8
OPTIFLUX 2000/4000/5000 Electromagnetic Flow Sensor Flanged versions for volumetric flow rate measurement of electrically conductive liquids General Items supplied For in-depth information please consult the handbook, data sheet, special manuals and certificates supplied on CD- ROM. Installation, assembly, commissioning and servicing must only be undertaken by trained personnel. Maintenance which is considered relevant to safety in the sense of explosion protection must only be carried out by the manufacturer, his agents or under the supervision of experts. Visual check Example For use in hazardous areas, special codes and regulations are applicable, which are supplied in a separate document that describes all hazardous area relevant information. Responsibility as to suitability and intended use of this device rests solely with the user. The supplier does not accept any liability resulting from misuse by the customer. Improper installation and operation may lead to loss of warranty. In addition, the "General conditions of sale", found on the back of the invoice and forming the basis of the purchasing contract, are applicable. If you need to return the device to the manufacturer or supplier, please complete the form given on the CD-ROM and attach it to the device. KROHNE regrets that it cannot repair or check your device unless accompanied by this completed form. only separate version JS © KROHNE 09/2006 7.30946.33.00 Liner materials Electrode materials PFA PFA HC4 Hastelloy C4 PTFE PTFE HB2 Hastelloy B2 PU Polyurethane Pt Platinum CER Ceramic 316 Stainless steel ETFE ETFE Ta Tantalum PP Polypropylene Ti Titanium HR Hardrubber HC4/LN LowNoise HC4 316Ti / LowNoise, stainless steel LN 1.4571 Quick Start

QS_OPTIFLUX2000_e_7309463300_060908

  • Upload
    magolel

  • View
    212

  • Download
    0

Embed Size (px)

DESCRIPTION

n

Citation preview

  • OPTIFLUX 2000/4000/5000 Electromagnetic Flow Sensor

    Flanged versions for volumetric flow rate measurement

    of electrically conductive liquids

    General Items supplied

    For in-depth information please consult the handbook, data sheet, special manuals and certificates supplied on CD-ROM.

    Installation, assembly, commissioning and servicing must only be undertaken by trained personnel. Maintenance which is considered relevant to safety in the sense of explosion protection must only be carried out by the manufacturer, his agents or under the supervision of experts.

    Visual check

    Example

    For use in hazardous areas, special codes and regulations are applicable, which are supplied in a separate document that describes all hazardous area relevant information.

    Responsibility as to suitability and intended use of this device rests solely with the user. The supplier does not accept any liability resulting from misuse by the customer. Improper installation and operation may lead to loss of warranty. In addition, the "General conditions of sale", found on the back of the invoice and forming the basis of the purchasing contract, are applicable.

    If you need to return the device to the manufacturer or supplier, please complete the form given on the CD-ROM and attach it to the device. KROHNE regrets that it cannot repair or check your device unless accompanied by this completed form.

    only separate version

    JS

    KROHNE 09/2006 7.30946.33.00

    Liner materials Electrode materials PFA PFA HC4 Hastelloy C4 PTFE PTFE HB2 Hastelloy B2 PU Polyurethane Pt Platinum CER Ceramic 316 Stainless steel ETFE ETFE Ta Tantalum PP Polypropylene Ti Titanium HR Hardrubber HC4/LN LowNoise HC4 316Ti / LowNoise, stainless steel LN 1.4571

    Quick Start

  • Quick Start OPTIFLUX 2000/4000/5000 2

    OPTIFLUX 2000/4000/5000

    Handling and installation instructions

    min. 5 DN min. 2 DN

    L max. L min. 0.5 mm L max.

    L min.

  • 3 Quick Start OPTIFLUX 2000/4000/5000

    OPTIFLUX 2000/4000/5000

    Handling and installation instructions

    C F

    min. max. with min. max. min. max. with min. max.IFC 300 -40C 140C IFC 300 -40F 284FIFC 010 -25C 120C IFC 010 -13F 248FIFC 300 -40C 120C IFC 300 -40F 248FIFC 010 -25C 120C IFC 010 -13F 248FIFC 300 IFC 300IFC 010 IFC 010IFC 300 IFC 300IFC 010 IFC 010IFC 300 -40C 120C IFC 300 -40F 248FIFC 010 -25C 120C IFC 010 -13F 248FIFC 300 IFC 300IFC 010 IFC 010

    C min. max. F min. max.IFC 300 -40C 65C IFC 300 -40F 149FIFC 010 -25C 60C IFC 010 -13F 140F

    Ambient temperatures

    ETFE -40F 248F

    Polyurethane

    Polypropylene 23F 194F

    149F

    23F

    Liner Liner

    -5C

    Separate

    Hardrubber 23F 176F

    Compact

    PTFE / PFA -40F 356F

    90C

    Separate Compact

    -40C 180C

    120C

    80C

    65C

    120C

    -40C

    Polyurethane

    Ceramics

    Polypropylene

    Process temperatures

    PTFE / PFA

    ETFE

    Hardrubber

    -5C

    -60C

    -5C 194F

    23F 149F

    Ceramics -76F 248F

    23F 176F

    23F

    Ambient temperatures

    -5C 80C

    -5C 65C

    -5C 90C

    Note: The min. / max. temperatures for the compact devices are dependent on the liner / converter combination. See data sheet on CD-ROM.

