progress Window displays, displaying information on the action, elapsed time, and status of the operation.

8 If the Progress Window displays a “completed” message, you can close the window and save the file to your computer.

9 If the screen displays a “failure” message, the tape drive log was not successfully retrieved. Follow the instructions listed in the Progress Window to resolve any issues that occurred during the operation. If a complete tape drive log could not be retrieved, you may still be able to access a partial log. If so, a note will appear stating, “A complete tape drive log could not be retrieved, but a partial log is available and may be saved for further analysis once the progress window is closed.”

196 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 223: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing Library Information on the Operator Panel

Viewing Library Information on the Operator Panel

The operator panel provides several brief reports about the library.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

Viewing Partition Information

The operator panel provides an overview of partition information. For each partition, you can see the following information:

• Online/offline mode

• Control path tape drive location coordinates

• Number of tape drives

• Number of storage slots

• Number of I/E station slots containing a tape cartridge assigned to the partition

Operator Panel

1 Select Reports > Partitions.

2 If the library contains more than one partition, use the Up and Down buttons to select a partition and press Select.

Viewing Tape Drive Information

The operator panel provides an overview of tape drive information. For each installed tape drive, you can see the following information:

• Online/offline mode

• Partition to which the tape drive is assigned

• Whether the tape drive is the control path for the partition

• State (ready/active/mounted)

• WWNN (if Fibre Channel) or SAS address (if SAS)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 197

Page 224: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryViewing Library Information on the Operator Panel

Operator Panel

1 Select Reports > Tape Drives.

2 If the library contains more than one tape drive, use the Up and Down buttons to select a tape drive and press Select.

Viewing Network Settings

A short report on the operator panel displays the library’s network settings: host name, IP address, and network configuration.

Operator Panel

1 Select Reports > Network Settings.

2 If IPv6 is enabled, the IPv4 information is shown on the first screen. Press Next to see the IPv6 address information on the next two or more screens. Although the library can have unlimited IPv6 address, a maximum of three are shown in this report.

Viewing the Date, Time, and Time Zone

The operator panel displays the current date, time and time zone configured on the library.

Operator Panel

Select Reports > Date/Time.

Viewing Licenses The operator panel displays a list of all the licenses currently installed on the library: number of COD slots licensed, number of unlicensed slots, and whether Advanced Reporting is licensed.

Operator Panel

Select Reports > Licenses.

198 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 225: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryUsing Advanced Reporting

Using Advanced Reporting

The Advanced Reporting feature is only available to customers if they have Advanced Reporting licensed on the library, but it is always available to service users.

The Advanced Reporting license provides the following library features:

Control Path Failover (CPF) - Provides support for configuring the HP LTO-5 drive for control path failover. When control path failover is used, one drive is assigned as the primary control path and another drive as the control path failover (secondary) drive. The control path failover drive is used whenever the primary control path drive fails or is inoperable.

Note: For more information about CPF, refer to Using Advanced Reporting Control Path Failover and Forced CPF on page 38.

Reports - Listed below are report names. You can view, configure, send via e-mail, and save and reuse report configurations as templates. In addition, you can automatically e-mail any of the reports to designated recipients at specified, scheduled times.

• Drive Resource Utilization Report - Provides tape drive usage information, showing you which tape drives are working at optimum capacity and which are under-utilized. This report can help you allocate your tape drive resources properly.

• Media Integrity Analysis Report - Provides TapeAlert count for various combinations of tape drives, tape cartridges, and TapeAlert flags. This report can help you determine if a problem is due to a specific tape drive or tape cartridge.

Logs - Listed below are available logs:

• Media Security Log - Lists media that has been removed from the library.

• Media Usage Log - Lists media usage information regarding capacity, and read and write errors for media ever mounted in a drive.

For complete information and instructions on using Advanced Reporting, see the user’s guide or the Web client online help.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 199

Page 226: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 5: Getting Information About the LibraryUsing Advanced Reporting

200 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 227: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6Troubleshooting and

Diagnostics

The Scalar i40 and Scalar i80 libraries include advanced system monitoring and alerting mechanisms that inform you of library status and issues. The library provides you with status information about various library subsystems and components. It also notifies you of issues it detects and guides you through diagnosing and correcting issues before problems interfere with backups.

This chapter covers:

• Capturing Snapshots of Library Information

• Troubleshooting Library “Not Ready” Messages

• Retrieving Tape Drive Logs

• Interpreting LEDs

• Running the Installation and Verification Test (IVT)

• Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests

• Running the Random Move Test

• Performing Library Diagnostics Tests

• Resetting Factory Defaults

• EKM Path Diagnostics

• Troubleshooting Diagnostic Ticket Display Issue

Quantum Scalar i40 and Scalar i80 Maintenance Guide 201

Page 228: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsCapturing Snapshots of Library Information

Capturing Snapshots of Library Information

You may have asked the customer to capture a snapshot of the library so they can better diagnose issues. The Capture Snapshot operation captures detailed information about the entire library in a single ASCII file that can be e-mailed to technical support personnel.

The logged information consists of configuration data, status information, and trace logs for library components. Trace logs collect problem data and provide support personnel with vital library information for troubleshooting and solving problems.

You can e-mail the snapshot file from the Web client. You can also download the Capture Snapshot file to a computer, however, you cannot print Capture Snapshot files directly from the Web client.

Depending on the library configuration and the user’s connection speed, saving the snapshot file takes approximately 30 minutes. The resulting file size can be large. A customer’s firewall file-size limitations could prohibit them from e-mailing the file.

On the Web client, you must ensure that the library e-mail account is appropriately configured before attempting to e-mail the snapshot from the library. If the library e-mail account address is not configured, an error appears. For a brief discussion on configuring the library e-mail account, see Receiving Customer Library E-mail on page 2; for more details, see the user’s guide.

You can set up the library to automatically capture and attach a snapshot to specific diagnostic ticket e-mail notifications. If the library is in the process of capturing an automatic snapshot, you will not be able to manually capture a snapshot via the Web client until the automatic snapshot is complete. If this happens, an error message will display. Wait about 10 minutes and try again.

You can only capture a snapshot via the Web client.

Web Client

1 Select Tools > Capture Snapshot.

2 Select whether to download the file or e-mail it to a recipient, and click Apply.

202 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 229: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsTroubleshooting Library “Not Ready” Messages

Troubleshooting Library “Not Ready” Messages

Library “not ready” messages can occur on the operator panel and the Web client.

“Not Ready” Messages on the Operator Panel

If a customer gets a “not ready” message on the operator panel at startup, it means the robot cannot move.

If the “not ready” message occurs upon initial installation (first time out of the box or after a chassis replacement), make sure the customer has removed the Y-tray restraint and properly released the robot (see Removing the Y-tray Restraint and Releasing the Y-tray at Initial Install on page 35).

If the robot has been properly released, or this has happened at a time other than initial startup, check for diagnostic tickets and follow their resolutions. You can also power cycle the library to try to clear the error.

“Not Ready” Messages on the Web Client

The Web client user interface includes a header that contains the company logo, product name, and the three main navigation buttons (Home, Help, and Logout). In addition, a message in the header alerts you when the library is not ready. (No message displays in the header when the library is in a ready state.)

“Library not ready” messages continue to display in the header until the issue has been resolved, and the robot has completed its calibration.

If the library displays a “not ready” message, you may be able to tell from the message how to remedy the situation. If not, the library generates a diagnostic ticket whenever the library enters a “not ready” state. The diagnostic ticket may provide information that can help you troubleshoot the problem. For more information, see Chapter 7, Diagnostic Tickets and Resolutions.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 203

Page 230: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsTroubleshooting Library “Not Ready” Messages

The library “not ready” messages include the following, with possible solutions listed:

Note: You may not see the “not ready” message in the Web client until the browser refreshes. Similarly, even if the problem has been resolved, the “not ready” message will not disappear from the Web client until the browser refreshes.

Message Resolution

Library is not ready The library is initializing and becoming ready. Wait for the library to finish initialization.

Library is becoming ready Wait for the library to finish initialization.

Library is not initialized Most likely a problem with the robot. Try the following: • Check the diagnostic ticket and

follow the resolution steps listed (see Chapter 7, Diagnostic Tickets and Resolutions).

• Power cycle the library to clear the error. If that fails, contact Quantum Support.

Library needs manual attention

Most likely a problem with the robot or other component. Try the following: • Check the diagnostic ticket and

follow the resolution steps listed (see Chapter 7, Diagnostic Tickets and Resolutions).

• Power cycle the library to clear the error. If that fails, contact Quantum Support.

204 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 231: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsRetrieving Tape Drive Logs

Retrieving Tape Drive Logs

The library allows you to retrieve tape drive logs using the Web client. Tape drive log information can be used to help troubleshoot the library, the tape drive sled, and tape drive issues.

Since the log retrieval process can take up to 30 minutes, the tape drive and associated partition are automatically taken offline during the operation and brought back online when the operation completes. You will be asked to confirm that you want to take the tape drive and partition offline.

Tape drive log files adhere to the following naming convention: UDS_ID_SN.DMP, where ID identifies the tape drive coordinate location within the library and SN identifies the tape drive serial number.

You can only retrieve tape drive logs via the Web client.

Web Client

1 Select Tools > Drive Operations.

2 Select Retrieve Tape Drive Log.

3 Click Apply.

4 When the Success message appears, complete the next screens to save the log file to your computer.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 205

Page 232: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsInterpreting LEDs

Interpreting LEDs

LEDs provide a visual indication about the status of certain library components. LEDs can sometimes communicate that a problem exists when diagnostic tickets cannot.

The following components of the library have LEDs:

• Front panel

• System control board (SCB)

• Tape drives

• Power supplies

Front Panel LEDs There are two LEDs on the front panel, above the power button. They function as follows:

Figure 87 Front Panel LEDs

LED Location Color Indicates

Power-on LED (closest to power button)

Green Library power is ON.

Ticket indicator LED. (farthest from power button)

Amber The LED is illuminated when at least one open or unopened diagnostic ticket exists.

Ticket indicator LED

Power-on LED

206 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 233: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsInterpreting LEDs

System Control Board LEDs

The SCB has one health status LED. In addition, each Ethernet port contains two LEDs, a green “activity indicator” and an amber “link indicator.” The Ethernet port closest to the center of the library is for customer use. The Ethernet port farthest from the center of the library is for service use only.

Figure 88 System Control Board LEDs

LED Color Indicates

SCB Health Status LED

Green Healthy and operational.

Red Failure. Replacement required.

Ethernet Port Green LED (Activity Indicator)

Green This LED illuminates when actual “traffic” is being sent over the Ethernet cable. The LED may be blinking or on solid; it blinks more rapidly the more traffic is being sent over the connection. When the LED is lit, communications are in process and when the LED is off no communication is occurring.

Ethernet Port Amber LED (Link Indicator)

Amber This LED illuminates solidly when a “link” is established, and will be off when no “link” is present. “Link” means an Ethernet cable is connected and the other end of the cable is also connected to another powered-up and operational Ethernet device.

Health status LEDCustomer Ethernet port LEDs

Service Ethernet port LEDs

Quantum Scalar i40 and Scalar i80 Maintenance Guide 207

Page 234: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsInterpreting LEDs

Tape Drive/Sled LEDs The library supports SAS and Fibre Channel tape drives. The drive sled LEDs for each are described below.

SAS

SAS Tape Drive Sleds have one LED that indicates the following:

Fibre Channel

Fibre Channel tape drive sleds have two LEDs on their rear panel, indicated on the drive sled as STATUS and LINK (see Figure 89).

Color Indicates

Green Healthy and operational.

Amber Tape drive is offline.

Red Failure. Replacement required.

LED Color Indicates

Status Green Healthy and operational.

Amber Tape drive is offline.

Red Failure. Replacement required.

Link Green On solid — Fibre Channel link is presentFlashing — Fibre Channel link is present and communications are in process

Off No Fibre Channel link is currently present.

208 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 235: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsInterpreting LEDs

Figure 89 Fibre Channel Tape Drive LEDs

Half-height FC tape

drive

Full-height FC tape

drive

Link LED

Link LED Status LED

Status LED

Quantum Scalar i40 and Scalar i80 Maintenance Guide 209

Page 236: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsInterpreting LEDs

Power Supply LED Diagnostic tickets typically report all problems related to power supplies. You can also observe the power supply LED to see if the power supply is functioning appropriately (see Figure 90). The power supply LED indicates the following:

Figure 90 Power Supply LED

LED Color Indicates

Green AC power is present and the library front panel power switch is turned ON.

Amber AC power is present but the library front panel switch is turned OFF.

Red Power supply failure.

Off No power. Ensure the power supply is correctly plugged into a wall outlet.

Power supply LED

210 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 237: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsRunning the Installation and Verification Test (IVT)

Running the Installation and Verification Test (IVT)

The Installation and Verification Test (IVT) is used to evaluate a newly installed library. Its purpose is to verify that the robot is functioning properly, and that the magazines and tape drives are installed correctly and reachable by the robot. It also verifies that barcode labels can be read by the robot scanning operation.

Important: You should run the full IVT upon installation of a new library, and at any other time you remove, replace, or service components that require you to move the library into or out of a rack or desktop kit. You must run the robotics test after a robot replacement.

The full IVT consists of three subtests. You may run the sub-tests separately (see Performing Library Diagnostics Tests on page 216). The full IVT may take up to 30 minutes to complete.

• Robotics Test — A series of tests that evaluate the basic functionality of the robotics assembly, including picker travel, Y-carriage assembly travel, barcode scanning, calibration sensors, and several moves of a scratch tape. It also calibrates the robot to the library. The test takes up to 11 minutes to complete.

• Tape Drive Test — For each installed tape drive, the robot moves a scratch tape into the tape drive, inventories the scratch tape, and moves the scratch tape out of the tape drive. The test takes 1–2 minutes per tape drive.

• Magazine Test — Moves a scratch tape through all storage slots in the library. These tests verify the robotics can reach all the slots in the magazine for both get and put operations. The test takes up to 5 minutes per magazine.

Details about running the IVT include:

• Running the IVT takes partitions offline and logs all users off of the Web client.

• The operator panel displays progress of all three subtests. Before a test begins, its progress is “Scheduled.” When a test begins, its progress changes to “Running.” Once a test completes, its progress changes to either “Passed” or “Failed.”

Quantum Scalar i40 and Scalar i80 Maintenance Guide 211

Page 238: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsRunning the Installation and Verification Test (IVT)

• You can stop the IVT by pressing the Stop button. The progress of the currently running test changes to “Stopping.” Once stopped, the current test and all other scheduled tests display “Stopped.”

• You can only perform the IVT from the operator panel.

Prerequisites for Running IVT

Certain prerequisites must be met in order to run the IVT. Prior to running the IVT, the library checks to make sure all the prerequisites are met. If any is not, the operator panel displays a message telling you how to resolve the issue. Prerequisites include:

• All diagnostic tickets must be closed.

• I/E station slots must be allocated (minimum of five).

• All magazines must be installed in the library (two in the Scalar i40; four in the Scalar i80).

• At least one tape drive must be installed in the library.

• All installed tape drives must be in the ready state. (You can check the Web client Setup > Drive Settings for listing of which drives are in the ready state.)

• A scratch tape must be in the top I/E station slot. The scratch tape must be assigned to the System partition. The scratch tape must be compatible with all unloaded tape drives installed in the library. For a list of supported media, see the user’s guide.

Operator Panel

1 Make sure the prerequisites listed in Prerequisites for Running IVT on page 212 are met.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

2 Select Tools > IVT.

A message displays, telling you that partitions will be turned offline and all Web client users will be logged out.

212 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 239: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsRunning the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests

3 Press Yes to set partitions offline, log users off the Web client, and continue with the test.

The library conducts a series of prerequisite checks to be sure everything is in order. Each prerequisite is listed as the library checks it. If something is not set up correctly to run the IVT, the operator panel displays a message letting you know how to fix it. Once you fix the issue, again select Tools > IVT. If all is in order, the test begins.

4 When the test completes, if any of the three subtests fails, check the library diagnostic tickets to help determine and resolve the problem.

Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests

If you do not need to run the full IVT, you can run the robotics, tape drive, or magazine test separately to check an individual component. You should do this when you remove, replace, or service a component that does not require you to remove the library into or out of a rack or desktop kit.

Details about running the diagnostic subtests is the same as for the full IVT (see Running the Installation and Verification Test (IVT) on page 211).

Details about running the diagnostic subtests include:

• Running a diagnostic takes partitions offline and logs all users off of the Web client.

• The operator panel displays progress of the diagnostic. When a test begins, its progress displays as “Running.” Once a test completes, its progress changes to either “Passed” or “Failed.”

• Once a diagnostic test starts, you cannot stop it. You must let it run to completion.

• For the tape drive and magazine diagnostics, you may choose just one device to test, or you can choose to test all. The magazine diagnostic tests all the slots in the selected magazine(s).

• You can only perform the subtests from the operator panel.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 213

Page 240: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsRunning the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests

Prerequisites for Running Diagnostic Subtests

Certain prerequisites must be met in order to run the diagnostics. Prior to running a diagnostic, the library checks to make sure all the prerequisites are met. If any is not, the operator panel displays a message telling you how to resolve the issue. Prerequisites include:

• All diagnostic tickets must be closed.

• I/E station slots must be allocated (minimum of five).

• All magazines must be installed in the library (two in the Scalar i40; four in the Scalar i80).

• A scratch tape must be in the top I/E station slot. The scratch tape must be assigned to the System partition. The scratch tape must be compatible with all unloaded tape drives installed in the library. For a list of supported media, see the user’s guide.

• For the tape drive diagnostics only, at least one tape drive must be installed in the library. All installed tape drives must be in the ready state. (You can check the Web client Setup > Drive Settings for listing of which drives are in the ready state.)

Operator Panel

1 Make sure the prerequisites listed in Prerequisites for Running Diagnostic Subtests on page 214 are met.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

2 Select Tools > Diagnostics.

3 Select Robotics Test, Tape Drive Test, or Magazine Test and press Select.

4 For the tape drive or magazine test, select which tape drive or magazine you want to test, or select ALL, then press Select.

214 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 241: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsRunning the Random Move Test

5 Press Yes to set partitions offline, log users off the Web client, and continue with the test.

The library conducts a series of prerequisite checks to be sure everything is in order. Each prerequisite is listed as the library checks it. If something is not set up correctly, the operator panel displays a message letting you know how to fix it. Once you fix the issue, start over from Step 1. If all is in order, the test begins.

6 Once complete, if the test fails, check the library diagnostic tickets to help determine and resolve the problem.

Running the Random Move Test

This will perform a demo that consists of moving a scratch tape into random slots around the library. Partitions are set offline and the test runs continuously until you stop it. You can only run this test from the operator panel.

Operator Panel

1 Install a scratch tape in the top I/E station slot.

2 Assign the scratch tape to the System partition.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

3 Select Tools > Random Move Test.

4 Press Run.

5 Press Yes to set partitions offline, log users off the Web client, and continue with the test.

6 When you are ready to stop the test, press Stop.

7 When the operator panel displays the message that the test has stopped, press OK.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 215

Page 242: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsPerforming Library Diagnostics Tests

Performing Library Diagnostics Tests

The following diagnostics tests are available:

• Resetting a Tape Drive

• Robotics Get/Put Test

Note: The Diagnostics menu is only available under the Admin login. Use the information about Diagnostics to understand or help a customer through these tests. If you are logged in as Service, you can perform these tests directly without entering the Diagnostics menu (the Diagnostics menu is not available under the Service login).

Entering the Diagnostics Menu

The Diagnostics menu on the Web client contains tests you can run to determine if tape drives and robotics are working as they should.

Notes about Diagnostics include:

• Only users with Admin level privileges can access Diagnostics. You need to be logged in with Admin privileges to enter Diagnostics. If you are logged in as Service, go directly to the test sections below.

• Entering Diagnostics takes all your library partitions offline. Be sure any crucial operations have stopped before you enter Diagnostics. When you exit Diagnostics, your partitions return to the online/offline status they were in previously.

• Only one user can be logged into Diagnostics at a time. Entering Diagnostics disconnects all other Web client users with the same or lower privileges (the operator panel user is not logged out, but any attempted operation using partitions will fail). Users will be unable to log in to the Web client and will get an error message stating that Diagnostics is in progress.

• You can only enter Diagnostics from the Web client.

216 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 243: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsPerforming Library Diagnostics Tests

Web Client - Logged in as Admin

If you are logged in as Service, go directly to Resetting a Tape Drive on page 217 or Robotics Get/Put Test on page 218.

1 Select Tools > Diagnostics.

A confirmation dialog appears, alerting you that all other users will be logged out and library partitions will be taken offline.

2 Click OK.

You are now in a page that looks much like the regular Home page, but with different choices in the menu bars. Also, you will notice that all your partitions are offline.

3 Select the test you want to run from the menus. Your choices include:

• Tape Drive Reset (see Resetting a Tape Drive on page 217 for more information)

• Robotics Get/Put Test (see Robotics Get/Put Test on page 218 for more information)

4 To exit Diagnostics, select Exit.

Resetting a Tape Drive The Drive Reset operation power cycles the tape drive while the tape drive remains in the drive sled in the library. You may want to perform a reset if a tape drive does not come ready or it is not behaving properly (for example, if a tape is stuck in the drive and will not unload).

The reset may take several minutes. After the reset operation completes, the tape drive is rebooted and reconfigured. This takes about 60 seconds. Wait 60 seconds before performing further drive operations.

You may perform a tape drive reset from either the operator panel or the Web client. If you use the Web client, Service users can perform this test directly from the service menu. Admin users must enter Diagnostics, which logs out all users of the same or lower privilege level (see Performing Library Diagnostics Tests on page 216).

Quantum Scalar i40 and Scalar i80 Maintenance Guide 217

Page 244: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsPerforming Library Diagnostics Tests

Operator Panel

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Actions > Tape Drive > Reset.

2 Select the tape drive you want to reset and push Reset.

Once the operation completes, the operator panel displays a message stating that the operation completed, and there will be diagnostic tickets if it failed.

3 Press OK.

4 Check to see if the library generated diagnostic tickets.

Web Client

1 Skip this step if you are logged in as Service and go to Step 2. Enter Diagnostics (Tools > Diagnostics, then click OK to take partitions offline and log out all other users of the same or lower privileges).

2 Select Drives > Drive Tests > Drive Reset.

3 If the tape drives are assigned to more than one partition, select the partition in which the tape drive(s) you want to reset are located. Select Unassigned if the tape drive(s) you want to reset are not assigned to a partition. Click Next.

4 Select the tape drive(s) you want to reset.

5 Click Apply.

The test runs. When complete, a “success” or “failure” message appears.

Robotics Get/Put Test The Get/Put Test requires the robot to remove one tape cartridge from the top I/E station slot, and then put the tape cartridge back into the same slot. To run this test, you must insert a tape into the library’s top (uppermost) I/E station slot.

Service users can perform this test directly from the service menu. Admin users can only perform this test from the Web client, by entering Diagnostics (see Performing Library Diagnostics Tests on page 216).

218 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 245: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsResetting Factory Defaults

Web Client

1 Install a scratch tape in the top I/E station slot.

2 If manual cartridge assignment is enabled, assign the scratch tape to the System partition.

3 Skip this step if you are logged in as Service and go to Step 4. Enter Diagnostics (Tools > Diagnostics, then click OK to take partitions offline and log out all other users of the same or lower privileges).

4 Select Robotics > Robotics Get/Put Test.

5 Click Apply.

6 The test runs. When complete, a “success” or “failure” message appears.

Resetting Factory Defaults

Resetting factory defaults restores the library’s default configuration.

Resetting factory defaults clears:

• Most of the library’s configurable items, such as partitions, user accounts, import/export (I/E) station slots, cleaning slots.

• All diagnostic tickets and log information.

• Any tape drive firmware images uploaded manually.

Resetting factory defaults does NOT clear:

• Date and time, network configuration, or license key settings, nor does it change the library firmware version.

You may want to reset factory defaults if you are completely reinstalling or reconfiguring the library.

If you downgrade from your library’s firmware version to an earlier released version, library configuration settings will be reset to the factory defaults for the newly installed firmware.

If you upgrade firmware, your library configuration settings remain as you have set them.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 219

Page 246: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsEKM Path Diagnostics

Web Client

On the Web client, this feature is only available to service users using the service login and password.

1 Select Tools > Reset Factory Defaults.

A message appears stating that configuration data will be cleared and library rebooted.

2 Click Apply.

Operator Panel

On the operator panel, if logins are disabled (default), this operation is available to all users. If logins are enabled, this operation is only available to service users using the service login and password.

Note: If you are viewing the alternate home screen, select Menu to return to default home screen.

1 Select Tools > Reset Factory Defaults.

A message appears stating that configuration data will be cleared and library rebooted.

2 Press Yes to continue.

EKM Path Diagnostics

The EKM Path Diagnostics consists of a series of short tests to validate whether the key servers are running, connected, and able to serve keys as required.

220 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 247: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsEKM Path Diagnostics

There are two ways to run EKM Path Diagnostics:

• Manually — Run the Manual EKM Path Diagnostics any time you change the key server settings or library encryption settings. See Running Manual EKM Path Diagnostics on page 222 for details.

• Automatically — This feature runs automatically in the background and generates diagnostic tickets if there are problems. You can turn this feature off but it is recommended that you leave it on. See If Failure appears in the Progress Window, the diagnostics were not able to be performed. Enabling Automatic EKM Path Diagnostics on page 222 for details.

Description The EKM Path Diagnostics consists of the following tests:

• Ping — Verifies the Ethernet communication link between the library and the key servers.

• Path — Verifies that EKM services are running on the key servers.

• Config — Verifies that the key servers are capable of serving encryption keys.

Failure Scenarios If any of the tests fail, try the following resolutions and run the test again to make sure it passes:

• Ping Test Failure — Verify that the key server host is running and accessible from the network to which the library is connected.

• Path Test Failure — Verify that the key server is actually running and that the IP address configured on the library is correct. Check to see if there is a network configuration issue, such as a firewall, preventing communication with the server.

• Config Test Failure — A database inconsistency has been detected. Contact Quantum Support.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 221

Page 248: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsEKM Path Diagnostics

Running Manual EKM Path Diagnostics

1 Access the EKM Path Diagnostics screen in one of two ways:

• Select Setup > Encryption > System Configuration or Setup > Encryption > Partition Configuration and click the link that says “Click here to run EKM Path Diagnostics.”

• Enter library Diagnostics (from the Web client select Tools > Diagnostics) and then select EKM > EKM Path Diagnostics. Note that entering Diagnostics will log off all other users of the same or lower privileges and take your partitions offline. When you exit Diagnostics, the partitions automatically come back online.

2 Click Apply.

3 The library performs the diagnostics and displays pass/fail results on each of the tests in the Progress Window. This may take several minutes. If a test fails, try the solutions listed under Failure Scenarios on page 221.

4 Do one of the following:

• If Completed appears in the Progress Window, the diagnostics were performed (this does not mean that the diagnostics passed, just that the diagnostics were performed). Click Close to close the Progress Window.

If Failure appears in the Progress Window, the diagnostics were not able to be performed. Enabling Automatic EKM Path Diagnostics

You can enable the library to automatically perform EKM Path Diagnostics at selected intervals. During each interval, the library tests every configured key server. The default test interval is 10 minutes. The library generates a diagnostic ticket if there are problems.

Automatic EKM Path Diagnostics is enabled by default and should always be left enabled. You should not need to disable it unless Quantum Support directs you to do so.

For a list of tests performed, see EKM Path Diagnostics on page 220.

To enable Automatic EKM Path Diagnostics:

1 From the Web client, select Setup > Encryption > System Configuration (see Figure 91).

2 Select the Automatic EKM Path Diagnostics check box.

3 Select a test interval from the Interval drop-down list.

222 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 249: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsTroubleshooting Diagnostic Ticket Display Issue

Figure 91 Enabling Automatic EKM Path Diagnostics

Troubleshooting Diagnostic Ticket Display Issue

Optimum screen resolution for viewing using a Windows operating system is 96 DPI. If screen resolution is set higher, certain screen messages may not display as intended. For example, a line of text may have a line break in the middle of the page.

