Upload
ytngllc197006458
View
215
Download
0
Embed Size (px)
Citation preview
7/27/2019 Real-Time Polymerase Chain Reaction for the Food Microbiologist
1/5
Vol. 70, Nr. 3, 2005JOURNAL OF FOOD SCIENCE R49Published on Web 3/17/2005
2005 Institute of Food TechnologistsFurther reproduction without permission is prohibited
R : C o n c i s e R e v i e w s i n F o o d S c i e n c e
JFS R: Concise Reviews/Hypotheses in Food Science
Real-time Polymerase Chain Reactionfor the Food Microbiologist:Technologies, Applications, and LimitationsSSSSSCCCCCOOOOOTTTTTTTTTT E. HE. HE. HE. HE. HANN AANNAANN AANNAANN A, C, C, C, C, CHRISTHRISTHRISTHRISTHRISTOPOPOPOPOPHERHERHERHERHER J. CJ. CJ. CJ. CJ. CONNORONNORONNORONNORONNOR,,,,, ANDANDANDANDAND HHHHHUUUUUAAAAA H.H.H.H.H.WWWWWANGANGANGANGANG
ABSTRAABSTRAABSTRAABSTRAABSTRACTCTCTCTCT: R: R: R: R: Rapid detection of pathogenic and spoilage micrapid detection of pathogenic and spoilage micrapid detection of pathogenic and spoilage micrapid detection of pathogenic and spoilage micrapid detection of pathogenic and spoilage microorooroorooroorganisms is essential for ensurganisms is essential for ensurganisms is essential for ensurganisms is essential for ensurganisms is essential for ensuring the safety anding the safety anding the safety anding the safety anding the safety andquality of food. Real-time polymerase chain reaction (PCR) technology has the potential to achieve rapid, sensitive,quality of food. Real-time polymerase chain reaction (PCR) technology has the potential to achieve rapid, sensitive,quality of food. Real-time polymerase chain reaction (PCR) technology has the potential to achieve rapid, sensitive,quality of food. Real-time polymerase chain reaction (PCR) technology has the potential to achieve rapid, sensitive,quality of food. Real-time polymerase chain reaction (PCR) technology has the potential to achieve rapid, sensitive,and specific detection of these micrand specific detection of these micrand specific detection of these micrand specific detection of these micrand specific detection of these microorooroorooroorganisms in food. Iganisms in food. Iganisms in food. Iganisms in food. Iganisms in food. In this rn this rn this rn this rn this reviewevieweviewevieweview, w, w, w, w, we discuss re discuss re discuss re discuss re discuss real-time PCR technologies ineal-time PCR technologies ineal-time PCR technologies ineal-time PCR technologies ineal-time PCR technologies inuse todayuse todayuse todayuse todayuse today, applications of r, applications of r, applications of r, applications of r, applications of real-time PCR in food systemseal-time PCR in food systemseal-time PCR in food systemseal-time PCR in food systemseal-time PCR in food systems, and some of the associated challenges and limitations, and some of the associated challenges and limitations, and some of the associated challenges and limitations, and some of the associated challenges and limitations, and some of the associated challenges and limitations.....
Keywords: real-time PCR, rapid methods, food microbiologyKeywords: real-time PCR, rapid methods, food microbiologyKeywords: real-time PCR, rapid methods, food microbiologyKeywords: real-time PCR, rapid methods, food microbiologyKeywords: real-time PCR, rapid methods, food microbiology
Introduction
Contamination by foodborne pathogens is a great threat to hu-man health; the estimated cost of foodborne illness in the Unit-ed States is between $10 billion and $83 billion annually (USFDA
2001). In addition, food spoilage due to outgrowth of spoilage or-
ganisms costs the food industry significant amounts of money
through the loss of raw material and finished product, product re-
calls, loss of sales due to reduced consumer confidence, and poten-
tial litigation. While sterilization could eliminate the presence of mi-
croorganisms in the final products, extreme processing conditions
often cause undesirable physiochemical changes and loss of nutri-
tional values of the food products that lead to consumer unaccept-
ability. Therefore, achieving final product quality assurance
through controlling the quality of raw materials and verification ofthe lack of target pathogenic and spoilage organisms in the final
products are still the main choices for the food industry.
When compared with clinical diagnostics, there are several chal-
lenges associated with microbial detection in foods. The initial con-
tamination level in foods is normally low, and sampling with repre-
sentation could be difficult (Jaykus 2003). Foods not only provide
nutrients supporting the growth of microorganisms, but various
ingredients can interfere with the activities of enzymes involved in
detection. In products such as fermented foods, the background
microbial count could be fairly high. Finally, many foods have lim-
ited shelf-life. Therefore, timely detection of these organisms with
high degrees of specificity and sensitivity to maintain a safe, whole-
some food supply is a major task for food microbiologists.
Although methods such as microbial culturing and biochemical
assays have proven to be useful in quality control, they still cannot
meet all the demands of the food industry because of their intrinsic
limitations. For instance, because normal bacteria generation time is
approximately 20 to 40 min, it can take anywhere from 18 h to several
days for enough microbial multiplication to occur to allow for bacterial
culturing or metabolism-based detection. More sensitive and rapid
detection is desired, and one of the recent attempts to fill this need
has been with polymerase chain reaction (PCR) technology.
