Upload
freya
View
30
Download
0
Tags:
Embed Size (px)
DESCRIPTION
Relevant one dimensional simulations of prompt physics in thick liquid design. C/C HIB target 50, 90cm radius voids (1Torr FLiBe vapor) void fraction (0%, 50%) Initial Temperature: 600C. Presented by D. A. Haynes, Jr. for the staff of the Fusion Technology Institute - PowerPoint PPT Presentation
Citation preview
Relevant one dimensional simulations of prompt physics in thick liquid design
Presented by
D. A. Haynes, Jr.
for the staff of the
Fusion Technology Institute
University of Wisconsin•BUCKY treats superheated liquid in a manner which conserves energy at the cost of redistributing it.
•Importance of plasma shielding demonstrated by varying void radius: there is more vaporized material for a 90cm void radius than for a 50cm void radius, though the ratio is less than that of the surface areas.
•Amount of vaporized material does not depend strongly on void fraction in jet in one dimensional simulation.
•BUCKY treats superheated liquid in a manner which conserves energy at the cost of redistributing it.
•Importance of plasma shielding demonstrated by varying void radius: there is more vaporized material for a 90cm void radius than for a 50cm void radius, though the ratio is less than that of the surface areas.
•Amount of vaporized material does not depend strongly on void fraction in jet in one dimensional simulation.
•C/C HIB target
•50, 90cm radius voids (1Torr FLiBe vapor)
•void fraction (0%, 50%)
•Initial Temperature: 600C
BUCKY does treat explosive boiling, in a non-explosive sense.
• Region A– Specific Energy > Specific
Vaporization Energy– Zones join hydrodynamic mesh as
plasma with T>=T_vap• Region B
– Vaporization Energy > Specific Energy > Sensible Heat
– Energy is redistributed such that plasma facing zones are brought up to vaporization energy and vaporized, while others remain at T_vap at sensible heat.
• Region C– Sensible heat > specific energy– Hotter liquid.
Thus energy is conserved, and after each time step, there is no super-heated liquid. What is missing, however, is the effect of exploding
bubbles spewing liquid drops into the chamber.
50cm void radius results (from last time) Soon after 1 microsecond, the shock from the blowoff will interact with the shock from center of the
chamber, and we should hand off to a higher dimensional code which encompasses aerosolization and
dynamic jet location.
Vaporized mass amount due to target ions and x-rays: starting at 600C with 1Torr
vapor.
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
1.E-09 1.E-08 1.E-07 1.E-06
Time (s)
Vap
oriz
ed m
ass
(g)
Velocity profile at 1 microsecond
-6.E+06
-4.E+06
-2.E+06
0.E+00
2.E+06
4.E+06
6.E+06
0 10 20 30 40 50
Radius (cm)
Vel
oci
ty (
cm/s
)
Temperature profile at 1 microsecond
0.E+00
1.E+01
2.E+01
3.E+01
4.E+01
5.E+01
0 10 20 30 40 50
Radius (cm)
Tem
per
atu
re (
eV)
Density profile at 1 microsecond
1.E-061.E-051.E-041.E-031.E-021.E-011.E+00
0 10 20 30 40 50
Radius (cm)
Den
sity
(g
/cc)
Increasing the initial void radius to 90cm from 50cm results in more vaporization and lower plasma
temperatures.
Velocity profile at 1 microsecond
-6.E+06
-4.E+06
-2.E+06
0.E+00
2.E+06
4.E+06
6.E+06
0 20 40 60 80
Radius (cm)
Vel
oci
ty (
cm/s
)
Temperature profile at 1 microsecond
0.E+00
1.E+01
2.E+01
3.E+01
4.E+01
5.E+01
0 20 40 60 80
Radius (cm)
Tem
per
atu
re (
eV)
Density profile at 1 microsecond
1.E-061.E-051.E-041.E-031.E-021.E-011.E+00
0 20 40 60 80
Radius (cm)
Den
sity
(g
/cc)
Vaporized mass amount due to target ions and x-rays: starting at 600C with 1Torr
vapor.
