20
Quartz Scanner for Qweak Jeff Martin University of Winnipeg

Quartz Scanner for Qweak Jeff Martin University of Winnipeg

Embed Size (px)

Citation preview

Quartz Scanner for Qweak

Jeff Martin

University of Winnipeg

Motivation

• Q2 determination, background studies, all done at 10 nA using tracking system.

• Region III operable up to 100 nA.

• Qweak production running 180 A.

• Need a way to extrapolate over 3 orders of magnitude.

Proposal• Construct a scanning detector with small

active area to sense high-energy electrons and operable at any beam current.

• Similar technique used in E158 and HAPPEx.

• For E158, it was used to determine optics parameters, confirm Monte Carlo predictions of rates.

E158 Scanners

• 4 scanners

• radial and azimuthal motion

beam’s eye view

E158 Scanner Impact

ep

ee

validation of MC results and hence dilutions

from first E158 PRL

Principle of E158 Scanner

• For E158, PMT operated in current mode.

PMTquartz

pre-radscattered beam

Č

E158 as-built

19 mm tube

Qweak Scanner

• Always operate in pulse-counting mode, use 2” tubes.• Coincidence requirement to reduce background from light

guides.• V-shape to fit in Qweak

2” air-core light guide

PMT

quartz

scattered beam

pre-rad

PMT Č Č

Implementation in Qweak

• 2D motion assy scans over surface of Č-bar• Mount on Region III rotating support

structure in unused octant.

Implementation in Qweak

Implementation in Qweak

Implementation in Qweak

Implementation in Qweak

Implementation in Qweak

• Expected rates at 180 A

• Max rate = 1 MHzcourtesyJ. Mammei

Procedure• Measure light distribution with scanner at

low beam current acceptable to region III and Cherenkov bar coincidence.

• Measure light distribution with scanner at 180 uA.

• If they are the same, region III/Cherenkov light distribution believable at 180 uA to high confidence.– Note: scanner light map will not be the same as

the region III/Cherenkov bar coincidence map.

Additional Uses of a Scanner Detector

• Scan over large fiducial region, into inelastic region, over Cherenkov bar light guides, to get additional confidence in backgrounds.

• “Light map” can be compared to simulation.• Q2 extrapolation/determination

– mini-torus setting during production running?– gas vs. liquid target extrapolation?– at least, complementary to region III.

light yield simulation

quartz, 1 cm thickair-corelightpipe

30 p.e. per tube with no preradiator.Order of magnitude agreement with E158 simulations

Plan• Conduct light yield simulations.

• Benchmark with lab tests.

• Work on implementation in Qweak.

• Proposal to NSERC due Oct. 25, 2005, comments received from Davis, Mack, Pitt, Page, van Oers. Funding decision April 1, 2006.

• Simultaneous proposal to CFI for detector lab infrastructure at UWinnipeg.