Conventional PCR
PCR technology has been used to rapidly detect, characterize,and identify a variety of organisms (Campbell and Reece1996). In a conventional PCR setting, a pair of oligonucleotide prim-
ers complementing to sequences at both ends of the target gene,
DNA from the target organism to act as a template, free nucleotides,
salts, and DNA polymerase are combined in a reaction mixture,
resulting in the replication of the target DNA fragment. This repli-
cation of an individual DNA fragment, known as amplification, can
be achieved within a minute or two. Because the amplification is an
exponential process, after repeated rounds of this amplification
using a thermal cycler, enough copies of the fragment will have
accumulated to be detectable. Therefore, the presence of even 1
copy of the template within the reaction mixture can be detectedwithin a couple of hours.
Some DNA sequences are similar across class or genus lines, and
others are unique to a particular species or strain. Because primers
can be designed to target specific DNA sequences conserved at
these various levels, detection of the presence of a microbial genus,
species, or strain can be achieved by observation of the targeted
PCR products. Since its invention, many studies have shown the
effectiveness of PCR for rapid detection of numerous species of
bacteria (Allmann and others 1995; Kaiser and others 2001; Maki-
no and others 2001; Jensen and Whitfield 2003; Malinen and others
2003).
PCR can be a powerful tool for analysis, but it has some short-
comings that limit its effectiveness in many cases. Nonspecific
amplification is a major problem associated with PCR. Particularly
under low-stringency conditions, such as low reaction tempera-
tures, primers might anneal to regions with minor mismatches and
amplify unrelated PCR products. This can lead to false-positive
results. In addition, hairpin loop formation, in which 2 segments of
a single primer hybridize with each other, can not only prevent the
primers from binding to the desired template but also result in the
formation of an undesired fragment. Also, 2 primers with comple-
menting sequences can bind to each other and form primer
dimers, which can be detected as a nonspecific amplification prod-
uct (Miller and others 1996).
Other PCR limitations have also been documented. For instance,
detection of the target DNA fragment using gel electrophoresis
must be carried out after PCR amplification has taken place, creat-
MS 20040446 Submitted 7/2/04, Revised 9/27/04, Accepted 12/12/04. Theauthors are with Dept. of Food Science and Technology, The Ohio State Univ.,Columbus, Ohio 43210. Direct inquiries to author Wang (E-mail:[email protected]).
mailto:[email protected]:[email protected]7/27/2019 Real-Time Polymerase Chain Reaction for the Food Microbiologist
2/5
R50 JOURNAL OF FOOD SCIENCEVol. 70, Nr. 3, 2005 URLs and E-mail addresses are active links at www.ift.org
R
C
i
R
i
iF
d S
i
Real-time PCR for the food microbiologist . . .
ing a need for additional labor as well as allowing opportunities for
carry-over contamination of PCR products (Fratamico 2001). And in
rare cases, reagents might cause a contamination problem due to
improper purification during the manufacturing process (Corless
and others 2000).
Real-time PCR
OverviewOverviewOverviewOverviewOverview
Recent advancements in PCR technology include the develop-
ment of real-time PCR devices and the application of new amplifi-
cation product-detection chemistries. Real-time PCR adds an op-
tical module to a standard PCR assay, allowing the capture of
fluorescent signals from labeled PCR products. This method of
detecting the amplicon, the fragment of DNA replicated during the
PCR reaction, is the main difference between conventional and
real-time PCR technologies, as the instrument detects the intensity
of the fluorescent signal during each replication cycle of the PCR
(Mackay 2004). Computer software records and displays the
amount of fluorescence in relative fluorescence units (RFU). The
amplification cycle at which the fluorescence exceeds a defined
threshold level is known as the threshold cycle (Ct) (Corless and
others 2000). Data analysis software enables real-time calculationand plotting, eliminating the need for the post-amplification anal-
ysis of conventional PCR.
This ability to detect the presence of DNA throughout the entire
replication process, rather than just the end result, is one of the
main advantages of real-time over conventional PCR. Deviations in
amplification efficiency can be easily seen, and quantification is
much more precise (Schmittgen and others 2000). Furthermore,
real-time PCR offers a better platform for multiplexing, the detec-
tion of more than 1 target DNA fragment in a single reaction tube.
Simultaneous monitoring of multiple fluorophores and melting
curve analysisdetermining the temperature at which the indi-
vidual double-stranded DNA amplicons separate, or meltmake
this detection of multiple genes or multiple organisms possible.Finally, because many real-time PCR approaches involve the use of
a 3rd oligonucleotide that must also anneal to the target DNA se-
quence, they can offer improved detection specificity.
Because the amplification is monitored during the reaction, real-
time PCR can be used for quantification of the target as well as
basic detection. The higher the number of copies of the target DNA
that exist in the original sample, the earlier in the reaction that sam-
ples fluorescence will cross the threshold. The Ct produced from a
given sample can then be compared with a standard curve, gener-
ated from serial dilutions of a known amount of the target DNA, to
obtain the initial starting copy number (Ibekwe and others 2002).
Detection chemistriesDetection chemistriesDetection chemistriesDetection chemistriesDetection chemistries
Nucleic acid dyes.Nucleic acid dyes.Nucleic acid dyes.Nucleic acid dyes.Nucle ic acid dyes. Several types of real-time PCR assays have
been used in research and clinical settings. One type of assay uses
a fluorescent dye that binds to nucleic acids and returns a signal to
the optical module on the thermal cycler. One commonly-used flu-
orescent dye is SYBR Green I, which can be used in assays designed
to detect many different targets (Ramos-Payan and others2003).
