Page 2: Recognition manual 2014 issue 8

This guide is designed as an aid to recognising component parts andinstalling within Superdrug Pharmacy and associated areas

It is important that this guide is used only in accordance withSuperdrug’s site specific layout drawing

Recognition Manual 2014

Page 3: Recognition manual 2014 issue 8

Manual Contents

Delivery documentation Pages 2-3

Dispensary Pages 4-30• Contents Page 4

Consultation Room Pages 31-44Consultation Room Pages 31-44• Contents Page 31

Nurses Room Pages 45-59• Contents Page 45

Addicts Area Pages 60-67•Contents Page 60

MDS Room Pages 68-78•Contents Page 68

Page 1Recognition Manual 2014

Page 4: Recognition manual 2014 issue 8

Equipment Receipt

On receipt of the equipment thedriver will present a copy of thedelivery note which will recordall component parts deliveredin consignment.

It will also show, under“pending” any equipment to“pending” any equipment tofollow.

Delivery Note

Page 2Recognition Manual 2014

Page 5: Recognition manual 2014 issue 8

PALLET CONTENTS SHEET

Job Number and Store Name

456-055867

Looking forSpecific Items

Delivery To SUPERDRUG at :

37 High Street

Town

County

Post Code

Job Ref. Client Delivery Date

Each pallet delivered will have apallet contents sheet stuck topolythene packaging.

This sheet lists only what isincluded on the pallet andenables specific parts to befound more quickly. Job Ref. Client Delivery Date

10699 01/02/03

PALLET SIZE _______ PALLET 3_______OF_____12___

QTY SUPERDRUG Part No. Cardinal Part No. DESCRIPTION

1 D500BH C6930-00 Bottle Hopper

found more quickly.

Some pallets may have severalparts packed upon it especiallyif they are small.

Retain all pallet sheets forfuture reference untilconsignment has beenunpacked and checked off. 1 D500BH C6930-00 Bottle Hopperunpacked and checked off.

PICKED/PACKED BY ___________________________ DATE ___________________

CHECKED BY _________________________________ DATE ___________________

Pallet Contents Sheet

Page 3Recognition Manual 2014

Page 6: Recognition manual 2014 issue 8

Dispensary Contents

Part no. Description Page

Typical overview part 1 5Typical overview part 2 6CDC500 Controlled Drugs Cabinet 11CDC760 Controlled Drugs Cabinet 11CDC570 Controlled Drugs Cabinet 11D00BE Bookends 7

Part no. Description Page

D600TEP Tall End Panel 19D650TBC Tall Boxed Corner 20D760AZE A-Z Medicine Storage Extension Module 21, 22D760AZS A-Z Medicine Storage Starter Module 21, 22D760FSE Finished Scripts Extension Module 23, 24D760FSS Finished Scripts Starter Module 23, 24D00BE Bookends 7

D00CM Conical Measure Holder 9D00PS Paper Shredder 25D00RXC RX Cupboard 30D00SBW Splash Back Wall Unit 9D400BN Bin Cupboard inc PVC bin 10D500BH Bottle / Carton Hopper 12D500BSU Bottle Rack & Sink Unit 13D500DP Doop Unit Small 14D500OP Open Shelf Unit 15

D760FSS Finished Scripts Starter Module 23, 24D760UEC Universal End Drawer Cover 24D900NB Notice Board 25D1000ASS Adjustable Spur MFC Shelves 250 & 300mm 7,8D1000DP Doop Unit Large 26D1000GW Grey Worktop (Pill Accuracy Check) 27D1000OP Open shelf unit 28D1020COP Corner Open Shelf Unit 29D1500EM Ergo Mat 25D3000WW White Worktop 27D500OP Open Shelf Unit 15

D500RX Prescription Storage 16D550UBC Under Worktop Boxed Corner 17D550UEP Under Worktop End Panel 17D600IT IT Unit 18

D3000WW White Worktop 27DCN0B Waste Bin 10DCN0WHS Wall Mounted Hand Sanitiser 9DCN0WPT Wall Mounted Paper Towel Dispenser 9

Page 4Recognition Manual 2014

Page 7: Recognition manual 2014 issue 8

D1

00

0G

W

D3

00

0W

W

D1

00

0A

SS

D3

00

0W

W

D5

00

RX

D5

00

OP

D4

00

BN

D6

00

IT

D5

00

BH

D1

50

0EM

CD

C5

00

D6

50

TBC

D600TEP

D4

00

BN

Typical Dispensary OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units

Page 5

D5

00

OP

D4

00

BN

D5

00

BH

D1

50

0EM

D6

50

TBC

Recognition Manual 2014

D4

00

BN

Page 8: Recognition manual 2014 issue 8

D3

00

0W

W

Site specific lockable gate in white MFC.Please refer to Project Manager for details

D1000GW

D3

00

0W

W

D7

60

AZE

D7

60

AZS

D7

60

FSS

D6

50

TBC

D7

60

AZE

D7

60

AZE

D7

60

AZE

Typical Dispensary OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units

Page 6

D7

60

AZE

D7

60

AZS

D7

60

FSS

D6

50

TBC

Recognition Manual 2014

D7

60

AZE

D7

60

AZE

D7

60

AZE

Page 9: Recognition manual 2014 issue 8

Adjustable Spur MFC Shelves

Critical Dimensions990(w) x 250(d) x18(h) mm per shelf990(w) x 250(d) x18(h) mm per shelfSent to site as a set of 5no shelves,2no 710mm spur uprights & 5nopairs of 200mm brackets.

Note:- A deeper 300mm shelf maybe specified for the dispensary“back of house” area and shouldbe fixed in accordance with thelayout drawing.