To change screen resolution, show the desktop, right click to display the Properties window, and click Settings > Advanced.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 223

Page 250: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 6: Troubleshooting and DiagnosticsTroubleshooting Diagnostic Ticket Display Issue

224 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 251: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7Diagnostic Tickets and

Resolutions

The library uses advanced problem detection, reporting, and notification technology to alert you of problems as soon as they occur. The library performs numerous self-tests to monitor the library’s operations. It performs these self-tests each time the library is powered on and during normal operation when the library is idle.

If the self-test detects a problem, the library generates a diagnostic ticket that identifies the component that is likely causing the problem. If the problem is not severe, the library continues to provide full functionality to all unaffected partitions.

When possible, the library provides instructions for resolving problems. These instructions appear on the library’s remote Web client.

Customers can frequently resolve a simple problem themselves, but if the problem is complex or involves a field replaceable unit (FRU), the customer must contact Quantum Support.

Diagnostic tickets can be e-mailed to Quantum Support for diagnosis, as can the library snapshot. For details about the snapshot, see Capturing Snapshots of Library Information on page 202.

This chapter covers:

• Ticket Priority Levels

• Viewing, Closing, and Resolving Diagnostic Tickets

• Diagnostic Ticket Error Codes

• Diagnostic Resolutions

Quantum Scalar i40 and Scalar i80 Maintenance Guide 225

Page 252: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsTicket Priority Levels

Ticket Priority Levels

There are three levels of priority: Urgent, High and Low.

• Urgent — The highest level of priority. A ticket with urgent priority indicates that a failure has occurred or a serious condition exists within the library that requires immediate corrective action. In most cases, a hardware component is no longer functioning at an acceptable level or has failed. Typical library operations required for backup or restore operations are either not possible or highly unreliable. This level of priority is conveying a critical issue.

• High — The middle level of priority. A ticket with high priority indicates that a condition exists within the library that impacts system performance, redundancy, or just a specific host application. Typical library operations can continue without immediate corrective action, although an application may have failed and may need to be restarted. A user should investigate the condition and correct the problem soon. This level of priority is conveying a warning message.

• Low — The lowest level of priority. A ticket with low priority indicates that an abnormal condition existed within the library that warrants investigation and correction but the nature of the condition may have little or no effect on operations. This level of priority is conveying an informational message.

The library has a number of visual cues to alert you that one or more diagnostic tickets exist:

• The library’s ticket indicator LED turns on to indicate that at least one ticket exists (see Front Panel LEDs on page 206).

• The operator panel displays a health status icon (see the user’s guide for description).

• The Web client displays a subsystem status icon (see the user’s guide for description).

226 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 253: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsViewing, Closing, and Resolving Diagnostic Tickets

Viewing, Closing, and Resolving Diagnostic Tickets

The initial status of all diagnostic tickets is Unopened. Once you select the Resolve button, the ticket status changes to Opened. When you close the ticket, its status changes to Closed. You can view Opened and Unopened tickets on both the operator panel and the Web client, but you can view Closed tickets only on the Web client.

You can view and close diagnostic tickets on both the operator panel and the Web client, but only the Web client provides a complete description of the event and guides you through a series of steps to resolve the issue. It is recommended that you use the Web client to view and resolve all your diagnostic tickets.

Only one person at a time can resolve a ticket. Multiple users can, however, view ticket details simultaneously.

If your Web client session goes down while resolving a diagnostic ticket, you must wait 3 minutes before you can continue resolving the diagnostic ticket.

If you do not close a diagnostic ticket and the issue recurs, the only thing that gets updated in the ticket is the date and time the issue recurred (listed under Last Occurrence on the Web client and Updated on the operator panel). Ticket details are not updated because the original issue is often the root cause. If the location of the error in the library changed since the ticket was first issued, the ticket details will continue to reflect the original error location.

Note: A diagnostic ticket can have a status of Cancelled. As discussed below in Closing Diagnostic Tickets Automatically on page 229, after a reboot or power request, the system may elect to close a ticket. This cancelled state does not indicate that a problem has been corrected. The system would re-open the ticket if the issue is encountered again.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 227

Page 254: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsViewing, Closing, and Resolving Diagnostic Tickets

Viewing Diagnostic Tickets

Operator Panel

1 Select Reports > Diagnostic Tickets.

2 Select Library, Tape Drives, or Media as the tickets you want to view. Press Select.

3 All of the relevant tickets are listed. Scroll through and select the one you want to view. Press View.

Basic details, such as ticket ID number, short description, priority, and when the ticket was created and updated, appear.

4 You can either press Close to close the ticket, or press Exit to exit without closing the ticket.

Web Client

1 You can view all diagnostic tickets by selecting Tools > All Diagnostic Tickets. Alternatively, you can view library, tape drive, and media tickets separately via the Home Page Subsystem Status buttons.

Whichever method you choose, the tickets are displayed in order of last occurrence of each event, beginning with the most recent.

Note: Last Occurrence indicates the last time a ticket event occurred. This information updates any time the event recurs. Last Occurrence does NOT update if you open, close, or resolve the diagnostic ticket. Ticket details are not updated when a ticket recurs.

2 Identify the diagnostic ticket you want to resolve.

Note: You can use the Go to Diagnostic Ticket text box at the bottom of the screen to locate a specific ticket number. In addition, if there is more than one page of tickets, use the Page 1 of x arrows to view the additional tickets.

3 To view more details about the ticket, including the location coordinates of resources that may be involved, click the Details button.

228 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 255: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsViewing, Closing, and Resolving Diagnostic Tickets

4 To resolve the ticket, click the Resolve button. A series of screens guides you through steps to resolve the issue on your own. If the situation cannot be resolved, you are instructed to contact technical support. When you have finished reading all of the Resolution screens, do one of the following:

• To close the ticket now, click Close. The Tools - All Diagnostic Tickets window displays, with the ticket no longer in the list.

• To leave the ticket open for future troubleshooting, click Exit. The ticket remains on the list.

5 You can also close all tickets at once by clicking the Close All Tickets button.

Caution: Be careful when pressing the Close All Tickets button. This closes all diagnostic tickets even if they are not resolved. It is recommended that each diagnostic ticket be viewed, analyzed, and closed individually.

Note: To display all closed tickets, select the Include Closed Tickets check box at the bottom of the screen. The Tools - All Diagnostic Tickets screen refreshes, with the Resolve button unavailable for all closed diagnostic tickets. Note that tickets that were automatically closed are designated as “Canceled.”

Closing Diagnostic Tickets Automatically

When you reboot the library, all currently open diagnostic tickets are closed automatically. If any errors occur during the reboot, the library issues new tickets.

Automatic ticket closure occurs only when you intentionally initiate a reboot, by either restarting the library, shutting down the library, or upgrading library firmware. Automatic ticket closure will not occur if the library shuts down unexpectedly or if the power cord is unplugged.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 229

Page 256: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

Disabling or Enabling this Feature

Automatic ticket closure is enabled by default. You can enable or disable this feature from the operator panel.

1 Select Setup > System Settings.

2 Press Modify.

3 Press Up to change setting as desired,

4 Press Apply.

Diagnostic Ticket Error Codes

When the library detects a problem, it generates an error code and displays it in the diagnostic ticket report. The Web client provides a full description of the problem and suggestions for resolving it.

The following tables provide details on each diagnostic ticket error code.

230 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 257: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT000

DT000 - Unmanaged System Fault

Description GUI Description: The library firmware encountered an unmanaged fault.Explanation: Library firmware has reported a problem that is not associated with a specific Diagnostic Ticket and corresponding diagnostic resolution. This problem cannot be resolved without escalation to tech support and engineering. By design, this Diagnostic Ticket should not occur. Only a code bug should result in this ticket.

Detection Scenarios • Library firmware detected an unmanaged, unexpected code path.

Root Causes • Code bug or unexpected result.

Service Resolution Steps

Perform DR000 - Contact Quantum Service on page 340.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 231

Page 258: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT001

DT001 - PS Power Loss

Description GUI Description: The library detected an AC power loss of a redundant power supply.Explanation: A power supply has detected loss of AC power. The AC power loss diagnostic ticket for a single power supply is unlikely to get posted due to the speed at which a system shut down occurs after an AC loss. This diagnostic ticket is most likely to occur when there is AC loss to a redundant power supply.

Detection Scenarios N/A.

Root Causes • AC supply is interrupted (cord removed, customer side AC failure, etc.)• Hardware failure inside supply.• Possibly removed Power Supply.

Service Resolution Steps

Perform DR001 - PS Power Loss on page 340.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Power Supply

232 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 259: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT002

DT002 - PS Failure

Description GUI Description: The library detected a power supply failure.Explanation: Power supplies report 2 failure conditions that are considered to be a hardware failure within the supply: Fan Fail, and Supply Fault. These failures can occur in both the single and redundant power supply.

Detection Scenarios • The library controller firmware received a PS interrupt, identifying the nature of the PS failure.

Root Causes • Detected PS fan failure.• Detected PS fault.• AC Power loss which is reported as a PS fault.

Service Resolution Steps

Perform DR002 - PS Failure on page 341.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Power Supply

Quantum Scalar i40 and Scalar i80 Maintenance Guide 233

Page 260: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT010

DT010 - RCS Firmware Image Error

Description GUI Description: The robotics firmware auto-leveling process cannot be performed because the necessary robotic firmware image is missing or corrupted.Explanation: The library is unable to attempt the RCS firmware auto-leveling process due to a problem with the firmware image. In this case, the auto-leveling process is not attempted and the RCS is left in the “Not Ready” state.

Detection Scenarios • A necessary auto-level file is missing in the library firmware.• A necessary auto-level file failed checksum and/or file header

validation.

Root Causes • The RCS firmware image required for RCS auto-leveling is missing.• The RCS firmware image required for RCS auto-leveling is corrupted.

Service Resolution Steps

Perform DR010 - RCS Firmware Image Error on page 342.

Possible CRUs/FRUs None

234 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 261: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT011

DT011 - RCS Auto-Level Failure

Description GUI Description: The robotics firmware auto-leveling process failed to update either the robot or imager flash image.Explanation: The normal firmware auto-level process for robotics was not successful. Each time the robot is initialized, the firmware level of the robot is checked to be consistent with the level required by the main library firmware. If the level is not correct, the robotics firmware will be up-leveled or down-leveled accordingly. Failure in this process to update to the correct robotics firmware level results in the generation of this ticket.

Detection Scenarios The Robot Controller Board could not perform one of the following operations:• Successfully receive the entire firmware image.• Validate the received flash image.• Program its flash with the XY Motion Board flash image.• Program its flash with the Picker Board flash image.• Program its imager with the Imager firmware image.

Root Causes • Communication errors between SCB and RCS.• Communication errors between the XY Motion Board and the Picker

Board.• Flash Image CRC failure on the received file.

• Hardware failures that result in unsuccessful flash programming.• FOTO FPGA failed to assert the FOTO_DONE signal after programming

and reset.

Service Resolution Steps

Perform DR011 - RCS Auto-Level Failure on page 343.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 235

Page 262: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT012

DT012 - RCS Initialization Error

Description GUI Description: The Robotic Control Subsystem did not initialize properly preventing library operations.Explanation: This ticket is designed to notify the user of a robot initialization failure. Details regarding specific initialization error reasons are conveyed in the Diagnostic Ticket details, such as servo issues, or home sensor transition, or the like.

Detection Scenarios • The RCS reported an error code when the RCS was requested to initialize and become ready.

Root Causes • An RCS defined error condition, indicating homing or motion problems.

Service Resolution Steps

1 Perform DR012 - RCS Initialization Error on page 344.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS) 2 Library Chassis

236 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 263: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT013

DT013 - RCS Calibration Failure

Description GUI Description: The library is unable to calibrate the position of a storage magazine or tape drive.Explanation: The robotic control subsystem cannot successfully calibrate the position of a storage magazine or tape drive.

Detection Scenarios • The RCS reported an error code when the RCS was requested to initialize and become ready.

• The RCS reported an error code indicating that the robot may not be installed level in its Y-track.

Root Causes • An RCS defined error condition, due to the robot position or magazine position so far off the nominal location such that the calibration search pattern cannot locate the target. All motion and sensing appears to be normal.

• Damaged teach target within a magazine. • Problem with the teach sensor. • A bent or improperly installed chassis.

Service Resolution Steps

1 Perform DR013 - RCS Calibration Failure on page 345.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Magazine 2 Y-TRAY W/ ROBOT (RCS) 3 Library Chassis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 237

Page 264: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT014

DT014 - RCS Communication Error

Description GUI Description: The library controller firmware lost communication with the robotics control subsystem.Explanation: The library has lost communication with the RCS. This ticket is generated if the library had previously established a communication link with the robotics control subsystem, but that link has now been lost and cannot be reestablished.

Detection Scenarios • The library firmware did establish communication with the robotics control subsystem but encountered a communication failure during operation and communication could not be re-established.

Root Causes • An SCB to RCS connection problem.• An internal RCS connection problem.• An RCS hardware failure.• An SCB serial communication link failure.

Service Resolution Steps

1 Perform DR014 - RCS Communication Error on page 346.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)2 System Control Board (SCB)3 Library Chassis

238 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 265: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT015

DT015 - RCS Move Failure

Description GUI Description: The robot failed to move a tape cartridge due to an axis motion problem or obstruction.Explanation: An X, Y, Theta motion failure occurred that may or may not be caused by an obstruction. A move failure always implies tape cartridge presence (versus a motion failure which implies a tape cartridge is not present), so since a tape is in the picker, tape recovery must be part of the resolution strategy.

Detection Scenarios • An RCS defined error condition, due to a specified move in the X axis not completing.

• An RCS defined error condition, due to a specified move in the Y axis not completing.

• An RCS defined error condition, due to a specified move in the Theta axis not completing.

Root Causes • An RCS defined error condition indicating a motion control issue or failure.

Service Resolution Steps

1 Perform DR015 - RCS Move Failure on page 347.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 239

Page 266: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT016

DT016 - RCS Motion Failure

Description GUI Description: The robot failed to perform a motion due to an axis motion problem or obstruction.Explanation: An X, Y, Z or Theta motion failure occurred that may or may not be caused by an obstruction. A motion failure always implies that a tape cartridge is not present (versus a move failure which implies a tape cartridge is present), so since a tape is not in the picker, tape recovery is not required as part of the resolution strategy.

Detection Scenarios • An RCS defined error condition, due to a specified motion in the X axis not completing.

• An RCS defined error condition, due to a specified motion in the Y axis not completing.

• An RCS defined error condition, due to a specified motion in the Z axis not completing.

• An RCS defined error condition, due to a specified motion in the Theta axis not completing.

Root Causes • An RCS defined error condition indicating a motion control issue or failure.

Service Resolution Steps

1 Perform DR016 - RCS Motion Failure on page 348.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43. The tape is most likely sticking out of a drive or magazine.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

240 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 267: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT017

DT017 - RCS Imager Error

Description GUI Description: The robot is unable to read barcode label information.Explanation: The robotic imaging device encounters errors and cannot reliably read barcode label information. This issue is most likely due to a camera lens obstruction or cleanliness issue.

Detection Scenarios • An RCS defined error condition, indicating that a picture cannot be analyzed.

• An SCB controller firmware analysis of missing label information.

Root Causes • Foreign material or an obstructing object in the path of vision.• Dust, scratches, or fingerprints on camera lens.

Service Resolution Steps

Perform DR017 - RCS Imager Error on page 350.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 241

Page 268: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT018

DT018 - RCS Component Failure

Description GUI Description: The robotic control subsystem reported an unrecoverable component failure.Explanation: The RCS reported an unrecoverable subsystem component error. The issue may be related to the controller hardware or firmware, servo circuits, robot or Picker Assembly, or imager hardware or firmware.

Detection Scenarios • An RCS defined error condition, indicating that a component failed.

Root Causes • RCS hardware failure. • RCS firmware failure.

Service Resolution Steps

1 Perform DR018 - RCS Component Failure on page 350.

2 Determine whether the problem can be solved by a firmware update. If a firmware problem is the root cause, and a new firmware version exists that addresses the issue, then upgrade the firmware.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

242 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 269: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT019

DT019 - RCS Put Failure

Description GUI Description: The robot appears operational, but failed to properly place a tape cartridge into the destination element.Explanation: The library cannot successfully put/place a tape cartridge into a drive, storage or I/E location and the final “resting place” of the tape cartridge is suspect/unknown. All recovery options have been exhausted. Fundamental servo control seems to be ok.

Detection Scenarios • An RCS defined error condition, indicating that a Put operation was not successful, recovery failed and the tape cartridge may not be properly seated in the picker or destination element.

Root Causes • Damaged magazine.• Damaged cartridge.• Cell is blocked by foreign material.• Incorrect robot position.• Drive loading mechanism not working properly.• A variety of picker problems such as slipping gears, encoder issues, etc.• A magazine partially removed but sensors still showing magazine

presence.

Service Resolution Steps

1 Perform DR019 - RCS Put Failure on page 351.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43. The tape is most likely stuck in the picker.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)2 Magazine (if put is to magazine) or

Drive Sled (if put is to tape drive)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 243

Page 270: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT020

DT020 - RCS Get Failure

Description GUI Description: The robot appears operational, but failed to properly pick a tape cartridge from the source element.Explanation: The library cannot successfully get a tape cartridge from a drive, storage or I/E (I/O) location. The final “resting place” of the tape cartridge is suspect/unknown. All recovery options have been exhausted. Fundamental servo control seems to be an issue, resulting in the library reporting a NOT READY library condition.

Detection Scenarios • An RCS defined error condition, indicating that a Get operation was not successful, recovery failed and the tape cartridge may not be properly seated in the picker or source element.

Root Causes • Picker has bad y gears so it is not at the height it thinks it is at.• A variety of picker problems such as slipping gears, encoder and servo

control issues, etc.

Service Resolution Steps

1 Perform DR020 - RCS Get Failure on page 352.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43. The tape most likely is partially removed from the source.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

244 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 271: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT021

DT021 - RCS Put Problem

Description GUI Description: The robot failed to place a tape cartridge to a destination slot, but robotic operation remains functional and the cartridge was recovered to the source or alternate location.Explanation: The RCS could not place a tape cartridge into the intended target drive, storage or I/E location, but returned the tape cartridge either to the source or an alternate target location. Fundamental servo control appears to be operational.

Detection Scenarios • An RCS defined error condition, indicating that a Put operation and its recovery was not successful, but that the tape cartridge was placed successfully back to the source or an alternate target location.

Root Causes • A damaged magazine.• Slot blocked by foreign material.• Calibration problem.• Destination element occupied by a cartridge (invalid inventory).• A variety of picker problems such as slipping gears, encoder issues, etc.

Service Resolution Steps

1 Perform DR021 - RCS Put Problem on page 353.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Magazine (if destination is a magazine) or

Drive Sled (if destination is a tape drive)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 245

Page 272: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT022

DT022 - RCS Get Problem

Description GUI Description: The robot failed to pick a tape cartridge from a source element, but robotic operation remains functional.Explanation: The library cannot successfully get a tape from a drive, storage or I/E (I/O) location. The tape cartridge is still resting in the source location. The robot is operational and can continue operation.

Detection Scenarios • An RCS defined error condition, indicating that the picker cannot get a tape from the source location.

Root Causes • An obstruction that prevents the picker fingers from getting into the tape grooves.

• A bad tape that is jammed and stuck in the slot.• A damaged slot or drive that will not release the tape.• A magazine partially removed but sensors still showing magazine

presence.

Service Resolution Steps

1 Perform DR022 - RCS Get Problem on page 354.2 If source location is a tape drive, run the robot test to see if this

resolves the problem (see Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests on page 213).

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Magazine (if source location is a magazine)2 Y-TRAY W/ ROBOT (RCS) (if source location is a tape drive)

246 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 273: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT023

DT023 - RCS Cartridge Presence

Description GUI Description: The robot appears operational, but a tape is stranded in the picker mechanism and its origin is not known.Explanation: RCS sensors signal tape cartridge presence but the robot is logically not expecting any cartridge presence. Robot operation seems functional, but the tape cartridge cannot be returned to its home or source location, nor can it be placed into an alternate or destination slot.

Detection Scenarios • An RCS defined error condition, indicating that the robot initialized and discovered that the tape presence sensor detected a tape cartridge, yet a cartridge home location is not known.

• An RCS defined error condition, indicating that the system has tried to recover from a Put failure and tried to return the tape to a home slot, however the home slot recovery logic completed without recovery options, such as a source slot being a drive or the import/export area being open, full, or not installed.

• An RCS defined error condition, indicating that the tape presence sensor and sensing circuit is falsely representing the presence of a tape cartridge.

Root Causes • Power loss during move with media and library logic cannot legitimately return it to the proper cell.

• Power loss during move with media and the robot fails during recovery operations.

• Physical contamination such as dust and debris on the sensor gives a “false full state”

• Various electrical failures

Service Resolution Steps

1 Perform DR023 - RCS Cartridge Presence on page 355.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 247

Page 274: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT024

DT024 - RCS Cartridge Loss

Description GUI Description: The library determined that a tape cartridge was lost during a move operation, requiring manual intervention to recover the tape cartridge from its current location.Explanation: The library detected a condition where a tape cartridge move operation did not succeed and the location of the tape cannot be determined or verified. The most likely cause for this ticket is that a move operation to or from a drive resulted in the picker not detecting cartridge presence, while the drive also no longer reports tape presence. The location of the cartridge is no longer known and the RCS will transition to NOT READY to prevent further motion that could damage the tape cartridge. The RCS cannot transition to the READY state until the tape cartridge is found and removed from the robot's motion mechanism.

Detection Scenarios • An RCS defined error condition, indicating that the location of a tape cartridge is not known.

Root Causes • Drive reported cartridge status and RCS picker status both indicating that a tape cartridge is not present after a drive load or unload operation.

Service Resolution Steps

1 Perform DR024 - RCS Cartridge Loss on page 356.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)

248 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 275: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT030

DT030 - I/E Unlock Failure

Description GUI Description: The robot control subsystem was unable to unlock an I/E magazine lock.Explanation: The library initiated an I/E unlock operation, but the robot failed to unlock the requested I/E magazine.

Detection Scenarios • An RCS defined error condition, indicating that the robot did not succeed in unlocking the I/E magazine.

Root Causes • Locking mechanism not working properly.• Robot motion blocked from pushing I/E unlock mechanism.

Service Resolution Steps

1 Perform DR030 - I/E Unlock Failure on page 357.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)2 Library Chassis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 249

Page 276: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT040

DT040 - VPD Information Missing

Description GUI Description: The library VPD information cannot be retrieved from the primary storage location, preventing the library from proper initialization and operation.Explanation: The library failed to retrieve vital product data (VPD) information from the Operator Panel (Display Assembly Board) EEPROM storage location. VPD information is retrieved at first boot up from a “cleared to ship” condition in order to establish SN, WWN, brand and service tag VPD information and program the installed SCB and RCS with such data for future comparison on subsequent boot up operations to confirm that the RCS and SCB stored information matches the chassis VPD, which allows the library to determine if an SCB, RCS, or library chassis replacement occurred.

Detection Scenarios • At first boot up from clear to ship, the library must establish VPD information to program VPD information on the installed SCB and RCS.

• During subsequent boot sequences, the library can consolidate VPD information between RCS and SCB, but if the RCS is not programmed or the SCB is not programmed (due to being replaced) with VPD information, the library cannot initialize.

Root Causes • VPD not programmed.• Operator Panel (Display Assembly) hardware or communication

problem

Service Resolution Steps

Perform DR040 - VPD Information Missing on page 359.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Library Chassis

250 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 277: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT041

DT041 - VPD Information Warning

Description GUI Description: The library's VPD information cannot be retrieved from the primary storage location, but the library is able to initialize and continue operation.Explanation: The library failed to retrieve vital product data (VPD) information from the Operator Panel (Display Assembly Board) EEPROM storage location, but RCS and SCB stored information matches and the library can continue to operate with VPD information stored on the SCB.

Detection Scenarios • During a library boot sequences, the library could not retrieve VPD information from the Display Assembly, but was able to consolidate VPD information between RCS and SCB, and apply the VPD information stored on the SCB.

Root Causes • VPD not programmed.• Operator Panel (Display Assembly) hardware or communication

problem.

Service Resolution Steps

Perform DR041 - VPD Information Warning on page 359.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Library Chassis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 251

Page 278: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT042

DT042 - VPD Information Changed

Description GUI Description: The library’s VPD information changed, possibly requiring host application configuration changes.Explanation: The library retrieved vital product data (VPD) information from the Operator Panel (Display Assembly Board) EEPROM storage location, but the VPD information differs from the RCS and/or SCB stored information. This Diagnostic Ticket informs the user that SCB stored configuration data may not be valid, as either and most likely the chassis was replaced and the previous SCB has been transferred to this new chassis, or an SCB from another library has been incorrectly installed in this different library. The SCB stored configuration information has not been reset. If the chassis was replaced, the configuration data is still valid and applies, however, license keys need to be re-entered in support of the new chassis serial number, and while VPD information for the library SN and WWNN will be applied and saved automatically, host application configurations may have to be updated to support the new VPD information.

Detection Scenarios • At boot up the library retrieved the chassis stored VPD, but the SCB stored information did not match the VPD information stored on the SCB.

Root Causes • Library Chassis was replaced and the existing SCB from the previous library chassis was re-installed.

• An SCB was incorrectly installed from a different library.

Service Resolution Steps

Perform DR042 - VPD Information Changed on page 360.

Possible CRUs/FRUs None

252 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 279: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT045

DT045 - Chassis Component Failure

Description GUI Description: The library detected a component failure within the library chassis.Explanation: The library controller detected a failure that is associated with a library chassis component, such as invalid signal and sensor input, cabling and connection issues, or chassis configuration issues.

Detection Scenarios • Library firmware detects invalid or failing signal and sensor input.• The SCB persistence matches chassis VPD information, but chassis

signal input contradicts such 3U or 6U configuration.• Chassis VPD retrieval fails and SCB persistence matches RCS VPD

information, but chassis signal input contradicts the SCB assumed 3U or 6U configuration.

• Chassis signaling indicates 3U, but magazine presence signaling shows missing magazine number 3 and/or 4.

Root Causes • Defective library chassis module or internal connection issues.• I/O signal problem.• SPI interface error.

Service Resolution Steps

Perform DR045 - Chassis Component Failure on page 361.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Library Chassis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 253

Page 280: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT046

DT046 - Chassis Magazine Unlocked

Description GUI Description: The library detected an unexpected magazine unlock and removal.Explanation: The library detected an unexpected magazine unlock and removal. This Diagnostic Ticket is caused by a user manually unlocking a magazine, without requesting and indicating any unlock and removal request via the local operator panel or remote user interface functionality.

Detection Scenarios • During library operations, sensors indicate that a magazine was pulled, despite the library not having been instructed to perform a magazine unlock operation.

Root Causes • User initiated a manual magazine unlock operation.• Hardware/sensor failure indicating a missing or extended magazine.

Service Resolution Steps

Perform DR046 - Chassis Magazine Unlocked on page 362.

Possible CRUs/FRUs None

254 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 281: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT050

DT050 - SCB Hardware Failure

Description GUI Description: The library detected a System Control Board hardware failure.Explanation: The library encounters an error which appears to be isolated to a hardware issue on the SCB itself.

Detection Scenarios • Code detects that drive communication UARTS are missing to support drive communication in a 6 U library.

Root Causes • Incorrect SCB installed in 6U library.

Service Resolution Steps

Perform DR050 - SCB Hardware Failure on page 363.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 System Control Board (SCB)

Quantum Scalar i40 and Scalar i80 Maintenance Guide 255

Page 282: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT051

DT051 - SCB Clock Failure

Description GUI Description: The library's real-time clock (RTC) has failed and while the library system time may appear to be set correctly, accurate time will be lost following a power cycle or reboot.Explanation: While setting the library time, the library detected an error with the real time hardware clock (RTC). This type of error will allow the library system time to be changed, but the time will not be set correctly following a power cycle or reboot.

Detection Scenarios • Library firmware determined that setting the hardware clock failed, though the system time may appear to have been set correctly.

