Recent Application

on Regulation for

Ballast Water Treatment

in Ship Design

Recent Application

on Regulation for

Ballast Water Treatment

in Ship Design

General

• It is estimated that shipping transfers abt. 10 billion tones of ballast water each year around the world

•The invasion of foreign species through ship’sballast water is a world-wide economical and ecological threat

The IMO ConventionThe IMO Convention

• The International Maritime Organization (IMO) and other international bodies to take action to address the transfer of harmful organisms by ship’s ballast water.

• On February 13, 2004, IMO adopted a new convention (Control and Management of Ship’s Ballast Water and Sediment) in which ballast water exchange and/or ballast water treatment will be required on all vesselsoperating on routes with potential invasion risks.

1. Ballast Water ExchangeStandard(Regulation D-1)-- Tentative Measures until comply

with D-22. Ballast Water Performance

(treatment) Standard(Regulation D-2)--- Ballast Water

should be treated-- Not come into force yetAt the moment most new ships are following D-1 standard

Ballast Water Management procedures

D-1 Standard 1. Sequential method--- 95% of Ballast water from ballast tank discharge to overboard then filling clean deep sea water to the tank one by one.

---Limited by ship’s stability---For some kinds of ship, this method can’t be used, such as container vessel, multi-purpose vessel, RoRo vessel and PCTC vessel etc.

Ballast Water Exchange

2. Flow through (Over flow) Method ---Pumping through at least 3 times clean deep sea water to replace ballast water in ballast tanks---This technique is not effective in removing organisms from ballast water.There are some limitation in both methods

Ballast Water Exchange D-1 Standard

Otherwise, the Ballast Water which is replaced from ship to deep sea itself contribute to the wider dispersal of harmful species, and that island states located ‘down-stream’ of mid-ocean in Ballast Water Exchanging areas may be in particular risk from this practice

It is therefore extremely important to develop the effective ballast water treatment methods as soon as possible, in order to replace Ballast Water Exchange (D-1)

The problem for D-1 Standard

• The technology for ballast water treatment

1. Mechanical treatment methodssuch as filtration and separation

2. Physical treatment methodssuch as sterilization by ozone, inert gases, oxidation, ultra-violet light, electric currents and heat treatment

3. Chemical treatment methodssuch as adding biocides to ballast water to kill organisms

4. Various combinations of the above

Ballast Water treatment (D-2 )

ballast water treatment plant

RWO

Filter

Disinfection-Unit

CleanBallast! SYSTEMS

Flushing pump

ballast water treatment plant

Advanced Oxidation Technology

PureBallast System

Gas Super-saturation

ballast water treatment plant

NEIInert Gas

ballast water treatment plant

BOLLFILTER

Ballast Water Performance (D-2 )

Application date of DApplication date of D--22

in or after 2012

≥5000Between 2009 to 2011

??≤ 5000In or after 2009

≤1500 or ≥5000

1500~5000Before 2009

2018201720162015201420132012201120102009Ballast waterCapacity

(m3)

The date of ship construct

in or after 2012

≥5000Between 2009 to 2011

??≤ 5000In or after 2009

≤1500 or ≥5000

1500~5000Before 2009

2018201720162015201420132012201120102009Ballast waterCapacity

(m3)

The date of ship construct

Only BW treatment allowedOnly BW treatment allowed

Acc. to International Conventions, the application of D-2 come into force:12 months after ratification by 30 States and Whose fleets not less than 35% of world merchant shipping tonnage.Now It is ratified by 14 States which occupies 3.55% world shipping tonnage. So the application date will be delay about 2-3 years.Some Ship Owner have required to install the B.W. treatment system on the new ships

Ballast Water Performance (D-2 )

Question to Designer:

How to installthe B.W. treatment system

The problems of ballast water treatment for ship design

1. No many ballast water treatment systems can be selected.---Up to now, abt.15 systems are developed or under development---But only 3 systems have been approved by Administration/Class

2. Consideration of the treatment capacity and the size of equipment--- Generally the engine room space is limited, so the equipment size is very important

The problem of ballast water treatment for ship design

3. More electric power consumption--- Because of additional equipment such as back flushing pump, Disinfection-Unit, AOT Unit etc.

4. High price--- The price of the new equipment is very high, because it takes huge money and time in research and development. --- After more and more BW treatment plants used in the ship building, the price will be reduced.