710mm

layout drawing.

D00BEIf Bookends are specifiedleave loose on spurshelves for use bypharmacy team.

Recognition Manual 2014 Page 7

Part no D00BE - BookendsPart no D1000ASS - Adjustable Spur MFC Shelves

Page 10: Recognition manual 2014 issue 8

1234566789

1011121314151516171819202122

Installation Detail•Set Spur 150mm above the worktopto allow space for low level (90mm)electrical trunking.•Set low level trunking flush withworktop to allow a 60mm gapbetween top of trunking and the 90mm electrical

150mm fromworktop tounderside ofbetween top of trunking and the

underside of the bottom spur shelf.•Space brackets as per set out tothe right. Start at the bottom andleave three clear spaces betweenbrackets.•Make allowances for IT Monitorswhen setting out on site.•Use appropriate wall fixings.

90mm electricaltrunking

underside ofspur post

Recognition Manual 2014 Page 8

Part no D1000ASS - Adjustable Spur MFC Shelves

Page 11: Recognition manual 2014 issue 8

CT34069 Paper Towel Dispenser290(w) x 145(d) x 265(h) mmNB Key to open dispenser isincluded and should be handedto Pharmacy manager.

DCN0WHS Wall MountedHand Sanitiser

156(w) x 96(d) x 265(h) mm

D00SBW – Splash Back Wall unit

Critical Dimensions990(w) x 12(d) x 600(h) mm

Installation Detail•Use appropriate fixings or gripfill to fix splash backabove bottle rack & sink unit.•Seal joint with white silicon.

Part no D00CM Conical Measure HolderPart no D00SBW Splash Back Wall Unit D00CM Conical Measure Holder

•Seal joint with white silicon.•Add ancillary items to positions indicated onelevation.

Part no D00SBW Splash Back Wall UnitPart no DCN0WHS Wall Mounted Hand SanitiserPart no DCN0WPT Wall Mounted Paper Towel Dispenser

Recognition Manual 2014

D00CM Conical Measure Holder370(w) x 150(d) x 200(h) mm

Page 9

Page 12: Recognition manual 2014 issue 8

910mm

Critical Dimensions400(w) x 520(d) x 920(h) mm

Installation Detail

•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wall

Capacity: 39 LitresDimensions: 380(w) x 280(d) x500(h) mm

520mm400mm

Part no. D400BN Bin Cupboard including pvc binPart no. DCN0B Waste Bin

Recognition Manual 2014

•A void to rear of unit and wallallows for plumbing etc.

Page 10

500(h) mm

Page 13: Recognition manual 2014 issue 8

N.B. Cabinets are only to be fixed to concrete floor or structural wall with rag bolts.Where the pharmacy is on a raised floor create suitable groundings directly toactual flooring.actual flooring.

CDC500500(w) x 450(d) x 850(h)

CDC570570(w) x 200(d) x 520(h)

CDC760760(w) x 305(d) x 865(h)500(w) x 450(d) x 850(h)

Floor fixed570(w) x 200(d) x 520(h)Wall fixed

760(w) x 305(d) x 865(h)Floor/Wall fixed

The Misuse of Drugs Act stipulates that a safe or cabinet shall be rigidly and securely fixed to a wall or floor by means of atleast two rag bolts each passing through an internal anchor plate of mild steel which is at least 3mm thickness and which has a

surface area of at least 19355 square millimetres.

Part no CDC500 Controlled Drugs CabinetPart no CDC570 Controlled Drugs CabinetPart no CDC760 Controlled Drugs Cabinet

Recognition Manual 2014 Page 11

Page 14: Recognition manual 2014 issue 8

910mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

NoteTop two drawers havedividers for cartons.

910mm

500(w) x 520(d) x 910(h) mm

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop•A void to rear of unit and wallallows for plumbing etc.

520mm500mm

Part no D500BH Bottle / Carton Hopper

allows for plumbing etc.

Recognition Manual 2014 Page 12

Page 15: Recognition manual 2014 issue 8

Critical Dimensions500(w) x 520(d) x 910(h) mm500(w) x 520(d) x 910(h) mm

910mm

520mm500mm

566mmInstallation Detail•Cut hole in back to allowaccess to plumbing .•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wall

NoteBottle rack is removable toallow access to waste & waterheater.

Sink SpecUniversally Handed Space Saver -620 x 500 mm.

Tap SpecMixer Elbow tap

520mm566mm

206mm

448mm

Part no D500BSU - Bottle Rack & Sink Unit

Recognition Manual 2014

•A void to rear of unit and wallallows for plumbing etc.

Page 13

Mixer Elbow tap

Page 16: Recognition manual 2014 issue 8

910mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

Note

Installation Detail

•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wall

520mm500mm

Part no D500DP - Doop Unit Small

Note1no adjustable shelf toeach unit.

Recognition Manual 2014

•A void to rear of unit and wallallows for plumbing etc.

Page 14

Page 17: Recognition manual 2014 issue 8

910mm

Critical Dimensions

NoteIncludes 3no adjustableshelves.

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.

520mm500mm

Part no. D500OP - Open Shelf Unit

Critical Dimensions500(w) x 520(d) x 910(h) mm

Recognition Manual 2014

allows for plumbing etc.

Page 15

Page 18: Recognition manual 2014 issue 8

910mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

Note•Suited locks to full range, eachdrawer has binning strip withacrylic dividers.•Dividers to three top drawers.

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.

520mm500mm

Part no. D500RX - Prescription Storage

Recognition Manual 2014

allows for plumbing etc.

Page 16

Page 19: Recognition manual 2014 issue 8

Critical Dimensions550(w) x18(d) x 920(h) mm

Under Worktop End Panels

Installation Detail•Use top & bottom Uchannel or appropriatefixings to fix to end unit.

