Diurnal Studies of Methane in the London Region The use of mixing ratio and automated stable isotope measurements from a fixed site to evaluate sources. Rebecca Fisher, David Lowry, Srimathy Sriskantharajah and Euan G. Nisbet Department of Earth Sciences, Royal Holloway, University of London, - PowerPoint PPT Presentation
Citation preview
Diurnal Studies of Methane in the London Region
The use of mixing ratio and automated stable isotope measurements from a fixed
site to evaluate sources
Rebecca Fisher, David Lowry, Srimathy Sriskantharajah and Euan G. Nisbet
Department of Earth Sciences, Royal Holloway, University of London, Egham, Surrey, TW20 0EX, UK.
AGU Fall Meeting, 10th – 14th December 2007
Outline
• CH4 monitoring in the London region
• In situ CH4 stable isotopic analysis using CF-IRMS
• Diurnal studies of methane 13C
• Diurnal and seasonal variations in the methane source mix
• Implications for emissions inventory verification
Location of the Royal Holloway air monitoring site• 30 km WSW of centre of London, in Egham, Surrey• Air inlet 15 m above local ground, 45 m above London basin
Methane mixing ratio at Royal Holloway, Egham• CH4 mixing ratio monitored since 1995• Measured at 30-minute intervals using HP 5890 GC-FID, current precision
(±3 ppb)• Calibrated to the NOAA 04 scale• Decline of approximately 9 ppb/year over the last decade
Monthly mean CH4 mixing ratio in Egham
Mace Head
Egham
Comparison of methane mixing ratio at Egham and Mace Head
CH4 mixing ratio Egham – Mace Head (plotted by K. Masarie, NOAA)
Question:Question: Which sources have changed to drive the decrease in methane mixing ratio measured in SE England?
• Decline in the excess of CH4 mixing ratio in SE England’s air over Atlantic Mace Head air, on average -5.5 ppb/year.
• SE England methane emissions flux is growing more slowly than the background and appears to be decreasing in absolute terms.
• Larger changes occurred in the late 1990s. Since then, UK methane emissions appear to have been nearly static.
2003 anomaly –heatwave across Europe
London Atmospheric Emissions Inventory 2003
Methane Source Emission Tonnes/yr
Typical δ13C (‰)
Road transportGas consumption Industrial (gas)OilSewage
1315 1706112076 10 3608
-20 ± 4-37 ± 3 (North Sea gas)-37 ± 3
-57 ± 3
TOTAL 34070
Emissions data from LAEI, published by the Greater London Authority, 2006.
13C = [(Rsample-Rref)/Rref] x 1000 ‰ where R=13C/12C. C reference is V PDB.
Norlands Lane landfill site, 4 km from Royal Holloway• Another large source not included in the
inventory: Landfill site emissions, -53 ± 4‰.• Most landfills in the Greater London area are
now closed, but many continue to emit methane.
• Requires 60 litres of air per analysis.
• Offline combustion of CH4 followed by dual inlet mass spectrometry.
• Each analysis takes 2-3 hours to complete.• Data precision is very high, 0.03‰ repeatability.
Methane 13C Monitoring (I) Conventional Offline Extraction / Dual Inlet
Method
Methane extraction line
PRISM MS
Technique described in Lowe et al., JGR Atmos, 1991.
Methane 13C analysis (II) Continuous Flow GC IRMS
• Continuous flow techniques generally offer:• Smaller sample volume• Faster analysis time so higher sample throughput• Convenience of automation…but usefulness may be limited by the precision obtained.
• GV Instruments’ Trace Gas connected to IsoPrime Mass Spectrometer in continuous flow set-up.
• 75 mL of air for atmospheric samples.• 16 minute analysis time.• Changes made to automate inlet and
improve precision (repeatability) to 0.05‰ for CH4 13C analysis. See Fisher et al., Rapid Communications in Mass Spectrometry, 2006.
Automated valve inlet:
• Up to 3 tanks/sample bags can be connected up and automatically analysed.
• Or outside air pump connected and outside air analysed every 30 minutes.
Developments made to the Trace Gas at Royal Holloway
Furnace catalyst:
• Complete oxidation of CH4 to CO2 is a key step.
• Different catalysts tested.• High precision using palladium powder
on quartz wool catalyst at 790ºC.
