28
FINANCE, RISK & BUSINESS PLANNING GROUP Supply Management City of Vancouver, Finance, Risk & Business Planning Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca INVITATION TO TENDER (“ITT”) NO. PS20150507 CONSTRUCTION OF BAY SEPARATION - FIREHALLS 19 AND 22 QUESTIONS AND ANSWERS NO. 3 ISSUED ON June 26, 2015 Q1 What is the selected finish for the storefronts and Auto Sliders? A1 Clear Anodized Aluminum. Q2 What is the extent of Laminated Glazing and Float Glazing? A2 All laminated. Q3 Is the Auto Slider only activated by a stand-alone Push Buttons or is it to be tied-in to an existing system? A3 Stand alone. Q4 Are there any locking requirements for the Auto Sliders? A4 Not required. Q5 Do the Auto Sliders require Break away action? A5 Yes in the event of power failure the doors must open for an emergency. Q6 Could you please forward this to the architect for approval as an alternate? See attached (27 pages). A7 The architect does not have any issues with the alternate glazing manufacturer so it can be approved an alternate.

QUESTIONS AND ANSWERS NO. 3 - Bidding Opportunitiesbids.vancouver.ca/bidopp/ITT/documents/PS20150507-QA3.pdf · 450 s/g Flush Glazed System Wind Load B2 ... extruded sub sill runner

Embed Size (px)

Citation preview

FINANCE, RISK & BUSINESS PLANNING GROUP

Supply Management

City of Vancouver, Finance, Risk & Business Planning Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca

INVITATION TO TENDER (“ITT”) NO. PS20150507

CONSTRUCTION OF BAY SEPARATION - FIREHALLS 19 AND 22

QUESTIONS AND ANSWERS NO. 3

ISSUED ON June 26, 2015

Q1 What is the selected finish for the storefronts and Auto Sliders?

A1 Clear Anodized Aluminum.

Q2 What is the extent of Laminated Glazing and Float Glazing?

A2 All laminated.

Q3 Is the Auto Slider only activated by a stand-alone Push Buttons or is it to be tied-in to an existing system?

A3 Stand alone.

Q4 Are there any locking requirements for the Auto Sliders?

A4 Not required.

Q5 Do the Auto Sliders require Break away action?

A5 Yes in the event of power failure the doors must open for an emergency.

Q6 Could you please forward this to the architect for approval as an alternate? See attached (27 pages).

A7 The architect does not have any issues with the alternate glazing manufacturer so it can be approved an alternate.

STANDARD ALUMINUM PRODUCTS INC.

Section B IndexStorefront Framing Systems

450 s/g Flush Glazed System Specification B1450 s/g Flush Glazed System Wind Load B2450 s/g Flush Glazed System Profiles B3-B8

550 d/g Flush Glazed System Specification B9550 d/g Flush Glazed System Wind Load B10550 d/g Flush Glazed System Profiles B11-B16

550T d/g Thermally Broken Flush Glazed System Specification B17550T d/g Thermally Broken Flush Glazed System Wind Load B18550T d/g Thermally Broken Flush Glazed System Profiles B19-B24

Sash & Stop B24Adjustable Base B24U Channels B25Miscellaneous Tubing B26

STANDARD ALUMINUM PRODUCTS INC.

Specification450 Series Flushed Glazed

Design

The system shall be 4 ½” x 1 ¾” center line

flush glazing and accommodate glass from

3mm to 10mm thick. The system can be

glazed from interior or exterior and is dry

glaze.

Performance

See Wind load Charts.

Structural performance shall conform to CSA

Standard CAN3-S157 “Strength design in

Aluminum” and a maximum deflection of 1/175

of the span.

Material

Extrusions shall be 6063 alloy and T5 Temper.

Glazing gaskets shall be EPDM elastomeric

extrusions.

Finish

Both anodized and painted finishes are

available. All integral colour anodizing is

Architectural Class II., 0.4 to 0.7 mm coating.

A fluropolymer paint coating conforming to the

requirements of AAMA 603 and AAMA 605

specifications, the toughest coating in the

industry standards.

Testing

All testing shall be on full size frame sections.

Air infiltration shall be tested in accordance

with ASTM-Designation E283-91 or ASHRAE

standards #90-80

Fabrication

Framing should be fabricated from extrusions

of size and shape in accordance with shop

drawings. The framing system shall provide

for flush glazing while maintaining the 1

¾” nominal face dimensions.

The 450 Series has a complete number of

sections including deflection header and

extruded sub sill runner that can satisfy any

design requirements.