Root Causes • The hardware clock on the SCB has failed.

Service Resolution Steps

Perform DR051 - SCB Clock Failure on page 364.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 System Control Board (SCB)

256 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 283: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT052

DT052 - New Library Control Firmware Available

Description GUI Description: The library detected that newer library control firmware is available for a library control firmware update.Explanation: The library is configured to check the Quantum.com Web site to determine if new library control firmware is available. If a newer version than currently installed is found, this diagnostic ticket is displayed to inform the user of the option to install a newer library control firmware version. The ticket will be shown again once an even newer version of library control firmware is available again.

Detection Scenarios • Library firmware determined that newer library control firmware is available on the Quantum.com Web site

Root Causes • New library control firmware is available.

Service Resolution Steps

Perform DR052 - New Library Control Firmware Available on page 365.

Possible CRUs/FRUs 1 None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 257

Page 284: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT055

DT055 - E-mail Notification Error

Description GUI Description: The library initiated an e-mail notification but the message did not reach its destination.Explanation: The library supports e-mail configuration to send ticket alerts and issue snapshot attachments and/or Advanced Reporting reports to a specified address via a configured SMTP e-mail server. The library will report this Diagnostic Ticket if it receives any error codes when trying to send out an e-mail. This ticket indicates an issue with the SMTP server configuration or customer network, but does not indicate a library failure. Note that the library cannot detect all errors that could occur on a network, but can determine if the e-mail was successfully sent to the mail server on the network.

Detection Scenarios • Any time a Diagnostic Ticket is generated and the library has been configured to generate a RAS e-mail.

• Any time an Advanced Reporting notification has been configured and the scheduled sending of such log(s) experiences an error.

Root Causes • E-mail configuration settings on the library are not correct.• The library is not connected to the network.• Library is plugged into the wrong network port.• Network cable is damaged.• E-mail server is down.• Configuration error on the customer's network.

Service Resolution Steps

Perform DR055 - E-Mail Notification Error on page 365.

Possible CRUs/FRUs None

258 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 285: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT057

DT057 - Cartridge Inventory Error

Description GUI Description: The library control firmware performed a cartridge inventory but cannot determine proper element status of the magazine slot.Explanation: The library is attempting to determine cartridge presence at a magazine slot, but is unable to read either the magazine slot label, which if read, indicates an empty magazine slot, or fails to read a tape cartridge barcode label, which triggers a touch tape operation to determine cartridge presence. Only if such touch tape operation fails would this ticket be presented, as the library would otherwise report either ticket DT066 - Unlabeled Magazine Slot (not implemented yet), or DT074 - Unlabeled Tape Cartridge.

Detection Scenarios • The library imager indicates that a label was not successfully ready at a magazine slot location, either the magazine slot label or tape cartridge label, and the mechanical touch tape sense operation failed.

Root Causes • The imager failed to read a label at a magazine slot AND the touch sense operation failed to operate. Imager issues may be caused by the following:•Imager calibration issues.•Imager field of view blocked.•Tape cartridge barcode label improperly applied or missing.•Magazine slot barcode label improperly applied or missing.

•Library top lid not installed, allowing too much light to enter the unit.

Service Resolution Steps

1 Perform DR057 - Cartridge Inventory Error on page 366.2 Power cycle the library to see if the issue recurs. If it does, replace the

robot.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS))2 Magazine

Quantum Scalar i40 and Scalar i80 Maintenance Guide 259

Page 286: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT058

DT058 - Insert Assignment Warning

Description GUI Description: The library does not have sufficient empty storage slots available to accept all newly inserted cartridges for an import operation to storage elements.Explanation: The Auto or Manual Cartridge Assignment raised a warning because there aren't sufficient available slots in the selected partition. When a new cartridge is inserted into an I/E area, it must either be manually or automatically assigned to a library partition. In the case of a manual cartridge assignment mode, if the selected partition does not have sufficient slots available, the assignment will generate this ticket. In the case of an automatic cartridge assignment mode, this ticket will be generated when no partition has space to import a new cartridge. The library is still operational and a host application may not experience an issue at all, however, if an import will be initiated from a user interface, it will fail as not all cartridges can be moved into the assigned partition, unless cartridges get exported first.

Detection Scenarios • The library firmware that controls and performs tape cartridge assignments detects that there are not enough slots available in the partition(s).

Root Causes • The logical library partition does not have enough empty storage slots available to accept all tape cartridges for an import operation.

Service Resolution Steps

Perform DR058 - Insert Assignment Warning on page 367.

Possible CRUs/FRUs None

260 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 287: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT059

DT059 - Auto-Cleaning Failure

Description GUI Description: The library detected a problem during an automatic cleaning operation.Explanation: When the library is configured for Automatic Cleaning, tape drives requesting cleaning will be automatically cleaned. In the event the cleaning operation fails, due to various drive or cleaning cartridge issues, or even a robotic motion issue, this Diagnostic Ticket will be generated to alert the user that a drive cleaning operation did not succeed. This ticket will identify the cartridge or drive as a possible culprit, since any motion issue would cause a separate ticket identifying the RCS FRU.

Detection Scenarios • No eligible cleaning cartridge found.• Auto Clean mechanism fails.

Root Causes • No cleaning cartridge available or only invalid, incorrect, missing or expired cleaning tapes available.

• Cartridge motion error.

Service Resolution Steps

Perform DR059 - Auto-Cleaning Failure on page 367.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 261

Page 288: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT060

DT060 - Cartridge Return Failure

Description GUI Description: A tape cartridge assigned to the System partition cannot be returned to its source location and may appear within an element of a logical library partition.Explanation: The library performed an operation with a “system assigned” tape cartridge and cannot successfully put/place a tape cartridge back to its originating location. The tape cartridge may be exposed/visible to a logical library partition and operator intervention is required to move the cartridge back to its originating source location.

Detection Scenarios • The robot control code moved a system assigned cartridge but was unable to return it to the originating source location.

Root Causes • Open I/E area.• Cell is blocked by foreign material.• Missing or damaged magazine.• A magazine partially removed but sensors still showing magazine

presence.• Incorrect robot position.• Drive unloading mechanism not working properly.• A variety of picker problems such as slipping gears, encoder issues, etc.• Damaged cartridge.

Service Resolution Steps

1 Perform DR060 - Cartridge Return Failure on page 368.2 If the library is a Scalar i80, switch out the upper and lower magazines

to see if the same magazine shows as missing. If the same magazine shows missing, the problem is the chassis. If a different magazine shows missing, the problem is the magazine.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)2 Drive Sled (if source location is a tape drive) or

Magazine (if source location is a magazine slot)

262 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 289: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT065

DT065 - Missing Magazine

Description GUI Description: A library storage magazine is not installed.Explanation: At boot time (library initialization time), the library detects that at least one magazine is extended or missing, possibly preventing slot access for one or more logical library partitions.

Detection Scenarios • Magazine presence sensor input indicating an extended or missing magazine.

Root Causes • A magazine is pulled and extending from the library.• A magazine is pulled and removed from the library. • A number of electrical hardware failures in the magazine presence

detection.

Service Resolution Steps

1 Perform DR065 - Missing Magazine on page 369.2 If the library is a Scalar i80, switch out the upper and lower magazines

to see if the same magazine shows as missing. If the same magazine shows missing, the problem is the chassis. If a different magazine shows missing, the problem is the magazine.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Magazine2 Library Chassis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 263

Page 290: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT067

DT067 - Magazine Unlock Failure

Description GUI Description: The robot control subsystem was unable to unlock a storage magazine.Explanation: The library initiated a storage magazine unlock operation, but the robot failed to unlock the requested magazine.

Detection Scenarios • An RCS defined error condition, indicating that the robot did not succeed in unlocking storage magazine.

Root Causes • Locking mechanism not working properly.• Robot motion blocked from pushing storage magazine unlock

mechanism.

Service Resolution Steps

1 Perform DR067 - Magazine Unlock Failure on page 370.2 If a cartridge is stuck, perform Lodged Tape Removal Instructions on

page 43.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Y-TRAY W/ ROBOT (RCS)2 Library Chassis

264 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 291: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT068

DT068 - Magazine Unlock Warning

Description GUI Description: The library unlocked a storage magazine, but magazine removal was not detected.Explanation: The library initiated an unlock operation for a storage magazine and the robot successfully unlocked the magazine, but magazine removal was not detected within the defined time frame. The storage magazine remains locked.

Detection Scenarios • After successfully unlocking a storage magazine, sensor information did not detect magazine removal within the allotted time frame.

Root Causes • User did not remove magazine.• Magazine presence sensors do not indicate magazine removal.

Service Resolution Steps

Perform DR068 - Magazine Unlock Warning on page 371.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 265

Page 292: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT070

DT070 - Missing Cleaning Media

Description GUI Description: A cleaning tape cartridge, configured for automatic, library-initiated cleaning operations, is missing from its cleaning slot location.Explanation: Whenever the library is configured for automatic drive cleaning, the cleaning tapes that are imported into the library are not visible to any host and are not part of any partition. Rather, they are assigned to the “system” partition. The user should always use the import and export cleaning tape UI functionality to move cleaning tapes in and out of the configured system cleaning slots. If the library detects during inventory that a system assigned cleaning tape has been manually removed, this Diagnostic Ticket will be used to notify the user that this cleaning resource is now missing.

Detection Scenarios • During a library power up inventory, a previously configured cleaning tape is no longer found.

• After a magazine removal and insertion, the magazine inventory operation does not locate a previously configured cleaning cartridge any longer.

Root Causes • A user manually removed a cleaning tape instead of exporting it with the respective UI functionality.

• A barcode label on a system assigned cleaning tape is not read during an inventory.

• Any scenario where a properly imported system cleaning tape which has not yet been properly exported is detected to be missing based on library inventory operations.

Service Resolution Steps

Perform DR070 - Missing Cleaning Media on page 372.

Possible CRUs/FRUs None

266 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 293: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT071

DT071 - Unknown Cleaning Media

Description GUI Description: A configured cleaning slot contains an unknown tape cartridge which will not be used for automatic library-initiated drive cleaning operations.Explanation: Whenever the library is configured for automatic drive cleaning, the cleaning tapes that are imported into the library are not visible to any host and are not part of any partition. Rather, they are assigned to the “system” partition. The user should always use the import and export cleaning tape UI functionality to move cleaning tapes in and out of the configured system cleaning slots. If the library becomes aware during inventory that an unexpected (non-UI-imported) tape has been inserted into a cleaning slot manually, this ticket will be generated to notify the user that a cleaning slot contains a tape cartridge that will not be used for cleaning operations.

Detection Scenarios • During a library power up inventory, a cleaning slot contains a cartridge that has not been properly imported as a cleaning tape.

• After a magazine removal and insertion, the magazine inventory operation identifies a cartridge that has not been properly imported as a cleaning tape.

Root Causes • A user manually inserted a cartridge into a magazine instead of importing it with the respective UI functionality.

Service Resolution Steps

Perform DR071 - Unknown Cleaning Media on page 372.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 267

Page 294: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT072

DT072 - Invalid Cleaning Media

Description GUI Description: A non-cleaning tape cartridge was used to attempt a drive cleaning operation.Explanation: During a drive cleaning operation, the library determined that the tape cartridge used to clean a drive is actually not a cleaning cartridge. This ticket differs from ticket DT123 - Drive Tape Alert 23 in that this ticket will be generated anytime a non-cleaning tape is used to clean a drive, not just in the case where the drive requires cleaning and posts a Tape Alert 23.

Detection Scenarios • After loading a tape cartridge to clean a drive, the system notices that cleaning has not begun within 30 seconds and the tape was not automatically ejected after the allotted cleaning time period.

Root Causes • User or library attempts to mount a cleaning tape but the tape cartridge is not actually a cleaning tape.

• User mistakenly loads a data tape as a cleaning tape• Inventory or application issue results in data tape cartridge being

loaded when the drive expects a cleaning tape.

Service Resolution Steps

Perform DR072 - Invalid Cleaning Media on page 373.

Possible CRUs/FRUs None

268 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 295: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT073

DT073 - Unassigned Tape Cartridge

Description GUI Description: A tape cartridge has been detected in a storage location that is not assigned to any partition.Explanation: After a library inventory operation, either after boot-up (library initialization) or magazine insertion, library firmware validates and tests whether any cartridges may be located in storage slots outside of any configured logical library partitions. If such condition is detected, then this tape cartridge will be inaccessible to the user and must be manually removed. This Diagnostic Ticket will be generated upon detection of the first occurrence of such condition.

Detection Scenarios • During inventory, a tape cartridge is found in a slot that does not belong to a logical library partition.

Root Causes • Cartridge was manually placed into an unassigned storage slot.• A partition was deleted that contained one or more tape cartridges.

Service Resolution Steps

Perform DR073 - Unassigned Tape Cartridge on page 374.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 269

Page 296: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT074

DT074 - Unlabeled Tape Cartridge

Description GUI Description: The library detected an unreadable or unlabeled tape cartridge.Explanation: During library initialization, or after magazine insertion, the library performs an inventory of magazine slots. An inventory of respective magazines is also performed each time an I/E area closes or a tape drive is inserted. These inventory operations use imager reported barcode label information from the magazine slot label or tape cartridge barcode label to determine element full and empty status. If the imager does not read a label, neither a tape cartridge label nor a magazine slot label, a touch sense operation is performed to determine if a tape cartridge is present. If a cartridge is detected, this ticket is reported to alert of the unlabeled tape cartridge. The library will be able to report FULL element status and allow the cartridge to be moved but any cartridge label reference will be listing “NO_LABEL” on the user interface screens and a SCSI Read Element Status response will not list label/volser information at all.

Detection Scenarios • The imager did not read a label, and the touch sense operation found a tape cartridge.

Root Causes • A tape cartridge does not have a barcode label attached, or the barcode label is damaged and unreadable.

Service Resolution Steps

Perform DR074 - Unlabeled Tape Cartridge on page 375.

Possible CRUs/FRUs Cartridge

270 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 297: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT080

DT080 - Tape Drive Type Changed

Description GUI Description: A configured and assigned drive has been replaced with a drive of a different type. Explanation: A tape drive that is assigned to a partition has been replaced with a tape drive of a different type, where type is defined by the tape drive's vendor, generation and interface. This Diagnostic Ticket is generated to notify the user of the tape drive type change. The tape drive will not be made available or become ready, unless the user reconfigures the partition to accept the new drive type, by removing the currently existing and missing drive from the partition, and then adding the newly inserted drive to the partition.Note: If the drive is not assigned to a partition, this ticket SHOULD NOT

be displayed.

Detection Scenarios • The installation of a tape drive into a powered-up library triggers a drive presence indication and a drive power up sequence allowing the library to compare the installed drive type with the current logical library partition information.

• On boot up the library determines drive presence and type and compares the drive type with the logical library partition information.

Root Causes • User replaced a tape drive assigned to a partition with a tape drive of a different generation, interface or vendor type.

Service Resolution Steps

Perform DR080 - Tape Drive Type Changed on page 376.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 271

Page 298: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT082

DT082 - Tape Drive FW Invalid

Description GUI Description: A tape drive firmware image is not usable for a tape drive firmware update.Explanation: During initialization or when a drive is inserted while the library is operating, the library checks the product firmware level of the installed tape drives and compares that version to the version that it stores internally in its file system. If they are not the same, the library automatically updates the tape drive with this internally stored firmware image. However, the image is missing, corrupt, or got rejected by the tape drive.

Detection Scenarios • The required tape drive firmware image is missing from the library software bundle.

• The required drive firmware image is corrupt.• The automatic update of the tape drive firmware is rejected by the

drive.

Root Causes • Missing tape drive firmware image.• Corrupt tape drive firmware image.• Tape drive rejecting the firmware image as being incorrect or corrupt.

Service Resolution Steps

Perform DR082 - Tape Drive FW Invalid on page 376.

Possible CRUs/FRUs None

272 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 299: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT085

DT085 - Drive Removal Unexpected

Description GUI Description: An unexpected drive sled removal has been detected.Explanation: The library control firmware detected the removal of a tape drive while the drive was online.

Detection Scenarios • The drive presence signal indicates a drive is no longer present.

Root Causes • User removed drive sled without taking the drive offline first.• Rare chassis connectivity issue indicating drive removal and

communication loss.

Service Resolution Steps

Perform DR085 - Drive Removal Unexpected on page 377.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 273

Page 300: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT086

DT086 - Drive Power Loss

Description GUI Description: The library detected a tape drive power loss and cannot communicate with the tape drive any longer.Explanation: The library control firmware detected that a tape drive lost power, despite still being present. Tape drive control and communication is no longer functioning.

Detection Scenarios • The drive is present, but power detection and drive communication fails.

Root Causes • Bad tape drive power connection.• Drive removed, but drive present signal still active.

Service Resolution Steps

Perform DR086 - Drive Power Loss on page 378.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled2 System Control Board (SCB)3 Library Chassis

274 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 301: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT087

DT087 - Drive Communication Error

Description GUI Description: The library cannot communicate with a tape drive; tape drive presence is still detected.Explanation: The library control firmware determined drive presence and drive power, but cannot communicate with the tape drive.

Detection Scenarios • The drive is present and powered, but communication fails.

Root Causes • Power indication is good, but drive is actually not powered up.• Cabling error indicating drive presence, but drive actually removed.• Chassis drive communication link failure.

Service Resolution Steps

Perform DR087 - Drive Communication Error on page 379.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled2 System Control Board (SCB)3 Library Chassis

Quantum Scalar i40 and Scalar i80 Maintenance Guide 275

Page 302: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT088

DT088 - Drive FW Update Failure

Description GUI Description: A tape drive firmware update failed.Explanation: A tape drive firmware update operation failed. If the tape drive image validation succeeded, either the transfer of the image failed, or the drive did not accept the firmware due to being loaded with a tape cartridge, or the library did not detect a change in the tape drive firmware version after the tape drive re-initialized.

Detection Scenarios • A tape drive firmware update operation fails to successfully transfer all data to a tape drive.

• After a drive firmware update, the new version received from the drive does not differ from the old version.

• The drive did not accept the firmware image because the drive is loaded with a tape cartridge which prevents the drive from accepting the new firmware image.

Root Causes • The tape drive image that was used to update the tape drive either manually or via auto-leveling operations was the same as what was already installed on the drive.

• A firmware upgrade tape with an incompatible firmware version (wrong generation, drive type, etc.) was used.

• The firmware image was successfully transferred to the drive, but was not flashed properly within the tape drive.

• Error in drive communication, or other drive-specific error.

• The drive is not accepting the firmware update operation because the drive is currently loaded with a tape cartridge. (HP drive bug: LTO-4 HP drives will fail the firmware update when gen 4 media is present in the drive. The drive will successfully update the same firmware image if media is not present, or the media is less than gen 4 types.)

Service Resolution Steps

Perform DR088 - Drive FW Update Failure on page 380.

Possible CRUs/FRUs None

276 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 303: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT089

DT089 - Drive Sled Fan Failure

Description GUI Description: The fan within the drive sled assembly is spinning too slow or does not rotate at all.Explanation: A drive sled fan seems to be spinning too slow or not at all.

Detection Scenarios • Regular polling/monitoring of the fan indicates a problem.

Root Causes • Hardware failure of fan.• Blocked air flow paths.• Physical fan obstruction.

Service Resolution Steps

Perform DR089 - Drive Sled Fan Failure on page 381.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 277

Page 304: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT090

DT090 - Drive Load Failure

Description GUI Description: A tape drive load operation failed, but robotic motion appeared normal.Explanation: The robot has successfully completed all motion profiles associated with placing a tape cartridge into a drive but the tape drive reports that the tape cartridge did not load.

Detection Scenarios • While checking the status of a drive after a PUT motion profile to the drive completed, the drive does not report back a threading/loading/loaded state.

Root Causes • Defective drive.• Defective tape cartridge.• Motion profile was successful but tape cartridge did not get placed far

enough to trigger the drive's loader mechanism.• Picker dragged cartridge back out of drive but not far enough to

trigger picker cartridge present sensor.

Service Resolution Steps

Perform DR090 - Drive Load Failure on page 382.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

278 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 305: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT091

DT091 - Drive Unload Failure

Description GUI Description: A tape drive failed to unload/eject a tape cartridge, preventing the robot from picking and moving the cartridge.Explanation: The library is expecting the drive to achieve an unloaded state but the drive does not succeed and reported an error when unloading/ejecting the tape cartridge for picker access. This Diagnostic Ticket is ONLY displayed if the tape drive was actually instructed to perform an unload operation and the drive's command response informed of an issue. In the case where the library controller code is determining that the drive is still busy for a defined wait time period and the unload request is not sent to the tape drive, this ticket shall not be generated, but rather the request to unload shall be denied as an illegal request. In the case where the command is issued but the library times out waiting for an unload response, ticket DT097 shall be reported.Note: The library will not wait for the maximum unload time defined by

the drive, as drives may take up to 18 minutes before succeeding or failing the unload/eject operation. The library will only wait for 3 minutes before failing the unload request.

Detection Scenarios • A SCSI Move Medium was issued but the drive does not achieve an unload/eject state after being instructed to unload and eject.

• A UI command was issued to unload or move from a drive, but the drive does not achieve an unload/eject state after being instructed to unload and eject.

Root Causes • The tape drive reports a failure and fails to unload a tape cartridge after the library issued an unload command.

Service Resolution Steps

Perform DR091 - Drive Unload Failure on page 383.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 279

Page 306: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT092

DT092 - Drive Unload Prevented

Description GUI Description: A host issued a SCSI Prevent/Allow Media Removal command which is preventing the drive from unloading a tape cartridge.Explanation: The library is not able to issue an unload command to the drive, because a host issued a Prevent/Allow Medium Removal SCSI command to the tape drive which prevents media removal. This Diagnostic Ticket does not convey a library problem but provides informational details regarding a failed SCSI or UI command request.

Detection Scenarios • Library received a request to unload a tape drive, but tape drive status indicates that media removal is prevented.

Root Causes • A host has issued a Prevent/Allow Medium Removal SCSI command, preventing a user to move the media from the drive.

• A host has issued a Prevent/Allow Medium Removal SCSI command, then reset or restarted which may have orphaned the Prevent Media Removal on the drive.

Service Resolution Steps

Perform DR092 - Drive Unload Prevented on page 384.

Possible CRUs/FRUs None

280 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 307: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT093

DT093 - Drive Control Failure

Description GUI Description: A tape drive failed to accept drive configuration parameters.Explanation: A tape drive control command to configure a drive did not succeed. This Diagnostic Ticket is primarily generated if library managed encryption for the tape drive failed to enable or disable, but may be used for any other control issue that prevents the drive from configuring accordingly.

Detection Scenarios • Library Control firmware received a tape drive response, indicating that the tape drive did not configure as requested.

Root Causes • Drive firmware issue.• Incorrect tape drive firmware version, not supporting encryption.• Mounted tape drive, preventing encryption control.

Service Resolution Steps

Perform DR093 - Drive Control Failure on page 385.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 281

Page 308: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT094

DT094 - Drive Encryption Warning

Description GUI Description: A tape drive request to initiate a library managed encryption key exchange did not provide the required details to service the encryption key request.Explanation: The library controller firmware suspended Encryption Service Request (ESR) monitoring of the tape drive, due to the tape drive having indicated an ESR, but when details were requested from the tape drive, no data was provided. If this issue is encountered twice in a row, ESR monitoring will be suspended for the duration of the tape drive mount session and will be re-enabled when a new tape cartridge is mounted.

Detection Scenarios • Library control firmware received a drive sled event indicating that the tape drive reported an ESR, but details are not reported by the tape drive.

Root Causes • Tape drive firmware may incorrectly report an ESR when none is outstanding, or have a valid ESR, but not have the proper encryption key request details available upon drive sled controller request.

Service Resolution Steps

Perform DR094 - Drive Encryption Warning on page 386.

Possible CRUs/FRUs None

282 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 309: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT095

DT095 - Drive Encryption Failure

Description GUI Description: A library managed encryption key exchange to a tape drive failed.Explanation: A tape drive initiated an encryption key request, but the drive either timed out waiting for a response/key or rejected the encryption key as being invalid.

Detection Scenarios • Library control firmware received a drive response, indicating that the tape drive timed out waiting for the encryption key exchange completion.

• The library controller firmware received a tape drive failure response during an encryption key exchange.

Root Causes • The tape drive timed out waiting for the completion of an encryption key exchange.

• The tape drive responded with a failure message when receiving an encryption key due to receiving an invalid/incorrect encryption key from the EKM server.

• The tape drive responded with a failure message when receiving an encryption key due to an internal tape drive failure or encryption key processing issue.

Service Resolution Steps

Perform DR095 - Drive Encryption Failure on page 387.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 SKM Server

Quantum Scalar i40 and Scalar i80 Maintenance Guide 283

Page 310: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT096

DT096 - Drive Control Path Loss

Description GUI Description: The configured library control path through a tape drive has failed.Explanation: The library’s media changer control path through a tape drive has failed. The host connected to the partition associated with the tape drive can no longer control the library. This ticket is the result of another drive-related issue and displayed to alert of the side effect that the logical library partition is no longer accessible. The drive itself may still be accessible by the host(s) for I/O operations; however, any media changer commands sent via the drive cannot be received by the configured logical library partition.

Detection Scenarios • Drive communication loss between the library and the tape drive.• Drive configuration problem to enable the control path.

Root Causes • Various hardware connection problems inside the drive sled.• Tape drive (brick) firmware bug.

Service Resolution Steps

Perform DR096 - Drive Control Path Loss on page 387.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

284 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 311: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT097

DT097 - Drive Unload Timeout

Description GUI Description: A tape drive did not successfully unload a tape cartridge within the allotted time frame, preventing the robot from picking and moving the cartridge.Explanation: The library is expecting the drive to achieve an unloaded state within 3 minutes of initiating the unload request, but the drive is still rewinding and unthreading the tape. This Diagnostic Ticket is ONLY displayed if the tape drive was actually instructed to perform an unload operation and the drive did not respond with a successful or failed unload response within the allotted time frame. In the case where the library controller code is determining that the drive is still busy for a defined wait time period and the unload request is not sent to the tape drive, this ticket shall not be generated, but rather the request to unload shall be denied as an illegal request. Note: The library will not wait for the maximum unload time defined by

the drive, as drives may take up to 18 minutes before succeeding or failing the unload/eject operation. The library will only wait for 3 minutes before failing the unload request.

Detection Scenarios • A SCSI Move Medium was issued but the drive does not achieve an unload/eject state within the allotted time frame after being instructed to unload and eject.

• A UI command was issued to unload or move from a drive, but the drive does not achieve an unload/eject state within the allotted time frame after being instructed to unload and eject.

Root Causes • The tape drive was instructed to unload the tape cartridge but did not complete the request within the allotted time frame.

Service Resolution Steps

Perform DR097 - Drive Unload Timeout on page 388.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 285

Page 312: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT101

DT101 - Drive Tape Alert 1

Description GUI Description: The tape drive issued a Tape Alert, informing that it encounters read performance issues with the mounted tape cartridge.Explanation: HP drives. The library received a drive generated Tape Alert 1 indicating severe read problems, affecting performance, but no data loss.

Detection Scenarios • The tape drive generated and reported Tape Alert 1.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR101 - Drive Tape Alert 1 on page 389.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

286 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 313: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT103

DT103 - Drive Tape Alert 3

Description GUI Description: The tape drive issued a tape alert, informing the library that it stopped the current read or write operation due to a hard read or write error that the drive cannot correct. Explanation: HP and IBM drives. System determines that the drive has issued a Tape Alert 3 - Hard Error - indicating an unrecoverable read or write error.

Detection Scenarios • The tape drive generated and reported Tape Alert 3.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR103 - Tape Drive Alert 3 on page 391.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 287

Page 314: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT104

DT104 - Drive Tape Alert 4

Description GUI Description: The tape drive issued a Tape Alert, informing that the tape cartridge media can no longer be read or written, or read/write performance is severely degraded.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 4 indicating an unrecoverable read, write, or positioning error that the drive specifically isolates to a the media. For IBM drives, IBM recommends that the severity is critical if accompanied by Tape Alert 39, which may indicate a pulled leader pin. IBM considers Tape Alert flag 4 by itself as a media warning. Since HP drives do not support Tape Alert flag 39, this TA flag needs to be posted independent of any other Tape Alert flags. Resolution text will explain and possibly reference the Tape Alert flag 39 ticket.