920mm

Critical Dimensions550(w) x 550(d) x 920(h) mm

Installation Detail•Use appropriate fixings to fix U channel to underside of

Under Worktop Boxed Corner

550mm

550mm

•Use appropriate fixings to fix U channel to underside ofworktop and floor.•Position first top & bottom U channels 530mm fromwall.•Position second set 550mm from adjacent wall.•Panels are supplied oversized so that they can bescribed to fit.•Slide panels into position and cover front corner withwhite PVC angle trim.

550mm

920mm

Part no. D550UBC - Under Worktop Boxed CornerPart no. D550UEP - Under Worktop End panels

Recognition Manual 2014 Page 17

550mm

Page 20: Recognition manual 2014 issue 8

910mm

Critical Dimensions

NoteCut out to rear to enablecabling.

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•Void to rear of unit and wallallows for plumbing etc.

520mm

600mm

Part no. D600IT - IT Unit

Critical Dimensions600(w) x 520(d) x 910(h) mm

Recognition Manual 2014

allows for plumbing etc.

Page 18

Page 21: Recognition manual 2014 issue 8

D600TEP Tall End Panel

Critical DimensionsCritical Dimensions600(w) x 18(d) x 2100(h) mm

Installation Detail•Panel has pre-drilled holes for fixing to perimeter post.•Use appropriate fixings to fix end panel to perimeterpost.•Use white screw caps to cover any visible screws.•Seal joint to wall with white silicon.

Part no. D600TEP – Tall End Panel

Page 19Recognition Manual 2014

Page 22: Recognition manual 2014 issue 8

Critical Dimensions650(w) x 650(d) x 2400(h) mm

2400mm

Installation Detail

•Create boxed corner from 50mm x 50mm softwood andwhite MFC panels supplied.•Use appropriate fixings to fit softwood to walls.•Use appropriate fixings to fix panels into position andcover front corner with white PVC angle trim.•Use white screw caps to cover any visible screws.

Part no. D650TBC – Tall Boxed Corner

•Use white screw caps to cover any visible screws.•If ceiling height exceeds 2400mm cut wall batons fromsoftwood provided and fix to wall to take lid.

Recognition Manual 2014 Page 20

650mm650mm

Page 23: Recognition manual 2014 issue 8

Part no. D760AZS - A-Z Medicine Starter Module

Part no. D760AZE - A-Z Medicine Extension Module

CautionIt is vital that system posts are installed in astraight line, vertical and level and fixed at 2nopoints on each individual post utilising suppliedadjustable wall fixing brackets

Recognition Manual 2014 Page 21

Site specific lockable gate in white MFC.Please refer to Project Manager for details

Page 24: Recognition manual 2014 issue 8

1. Erect frame of perimeterlegs and tie bars usingM10x50mm bolts, washersand nuts. Use 3no tie barsper module.per module.

The tie bars are handed soensure bar faces front onbrackets.

Do not over tighten.

2. Use adjustable feet to level

3. Use two wall fixingbrackets per upright, at alltimes using appropriatefixings to ensure posts areflush with each other.

Front

2. Use adjustable feet to levelframe.

flush with each other.

Critical Dimensions 760(w) x 610(d) x 2100(h) mm

7. Fit pull out shelves into postsstarting at bottom. The bottom shelfto occupy notches 11 & 13. Leave2no empty notches between eachsubsequent shelf.

6. Slide into position baseplinth drawers.

4. When all of the posts are inposition screw on the baseplinth covers.

5. Hang back panelson to tie bars.

Critical Dimensions 760(w) x 610(d) x 2100(h) mm

Recognition Manual 2014

Part no. D760AZS - A-Z Medicine Starter Module

Part no. D760AZE - A-Z Medicine Extension Module

Page 22

Page 25: Recognition manual 2014 issue 8

Part no. D760FSS Finished Scripts Starter Module

Part no. D760FSE Finished Scripts Extension Module

CautionIt is vital that system posts are installed in astraight line, vertical and level and fixed at 2nopoints on each individual post utilising suppliedadjustable wall fixing brackets

Page 23Recognition Manual 2014

Site specific lockable gate in white MFC.Please refer to Project Manager for details

Page 26: Recognition manual 2014 issue 8

1. Build frame as in A-Zmodules but use “L” shapedposts rather than “h” shapedposts.

2. Start at bottom and fit2. Start at bottom and fitdeep drawers into lowestpossible notches.

3. Fit lower pull out shelfinto notch 41 and thenleave 3no. notchesbetween each shelf above.

4. Fit opal acrylic fronts to5no. Pull out shelves.

D760UEC Universal End Drawer Cover1. Use Universal End Drawer cover on proceeding A-Zmodule if Finished Scripts module is part of same run.

Part no. D760FSS Finished Scripts Starter Module

Enablestransition fromA-Z “h” leg toFinished scripts“L” leg.

Critical Dimensions 760(w) x 610(d) x 2100(h) mm

Recognition Manual 2014

Part no. D760FSS Finished Scripts Starter ModulePart no. D760FSE Finished Scripts Extension ModulePart no. D760UEC Universal End Drawer Cover

Page 24

Page 27: Recognition manual 2014 issue 8

D900NB – 900 x 600mmNotice board to be fixed usingappropriate fixings whereindicated on layout drawing –landscape or portrait.

D1500EMErgo mat to be loose laid asindicated on layout drawing.

D00PSPaper Shredder to be placedwhere indicated on layout

Part no D900NB - Notice BoardPart no D1500EM - Ergo MatPart no D00PS - Paper ShredderRecognition Manual 2014 Page 25

where indicated on layoutdrawing.