Application of Ballast Water Treatment in Ship Design

Example

19100DWT MULTI-PURPOSEVESSEL

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

F.S.600 F.S.700 F.S.600F.S.700AP

NO.1 ANTIHEELING W.TK.( P&S)

NO.4 B.W.B.TK.( P&S)

F.P.TK.

BOSUN STORE

LOCKCHAIN

NO.2 CARGO HOLD

NO.1 CARGO HOLD

18900 86100 4200 29400 3600

BILGE W. TK.B.W.

S/T COOL.W.TK.

BO W THRU.

A.P.TK.

F.W.B.TK.( P&S)

S TEERING GEAR ROOM (C)

NO

.2 H

.F.O

.TK.

(P&

S)

F.W.TK.(P&S)

6600

NO.1 B.W.B.TK.

NO.2 S.W.B.TK.( P&S)

NO.1 S.W.B.TK.( P&S)

NO.4 ANTIHEELING W.TK.( P&S)

NO.4 LOW SUL.H.F.O.TK.( P&S)

NO.2 B.W.B.TK.( P&S)? ? ? ? ? ? ? ( ? &? )NO.5 B.W.B.TK.( P&S)NO.7 B.W.B.TK.( P&S)

7200

ROOM (C)

-5 0 105 2015 215 22025 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 225 230 235

PANAMA 1.0L

100

2900

2675

2675

2675

2300

2750

2600

2850

SOUND.LOG

FP

POOP DECK

A DECK

B DECK

C DECK

BRIDGE DECK

COMP. DECK

UPPER DECK

16950

19625

22300

24975

29950

32700

UPPER DECK

VOID

UPP ER PLATFORM 9550

LOWER PLATFORM 6500

20002400

4200

? ? ?

2500

2850

9500

8100

5800

CDGROMMET STORE

NO.3 S.W.B.TK.( P&S)

NO.2 ANTIHEELING W.TK.( P&S)

NO.4 S.W.B.TK.( P&S)NO.5 S.W.B.TK.( P&S)? ? ? ? ? ? ? ( ? &? )

NO.6 S.W.B.TK.( P&S)

NO.3 ANTIHEELING W.TK.( P&S)? ? ? ? ? ? ( ? &? )

9500

8100

11300

P8800S8250

9550

4200

(0)

NO

.1 H

.F.O

.TK.

(C)

(1) (2) (3) (4) (5) (6) (7) (8) (9) (11) (12) (13) (14) (15) (16) (17) (18) (1 9) (20)

NO.6 B.W.B.TK.( P&S) NO.3 B.W.B.TK.( P&S)

3500FLOOR? ?

No.2 D.O.STOR.TK.D.O

. SET

TL. T

K.

No.

1 D

.O. S

ERV.

TK

.

No.

2 D

.O. S

ER

V. T

K. H.F .O. SERV. TK.

? ? ?SLUDGE TK.

ENGINE ROOM

M/E L.O.SUMP TK.

CD

CD

CD

P

S

1400

ALL PANELS STACKED IN TWO STACK IN HOLD 2 FORE HOLD 1 PANELS STACKED

600

900

600

170

0.85D1959

2675

D DECK27650

273

229

544

NO.3 H.F.O.TK.( P&S)

BEAM

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

PRINCIPAL PARTICULARS

Length overall abt. 166.00 m

Breadth 22.90 m

Depth 13.90 m

draught (Scantling) 9.50 m

Capacity of water ballast tanks 9650 m3

Application Date for D-2 standard 2017

It is OwnerIt is Owner’’s requirement to install BW treatment plants requirement to install BW treatment plant

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

Reason:The new regulation will be come into force in the future for all ships---It is easier to install the B.W. treatment system for new vessel than the existing vesselThe vessel will be navigated in the special area that is very dirty --- Where there are a lot of mud and sand in the ballast water as well as organisms--- When the vessel navigate in that area for a few years, there are many sediment in the ballast tanks --- To be cleaning it

Acc. to the owner’s special requirements we select RWO CleanBallast! SYSTEMS in this vessel

RWO CleanBallast! SYSTEMS

Filter: 5m x 3m x 2m,Disinfection-Unit: 1.9m x 1.6m x 2.6mControl box:  1.8m x 0.8m x 2.2m

Flushing pump

Filter

Disinfection-Unit

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

Characteristic:Big filter with Flushing pumpBig filter---- means good filtration performance, but Big size and high discharge resistance (Pressure loss)

Flushing pump----If the pressure difference between filter’s inlet and outlet is higher than a certain value, the flushing pump will be automatic started to back washing the filter to keep filter cleaning.