Construction

Frames shall have mechanically joined

corners with no exposed screws. All joints

shall be accurately fitted free of burrs and

rough edges. Complete frame assemblies

shall be free of warp. Each type of entrance

framing systems is compatible with all

Standard Aluminum swing doors and sliding

mall fronts.

Installation

Experienced technicians in accordance with

approved shop drawings shall install all

frames. The frames shall be set plumb,

square, and level and in correct alignment and

adjacent construction. All anchoring shall suit

the type of construction of the perimeter work.

Protection and Cleaning

After installation the general contractor should

adequately protect the exposed aluminum and

glass surfaces from damage by other trades.

i.e.(but not restricted to) cement splash and

leach, grinding, polishing compounds, plaster,

paint, lime, acids and other contaminants.

STANDARD ALUMINUM PRODUCTS INC.

Wind Loads450 Series Flushed Glazed

SCALE 1/2 FULL SIZE

Calculations are based on CAN3-S157-M83 "Strength Design In Aluminum" using

6063-T5 Alloy-Temper, and a Deflection Limit = Span/175

2

5

6

7

8

9

10

11

12

13

14

15

3 4 5 6 7

Height (Feet)

Module Width, (Feet)

25 PSF

15 PSF

30 PSF

35 PSF

20 PSF

450 Series Storefront

2

7

8

9

10

11

12

13

14

15

16

18

3 4 5 6 8

Height (Feet)

Module Width, (Feet)

25 PSF

15 PSF

30 PSF

35 PSF

20 PSF

450 Series Storefront - Reinforced

7

17

STANDARD ALUMINUM PRODUCTS INC.

450 Series Flushed Glazed

4 1

/2

"

1 3/4"

Storefront System

11

4m

m

45mm45mm

1 3/4"

SCALE 1/2 FULL SIZE

450

45

0

45

1

STANDARD ALUMINUM PRODUCTS INC.

1 3

/4

"

4 1/2"

Storefront System450 Series Flushed Glazed

45

mm

114mm

SCALE 1/2 FULL SIZE

450

455

454

454

453

S553

450

458

Storefront System450 Series Flushed Glazed

11

4m

m

2

1

/

4

"

SCALE 1/2 FULL SIZE

451

451

559

STANDARD ALUMINUM PRODUCTS INC.

4 1/2"

4 1

/2

"

4 1

/2

"

114mm

11

4m

m

557

558

459

STANDARD ALUMINUM PRODUCTS INC.

450 SeriesSteel Reinforcing

19mm

3/4"

4"

10

1m

m

45mm

1 3/4"

SCALE 1/2 FULL SIZE

45

1

45

0

4 1

/2

"

11

4m

m

1 3/4"

45mm

45mm

450 Series Flushed GlazedStorefront System

STANDARD ALUMINUM PRODUCTS INC.

SCALE 1/2 FULL SIZE

456

456

45

1

45

0

1 3/4"

450

STANDARD ALUMINUM PRODUCTS INC.

1 3

/4

"

4 1/2"

450 Series Flushed GlazedStorefront System

114mm

45

mm

SCALE 1/2 FULL SIZE

450

454

455

550 Series Flushed GlazedSpecification

STANDARD ALUMINUM PRODUCTS INC.

SCALE 1/2 FULL SIZE

Design

The system shall be 4 ½” x 2” center line flush

glazing and accommodate glass from 22mm to

25mm thick. The system can be glazed from

interior or exterior and is dry glaze.

Performance

See Wind load Charts.

Structural performance shall conform to CSA

Standard CAN3-S157 “Strength design in

Aluminum” and a maximum deflection of 1/175 of

the span.

Material

Extrusions shall be 6063 alloy and T5 Temper.

Glazing gaskets shall be EPDM elastomeric

extrusions.

Finish

Both anodized and painted finishes are available.

All integral colour anodizing is Architectural Class

II., 0.4 to 0.7 mm coating. A fluropolymer paint

coating conforming to the requirements of AAMA

603 and AAMA 605 specifications, the toughest

coating in the industry standards.

Testing

All testing shall be on full size frame sections. Air

infiltration shall be tested in accordance with

ASTM-Designation E283-91 or ASHRAE

standards #90-80

Fabrication

Framing should be fabricated from extrusions of

size and shape in accordance with shop

drawings. The framing system shall provide for

flush glazing while maintaining the 2” nominal

face dimensions.

The 550 Series has a complete number of

sections including deflection header and

extruded sub sill runner that can satisfy any

design requirements.