Detection Scenarios • The tape drive generated and reported Tape Alert 4.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR104 - Drive Tape Alert 4 on page 391.

Possible CRUs/FRUs None

288 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 315: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT105

DT105 - Drive Tape Alert 5

Description GUI Description: The tape drive issued a Tape Alert, informing that it can no longer read data from the tape cartridge.Explanation: IBM drives. The library received a drive-generated Tape Alert 5 indicating an unrecoverable read error where isolation is uncertain between drive and media.

Detection Scenarios • The tape drive generated and reported Tape Alert 5.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR105 - Drive Tape Alert 5 on page 392.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 289

Page 316: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT106

DT106 - Drive Tape Alert 6

Description GUI Description: The tape drive issued a Tape Alert, informing that it can no longer write data to the tape cartridge.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 6 indicating an unrecoverable write error where isolation is uncertain between drive and media.

Detection Scenarios • The tape drive generated and reported Tape Alert 6.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR106 - Drive Tape Alert 6 on page 393.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

290 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 317: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT109

DT109 - Drive Tape Alert 9

Description GUI Description: The tape drive issued a Tape Alert, informing that it was requested to write to a write-protected tape.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 9, indicating that a write was attempted on a write-protected tape. This Diagnostic Ticket does not convey a library or tape drive problem but provides informational details regarding a failed SCSI or UI command request.

Detection Scenarios • The tape drive generated and reported Tape Alert 9.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR109 - Drive Tape Alert 9 on page 394.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 291

Page 318: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT112

DT112 - Drive Tape Alert 12

Description GUI Description: The tape drive issued a Tape Alert, informing that the tape cartridge format is incompatible with the drive type or host write operation request.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 12 indicating that the media loaded is an unsupported format. In the case of the LTO family of drives, full backward read and write compatibility stopped when LTO 3 was introduced. LTO 3 cannot write in LTO 1 format. Therefore an LTO 1 tape is an unsupported format when trying to write to it with an LTO 3 or LTO 4 drive.

Detection Scenarios • The tape drive generated and reported Tape Alert 12.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR112 - Drive Tape Alert 12 on page 395.

Possible CRUs/FRUs None

292 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 319: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT113

DT113 - Drive Tape Alert 13

Description GUI Description: The tape drive issued a Tape Alert, informing that the tape cartridge in the tape drive experienced a mechanical failure.Explanation: HP drives. The library received a drive-generated Tape Alert 13 indicating that an operation has failed because the tape cartridge in the tape drive experienced a mechanical failure.

Detection Scenarios • The tape drive generated and reported Tape Alert 13.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR113 - Drive Tape Alert 13 on page 396.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 293

Page 320: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT115

DT115 - Drive Tape Alert 15

Description GUI Description: The tape drive issued a Tape Alert, informing that the memory chip in the tape cartridge has failed. Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 15 indicating that MIC (Memory In Cartridge) of the mounted/loaded media is not working properly.

Detection Scenarios • The tape drive generated and reported Tape Alert 15.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR115 - Drive Tape Alert 15 on page 397.

Possible CRUs/FRUs None

294 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 321: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT116

DT116 - Drive Tape Alert 16

Description GUI Description: The tape drive issued a Tape Alert, informing that a tape cartridge unload/eject operation has been requested while a host application requested the tape drive to read or write data.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 16 indicating that an unload operation of a tape drive was triggered while the drive was actively reading or writing. The source of the unload operation could only have been initiated via a GUI command, although the code tests that media is not actually being accessed by a host, but a race condition for an unload operation being issued while the host issues a read/write at the same time may exist.

Detection Scenarios • The tape drive generated and reported Tape Alert 16.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR116 - Drive Tape Alert 16 on page 397.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 295

Page 322: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT118

DT118 - Drive Tape Alert 18

Description GUI Description: The tape drive issued a Tape Alert, informing that the tape cartridge directory is corrupted and that file search performance may be degraded.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 18 indicating that the directory on the tape cartridge has been corrupted and that file search performance will be degraded.

Detection Scenarios • The tape drive generated and reported Tape Alert 18.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR118 - Drive Tape Alert 18 on page 398.

Possible CRUs/FRUs None

296 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 323: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT119

DT119 - Drive Tape Alert 19

Description GUI Description: The tape drive issued a Tape Alert, informing that the tape cartridge media is nearing then end of its calculated useful life.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 19 indicating that the tape cartridge is nearing the end of its calculated useful life.

Detection Scenarios • The tape drive generated and reported Tape Alert 19.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR119 - Drive Tape Alert 19 on page 399.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 297

Page 324: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT120

DT120 - Drive Tape Alert 20

Description GUI Description: The tape drive issued a Tape Alert, informing that it is requesting a cleaning operation before the drive can be used for read/write operations again.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 20 indicating that the drive requires cleaning. This tape alert should be intercepted, such that it not get displayed if the library is configured for automatic cleaning, or the library knows that the host is configured for host-initiated cleaning, such that the tape alert is “held” until the next host move request to the drive and if such move does not move a cleaning tape, cause the tape alert ticket to be generated.

Detection Scenarios • The tape drive generated and reported Tape Alert 20.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms

Service Resolution Steps

Perform DR120 - Drive Tape Alert 20 on page 399.

Possible CRUs/FRUs None

298 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 325: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT121

DT121 - Drive Tape Alert 21

Description GUI Description: The tape drive issued a Tape Alert, informing that it is requesting a cleaning operation at the next convenient opportunity.Explanation: The library received a drive-generated Tape Alert 21 indicating that the drive requests cleaning. This tape alert should be intercepted, such that it not get displayed if the library is configured for automatic cleaning, or the library knows that the host is configured for host-initiated cleaning, such that the tape alert is “held” until the next host move request to the drive and if such move does not move a cleaning tape, cause the tape alert ticket to be generated.

Detection Scenarios • The tape drive generated and reported Tape Alert 21.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms

Service Resolution Steps

Perform DR121 - Drive Tape Alert 21 on page 400.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 299

Page 326: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT122

DT122 - Drive Tape Alert 22

Description GUI Description: The tape drive issued a Tape Alert, informing that the mounted cleaning tape cartridge has expired.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 22, indicating that the loaded cleaning media is expired.

Detection Scenarios • The tape drive generated and reported Tape Alert 22.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithm.

Service Resolution Steps

Perform DR122 - Drive Tape Alert 22 on page 402.

Possible CRUs/FRUs None

300 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 327: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT123

DT123 - Drive Tape Alert 23

Description GUI Description: The tape drive issued a Tape Alert, informing that an invalid cleaning tape has been used for a tape drive cleaning operation.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 23 indicating that the drive was expecting a cleaning tape but the loaded cartridge is not a cleaning tape.

Detection Scenarios • The tape drive generated and reported Tape Alert 23.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms

• User or library attempts to mount a cleaning tape but the tape is not actually a cleaning tape.

• User mistakenly loads a data tape as a cleaning tape.• Inventory or application issue results in data tape being loaded when

drive expects cleaning tape.

Service Resolution Steps

Perform DR123 - Drive Tape Alert 23 on page 402.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 301

Page 328: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT130

DT130 - Drive Tape Alert 30

Description GUI Description: The tape drive issued a Tape Alert, informing that it encountered a hardware fault that requires a tape drive to be reset to recover.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 30 indicating a hardware error that requires a drive power cycle or reset before the drive might recover to a usable state.

Detection Scenarios • The tape drive generated and reported Tape Alert 30.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR130 - Drive Tape Alert 30 on page 404.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

302 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 329: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT131

DT131 - Drive Tape Alert 31

Description GUI Description: The tape drive issued a Tape Alert, informing that it encountered a hardware fault, which is not read/write related, requiring a tape drive power cycle operation to recover.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 31 indicating a hardware error that requires a drive power cycle before the drive might recover to a usable state.

Detection Scenarios • The tape drive generated and reported Tape Alert 31.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR131 - Drive Tape Alert 31 on page 405.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 303

Page 330: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT133

DT133 - Drive Tape Alert 33

Description GUI Description: The tape drive issued a Tape Alert, informing that it requires the tape cartridge to be ejected for error recovery.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 33 indicating that the drive requires a tape to be ejected in order to resolve a problem.

Detection Scenarios • The tape drive generated and reported Tape Alert 33.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR133 - Drive Tape Alert 33 on page 405.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

304 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 331: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT136

DT136 - Drive Tape Alert 36

Description GUI Description: The tape drive issued a Tape Alert, informing that it exceeded a temperature limit.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 36 indicating that the tape drive detected and exceeds a temperature limit.

Detection Scenarios • The tape drive generated and reported Tape Alert 36.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR136 - Drive Tape Alert 36 on page 406.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 305

Page 332: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT151

DT151 - Drive Tape Alert 51

Description GUI Description: The tape drive issued a Tape Alert, informing that the tape cartridge directory has been corrupted during the unload operation and that file search performance will be degraded.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 51 indicating that the directory on the tape cartridge has been corrupted during an unload operation and that file search performance will be degraded.

Detection Scenarios • The tape drive generated and reported Tape Alert 51.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR151 - Drive Tape Alert 51 on page 407.

Possible CRUs/FRUs None

306 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 333: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT153

DT153 - Drive Tape Alert 53

Description GUI Description: The tape drive issued a Tape Alert, informing that a tape system area read failed during a cartridge load operation.Explanation: IBM drives. The library received a drive generated Tape Alert 53 indicating that a tape system area read failed during a load operation.

Detection Scenarios • The tape drive generated and reported Tape Alert 53.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR153 - Drive Tape Alert 53 on page 408.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 307

Page 334: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT155

DT155 - Drive Tape Alert 55

Description GUI Description: The tape drive issued a Tape Alert, informing that it encountered a problem while loading a tape cartridge.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 55, indicating that a tape cartridge load operation failed due to a hardware malfunction. The tape cartridge may be mounted or may actually be stuck in the tape drive.

Detection Scenarios • The tape drive generated and reported Tape Alert 55.

Root Causes • The tape drive has determined and reported a tape drive hardware problem per its internal error analysis algorithms.

• A damaged tape cartridge that cannot be loaded into the tape drive.

Service Resolution Steps

Perform DR155 - Drive Tape Alert 55 on page 408.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

308 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 335: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT156

DT156 - Drive Tape Alert 56

Description GUI Description: The tape drive reported a Tape Alert, informing that it encountered a problem while unloading a tape cartridge.Explanation: HP and IBM drives. The library received a drive-generated Tape Alert 56, indicating that an attempt to unload a tape cartridge failed due to a tape drive hardware malfunction preventing the cartridge from being ejected. The tape cartridge may actually be stuck in the tape drive.

Detection Scenarios • The drive generated and reported Tape Alert 56.

Root Causes • The tape drive has determined and reported a tape drive hardware problem per its internal error analysis algorithms.

• A damaged tape that cannot be unloaded from the tape drive.

Service Resolution Steps

Perform DR156 - Drive Tape Alert 56 on page 409.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 Drive Sled

Quantum Scalar i40 and Scalar i80 Maintenance Guide 309

Page 336: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT158

DT158 - Drive Tape Alert 58

Description GUI Description: The tape drive issued a Tape Alert, informing that a drive firmware error occurred.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 58 indicating the detection of a drive firmware failure.

Detection Scenarios • The tape drive generated and reported Tape Alert 58.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR158 - Drive Tape Alert 58 on page 410.

Possible CRUs/FRUs None.

310 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 337: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT159

DT159 - Drive Tape Alert 59

Description GUI Description: The tape drive issued a Tape Alert, informing that the loaded WORM media failed a media integrity check.Explanation: HP and IBM drives. The library received a drive generated Tape Alert 59 indicating that the mounted WORM media failed a media integrity check.

Detection Scenarios • The tape drive generated and reported Tape Alert 59.

Root Causes • The tape drive has determined and reported a problem per its internal error analysis algorithms.

Service Resolution Steps

Perform DR159 - Drive Tape Alert 59 on page 410.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 311

Page 338: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT165

DT165 - Library Control Path Failover

Description GUI Description: A library control path drive failed, but a failover operation to a configured redundant library control path drive path succeeded.Explanation: An installed Storage Networking (SNW) drive that is configured for a library control path failover has failed. The library control path failed over successfully to a configured redundant drive. Host communication should not have been affected if the host was properly configured in support of the library control path failover configuration. Library control commands are now forwarded via a configured redundant drive.

Detection Scenarios • The drive reported that its host communication port(s) lost connectivity and that host communication is no longer functioning.

• The drive sled controller reported that it can no longer communicate with the installed tape drive.

• The library detected that it can no longer communicate with a drive sled or tape drive.

Root Causes • The drive detected a link failure according to its internal detection algorithms. Possible fibre cable disconnects.

• Unrecoverable tape drive communication problem between drive sled controller and tape drive.

• Unrecoverable drive sled communication problem between the library controller and drive sled controller or tape drive.

Service Resolution Steps

Perform DR165 - Library Control Path Failover on page 411.

Possible CRUs/FRUs None

312 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 339: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT166

DT166 - Library Control Path Warning

Description GUI Description: One of the configured redundant library control path drives did not establish or lost its communication link.Explanation: An installed Storage Networking (SNW) drive that is configured as a primary or secondary library control path drive did not establish a communication link. Either the primary or secondary configured control path is operational, but a redundant path has failed. Host communication can be initiated. This ticket conveys that a redundant control path via the primary or secondary control path drive is not operational, but host communication can be performed via one of the configured redundant library control path drive.

Detection Scenarios • The primary or secondary library control path drive reported an event indicating that a link was not established; however one of the configured library control path drive succeeded in establishing a link.

Root Causes • The drive detected a link failure according to its internal detection algorithms.

• The FC or SAS communication cable is disconnected.• A FC switch or SAS repeater is powered off.

Service Resolution Steps

Perform DR166 - Library Control Path Warning on page 412.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 313

Page 340: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT167

DT167 - Library Control Path Failure

Description GUI Description: A library control path failover event occurred, but neither the primary nor the redundant control path drive was able to establish host communication.Explanation: An installed Storage Networking (SNW) drive that is configured for control path failover reported that its control path connection failed. A failover to the redundant control path drive was attempted but did not succeed. Host communication to the library partition is no longer functioning.

Detection Scenarios • The currently active control path drive reported an event indicating that the communication link was lost. The library attempted to switch to the alternate control path drive, but the redundant drive failed to establish a communication link also.

Root Causes • The active control path drive detected a link failure according to its internal detection algorithms.

• The active control path drive sled controller reported that it can no longer communicate with the installed tape drive.

• The library detected that it can no longer communicate with the active control path drive sled or tape drive.

• The FC communication cables to both drives or switch are disconnected.

• The connected FC switch is powered off.

Service Resolution Steps

Perform DT167 on page 314.

Possible CRUs/FRUs None

314 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 341: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT170

DT170 - EKM License Expiring

Description GUI Description: The installed temporary EKM license is nearing expiration. Explanation: A temporary EKM license has been installed and is nearing expiration.

Detection Scenarios • TBD

Root Causes • The customer installed temporary license is nearing its expiration date.

Service Resolution Steps

Perform DR170 - EKM License Expiring on page 414.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 315

Page 342: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT171

DT171 - EKM License Expired

Description GUI Description: The temporary encryption license expired.Explanation: The grace period for operating with a temporary encryption license has expired. LME capabilities in all LME partitions have been disabled.

Detection Scenarios • TBD

Root Causes • The temporary encryption license expired.

Service Resolution Steps

Perform DR171 - EKM License Expired on page 415.

Possible CRUs/FRUs None

316 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 343: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT172

DT172 - EKM Primary Failover

Description GUI Description: The library performed a successful communication failover to the secondary key server.Explanation: EKM configurations support a primary and secondary key server for High Availability (HA) failover considerations. If communication to the primary key server is interrupted, then the library will automatically switch or fail over to the secondary server. This diagnostic ticket will be generated to notify the user that communication to the primary key server failed and that the library performed a successful failover to the secondary key server.

Detection Scenarios • The library detected that it can no longer communicate with the primary key server and automatically switched to the secondary key server where it established successful communication.

Root Causes • Primary key server is not connected properly.• Primary key server is not configured properly.• Library Ethernet settings are not configured properly.

Service Resolution Steps

Perform DR172 - EKM Primary Failover on page 416.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 EKM Server

Quantum Scalar i40 and Scalar i80 Maintenance Guide 317

Page 344: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT173

DT173 - EKM Request Failure

Description GUI Description: The library is unable to receive a proper response to a Key Server request.Explanation: EKM configurations support a primary and secondary key server for High Availability (HA) failover considerations. If communication to one of these servers fails or an invalid configuration is detected that prevents a successful command response and a failover is not possible or not successful then this ticket will be generated. A separate ticket will be created for each key server that fails.

Detection Scenarios • Library detects that communication with a key server is not successful and a communication failover is not possible.

• 2.Library detects that the key server is not properly configured.

Root Causes • Primary/secondary key server is not connected properly.• Primary.secondary key server is not configured properly.• Library Ethernet settings are not configured properly.• Key server is not configured/restored correctly.

Service Resolution Steps

Perform DR173 - EKM Request Failure on page 416.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 EKM Server

318 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 345: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT174

DT174 - EKM Secondary Failover

Description GUI Description: The library performed a successful communication failover to the primary key server.Explanation: EKM configurations support a primary and secondary key server for High Availability (HA) failover considerations. If communication to the secondary server is interrupted, then the library will automatically switch or failover to the primary server. This diagnostic ticket will be generated to notify the user that communication to the secondary key server failed and that the library performed a successful failover to the primary key server.

Detection Scenarios • When the library detects that it can no longer communicate with the secondary key server and automatically switches to the primary key server where it established successful communication.

Root Causes • Secondary key server is not connected properly.• Secondary key server is not configured properly.• Secondary Ethernet settings are not configured properly.

Service Resolution Steps

Perform DR174 - EKM Secondary Failover on page 418.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 EKM Server

Quantum Scalar i40 and Scalar i80 Maintenance Guide 319

Page 346: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT175

DT175 - EKM Communication Warning

Description GUI Description: The library is unable to successfully monitor the communication path and operation status of a configured key server.Explanation: EKM configurations support a primary and secondary key server for High Availability (HA) failover considerations. If communication fails during background key server path testing, this ticket will be generated. A separate ticket will be created for each key server that fails.

Detection Scenarios • Library detects that communication with a key server is not successful

Root Causes • Primary/secondary key server is not connected properly.• Primary/secondary key server is not configured properly.• Primary/secondary Ethernet settings are not configured properly.

Service Resolution Steps

Perform DR175 - EKM Communication Warning on page 418.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 EKM Server

320 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 347: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT176

DT176 - EKM Mirror Warning

Description GUI Description: A key server reported a communication failure to the alternate key server.Explanation: EKM configurations support a primary and secondary key server for High Availability (HA) failover considerations. If communication between the two servers is interrupted and reported by one or both key servers, the library will report this diagnostic ticket to warn of the fact that key server mirroring among the key servers is not operational.

Detection Scenarios • When the library detects that the key servers no longer communicate with each other.

Root Causes • Primary and secondary key server Ethernet connection interrupted.• Primary and/or secondary key server not operational.

Service Resolution Steps

Perform DR176 - EKM Mirror Warning on page 419.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 EKM Server

Quantum Scalar i40 and Scalar i80 Maintenance Guide 321

Page 348: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT177

DT177 - EKM Server Fault

Description GUI Description: A key server reported a software or hardware fault.Explanation: Attached key servers are monitored in regular intervals for operational status. In the event that a key server is reporting a hardware fault or software issue, this diagnostic ticket will be generated to warn the user of such condition.

Detection Scenarios • Regular background key server status monitoring resulted in a key server response indicating a key server fault.

Root Causes • The key server reports a hardware fault, such as a disk/RAID failure, temperature or voltage problem.

• The key server reports a software fault, such as a process “core” or a database issue.

Service Resolution Steps

Perform DR177 - EKM Server Fault on page 420.

Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.

Dispatch the first part listed below for replacement. If this does not solve the problem, dispatch the second part, and so on, in order. Dispatch only one part (or set of parts) at a time.1 EKM Server

322 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 349: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT178

DT178 - EKM Key Unknown

Description GUI Description: The requested encryption key is not defined to the key server and cannot be provided.Explanation: The key server received a request to respond with a required encryption key, but the key server does not have any entry for the requested key. This diagnostic ticket will be generated to notify the user that the encryption key request failed due to the key server not having a record of the required key.

Detection Scenarios • When the library detects that it can no longer communicate with the secondary key server and automatically switches to the primary key server.

Root Causes • The cartridge was encrypted in a different library and the encryption key has not been imported to the key server when the cartridge was added to the library.

Service Resolution Steps

Perform DR178 - EKM Key Unknown on page 421.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 323

Page 350: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT179

DT179 - EKM Key Set Depleted

Description GUI Description: The library detected that more than 80% of pre-generated encryption keys have been used. Explanation: The library determined that the SKM server is either exceeding the use of more than 80% of server generated encryption keys, or has actually reached the 100% limit, having used up all encryption keys and will no longer be able to serve new encryption keys, unless new keys are generated.For SKM GA, encryption key set generations will need to be initiated via the user, by enabling a new or disabling and then re-enabling at least one partition for library managed encryption. Once SKM mirroring server solutions are available, this Diagnostic Ticket will just become informational or a warning, so the resolution can explain that a new encryption key set was generated and a disaster recovery backup of the keys should be performed.

Detection Scenarios • When the library detects that it exceeds usage of 80% of the encryption key set pre-generated on the primary or secondary SKM server.

• When the library detects that it reached usage of all (100%) encryption keys pre-generated on the primary or secondary SKM server.

Root Causes • Usage of encryption keys exceeds 80% of the pre-generated encryption key set.

Service Resolution Steps

Perform DR179 - EKM Key Set Depleted on page 422.

Possible CRUs/FRUs None

324 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 351: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT180

DT180 - EKM Software Mismatch

Description GUI Description: The library detected a mismatch in installed EKM server software. Explanation: The library determined that the attached, redundant EKM (actually just SKM) servers do not have the same software version installed.

Detection Scenarios • When the library performs an initial logical library partition setup for library managed encryption, a software version mismatch is detected.

• When the library performs SKM server background path diagnostic tests, a software version mismatch is detected.

Root Causes • An SKM server was replaced that does not have the latest software installed.

• An SKM server software update was installed only on one of the redundant SKM servers.

Service Resolution Steps

Perform DR180 - EKM Software Mismatch on page 423.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 325

Page 352: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT181

DT181 - EKM Key Corrupted

Description GUI Description: The library detected one or more corrupted encryption keys in the export/import file. Explanation: The library performed an export or import operation of encryption keys or encryption key certificates and determined that one or more entries in the export/import file are corrupted. As long as other entries are correct and can be successfully imported to an attached EKM server, an import operation will succeed and the detected corrupted encryption key or encryption key certificate entries will be excluded from such import operation. Corrupted entries are logged in an EKM issue log file which can be viewed from the remote UI’s Log Viewer menu selection.

Detection Scenarios • When the library performs an export and collects keys or certificates in an export file, one or more encryption keys, or encryption key certificates, fail the CRC check validation in the export file.

• When the library performs an import of encryption keys or encryption key certificates, one or more encryption keys, or encryption key certificates, fail the CRC check validation in the import file.

Root Causes • Export operation file corruption.• Import operation file corruption.

Service Resolution Steps

Perform DR181 - EKM Key Corrupted on page 423.

Possible CRUs/FRUs None

326 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 353: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT182

DT182 - EKM Key Set Exhausted

Description GUI Description: The library detected that all of the pre-generated encryption keys have been used. Explanation: The library determined that the SKM server has used 100% of server generated encryption keys. The library can no longer retrieve and serve new keys from the SKM server, unless new keys are generated.

Detection Scenarios • When the library detects that it used 100% of the encryption key set pre-generated on the primary and/or secondary SKM server and can no longer service any new encryption key requests.

Root Causes • Usage of encryption keys reached 100% of the pre-generated encryption key set.

Service Resolution Steps

Perform DR182 - EKM Key Set Exhausted on page 424.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 327

Page 354: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT183

DT183 - EKM Key Set Missing

Description GUI Description: The library detected an EKM server configuration problem. Explanation: The library determined that an SKM server is not properly configured and does not contain an encryption key set (template) when a library request to retrieve a new key was made. This issue is most likely the result of a key server re-configuration or replacement without having restored encryption key data.

Detection Scenarios • Upon library initialization, the library detects that one of the attached key server pairs does not have a key template configured, suggesting a server replacement has been performed without restoring previous encryption key information.

• During library operation, a request for a new or possibly used key fails due to a missing key template, suggesting a server replacement has been performed without restoring previous encryption key information.

Root Causes • The library was reconfigured to contact a different EKM server which has not been preconfigured and/or proper encryption key data restored.

• An EKM server was replaced but the key store was not restored with backup data from the previously configured EKM server.

Service Resolution Steps

Perform DR183 - EKM Key Set Missing on page 425.

Possible CRUs/FRUs None

328 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 355: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT184

DT184 - EKM Server Sync Warning

Description GUI Description: The library detected a synchronization issue with an EKM server. Explanation: The library determined that an SKM server is not properly configured and does not contain a valid key (template) pointer when a library request to retrieve a new key was made or the attempt to synchronize the key index pointer encountered an error. This issue is most likely the result of a key server re-configuration or replacement without having followed the correct recovery procedures on the library to synchronize the key pointers.

Detection Scenarios • During library operation, a request for a new key failed due to an unexpected key pointer being returned from a key server, suggesting a server replacement has been performed without performing the required recovery procedure on the library.

• During the attempt to synchronize the encryption key index pointer, an error was encountered.

Root Causes • An EKM server was replaced or restored without following the required procedure on the library to synchronize the encryption key (template) pointers.

Service Resolution Steps

Perform DR184 - EKM Key Server Sync Warning on page 426.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 329

Page 356: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT185

DT185 - EKM Server HTTP Access Blocked

Description GUI Description: The library detected a problem when connecting to the EKM server HTTP port. Explanation: The library attempted to obtain SKM server information such as the server’s serial number which the library requires to complete the SKM server configuration process, but the data could not be retrieved via the HTTP protocol. This issue is most likely the result of the key server or switch/router having access to the HTTP port blocked.

Detection Scenarios • During the library’s SKM server configuration process, the library detects that information cannot be retrieved via the SKM server's HTTP connection path.

• Upon library initialization, the library detects that information cannot be retrieved via the SKM server’s HTTP connection path.

Root Causes • The SKM server has its HTTP port disabled, blocking access to retrieve the required information.

• An Ethernet switch is blocking access to the SKM server’s HTTP port, preventing the library from accessing required information.

Service Resolution Steps

Perform DR185 - EKM Server HTTP Access on page 427.

Possible CRUs/FRUs None

330 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 357: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT186

DT186 - EKM Key Set Extended

Description GUI Description: The library extended the encryption key set used for library managed encryption. Attached EKM servers should be backed up as soon as possible.Explanation: The library determined that the SKM server is exceeding the use of more than 80% of server generated encryption keys. For SKM GA, encryption key set generations were initiated via the user, by enabling a new or disabling and then re-enabling at least one partition for library managed encryption. With I3, automatic key generations will be performed, which if successful, shall generate this ticket to inform the user of the need to back up both SKM servers as soon as possible so that the system won't use keys form the newly created set before they have been properly backed up. Once SKM mirroring server solutions are available, this service ticket will just become informational or a warning, so the resolution can explain that a new encryption key set was generated and a disaster recovery backup of the keys should be performed at the earliest convenience.

Automatic key generation should be repeated if an earlier attempt fails, and as defined in DT179, should stop trying once a threshold of 90% or 95% has been reached, in which case DT179 shall be generated to require the user to perform the key set extensions and react to any failures that may prevent the keys from getting generated.

Detection Scenarios • When the library detects that it exceeds usage of 80% of the last encryption key set pre-generated on the primary or secondary SKM server.

Root Causes • Usage of encryption keys exceeds 80% of the last pre-generated encryption key set.