SYBR Green I assays do not require a specific probe to be devel-
oped, as in some other assays.
SYBR Green I assays can provide useful quantitative informa-
tion, but the dye binds to any double-stranded DNA molecules in
the reaction, including nonspecific PCR products or primer dimers
(Missel and others 2001; Ramos-Payan and others 2003). False pos-
itives can arise if the PCR primers amplify any nonspecific products
other than the targeted sequence, although melting curve analy-
sis can help differentiate various products. The melting point of
double-stranded DNA increases with longer length and higher G-
C content. By analyzing the temperatures at which the DNA strands
separate, releasing the dye and therefore reducing the fluores-
cence, a distinction can be made between the desired amplicon
and any nonspecific products, or between different amplicons in a
multiplexed reaction (Wang and others 2004). For instance, Escher-
ichia coliO157:H7, Listeria monocytogenes, and Salmonella strains
in fresh produce have been detected simultaneously using SYBR
Green I and melting curve analysis (Bagwhat 2003). SYBR Green I
assays ultimately provide a relatively inexpensive and fairly sensi-
tive method for detecting double-stranded DNA (Missel and others
2001; Malinen and others 2003) and can even incorporate existing
primers already in use for conventional PCR assays (Bagwhat 2003,
2004). Recently, SYBR Green I was added to the reaction mix of the
original commercially available BAX test for Salmonella, successfully
transforming this conventional PCR test into a more rapid real-
time method (Bagwhat 2004).
Molecular beacons.Molecular beacons.Molecular beacons.Molecular beacons.Molecular beacons. Another permutation of real-time PCR is the
implementation of molecular beacons, which are single-stranded
oligonucleotide molecules between 25 and 35 bases in length
(Pierce and others 2000). Five to eight bases on the 3 and 5 ends
must complement, forming an intentional hairpin loop secondarystructure. The theory of this chemistry is to incorporate a quencher
dye on the 3 end and a fluorescent dye on the 5 end; when the 2
dyes are near each other, the quencher absorbs or modifies the sig-
nal produced by the fluorophore. When the beacon binds to an
external complementary sequence, the internal hairpin structure
is flattened out and emission from the fluorescent dye is recorded
by the optical module (Pierce and others 2000).
The development of molecular beacons can be more difficult than
other types of probes because even a single base pair mismatch can
prevent detection by the system. If such a mismatch occurs, the
beacon will remain in the more thermodynamically stable hairpin
loop instead of binding to the template (Tyagi and Kramer 1996).
This property of molecular beacons can be used to create extremelyspecific assays that other types of probes may not achieve.
TTTTTaqMaqMaqMaqMaqMan pran pran pran pran probesobesobesobesobes..... The TaqMan real-time PCR assay can overcome
some of the pitfalls of SYBR Green I and the lack of flexibility of
molecular beacons. The TaqMan-based assay includes a fluorogen-
ic probe (a 3rd oligonucleotide) that binds specifically to the ampl-
icon. TaqMan probes are designed with the fluorescent reporter
dye on the 5 end and the quenching dye on the 3 end. When the
probe anneals to the amplicon, the 5 exonuclease activity of the
DNA polymerase cleaves the probe. This step frees the 5 reporter
dye, which prevents the quencher dye from masking the fluores-
cence and allows the optical module to record emission (Giuletti and
others 2001).
One advantage of the TaqMan assay is added specificity over
SYBR Green I assays because the probe will only bind to the de-
sired sequence within the amplicon. Unlike molecular beacons,
TaqMan probes can bind to template DNA containing minor base
pair mismatches, although with reduced efficiency. If the concen-
tration of mismatched products is high, signals generated from
them can be detected as well.
OOOOOther chemistrther chemistrther chemistrther chemistrther chemistriesiesiesiesies..... A fairly new type of chemistry, intended to
decrease the time needed to generate a fluorescent signal and to
improve reliability, is the scorpion probe. This technology incorpo-
rates the primer and probe as a single unit, with a quencher and a
fluorophore held in close proximity similar to the molecular beacon.
This also creates a more thermodynamically stable product during
the PCR reaction than with the separate primers and probe ap-
proach. During the PCR process, the primer end begins replication
http://www.ift.org/http://www.ift.org/http://www.ift.org/7/27/2019 Real-Time Polymerase Chain Reaction for the Food Microbiologist
3/5
Vol. 70, Nr. 3, 2005JOURNAL OF FOOD SCIENCE R51URLs and E-mail addresses are active links at www.ift.org
R : C o n c i s e R e v i e w s i n F o o d S c i e n c e
Real-time PCR for the food microbiologist . . .
of the amplicon; the probe end then attaches to this new amplicon
after separation from the template DNA during the following melt-
ing phase. When the probe hybridizes with the amplicon, the fluo-
rescent marker is separated from the quencher and a signal is gen-
erated (Whitcombe and others 1999).
Yet another type of chemistry, hybridization probes use 2 differ-
ent labeled probes, or a labeled probe and labeled primer, for each
amplicon, one with a donor fluorophore and one with a receptor
fluorophore. These oligonucleotides are designed to lie head-to-tail
when annealed; in this configuration the donor transmits energy to
the receptor and the signal is generated (Giuletti and others 2001).