0
2000
4000
6000
8000
10000
12000
1.E-09 1.E-08 1.E-07 1.E-06
Time (s)
Vap
oriz
ed m
ass
(g)
Void Radius = 50cm
Void Radius = 90cm
Increasing the void radius from 50cm to 90cm increases the amount of vaporized mass, but by
significantly less than 81/25
Vaporized mass amount due to target ions and x-rays: starting at 600C with 1Torr
vapor.
0
2000
4000
6000
8000
10000
12000
1.E-09 1.E-08 1.E-07 1.E-06
Time (s)
Vap
oriz
ed m
ass
(g)
Void Radius = 50cm
Void Radius = 90cm
•This behavior is consistent with that found for thin liquid walls.
•Practically all of the absorption of x-rays is done by vaporized wall rather than the initial contents of the “void” (18g in the 90cm case).
In BUCKY’s one dimensional approximation, varying the void fraction leads to little change in amount of material
vaporized or in the conditions of the resulting plasma
•For this case, a 90cm “void” (1Torr FLiBe vapor) radius, the C/C HIB target output, the vaporization depth differs for void fractions from 50% to 0%, but the total vaporized mass is relatively invariant.
• However, increased surface area of jets may lead to increased vaporization for 3-d geometry.
Vaporized mass as a function of time, C/C HIB target, 90cm 1Torr FLiBE, FLiBe liquid walls, T_0 =
600C
0.0E+00
2.0E+034.0E+03
6.0E+03
8.0E+031.0E+04
1.2E+04
1.E-09 1.E-08 1.E-07 1.E-06
Time (s)
Va
po
riz
ed
ma
ss
(g
)
LiquidDensity
50% voidfraction
Are these one dimensional simulations even relevant?
•Does the enormous surface area of the flapping and crossing jets assure that any aerosol, plasma, or shock-induced droplets will be swept up by the next shot?
•If not, what fraction of aerosol and plasma from the void gets out and stays in the critical driver target injection paths?
•Let’s take a moment now to discuss this.
Outstanding issue, conclusions
• Do vaporization amount, plasma charge state, aerosol amount, aerosol size matter?
• If so, increasing the void size will effect:– amount of plasma/aerosol (increase, though less
than surface area), – conditions (cooler, less dense),– importance of edge effects (increase surface to
edge).
OLD SLIDES FOR
BACKUP
BUCKY can treat “walls” in two modes, each of which has advantages and disadvantages
• “Heat capacity” EOS– Advantages:
• Latent heats easily incorporated
• Bookkeeping
– Disadvantages:• Inconsistent EOS/Opacity
as zone moves from wall to vapor.
• No shock tracking within wall.
• Only current surface zone can vaporize
• “Plasma” EOS– Advantages:
• Consistent EOS/Opacity• Shock tracking within the
wall• “Buried” “evaporation”
– Disadvantages• Currently: no latent heats
in FLiBe tables• Bookkeeping (plasma/wall
distinguished only by density)
Soon after 1 microsecond, the shock from the blowoff will interact with the shock from center of the chamber, and we should hand off to a higher
dimensional code which encompasses aerosolization and
dynamic jet location.
Vaporized mass amount due to target ions and x-rays: starting at 600C with 1Torr
vapor.
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
1.E-09 1.E-08 1.E-07 1.E-06
Time (s)
Vap
oriz
ed m
ass
(g)
Velocity profile at 1 microsecond
-6.E+06
-4.E+06
-2.E+06
0.E+00
2.E+06
4.E+06
6.E+06
0 10 20 30 40 50
Radius (cm)
Vel
oci
ty (
cm/s
)
Temperature profile at 1 microsecond
0.E+00
1.E+01
2.E+01
3.E+01
4.E+01
5.E+01
0 10 20 30 40 50
Radius (cm)
Tem
per
atu
re (
eV)
Density profile at 1 microsecond
1.E-061.E-051.E-041.E-031.E-021.E-011.E+00
0 10 20 30 40 50
Radius (cm)
Den
sity
(g
/cc)
Time (s)
Ra
diu
s(c
m)
10-9 10-8 10-7 10-6 10-5 10-4
25
50
75
100
125
150
175
FLiBeInitially in 1Torr Vapor
FLiBeInitially in Thick Liquid Walls
BUCKY "plasma" simulation
The shocks rattling around the central void render 1 dimensional simulations suspect after 20
microseconds.