Construction

Frames shall have mechanically joined corners

with no exposed screws. All joints shall be

accurately fitted free of burrs and rough edges.

Complete frame assemblies shall be free of

warp. Each type of entrance framing systems is

compatible with all Standard Aluminum swing

doors and sliding mall fronts.

Installation

Experienced technicians in accordance with

approved shop drawings shall install all frames.

The frames shall be set plumb, square, and level

and in correct alignment and adjacent

construction. All anchoring shall suit the type of

construction of the perimeter work.

Protection and Cleaning

After installation the general contractor should

adequately protect the exposed aluminum and

glass surfaces from damage by other trades.

i.e.(but not restricted to) cement splash and

leach, grinding, polishing compounds, plaster,

paint, lime, acids and other contaminants.

STANDARD ALUMINUM PRODUCTS INC.

Wind Loads550 Series Flushed Glazed

SCALE 1/2 FULL SIZE

Calculations are based on CAN3-S157-M83 "Strength Design In Aluminum" using

6063-T5 Alloy-Temper, and a Deflection Limit = Span/175

2

5

6

7

8

9

10

11

12

13

14

15

3 4 5 6 8

Height (Feet)

Module Width, (Feet)

25 PSF

15 PSF

30 PSF

35 PSF

20 PSF

550 Series Storefront

2

7

8

9

10

11

12

13

14

15

16

18

3 4 5 6 8

Height (Feet)

Module Width, (Feet)

25 PSF

15 PSF

30 PSF

35 PSF

20 PSF

550 Series Storefront - Reinforced

7

17

19

20

7

550 Series Flushed GlazedSTANDARD ALUMINUM PRODUCTS INC.

4 1

/2

"

51mm

SCALE 1/2 FULL SIZE

2"

Storefront System

11

4m

m

2"

51mm

550

55

1

55

0

STANDARD ALUMINUM PRODUCTS INC.

555

4 1/2"

2"

550 Series Flushed GlazedStorefront System

114mm

51

mm

SCALE 1/2 FULL SIZE

550

554

554

553

S553

458

550

4 1

/2

"

4 1/2"

4 1

/2

"

11

4m

m

11

4m

m

114mm

2

1

/

4

"

Storefront System550 Series Flushed Glazed

STANDARD ALUMINUM PRODUCTS INC.

SCALE 1/2 FULL SIZE

55

1

551

559

558

557

Steel Reinforcing550 Series

STANDARD ALUMINUM PRODUCTS INC.

2"

51mm

3/4"

10

1m

m

4"

19mm

SCALE 1/2 FULL SIZE

55

0

55

1

STANDARD ALUMINUM PRODUCTS INC.

4 1

/2

"

2"

550 Series Flushed GlazedStorefront System

51mm

11

4m

m

51mm

2"

SCALE 1/2 FULL SIZE

550

556 556

55

0

55

1

STANDARD ALUMINUM PRODUCTS INC.

550 Series Flushed GlazedStorefront System

114mm

51

mm

SCALE 1/2 FULL SIZE

550

556

556

555

554

4 1/2"

2"

550T Series Flushed GlazedSpecification

STANDARD ALUMINUM PRODUCTS INC.

SCALE 1/2 FULL SIZE

Design

The system shall be 4 ½” x 2 1/4” Thermally

Broken center line flush glazing and accommodate

glass from 22mm to 25mm thick. The system can

be glazed from interior or exterior and is dry glaze.

Performance

See Wind load Charts.

Structural performance shall conform to CSA

Standard CAN3-S157 “Strength design in

Aluminum” and a maximum deflection of 1/175 of

the span.

Material

Extrusions shall be 6063 alloy and T5 Temper.

Glazing gaskets shall be EPDM elastomeric

extrusions.

Finish

Both anodized and painted finishes are available.

All integral colour anodizing is Architectural Class

II., 0.4 to 0.7 mm coating. A fluropolymer paint

coating conforming to the requirements of AAMA

603 and AAMA 605 specifications, the toughest

coating in the industry standards.

Testing

All testing shall be on full size frame sections. Air

infiltration shall be tested in accordance with

ASTM-Designation E283-91 or ASHRAE

standards #90-80

Fabrication

Framing should be fabricated from extrusions of

size and shape in accordance with shop

drawings. The framing system shall provide for

flush glazing while maintaining the 2 1/4” nominal

face dimensions.

The 550 Series has a complete number of

sections including deflection header and

extruded sub sill runner that can satisfy any

design requirements.