At melting temperatures, the probes separate from the template,
and the signal is eliminated until the next annealing step (Bernard
and Wittwer 2000). This chemistry holds promise for increasing the
multiplexing capabilities of real-time PCR because in addition to
using differing fluorescent markers, melting point analysis can be
performed to distinguish slightly differing DNA sequences (Bellin
and others 2001).
ApplicationsApplicationsApplicationsApplicationsApplicationsDue to the complexity of ingredients involved in food samples,
the applicability of real-time PCR in microbial detection needs to
be verified, and sample preparation procedures need to be opti-mized for each food commodity. In the past few years, a number of
DNA primers and probes specific for detecting certain foodborne
microorganisms have been developed, and sample preparation
procedures involved in detecting these organisms in certain types
of food have been reported. These studies are essential in evaluat-
ing the feasibility of implementing real-time PCR detection sys-
tems for food industry applications.
Taqman chemistry has been a popular choice in real-time PCR
detection because of its improved specificity, while still maintaining
flexibility in primer and probe design. The prominent foodborne
pathogens belonging to the genus Salmonella have been targets of
real-time PCR studies. UsinginvA gene specific TaqMan primers-
and-probe, Rodriguez-Lazaro and others (2003) reported 100%accuracy in detection of Salmonellae. This method was also more
convenient than traditional culture methods. The foodborne
pathogen L. monocytogeneshas also been a target organism for
real-time PCR detection. Hein and others (2001) developed an as-
say for milk targeting the iap gene ofL. monocytogenesand Listeria
innocua, enabling the specific detection of as few as 6 copies of the
target gene from the 2 organisms.
TaqMan chemistry has also been used for the detection ofE. coli
O157:H7. A study targeting both the stx1 and stx2shigatoxin-pro-
ducing genes was able to detect 10 colony-forming units (CFU)/g in
soil following a 16-h enrichment (Ibekwe and others 2002). Another
assay multiplexed stx1 and stx2along with a uidA sequence unique
to the O157:H7 strain, and achieved 98.6% sensitivity and 100%
specificity for this pathogen (Jinneman and others 2003). Detection
levels in this study were as low as 6 CFU/g. Vibrio choleraehas been
detected in raw oysters, with the detection of 6 to 8 CFU/g (Lyon
2001). This probe was tested on 60 bacterial strains from 21 differ-
ent genera and achieved 100% specificity for V. cholerae. An assay
has also been developed to detect Yersinia enterocolitica in raw meats
and tofu (Vishnubhatla and others 2001). This assay was capable
of detecting 102 CFU/mL in pure culture and 103 CFU/g in ground
pork; conventional culture methods detected only 105 CFU/mL and
106 CFU/g, respectively. Because the target sequence was the en-
terotoxinystgene, the assay could quickly and accurately identify
virulent strains.
Two Taqman real-time PCR assays have also been developed in
our laboratory to detect the presence of spoilage microorganisms.
A primer-and-probe set was developed targeting the shcgene en-
coding squalene-hopene cyclase, a key enzyme in hopanoid bio-
synthesis. Hopanoids are involved in maintaining membrane flu-
idity and stability in extreme environmental conditions. Using this
primer-and-probe set, the presence of spoilageAlicyclobacillusspp.
can be detected without cross-reactivity with other common food-
borne bacteria (Luo and others 2004). Using a primer-and-probe
set developed targeting the 16S rRNA-encoding gene, the presence
of all 7 species ofAlicyclobacillusand a few closely related thermore-
sistant bacteria can be detected by real-time PCR (Connor and oth-
ers 2005). In both cases, the presence of less than 100 cells/mL in
juice products can be directly detected without enrichment proce-
dures. The whole detection process can be completed within 5 h.
The OSU CleanPlant rapid detection system containing multiple
components for spoilage and pathogenic bacteria as well as molds
and yeasts is currently patent pending.
SYBR Green I assays have also been used for foodborne patho-
gen detection. As previously noted, the dye can be used in conjunc-
tion with primers designed for conventional PCR to create efficient
real-time assays (Bagwhat 2003, 2004). Listeria and Salmonella have
also been detected using multiplex real-time PCR at levels of 1 cell
per PCR reaction using an overnight (16 h) enrichment process
(Jothikumar and others 2003). This group also detected Listeria andSalmonella in sausage using multiplex real-time PCR, with sensitiv-
ities of 3 and 4 CFU/g, respectively, following an overnight enrich-
ment step ( Wang and others 2004). These 2 studies used melting
curve analysis to differentiate the 2 species.
The 1st use of molecular beacons in the food microbiology arena
was to detect E. coliO157:H7 in milk (McKillip and Drake 2000).
Molecular beacon technology has also been used to detect Sal-
monella in a variety of fresh fruits and vegetables (Liming and Bag-
what 2004), with the ability to detect 1 to 3 CFU/25 g in these prod-
ucts, and cut the detection time from 3 to 4 d for conventional
methods to 18 h.
