Upload
patrick-wells
View
359
Download
6
Embed Size (px)
Citation preview
8/9/2019 Raisecom Datasheet_iTN167_USA 2.0 Certified
1/6
Raisecom Technology Co., Ltd
Datasheet
Technology Co., Ltd. www.raisecom.com
America Headquarters3031 N. Rocky Point Dr. W. Suite 100
Tampa, Florida. 33602. USA.
Tel: +1 888 816 4808
Fax: +1 727 547 9124
Email: [email protected]
Copyright@1999-2014
All rights reserved
Technical information is subjected
to change without notice
iTN167-4GC
Intelligent Service Transmission Series
The iTN167-4GCdevice provides 2xGE SFP NNI and 4x1GE UNI interfaces.
It can work as the remote device on the PTN to transmit Ethernet leased
line services through flexible software configurations; also can works as
EDD of Ethernet CEN. iTN167-4GCcan act as an independent SNMP node
when connected to any PTN standard equipment. When connected to
iTN8800 service aggregation platform, iTN167-4GC can act as a spoke
device providing iTN8800 the ability to fully manage the remote CPE
units. With powerful OAM capabilities, RFC2544 and a unified control
plane with iTN8800; iTN167-4GC is the ideal solution for zero touch
provisioning deployments.
iTN167
Highlights
Network Security Upgraded security with port-isolation, broadcast/multicast/DLF storm control, unique port
loopback detection, and DHCP Client functionality
Resiliency &Protection Supports ITU-T G.8031 linear and ITU-T G.8032 ring protection with switching time less than
50ms;
Supports IEEE 802.1ax Link Aggregation
OAM Supports IEEE 802.3ah Link OAM, IEEE 802.1ag end-to-end connectivity OAM and ITU-T Y.1731
end-to-end service and performance, SLA reporting
Management Support Auto-Provisioning, plug&play, single IP for all the connected remote devices
End to end configuration
SAT Service activation test using Y.1564 up to 8 stream, act as a generator or a reflector
QoS Advanced QoS technology allows stream-marking based on CoS, DSCP, IP precedence and
priority;
Scheduling modes including SP, WRR, SP+WRR; WRED
Supports flow-based mirroring/rate-limit/redirection/VLAN swapping and rewriting
Power Reliability Dual hot-swappable power supply, with voltage/temperature alarms
8/9/2019 Raisecom Datasheet_iTN167_USA 2.0 Certified
2/6
Raisecom Technology Co., Ltd
Datasheet
Technology Co., Ltd. www.raisecom.com
America Headquarters3031 N. Rocky Point Dr. W. Suite 100
Tampa, Florida. 33602. USA.
Tel: +1 888 816 4808
Fax: +1 727 547 9124
Email: [email protected]
Copyright@1999-2014
All rights reserved
Technical information is subjected
to change without notice
Backhaul
Products involved
iTN167
Products involved
Remote Unit:
iTN100 series
Aggregation Unit:
iTN201
8/9/2019 Raisecom Datasheet_iTN167_USA 2.0 Certified
3/6
Raisecom Technology Co., Ltd
Datasheet
Technology Co., Ltd. www.raisecom.com
America Headquarters3031 N. Rocky Point Dr. W. Suite 100
Tampa, Florida. 33602. USA.
Tel: +1 888 816 4808
Fax: +1 727 547 9124
Email: [email protected]
Copyright@1999-2014
All rights reserved
Technical information is subjected
to change without notice
Features
Switching Mode Store and forward mode; Non-blocking switching
Packet Forwarding MTU: up to 13000 byte
Bandwidth Profile Rate limit:1,00,000Kbps
Burst configuration (Max 16000B)
Ingress rate limit per port
Egress flow shaping per port
Rate limit per VLAN
Increments:64Kbps
VLAN IEEE 802.1Q VLAN: 4K active VLANs;
Port-based VLAN
Storm Control Broadcast/multicast/unicast/DLF storm control per port
Mirror Mirroring per port
Separate mirroring configurations foringress & egress ports
Power loss alarm Alarm reporting in case of power loss
Detect remote site power loss
Loopback Detection Auto shutdown individual ports uponfault signals
MAC Address Table 8K MAC address
Add/remove MAC address
View MAC address statistic
Search MAC address
Aging time:10-1,000,000s
MAC table threshold per port
MAC table limit:1-8k
MAC address black list or white list
Q-in-Q Port/flexible Q-in-Q
Link Aggregation
Up to 3 groups and 4 ports per group
Load balancing based on MAC/ IP
Standard LACP (static only)
Support 1:1 redundancy mode
Flow Control IEEE 802.3x in full duplex mode
Back pressure in half duplex mode
8/9/2019 Raisecom Datasheet_iTN167_USA 2.0 Certified
4/6
Raisecom Technology Co. Ltd
Datasheet
Technology Co. Ltd. www.raisecom.com
America Headquarters3031 N. Rocky Point Dr. W. Suite 100
Tampa, Florida. 33602. USA.
