RecommendedLightingPractices
ACollaborativeEffortbythePermianBasinPetroleumAssociation,theTexasOilandGasAssociation,theAmericanPetroleumInstitute,
UniversityLands,andtheMcDonaldObservatory*
*MuchofthelanguagehereinwasadoptedfromaBureauofLandManagementDocument,“BestManagementPracticesforReducingVisualImpactsofRenewableEnergyFacilitiesonBLM-AdministeredLands”(BLM/WY/PL-13/013+1340).
1
TABLEOFCONTENTS1.PrepareaLightingPlan 2 2.UseAudiovisualWarningSystem(AVWS)TechnologyforHazardLightingonStructuresTallerthan200feet 3 3.UseFullCutoffLuminaires 3 4.DirectLightsProperlytoEliminateLightSpillandTrespass 4 5.UseAmberinsteadofBluish-WhiteLighting 5 6.MinimizeLightingUsageduringConstructionandOperations 6 7.UseVehicle-MountedLightsorPortableLightTowersforNighttimeMaintenanceActivities 7 8.OptionsiftheNeedtoFlareArises 8Introduction: TheserecommendedlightingpracticesarearesultofcollaborationbetweenthemembersofthePermianBasinPetroleumAssociation(PBPA),headquarteredinMidland,Texas,theTexasOilandGasAssociation(TXOGA),headquarteredinAustin,theAmericanPetroleumInstitute(API),headquarteredinWashington,DC,UniversityLands,headquarteredinHouston,andTheUniversityofTexasMcDonaldObservatory,locatednearFt.Davis.ThePBPA,TXOGA,API,andUniversityLands,stronglysupporttheMcDonaldObservatoryandtheendeavorsitstrivestoaccomplish.Knowingthatdarkskiesarevitaltothoseendeavors,thePBPA,TXOGA,API,UniversityLands,andtheObservatoryoffertheincludedrecommendationstoaccomplishjustthat.TheserecommendationsaretargetedatoperationsintheTexascountiesofBrewster,Culberson,Hudspeth,JeffDavis,Pecos,Presidio,andReevestohelpprotecttheObservatory,butareequallybeneficialacrosstheindustry.FromallofusatthePBPA,TXOGA,API,UniversityLands,andtheMcDonaldObservatory,andinparticularfromthemembersoftheDarkSkiesInitiative,thankyouforfollowingtheserecommendations,andforhelpingtokeepthenightskiesofWestTexasdark.Regards,
BenShepperdPBPAPresident
BillWrenMcDonaldObservatorySpecialAssistanttotheSuperintendent
ToddStaplesTXOGAPresident
MikeSommersAPIPresidentandCEO
MarkHouserUniversityLandsCEO
2
1.PrepareaLightingPlanProjectPhase:SitingandDesign
Itisrecommendedthatalightingplanbeprepareddocumentinghowlightingwillbedesignedandinstalledtominimizenight-skyimpactsandimpactsonnocturnalwildlifeduringconstructionandoperations.Thelightingplanshouldspecifythefollowing:(1)Numberoflightsandlumenoutputofeach—Minimumnumberoflightsandthelowestluminosityconsistentwithsafeandsecureoperationofthefacility;(2)Alternativestolighting—Retro-reflectiveorluminescentmarkersinlieuofpermanentlightingwherefeasible;(3)Fixturedesign—Lightsoftheproperdesign,shieldedtoeliminateup-light,placedanddirectedtoeliminatelightspillandtrespasstooffsitelocations;(4)Lampcolortemperature—Lightsofthepropercolortominimizenight-skyimpacts;(5)Standard operating procedures—Minimization of unnecessary lighting use throughalternativestopermanentlighting,suchasrestrictinglightingusagetocertaintimeperiods;(6)Anyactivitiesthatmayberestrictedtoavoidnight-skyimpacts;and,(7)Aprocess forpromptlyaddressingandmitigating complaintsaboutpotential lightingimpactsLimitations: Safetyandsecuritymustbeconsideredindevelopingalightingplanfor
facilities and access roads. The FAA, OSHA, and other agenciesmayhaveregulationsgoverninglightingpracticesthatmustbeconsideredindesigningfacilitylighting.
3
2.UseAudiovisualWarningSystem(AVWS)TechnologyforHazardLightingonStructuresTallerthan200feet
ProjectPhase:SitingandDesignIftheFAAapprovesAVWStechnologyforgeneraluse,itshouldbeusedforstructuresexceeding200feetinheight.IftheFAAdeniesapermitforuseofthistechnology,theprojectdevelopershouldlimittheamountoflightingtotheminimumrequiredbytheFAA,inordertominimizevisibilitybeyondthatrequiredtomeetsafetyrequirements.
3.UseFullCutoffLuminairesProjectPhase:SitingandDesign
Exceptasrequiredtomeettheminimumsafetyandsecurityrequirements(e.g.,collisionmarkersrequiredbytheFAA,orotheremergencylightingtriggeredbyalarms),itisrecommendedthatallpermanentlightingusefullcutoffluminaires,whicharefullyshielded(i.e.,notemittingdirectorindirectlightaboveanimaginaryhorizontalplanepassingthroughthelowestpartofthelightsource).ItisalsorecommendedthatallpermanentlightingmeettheIlluminatingEngineeringSociety(IES)glarerequirementlimitingintensityoflightfromtheluminaireintheregionbetween80°and90°fromtheground.Itisfurtherrecommendedthatallfixturesbemountedproperly,attheproperangle.