Page 28: Recognition manual 2014 issue 8

910mm

Installation Detail

Critical Dimensions1000(w) x 520(d) x 910(h) mmNote

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.

520mm

1000mm

Part no D1000DP - Doop Unit Large

Note1no adjustable shelf.

Recognition Manual 2014 Page 26

Page 29: Recognition manual 2014 issue 8

Accuracy Checking Area Worktop

The accuracy checking area is a grey worktop

Critical Dimensions1000(w) x 600(d) x 30(h) mm

The accuracy checking area is a grey worktop

Critical Dimensions3000(w) x 600(d) x30(h) mm

White worktops

Installation Detail•Cut to appropriate length as required on site.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for all corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to unitsunderneath.

3000(w) x 600(d) x30(h) mm

Installation Detail•Where indicated on layout drawing fit grey worktop.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for any corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to units underneath.•Seal joint to wall with white silicon.

Part no D1000GW - Grey WorktopPart no D3000WW - White Worktop

underneath.•Seal joint to wall with white silicon.

Page 27Recognition Manual 2014

Page 30: Recognition manual 2014 issue 8

910mm

NoteIncludes 3no adjustableshelves.

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc. Critical Dimensions

520mm

1000mm

allows for plumbing etc.

Part no. D1000OP - Open Shelf Unit

Critical Dimensions1000(w) x 520(d) x 910(h) mm

Page 28Recognition Manual 2014

Page 31: Recognition manual 2014 issue 8

Critical Dimensions1020(w) x 1020(d) x 910(h) mm1020(w) x 1020(d) x 910(h) mm

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.

910mm

1020mm1020mm

Part no. D1020COP - Corner Open Shelf Unit

Page 29Recognition Manual 2014

1020mm

Page 32: Recognition manual 2014 issue 8

Recognition Manual 2014 Page 30

Part no. D00RXC - RX Cupboard

Page 33: Recognition manual 2014 issue 8

Consultation Room Contents

Part no. Description Page

Typical overview 32CN00LH Leaflet Holder with Magnetic Panel 33CN377DDP Drop Down Desk c/w PC Housing 34CN500DCU Drawer & Cupboard Unit 35CN500LSC Lockable Storage Cupboard 36CN500PFU Printer Shelf (Pull out) & Filing Unit 37

Part no. Description Page

CN00CS Child Seat 43CN00HM Height Measure – Wall mounted 43CN00MT Mixer Tap 42CN00S Sink 42CN00SF Sharps Flap 42CN00WA Chair without Arms – Green 43CN500PFU Printer Shelf (Pull out) & Filing Unit 37

CN500WLH Wall Mounted Cupboard L/H 38CN500WOS Wall Mounted Open Shelves 39CN500WRH Wall Mounted Cupboard R/H 38CN926WD Consultation Room Door 40CN2000SB Brushed Laminate Splash Back 41CN2000PCB Plinth Cover to Cons Room Base Units 42CN00A Chair with Arms – Green 43

CN00WA Chair without Arms – Green 43CN00WGD Wall Mounted Glove Dispenser 41CN00WS Weighing Scales 43D3000WW White Worktop 42DCN0B Waste Bin 35DCN0WHS Wall Mounted Hand Sanitiser 41DCN0WPT Wall Mounted Paper Towel Dispenser 41AA500AH Addicts Hatch 44

Page 31Recognition Manual 2014

Page 34: Recognition manual 2014 issue 8

CN

50

0W

RH

CN

50

0P

FU

CN

50

0W

OS

CN

50

0W

LH

CN

50

0W

LH

CN

00

LH

CN

50

0W

RH

CN

50

0P

FU

CN

50

0W

OS

CN

50

0W

LH

CN

50

0W

LH

CN00SF

AA500AH

CN

20

00

SB

CN00SF

CN

50

0LS

C

CN

20

00

SB

CN377DDP

D3

00

0W

W

CN

20

00

PC

B

CN

50

0D

CU

Contractors must ensure that all partition wallsthat make up a consultation room have adequate

sound provision. Fill void with Rockwool orsimilar material. Also lay above suspended

Typical Consultation Room OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units

Page 32Recognition Manual 2014

similar material. Also lay above suspendedceiling but consult with Project Manager first to

check that there are no asbestos issues

Page 35: Recognition manual 2014 issue 8

Critical Dimensions1000(w) x 5(d) x 800(h) mm

Installation Detail•Use appropriate fixings to fixto wall as indicated on layoutSuperdrug drawing.

Recognition Manual 2014 Page 33

Part no CN00LH Leaflet Holder with magnetic panel

Superdrug drawing.

Page 36: Recognition manual 2014 issue 8

Power and data sockets to befixed inside desk

750mm

Critical Dimensions600(w) x 377(d) x 750(h) mm

PANIC ALARM & RESETBUTTON - Site electrician toposition BOTH inside top cornerof unit

377mm600mm

Closedend

Openend

600(w) x 377(d) x 750(h) mm

Installation Detail•Position top to ensure openend faces wall units and closedend faces patient.•Use appropriate fixings to fixto wall.•To change handing remove topand rotate 180*.

of unit

Part no CN377DDP Drop Down Desk

and rotate 180*.

Recognition Manual 2014 Page 34

Page 37: Recognition manual 2014 issue 8

Critical Dimensions500(w) x 520(d) x 910(h) mm

910mm

Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.

Cupboard can beused for Clinical

520mm

Part no CN500DCU Drawer & Cupboard Unit

Recognition Manual 2014

used for Clinicalbin.

Page 35

500mm

Page 38: Recognition manual 2014 issue 8

910mm

Critical Dimensions500(w) x 520(d) x910(h) mm

Installation Detail

•Level using adjustable feet.