Finally, hybridization probes have been used recently in a food
matrix. A real-time PCR study targetingSalmonella in raw andready-to-eat meat products provided a detection level of 1 to 10
CFU/g, markedly better than the 103 CFU/g obtained by the tradi-
tional culture and enzyme immunoassay (EIA) methods currently
used (Ellingson and others 2004). Total time for detection, including
a 6-h enrichment step, was 12 h; the EIA test requires 48 h to
achieve presumptive positive results. Because this study used
hybridization probes, confirmation of results could be achieved
with melting curve analysis.
Several commercially available real-time PCR assays targeting
foodborne pathogen detection have recently obtained Performance
Tested Methods status from the AOAC Research Institute. At the
time of this writing, these include the BAX System assays for L.
monocytogenes, Salmonella, and E. coliO157:H7 (Dupont Qualicon,
Inc., Wilmington, Del., U.S.A.), the Roche Diagnostics Lightcycler
Salmonella Detection Kit (Roche Applied Science, Indianapolis, Ind.,
U.S.A.), and, most recently, the Genevision Rapid Detection Systems
forE. coliO157:H7, Salmonella, L. monocytogenes, andListeria species
(Warnex Diagnostics, Laval, Quebec, Canada) (AOAC Intl. 2004). It is
important to note that each assay is approved only for specific food
matrices and as such may not be appropriate for all products. Also,
regulatory agencies such as USFDA, USDA, and AFNORgenerally re-
gard these as screening tests; presumptive positives must be fol-
lowed up with conventional detection methods.
TTTTTechnical challengesechnical challengesechnical challengesechnical challengesechnical challengesSelection of a target gene and development of specific primers
and probes are critical factors to achieve the desired detection spec-
http://www.ift.org/http://www.ift.org/http://www.ift.org/7/27/2019 Real-Time Polymerase Chain Reaction for the Food Microbiologist
4/5
R52 JOURNAL OF FOOD SCIENCEVol. 70, Nr. 3, 2005 URLs and E-mail addresses are active links at www.ift.org
R
C
i
R
i
iF
d S
i
Real-time PCR for the food microbiologist . . .
ificity. Targeting a gene highly conserved among different species
can be used for a broad-based detection strategy, while targeting a
DNA sequence unique to a particular species or strain can produce
a highly specific test. Specific primer and probe development nor-
mally involves 1st identifying a target gene based on the ultimate
goal of the detection and the understanding of the uniqueness of
biological functions of various macromolecules in the organisms.
Then DNA sequences of the target gene from various organisms
will be aligned. Two to three regions that are conserved within the
group of organisms to be detected, yet distinct from the back-
ground microflora, need to be identified. DNA primers and probe
will be derived based on these conserved sequences. The se-
quence composition and the relative positions of these oligonucle-
otides in the genome have to fulfill the technical requirements for
the specific detection chemistry, that is, the matching of the melt-
ing temperatures of the primers and probe, the lengths of the oli-
gonucleotides and the amplification products within the required
range, and so forth. The developed primers and probe further need
to be tested for detection specificity with real microorganisms. In
our lab, we were able to detect closely related thermophilic spoilage
organisms of both GeobacillusandAlicyclobacillusspp., using the
same set of primers and probe targeting a 16s rRNA gene sequence
(Connor and others 2005). However, detection specificity can be lostwhen a highly conserved region is used to design primers and
probes to detect a specific organism. One recent study detecting
environmental molds using species-specific primers and probes
found that a number of the assays also detected closely related
species (Haugland and others 2004). Because the DNA sequences
were not exact matches, the efficiency of the PCR reactions was
greatly diminished and high levels of the alternate organisms were
required to produce these false-positive signals. These examples
point out the importance of carefully selecting the DNA sequences
used to design primers and probes to achieve the desired results.
This can be particularly important in food samples that may con-
tain relatively high levels of background microflora.
Multiplexing is a preferred feature of real-time PCR, but thereare also limits in how many DNA sequences can be analyzed in a
given sample. Multiplexing can be performed with SYBR Green I
technologies using melting point analysis; however, a precise
knowledge of each amplicons melting point is needed, and the
melting points must be far enough apart to be distinguishable.
TaqMan assays rely on different colors of fluorescent markers for
multiplexing, but the colors must be widely separated in the visible
spectrum. Current commercial technologies can differentiate 3 or
4 colors of dye, but from a practical standpoint, up to 12 oligonucle-
otides (8 primers and 4 probes) need to be tested for compatibility,
and up to 4 PCR reactions need to be optimized for similar amplifi-
cation efficiencies to produce a reliable multiplexed reaction. Mo-
lecular beacons, scorpions, and hybridization probes can make use
of both melting curve analysis and different color fluorescence
during the same reaction because unlike the TaqMan probe, these
fluorescent probes are not cleaved (Bellin and others2001; Wittwer
and others 2001). The problems with optimization and multiple re-
action efficiencies, however, still remain.
Another key factor affecting PCR efficiency, both conventional
and real-time, is the DNA extraction technique. A study using
known amounts ofCryptosporidiumoocysts in fecal samples found
that using glass beads to disrupt cells and release the DNA provid-
ed 100% sensitivity, whereas using a freeze-thaw cycle with liquid
nitrogen provided only 83% sensitivity (Lindergard and others
2003). Cheng and Griffiths (2003) reported that the detection lev-
els ofCampylobacter jejuniin chicken carcass washes ranged from
104 to 102 CFU/mL, depending on which of the 5 different cell lysis
methods was used. We have used the commercially available
Qiagen DNeasy Tissue Kit (Qiagen, Valencia, Calif., U.S.A.) for DNA
extraction, and the detection of less than 100 cells/mL sample was
achieved.