Service Resolution Steps

Perform DR186- Resolve EKM Server Key Generation on page 428

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 331

Page 358: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT187

DT187 - EKM Server Certificate Expiring

Description GUI Description: The EKM server certificate in support of secure communication will be expiring soon.Explanation: An EKM server certificate in support of secure EKM communication is nearing its expiration date. The certificate will only be available for another 1 to 30 days before it expires. Once the certificate expires, communication with the attached library will not be possible until a new valid certificate is installed.

Detection Scenarios • The installed EKM server certificate used for secure communication shows an expiration date that indicates the certificate is nearing its expiration date and has only a listed number of days (30 or less) left before it expires.

Root Causes • The EKM server communication certificate will expire within 30 days.

Service Resolution Steps

Perform DR187 - EKM Server Certificate Expiring on page 428.

Possible CRUs/FRUs None

332 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 359: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT188

DT188 - Library Certificate Expiring

Description GUI Description: A library certificate in support of secure EKM server communication will be expiring soon.Explanation: A library certificate in support of secure EKM communication with an EKM server is nearing its expiration date. The certificate will only be available for another 1 to 30 days before it expires. Once the certificate expires, communication with the EKM server will not be possible until a new valid certificate is installed.

Detection Scenarios • An installed library certificate used for secure communication with an EKM server shows an expiration date that indicates the certificate is nearing its expiration date and has only a listed number of days (30 or less) left before it expires.

Root Causes • The library’s EKM server communication certificate will expire within 30 days.

Service Resolution Steps

Perform DR188 - Library Certificate Expiring on page 429.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 333

Page 360: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT189

DT189 - Library Certificate Expired

Description GUI Description: A library certificate in support of secure EKM server communication has expired.Explanation: A library certificate in support of secure EKM communication with an EKM server has expired. Communication with the EKM server will not be possible until a new valid certificate is installed.

Detection Scenarios • An installed library certificate used for secure communication with an EKM server shows an expiration date that indicates the certificate expired.

Root Causes • The library’s EKM server communication certificate expired.

Service Resolution Steps

Perform DR189 - Library Certificate Expired on page 430.

Possible CRUs/FRUs None

334 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 361: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT190

DT190 - AR License Expiring

Description GUI Description: The temporary license in support of Advanced Reporting will be expiring soon.Explanation: The temporary license in support of the Advanced Reporting feature is nearing its expiration date. The Advanced Reporting feature will only be available for another 1 to 30 days before it expires. Once the temporary license expires, a permanent Advanced Reporting license needs to be installed to continue Advanced Reporting functionality.

Detection Scenarios • The installed 90-day temporary license in support of Advanced Reporting for customer selection is nearing its expiration date and has only a listed number of days (30 or less) left before it expires.

Root Causes • The temporary license will expire within 30 days.

Service Resolution Steps

Perform DR 190 - Expiring AR License on page 430.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 335

Page 362: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT191

DT191 - AR License Expired

Description GUI Description: The temporary license in support of Advanced Reporting has expired.Explanation: The temporary license in support of the Advanced Reporting feature has expired. Advanced Reporting has been disabled and is no longer selectable for admin user login capabilities. A permanent Advanced Reporting license needs to be installed to continue Advanced Reporting functionality.

Detection Scenarios • The installed 90-day temporary license in support of Advanced Reporting for customer selection expired on or before the current date/time.

Root Causes • The temporary license expired.

Service Resolution Steps

Perform DR 191 - Expired AR License on page 431.

Possible CRUs/FRUs None

336 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 363: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT192

DT192 - Hitachi License Activation

Description GUI Description: The library has been configured for Hitachi-specific features.Explanation: A special “Hitachi” license has been installed which enables/disables Hitachi specific configuration and functionality. The license is provided to Hitachi for installation prior to shipping to their customer base.

Detection Scenarios • An installation of the “Hitachi” license has been detected.

Root Causes • The “Hitachi” license has been applied.

Service Resolution Steps

Perform DR 192 - Hitachi License Activation on page 431.

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 337

Page 364: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT195

DT195 - Media Removal Notification

Description GUI Description: The library detected an expected tape cartridge removal from a configured I/E element.Explanation: The library is configured for Media Security Notification and detected an expected removal of media. Media removal is expected whenever an exported tape cartridge has been physically removed by an operator from an I/E area element.

Detection Scenarios • After I/E elements have been inventoried, the library determined that a previously exported tape cartridge is no longer present.

Root Causes • An exported tape cartridge has been removed from the library.

Service Resolution Steps

Perform DR 195 - Media Removal Notification on page 432

Possible CRUs/FRUs None

338 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 365: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Ticket Error Codes

DT196

DT196 - Media Security Warning

Description GUI Description: The library detected an unexpected tape cartridge removal from the library.Explanation: The library is configured for Media Security Notification and detected an unexpected removal of media. Media removal is not expected if the tape cartridge is no longer found in previously configured storage and drive elements, as well as the medium changer (picker) element itself. Media removal is also not expected from configured I/E area elements, unless the tape cartridge had been moved to such element by robotic motion.

Detection Scenarios • After an inventory operation, the library determined that a previously configured, but not exported, tape cartridge is no longer present.

Root Causes • A tape cartridge has been removed from the library without having been properly exported by the robot.

Service Resolution Steps

Perform DR 196 - Media Security Warning on page 432

Possible CRUs/FRUs None

Quantum Scalar i40 and Scalar i80 Maintenance Guide 339

Page 366: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

Diagnostic Resolutions

The diagnostic resolution strategies described in this section mirror those found in the diagnostic ticket resolution on the library’s Web client (visible to administrative users).

DR000 - Contact Quantum Service

This DR provides customer resolution steps for:

• DT000 on page 231

Problem: This Diagnostic Ticket requires technical assistance.

Please contact the QUANTUM Technical Assistance Center (ATAC) online via our Customer Service Center (CSC) website at www.Quantum.com/csc to open a Service Request.

By telephone,

in the USA: 800-872-3822,

in Europe: 00800-9999-3822.

Note that these numbers are subject to change.

Please see the CSC website for a complete list of phone numbers by country.

You may leave this ticket open or close it and return to it at a later time

DR001 - PS Power Loss This DR provides customer resolution steps for:

DT001 on page 232.

Problem: The facility AC power appears to have failed on a power supply. This can be the result of the facility power actually being off, the AC power cable being disconnected, an actual failure in the power supply, or the result of a power supply removal.

1 Note the Diagnostic Ticket details to determine the Power Supply location.

2 Remove the AC power cord from the power outlet and Power Supply, and then make sure the Power Supply is properly seated and secured.

340 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 367: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Reconnect the AC power cord to the facility power source and library Power Supply. Observe that the Power Supply fault LED illuminates orange if the library is not powered up or green if the library is powered already.

4 If the issue cannot be resolved, contact Service for assistance.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR002 - PS Failure This DR provides customer resolution steps for:

• DT001 on page 232

Problem: An internal hardware problem has been detected in a Power Supply. Either the Power Supply fan or a voltage fault has been detected.

1 Note the Diagnostic Ticket details to determine the Power Supply location and failure condition.

2 If a Power Supply fan failure is reported, check if the fan may be obstructed by foreign material. If no obstruction is found, continue with resolution step 4), otherwise remove the Power Supply fan obstruction and continue operation.

3 If a Power Supply fault is reported, check to make sure the AC power cable is properly connected and the Power Supply is fully secured. If the Power Supply is properly connected and secured, continue with resolution step 4), otherwise properly connect the AC power cord and secure the Power Supply, then continue operation.

4 If the issue could not be corrected, contact Service for a Power Supply replacement. Once the new Power Supply has been received:

a Disconnect the AC Power Cord and remove the defective Power Supply.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 341

Page 368: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

Note: Replacement of a redundant supply can be performed with the library operating. When removing the old Power Supply or installing the new Power Supply, the AC power cord should be disconnected from the facility power outlet.

b Install the new Power Supply, tighten the thumb screws, connect the AC power cord to the Power Supply, and then connect to the facility power outlet.

c Once power is connected, verify that the Power Supply fault LED illuminates orange if the library is not powered up, or green if the library is powered already.

d Power up the library and monitor for reoccurrence of this Ticket.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR010 - RCS Firmware Image Error

This DR provides customer resolution steps for:

• DT010 on page 234

Problem: The normal robotics firmware auto-leveling process was not attempted. This problem is caused by a missing or corrupt robotics firmware image file. The robot cannot initialize.

1 Close this Diagnostic Ticket and consult the user documentation to perform a library firmware upgrade to the current or latest library firmware revision.

2 Wait for the library to complete its initialization sequence.

3 If this ticket reoccurs again following the library firmware upgrade operation, contact Service for assistance with resolving this issue.

342 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 369: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR011 - RCS Auto-Level Failure

This DR provides customer resolution steps for:

• DT011 on page 235

Problem: The normal robotics firmware auto-leveling process did not complete successfully. This problem may be caused by controller communication issues, robotics flash programming errors or other robotics controller hardware

1 Note the issue reason from the Diagnostic Ticket details.

2 If the reason details indicate communication issues, check for other communication related Diagnostic Tickets and resolve such tickets first.

3 If no other Diagnostic Tickets are displayed, or a communication related Diagnostic Ticket cannot be resolved, close this Diagnostic Ticket and power-cycle the library.

4 Observe library initialization and check whether this Diagnostic Ticket reoccurs.

5 If this Diagnostic Ticket is displayed again, contact Service for further assistance.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 343

Page 370: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR012 - RCS Initialization Error

This DR provides customer resolution steps for:

• DT012 on page 236

Problem: The library detected a robotics initialization error during the library initialization sequence. Robotic motion to determine robot positioning did not complete due to a robotics installation, hardware or firmware issue.

1 Verify that the library is installed horizontally level, and that the top library lid and magazines are installed and secured correctly.

2 If a Y-Tray/Robot replacement has been performed, an unrecoverable firmware mismatch between the library controller and robotics controller may exist:

a Make sure the library is updated to the latest library firmware to allow for proper robotics controller firmware auto-leveling.

b Close this Diagnostic Ticket and power-cycle the library.

3 If a Y-Tray/Robot was not replaced, close this Diagnostic Ticket and power off the library:

a Consult the user documentation to remove and insert a drive sled.

b Carefully remove each individual drive sled to determine whether a tape cartridge may be extending from the tape drive, blocking robotic motion.

c If a tape cartridge is extending from the tape drive, remove it and note the drive that contained the tape cartridge.

d Re-insert and secure the removed drive sleds.

e Power up the library.

f If the library initializes, import any removed tape cartridge into the partition that owns the drive from which the tape cartridge was removed.

4 If this Diagnostic Ticket reoccurs after the library attempts to reinitialize, contact Service for further assistance.

344 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 371: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR013 - RCS Calibration Failure

This DR provides customer resolution steps for:

• DT013 on page 237

Problem: The library encountered a problem during the calibration process. The robotic control subsystem cannot successfully calibrate the position of a storage magazine or drive. Robotic motion and sensing control appears to be functional.

1 Verify that the library is installed horizontally level, and that the top library lid, storage magazines and drive sleds are installed and secured correctly.

2 Note the location of the drive or magazine from the Diagnostic Ticket details; then close the Ticket and power off the library.

3 Consult the user documentation to manually unlock and remove either the storage magazine noted in step 2) or a magazine closest to the noted drive; then carefully remove the storage magazine to allow inspection of the magazine or drive.

4 If the calibration failure occurred at a drive sled location, carefully inspect the drive through the removed magazine opening to make sure that no tape cartridge is extending from a tape drive, blocking robotics motion. If a cartridge is extending from a drive, consult the user documentation to remove the drive sled and remove the tape cartridge from the drive; then re-insert and secure the drive sled.

5 If the calibration failure occurred at a magazine location, inspect the removed magazine and its content and make sure that all tape cartridges are fully seated and the noted magazine does not show any obvious damage to any of the five chrome teach targets.

6 Re-insert the storage magazines and power on the library.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 345

Page 372: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

7 If the library initializes, import any removed tape cartridge into the partition that owns the drive from which the tape cartridge was removed.

8 If this Diagnostic Ticket reoccurs after the library attempts to reinitialize, contact Service for further assistance.

9 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR014 - RCS Communication Error

This DR provides customer resolution steps for:

• DT014 on page 238

Problem: The library firmware did establish communication with the robotics subsystem, but encountered a communication failure or communication loss during operation.

1 Check if other Diagnostic Tickets exist which may identify a power loss or other RCS related issue and resolve such Diagnostic Tickets before continuing to the next step.

2 If no other Diagnostic Ticket exists, close this Diagnostic Ticket and power-cycle the library.

3 Once the library initializes, monitor this issue for reoccurrence.

4 If the library does not initialize, follow the resolution instructions for the reported initialization failure Diagnostic Ticket.

5 If the issue cannot be resolved, contact Service for assistance.

346 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 373: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR015 - RCS Move Failure

This DR provides customer resolution steps for:

• DT015 on page 239

Problem: The library detected a positioning error when moving a tape cartridge to a new location. The tape cartridge move operation did not complete; the cartridge location is suspect and cartridge recovery must be performed by manual intervention.

1 Note the Diagnostic Ticket details to determine partition, source and destination location of the move request to identify which elements are referenced.

2 Power off the library and consult the user documentation to manually unlock and remove a storage magazine.

3 Identify the previously noted storage magazine(s) or tape drive(s) involved in the move operation and determine an unreferenced storage magazine for a magazine removal operation. Manually unlock and carefully remove the storage magazine to allow inspection of the previously noted source and destination element.

4 If an unreferenced storage magazine cannot be determined, carefully unlock and remove any storage magazine, taking into account that the removal may be blocked by a protruded tape cartridge or extended picker mechanism. If such magazine removal is obstructed, reseat the magazine and unlock and remove a different storage magazine to gain access to the picker mechanism.

5 View inside the library and determine the location of the tape cartridge.

6 If a tape cartridge is extending from a tape drive, consult the user documentation to remove the drive sled and remove the tape cartridge from the drive; then re-insert and secure the drive sled.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 347

Page 374: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

7 Re-insert the removed storage magazine and power on the library. Wait for the library to complete initialization.

8 If a tape cartridge was not retrieved from the library or drive, automatic cartridge recovery should have occurred during library initialization. Note any new Diagnostic Tickets once the library initialized and resolve such Diagnostic Ticket accordingly.

9 If a tape cartridge was removed from a tape drive, consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

10 Monitor for reoccurrence and contact Service if the issue could not be resolved or the issue repeats.

11 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR016 - RCS Motion Failure

This DR provides customer resolution steps for:

• DT016 on page 240

Problem: The library detected a robotics positioning error in the horizontal (X), vertical (Y), reach (Z), or rotational (Theta) axis and the command request did not complete successfully. A tape cartridge has not been involved in the robotics operation, but manual intervention is required to determine root cause of the positioning failure.

1 Note the Diagnostic Ticket details to determine possible partition, source and destination location of the motion request to identify which elements are referenced.

2 Power off the library and consult the user documentation to manually unlock and remove a storage magazine and manually control picker motion.

348 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 375: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Identify the noted storage magazine(s) or tape drive(s) involved in the robotics motion request and determine an unreferenced storage magazine for a magazine removal. Manually unlock and carefully remove an unreferenced storage magazine to allow viewing of the source and destination element.

4 If an unreferenced storage magazine cannot be determined, carefully unlock and remove any storage magazine, taking into account that the removal may be blocked by a protruded tape cartridge. If such magazine removal is obstructed, reseat the magazine and unlock and remove a different storage magazine to gain access to the picker mechanism.

5 Check for any robotics positioning obstruction by looking through the storage magazine opening.

6 If a tape cartridge is extending from a tape drive, consult the user documentation to remove the drive sled and remove the tape cartridge from the drive; then re-insert and secure the drive sled.

7 Re-insert the removed storage magazine and power on the library. Wait for the library to complete initialization.

8 If a tape cartridge was not retrieved from the library or drive, automatic cartridge recovery should have occurred during library initialization. Note any new Diagnostic Tickets once the library initialized and resolve such accordingly.

9 If a tape cartridge was removed from a tape drive, consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

10 Monitor for reoccurrence and contact Service if the issue could not be resolved or the issue repeats.

11 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 349

Page 376: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR017 - RCS Imager Error

This DR provides customer resolution steps for:

• DT017 on page 241

Problem: The library detected a problem with reading barcode label information. The imager’s camera lens may be dirty or obscured.

1 Contact Service for assistance.

2 Choose from the following:

a Select Back to return to the previous resolution steps.

b Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

c Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR018 - RCS Component Failure

This DR provides customer resolution steps for:

• DT018 on page 242

Problem: The library detected a robotics failure that may require a firmware update or the replacement of the Picker Assembly.

1 Close this Diagnostic Ticket and power-cycle the library.

2 If the library initializes continue operation and monitor for reoccurrence.

3 If this Diagnostic Ticket is displayed again, or the issue reoccurs, contact Service to arrange for the replacement of the Picker Assembly or library firmware update.

4 If a different robotics related Diagnostic Ticket is displayed, follow the resolution instructions of such Diagnostic Tickets.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

350 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 377: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR019 - RCS Put Failure This DR provides customer resolution steps for:

• DT019 on page 243

Problem: The library cannot successfully put/place a tape cartridge into a drive, storage or I/E location and the final “resting place” of the tape cartridge is suspect/unknown. All recovery options have been exhausted. Fundamental servo control seems to be ok.

1 Note the Diagnostic Ticket details to determine the partition and destination location of the move request to identify which destination element is referenced.

2 If the tape cartridge could not be placed into a tape drive:

a Power off the library and consult the user documentation to manually remove and insert a drive sled.

b Carefully remove the identified drive sled to determine whether a tape cartridge may be extending from the tape drive.

c If a tape cartridge is extending from the tape drive, remove it and note the drive that contained the tape cartridge.

d Re-insert and secure the removed drive sled.

e Power up the library and wait for successful library initialization.

f If a tape cartridge was removed from a tape drive, consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

g Monitor for reoccurrence and contact Service if the issue could not be resolved or the issue repeats.

3 If the tape cartridge could not be placed into a storage or I/E element, contact Service for assistance.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 351

Page 378: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR020 - RCS Get Failure This DR provides customer resolution steps for:

• DT020 on page 244

Problem: The library was unable to successfully get/pick a tape cartridge from a drive, storage or I/E location. The final “resting place” of the tape cartridge is suspect/unknown. All recovery options have been exhausted. Fundamental servo control may or may not be ok. The library is no longer reporting READY status.

1 Note the Diagnostic Ticket details to determine the partition and source location of the move request to identify which source element is referenced.

2 Stop all host operations and then close this Diagnostic Ticket and power off the library.

3 If the tape cartridge could not be picked from a storage or I/E element, power up the library and wait for the library to complete successful initialization.

4 If the tape cartridge could not be picked from a tape drive:

a Consult the user documentation to manually remove and insert a drive sled.

b Carefully remove the identified drive sled identified in the Diagnostic Ticket details to determine whether a tape cartridge may be extending from the tape drive.

c If a tape cartridge is extending from the tape drive, remove it.

d Re-insert and secure the removed drive sled.

e Power up the library and wait for the library to complete successful initialization.

5 If a tape cartridge was removed from a tape drive, consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

6 Restart host operations and monitor for reoccurrence of this Diagnostic Ticket.

7 Contact Service if the issue could not be resolved or the issue repeats.

352 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 379: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR021 - RCS Put Problem

This DR provides customer resolution steps for:

• DT021 on page 245

Problem: The library robotics did not successfully put/place a tape cartridge into the intended target drive, storage or I/E location, but either returned the tape cartridge back to the source or an alternate target location. Fundamental servo control appears to be operational.

1 Note the Diagnostic Ticket details to determine the destination location of the move request to identify which drive or magazine slot is referenced.

2 From the remote user interface, select Reports > Library Configuration to locate and view the destination drive or magazine slot location.

3 Consult the user documentation to initiate an unlock operation of a storage magazine.

4 If a move to a drive failed, unlock and carefully remove any storage magazine. Inspect the drive location by looking though the magazine opening to determine any drive obstruction.

5 If a move to a cartridge magazine slot failed, unlock and remove the magazine containing the destination element and inspect the actual destination slot location within the magazine as determined in step 2.

6 If a tape cartridge is extending from a tape drive, consult the user documentation to remove the drive sled and remove the tape cartridge from the drive; then re-insert and secure the drive sled.

7 If the obstruction was corrected or no issue was found, re-insert the removed storage magazine. Wait for the library to complete initialization.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 353

Page 380: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

8 If a tape cartridge was removed from a tape drive, consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

9 If an obstruction or damage was found or a tape cartridge cannot be placed successfully again, contact Service for further assistance.

10 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR022 - RCS Get Problem

This DR provides customer resolution steps for:

• DT022 on page 246

Problem: The library robotics did not successfully get/pick a tape cartridge from a drive, storage, or I/E location. The tape cartridge is still resting in the source location. The robot assembly is still operational and can continue operation.

1 Note the Diagnostic Ticket details to determine the partition and source location of the move request to identify which drive or magazine slot is referenced.

2 From the remote user interface, select Reports > Library Configuration to locate and view the source drive or magazine slot location.

3 Consult the user documentation to initiate an unlock operation of a storage magazine.

4 If a move from a drive failed, unlock and carefully remove any storage magazine. Inspect the drive location by looking though the magazine opening to determine any drive obstruction.

5 If a move from a cartridge magazine slot failed, unlock and remove the magazine containing the source element and inspect the actual source slot location within the magazine as determined in step 2.

354 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 381: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

6 If a tape cartridge is extending from a tape drive, consult the user documentation to remove the drive sled and remove the tape cartridge from the drive; then re-insert and secure the drive sled.

7 If the obstruction was corrected or no issue was found, re-insert the removed storage magazine and power on the library. Wait for the library to complete initialization.

8 If a tape cartridge was removed from a tape drive, consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

9 If an obstruction or damage was found or a tape cartridge cannot be picked successfully again, contact Service for further assistance.

10 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR023 - RCS Cartridge Presence

This DR provides customer resolution steps for:

• DT023 on page 247

Problem: The library detected tape cartridge presence in the picker assembly but the robot is logically not expecting a tape cartridge. Robotic operation seems to be functional, but the tape cartridge presence sensor is indicating tape cartridge presence whose origin is unknown. The tape cartridge cannot be returned to its home or source location, nor can it be placed into an alternate or destination slot.

1 Close this Diagnostic Ticket, then power off the library and consult the user documentation to manually unlock and remove a storage magazine to allow inspection of the picker assembly.

2 Manually unlock and carefully pull and remove a storage magazine to gain viewing access to the picker mechanism.

3 Visually inspect the picker mechanism through the magazine opening to determine cartridge presence.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 355

Page 382: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If a tape cartridge is not found in the Picker Assembly, the cartridge presence sensor may be malfunctioning. Re-insert the removed storage magazine(s) and power on the library. Wait for the library to complete initialization and check if the issue is reported again. If the issue is still reported, contact Service and inform them of a malfunctioning cartridge presence sensor in the picker assembly. If the issue is no longer reported, monitor for recurrence and contact Service if the issue repeats.

5 If a tape cartridge is present in the Picker Assembly, contact Service to assist with the removal and recovery of the tape cartridge.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR024 - RCS Cartridge Loss

This DR provides customer resolution steps for:

• DT024 on page 248

Problem: The library detected an unexpected loss of a tape cartridge. Robotic motion appears operational but cartridge presence detection signals that the tape cartridge is not detected in the source, destination or picker mechanism.

1 Note the Diagnostic Ticket details to determine partition, source and destination location of the move request.

2 Power off the library and consult the user documentation to manually remove and insert a drive sled.

3 Carefully remove each individual drive sled to determine whether a tape cartridge may be extending from the tape drive. If a tape cartridge is extending from the tape drive, remove it and note the drive that contained the tape cartridge. Re-insert and secure the removed drive sleds.

356 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 383: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If the lost tape cartridge has been located and removed from a drive sled, power up the library and consult the user documentation to re-import the tape cartridge back to the partition that owns the tape drive from which the cartridge was removed.

5 If the lost tape cartridge cannot be located, leave the library powered off and contact Service for further assistance.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR030 - I/E Unlock Failure

This DR provides customer resolution steps for:

• DT030 on page 249

Problem: The library attempted an I/E area magazine unlock operation, but the robot was unable to release the locking mechanism. The I/E magazine remains locked.

1 Close this Diagnostic Ticket and repeat the I/E area unlock request.

2 If this Diagnostic Ticket is displayed again, consult the user documentation to unlock and release the complete storage magazine.

3 If the complete magazine could be unlocked, extend the magazine to expose the I/E area and perform the requested insert or remove operation. Re-insert the storage magazine and verify that the magazine gets locked. Close this Diagnostic Ticket and repeat the I/E area magazine unlock request again.

4 If the issue cannot be resolved, contact Service for assistance in troubleshooting magazine lock issues.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 357

Page 384: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR031 - I/E Unlock Warning

This DR provides customer resolution steps for:

• DT040 on page 250

Problem: The library performed a successful I/E area magazine unlock operation, but removal of the magazine could not be detected. The I/E area magazine remains locked.

1 If the I/E area magazine has not been extended for operator access, ignore this Diagnostic Ticket.

2 Validate that the I/E area is indeed not extended for operator access. If the magazine is extended, magazine presence detection may be incorrect. Verify that the library detects magazine presence upon magazine insertion and properly identifies I/E area slot status.

3 If magazine presence detection is incorrect, repeat the unlock and I/E area magazine removal; contact Service for assistance with magazine presence and removal detection if the issue repeats.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

358 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 385: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR040 - VPD Information Missing

This DR provides customer resolution steps for:

• DT040 on page 250

Problem: The library attempted to retrieve Vital Product Data (VPD) information from the primary storage location of the library chassis, but neither the library chassis, nor the System Controller Board (SCB) has valid VPD information stored to continue operation. The library is unable to initialize.

1 Contact Service to schedule a library chassis replacement.

2 If the library configuration had been saved for this library, consult the user documentation to perform a Restore Configuration operation which retrieves and re-establishes the library configuration. Once the configuration is restored, close this Diagnostic Ticket, power-cycle the library and observe library initialization. Note that Diagnostic Ticket DT041 will be displayed to inform of VP information missing in the library chassis; close such Diagnostic Ticket.

3 If the library configuration had not been saved, or the library configuration restore operation fails, contact Service for assistance.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR041 - VPD Information Warning

This DR provides customer resolution steps for:

• DT041 on page 251

Problem: The library attempted to retrieve Vital Product Data (VPD) information from the primary storage location of the library chassis but the operation failed. The library can initialize with valid VPD information stored on the System Controller Board (SCB), however, due to the missing VPD information in the library chassis, the library will not be able to initialize in the future, in the unlikely event that the SCB needs to be replaced.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 359

Page 386: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

1 Contact Service to schedule a library chassis replacement.

2 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR042 - VPD Information Changed

This DR provides customer resolution steps for:

• DT042 on page 252

Problem: The library retrieved Vital Product Data (VPD) information from the primary storage location of the library chassis and determined that the VPD information differs from the VPD information stored on the System Controller Board (SCB). This difference may be the result of a library chassis exchange or an SCB being incorrectly installed from a different library. The library configuration information may no longer be valid.

1 If the issue has been reported due to a library chassis replacement, all SCB saved library configuration information will still match the configuration for the new library chassis. The new library serial number (SN) as well as library and tape drive reported World Wide Node Name (WWNN) or SAS Address information will be automatically updated. The host application may need to be reconfigured to support the new library SN and WWNN, as well as any changed drive addresses. If the library had license keys installed in support of certain functionality, new license keys associated with the new library chassis need to be re-entered. Consult the user documentation to enter any applicable license keys and perform a Save Configuration operation so that the configuration could be restored in future restore recovery scenarios.

2 If the issue has been reported due to an SCB replacement, consult the user documentation to perform a Restore Configuration operation which retrieves and re-establishes the library configuration. If the library configuration has not been saved before, the library needs to be re-configured again as the SCB stored configuration information does not apply.