520mm500mm

•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.•If Needle Exchange chute isrequired cut worktop usingchute as a template.•For Sharps Flap specificationplease see page 34.

•Waste Bin to stand inside one of thelockable storage cupboards.•Yellow Needle bin supplied by LocalAuthority.

CN500LSC Lockable Storage CupboardDCN0B Waste Bin

Recognition Manual 2014 Page 36

Page 39: Recognition manual 2014 issue 8

Back of unit is open to allow accessto power and data sockets.to power and data sockets.

500mm

910mm

Critical Dimensions

Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits. 520mm

Part no CN500PFU mm Printer & File Unit

Critical Dimensions500(w) x 520(d) x 910(h) mm

Recognition Manual 2014 Page 37

Page 40: Recognition manual 2014 issue 8

600mm

350mm

600mm

500mm

Critical Dimensions600(h) x 500(w) x350(d) mmInstallation Detail

•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.

Critical Dimensions500(w) x 350(d) 600(h) mm

Part no CN500WLH Wall Cupboard L/HPart no CN500WRH Wall Cupboard R/H

Recognition Manual 2014 Page 38

Page 41: Recognition manual 2014 issue 8

600mm

Installation Detail•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.

Critical Dimensions500(w) x 350(d) 600(h) mm 350mm

500mm

Part no CN500WOS Wall Mounted Open Shelves

Recognition Manual 2014

screws.

Page 39

Page 42: Recognition manual 2014 issue 8

Cross logo suppliedby signage contractor

Critical DimensionsCritical Dimensions926(w) x 45(d) x 2040(h) mm

Installation Detail

•Sent to site without blind orhinges attached (but supplied)to enable door to be handed onsite.site.

•Door is supplied withundercoat. Top coat must beadded on site.

•Fix blind to rear of door usingappropriate fixings.

•Fix door hook to rear of door

Part no CN926WD Consultation Room Door

•Fix door hook to rear of doorcentralised at 1600mm high.

Recognition Manual 2014 Page 40

Page 43: Recognition manual 2014 issue 8

Splash Back

DCN0WPT Paper TowelDispenser 290(w) x 145(d) x265(h) mmNB Key to open dispenser isincluded and should be handed

DCN0WHS Wall MountedHand Sanitiser

156(w) x 96(d) x 265(h) mm

Critical Dimensions2000(w) x 18(d) x 550(h) mm

Installation Detail•Use appropriate fixings orgripfill to fix splash back.

Splash BackPre Laid Brushed AluminiumMDF.

included and should be handedto Pharmacy manager.

Part no CN2000SB Splash Back

gripfill to fix splash back.•Add ancillary items to positionsindicated on elevation.•Please ensure that there isenough clearance above toweldispenser to allow with openingkey.

CN00WGD Dispenser 270(w) x95(d) x 100mm (h)

Part no CN2000SB Splash BackPart no CN00WGD Wall Mounted Glove DispenserPart no DCN0WHS Wall Mounted Hand SanitiserPart no DCN0WPT Paper Towel DispenserRecognition Manual 2014 Page 41

Ensure cables to pc arecarried though partitionwalls

Page 44: Recognition manual 2014 issue 8

Installation Detail

•Cut worktop to length.•Edge any exposed ends.•Fit to top of base units using appropriate fixings.•Fit to top of base units using appropriate fixings.•Cut hole for sink and mixer tap as indicated on layoutdrawing.•Cut hole for Sharps flap if required.•Fix plinth to base units using gripfill or appropriatefixings.

Part no D3000WW WorktopPart no CN00S Sink

CN2000PCBBrushed Aluminium Laminate

CN00SF Sharps Flap fittingdetail

Part no CN00S SinkPart no CN00MT Mixer TapPart no CN00SF Sharps FlapPart no CN2000PCB Plinth to Base Unit

Brushed Aluminium Laminatefaced mdf plinth 2000(w) x100(h) x 18(d) mm

Page 42Recognition Manual 2014

Page 45: Recognition manual 2014 issue 8

Installation Detail

•Position all ancillary items as

Part no CN00WA Chair without Arms

•Position all ancillary items asper layout drawing.•Use appropriate fixings to fixheight measurer to wall.

Part no CN00A Chair with ArmsPart no CN00HM Height measurerPart no CN00WS Weighing scalesPart no CN00CS Child Seat

Page 43Recognition Manual 2014

Page 46: Recognition manual 2014 issue 8

Installation Detail

•Cut opening in partition wall asindicated on layout drawing and addtimber studs and noggins wherenecessary to take hatch fixings.•The bottom of the opening shouldbe 1200mm above floor.be 1200mm above floor.•Insert hatch into opening and useappropriate fixings to secure.•Fit shroud to reverse usingappropriate fixings.

Note•Liaise with electrical contractor toensure cable feed for bell push is

Recognition Manual 2014 Page 44

Part no AA500AH Addicts Hatch

ensure cable feed for bell push isaccessible.