A problem inherent to all PCR methods is the presence of factors
that inhibit nucleic acid synthesis by the polymerase enzyme. Such
inhibitory factors can be found in foods, culture media, and various
chemical compounds, including those used to extract DNA (Rossen
and others 1992), emphasizing the importance of careful sample
preparation. Adding substances that block these inhibitors has
been reported to improve detection sensitivities (Grant 2003). Us-
ing a control sample with a known amount of DNA can be used to
measure and adjust for reaction inhibition (Rijpens and Herman
2002).
Polymerase chain reactions also cannot distinguish between live
and dead cells. DNA can be rather resistant to degradation and may
be present for some time after the death of its host cell. This can be
a problem in a food matrix, where processing may destroy a bacte-
rial cell but leave its DNA relatively intact. Reverse-transcription
PCR (RT-PCR), which detects RNA rather than DNA, can overcome
this problem, but handling RNA is inherently more difficult than
DNA. RNase, the enzyme that digests RNA, is ubiquitous in the
environment, making RNA very short-lived unless great care is tak-en when extracting and handling it. Also, an extra step is needed to
convert the RNA to DNAthe reverse transcriptionbecause DNA
is the template needed for a PCR reaction. These factors make RT-
PCR somewhat impractical for a commercial food application.
Finally, food samples tend to be less homogeneous and contain
lower levels of target organisms than clinical samples, making
proper sampling essential. Rather than pushing the technical de-
tection limit of real-time PCRthat is, the ability to detect 1 cell in
1 mL or 1 g of sampleit is more meaningful to incorporate a short
enrichment procedure or to concentrate the target organism from
a relatively large sample size, thereby improving detection sensitiv-
ity and achieving accurate analysis of food samples. Filtration,
immunomagnetic bead capture, and centrifugation are methodsthat have been used to concentrate bacteria in diluted samples
and separate them from the food matrix (Fratamico 2001). As noted
in several of the previous examples, however, enrichment periods
and post-enrichment procedures for PCR analysis can be much
shorter than those needed for conventional methods because the
purpose here is just to have enough cells to ensure that at least 1
DNA template will be included in the PCR reaction (Jothikumar
and others 2003; Ellingson and others 2004; Liming and Bagwhat
2004).
Conclusions
S
tudies such as these point out the promise that real-time PCR
holds for the detection of foodborne pathogens and spoilage
microbes. An organism that previously took days or weeks to cul-
ture, isolate, and identify might now be detected in a matter of
hours. Reactions can be multiplexed so that several targets can be
detected in the same reaction, further reducing the time and labor
needed. The ability to run 96 or more samples simultaneously and
to see results without any post-amplification processing also
makes real-time PCR much more user-friendly than standard PCR.
With relatively brief enrichment, bacteria have been detected
down to a single CFU/g. This tremendous sensitivity can be partic-
ularly useful in finding zero tolerance organisms in food such as
E. coliO157:H7 and L. monocytogenes. And if there is a question as
to the viability of cells detected, real-time PCR can be used as a
rapid screening test, followed up by confirmation with conventional
methods for presumptive positives.
http://www.ift.org/http://www.ift.org/http://www.ift.org/7/27/2019 Real-Time Polymerase Chain Reaction for the Food Microbiologist
5/5
Vol. 70, Nr. 3, 2005JOURNAL OF FOOD SCIENCE R53URLs and E-mail addresses are active links at www.ift.org
R : C o n c i s e R e v i e w s i n F o o d S c i e n c e
Real-time PCR for the food microbiologist . . .
Real-time PCR still cannot completely replace conventional de-
tection methods because of its current technical and regulatory lim-
itations. However, with careful assay design and knowledge of these
limitations, it can be a powerful tool in food microbiology. Its abil-
ity to reduce the time to detect organisms can free up lab person-
nel to perform other tasks, increasing the throughput of laboratory
testing and the efficiency of quality assurance programs. Also, the
rapid screening of samples can allow earlier release of product, free-
ing valuable warehouse space and allowing food to be marketed
earlier in its shelf-life.
In conclusion, despite some limitations, real-time PCR shows
great promise as a tool for the food microbiologist to use in improv-
ing quality assurance and food safety. It can play a valuable role in
the rapid detection of pathogenic and spoilage organisms, and its
usefulness should only increase as the technology continues to
mature.
AcknowledgmentsThe authors thank Drs. Steve Schwartz and Ahmed Yousef for help-
ful discussions. The authors also acknowledge the Ohio Agricultural
Research and Development Center for providing partial funding for
the iCycler. Related research projects on real-time PCR detection
applications are sponsored by the Ohio State Univ. start-up fund,the Center for Innovative Food Technology, and the Center for
Advanced Food Processing and Packaging for author H.H. Wang.
The Wilbur A. Gould Departmental Fellowship offered partial sup-
port for author C.J. Connor. Author S.E. Hanna is sponsored by the
Dept. of Health Education and Training, Army Medical Dept. Cen-
ter and School, Fort Sam Houston, Texas.