360 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 387: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 If neither an SCB or chassis replacement had been performed, contact Service for assistance.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR045 - Chassis Component Failure

This DR provides customer resolution steps for:

• DT045 on page 253

Problem: A problem has been detected with the library chassis. A signal or configuration discrepancy was detected which may result in the library not being fully operable.

1 Note the Diagnostic Ticket details for future reference.

2 Contact Service and provide the Ticket details identifying the component failure to assist in determining a possible chassis replacement need.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 361

Page 388: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR046 - Chassis Magazine Unlocked

This DR provides customer resolution steps for:

• DT046 on page 254

Problem: The library detected a magazine removal, but a local or remote user interface request to release a magazine has not been issued. The manual magazine removal override release mechanisms should not be operated during normal operations, but just be used when the library is powered off and user interface magazine release functionality is not accessible.

1 Note the magazine location from the Diagnostic Ticket details.

2 If a magazine removal override mechanism was pushed to release a magazine, no further action is necessary and this Ticket may be closed.

3 If a magazine removal override mechanism was not pushed and a magazine was not pulled, override release mechanisms may be stuck or chassis sensors may be reporting an incorrect magazine removal. To isolate the root cause:

a Close this Ticket and power off the library.

b Consult the library User's Guide to manually push the magazine removal override mechanism, then pull the magazine previously noted from the Ticket details and re-insert the magazine to trigger the locking mechanism.

c Make sure all magazines are fully inserted and locked.

d Power up the library, and once the unit initialized, check if Diagnostic Ticket DT065 is being reported to inform of a missing magazine.

e If Diagnostic Ticket DT065 has been reported, contact Service for further assistance to isolate magazine presence sensor issues.

f If Diagnostic Ticket DT065 has not been reported, monitor this issue for further occurrence. Contact Service for further assistance if this Ticket is reported again and all magazines have been fully inserted and locked

362 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 389: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR050 - SCB Hardware Failure

This DR provides customer resolution steps for:

• DT050 on page 255

Problem: The library detected a failure and isolated the issue to the library's System Control Blade (SCB) hardware.

1 Contact Service for assistance with an SCB replacement order.

2 Once the new SCB has been received, consult the user documentation to perform a Save Configuration operation, so that the library configuration can be restored once the new SCB has been installed in the library.

3 Once the library configuration has been saved:

a Power off the library, disconnect the network cable, and remove the SCB.

b Insert and secure the replacement SCB with its thumb screws, connect the network cable and power up the library.

c Once the library initialized, consult the user documentation to perform a Restore Configuration operation.

4 Once the library activates the restored library configuration, validate that the library configuration is correct. Monitor for reoccurrence.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 363

Page 390: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR051 - SCB Clock Failure

This DR provides customer resolution steps for:

• DT051 on page 256

Problem: The library firmware detected that the real-time hardware clock (RTC) on the System Controller Board (SCB) has failed. The library system time may appear to be set correctly, but accurate time will be lost following a power cycle or reboot.

1 Contact Service for assistance with an SCB replacement order.

2 Once the new SCB has been received, consult the user documentation to perform a Save Configuration operation, so that the library configuration can be restored once the new SCB has been installed in the library.

3 Once the library configuration has been saved:

a Power off the library, disconnect the network cable, and remove the SCB.

b Insert and secure the replacement SCB with its thumb screws, connect the network cable and power up the library.

c Once the library initialized, consult the user documentation to perform a Restore Configuration operation.

4 Once the library activates the restored library configuration, validate that the library configuration is correct

5 Monitor for reoccurrence of this Diagnostic Ticket.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

364 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 391: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR052 - New Library Control Firmware Available

This DR provides customer resolution steps for:

• DT052 on page 257.

Problem: The library detected that a newer library control firmware version is available for a library control firmware update.

1 Visit www.quantum.com and navigate to the library product firmware download screen to download the latest available library control firmware version.

2 Once downloaded, update the library via the Tools > Update Library Firmware.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR055 - E-Mail Notification Error

This DR provides customer resolution steps for:

• DT052 on page 257

Problem: The library has attempted to send an e-mail to a configured or specified e-mail address, but has encountered an error with the network configuration or network connection.

1 Check the e-mail and mail server configuration settings on the library to ensure that all values are correct.

2 If the settings are correct, check to make sure the library is properly connected to the network and make sure the network cable is not damaged.

3 If there are no problems found, contact your network administrator for assistance.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 365

Page 392: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR057 - Cartridge Inventory Error

This DR provides customer resolution steps for:

• DT057 on page 259

Problem: The library is unable to properly map cartridges to their respective element location. Imaging results differ for the same magazine slot location.

1 Note the location of the inventory error from the Diagnostic Ticket details.

2 Close the Diagnostic Ticket and consult the user documentation to unlock and remove the respective storage magazine.

3 Check the location of the inventory error and verify that the cartridge barcode label is unique and not damaged. Make sure the cartridge does not have more than one barcode label attached or visible.

4 Reinsert the storage magazine to retrigger an inventory operation.

5 If the Diagnostic Ticket is displayed again once the inventory operation completes, contact Service for a possible robot/imager replacement.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

366 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 393: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR058 - Insert Assignment Warning

This DR provides customer resolution steps for:

• DT058 on page 260

Problem: The library or library partition does not have sufficient storage elements available at the moment to allow for an import operation of the newly inserted tape cartridges into the library's storage area. If an import operation will be attempted, the operation will fail since one or more inserted tape cartridges cannot be moved to storage elements within a logical library partition.

1 Prior to performing an import operation of the newly inserted tape cartridge(s), export sufficient tape cartridges from the logical library partition to accommodate a tape cartridge import operation.

2 Alternatively, reduce the number of cartridges to import.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR059 - Auto-Cleaning Failure

This DR provides customer resolution steps for:

• DT059 on page 261

Problem: The library's automatic drive cleaning process encountered an error and did not succeed in cleaning a tape drive.

1 Check for other motion related Diagnostic Tickets. If another Diagnostic Ticket involving the tape drive listed in the Diagnostic Ticket details, resolve such Ticket first.

2 If no other related Diagnostic Ticket exists, access the remote user Interface and select Reports > Library Configuration to locate and view the configured cleaning slots.

3 Verify that at least one cleaning cartridge is configured and not expired.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 367

Page 394: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If no cleaning cartridge is configured, or the configured cleaning cartridges have expired, import new cleaning cartridges to continue uninterrupted automatic drive cleaning operations.

5 If cleaning cartridges are properly configured and not expired, close this Diagnostic Ticket and perform a manual drive cleaning operation with a different cleaning cartridge.

6 If this ticket reoccurs following the manual cleaning operation, take the drive offline and contact Service for issue resolution assistance.

7 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR060 - Cartridge Return Failure

This DR provides customer resolution steps for:

• DT060 on page 262

Problem: The library encountered a problem when trying to return a tape cartridge assigned for system use back to its originating source location. User intervention is required to remove the tape cartridge so it won’t interfere with operations in a logical library partition where the tape cartridge is currently located and accessible by a host application.

1 Check for other motion-related Diagnostic Tickets. If another Diagnostic Ticket involving a robot control problem is listed in the Diagnostic Ticket details, resolve such Ticket first.

2 If no other related Diagnostic Ticket exists, view the Diagnostic Ticket details to determine the current location of the tape cartridge, as well as its originating source location to determine whether the cartridge is a cleaning tape configured for automatic cleaning.

3 From the remote user interface, select Reports > Library Configuration to determine the current logical library partition that owns the element where the tape cartridge is currently located.

368 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 395: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If the cartridge is located in a storage magazine, consult the user documentation to perform an export operation of a tape cartridge in the current location identified in step 2 from the logical library partition identified in step 3.

5 If the tape cartridge is located in a tape drive, consult the user documentation to perform a Move operation of a tape cartridge within the logical library partition identified in step 3 from the tape drive identified in step 2. Once the tape cartridge has been moved to a storage location, follow step 4 to export the tape cartridge from the library.

6 If the exported tape cartridge is a system assigned cleaning cartridge, consult the user documentation to import a cleaning tape into the library.

7 If this ticket cannot be resolved, contact Service for further assistance.

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR065 - Missing Magazine

This DR provides customer resolution steps for:

• DT065 on page 263

Problem: The library detected that a storage magazine is missing unexpectedly. Although the library is able to complete initialization and operate normally the magazine should be installed to prevent unintentional access to the robot through the magazine bay opening.

1 If a magazine is truly missing, re-install the magazine and continue operation.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 369

Page 396: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

2 If all magazines are properly installed:

a Close this ticket and power off the library.

b Verify that all magazines are properly seated and inserted.

c Power on the library and check if this Diagnostic Ticket is displayed again.

3 If the issue cannot be resolved, contact Service for assistance with troubleshooting procedures of the magazine sensing circuitry.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR067 - Magazine Unlock Failure

This DR provides customer resolution steps for:

• DT067 on page 264

Problem: The library attempted a storage magazine unlock operation, but the robot was unable to release the locking mechanism. The storage magazine remains locked.

1 Close this Diagnostic Ticket and repeat the storage magazine unlock request again.

2 If this Diagnostic Ticket is displayed again, consult the user documentation to manually release the storage magazine.

3 Once the storage magazine is re-inserted, verify that the magazine gets locked. Close this Diagnostic Ticket and repeat the storage magazine unlock request again.

4 If the issue cannot be resolved, contact Service for assistance with troubleshooting any storage magazine unlock issues.

370 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 397: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR068 - Magazine Unlock Warning

This DR provides customer resolution steps for:

• DT068 on page 265

Problem: The library performed a successful storage magazine unlock operation, but removal of the magazine could not be detected. The storage magazine remains locked.

1 If the storage magazine has not been extended or removed, ignore this Diagnostic Ticket.

2 Validate that storage magazine is indeed not extended or removed. If the magazine is extended, magazine presence detection may be incorrect. Verify that the library detects magazine presence upon magazine insertion and properly identifies storage magazine slot status.

3 If magazine presence detection is incorrect, repeat the unlock and storage magazine removal; contact Service for assistance with magazine presence and removal detection if the issue repeats.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 371

Page 398: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR070 - Missing Cleaning Media

This DR provides customer resolution steps for:

• DT070 on page 266

Problem: The library determined that a cleaning cartridge configured for automatic cleaning operations is missing from a configured cleaning slot.

1 Note the missing tape cartridge's barcode and location information listed in the Diagnostic Ticket details.

2 Verify that Diagnostic Ticket DT074 is not displayed possibly identifying the missing cleaning cartridge as having an unreadable or missing barcode label.

3 If Diagnostic Ticket DT074 identifies the missing cleaning cartridge, close this Ticket and follow the resolution instructions for DT074.

4 If Diagnostic Ticket DT074 is not displayed or referencing the missing cleaning cartridge, locate the missing cleaning cartridge and place it back into the cleaning slot. Alternatively, import a new cleaning cartridge into the library to continue uninterrupted automatic cleaning operations.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR071 - Unknown Cleaning Media

This DR provides customer resolution steps for:

• DT071 on page 267

Problem: The library determined that an unknown tape cartridge is occupying a configured cleaning slot. In order for a cartridge to be a valid cleaning cartridge, it must be imported as a cleaning cartridge via the library operator interface.

1 Note the tape cartridge's barcode information listed in the Diagnostic Ticket details.

372 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 399: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

2 Locate the tape cartridge within the library inventory by selecting Reports > Library Configuration from the remote user interface.

3 Consult the user documentation to unlock the respective storage magazine so that the cartridge can be removed manually; then re-insert the extended storage magazine.

4 Consult the user documentation to import a cleaning cartridge into the library to allow automatic cleaning operations to function properly.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR072 - Invalid Cleaning Media

This DR provides customer resolution steps for:

• DT072 on page 268

Problem: The library detected that a non-cleaning tape, most likely a data tape cartridge, was used to clean a drive.

1 Note the tape cartridge's barcode information listed in the Diagnostic Ticket details.

2 Locate the tape cartridge by selecting Reports > Library Configuration from the remote user interface to display the library configuration and current inventory.

3 If the cartridge is configured for automatic library initiated cleaning operations, consult the user documentation regarding how to export a cleaning tape from the library and how to Import a valid cleaning cartridge for future use.

4 If the cleaning cartridge was configured for application use, consult the user documentation regarding how to export the tape cartridge and how to import a valid cleaning tape for host application use.

5 If a manual drive cleaning operation was performed, replace the tape cartridge with a valid cleaning cartridge and repeat the drive cleaning operation.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 373

Page 400: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR073 - Unassigned Tape Cartridge

This DR provides customer resolution steps for:

• DT073 on page 269

Problem: At least one tape cartridge has been detected in a magazine slot that is not assigned to any logical library partition and is therefore not accessible by any host application and also not accessible from a local or remote user interface command.

1 From the remote user interface, display the library configuration by selecting Reports > Library Configuration.

2 Make a note of the location of all tape cartridges present in magazine slots that are not assigned to any logical library partition.

3 Release the respective storage magazine to allow access to the tape cartridge(s) by selecting Actions > Magazine from the local user interface, or Operations > Release Magazine from the remote user interface.

4 Once the magazine is unlocked, fully extend the magazine from the library and manually remove the noted tape cartridge(s) from the magazine slot(s).

5 After all unassigned cartridges have been removed, reinsert the storage magazine(s), then wait for the library to complete the magazine calibration and inventory.

6 Repeat steps 3) and 4) for all storage magazines that contained unassigned cartridges.

7 If desired, import the removed cartridge(s) back into the logical library partition that should own such tape cartridge(s).

374 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 401: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR074 - Unlabeled Tape Cartridge

This DR provides customer resolution steps for:

• DT074 on page 270

Problem: The library detected at least one unlabeled tape cartridge or unreadable barcode label. The library is able to move such tape cartridges, but will not be able to report proper barcode label information to the user interfaces and host applications.

1 From the remote user interface, display the current library configuration by selecting Reports > Library Configuration.

2 Make a note of all locations showing “No_Label” as the cartridge barcode label information.

3 Perform an export operation of all noted cartridge locations and inspect and correct affixed barcode labels.

4 Import the correctly labeled tape cartridges back into the respective logical library partition.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 375

Page 402: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR080 - Tape Drive Type Changed

This DR provides customer resolution steps for:

• DT080 on page 271

Problem: The library firmware detected that a tape drive assigned to a partition has been replaced with a tape drive of a different type. A tape drive's type is defined by its vendor, generation, and interface.

1 Perform one of the following resolutions to activate the new tape drive:

a Either replace the new tape drive with one that is of the exact type as the original tape drive that was removed, or

b Consult the user documentation to modify the partition by logically removing the original tape drive from the partition's configuration; then adding the new tape drive to the partition's configuration.

2 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR082 - Tape Drive FW Invalid

This DR provides customer resolution steps for:

• DT082 on page 272

Problem: The automatic update of tape drive firmware failed. The tape drive firmware image stored on the library appears to be invalid or does not match/support at least one of the installed drive types.

1 Consult your library User's Guide to download a library software bundle or new tape drive firmware image through the remote user interface.

2 Close this ticket and perform the firmware update procedure outlined in the User's Guide.

3 Reboot the library so that the automatic tape drive update process is performed again upon initialization.

376 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 403: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If this ticket reappears, contact Service for further assistance in resolving this issue.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR085 - Drive Removal Unexpected

This DR provides customer resolution steps for:

• DT085 on page 273

Problem: The library detected a tape drive removal while the tape drive was online. The tape drive presence signal no longer indicates tape drive presence.

1 If the drive sled was removed or reseated intentionally, close this Diagnostic Ticket and verify that the tape drive is operational. Note that the tape drive should be taken offline for proper removal or reseat operations.

2 If the tape drive was not removed or reseated, make sure the drive sled is properly seated and secured:

a Consult the user documentation to take the drive offline.

b From the rear of the library, loosen the drive sled thumb screws of the tape drive and then pull the drive sled backwards to disconnect from the power connection without disconnecting any host interface cables.

c Wait 30 seconds, then re-insert the drive sled and tighten the drive sled thumb screws.

d Check that the rear drive LED is lit. If lit, power is applied and once the tape drive reinitialized, verify that this Diagnostic Ticket is not displayed again. If the issue is resolved, take the tape drive online.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 377

Page 404: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 If this ticket reappears, close it again and move the tape drive to an empty drive bay or swap it with another drive sled to determine if the issue is following the tape drive or remains associated with the drive bay location.

4 If the issue could not be resolved contact Service for a possible drive sled replacement. Once the tape drive arrives, follow the instructions in the user documentation to replace the drive sled.

5 If the Diagnostic Ticket does not reappear, monitor this issue for reoccurrence.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR086 - Drive Power Loss

This DR provides customer resolution steps for:

• DT086 on page 274

Problem: The library detected a tape drive power loss. Tape presence is still detected, but tape drive communication ceased due to a power loss.

1 If the drive sled was temporarily and intentionally removed and reseated, close this Diagnostic Ticket and verify that the tape drive is operational.

2 If the drive sled has not been reseated, close this Diagnostic Ticket and check for any power supply related Diagnostic Tickets.

3 If Power Supply related Diagnostic Tickets are displayed, resolve such tickets first, otherwise reseat the drive sled as follows:

a Consult the user documentation to take the drive offline.

b From the rear of the library, loosen the drive sled thumb screws of the tape drive and then pull the drive sled backwards to disconnect from the power connection without disconnecting any host interface cables.

378 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 405: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

c Wait 30 seconds, then re-insert the drive sled and tighten the drive sled thumbs screws.

d Check that the rear drive LED is lit. If lit, power is applied and once the tape drive reinitialized, verify that this Diagnostic Ticket is not displayed again. If the issue is resolved, take the tape drive online.

4 If this ticket reappears, close it again and move the tape drive to an empty drive bay or swap it with another drive sled to determine if the issue is following the tape drive or remains associated with the drive bay location.

5 If the issue could not be resolved contact Service for a possible drive sled replacement. Once the tape drive arrives, follow the instructions in the user documentation to replace the drive sled.

6 If the Diagnostic Ticket does not reappear, monitor this issue for reoccurrence.

7 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR087 - Drive Communication Error

This DR provides customer resolution steps for:

• DT087 on page 275

Problem: The library can no longer communicate with a tape drive. Tape drive presence and tape drive power is still indicated.

1 If the drive sled was temporarily and intentionally removed and reseated, close this Diagnostic Ticket.

2 If the drive sled has not been reseated, close this ticket and then verify that the drive sled is properly seated and connected:

a Consult the user documentation to take the drive offline.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 379

Page 406: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

b From the rear of the library, loosen the drive sled thumb screws of the tape drive and then pull the drive sled backwards to disconnect from the power connection without disconnecting any host interface cables.

c Wait 30 seconds, then re-insert the drive sled and tighten the drive sled thumbs screws.

d Once the tape drive reinitialized, verify that the drive initialized and whether this Diagnostic Ticket is displayed again. If the issue is resolved, take the tape drive online.

3 If this ticket reappears, close it again and move the tape drive to an empty drive bay or swap it with another drive sled to determine if the issue is following the tape drive or remains associated with the drive bay location.

4 If the issue could not be resolved contact Service for a possible drive sled replacement. Once the tape drive arrives, follow the instructions in the user documentation to replace the drive sled.

5 If the Diagnostic Ticket does not reappear, monitor this issue for reoccurrence.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR088 - Drive FW Update Failure

This DR provides customer resolution steps for:

• DT088 on page 276

Problem: A manual or automatic attempt to update tape drive firmware was not successful. The drive did not accept and validate the new firmware version.

1 Note the Diagnostic Ticket details to determine the cause of the failure.

380 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 407: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

2 If the firmware version seems to be incorrect, verify that the version being used for the upgrade is the correct version for the respective tape drive type and also indicates a different version from what the drive is currently using.

3 If the tape drive version is incorrect, consult the user documentation to download the correct tape drive firmware image to the library for subsequent automatic drive firmware update operations.

4 If the tape drive is currently loaded with a tape cartridge, consult the user documentation to unload and move the tape cartridge from the tape drive.

5 Close this ticket and either reboot the library so that the tape drive upgrade is performed again upon initialization, or consult the user documentation to remove and reinsert the drive sled.

6 If this ticket reappears, contact Service for further assistance.

7 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR089 - Drive Sled Fan Failure

This DR provides customer resolution steps for:

• DT089 on page 277

Problem: The library detected a drive sled fan failure. Proper cooling of the tape drive is affected.

1 Verify from the rear of the library that the drive sled fan is not blocked or obstructed.

2 If an obstruction is found, correct the issue and close this Diagnostic Ticket.

3 If no obstruction is found, close this Diagnostic Ticket and reseat the drive sled to determine if the drive sled needs to be replaced:

a Consult the user documentation to take the tape drive offline.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 381

Page 408: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

b From the rear of the library, loosen the drive sled thumb screws of the tape drive and then pull the drive sled backwards to disconnect from the power connection without disconnecting any host interface cables.

c Wait 30 seconds, then re-insert the drive sled and tighten the drive sled thumbs screws.

d Once the tape drive reinitialized, verify whether this Diagnostic Ticket is displayed again. If the issue is resolved, take the tape drive online.

4 If the issue could not be resolved contact Service for a drive sled replacement. Once the tape drive arrives, follow the instructions in the user documentation to replace the drive sled.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR090 - Drive Load Failure

This DR provides customer resolution steps for:

• DT090 on page 278

Problem: The library's picker mechanism successfully placed a tape cartridge into the tape drive, but the tape drive does not report detection of the cartridge or does not indicate threading/loading of the tape.

1 Attempt a move operation from the tape drive to a storage slot location.

2 Reload the tape cartridge back into the tape drive and if the load succeeds, close this Diagnostic Ticket and monitor the issue for reoccurrence.

3 If the tape cartridge does not load successfully, move the cartridge back to the storage slot location and select a different cartridge for a tape drive load operation.

382 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 409: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If a different tape cartridge loads successfully, the issue must be caused by the original tape cartridge.

5 If a different tape cartridge does not load successfully, the issue must be caused by the tape drive. Unload the tape cartridge and contact Service for assistance with a possible drive sled replacement.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR091 - Drive Unload Failure

This DR provides customer resolution steps for:

• DT091 on page 279

Problem: The library received a request to unload and eject a tape cartridge from a tape drive but the drive reported an unload failure.

1 Note the Diagnostic Ticket details to determine which drive failed the unload/eject operation.

2 Consult the user documentation to issue a drive unload or move command to attempt another drive unload operation.

3 If the requested command succeeds, observe for future occurrences and contact Service if the issue repeats.

4 If the requested command fails again, consult the user documentation to remove the drive sled.

a Check for any drive opening obstruction and assure the cartridge is fully seated within the tape drive.

b Re-insert and secure the drive sled and wait for the drive to fully initialize and become ready.

c Repeat the drive unload or move operation.

d If the tape cartridge still does not unload, contact Service for assistance in manually removing the tape cartridge from the drive.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 383

Page 410: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR092 - Drive Unload Prevented

This DR provides customer resolution steps for:

• DT092 on page 280

Problem: The library has been commanded to perform a cartridge move from a tape drive, but the tape drive is currently preventing any media removal due to having received a SCSI Prevent/Allow Media Removal command to prevent a tape cartridge removal. The library cannot unload and eject the tape cartridge from the tape drive until the host application issues a SCSI Prevent/Allow Media Removal command to allow a tape cartridge unload operation.

1 Determine which host application issued the SCSI Prevent/Allow Media Removal command.

2 Use the host application or a host utility to allow media removal.

3 Restart the failed host application.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

384 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 411: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR093 - Drive Control Failure

This DR provides customer resolution steps for:

• DT093 on page 281

Problem: A tape drive failed to enable or disable a specific tape drive configuration setting.

1 Note the drive sled coordinate and reason details from the Diagnostic Ticket and close the ticket.

2 Verify that the tape drive firmware version is at least at the firmware version referenced in the release notes for the currently installed library firmware version. Update the tape drive firmware if a newer version is required or available.

3 If the reason details indicate that the drive encryption settings were affected:

a Make sure the referenced tape drive is not loaded with a tape cartridge. Unload the tape drive if a tape cartridge is present.

b Make sure the logical library partition is configured for the correct encryption method and no other Diagnostic Ticket is generated against the drive.

4 Consult your user documentation regarding a drive reset operation or drive removal and replacement procedure.

5 Either perform a drive reset operation via the Tools > Diagnostics menu selection or remove the drive sled and then wait 1 minute before re-inserting and securing the same drive sled into its drive bay location.

6 Wait for the drive to initialize and become ready.

7 If the reason details indicated that the drive encryption settings were affected, make sure the drive is now configured for the respective drive encryption method setting by selecting the Reports >Library Configuration menu and clicking on the respective tape drive coordinate to verify that the tape drive encryption method setting is correctly reported.

8 Contact Service for assistance if an issue remains.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 385

Page 412: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

9 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR094 - Drive Encryption Warning

This DR provides customer resolution steps for:

DT094 on page 282

Problem: A tape drive reported that an encryption request needed to be serviced, but the drive did not indicate required encryption key request details. The drive sled controller suspended encryption key exchange request monitoring until the tape cartridge is unloaded.

1 Note the drive sled coordinate from the Diagnostic Ticket and close the Diagnostic Ticket.

2 Unload the tape cartridge from the tape drive.

3 Reload the tape cartridge and restart the host application.

4 If the Diagnostic Ticket displays again, close the ticket and unload the tape drive.

5 Consult the user documentation to reset the tape drive.

6 Once the tape drive is operational again, reload the tape cartridge and restart the host application.

7 If the problem persists, contact Service for further assistance.

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

386 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 413: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR095 - Drive Encryption Failure

This DR provides customer resolution steps for:

DT095 on page 283

Problem: A tape drive reported that an encryption key exchange operation failed. The tape drive either timed out waiting for an encryption key from the EKM server, or rejected the retrieved encryption key.

1 Note the drive sled coordinate and failure reason from the Diagnostic Ticket; then close the ticket.

2 If the failure reason indicates that the drive timed out waiting for a response, consult the user documentation regarding

a host application time-out settings,

b EKM server Key Path Diagnostics to determine EKM server connectivity and operational status.

3 If the Diagnostic Ticket reason does not indicate a time-out issue, restart the host application and retry the operation.

4 If the issue persists, contact Service for further assistance.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR096 - Drive Control Path Loss

This DR provides customer resolution steps for:

• DT096 on page 284

Problem: A library control path through a drive sled has failed. Most likely, a drive sled failure is being reported as a separate problem. Media Changer commands can no longer be received by the configured logical library partition; however, the drive may still be operational for host access.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 387

Page 414: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

It may be possible to reestablish the control path by resetting the drive sled. In libraries with more than one drive within the partition, an option also exists to use an alternate drive as the control path, if your host connection architecture permits it.

1 Determine if other drive related Diagnostic Tickets have been reported against this drive. Resolve such Diagnostic Tickets before resolving this Diagnostic Ticket.

2 Close this Diagnostic Ticket and attempt to reestablish the control path by issuing a reset operation to the drive.

3 Wait for the drive to initialize and become ready.

4 If this Diagnostic Ticket does not reoccur, the problem is resolved and no further action is required.

5 If this Diagnostic Ticket does reoccur, consult the user documentation to switch the control path to an alternate drive to continue operation and contact Service for further assistance in resolving this issue.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR097 - Drive Unload Timeout

This DR provides customer resolution steps for:

• DT097 on page 285

Problem: The library received a request to unload and eject a tape cartridge from a tape drive but the library timed out waiting for a drive response. Although the drive may take up to 20 minutes to complete an unthread and unload/eject operation in the event of encountering various error recovery scenarios to unthread the tape, the library waits for only up to 5 minutes until the unload operation is timed out and a failure gets reported.

1 Note the Diagnostic Ticket details to determine which drive did not complete the unload/eject operation.

388 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 415: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

2 Wait 5 minutes, then issue a drive unload or move command to repeat the drive unload operation.

3 If the operation times out again, wait another 10 minutes, then issue a drive unload or move command to attempt another drive unload operation.