Page 47: Recognition manual 2014 issue 8

Nurses Room Contents

Part no. Description Page

Typical overview 46CN400LSC Lockable storage cupboard 47CN500DCU Drawer & Cupboard Unit 48CN500LSC Lockable Storage Cupboard 49CN500PFU Printer Shelf (Pull out) & Filing Unit 50CN500WLH Wall Mounted Cupboard L/H 51

Part no. Description Page

CN00LH Leaflet Holder Panel 57CN00WA Chair without Arms – Green 56CN00WGD Wall Mounted Glove Dispenser 54CN00WS Weighing Scales 56D3000WW White Worktop 55DCN0B Waste Bin 49CN500WLH Wall Mounted Cupboard L/H 51

CN500WOS Wall Mounted Open Shelves 52CN500WRH Wall Mounted Cupboard R/H 51CN926WD Consultation Room Door 53CN2000SB Brushed Laminate Splash Back 54CN2000PCB Plinth Cover to Cons Room Base Units 55CN00A Chair with Arms – Green 56CN00CS Child Seat 56CN00HM Height Measure – Wall mounted 56CN00MT Mixer Tap 55

DCN0B Waste Bin 49DCN0WHS Wall Mounted Hand Sanitiser 54DCN0WPT Wall Mounted Paper Towel Dispenser 54N00CC Curtain Cubicle 58N00CCR Curtain Rail 58N00CR Couch Rolls 58N00CWA Nurses Desk Chair with Arms 59N00EC Examination Couch 58N500WM Wall Mirror 59N1200DK Desk to Nurses Room 59CN00MT Mixer Tap 55

CN00S Sink 55CN00SF Sharps Flap 55

N1200DK Desk to Nurses Room 59

Page 45Recognition Manual 2014

Page 48: Recognition manual 2014 issue 8

CN

92

6W

DC

N9

26

WD

N0

0C

C

N0

0EC

Contractors must ensure that all partition wallsthat make up a consultation room have adequate

sound provision. Fill void with Rockwool orsimilar material. Also lay above suspended

ceiling but consult with Project Manager first tocheck that there are no asbestos issues

Typical Nurses Room OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units

Page 46Recognition Manual 2014

check that there are no asbestos issues

Page 49: Recognition manual 2014 issue 8

910mm

Installation Detail

•Level using adjustable feet.

520mm

400mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.•If Needle Exchange chute isrequired cut worktop usingchute as a template.•For Sharps Flap specificationplease see page 34.

•Waste Bin to stand inside one of thelockable storage cupboards.•Yellow Needle bin supplied by LocalAuthority.

CN400LSC Lockable Storage CupboardDCN0B Waste Bin

Recognition Manual 2014

Authority.

Page 47

Page 50: Recognition manual 2014 issue 8

Critical Dimensions910mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.

Cupboard can beused for Clinicalbin.

Part no CN500DCU Drawer & Cupboard Unit

Recognition Manual 2014 Page 48

520mm500mm

Page 51: Recognition manual 2014 issue 8

910mm

Critical Dimensions500(w) x 520(d) x 910(h) mmInstallation Detail

•Level using adjustable feet.

520mm500mm

•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.•If Needle Exchange chute isrequired cut worktop usingchute as a template.•For Sharps Flap specificationplease see page 34.

•Waste Bin to stand inside one of thelockable storage cupboards.•Yellow Needle bin supplied by LocalAuthority.

CN500LSC Lockable Storage CupboardDCN0B Waste Bin

Recognition Manual 2014 Page 49

Page 52: Recognition manual 2014 issue 8

PANIC ALARM and RESET BUTTON-Site electrician to position to inside of

Back of unit is open to allow accessto power and data sockets

Site electrician to position to inside ofpedestal

910mm

Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.

520mm500mm

Part no CN500PFU mm Printer & File Unit

Critical Dimensions500(w) x 520(d) x 910(h) mm

Recognition Manual 2014 Page 50

Page 53: Recognition manual 2014 issue 8

600mm

Critical Dimensions600(h) x 500(w) x350(d) mm

350mm

600mm

500mm

600(h) x 500(w) x350(d) mm

Installation Detail•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.

Critical Dimensions600(h) x 500(w) x350(d) mm

Part no CN500WLH Wall Cupboard R/HPart no CN500RLH Wall Cupboard L/H

Recognition Manual 2014 Page 51

Page 54: Recognition manual 2014 issue 8

600mm600mm

Critical Dimensions500(w) x 350(d) x 600(h) mm

Installation Detail•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.

350mm500mm

Part no CN500WOS Wall Mounted Open Shelves

Recognition Manual 2014 Page 52

Page 55: Recognition manual 2014 issue 8

Cross logo suppliedby signage contractor

Critical DimensionsCritical Dimensions926(w) x 45(d) x 2040(h) mm

Installation Detail

•Sent to site without blind orhinges attached (but supplied)to enable door to be handed onsite.site.

•Door is supplied withundercoat. Top coat must beadded on site.

•Fix blind to rear of door usingappropriate fixings.

•Fix door hook to rear of door

Part no CN926WD Consultation Room Door

•Fix door hook to rear of doorcentralised at 1600mm high.

Recognition Manual 2014 Page 53

Page 56: Recognition manual 2014 issue 8

Splash Back

DCN0WPT Paper TowelDispenser 290(w) x 145(d) x265(h) mmNB Key to open dispenser isincluded and should be handed

DCN0WHS Wall MountedHand Sanitiser

156(w) x 96(d) x 265(h) mm

Critical Dimensions2000(w) x 18(d) x 550(h) mm

Installation Detail•Use appropriate fixings orgripfill to fix splash back.

Splash BackPre Laid Brushed AluminiumMDF.

included and should be handedto Pharmacy manager.

Part no CN2000SB Splash Back

gripfill to fix splash back.•Add ancillary items to positionsindicated on elevation.•Please ensure that there isenough clearance above toweldispenser to allow with openingkey.

CN00WGD Wall Mounted GloveDispenser 270(w) x 95(d) x100(h) mm

Part no CN2000SB Splash BackPart no CN00WGD Wall Mounted GlovePart no DCN0WHS Wall Mounted Hand SanitiserPart no DCN0WPT Paper Towel DispenserRecognition Manual 2014

100(h) mm

Page 54

Page 57: Recognition manual 2014 issue 8

Installation Detail

•Cut worktop to length.•Edge any exposed ends.•Fit to top of base units using appropriate fixings.•Fit to top of base units using appropriate fixings.•Cut hole for sink and mixer tap as indicated on layoutdrawing.•Cut hole for Sharps flap if required.•Fix plinth to base units using gripfill or appropriatefixings.

