2
CAMERA PARTS AND DEFINITIONS, DISASSEMBLING THE CAMERA Quick Start Guide 6/12MP Infrared Outdoor IP 360-degree Fisheye Camera Ax78R/98 i3-TRNG-CAMS-Ax78R/98-QSG.indd FW v.5.4.5; Rev. 190305 52 mm 168 mm iii iv v Ax78R/98 Camera Side view, with camera cover attached Use a Phillips screwdriver to remove the SD card panel cover (ii). to expose microSD card slot (iii) and the RESET pin hole (iv). Rubber gasket is provided for an airtight seal and moisture protection (v). CAMERA RESET To reset camera to factory defaults (incl. IP address and user management), unplug the network cable. Then use a sharp object to press the RESET button, re-connect the network cable and continue pressing the RESET button for 10 seconds. The camera will be rebooted and reset to factory defaults. Camera module with camera cover removed. 1. Built-in speaker 2. MicroSD card slot and RESET pin hole. Insert a micro SDHC card for backup/emergency recording and/or storage. 3. Light sensor for day/night switching 4. IR LEDs x3 5. Camera cover lock screw hole 6. Mounting screw hole/ slot x3 7. Camera cover clips x3 8. Built-in microphone 9. DC12V Power connector 10. RJ45 Network connector (PoE supported) Ax78R/98 Camera, Top view, with camera cover attached. Lift the safety lock screw cover to reveal the safety lock screw (i). Use a Phillips screwdriver to loosen the lock screw, then grip the camera cover and flex on one side, towards the center. Lift UP to remove. Scan this QR code or visit ftp.i3international.com to view and download AnnexxusConfigurationTool v1.5 (ACT) and the full User Manual. Use the ACT v1.5 or higher to set Ax78R/98 administrative password and IP address. Contact our Technical Support team at: 1.877.877.7241 or [email protected] if you have any questions or concerns regarding camera installation or if you require software services or support. QR Code to Full User Manual / ACT i ii 1 2 3 4 5 6 7 8 9 10 SAFETY When installing your Ax78R/98 camera be sure to avoid: excessive heat, such as direct sunlight or heating appliances contaminants such as dust and smoke strong magnetic fields sources of powerful electromagnetic radiation such as radios or TV transmitters moisture and humidity areas with mechanical vibrations fluorescent lamps or objects that reflect light unstable light sources as this may cause flickering temperatures below -30° Celsius or -22° Fahrenheit and above 60° Celsius or 140° Fahrenheit. POWER SUPPLY Ax78R/98 Power consumption requirement: DC 12V / PoE (IEEE 802.3af). Ensure the supplied voltage meets the power consumption requirements of this camera before powering the camera on. Incorrect voltage may cause irreparable damage to the video camera and will effectively void the camera warranty. PoE power is supported. CLEANING For maximum optical clarity, the camera dome or lens must remain clean. Use a soft, dry cloth to remove finger prints or dust from the dome cover. Use a blower to remove dust from the lens. Clean the body with a soft, dry cloth. If it is very dirty, use a cloth dampened with a small quantity of neutral detergent, then wipe dry. Do not use volatile solvents such as alcohol, benzene, or thinners, as they may damage the surface finishes. SERVICING To avoid electrical shock and to preserve the product warranty, DO NOT disassemble the camera. Refer servicing to qualified personnel only. PACKAGE CONTENTS Ensure that the items received match those listed on the order form and the packing slip. In addition to this manual and a fully assembled camera, the dome camera packing box includes: A. Waterproof RJ45 connector (pre-assembled) x1. Use to protect RJ45 connector from the moisture. B. Waterproof tape x1. Use to protect DC12V power connector from moisture. C. Plastic Anchor x4 D. Round Head Screw (Tapping Type) x4 E. RJ45 standar connector x2 F. Surface Mount template x1 1 1 1 TOP Drill Template Hole A : for cables routed through the ceiling Screw hole 1 : for Mounting Base A C D F Waterproof tape e Waterproof tape pe Waterproof ta f tape Waterproo oof tape Waterpr proof tape Water B E Camera module with camera cover removed.

Quick Start Guide - i3 International · 2019. 3. 14. · v Ax78R/98 Camera Side view, with camera cover attached Use a Phillips screwdriver to remove the SD card panel cover (ii)

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Quick Start Guide - i3 International · 2019. 3. 14. · v Ax78R/98 Camera Side view, with camera cover attached Use a Phillips screwdriver to remove the SD card panel cover (ii)

CAMERA PARTS AND DEFINITIONS, DISASSEMBLING THE CAMERA

Quick Start Guide6/12MP Infrared Outdoor IP 360-degree Fisheye Camera Ax78R/98

i3-TRNG-CAMS-Ax78R/98-QSG.indd FW v.5.4.5; Rev. 190305

52 m

m

168 mm

52 mm

168 mm

iii

iv

v

Ax78R/98 Camera Side view, with camera cover attached

Use a Phillips screwdriver to remove the SD card panel cover (ii). to expose microSD card slot (iii) and the RESET pin hole (iv). Rubber gasket is provided for an airtight seal and moisture protection (v).