Tel: +1 888 816 4808
Fax: +1 727 547 9124
Email: [email protected]
Copyright@1999-2014
All rights reserved
Technical information is subjected
to change without notice
Digital Diagnostic
SFP digital diagnostic function
Port Backup Supported
L2CP transparency BPDU; DOT1X; LACP; CDP; VTP; PVST
Advanced
Auto-Provisioning As remote unit can be discovered by iTN200\iTN2100\iTN8800
Plug & Play with configuration automatically load from NView
SAT Service activation test using Y.1564 up to 8 stream
Act as a generator or a reflector
EFM IEEE802.3ah OAM including discovery, link performance, remote
loopback, fault detection & performance stats per OAM standards
OAM Active/Passive mode
OAM MIB Variable Get function
OAM Event function
Extended OAM (configure on remote switches)
CFM IEEE802.1ag/ITU-T Y.1731 protocol: up to 256 MEP, 256 MA
Connectivity check (CC); Loopback (LB);Linktrace (LT); Performance
Monitor(PM)
SLA Layer-2/Layer-3 SLA (frame delay, jitter & packet loss) based on Y.1731
SystemManagement CLI/ARP/Telnet/Console/SNMP /SSH
16 inband IP interfaces
RMON1,2,3 & 9
Bridge MIB (RFC1493)
Raisecom NMS
System log
Hierarchical alarms
Link alarm per port
Fault pass through
Module information management
Maintenance Debug information output
PING (packet internet groper)
Telnet client
Port statistic
Port dynamic statistic
QoS Global CoS/DSCP to queue mapping
Port TRUST mode: CoS/DSCP/port priority
8/9/2019 Raisecom Datasheet_iTN167_USA 2.0 Certified
5/6
Raisecom Technology Co., Ltd
Datasheet
Technology Co., Ltd. www.raisecom.com
America Headquarters3031 N. Rocky Point Dr. W. Suite 100
Tampa, Florida. 33602. USA.
Tel: +1 888 816 4808
Fax: +1 727 547 9124
Email: [email protected]
Copyright@1999-2014
All rights reserved
Technical information is subjected
to change without notice
Specifications
Performance
Switching fabric: 12Gbps;
Indicators Power Supply (flashing);
SFP port: LINK/ACT; Speed;
Compliances
Standards
protocols
IEEE 802.1Q VLAN
IEEE 802.1ax Link Aggregation
ITU G.8031 linear protection
Global queue scheduling with 8 queues per port
Scheduling mode: SP/WRR/SP+WRR
WRR weight range:1-127
Flow statistics
Flow-based mirror/rate-limit/ redirection/VLAN swapping/rewriting of
802.1p CoS, DSCP,IPpriority
HCAR Easy way to apply a HCAR to a service and a port
G.8031/8032 G.8031 linear protection
G.8032 ring protection
ACL MAC/IP-based ACL
ACL map (L2~L4 byte)
Safety Features Client classification and password protection
RADIUS
TACACS+
Binding of MAC address & port
Port protection
Password Recovery Supported
Filter ACL hardware filter
LLDP Discovery remote base on link layer
Get remote basic information
Error Tolerance
Redundancy
System error report
Fast recovery during serious error
Scheduling System task scheduling
MEF 9 14 Supported
Time Management Timezone; Time modification
Support SNTP & NTP
Software Upgrade Xmodem/FTP upgrade in BOOTROM
FTP/TFTP
2 system software image
DHCP
DHCP Client
Support option61
IPv6 IPv6 ACL
8/9/2019 Raisecom Datasheet_iTN167_USA 2.0 Certified
6/6
Raisecom Technology Co., Ltd
Datasheet
Technology Co., Ltd. www.raisecom.com
America Headquarters3031 N. Rocky Point Dr. W. Suite 100
Tampa, Florida. 33602. USA.
Tel: +1 888 816 4808
Fax: +1 727 547 9124
Email: [email protected]
Copyright@1999-2014
All rights reserved
Technical information is subjected
to change without notice
Physical Interface
Management port: 1 console (USB);
1 outband SNMP(RJ45)
Client interfaces:
4x 10/100/1000Mbps Base-TRJ45 port
or 4 RJ45+SFP COMBO port;
Network interfaces:
2 x1Gbps SFP port
Power Specs
User Conditions
Dimensions
Weight
AC: 100~240V, 47~63Hz;
DC: -48V
Full load: 25W
Operating temp: -40~55C (-40~131F);
Storage temp: -25~60C (-13~140F);
Humidity: 10~90% non-condensing
220(W) x 180(W) x 44(H) mm3
2.5Kg
ITU G.8032 ring protection
IEEE 802.1ad QinQ
IEEE 802.1p CoS Prioritization
IEEE 802.3x Flow Control
IEEE 802.3ah OAM
IEEE 802.1ag Connectivity Fault
Management
ITU Y.1731 Services OAM
RMON I and II standards
SNMPv1/v2c/v3
MEF9 MEF14
CE2.0 certificed
Ordering Information
iTN167 GC AC
PTN Device, 2 x GE SFP NNI + 4 x combo GE UNI ports, dual AC power supplies, includes RM kit
iTN167 GC C PTN Device, 2 x GE SFP NNI + 4 x combo GE UNI ports, dual 48vDC power supplies, includes RM kit
iTN167-4GC-DC/D +24vDC)
PTN Device, 2 x GE SFP NNI + 4 x combo GE UNI ports, dual +24vDC power supplies, includes RM kit