Methane 13C monitoring – diurnal studies
• High CH4 mixing ratio recorded under inversion – typically still, anticyclonic conditions.
• Methane 13C measured at intervals throughout the night. Used to calculate the mixed source signature of regional sources.
• This technique has been used in other urban areas to assess CH4 sources, e.g. Heidelberg, Germany (Levin et al., 1999).
• Diurnal studies were carried out at Royal Holloway during events in 1996 – 1998. 22L SS tanks filled to 8 bar, collected at 2 hour intervals, analysed using offline extraction and dual inlet mass spectrometry (Lowry et al., JGR Atmos., 2001).
• Since 2003 the automated continuous-flow Trace Gas system has been used for diurnal studies.
Hot dry summer of 2003, high temperatures across Europe.
Wind direction from East to North-east (London direction).
Diurnal study 4th-5th August 2003
Keeling plot: Mean overnight source signature: -55.8 ± 0.7‰, i.e. dominated by biogenic sources.
Diurnal variation in source signature
Isotopically enriched methane coincides with morning and evening rush hours and times when domestic boilers would be turned on
Diurnal cycle of CH4 mixing ratio - background (2005)
13C source signature (2005 diurnals)
Seasonal variationMean overnight (22:00 – 06:00) 13C source signature during diurnal studies and mean monthly
CH4 mixing ratio recorded at Royal Holloway in 2005
• CH4 more depleted in 13C during the summer months - biogenic CH4 production higher.
• Enrichment in 13C during the autumn. Increased fossil fuel emissions.
Comparison between diurnal studies in 1996 and 2005
• Considering the London sector (45 to 110º):
• In 1996: mean CH4 13C source signature was -48.7 ± 0.3‰ (Lowry et al., 2001).
• In 2005: mean CH4 13C source signature was -50.1 ± 0.7‰.
• Likely to have been caused by a substantial decrease in emissions from gas leaks in recent years. This supports inventory estimates for
London (LAEI). • 1998 inventory: 45460 Tonnes/yr CH4 from natural gas.
• 2003 inventory: 29137 Tonnes/yr CH4 from natural gas.
Emissions inventory verification• 2003 LAEI inventory suggests a methane source signature of -35.9‰.
• From the diurnal studies:• 1996 measured value of -48.7‰ indicates source of 77% biogenic
(landfill/sewage) and 23% fossil fuel (e.g gas leaks).• 2005 measured value of -50.1‰ indicates source of 85% biogenic and
15% fossil fuel.
• If the source signature measured at Egham is typical of the source signature for London, then current inventory estimates are missing 167 kTonnes / year of biogenic source (e.g. landfill at -53‰).
• This is an overestimation: the Egham site is closer to some biogenic sources (local landfills and ruminants) than is typical of the London area - future diurnal studies in central London are planned to measure the central London methane source signature.
Quantifying regional methane emissions: the radon tracer method
• 222Rn, emitted at uniform rate from soils, builds up under inversion layer. Assume radon flux of 60 Bqm-2h-1
(mean flux for European soils – Eckhardt, 1990).
• Methane also builds up under the inversion – measure concentrations of 222Rn and CH4 → calculate the CH4 emission rate.
• Mean emission rate in 2005 calculated using this technique: 1.21 (± 0.69) g(CH4) km-2 s-1, equivalent to 94 ktonnes/yr for London.
• Higher than London inventory estimate of 34 kT/yr - could account for the missing biogenic source implied in isotope studies.
Correlation between CH4 and 222Rn, 10th to 12th August 2005
2005 monthly averages of CH4 emission rate calculated using the radon tracer method
Conclusions• Long-term monitoring of CH4 mixing ratio and 13C from a single well-placed site can
provide valuable insight into emissions from a region. • Results from the Royal Holloway site have highlighted the seasonal and diurnal
variability of CH4 sources in the London region and suggested that biogenic sources such as landfill sites have a larger influence on methane emissions than implied in the London Atmospheric Emissions Inventory.
• Reduction in methane emissions in the London region over the last decade appears to have been due to decreased emissions from gas leaks or other fossil fuel sources.
• The instrumentation has the capability of being run continuously to get a half hourly record of methane 13C. This could be useful at either a moderately polluted site to evaluate regional emissions, or combined with back trajectory analysis at a background site to consider changes in sources over a larger area.