8
RATIONAL Revit Families Readme – Version 051818 Page 1 of 8 1. Overview projects The Rational Revit families are based on Revit version 2016. There are 3 overview projects available for download. They contain all families, types and options at a glance. You can open the families from here and copy them into your project. Note also the schedule in these projects. They contain all appropriate Rational schedule properties. RATIONAL_Revit_Families_Overview_CombiSteamer_Electric.rvt RATIONAL_Revit_Families_Overview_CombiSteamer_Gas.rvt RATIONAL_Revit_Families_Overview_Accessories.rvt

RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

Embed Size (px)

Citation preview

Page 1: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 1 of 8

1. Overview projects

The Rational Revit families are based on Revit version 2016. There are 3 overview projects available for download. They contain all families, types and options at a glance. You can open the families from here and copy them into your project. Note also the schedule in these projects. They contain all appropriate Rational schedule properties.

RATIONAL_Revit_Families_Overview_CombiSteamer_Electric.rvt

RATIONAL_Revit_Families_Overview_CombiSteamer_Gas.rvt

RATIONAL_Revit_Families_Overview_Accessories.rvt

Page 2: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 2 of 8

2. Instance Properties for 61, 62,101, 102 units

Note the specific properties in the Properties dialog for the single units.

Construction options

These checkboxes allow you to enable the features - Mobile or Standard Feet - Marine Version (Electric units only) - Integrated Fat Drain - Stand options - Ultravent / UltraVent Plus/UltraVent Baking - Ultravent Plus is available for the following electric units: 61, 62, 101, 102 and 201 Combi-Duo 61/61 and 61/101 - UltraVent Baking for for the electric units: 61, 101, 61/61, 61/101

Panel options

SCC

CMP

With these options you can switch between - SCC panel - CMP panel The option “Model SCC” shows the new front design. If you enable the checkbox “OEM version”, a white area is used instead of the Rational logo.

Swing options

These options define the swing direction of the door. The swing direction is displayed in 2D, if the option “Door Swing in Plan View” is activated.

Wall Clearance

The wall clearance options shows the required installation space in 2D and 3D.

Page 3: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 3 of 8

3. Instance Properties for 201, 202 units

Note the specific properties in the Properties dialog for the 201 and 202 units.

Construction options

These checkboxes allow you to enable the features - Mobile or Standard Feet - Marine Version (electric units only) - Fat Drain Left / Right - Exhaust Hood Ultravent/UltraVent Plus

Panel options

SCC

CMP

With these options you can switch between - SCC panel - CMP panel The option “Model SCC” shows the new front design. If you enable the checkbox “OEM version”, a white area is used instead of the Rational logo.

Swing option

The swing direction is displayed in 2D, if the option “Door Swing in Plan View” is activated. 201 and 202 units support only right door swing.

Wall Clearance

The wall clearance option shows the required installation space in 2D and 3D. With exhaust hoods, the clearance is 450mm above the hood.

Page 4: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 4 of 8

4. Instance Properties for 61/61, 62/62, 61/101, 62/102 units

Note the specific properties in the Properties dialog for the Combi-Duo units.

Construction options

These checkboxes allow you to enable the features - Mobile or Standard Feet - Standard or Small Rollers - Marine version (electric units only - UG I Stand (selected electric units only) - Fat drain Left / Right - UltraVent / UltraVent Plus / UltraVent Baking

Panel options

SCC

CMP

With these options you can switch between - SCC panel - CMP panel The option “Model SCC” shows the new front design. If you enable the checkbox “OEM version”, a white area is used instead of the Rational logo.

Swing options

These options define the swing direction of the door. The swing direction is displayed in 2D, if the option “Door Swing in Plan View” is activated.

Wall Clearance

The wall clearance option shows the required installation space in 2D and 3D and reacts on the Fat Drain options

Page 5: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 5 of 8

5. Detail Levels

All Rational families support the Revit detail levels Coarse, Medium, Fine in 2D and 3D views.

6. MEP Connectors

All Rational families contain MEP connectors to create Revit MEP systems. The connectors are set for electric, waste water, cold water in and gas.

7. Visualization

All Rational families contain material parameters with default Rational materials. Use the instance parameter "Rack material" to visualize different contents for the racks. To see the materials in realistic views and renderings, download and extract the Textures.zip from the Rational web site and set the "Additional Render Appearance Paths" in the Revit Options dialog to the folder where you have unzipped the jpg's.

8. Type Properties

Page 6: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 6 of 8

The Type Properties of the units contain parameters according the FCSI standards.

Page 7: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 7 of 8

9. Listing of families Combi-steamer Gas

Combi-steamer Electric

Accessories

Page 8: RATIONAL Revit Families Readme EN · RATIONAL Revit Families Readme – Version 051818 Page 2 of 8 2. Instance Properties for 61, 62,101, 102 units Note the specific properties in

RATIONAL Revit Families Readme – Version 051818

Page 8 of 8

10. Version history The following features are added in version 092016:

- Integration of Exhaust Hood Ultravent Plus for selected electrical units - New front design for SCC units - Integration of XSE and XSE / XSE units including stands - New version parameter added

The following features are added in version 022017:

- Exhaust hood UltraVent Baking for 61E, 101E, 61E/61E, 61E/101E

- Exhaust hood UltraVent for 202E - Stand UG II und UG XS for XSE units - Integration kit for XSE units - Stand UG II for XSE / XSE units - Renaming of the families according FCSI standards - Integration of he latest FCSI / IFSE parameters

The following features are added in version 102017:

- Families are updated to Revit version 2016 - Marine version for XSE units - CMP panels for XSE and XSE/XSE units - Exhaust Hood UltraVent Plus for XSE and XSE/XSE units - New type 61E 3AC 240V for 61E units - New 208V types for XSE units - Marine version only types for XSE units - New type XSE 3AC 220V Korea added - UG I Stand Standard and Mobile for 61G/61G and 62G/62G units

The following features are added in version 051818:

- Mobile version for XSE XSE and XSE/XSE units with UG I stand

Marine version for XSE/XSE units with UG II stand - Revised Marine Feet geometry for all electrical units and stands - New UltraVent E US and UltraVent Plus E US exhaust hoods - Electrical connector for exhaust hoods - New parameters Exhaust Hood Volts and Exhaust Hood Watts for electrical units with

exhaust hoods. The values are calculated based on the selected exhaust hood - UG I stand for 61 and 62 combi-duos as standalone family