So it is suitable for ship in dirty area.

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

PRINCIPAL PARTICULARS for RWO CleanBallast! SYSTEMS Number: 2 setsCapacity: 350m3/h (each) Filter 2 setsFlushing pump 2 sets

Capacity: 360 m3/h (each)Delivery pressure: 0.60 MPa Electric power consumption: 110 kW (each)

Disinfection-Unit 2 setsElectric power consumption: 20kW (each)

Total electric power consumption: abt. 130kWx2=260kWPressure loss: 0.08 MPaTotal price: One million USD

Filter

RWOSize: 5m x 3m x 2m

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

9

BWF03.01.1 BWF03.01.2 BWF03.01.3 BWF03.01.4

BWKA03.01.1 BWKA03.01.2 BWKA03.01.3 BWKA03.01.4

BWKA03.01.1 BWKA03.01.2 BWKA03.01.3 BWKA03.01.4

BWKH03.07.1 BWKH03.07.2 BWKH03.07.3 BWKH03.07.4

10 11 12

supportlevel

Filter

Disinfection-Unit

RWO

Size: 1.9m x 1.6m x 2.6m

19100DWT MULTI19100DWT MULTI--PURPOSE VESSELPURPOSE VESSEL

BWX04.01

BWKA04.11

BWKA04.10

BWKA04.11

BWR04.01

BWKA04.10

7

14

13

1. Mechanical filtration to remove suspended solids, sediments and certain organisms during ballasting

2. Disinfection to reduce the number of organisms before filling ballast water tanks

3. Second disinfection to reduce the number of organisms according to the future Performance Standard D2 at ballast water discharge

Filter disinfection

deballasting

to ballast water tanks

discharge to sea

Conception

1

2/3

RWO

From ballast tank

Algae Monitor

DisinfectionBallast tank

Discharge overboard Sea chest

FilterBallast waterpump

Flushing pump

Drain

Air vent

SYSTEM DRAWING

Ballast water treatment

SYSTEM DRAWING

ENGINE ROOM LAYOUT

19100DWT MPV

ENGINE ROOM LAYOUT

19100DWT MPV

The suitable capacity of total ballast water in shipUsing permanent ballast for some kind of ships in order to reduce the quantity of water ballast.--- For container vessel, Ro-Ro vessel, PCTC Vessel etc.at loading condition, part of ballast water is used to increase the stability. So we can use permanent ballast instead of this part of ballast water. Otherwise, the specific gravity of permanent ballast (steel,iron,stone and concrete etc.) is heavier than sea water. It’s better for ship’s stability.

The consideration of using ballast water treatment in ship design

Find suitable space for install B.W. treatment equipment---specially for existing vesselThe suitable capacity of ballast pump and Ballasting /de-ballasting time---for designing, the capacity of BW treatment plant should be minimized because it is related to the engine room space, electric power consumption, and the equipment price etc. So the ballast pump capacity may be reduced and Ballasting /de-ballasting time may be longer than before

The consideration of using ballast water treatment in ship design

Ozone Treatment Plant

On the superstructure

Inert Gas treatment plant NEI

In the double bottomon low wing tank

Inert Gas treatment plant

NEI

filtration treatment plant

In the engine room

filtration treatment plant

In the engine room

Filtration and Oxidation Treatment plantFiltration and Oxidation Treatment plant

FilterFilter

6.18 Ø750 DN400

500 m³/h 50µ

In operation 2003

Filtration and Oxidation Treatment Filtration and Oxidation Treatment plantplant

In the engine room

Filtration and Oxidation Treatment Filtration and Oxidation Treatment plantplantThe Benrad AOT (Advanced Oxidation Technology) unit

In the engine room

The pump delivery pressure increase--- Because of additional discharging resistance --- For new design ship, there is no problem, but for existing vessels, the original pump delivery pressure will be not enough for installing some kinds of BW treatment plant that has high additional resistance in the system. So the original ballast pumps should be replaced or other kinds of BW treatment plant with no high discharging resistance to be selectedMore electric power consumption---The power of Aux. engine may be increased--- It is a big problem for existing vessels

The consideration of using ballast water treatment in ship design

The above mentioned is only one example in our ship design process

There are many other different problems for different kinds of B.W. Treatment system. So we need study and develop these systems in the ship design to comply with the new regulation

We hope more and more Ballast Water Treatment plant will be approved by Administration or Class and can be used on ship

In the future, the Ballast Water Treatment plant will be easier to install on ship

CONCLUSION

THANKS