ReferencesAllmann M, Hofelein C, Koppel E, Luthy J, Meyer R, Niederhauser C, Wegmulle r
B, Candrian U. 1995. Polymerase chain reaction (PCR) for detection of patho-genic microorganisms in bacteriological monitoring of dairy products. ResMicrobiol 146(1):8597.
AOAC Intl . 2004. Perf orman ce test ed metho ds. Gait hersb urg, Md.: AOAC Intl .Available from: http://www.aoac.org/testkits/testedmethods.html. Accessed 16
Nov 2004.Bagwhat A. 2003. Simultaneous detection of Escherichia coli O157:H7, Listeriamonocytogenesand Salmonella strains by real-time PCR. Int J Food Microbiol84(2):21724.
Bagwhat A. 2004. Rapid detection of Salmonella from vegetable rinse-waterusing real-time PCR. Food Microbiol 21(1):738.
Bellin T, Matthias P, Matussek A , Hempen HG, G unzer F. 2001. Rapid d etection o fenterohemorrhagic Escherichia coliby real-time PCR with fluorescent hybrid-ization probes. J Clin Microbiol 39(1):3704.
Bernard P, Wittwer C. 2000. Homogeneous amplification and variant detectionby fluorescent hybridization probes. Clin Chem 46(2):1478.
Campbell NA, Reece JB. 1996. DNA technology. In: Biology. 4th ed. New York:Benjamin/Cummings Publishing Co. p 36998.
Cheng Z, Griffiths M. 2003. Rapid detection of Campylobacter jejuni in chickenrinse water by melting-peak analysis of amplicons in real-time polymerasechain reaction. J Food Prot 66(8):134352.
Connor CJ, Luo H, McSpadden-Gardener BB, Wang HH. 2005. Development of areal-time PCR-based system targeting the 16S rRNA gene sequence for rapiddetection ofAlicy cloba cillus spp. in juice products. Int J Food Microbiol (Inpress).
Corless CE, Guiver M, Borrow R, Edwards-Jones V, Kaczmarski EB, Fox AJ. 2000.Contamination and sensitivity issues with a real-time universal 16S rRNAPCR. J Clin Microbiol 38(5):174752.
Ellingson JLE, Anderson J, Carlson S, Sharma VK. 2004. Twelve hour real-timePCR technique for the sensitive and specific detection of Salmonella in rawand ready-to-eat meat products. Mol Cell Probes 18(1):517.
Fratamico PM. 2001. Applications of the polymerase chain reaction for detec-tion, identification, and typing of foodborne microorganisms. In: Wilson CL,Droby S, editors. Microbial food contamination. New York: CRC Press. p 959.
Giulietti A, Overbergh L, Valckx D, Decallonne B, Bouillon R, Mathieu C. 2001. Anoverview of real-time quantitative PCR: applications to quantify cytokine geneexpression. Elsevier; Methods 25(4):386401.
Grant MA. 2003. Evaluation of methods to improve detection of Escherichia coliO157:H7 in fresh produce by polymerase chain reaction. J Food Prot 66(1):1824.
Haugland RA, Varma M, Wymer LJ, Vesper SJ. 2004. Quantitative PCR analysis ofselected Asperg illus, Penic illium and Paecilomyces species. Syst Appl Micro-biol 27(2):198210.
Hein I, Klein D, Lehner A, Bubert A, Brandl E, Wagner M. 2001. Detection andquantification of the iap gene ofListeria monocytogenesand Listeria innocuaby a new real-time quantitative PCR assay. Res Microbiol 152(1):3746.
Ibekwe AM, Watt PM, Grieve CM, Sharma VK, Lyons SR. 2002. Multiplex fluoro-genic real-time PCR for detection and quantification ofEscherichia coliO157:H7in dairy wastewater wetlands. Appl Environ Microbiol 68(10):485362.
Jaykus L. 2003. Challenges to developing real-time methods to detect pathogensin foods. ASM News 69(7):3417.
Jensen N, Whitfield FB. 2003. Role ofAlicyclobac illus acido terre stris in the de-velopment of a disinfectant taint in shelf-stable fruit juice. Lett Appl Microbiol36(1):914.
Jinneman KC, Yoshitomi KJ, Weagant SD. 2003. Multiplex real-time PCR methodto identify shiga toxin genes stx1 and stx2and Escherichia coli O157:H7/H-
serotype. Appl Environ Microbiol 69(10):632733.Jothikumar N, Wang X, Griffiths M. 2003. Real-time multiplex SYBR Green I-
based assay for simultaneous detection of Salmonella serovars and Listeriamonocytogenes. J Food Prot 66(11):21415.
Kaiser K, Rabodonirina M, Picot S. 2001. Real time quantitative PCR and RT-PCRfor analysis ofPneumocystis carinii hominis. J Microbiol Methods 45(2):1138.
Liming SH, Bagwhat A. 2004. Application of a molecular beacon-real-time PCRtechnology to detect Salmonella species contaminating fruits and vegetables.Int J Food Microbiol 95(2):17787.
Lindergard G, Nydam DV, Wade SE, Schaaf SL, Mohammed HO. 2003. The sensi-tivity of PCR detection of cryptosporidium oocysts in fecal samples using twoDNA extraction methods. Mol Diagn 7(34):14753.
Luo H, Yousef AE, Wang HH. 2004. A real-time polymerase chain reaction-basedmethod for rapid and specific detection of spoilage Alicyclo bacillus spp. inapple juice. Lett Appl Microbiol 39(4):37682.