Part no D3000WW WorktopPart no CN00S Sink

CN2000PCBBrushed Aluminium Laminate

CN00SF Sharps Flap fittingdetail.

Part no CN00S SinkPart no CN00MT Mixer TapPart no CN00SF Sharps FlapPart no CN2000PCB Plinth to Base Unit

Brushed Aluminium Laminatefaced mdf plinth 2000(w) x18(d) x100(h) mm

Page 55Recognition Manual 2014

Page 58: Recognition manual 2014 issue 8

Installation Detail

•Position all ancillary items asper layout drawing.•Use appropriate fixings to fixheight measurer to wall.•Place child seat under bed.

Part no CN00WA Chair without ArmsPart no CN00A Chair with ArmsPart no CN00HM Height MeasurerPart no CN00WS Weighing ScalesPart no CN00CS Child Seat

Page 56Recognition Manual 2014

Page 59: Recognition manual 2014 issue 8

Critical Dimensions1000(w) x 5(d) x 800(h) mm

Installation Detail•Use appropriate fixings to fixto wall as indicated on layoutSuperdrug drawing.

Recognition Manual 2014 Page 57

Part no CN00LH Leaflet Holder with magnetic panel

Superdrug drawing.

Page 60: Recognition manual 2014 issue 8

Critical Dimensions1930(w) x 600(d) x 780(h) mm

Part no N00EC Examination CouchPart no N00CR Couch Rolls

Installation Detail

•Fix Curtain rail to ceiling asindicated on layout drawing.

Part no N00CR Couch RollsPart no N00CC Cubicle CurtainPart no N00CR Curtain Rail

Recognition Manual 2014 Page 58

Page 61: Recognition manual 2014 issue 8

N1200DK Desk to Nurses Room

Critical Dimensions1200(w) x 800(d) x 730(h) mm

N500WM Wall Mirror

N00CWA Nurse DeskChair with Arms.

Critical Dimensions470(w) x 470 (d) x 1300(h) mm

N500WM Wall Mirror500(w) x 1500(h) mm

Installation Detail•Use appropriate fixings to fit mirrorto wall 400mm from the floor.•Use mirror screw caps to coverfixings.

Part no N1200DK Desk to Nurses Room

Recognition Manual 2014 Page 59

Part no N1200DK Desk to Nurses RoomPart no N00CWA Nurse Desk Chair with ArmsPart no N500WM Wall Mirror

Page 62: Recognition manual 2014 issue 8

Addicts Area Contents

Part no. Description Page

Typical overview 61AA500AH Addicts Hatch 62AA900SD Swing Doors 63D500DP Doop Unit Small 64D550UEP - Under Worktop End panels 65D3000WW - White Worktop 66D3000WW - White Worktop 66CN00SF Sharps Flap 66

Recognition Manual 2014 Page 60

Page 63: Recognition manual 2014 issue 8

External InternalContractors must ensure that all partition walls

that make up a consultation room have adequatesound provision. Fill void with Rockwool orsimilar material. Also lay above suspended

ceiling but consult with Project Manager first tocheck that there are no asbestos issues

Typical Addicts Area OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units

Page 61Recognition Manual 2014

check that there are no asbestos issues

Page 64: Recognition manual 2014 issue 8

Installation Detail

•Cut opening in partition wall asindicated on layout drawing and addtimber studs and noggins wherenecessary to take hatch fixings.•The bottom of the opening shouldbe 1200mm above floor.be 1200mm above floor.•Insert hatch into opening and useappropriate fixings to secure.•Fit shroud to reverse usingappropriate fixings.

Note•Liaise with electrical contractor toensure cable feed for bell push is

Recognition Manual 2014 Page 62

Part no AA500AH Addicts Hatch

ensure cable feed for bell push isaccessible.

Page 65: Recognition manual 2014 issue 8

Cross logo suppliedby signage contractor

1200

1000

600

Installation Detail

•Create 1m opening in partition wallas indicated on layout drawing.•Secure stiles to frame withappropriate fixings.•Fix swing doors to stiles 600mmabove floor.

Part no AA900SD Swing Doors

Recognition Manual 2014

above floor.

Page 64

Page 66: Recognition manual 2014 issue 8

2100mm

910mm

1500mm

Installation Detail

•Cut opening in partition wall asindicated on layout drawing.•Position doop unit intoopening with the door facing 520mm

500mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

opening with the door facinginto the dispensary.•Use appropriate fixings tosecure doop unit withinpartition wall.

Recognition Manual 2014 Page 65

Part no D500DP - Doop Unit Small

Note1no adjustable shelf toeach unit.

Page 67: Recognition manual 2014 issue 8

Under Worktop End Panels

Critical Dimensions550(w) x18(d) x 920(h) mm

Installation Detail•Use top & bottom Uchannel or appropriatefixings to fix to end unit.

NoteCut and scribe piece ofwhite mfc to form frontpanel.

Recognition Manual 2014 Page 66

Part no. D550UEP - Under Worktop End panels

Page 68: Recognition manual 2014 issue 8

Installation Detail•Cut worktop to length as indicated onSuperdrug layout drawing.•Edge any exposed ends.•Fix to doop unit using appropriate fixings.

Installation Detail•Cut worktop as indicated onSuperdrug layout drawing to take flap.•Flap opens to front.