4 If the requested command succeeds, observe for future occurrences and contact Service if the issue repeats.

5 If the requested command fails again, consult the user documentation to remove the drive sled.

a Check for any drive opening obstruction and assure the cartridge is fully seated in the tape drive.

b Re-insert and secure the drive sled and wait for the drive to fully initialize and become ready.

c Repeat the drive unload or move operation.

d If the tape cartridge still does not unload, contact Service for assistance in manually removing the tape cartridge from the drive.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR101 - Drive Tape Alert 1

This DR provides customer resolution steps for:

• DT101 on page 286

Problem: The tape drive detected and reported severe read performance issues. No data has been lost but read performance is degraded. Data may be at risk based on the condition of the media.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 389

Page 416: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

This problem may be caused by

• the specific tape cartridge,

• the specific tape drive, or

• the interaction of the tape cartridge and tape drive.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Check whether Diagnostic Ticket DT103 has also been reported for this tape cartridge.

3 If DT103 has been reported,

a attempt to copy all required data to another tape cartridge.

b discontinue use of the faulty tape cartridge.

c restart the current operation with the new tape cartridge.

4 If DT103 has not been reported,

a Monitor this issue to determine if the issue is caused by the tape cartridge or tape drive.

b Retry the operation with the same tape cartridge in a different tape drive. If the operation continues to cause this Diagnostic Ticket in more than one tape drive, copy all required data to a new tape cartridge and discontinue use of the existing tape cartridge.

c If the tape cartridge is read fine in other tape drives, use a known good tape cartridge to test the tape drive by performing read/write operations from a host application or utility.

d If the problem is reported for the known good tape cartridge, consult the user documentation to clean the tape drive and if the problem persists, contact Service for possible drive sled replacement.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

390 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 417: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR103 - Tape Drive Alert 3

This DR provides customer resolution steps for:

• DT103 on page 287.

Problem: The tape drive detected and reported a hard error. This Tape Alert is reported in conjunction with Tape Alerts 4, 5, or 6.

1 Follow the instructions for the associated Tape Alert 4, 5, or 6 Diagnostic Ticket resolutions.

2 Retire the associated media from service.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR104 - Drive Tape Alert 4

This DR provides customer resolution steps for:

• DT103 on page 287

Problem: The tape drive detected and reported a critical media problem. The tape cartridge is suspect due to failing tape operations. Data can no longer be written or read, or performance is severely degraded. Data may be at risk based on the condition of the tape.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Copy all required data from this tape cartridge to another tape cartridge.

3 Discontinue use of the faulty tape cartridge.

4 Restart the current operation with the new tape cartridge.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 391

Page 418: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR105 - Drive Tape Alert 5

This DR provides customer resolution steps for:

• DT105 on page 289

Problem: The tape drive detected and reported a critical read failure. The tape drive cannot read data from the mounted tape cartridge. Data may be at risk based on the condition of the media.

This problem may be caused by

• the specific tape cartridge,

• the specific tape drive, or

• the interaction of the tape cartridge and tape drive.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Check whether Diagnostic Ticket DT103 has also been reported for this tape cartridge.

3 If DT103 has been reported,

a attempt to copy all required data to another tape cartridge.

b discontinue use of the faulty tape cartridge.

c restart the current operation with the new tape cartridge.

4 If DT103 has not been reported,

a Consult the user documentation to retrieve and save the tape drive log for vendor analysis.

392 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 419: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

b Retry the operation with the same tape cartridge in the same tape drive. If the retry attempt fails, try the operation with the same tape cartridge in a different tape drive. If the operation fails in more than one tape drive, discontinue use of the tape cartridge.

c If the tape cartridge tests fine, test the tape drive. Using a known good tape cartridge, perform read/write operations from a host application or utility.

d If the problem persists, consult the user documentation to clean the tape drive and if the issue still persists, contact Service for assistance and provide the tape drive log for vendor analysis.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR106 - Drive Tape Alert 6

This DR provides customer resolution steps for:

• DT106 on page 290

Problem: The tape drive detected and reported a critical write failure. The tape drive cannot write data to the mounted tape cartridge or encountered an unrecoverable positioning error. Data may be at risk based on the condition of the media.

This problem may be caused by

• the specific tape cartridge,

• the specific tape drive, or

• the interaction of the tape cartridge and tape drive.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Make sure the tape cartridge is not write-protected. If the tape cartridge is write-protected, correct the tape cartridge write-protect switch setting and close this Diagnostic Ticket.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 393

Page 420: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 If the tape cartridge is not write-protected, consult the user documentation to retrieve and save the tape drive log for possible vendor analysis, then perform the following steps:

a Retry the operation with the same tape cartridge in the same tape drive.

b If the retry attempt fails, try the operation with the same tape cartridge in a different tape drive.

c If the operation fails in more than one tape drive, discontinue use of the tape cartridge.

d If the operation succeeded in another tape drive, test the drive by using a known good tape cartridge and performing read/write operations from a host application or utility.

e If the problem persists, contact Service and provide the tape drive log for vendor analysis

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR109 - Drive Tape Alert 9

This DR provides customer resolution steps for:

• DT109 on page 291

Problem: The tape drive detected and reported that the mounted tape cartridge is write-protected, yet the host application attempted to perform a write operation to the tape cartridge.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Determine whether the tape cartridge should be write protected or not.

3 If the tape cartridge should not be write-protected, then export the tape cartridge from the library and correct the problem by manually changing the write-protect switch setting on the tape cartridge.

394 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 421: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If the tape cartridge is correctly set for read only access, investigate your host application configuration to determine why a write operation has been attempted for a read-only tape cartridge.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR112 - Drive Tape Alert 12

This DR provides customer resolution steps for:

• DT112 on page 292

Problem: The tape drive detected and reported that the tape cartridge type or media format is not supported by the tape drive. Several scenarios may cause this problem:

• A firmware cartridge is loaded as data cartridge,

• A cleaning cartridge is loaded as data cartridge,

• A data cartridge is loaded as a firmware cartridge,

• A data cartridge is loaded as cleaning cartridge,

• A wrong tape cartridge generation is loaded into the tape drive.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Export the tape cartridge from the library and validate that an improper tape cartridge was loaded into the tape drive.

3 Import a proper tape cartridge type with supported format and continue with the desired operation.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 395

Page 422: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR113 - Drive Tape Alert 13

This DR provides customer resolution steps for:

• DT113 on page 293

Problem: The tape drive detected and reported that the tape cartridge experienced a mechanical cartridge failure. The tape may be snapped or cut, but the tape cartridge's mechanical failure will not prevent the tape cartridge from being unloaded and ejected.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Unload the tape cartridge from the tape drive; then export the tape cartridge from the library and check for damage.

3 If data from the tape cartridge needs to be reclaimed and copied to another tape cartridge, contact Service for further assistance.

4 If no data needs to be reclaimed, import a new tape cartridge and restart the operation with the newly inserted tape cartridge. Discontinue use of the failed cartridge.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

396 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 423: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR115 - Drive Tape Alert 15

This DR provides customer resolution steps for:

• DT115 on page 294

Problem: A tape drive has determined that the memory in cassette (MIC) has failed. This issue will reduce performance. The tape cartridge memory may be repairable.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Attempt to repair the tape memory by using the host application or host utility to read the entire tape.

3 Once read, initiate an unload operation to the tape drive, which will cause the cartridge memory to be re-written and hereby repair the issue.

4 To verify that the cartridge memory is repaired, attempt to use the tape again for normal read/write operations. If this tape cartridge fails again, copy all required data to a different or new tape cartridge and discontinue use of the failed tape cartridge.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR116 - Drive Tape Alert 16

This DR provides customer resolution steps for:

• DT116 on page 295

Problem: A tape cartridge was manually ejected from a tape drive while the tape was actively accessed or used for read and/or write operations. This issue typically occurs when the tape drive is being serviced, such as having the eject button pushed while a host application was still using the tape drive.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Re-load the tape cartridge back into the tape drive.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 397

Page 424: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Restart the failed host application.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR118 - Drive Tape Alert 18

This DR provides customer resolution steps for:

• DT118 on page 296

Problem: A tape drive has determined that the tape directory is corrupted and that file search performance will be degraded. The tape cartridge directory content may be repairable.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Attempt to repair the tape directory by using the host application or host utility to read the entire tape.

3 Once the tape has been completely read, the tape directory information has been repaired. File search performance should no longer be degraded.

4 To verify that the tape directory has been repaired, monitor tape cartridge usage for normal access and read/write operations. If this tape cartridge fails again, copy all required data to a different or new tape cartridge and discontinue use of the failed tape cartridge.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

398 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 425: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR119 - Drive Tape Alert 19

This DR provides customer resolution steps for:

• DT119 on page 297

Problem: The tape drive detected and reported that the mounted tape cartridge is nearing the end of its calculated useful life.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Schedule a copy operation to transfer all required data from the tape cartridge to a new tape cartridge.

3 Discontinue use of the tape cartridge as it is nearing the end of its useful life.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR120 - Drive Tape Alert 20

This DR provides customer resolution steps for:

• DT120 on page 298

1 Problem: The tape drive determined that it requires cleaning. The tape drive cannot be used for normal operations again until it has been successfully cleaned. The resolution of this issue depends on how the library or partition is configured to perform drive cleaning operations. Note the Diagnostic Ticket details to determine which tape drive reported the issue.

2 If the library is configured for library-initiated automatic drive cleaning, the cleaning process should have been triggered already when the tape drive recommended or required cleaning. However, since the tape drive is now indicating that it requires cleaning, a valid, non-expired cleaning tape may not be available:

a Check for any other cleaning related Diagnostic Tickets and verify that cleaning tapes are properly configured and not expired.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 399

Page 426: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

b Unload the current tape cartridge and perform a drive cleaning operation.

a If the library is not configured for library-initiated automatic cleaning but the host application controls drive cleaning and has cleaning tapes configured within its partition, the host application may not have recognized that the drive recommended cleaning, or valid, non-expired cleaning tapes may not be available:

a Verify that the host application is properly configured to detect drive cleaning requests.

3 Check for any other cleaning related Diagnostic Tickets and verify that cleaning tapes are properly configured and not expired. If library-initiated automatic cleaning and host application controlled cleaning is not configured, perform a manual drive cleaning operation with a valid cleaning tape.

4 If a manual drive cleaning operation triggered this Diagnostic ticket, the cleaning cartridge used for the cleaning operation is invalid. Repeat the cleaning operation with a valid cleaning tape.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR121 - Drive Tape Alert 21

This DR provides customer resolution steps for:

• DT121 on page 299

1 Problem: The tape drive determined that it needs cleaning. The tape drive is able to continue normal tape operations but a cleaning operation should be performed at the earliest convenience. The resolution of this issue depends on how the library or partition is configured to perform drive cleaning operations. Note the Diagnostic Ticket details to determine which tape drive reported the issue.

400 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 427: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

2 If the library is configured for library-initiated automatic drive cleaning, the cleaning process should have been triggered already and this ticket should not have been generated. However, since this ticket is displayed, a valid, non-expired cleaning tape may not be configured or available:

a Check for any other cleaning related Diagnostic Tickets and verify that cleaning tapes are properly configured and not expired.

b Unload the current tape cartridge and perform a drive cleaning operation.

3 If the library is not configured for library-initiated automatic cleaning but the host application controls drive cleaning and has cleaning tapes configured within its partition, the host application may not have recognized that the drive recommended cleaning, or valid, non-expired cleaning tapes may not be available, or the application may have scheduled the cleaning operation. No immediate resolution is required:

a Resolve any other cleaning related Diagnostic Tickets any verify that the host application is properly configured to detect drive cleaning requests.

b Close this ticket and monitor for re-occurrence as this may be an indication that the host application is not initiating cleaning operations as intended.

4 If library-initiated automatic cleaning and host application controlled cleaning is not configured, perform a manual drive cleaning operation with a valid cleaning tape.

5 If a manual drive cleaning operation triggered this Diagnostic ticket,the cleaning cartridge used for the cleaning operation is invalid. Repeat the cleaning operation with a valid cleaning tape.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 401

Page 428: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR122 - Drive Tape Alert 22

This DR provides customer resolution steps for:

• DT122 on page 300

Problem: A tape drive determined that the cleaning media used for drive cleaning has expired.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 If a manual cleaning operation or host controlled cleaning operation has been performed, dismount the cleaning media from the tape drive and select a different cleaning cartridge to perform the drive cleaning operation. Export the expired cleaning media from the library and discard of the cartridge appropriately.

3 If an automatic, library-initiated drive cleaning operation caused this Diagnostic Ticket notification, consult the user documentation to export the expired cleaning media from the library; then import and configure a new cleaning media for automatic, library-initiated cleaning operations to continue uninterrupted cleaning operation when requested by a tape drive.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR123 - Drive Tape Alert 23

This DR provides customer resolution steps for:

• DT123 on page 301

• Problem: The tape drive determined that the cleaning media required for the requested drive cleaning operation is invalid. This Diagnostic Ticket is displayed when the drive expects a cleaning cartridge but the loaded cartridge is not a cleaning cartridge. The resolution of this issue depends on how the library or partition is configured to perform drive cleaning operations.

402 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 429: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 If the library is configured for library-initiated automatic drive cleaning, the cleaning process should have been triggered already when the tape drive recommended or required cleaning. However, since the tape drive is now indicating that it expects a valid cleaning tape, a valid, non-expired cleaning tape may not have been available or an incorrect cleaning cartridge may be configured:

a Check for any other cleaning related Diagnostic Tickets and verify that cleaning tapes are properly configured and not expired.

b Unload the current tape cartridge and perform a drive cleaning operation.

3 If the library is not configured for library-initiated automatic cleaning but the host application controls drive cleaning and has cleaning tapes configured within its partition, the host application may not have recognized that the drive required cleaning, or valid, non-expired cleaning tapes may not be available:

a Verify that the host application is properly configured to detect drive cleaning requests.

b Check for any other cleaning related Diagnostic Tickets and verify that cleaning tapes are properly configured and not expired.

c Unload the current tape cartridge and perform a drive cleaning operation.

4 If library-initiated automatic cleaning and host application controlled cleaning is not configured:

a Unload the currently mounted tape cartridge and perform a manual drive cleaning operation with a valid cleaning tape.

b Once the tape drive has been cleaned, reload the previously dismounted tape cartridge and restart the host application.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 403

Page 430: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 If a manual drive cleaning operation triggered this Diagnostic ticket, the cleaning cartridge used for the cleaning operation is invalid. Remove the tape cartridge and repeat the cleaning operation with a valid cleaning tape.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR130 - Drive Tape Alert 30

This DR provides customer resolution steps for:

• DT130 on page 302

Problem: A tape drive detected and reported a tape drive hardware fault which requires the drive to be reset.

1 Note the Diagnostic Ticket details to determine which tape drive reported the issue.

2 If the tape drive is mounted with a tape cartridge, attempt to unload such cartridge.

3 Consult the user documentation to initiate a drive reset operation.

4 Once the tape drive reinitialized, reload the tape cartridge if a tape cartridge was previously unloaded.

5 Restart any failed host application.

6 Monitor for reoccurrence. Contact Service for assistance if the issue is reported by the same tape drive again.

7 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

404 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 431: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR131 - Drive Tape Alert 31

This DR provides customer resolution steps for:

• DT131 on page 303

Problem: A tape drive detected and reported a tape drive hardware fault which requires the drive to be powered off and on again.

1 Note the Diagnostic Ticket details to determine which tape drive reported the issue.

2 Consult the user documentation to take the tape drive offline.

3 From the rear of the library, loosen the drive sled thumb screws of the tape drive and then pull the drive sled backwards to disconnect from the power connection without disconnecting any host interface cables.

4 Wait 30 seconds, then re-insert the drive sled and tighten the drive sled thumbs screws.

5 Once the tape drive reinitialized, restart any failed host application.

6 Monitor for reoccurrence. Contact Service for assistance if the issue is reported by the same tape drive again.

7 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR133 - Drive Tape Alert 33

This DR provides customer resolution steps for:

• DT133 on page 304

Problem: The tape drive determined and reported that the currently mounted tape cartridge needs to be ejected from the tape drive in order for the drive to recover from its fault condition.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Unload the tape cartridge from the tape drive; then export the tape cartridge from the library.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 405

Page 432: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Inspect the tape cartridge for any damage, such as a damaged shell, foreign material stuck to the cartridge, a snapped or disconnected tape.

4 If the tape cartridge appears good, import it back into the library, take the tape drive online again, mount the cartridge into the tape drive and retry the previously failing operation.

5 If the cartridge is defective, or if the problem remains unresolved, contact Service for assistance.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR136 - Drive Tape Alert 36

This DR provides customer resolution steps for:

• DT136 on page 305

Problem: The tape drive determined and reported that environmental conditions inside the tape drive are outside the specified temperature range. The drive sled's cooling fan may not be operating properly.

1 Note the Diagnostic Ticket details to determine which tape drive reported the issue.

2 Check if other tape drives within the library reported this Diagnostic Ticket.

3 If multiple tape drives reported this Diagnostic Ticket, verify that room temperatures are not above normal operating conditions.

4 Verify that the drive sled's fan is spinning and airflow through the drive sled is not blocked.

5 If no issue is found, contact Service for further assistance.

406 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 433: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR151 - Drive Tape Alert 51

This DR provides customer resolution steps for:

• DT151 on page 306

Problem: The tape drive detected and reported that the tape directory on the tape cartridge that was just unloaded has been corrupted. File search performance will be degraded.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Load the tape cartridge at an opportune time so the tape directory can be rebuilt.

3 Use the host application or a host utility to read all data from the tape cartridge. Reading all data on the tape cartridge will rebuild the tape directory and correct the corruption.

4 Monitor the tape cartridge for reoccurrence.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 407

Page 434: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR153 - Drive Tape Alert 53

This DR provides customer resolution steps for:

• DT153 on page 307

Problem: The tape drive detected and reported that the tape's system area could not be read successfully at load time.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Copy all required data from the faulty tape cartridge to another tape cartridge.

3 Discard the faulty tape cartridge when all required data has been copied.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR155 - Drive Tape Alert 55

This DR provides customer resolution steps for:

• DT155 on page 308

Problem: A tape drive did not load a cartridge. Automatic cartridge load retry attempts by the library were not successful and user intervention is required.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Select a different tape cartridge for a load operation to determine if the drive has an issue.

3 If the load operation with a different tape cartridge succeeds, export the failing tape cartridge from the library and inspect it for any damage. If damage is found, contact Service to determine how data can be copied to a replacement tape cartridge so the defective tape cartridge can be retired.

408 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 435: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 If the load operation with a different tape cartridge fails, contact Service for a possible tape drive replacement.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR156 - Drive Tape Alert 56

This DR provides customer resolution steps for:

• DT156 on page 309

Problem: A tape drive did not unload a cartridge correctly. Automatic unload recovery by the library was not successful and user intervention is required.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Retry the unload or move operation either via the host application that is currently using the drive, or via the remote or local user interface.

3 If the unload or move operation still fails, contact Service for further assistance.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 409

Page 436: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR158 - Drive Tape Alert 58

This DR provides customer resolution steps for:

• DT158 on page 310

Problem: The tape drive detected and reported a tape drive firmware problem. The drive automatically reset and recovered from the fault.

1 Note the Diagnostic Ticket details to determine which tape drive reported the issue.

2 Consult the user documentation to retrieve a tape drive log for problem analysis. Contact Service to have the tape drive log analyzed.

3 If the tape drive did not become functional, reset the tape drive again and continue operation. Monitor this issue for reoccurrence.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR159 - Drive Tape Alert 59

This DR provides customer resolution steps for:

• DT159 on page 311

Problem: The tape drive detected and reported an inconsistency during the WORM medium integrity checks.

1 Note the Diagnostic Ticket details to determine the specific tape cartridge and tape drive involved in the problem.

2 Copy the data from the WORM tape cartridge to another tape cartridge.

3 Discard the faulty WORM tape cartridge.

4 Monitor this issue for reoccurrence.

410 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 437: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR165 - Library Control Path Failover

This DR provides customer resolution steps for:

• DT165 on page 312

Problem: A library control path through a drive is no longer operational. The library control path switched successfully to a configured failover drive.

1 View the ticket details to determine which drive reported the issue.

2 Check whether other tickets have been generated for this drive.

3 If other tickets exist, resolve such tickets before continuing with this ticket resolution.

4 Verify that the host and any interconnect switches are operational and the fibre cable connection between the host and drive is properly connected.

5 Disconnect each fibre cable connection end point and inspect for defects such as breaks or cuts; re-connect or replace the fibre cable.

6 Close this ticket.

7 Consult the user documentation to initiate a drive reset operation, then reset the drive and observe drive initialization. If the drive initializes and no ticket is generated for the drive, the fibre channel link has been re-established and the data path to the drive is operational.

8 To validate whether the library control path can be hosted by the drive again if a failback/failover operation occurs again, consult the user documentation to force a control path failover operation via the Tools > Drive Operations menu selection to validate library control path functionality for configured drives, and perform such tests at an opportune and convenient time.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 411

Page 438: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

9 If the problem persists, contact Service for further assistance.

10 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR166 - Library Control Path Warning

This DR provides customer resolution steps for:

• DT166 on page 313

Problem: A redundant library control path drive did not establish a host connection. In the event of a control path failover need, a failover will not succeed.

1 View the ticket details to determine which drive reported the issue.

2 Check whether other tickets have been generated for this drive.

3 If other tickets exist, resolve such tickets before continuing with this ticket resolution.

4 Verify that the host and any interconnect switches are operational and the fibre cables between the host and drive are properly connected.

5 Disconnect each fibre cable connection end point and inspect for defects such as breaks or cuts; re- connect or replace the fibre cable.

6 Check that the drive sled interface port link light is lit.

7 Close this ticket.

8 Consult the user documentation to initiate a drive reset operation, then reset the drive and observe drive initialization. If the drive initializes and no ticket is generated for the drive, the fibre channel link has been re-established and the data path to the drive is operational.

412 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 439: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

9 To validate whether the library control path can be hosted by the drive again if a failback/failover operation occurs again, consult the user documentation to force a control path failover operation via the Tools > Drive Operations menu selection to validate library control path functionality for configured drives, and perform such tests at an opportune and convenient time.

10 If the problem persists, contact Service for further assistance.

11 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR167 - Library Control Path Failure

This DR provides customer resolution steps for:

• DR167 - Library Control Path Failure on page 413

Problem: A library control path drive lost its host connection and a control path failover was attempted, but a host connection could not be established via the redundant control path drive.

1 View the ticket details to determine which drives are configured for library control path connections.

2 Check whether other tickets have been generated for the affected drives.

3 If other tickets exist, resolve such tickets before continuing with ticket resolution.

4 Verify that the host and any interconnect switches are operational.

5 Verify that the fibre channel cables between the host, switch and drives are properly connected.

6 Disconnect each fibre cable connection end point and inspect for defects such as breaks or cuts; reconnect or replace any fibre cable if defects are found.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 413

Page 440: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

7 Upon fibre cable connection, observe the drive sled link status LED to determine if a link has been established. The LED turns green once a link is operational.

8 If a link cannot be established, close this ticket and consult the user documentation to initiate a drive reset operation, then reset the affected drive and observe drive initialization. If the drive initializes, the link status LED turns green, and no tickets are generated for the drives, the fibre channel links have been re-established and the control path to the library should be operational.

9 If the problem persists, contact Service for further assistance.

10 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR170 - EKM License Expiring

This DR provides customer resolution steps for:

DT170 on page 315

Problem: The library firmware detected that the number of encryption capable tape drives, which are configured in LME partitions, exceeds the number of tape drives that may be encryption enabled under the current encryption license. If the violation is not corrected within 120 days from the first instance of this ticket, the library firmware shall reconfigure all LME partitions/tape drives, to use AME encryption.

1 To prevent or correct disabling of LME capabilities, reconfigure partitions to allow LME configurations that are in line with the installed encryption license.

2 Alternatively, contact Service to purchase and install an encryption license which meets your current usage.

414 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 441: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR171 - EKM License Expired

This DR provides customer resolution steps for:

DT171 on page 316

Problem: The library firmware detected that the grace period for exceeding the current encryption license usage time has expired. The number of encryption capable tape drives configured in LME partitions exceeds the number allowed under the current encryption license. All LME capabilities have been disabled.

1 ) To enable partitions for LME again, reconfigure the partitions, observing the respective LME licensed drive count.

2 Alternatively, contact your customer service representative to purchase and install an encryption license which meets your current drive count and usage needs.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 415

Page 442: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR172 - EKM Primary Failover

This DR provides customer resolution steps for:

DT172 on page 317

Problem: The library is not able to communicate with its primary EKM server and successfully failed over to the secondary EKM server to continue operation. This does not indicate a problem with the library, but rather a primary EKM server connection or EKM server functionality issue.

1 Ensure that the primary EKM server is properly connected to the network, and that the network cable is not damaged.

2 Verify that the primary EKM server is powered on and operational.

3 Ensure that the library's IP address settings are correct, and that the Key Server IP and port configuration is configured appropriately.

4 If no problems are found with any of these items, then there is a configuration problem with your network. Contact your network administrator for assistance with troubleshooting this issue.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR173 - EKM Request Failure

This DR provides customer resolution steps for:

DT173 on page 318

Problem: The library is not able to successfully communicate with its connected EKM servers. This does not indicate a problem with the library, but rather indicates a network issue or EKM server configuration, setup or functionality issue.

1 Note the Diagnostic Ticket details to determine whether the issue is EKM server communication or configuration related.

416 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 443: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

2 If the issue is an EKM server configuration problem, a separate Diagnostic Ticket has been generated and requires resolution. Close this ticket and resolve the respective EKM server configuration ticket(s).

3 If the issue is a communication problem, perform the following steps:

a Ensure that the library is properly connected to the network, and that the network cable is not damaged.

b Ensure that the library's IP address settings are correct, and that the Key Server IP and port configuration is configured appropriately.

c Verify that the Key Server is powered on, operational, and properly connected to the network.

d Ensure that the Key Server's IP and port configuration is set properly and responding.

e If no problems are found with any of these items, then there is a configuration problem with your network. Contact your network administrator for assistance with troubleshooting this issue.

4 If the issue cannot be resolved, contact Service for further assistance.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 417

Page 444: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR174 - EKM Secondary Failover

This DR provides customer resolution steps for:

DT174 on page 319

Problem: The library is not able to communicate with its secondary EKM server and successfully failed back to the primary EKM server to continue operation. This does not indicate a problem with the library, but rather a secondary EKM server connection or EKM server functionality issue.

1 Ensure that the primary EKM server is properly connected to the network, and that the network cable is not damaged.

2 Verify that the primary EKM server is powered on and operational.

3 Ensure that the library's IP address settings are correct, and that the Key Server IP and port configuration is configured appropriately.

4 If no problems are found with any of these items, then there is a configuration problem with your network. Contact your network administrator for assistance with troubleshooting this issue.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR175 - EKM Communication Warning

This DR provides customer resolution steps for:

DT175 on page 320

Problem: During regular communication path testing, the library detected a problem when trying to connect to a Key Server. This does not indicate a problem with the library, but rather a configuration, setup or Key Server functionality issue.

1 Ensure that the library is properly connected to the network, and that the network cable is not damaged.

2 Verify that the Key Server is powered on, operational, and properly connected to the network.

418 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 445: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Ensure that the library's IP address settings are correct, and that the Key Server IP and port configuration is configured appropriately.

4 Ensure that the Key Server's IP and port configuration is set properly and responding.

5 If no problems are found with any of these items, then there is a configuration problem with your network. Contact your network administrator for assistance with troubleshooting this issue.

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR176 - EKM Mirror Warning

This DR provides customer resolution steps for:

DT176 on page 321

Problem: A Key Server reported that it detected a communication failure to the alternate Key Server, preventing data exchanges and data synchronization. No data is lost and resynchronization will resume once communication is re-established.

1 Verify that both Key Servers are powered on, operational, and properly connected to the network.

2 Ensure that both Key Servers are properly connected to the network to exchange and synchronize information.

3 Ensure that both Key Servers are configured with the respective IP address of the mirror Key Server and that the servers reference each other.

4 If no problems are found with any of these items, then there is a configuration problem with your network. Contact your network administrator for assistance with troubleshooting this issue.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 419

Page 446: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR177 - EKM Server Fault

This DR provides customer resolution steps for:

DT177 on page 322

Problem: A Key Server reported that it detected a server fault. The Key Server is still operational but requires attention. The nature of the issue is detailed in the Diagnostic Ticket details.