    Avoid strong vibrations

    Process temperature

    Ambient temperature

  • Quick Start OPTIFLUX 2000/4000/5000 4

    OPTIFLUX 2000/4000/5000

    Special considerations

    min. 5 DN min. 2 DN

    10 DN

    5 m

  • 5 Quick Start OPTIFLUX 2000/4000/5000

    OPTIFLUX 2000/4000/5000

    Grounding Metal pipelines, not internally coated. Grounding without grounding rings.

    Metal pipelines, with internal coating, and internally non-conductive pipelines. Grounding with grounding rings.

    Grounding rings

  • Quick Start OPTIFLUX 2000/4000/5000 6

    OPTIFLUX 2000/4000/5000

    Torques and pressure OPTIFLUX 2000/4000: all liners

    PFA, PTFE, ETFE

    Polyurethane, hardrubber

    PFA,PTFE, ETFE

    Polyurethane, hardrubber

    2,5 PN 40 4 M 12 32 - 1/10 150 4 1/2" 32 -4 PN 40 4 M 12 32 - 1/6 150 4 1/2" 32 -6 PN 40 4 M 12 32 - 1/4 150 4 1/2" 32 -

    10 PN 40 4 M 12 7,6 4,6 3/8 150 4 1/2" 3,5 3,615 PN 40 4 M 12 9,3 5,7 1/2 150 4 1/2" 3,5 3,620 PN 40 4 M 12 16 9,6 3/4 150 4 1/2" 4,8 4,825 PN 40 4 M 12 22 11 1 150 4 1/2" 6,7 4,432 PN 40 4 M 16 37 1940 PN 40 4 M 16 43 25 1 1/2 150 4 1/2" 13 1250 PN 40 4 M 16 55 31 2 150 4 5/8" 24 2365 PN 16 4 M 16 51 4265 PN 40 8 M 16 38 2180 PN 10 8 M 16 47 25 3 150 4 5/8" 43 39

    100 PN 16 8 M 16 39 30 4 150 8 5/8" 34 31125 PN 16 8 M 16 53 40150 PN 16 8 M 20 68 47 6 150 8 3/4" 61 51200 PN 10 8 M 20 84 68 8 150 8 3/4" 86 69200 PN 16 12 M 20 68 45250 PN 10 12 M 20 78 65 10 150 12 7/8" 97 79250 PN 16 12 M 24 116 78300 PN 10 12 M 20 88 76 12 150 12 7/8" 119 104300 PN 16 12 M 24 144 105350 PN 10 16 M 20 97 75 14 150 12 1" 133 93400 PN 10 16 M 24 139 104 16 150 16 1" 130 91450 PN 10 20 M 24 127 93 18 150 16 1 1/8" 199 143500 PN 10 20 M 24 149 107 20 150 20 1 1/8" 182 127600 PN 10 20 M 27 205 138 24 150 20 1 1/4" 265 180700 PN 10 20 M 27 238 163 28 150 28 1 1/4" 242 161800 PN 10 24 M 30 328 219 32 150 28 1 1/2" 380 259900 PN 10 28 M 30 - 205 36 150 32 1 1/2" - 269

    1000 PN 10 28 M 35 - 261 40 150 36 1 1/2" - 269

    Note:DN 2,5 / 4 / 6 / 10 have a DN 15 flange.ANSI 1/10", 1/6", 1/4", 3/8" have a 1/2" flange.

    max. torqueNm

    Nominal size inch

    Flange class lb

    BoltsNominal size DN mm

    Pressure rating

    Bolts max. torque Nm

    Limits/Vacuum load For general limits see instrument type plate! Vacuum load only for PTFE and ETFE (Tefzel) lined flowmeters; see manual on CD-ROM for detailed information.

  • 7 Quick Start OPTIFLUX 2000/4000/5000

    OPTIFLUX 2000/4000/5000

    OPTIFLUX 5000: DN15100

    15 PN 40 4 M 12 73,5 1/2 150 4 1/2" 54,225 PN 40 4 M 12 73,5 1 150 4 1/2" 54,240 PN 40 4 M 16 178 1 1/2 150 4 1/2" 131,350 PN 40 4 M 16 178 2 150 4 5/8" 131,380 PN 40 4 M 16 178 3 150 4 5/8" 131,3

    100 PN 16 4 M 16 178 4 150 4 5/8" 131,3

    Nominal size

    Pressure rating

    Bolts max. torque Nm

    max. torqueftlb

    Nominal size inch

    Flange class

    lb

    Bolts

    Please use Stainless steel A2 / 6.9 class bolts Tighten the bolts in fixed order: 1+2 (in), 3+4 (out), 5+6 (in), 7+8 (out). See picture.

    Max. torque: Step 1: by hand Step 2: approx. 25% of max. torque Step 3: approx. 50% of max. torque Step 4: approx. 80% of max. torque Step 5: 100% of max. torque given in tables above.

    Gaskets: With the instrument, 4 PTFE gaskets are delivered (2 to be used with installation, 2 as spare or to be used when grounding rings are used). No other gaskets are required.

    OPTIFLUX 5000: DN150250

    150 PN 16 8 M 20 148 1/2 150 8 3/4" 109200 PN 10 8 M 20 183 1 150 8 3/4" 135250 PN 10 12 M 20 158 1 1/2 150 12 7/8" 117

    max. torqueftlb

    Nominal size inch

    Flange class

    lb

    BoltsNominal size

    Pressure rating

    Bolts max. torque Nm

    For ASME pipe flanges the max. allowable operating pressure is dependent on the process temperature, see Technical Data on CD-ROM. Material of joints: viton

    Max. torque: Step 1: approx. 50% of max. torque Step 2: approx. 80% of max. torque Step 3: 100% of max. torque given in tables above.