Construction

Frames shall have mechanically joined corners

with no exposed screws. All joints shall be

accurately fitted free of burrs and rough edges.

Complete frame assemblies shall be free of

warp. Each type of entrance framing systems is

compatible with all Standard Aluminum swing

doors and sliding mall fronts.

Installation

Experienced technicians in accordance with

approved shop drawings shall install all frames.

The frames shall be set plumb, square, and level

and in correct alignment and adjacent

construction. All anchoring shall suit the type of

construction of the perimeter work.

Protection and Cleaning

After installation the general contractor should

adequately protect the exposed aluminum and

glass surfaces from damage by other trades.

i.e.(but not restricted to) cement splash and

leach, grinding, polishing compounds, plaster,

paint, lime, acids and other contaminants.

STANDARD ALUMINUM PRODUCTS INC.

Wind Loads550T Series Flushed Glazed

SCALE 1/2 FULL SIZE

Calculations are based on CAN3-S157-M83 "Strength Design In Aluminum" using

6063-T5 Alloy-Temper, and a Deflection Limit = Span/175

2

5

6

7

8

9

10

11

12

13

14

15

3 4 5 6 8

Height (Feet)

Module Width, (Feet)

25 PSF

15 PSF

30 PSF

35 PSF

20 PSF

550T Series Storefront

2

7

8

9

10

11

12

13

14

15

16

18

3 4 5 6 8

Height (Feet)

Module Width, (Feet)

25 PSF

15 PSF

30 PSF

35 PSF

20 PSF

550T Series Storefront - Reinforced

7

17

19

20

7

STANDARD ALUMINUM PRODUCTS INC.

2 1/4"

SCALE 1/2 FULL SIZE

550T

55

1T

Storefront System550T Series Flushed Glazed

57mm

2 1/4"

4 1

/2

"

11

4m

m

57mm

550T

STANDARD ALUMINUM PRODUCTS INC.

554

555T

553T

554

4 1/2"

550T Series Flushed GlazedStorefront System

114mm

2 1

/4

"

57

mm

SCALE 1/2 FULL SIZE

550T

S553T

458T

550T

STANDARD ALUMINUM PRODUCTS INC.

4 1

/2

"

4 1

/2

"

4 1/2"

Storefront System550T Series Flushed Glazed

11

4m

m

114mm

11

4m

m

2

1

/

4

"

SCALE 1/2 FULL SIZE

559T

55

1T

551T

557T

558T

4 1

/2

"

57mm

11

4m

m

2 1/4"

57mm

2 1/4"

550T Series Flushed GlazedStorefront System

STANDARD ALUMINUM PRODUCTS INC.

SCALE 1/2 FULL SIZE

556

550T

550T

55

1T

556

STANDARD ALUMINUM PRODUCTS INC.

55

6

550T Series Flushed GlazedStorefront System

4 1/2"

114mm

2 1

/4

"

57

mm

SCALE 1/2 FULL SIZE

55

6

55

0T

555T

556

554

STANDARD ALUMINUM PRODUCTS INC.

Adjustable BaseSash & Stop

3 1

/2

"

5/8

"

Double Glazed

100-02 Double GlazedSection

100-01 Single GlazedSection

Adjustable BaseAdjustable BaseSingle Glazed

SCALE 1/2 FULL SIZE

3 1

/2

"

2 3

/8

"3

/4

"

#835

#855

#855

#835

2 3

/8

"

1 3/4"

1"

1 3/4"

1"

2mm

1/16"

2mm

1/16"

2mm

1/16"

2mm

1/16"

U-ChannelsSTANDARD ALUMINUM PRODUCTS INC.

1100 7575

1225

5750

1"

25mm

2 1

/4

"

57

mm

1/8"

3mm

1/8"

3mm

25mm

1"

1"

25

mm

3/4

"

19

mm

3/4"

19mm

3/4

"

19

mm

1/2"

13mm

5/8"

3/8"

5/8"

5/8"

5050

1/2

"

13

mm

1/2"

13mm

3/8"

7575A

3/4

"

19

mm

3/4"

19mm

SCALE - FULL SIZE

Miscellaneous TubingSTANDARD ALUMINUM PRODUCTS INC.

175450

1 3

/4

"

44

mm

44mm

1 3/4"

175175

1 3/4"

44mm

4 1

/2

"

11

4m

m

2.5mm

.100"

4"

.100"

175400

2.5mm

10

2m

m

1 3/4"

44mm

SCALE - FULL SIZE

.100"

2.5mm