Lyon WJ. 2001. TaqMan PCR for detection of Vibrio choleraeO1, O139, non-O1,
and non-O139 in pure cultures, raw oysters, and synthetic seawater. ApplEnviron Microbiol 67(10):468593.
Mackay I. 2004. Real-time PCR in the microbiology laboratory. Clin MicrobiolInfect 10(3):190212.
Makino SI, Cheun HI, Watarai M, Uchida I, Takeshi K. 2001. Detection of anthraxspores from the air by real-time PCR. Lett Appl Microbiol 33(3):23740.
Malinen E, Kassinen A, Rinttila T, Palva A. 2003. Comparison of real-time PCRwith SYBR Green I or 59-nucl ease as says and dot-blot hybridizatio n with rDNA-targeted oligonucleotide probes in quantification of selected faecal bacteria.Society for General Microbiology; Microbiology 149(1):26977.
McKillip JL, Drake M. 2000. Molecular beacon polymerase chain reaction detec-tion of Escherichia coliO157:H7 in milk. J Food Prot 63(7):8559.
Miller K, Smith R, Storts D. 1996. Improved PCR amplification using TaqBead hotstart polymerase. Promega Notes Magazine 60:25.
Missel A, Decker K, Loeffert D, Mueller S, Dwyer K, Kang J. 2001. Improvementsin quantitative PCR and RT-PCR using SYBR Green. Hilden, Germany: QIAGEN.Ava il ab le fr om : http://www1.qiagen.com/literature/posters/PDF/PCR_RTPCR_RNAamp/1016700_SPOS_RTPCR_0201.pdf. Accessed 19 May 2004.
Pierce KE, Rice JE, Sanchez JA, Brenner C, Wangh LJ. 2000. Real-time PCR usingmolecular beacons for the accurate detection of the Y chromosome in singlehuman blastomeres. Mol Hum Reprod 6(12):115564.
Ramos-Payan R, Aguilar-Medina M, Estrada-Parra S, Gonzalez-Y-Merchand JA,Favila-Castillo L, Monroy-Ostria A, Estrada-Garcia IC. 2003. Quantificationof cytokine gene expression using an economical real-time polymerase chainreaction method based on SYBR Green I. Scand J Immunol 57(5):43945.
Rijpens NP, Herman LM. 2002. Molecular methods for identification and detec-tion of bacterial food pathogens. J AOAC Int 85(4):98495.
Rodriguez-Lazaro D, Hernandez M, Esteve T, Hoorfar J, Pla M. 2003. A rapid anddirect real time PCR-based method for identification of Salmonella spp. J Mi-crobiol Methods 54(3):38190.
Rossen L, Norskov P, Holmstrom K, Rasmussen OF. 1992. Inhibitio n of PCR bycomponents of food samples, microbial diagnostic assays and DNA extractionsolutions. Int J Food Microbiol 17(1):3745.
Schmittgen TD, Zakrajsek BA, Mills AG, Gorn V, Singer MJ, Reed MW. 2000. Quan-titative reverse transcription-polymerase chain reaction to study mRNA decay:comparison of endpoint and real-time methods. Anal Biochem 285(2):194204.
Tyagi S, Kramer FR. 1996. Molecular beacons: probes that fluoresce upon hybrid-ization. Nat Biotechnol 14(3):3038.
[USFDA] U.S. Food and Drug Administration. 2001. 2001 Food Code. Washington,
D.C.: Food and Drug Administration. Available from: . Accessed 18 May 2004.
Vishnubhat la A, Obersh RD, Fung DYC, Wonglumsom W, Hays MP, Nagaraja TG.2001. Evaluation of a 5-nuclease (TaqMan) assay for the detection of virulentstrains of Yersinia enterocolitica in raw meat and tofu samples. J Food Prot64(3):35560.
Wang X , Jothikumar N, Griffiths M. 2004. Enrichment and DNA extraction proto-cols for the simultaneous detection of Salmonella and Listeria monocytogenesin raw sausage meat with multiplex real-time PCR. J Food Prot 67(1):18992.
Whitcombe D, Theaker J, Guy SP, Brown T, Little S. 1999. Detection of P CR productsusing self-probing amplicons and fluorescence. Nat Biotechnol 17(8):8047.
Wittwer CT, Herr mann MG, Gundry CN, Elenito ba-Johnson KS. 2001. Real-timemultiplex PCR assays. Elsevier; Methods 25(4): 43042.
http://www.ift.org/http://www.ift.org/http://www.aoac.org/testkits/testedmethods.htmlhttp://www1.qiagen.com/literature/posters/PDF/PCR_RTPCR_RNAamp/1016700_SPOS_RTPCR_0201.pdfhttp://www1.qiagen.com/literature/posters/PDF/PCR_RTPCR_RNAamp/1016700_SPOS_RTPCR_0201.pdfhttp://www1.qiagen.com/literature/posters/PDF/PCR_RTPCR_RNAamp/1016700_SPOS_RTPCR_0201.pdfhttp://www1.qiagen.com/literature/posters/PDF/PCR_RTPCR_RNAamp/1016700_SPOS_RTPCR_0201.pdfhttp://www.aoac.org/testkits/testedmethods.htmlhttp://www.ift.org/