Recognition Manual 2014 Page 67

Part no D3000WW - White WorktopPart no CN00SF Sharps Flap

Page 69: Recognition manual 2014 issue 8

MDS Room Contents

Part no. Description Page

Typical overview 69Typical overview 70D500OP - Open Shelf Unit 71D600IT - IT Unit 72D400BN Bin Cupboard including pvc bin 73DCN0B Waste Bin 73DCN0B Waste Bin 73CN500LSC Lockable Storage Cupboard 74CDC500 Controlled Drugs Cabinet 75D1000GW - Grey Worktop 76D3000WW - White Worktop 76D1000ASS - Adjustable Spur MFC Shelves 77D1500EM - Ergo Mat 78D00PS - Paper Shredder 78

Recognition Manual 2014 Page 68

Page 70: Recognition manual 2014 issue 8

Recognition Manual 2014 Page 69

MDS Room OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units

Page 71: Recognition manual 2014 issue 8

Area identified fordossette boxracking

Area identified fordossette boxracking

Lockable cupboardfor confidentialwaste Phone line to

Worktop mountedprinter scanner

Recognition Manual 2014 Page 70

waste Phone line todispensary andoutside line

MDS Room Overview

Page 72: Recognition manual 2014 issue 8

910mm

Critical Dimensions

NoteIncludes 3no adjustableshelves.

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.

520mm500mm

Part no. D500OP - Open Shelf Unit

Critical Dimensions500(w) x 520(d) x 910(h) mm

Recognition Manual 2014

allows for plumbing etc.

Page 71

Page 73: Recognition manual 2014 issue 8

910mm

Critical Dimensions

NoteCut out to rear to enablecabling.

Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•Void to rear of unit and wallallows for plumbing etc.

520mm

600mm

Part no. D600IT - IT Unit

Critical Dimensions600(w) x 520(d) x 910(h) mm

Recognition Manual 2014

allows for plumbing etc.

Page 72

Page 74: Recognition manual 2014 issue 8

910mm

Critical Dimensions400(w) x 520(d) x 920(h) mm400(w) x 520(d) x 920(h) mm

Installation Detail

•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.

and to underside of worktop.•A void to rear of unit and wall

Capacity: 39 LitresDimensions: 380(w) x 280(d) x500(h) mm

520mm400mm

Part no. D400BN Bin Cupboard including pvc binPart no. DCN0B Waste Bin

Recognition Manual 2014

•A void to rear of unit and wallallows for plumbing etc.

Page 73

500(h) mm

Page 75: Recognition manual 2014 issue 8

910mm

Installation Detail

•Level using adjustable feet. 520mm500mm

Critical Dimensions500(w) x 520(d) x 910(h) mm

•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.

520mm500mm

CN500LSC Lockable Storage Cupboard

Recognition Manual 2014 Page 74

Page 76: Recognition manual 2014 issue 8

N.B. Cabinets are only to be fixed to concrete floor or structural wall with rag bolts.Where the pharmacy is on a raised floor create suitable groundings directly toactual flooring.actual flooring.

The Misuse of Drugs Act stipulates that asafe or cabinet shall be rigidly and securelyfixed to a wall or floor by means of at leastfixed to a wall or floor by means of at least

two rag bolts each passing through aninternal anchor plate of mild steel which is

at least 3mm thickness and which has asurface area of at least 19355 square

millimetres.

CDC500500(w) x 450(d) x 850(h)Floor fixed

Part no CDC500 Controlled Drugs Cabinet

Recognition Manual 2014 Page 75

Page 77: Recognition manual 2014 issue 8

The accuracy checking areais a grey worktop

Critical Dimensions3000(w) x 600(d) x30(h) mm

Accuracy Checking Area Worktop

Critical Dimensions

White worktops

Installation Detail•Cut to appropriate length as required on site.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for all corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to unitsunderneath.

3000(w) x 600(d) x30(h) mm Critical Dimensions1000(w) x 600(d) x 30(h) mm

Installation Detail•Where indicated on layout drawing fit grey worktop.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for any corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to units underneath.Seal joint to wall with white silicon.

Part no D1000GW - Grey WorktopPart no D3000WW - White Worktop

underneath.•Seal joint to wall with white silicon. •Seal joint to wall with white silicon.

Page 76Recognition Manual 2014

Page 78: Recognition manual 2014 issue 8

1234566789

1011121314151516171819202122

Installation Detail•Set Spur 150mm above the worktopto allow space for low level (90mm)electrical trunking.•Set low level trunking flush withworktop to allow a 60mm gapbetween top of trunking and the 90mm electrical

150mm fromworktop tounderside ofbetween top of trunking and the

underside of the bottom spur shelf.•Space brackets as per set out tothe right. Start at the bottom andleave three clear spaces betweenbrackets.•Make allowances for IT Monitorswhen setting out on site.•Use appropriate wall fixings.

90mm electricaltrunking

underside ofspur post

Recognition Manual 2014 Page 77

Part no D1000ASS - Adjustable Spur MFC Shelves

Page 79: Recognition manual 2014 issue 8

D1500EMErgo mat to be loose laid asindicated on layout drawing.

D00PSPaper Shredder to be placedwhere indicated on layoutdrawing.

Part no D1500EM - Ergo MatPart no D00PS - Paper Shredder

Recognition Manual 2014 Page 78

Page 80: Recognition manual 2014 issue 8

Please address any questions, comments or forPlease address any questions, comments or forinformation on the latest issue in circulation toPharmacy Development.

This is manual issue 8, for information on the latestissue release contact Pharmacy Development.Queries or comments can be directed to theQueries or comments can be directed to thePharmacy Development Manager via email [email protected]

Recognition Manual 2014 Page 79