1 Note the issue description in the Diagnostic Ticket details.

2 If a temperature issue is reported, check your user documentation for proper room temperature range requirements and correct any possible adverse room temperature conditions. Make sure both hard disk drives are installed and air flow through the server is not obstructed. Contact Service if the issue persists.

3 If an EKM server application software failure is reported collect the EKM server logs via the remote user interface Tools > EKM Management > Retrieve SKM Logs menu selection and contact Service for assistance.

4 If a disk failure is reported, contact Service for a replacement of hard disk drive 0 or 1. Once a replacement disk has been received, consult your user documentation for the proper disk replacement procedure.

5 For all other failures, contact Service for a possible EKM server replacement. Once a new server has been received, consult your user documentation for the proper server and disk replacement and restore procedure.

420 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 447: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

6 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR178 - EKM Key Unknown

This DR provides customer resolution steps for:

DT178 on page 323

Problem: A Key Server reported that a requested encryption key is unknown to the Key Server. The Key Server is still operational but does not have the proper encryption key stored, usually due to a previously encrypted tape cartridge having been inserted into the library configuration without having the required encryption key imported too.

1 Note the cartridge barcode label information from the Diagnostic Ticket and determine in which library the tape cartridge was previously used and encrypted.

2 Consult your User Guide regarding export operations of encryption keys and export the required encryption key from the library configuration where the tape cartridge was encrypted.

3 Consult your User Guide regarding import operations of encryption keys and import the required encryption key to this library configuration.

4 Restart the host application that failed to retrieve data from the encrypted tape cartridge.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 421

Page 448: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR179 - EKM Key Set Depleted

This DR provides customer resolution steps for:

DT179 on page 324

Problem: The library detected that the encryption key usage exceeds 80% of the key set pre-generated for library managed encryption use. To continue uninterrupted operation and before all encryption keys have been exhausted, an additional set of keys should be generated and then backed up at the earliest convenience.

1 Schedule a key generation operation as soon as possible to prevent any interruption in encryption key requests.

2 Ensure both EKM servers are operational.

3 From the remote user interface, view the library partition configuration by selecting Setup > Encryption > Partition Configuration.

4 Select a logical library partition that is configured for library managed encryption and temporarily disable library managed encryption by selecting Allow Application Managed encryption.

5 Wait 3 minutes to allow the drives to reconfigure, and then re-enable the logical library partition for library managed encryption, which starts the process of encryption key generation on both EKM servers.

6 Once the logical library partition succeeds in enabling library managed encryption, a new set of encryption keys have been generated; consult your user documentation to perform EKM server backup operations on both EKM servers so that all encryption keys can be saved for safe-keeping and restored in the event of a catastrophic EKM server failure.

7 If the key generation process fails, make sure both key servers are functional and repeat the steps 2 to 6.

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

422 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 449: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR180 - EKM Software Mismatch

This DR provides customer resolution steps for:

DT180 on page 325

Problem: The library detected that the attached encryption key servers do not have the same software versions installed. A software version mismatch may limit functionality and may cause unexpected results.

1 Note the Ticket details for server IP addresses and firmware versions.

2 Consult your user documentation to perform a software update on the EKM server whose IP address is listed with the lower software version.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR181 - EKM Key Corrupted

This DR provides customer resolution steps for:

DT181 on page 326

Problem: The library detected corrupted encryption keys within the selected export/import file. An import operation will succeed, however, one or more encryption keys were not transferred to an EKM server.

1 Note the number of corrupted encryption keys from the Diagnostic Ticket details.

2 Select and view the Encryption Key Import Warning Log from the Reports >Log Viewer menu selection.

3 Determine if any of the listed corrupted encryption keys are required to continue operation.

4 If any of the identified corrupted encryption keys are needed, repeat an encryption key export operation on the library from which the encryption keys were exported; then import such encryption keys as needed.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 423

Page 450: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR182 - EKM Key Set Exhausted

This DR provides customer resolution steps for:

DT182 on page 327

Problem: The library detected that the encryption key usage on one or both of the EKM servers reached 100% of the key set pre-generated for library managed encryption use. Since all encryption keys have been used, a new set of keys must be generated to continue operation; if keys are still available on the alternate EKM server, the library is able to continue requesting new encryption keys, but an additional set of keys should be generated and then backed up at the earliest convenience.

1 Schedule key generation as soon as possible to continue uninterrupted encryption key requests.

2 Ensure both EKM servers are operational.

3 From the remote user interface, view the library partition configuration by selecting Setup > Encryption > Partition Configuration.

4 Select a logical library partition that is configured for library managed encryption and temporarily disable library managed encryption by selecting Allow Application Managed encryption.

5 Wait 3 minutes to allow the drives to reconfigure, then re-enable the logical library partition for library managed encryption, which starts the process of encryption key generation on both EKM servers.

6 Once the logical library partition succeeds in enabling library managed encryption, a new set of encryption keys have been generated; consult your user documentation to perform EKM server backup operations on both EKM servers so that all encryption keys can be saved for safe-keeping and restored in the event of a catastrophic EKM server failure.

424 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 451: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

7 If the key generation process fails, make sure both key servers are operational and repeat steps 2 to 6.

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR183 - EKM Key Set Missing

This DR provides customer resolution steps for:

DT183 on page 328

Problem: The library detected that a previously generated EKM server encryption key store is missing or incorrect. This may be the result of an EKM server replacement procedure which did not perform the necessary key store restore operation yet, or restored an older key store copy. The library cannot retrieve encryption keys from the attached EKM server until the required key store is restored.

1 Note the Diagnostic Ticket details to determine which EKM server is reporting an invalid encryption key store.

2 Locate the latest key store backup copy applicable to the EKM server.

3 Stop host application and library operations to prevent any encryption key requests.

4 Consult your user documentation to perform a restore operation of the key store for the respective EKM server.

5 Once a restore operation on the EKM server completes, consult your library user documentation to perform an EKM Path Diagnostic test for the respective EKM server.

6 If the EKM Path Diagnostic test succeeds, close the Diagnostic Ticket and restart host application and library operations.

7 ) If the Diagnostic Ticket re-occurs, or the EKM Path Diagnostic test fails, contact Service for further assistance.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 425

Page 452: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

8 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR184 - EKM Key Server Sync Warning

This DR provides customer resolution steps for:

DT184 on page 329

Problem: The library detected that a previously generated EKM server encryption key store is not properly synchronized with the library. This may be the result of an EKM server replacement and restore procedure that did not synchronize the library to the restored key store. The library cannot retrieve new encryption keys from the attached EKM server until the required synchronization procedure is performed on the library.

1 Stop host application and library operations to prevent any encryption key requests.

2 Disable library managed encryption on a single partition that is currently configured to perform library managed encryption.

3 Wait 3 minutes to allow the tape drives to reconfigure the encryption method change.

4 Re-enable library managed encryption on the partition that was just disabled.

5 Close the Diagnostic Ticket and restart host application and library operations.

6 If the Diagnostic Ticket re-occurs contact Service for further assistance.

426 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 453: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

7 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR185 - EKM Server HTTP Access

This DR provides customer resolution steps for:

DT185 on page 330

Problem: The library detected that the attached encryption key management server cannot be accessed via its http port 80, which prevents access to the server's serial number, firmware version, or server log information.

1 Note the server IP address from the ticket details and verify the http connectivity to the SKM server by pointing a browser to the EKM server IP address.

2 If the browser cannot attach to the EKM server, http access to the server seems to be blocked by the EKM server or switch/router.

3 If the browser can attach to the EKM server, make sure it is connected through the same switch/router connection that connects the library.

4 If the issue cannot be resolved, contact Service for further assistance.

5 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 427

Page 454: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR186- Resolve EKM Server Key Generation

This DR provides customer resolution steps for:

• DT186 on page 331

Problem: The library detected that the encryption key usage exceeded 80% of the pre-generated key set for library managed encryption use. An additional encryption key set has been generated successfully on the attached EKM servers and need to be backed up at the earliest convenience to prepare for possible disaster recovery.

1 Consult your user documentation to perform EKM server backup operations on both EKM servers so that all encryption keys can be saved for safe-keeping and restored in the event of a catastrophic EKM server failure.

2 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR187 - EKM Server Certificate Expiring

This DR provides customer resolution steps for:

DT186 on page 331

Problem: The library firmware detected that a certificate in support of secure EKM server communication is going to expire. Unless a new EKM server communication certificate is applied prior to expiration of the EKM server communication certificate, the library and EKM server will not be able to establish secure communication.

1 View the ticket details to determine on which EKM server the certificate is going to expire.

2 Consult the respective EKM server user guide for information as to how to apply new EKM server communication certificates.

3 Apply new EKM server communication certificates before the existing certificate(s) will expire to allow uninterrupted and continued EKM server communication.

428 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 455: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR188 - Library Certificate Expiring

This DR provides customer resolution steps for:

DT188 on page 333

Problem: The library firmware detected that a certificate in support of secure EKM server communication is going to expire. Unless a new library communication certificate is applied prior to expiration of the library communication certificate, the library and EKM server will not be able to establish secure communication.

1 View the ticket details to determine when the library communication certificate will be expiring.

2 Consult the library user guide for information as to how to apply new library communication certificates.

3 Apply new library communication certificates before the existing certificate(s) will expire to allow uninterrupted and continued secure EKM server communication.

4 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 429

Page 456: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR189 - Library Certificate Expired

This DR provides customer resolution steps for:

DT189 on page 334

Problem: The library firmware detected that a certificate in support of secure EKM server communication has expired. Unless a new library communication certificate is applied, the library and EKM server will not be able to establish secure communication.

1 Consult the library user guide for information as to how to apply new library communication certificates, then apply new library communication certificates to re-establish and continue secure EKM server communication.

2 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR 190 - Expiring AR License

This DR provides customer resolution steps for:

• DT190 on page 335

Problem: The library firmware detected that the temporary license in support of Advanced Reporting will be expiring in less than 30 days. Unless a permanent Advanced Reporting license is installed, the Advanced Reporting feature will be disabled at the expiration date listed in the ticket details.

1 Contact Service to purchase a permanent license to enable continuous, uninterrupted Advanced Reporting functionality.

2 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

430 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 457: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR 191 - Expired AR License

This DR provides customer resolution steps for:

• DT191 on page 336

Problem: The library firmware detected that the temporary license in support of Advanced Reporting has expired. The Advanced Reporting feature will be disabled and will no longer be selectable.

1 Contact Service to purchase a permanent license to enable continuous Advanced Reporting functionality.

2 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR 192 - Hitachi License Activation

This DR provides customer resolution steps for:

DT192 on page 337

Problem: The library firmware detected that Hitachi-specific library functionality has been enabled.

1 If the application of the Hitachi specific license was intentional, no further action is required. In this case, close the Diagnostic Ticket.

2 If the license was applied erroneously, leave this Diagnostic Ticket open and contact Service for assistance to remove the license.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 431

Page 458: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

DR 195 - Media Removal Notification

This DR provides customer resolution steps for:

DT195 on page 338

Problem: The library has been configured to inform of expected tape cartridge removal. Media removal is expected whenever an exported tape cartridge has been physically removed from an I/E area element.

1 No further action is required as the media removal was expected. I/E area elements may now be available again for operator initiated tape cartridge insert/import operations.

2 To view which tape cartridges have been removed, select the Media Security Log from the Reports > Log Viewer menu selection.

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

DR 196 - Media Security Warning

This DR provides customer resolution steps for:

DT196 on page 339

Problem: The library has been configured to inform of an unexpected tape cartridge removal. Media removal is not expected if a tape cartridge was previously detected in a storage, drive, or I/E element and is now no longer present within the library without having been properly exported/moved by the robot to a respective I/E area element for operator access and removal.

1 Tape cartridge removal authorization may need to be validated. The cartridge removal may have been the result of a manual bulk unload operation.

2 To view which tape cartridges have been removed, select the Media Security Log from the Reports > Log Viewer menu selection.

432 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 459: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

3 Choose from the following:

• Select Back to return to the previous resolution steps.

• Select Exit to skip issue resolution and leave the Diagnostic Ticket open for future diagnostic and troubleshooting reference.

• Select Close to indicate issue resolution and close the Diagnostic Ticket now.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 433

Page 460: Qauntum Scalar i40i80 i4 Maintenance Guide

Chapter 7: Diagnostic Tickets and ResolutionsDiagnostic Resolutions

434 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 461: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix ATape Alert Flag Descriptions

Tape Alert is an open industry standard that flags errors and provides possible solutions for storage devices and their media. This section provides information about Tape Alert flags, including the identifying number, severity, recommended message, and probable cause. explains the severity codes, and lists all the existing Tape Alert flags and their descriptions.

Support for specific Tape Alert flags may vary based on tape drive type and firmware revision. Not all tape drives support every Tape Alert. Consult your tape drive SCSI manual for more information.

For more information on Tape Alert, see http://www.t10.org/index.html for INCITS SCSI Stream Commands - 3 (SSC-3).

Tape Alert Flag Severity Codes

The following severity codes are used with Tape Alerts:

I Informational.

W Warning — The system may not be operating optimally. Continued operation without corrective action may cause a failure or raise critical Tape Alert flags.

C Critical — Either a failure has already occurred or a failure is imminent. Corrective action is required.

Quantum Scalar i40 and Scalar i80 Maintenance Guide 435

Page 462: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

Tape Drive Tape Alert Flag Descriptions

No. Flag Severity Recommended Application Client Message Probable Cause

1 Read warning W The tape drive is having problems reading data. No data has been lost, but there has been a reduction in the performance of the tape.

The drive is having severe trouble reading.

2 Write warning W The tape drive is having problems writing data. No data has been lost, but there has been a reduction in the capacity of the tape.

The drive is having severe trouble writing.

3 Hard error W The operation has stopped because an error has occurred while reading or writing data which the drive cannot correct.

The drive had a hard read or write error.

4 Media C Your data is at risk: 1 Copy any data you require from this

tape.2 Do not use this tape again.3 Restart the operation with a different

tape.

Media can no longer be written/read, or performance is severely degraded.

5 Read failure C The tape is damaged or the drive is faulty. Call the tape drive supplier help line.

The drive can no longer read data from the tape.

6 Write failure C The tape is from a faulty batch or the tape drive is faulty: 1 Use a good tape to test the drive. 2 If the problem persists, call the tape

drive supplier help line.

The drive can no longer write data to the tape.

436 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 463: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

7 Media life W The tape cartridge has reached the end of its calculated useful life: 1 Copy any data you need to another

tape. 2 Discard the old tape.

The media has exceeded its specified life.

8 Not data grade W The tape cartridge is not data-grade. Any data you write to the tape is at risk. Replace the cartridge with a data-grade tape.

The drive has not been able to read the MRS* stripes.

9 Write protect C You are trying to write to a write-protected cartridge. Remove the write-protection or use another tape.

Write command is attempted to a write- protected tape.

10 Media removal prevented

I You cannot eject the cartridge because the tape drive is in use. Wait until the operation is complete before ejecting the cartridge.

Manual or software unload attempted when prevent media removal on.

11 Cleaning media I The tape in the drive is a cleaning cartridge.

Cleaning tape loaded into drive.

12 Unsupported format

I You have tried to load a cartridge of a type which is not supported by this drive.

Attempted load of unsupported tape format.

13 Recoverable mechanical cartridge failure

C The operation has failed because the tape in the drive has experienced a mechanical failure: 1 Discard the old tape. 2 Restart the operation with a different

tape.

Tape snapped/cut or other cartridge mechanical failure in the drive where medium can be demounted.

No. Flag Severity Recommended Application Client Message Probable Cause

Quantum Scalar i40 and Scalar i80 Maintenance Guide 437

Page 464: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

14 Unrecoverable mechanical cartridge failure

C The operation has failed because the tape in the drive has experienced a mechanical failure: 1 Do not attempt to extract the tape

cartridge. 2 Call the tape drive supplier help line.

Tape snapped/cut or other cartridge mechanical failure in the drive where medium cannot be demounted.

15 Memory chip in cartridge failure

W The memory in the tape cartridge has failed, which reduces performance. Do not use the cartridge for further write operations.

Memory chip failed in cartridge.

16 Forced eject C The operation has failed because the tape cartridge was manually demounted while the tape drive was actively writing or reading.

Manual or forced eject while drive actively writing or reading.

17 Read-only format

W You have loaded a cartridge of a type that is read-only in this drive. The cartridge will appear as write protected.

Media loaded that is read-only format.

18 Tape directory corrupted on load

W The directory on the tape cartridge has been corrupted. File search performance will be degraded. The tape directory can be rebuilt by reading all the data on the cartridge.

Tape drive powered down with tape loaded, or permanent error prevented the tape directory being updated.

19 Nearing media life

I The tape cartridge is nearing the end of its calculated life. It is recommended that you: 1 Use another tape cartridge for your

next backup. 2 Store this tape cartridge in a safe

place in case you need to restore data from it.

Media may have exceeded its specified number of passes.

No. Flag Severity Recommended Application Client Message Probable Cause

438 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 465: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

20 Cleaning required

C The tape drive needs cleaning: 1 If the operation has stopped, eject

the tape and clean the drive.2 If the operation has not stopped,

wait for it to finish and then clean the drive.

Check the tape drive user’s manual for device-specific cleaning instructions.

The drive thinks it has a head clog or needs cleaning.

21 Cleaning requested

W The tape drive is due for routine cleaning: 1 Wait for the current operation to

finish. 2 Then use a cleaning cartridge. Check the tape drive user’s manual for device-specific cleaning instructions.

The drive is ready for a periodic cleaning.

22 Expired cleaning media

C The last cleaning cartridge used in the tape drive has worn out: 1 Discard the worn-out cleaning

cartridge. 2 Wait for the current operation to

finish. 3 Then use a new cleaning cartridge.

The cleaning tape has expired.

23 Invalid cleaning tape

C The last cleaning cartridge used in the tape drive was an invalid type: 1 Do not use this cleaning cartridge in

this drive. 2 Wait for the current operation to

finish.3 Then use a valid cleaning cartridge.

Invalid cleaning tape type used.

No. Flag Severity Recommended Application Client Message Probable Cause

Quantum Scalar i40 and Scalar i80 Maintenance Guide 439

Page 466: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

24 Retension requested

W The tape drive has requested a retension operation.

The drive is having severe trouble reading or writing, which will be resolved by a retension cycle.

25 Multi-port interface error on a primary port

W A redundant interface port on the tape drive has failed.

Failure of one interface port in a dual-port configuration (for example, Fibre Channel).

26 Cooling fan failure

W A tape drive cooling fan has failed. Fan failure inside tape drive mechanism or tape drive enclosure.

27 Power supply failure

W A redundant power supply has failed inside the tape drive enclosure. Check the enclosure user’s manual for instructions on replacing the failed power supply.

Redundant power supply unit failure inside the tape drive enclosure or rack subsystem.

28 Power consumption

W The tape drive power consumption is outside the specified range.

Power consumption of the tape drive is outside specified range.

29 Drive preventive maintenance required

W Preventive maintenance of the tape drive is required. Check the tape drive user’s manual for device-specific preventive maintenance tasks or call the tape drive supplier help line.

The drive requires preventative maintenance (not cleaning).

30 Hardware A C The tape drive has a hardware fault: 1 Eject the tape or magazine. 2 Reset the drive. 3 Restart the operation.

The drive has a hardware fault that requires reset to recover.

No. Flag Severity Recommended Application Client Message Probable Cause

440 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 467: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

31 Hardware B C The tape drive has a hardware fault: 1 Turn the tape drive off and then on

again.2 Restart the operation. 3 If the problem persists, call the tape

drive supplier help line.

The drive has a hardware fault that is not read/write related or requires a power cycle to recover.

32 Primary interface

W The tape drive has a problem with the host interface: 1 Check the cables and cable

connections. 2 Restart the operation.

The drive has identified an interface fault.

33 Eject media C The operation has failed: 1 Eject the tape or magazine. 2 Insert the tape or magazine again. 3 Restart the operation.

Error recovery action.

34 Microcode update fail

W The microcode update has failed because you have tried to use the incorrect microcode for this tape drive. Obtain the correct microcode and try again.

Microcode update failed.

35 Drive humidity W Environmental conditions inside the tape drive are outside the specified humidity range.

Drive humidity limits exceeded.

36 Drive temperature

W Environmental conditions inside the tape drive are outside the specified temperature range.

Cooling problem.

37 Drive voltage W The voltage supply to the tape drive is outside the specified range.

Drive voltage limits exceeded.

38 Predictive failure

C A hardware failure of the tape drive is predicted. Call the tape drive supplier help line.

Predictive failure of drive hardware.

No. Flag Severity Recommended Application Client Message Probable Cause

Quantum Scalar i40 and Scalar i80 Maintenance Guide 441

Page 468: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

39 Diagnostics required

W The tape drive may have a hardware fault. Run extended diagnostics to verify and diagnose the problem. Check the tape drive user’s manual for device-specific instructions on running extended diagnostic tests.

The drive may have a hardware fault that may be identified by extended diagnostics (i.e., SEND DIAGNOSTIC command).

40 – 46

Obsolete

47 – 49

Reserved

50 Lost statistics W Media statistics have been lost at some time in the past.

Drive or library powered down with tape loaded.

51 Tape directory invalid at unload

W The tape directory on the tape cartridge just unloaded has been corrupted. File search performance will be degraded. The tape directory can be rebuilt by reading all the data.

Error prevented the tape directory being updated on unload.

52 Tape system area write failure

C The tape just unloaded could not write its system area successfully: 1 Copy data to another tape cartridge.2 Discard the old cartridge.

Write errors while writing the system area on unload.

53 Tape system area read failure

C The tape system area could not be read successfully at load time: 1 Copy data to another tape cartridge.

Read errors while reading the system area on load.

No. Flag Severity Recommended Application Client Message Probable Cause

442 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 469: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

54 No start of data C The start of data could not be found on the tape: 1 Check that you are using the correct

format tape. 2 Discard the tape or return the tape to

your supplier.

Tape damaged, bulk erased, or incorrect format.

55 Loading or threading failure

C The operation has failed because the media cannot be loaded and threaded:1 Remove the cartridge, inspect it as

specified in the product manual, and retry the operation.

2 If the problem persists, call the tape drive supplier help line.

The drive is unable to load the media and thread the tape.

56 Unrecoverable unload failure

C The operation has failed because the medium cannot be unloaded:1 Do not attempt to extract the tape

cartridge.2 Call the tape driver supplier help line.

The drive is unable to unload the medium.

57 Automation interface failure

C The tape drive has a problem with the automation interface:1 Check the power to the automation

system.2 Check the cables and cable

connections.3 Call the supplier help line if problem

persists.

The drive has identified an interface fault.

58 Microcode failure

W The tape drive has reset itself due to a detected microcode fault. If problem persists, call the supplier help line.

Microcode bug.

59 WORM medium — integrity check failed

W The tape drive has detected an inconsistency during the WORM medium integrity checks. Someone may have tampered with the cartridge.

Someone has tampered with the WORM medium.

No. Flag Severity Recommended Application Client Message Probable Cause

Quantum Scalar i40 and Scalar i80 Maintenance Guide 443

Page 470: Qauntum Scalar i40i80 i4 Maintenance Guide

Appendix A: Tape Alert Flag Descriptions

60 WORM medium — overwrite attempted

W An attempt had been made to overwrite user data on a WORM medium:1 If a WORM medium was used

inadvertently, replace it with a normal data medium.

2 If a WORM medium was used intentionally: a) Check that the software application is compatible with the WORM medium format you are using. b) Check that the medium is bar-coded correctly for WORM.

The application software does not recognize the medium as WORM.

61 – 64

Reserved

* Media Recognition System (MRS) is a method where pre-defined stripes are placed at the beginning of the media to identify the media. The MRS stripes are read to determine if the media is of data-grade. Data-grade media should be used in SCSI streaming devices since it is of the required quality and consistency to be used to store data (i.e., audio/video grade media should not be used).

No. Flag Severity Recommended Application Client Message Probable Cause

444 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 471: Qauntum Scalar i40i80 i4 Maintenance Guide

Index

A

About Library 182

admin password, resetting 13

advanced reporting 199

all slots report 192

automatic EKM path diagnostics 222

B

bezel, library, replacing 102

C

cabling the library 77

carriage release button 61, 62

chassis, removing and replacing 107

cleaning log 193

configurationrecord 188report 186

restoring 33saving 33

contact informationQuantum xxiii

D

defaults, resetting factory 219

desktop kitinstalling library in 93removing library from 101removing top cover 55

diagnostic ticketslog 194viewing, closing, and resolving

227

diagnostics 216EKM path 220resetting a tape drive 217robotics get/put 218

downgrading library firmware 34

E

EKM

path diagnosticsabout 220automatic 222manual 222

emergency power-off procedure 20

ESD precautions 76

F

factory defaults, resetting 219

filler platepower supply, removing and

installing 119tape drive, removing and

installing 119

firmwarelibrary, downgrading 34

G

get/put test 218

Quantum Scalar i40 and Scalar i80 Maintenance Guide 445

Page 472: Qauntum Scalar i40i80 i4 Maintenance Guide

Index

I

I/E station, unlocking 25

installation and verification test 211

IP address, service port 3IVT 211

L

LEDs 206front panel 206power supply 210system control board 207tape drive/sled 208

library configurationrecord 188report 186saving 33

library not ready messages 203

licensesreport 198

lodged tape removal 43

logged in user’s report 191

logging in with service privileges 5logging out 12

logscleaning 193diagnostic tickets 194SKM encryption key import

warning log 194tape drive 195, 205

M

magazine bezel plug 54

magazinesreleasing 28removing and replacing 121test 213unlocking 28

manual EKM path diagnostics 222

menu trees, service 6move test 215

moving the library 143

N

network settingsreport 190, 198

not ready messages 203

O

online/offlinelibrary 21partitions 21tape drives 23

operator panelhome screen, changing view 9

P

packaging the library 143

partitionsreports 197taking online/offline 21

passwordadmin, resetting 13service 5

path diagnostics, EKM 220automatic 222manual 222

pickermoving along X-axis 63, 64moving along Z-axis 60swiveling on theta axis 65

picker fingers, rotating 45

plug, library thumbscrew 54

power supply, removing and

installing 126

power-off, emergency 20

R

rackinstalling library in 90removing library from 92

rack mount kit, installing 79

rail kit 79

random move test 215

releasingmagazines 28robot 37

remote service login, enabling 11

removing power 14, 20

reportsabout 182advanced reporting 199all slots 192date/time 198library configuration 186licenses 198logged in users 191network settings 190, 198operator panel 197partition 197system information 182tape drives 197

resettingadmin password 13factory defaults 219tape drive 217

restart 14, 17

restoring the library configuration 33

robotget/put test 218releasing at install 37replacement 149restraint

installing 37

446 Quantum Scalar i40 and Scalar i80 Maintenance Guide

Page 473: Qauntum Scalar i40i80 i4 Maintenance Guide

Index

removing 37robotics test 213

S

saving the library configuration 33

servicelogin, remote 11menus 6password 5port

configuring 31connecting to 3IP address 3

user name 5shipping the library 143

shut down 14, 15

SKMencryption key import warning

log 194logs 194

stuck tape procedure 43

system control boardremoving and replacing 129

system information report 182

T

tape cartridgelodged 43stuck 43

tape cartridgesmap, creating 121

tape driveslog 195online/offline 23pulling out 44removing 44, 49removing and replacing 137removing with lodged

cartridge 44reports 197

resetting 217test 213unloading, manual 68

LTO-4 full height 70LTO-4 half height 68

TapeAlerts 435

testsinstallation and verification

(IVT) 211magazine 213random move 215robotics 213robotics get/put 218tape drive 213

theta gear 66

thumbscrew plug 54

top cover, removing 52, 55

troubleshooting 201

turning off 14, 19

U

unlockingI/E station 25magazines 28

user name, service 5

Quantum Scalar i40 and Scalar i80 Maintenance Guide 447

Page 474: Qauntum Scalar i40i80 i4 Maintenance Guide

Index

448 Quantum Scalar i40 and Scalar i80 Maintenance Guide