4
4.DirectLightsProperlytoEliminateLightSpillandTrespass
ProjectPhase:SitingandDesign,Construction
Constructionandpermanentlightingshouldbemountedanddirectedtofocuslightonlyontheintendedarea,andtoavoidlightspillandoffsitelighttrespass.Lightspointingupwardorhorizontallyshouldbeavoided.Limitations: Safetyorfunctionalconsiderationsmaydictatelightingpracticesthat
resultinsomelightspillorlighttrespass.
5
5.UseAmberinsteadofBluish-WhiteLightingProjectPhase:SitingandDesign
Whenaccuratecolorrenditionisnotrequired(e.g.,roadway,basicsecurity),itisrecommendedthatlightingbeamberincolor,usingeitherlow-pressuresodiumlampsoryellowLEDlighting,oranequivalent,withLEDlightingbeingpreferredoversodium.Whenwhitelightisrequiredforaccuratecolorrendition,itshouldbelessthanorequalto3500°,andpreferablybelow3000°Kelvincolortemperature(warm-white).Bluish-whitelightingshouldnotbeusedinpermanentoutdoorlighting.Limitations: Safetyandsecuritymustbeconsideredindesigningandusing
lighting,includingthecoloringofthatlighting.Furtherofnote,lightingthatisamberorwarm-whiteincolorsometimesrequiresaspecialorderfromlightingmanufacturers.
6
6.MinimizeLightingUsageduringConstructionandOperations
ProjectPhase:Construction,Operations
Consistentwithsafetyrequirements,lightinguseshouldbeminimizedduringconstructionandoperations.Duringconstruction,localizedandportablelightingshouldbeusedwhereandwhentheworkisoccurring.Lightingshouldbepoweredbygeneratorsorelectricaldistributionwhenavailableandhaveswitchestocutpowerwhenlightingisnotrequiredduringconstruction.Lightingforfacilitiesshouldnotexceedtheminimumnumber,intensity,andcoveragerequiredforsafetyandbasicsecurity.Allarealightingshouldbedividedintoseparatelycontrolledzonestofocuslightingonsmallerareaswheretasksarebeingperformedandtoavoidilluminatingunusedspace.Arealightingshouldbecontrolledbytimers,sensors,orswitchesavailabletofacilityoperators;dusk-to-dawnlightingcontrolledbyphotocellaloneshouldnotbeallowedexceptwhererequiredforsafety.Thefacilityoperatorsshouldidentifythosecomponents/structuresthatdonotrequirecontinuouslightingforsafetyreasons.Arealightsshouldonlybeswitchedonwhenthereisaspecificneed(e.g.,personsoccupyinganarea,oralarmsituation).Whennotneeded,lightsshouldbeswitchedoff.Exceptionstoswitched-offlightingforsafetypurposesshouldbearticulatedinthelightingplan(seePBPARLP1above).Focusedtasklighting,portablelighttowers,orflashlightsshouldbeusedinsteadofarealighting,andretro-reflectiveorluminescentmarkersshouldbeusedinlieuofpermanentlightingwherefeasible.Limitations: Safetyandsecuritymustbeconsideredindesigningandusing
lighting.TheFAA,OSHA,andotheragenciesmayhaveregulationsgoverninglightingpracticesthatmustbeconsideredindesigningfacilitylightingandregulatinglightingusage.
7
7.UseVehicle-MountedLightsorPortableLightTowersforNighttimeMaintenanceActivities
ProjectPhase:Operations
Vehicle-mountedlightsorportablelighttowersarepreferredoverpermanentlymountedlightingfornighttimemaintenanceactivities.Ifpossible,suchlightingshouldbeequippedwithhoodsorlouversandbeaimedtowardthegroundtoavoidcausingglareandskyglow.Limitations: Useofvehiclelightingmustbeconsistentwithsafetyrequirements.
Somemaintenanceactivitiesmayhavelightingrequirementsthatmakevehicle-mountedlightingimpractical.
8
8.OptionsiftheNeedtoFlareArises
ProjectPhase:OperationsLimitinglightemittedbyflaringisanelementthatcouldhaveasignificantpositiveimpactonfugitivelighting,andhaveafairlyminorcommercialimpactonoperations.Thus,itisrecommendedthatlocationswithacontinuousornear-continuousflareconsiderutilizinganenclosedcombustororsimilartechnologyratherthananopenflare,wheretechnicallyandcommerciallyviable.Whilethetopofanenclosedcombustorisopen,thelightemittedfromacombustorversusanopenflareisdramaticallyless.Limitations: Safetyandsecuritymustbeconsideredindesigningandusingan
enclosedcombustor.TheEPA,RailroadCommissionofTexasandotheragenciesmayhaveregulationsgoverningpracticesthatmustbeconsideredinutilizinganenclosedcombustor.