•For an initial void radius of 90cm, the outward moving shock interacts with the wall blowoff around 10 microseconds.
•Note the outer wall movement at late times.
C/C HIB target, 90cm radius void, 600C, FLiBe
0.0
1.0
2.0
3.0
4.0
5.0
6.0
0 50 100 150 200
Radius (cm)
Ch
arg
e s
tate
t=1 microsecond
t=10 microseconds
As the wall blowoff moves in the chamber, it cools but remains significantly ionized as aerosolization initiates.
Initially in vapor Initially in “wall”
Does this ionization inhibit aerosol formation?
Time
Ra
diu
s(m
icro
ns)
0 50000 100000 1500000
50000
100000
150000
Log10 (T)0.50.3692160.2384330.107649
-0.0231341-0.153918-0.284701-0.415485-0.546268-0.677052-0.807835-0.938619-1.0694-1.20019-1.33097-1.46175
(ns)
A narrow band of the blowoff plasma shields the rest of the liquid from the target emissions, slowly re-radiating and
causing the rest of the wall to simmer.
BUCKY simulation of 90cm radius, 1 Torr FLiBe void, wall at 600C
•For FLiBe, with its simple atomic physics, EOS/Opacity tables can be created in DCA/NLTE with accurate emissivity values.
•For Pb, LiPb, LiSn, an alternative procedure can be employed.
Evolution of the Transition Patterns from Low Z to High Z
30 35 40
Mo (Z=42)
60 70 80 90 100
Pr (Z=59)
16 18 20 22 24 26
Kr (Z=36)
Transition: pdsd 4343 88 Cowan’s Code RSSUTA
• Under jj coupling, the initial configuration is split into:
2/16
2/52
2/3 433 sdd
2/15
2/53
2/3 433 sdd
2/14
2/54
2/3 433 sdd
• For each subconfiguration, there are two transitions:
2/12/1 44 ps
2/32/1 44 ps
• Spin orbital integrals4*)(Z
are greater than Slaterintegrals *Z
(Examples from C. Bauche-Arnoult, et al., Phys. Rev. A, 31, 2248, 1985)
Ion distributions under LTE and Non-LTE and Busquet Method
Temperature (eV)
Zbar
0 100 200 300 4005
10
15
20
25
30
35LTENonLTE
2.17)200()58( eVZeVZ LTEnonLTE
Ion Stage Population Fractions, Kr, 1e18/cc
0
0.1
0.2
0.3
0.4
0.5
0.6
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Ionization Stage
Fra
ctional Popula
tion
LTE200
LTE58
NLTE200
•What needs to be done?•Identification of variables for operating window studies•Combination of validated, relevant prompt physics simulation (rad. transport, ionization, evaporation) with validated, relevant aerosol model, and validated, relevant 3-d hydrodynamics code.•Validation of combination!•Addition of latent heat to plasma modeling of liquid wall phenomena (combine the best parts of BUCKY’s split personality)•Post-vaporization/ionization chemistry before/during/after aerosolization. •Comparison of initial vaporization phase in spherical (chamber-centric) and cylindrical (jet-centered) geometries
Path forward: prompt chamber response for thin and thick liquid wall protected IFE chambers
•Importance of results to feasibility of HIB concept•Assuming the “protection part” of the schemes work, then the key from the point of prompt chamber response is providing the correct source term for aerosolization and 3d hydrodynamic simulations.•Target conditions pre-target and pre-beam injection are crucial in determining feasibility of HIB concept.•We need a soup-to-nuts exercise of the combination mentioned previously to determine importance of prompt response to pre-next-shot conditions
•Paper study vs experimental work to get results
Path forward: prompt chamber response for thin and thick liquid wall protected IFE chambers
•Paper study versus experimental work to get results:•Wrong way to phrase the item.
•Experimental validation of models used in predictive design codes:
•Need experimental validation of evaporation, ionization, explosive evaporation.•Need aerosolization studies at extremely high temperatures with appropriate nozzles to simulate density profile (iterative).•Shock-tube work for jet array reaction to shock wave.
•RESULTS ARE VALIDATED PREDICTIVE CODES/SUITES AND THE RESULTS TEY PRODUCE.
Path forward: prompt chamber response for thin and thick liquid wall protected IFE chambers