CAMERA RESETTo reset camera to factory defaults (incl. IP address and user management), unplug the network cable. Then use a sharp object to press the RESET button, re-connect the network cable and continue pressing the RESET button for 10 seconds. The camera will be rebooted and reset to factory defaults.

Camera module with camera cover removed.

1. Built-in speaker2. MicroSD card slot and

RESET pin hole. Insert a micro SDHC card for backup/emergency recording and/or storage.

3. Light sensor for day/night switching

4. IR LEDs x35. Camera cover lock screw

hole6. Mounting screw hole/

slot x37. Camera cover clips x38. Built-in microphone9. DC12V Power connector10. RJ45 Network connector

(PoE supported)

Ax78R/98 Camera, Top view, with camera cover attached. Lift the safety lock screw cover to reveal the safety lock screw (i). Use a Phillips screwdriver to loosen the lock screw, then grip the camera cover and flex on one side, towards the center. Lift UP to remove.

Scan this QR code or visit ftp.i3international.com to view and download AnnexxusConfigurationTool v1.5 (ACT) and the full User Manual. Use the ACT v1.5 or higher to set Ax78R/98 administrative password and IP address. Contact our Technical Support team at: 1.877.877.7241 or [email protected] if you have any questions or concerns regarding camera installation or if you require software services or support. QR Code to Full

User Manual / ACT

i

ii

1

2

3

4

5

6

7

8

9

10

SAFETY When installing your Ax78R/98 camera be sure to avoid:• excessive heat, such as direct sunlight or heating appliances• contaminants such as dust and smoke• strong magnetic fields• sources of powerful electromagnetic radiation such as radios or TV transmitters• moisture and humidity• areas with mechanical vibrations• fluorescent lamps or objects that reflect light• unstable light sources as this may cause flickering• temperatures below -30° Celsius or -22° Fahrenheit and above 60° Celsius or 140°

Fahrenheit.

POWER SUPPLYAx78R/98 Power consumption requirement: DC 12V / PoE (IEEE 802.3af). Ensure the supplied voltage meets the power consumption requirements of this camera before powering the camera on. Incorrect voltage may cause irreparable damage to the video camera and will effectively void the camera warranty. PoE power is supported.

CLEANING• For maximum optical clarity, the camera dome or lens must remain clean. Use a soft,

dry cloth to remove finger prints or dust from the dome cover.• Use a blower to remove dust from the lens.• Clean the body with a soft, dry cloth. If it is very dirty, use a cloth dampened with a

small quantity of neutral detergent, then wipe dry.• Do not use volatile solvents such as alcohol, benzene, or thinners, as they may

damage the surface finishes.

SERVICINGTo avoid electrical shock and to preserve the product warranty, DO NOT disassemble the camera. Refer servicing to qualified personnel only.

PACKAGE CONTENTSEnsure that the items received match those listed on the order form and the packing slip. In addition to this manual and a fully assembled camera, the dome camera packing box includes:A. Waterproof RJ45 connector (pre-assembled) x1. Use to protect RJ45 connector from

the moisture.B. Waterproof tape x1. Use to protect DC12V power connector from moisture.C. Plastic Anchor x4 D. Round Head Screw (Tapping Type) x4E. RJ45 standar connector x2F. Surface Mount template x1 1 1

1

TOP

Drill TemplateHole A : for cables routed through

the ceilingScrew hole 1 : for Mounting Base

A C D F

Waterproof tape

e Waterproof tape

pe Waterproof ta f tape Waterproo

oof tape Waterpr

proof tape Water

B E

Camera module with camera cover removed.

Page 2: Quick Start Guide - i3 International · 2019. 3. 14. · v Ax78R/98 Camera Side view, with camera cover attached Use a Phillips screwdriver to remove the SD card panel cover (ii)

To activate and secure access to your camera, you must first set the password for the administrative user account (i3admin).IMPORTANT: Your camera will remain inactive and inaccessible until administrative password is set.

Activate your Annexxus 78R/98 camera by setting administrative password:1. Connect your Annexxus 78R/98 camera to the Gigabit switch. 2. On your i3 NVR, launch i3 Annexxus Configuration Tool (ACT) v.1.5 or higher.

You can download and install the latest ACT installation package from i3 website: https://i3international.com/download

3. In the top right-hand corner, click the gear icon and select Advanced Mode.

4. In the model drop-down list, select ANNEXXUS 78 or 98. Security status will say “inactive”.

5. In the Global Camera Settings, click Set Password

6. In the Set password window, enter the new password in the Password and Confirm fields. Follow secure password guidelines. Click OK. The new administrative password will be assigned to the camera and the Security status will change to “active”.

Change your Annexxus 78R/98 camera’s default IP Address:Note: Your i3 NVR must have a valid IP address (not APIPA)

7. In Annexxus Configuration Tool, select your Annexxus 78R/98 camera in the list.8. Uncheck “Default Account” and enter “i3admin” into Username field and the new

administrative password (set in Step 6) into Password field.

9. Enter the new IP address and Subnet Mask under Device(s) Communication Update and click Update.

10. Wait a few moments for a “Success” message in the Result field.11. Repeat Steps 7-10 for all detected Annexxus 78R/98 cameras in the ACT until

each camera has a unique IP address.12. To confirm your camera’s new IP address,

click the IE icon next to each camera. In the IE browser, enter administrative Username (i3admin) and (new) Password and click LOGIN. Annexxus camera interface will be displayed in the Internet Explorer window. You should be able to see the camera image on the screen. If you do not see the camera image on the screen, call i3 International technical support team for troubleshooting tips: 1.877.877.7241

ADDING CAMERA TO i3 SRX-PRO SERVER/SERVICE13. Ensure that the latest version of GiPi updater is installed on your SRX-Pro Server.

Latest GiPi available from https://i3international.com/download Note: SRX-Pro Server must be closed while GiPi updater is installed. Latest GiPi installer will automatically stop and re-start SRX-Pro Service during GiPi installation. After GiPi updater installation, re-start i3 SRX-Pro Server.

14. In SRX-Pro Server software or in SRX-Pro Console, go to Setup > IP Camera 15. Click the Search & Add button to display connected Annexxus cameras.16. Select the detected camera in the list and click Select.17. In the Select IP Camera window, enter the camera’s administrative User Name

(i3admin) and the (new) Password set in Step 6. Click Add. Selected camera will be added to the IP Camera list.

18. Assign the IP camera to the SRX-Pro video channel in the Ch In. column.19. To control ePTZ channels, go to Hardware tab and select i3 GiPi from the PTZ

Camera Type drop-down menu for the corresponding ePTZ channel.Your Annexxus 78R/98 camera is now connected to SRX-Pro Server / Service and is ready to record. Change resolution and frame rate for each video channel in the IP Camera tab menu or via Web Setup.

Ax78R/98 6/12MP IP Fisheye CameraQUICK START GUIDE

1.866.840.0004www.i3international.com

U.S.A 4450 Witmer Industrial Estates, Unit 4 Niagara Falls, NY 14305

Canada 780 Birchmount Road, Unit 16 Scarborough, ON, M1K 5H4

SURFACE MOUNTING

1. Use the Surface Mount Template to drill three (3) 6 mm (0.2”) screw holes at the marked template positions on the mounting surface.

2. Drill the cable opening at the marked template position.3. Insert three (3) supplied screw anchors into the drilled

holes in the mounting surface.129.5

112.

1

ø30

129.5

112.

1

ø30

129.5

112.

1

ø30

129.5

112.

1

ø30

• Use sealant at the locations shown on the mounting diagrams to maintain IP66 rating when installing outside.

• It is the installer’s responsibility to ensure that the mounting surface is suitable for the chosen installation method.

• Based on installation location and surface type, supplied screws and anchors may not be adequate; Mounting hardware is site-specific and may need to be supplied by the installer.

1 1

1

TOP

Drill TemplateHole A : for cables routed through the ceiling

Screw hole 1 : for Mounting Base

4. Use a Phillips screwdriver to insert supplied screws into the screw anchors. Leave enough screw length protruding from the each anchor to allow for the camera body to be rotated onto the screws.

5. Remove the camera cover. Use a Phillips screwdriver to loosen the safety lock screw, then grip the camera cover and flex on one side, towards the center. Lift UP to remove.

6. Feed the camera cabling through the cable opening drilled in the mounting surface.

7. Slide the protruding mounting screws through three matching mounting screw holes on the camera body and rotate the camera clockwise to secure the camera body on the mounting surface. Use a Phillips screwdriver to tighten three mounting screws in place.

8. Replace the camera cover. Match up the safety lock screw with the screw hole on the camera body, then push straight down onto the camera cover to engage the clips. The camera cover will re-attach.

9. Use a Phillips screwdriver to re-tighten the safety lock screw.

CONNECT CAMERA TO i3 SRX-PRO SERVER

i3 SRX-Pro Server

Crossover direct connection

LAN

i3 SRX-Pro Server

Via Gigabit Switch

Connection Type 1: Must use DC 12V Power for this connection type.

Connection Type 2:

Annexxus 78R/98 ChannelsDepending on Ax78R/98 configuration, multiple separate video channels/inputs are added to IP Camera setup tab of the SRX-Pro Server. Only one (1) IP license is required for all channels.To switch between modes, use the web browser. Camera must be removed and re-added to the SRX-Pro Server’s IP Camera tab after a Mode change.

Camera’s default IP address: 192.0.0.16.Camera’s default Subnet mask address: 255.255.255.0.Default User name: i3admin

ACTIVATING CAMERA, CHANGING IP ADDRESS in ACT