The most cost effective and User Friendly1kHz ~ 3/13.2/26.5GHz Frequency range6.4 Inch High Resolution TFT Color LCDFast Sweep as minimum 20ms (Zero span 25)Powerful basic measurement functions such as AM/FM Demodulation, Phase Noise etc.EMC (Pre-compliance), CATV etc. various Applications Various Interfaces and Free software(USB, GPIB, RS-232C)
•••••••
www.lignex1.com
NS-30A / NS-132A / NS-265A
Reliable Mid Performance
• 1kHz ~ 3GHz• 1kHz ~ 13.2GHz• 1kHz ~ 26.5GHz
• Channel Power• Adjacent Channel Power• Occupied Bandwidth• X dB Down• Frequency Counter• Harmonic Distortion• Phase Noise Measurement• AM/FM Demodulation
• Tracking Generator• EMC Measurement S/W• Quasi-peak Detector• Distance to Fault• Return Loss Bridge Kit• CATV Measurement• Digital RBW• High Stability Oscillator• Soft Carrying Case• RF Probe• Cable & Connector Assy
• Multi-Markers(9 Markers) • Pass/Fail (Limit line)• Auto tune• Save & Load• Variable Trace Points• Easy to use
User Friendly Features
Measurement Functions
Optional Personalities
Frequency Ranges
LIG Nex1 NS Series
Spectrum Analyzer
1kHz ~ 3/13.2/26.5GHz Frequency RangeMinimum 1Hz Frequency resolutionMinimum 10Hz Resolution Bandwidth (Option)Dynamic range +30dBm to -110dBmDisplayed average noise level -115dBm (Pre-amp on -130dBm)
•••••
Harmonic distortion : ≤-75dBc, -40dBm InputIntermodulation distortion : ≤-80dBc, -40dBm InputInternal Memory up to 1,000 Data storage Auto Tune FunctionPeripheral Interface : USB 1.1 / RS-232C / GPIBPC Interface program
••••••
Excellent sensitivity, Large and Clear LCD display,Large memory, Compact size and Various options
The NS Series Spectrum Analyzer featured by high reliable synthesizer was designed to be used in diverse fields such as communications, broadcasting, RF component tests, etc. by providing excellent sensitivity.
FREQUENCY
Frequency range
AC coupled 1kHz ~ 3GHz/13.2GHz/26.5GHz
Resolution 1 Hz
Frequency reference
Temperature Drift0 ~ 50 [ppm]
±1
Aging per year* ±1
Frequency readout
Maker resolution depending on span (1Hz minimum)
Accuracy± (maker frequency*reference error + 3% span + 50% RBW )
Frequency counter
Resolution 1 Hz/10 Hz/100 Hz/1 kHz
Accuracy± (reference frequency accuracy*marker frequency accuracy + counter resolution ± 1LSB) + 0.5*last digit
Sensitivity -70 dBm @ f > 50 kHz
Frequency span
Range 0Hz, 100 Hz~3GHz/13.2GHz/26.5GHz
Resolution 1Hz
Accuracy ±3%
Sweep
Zero span 25 us to 100 sec, ±10% @ < 100 ms
Span ≥ 10Hz 20 ms to 1000 sec, ±5% @ ≥100 ms
Sweep points 501
Trigger Span ≥10Hz Source Free run, video, line, external
Spectral purity
10kHz offset [dB c/Hz] -90 dBc + 20logN
Residual FM< 100 Hzp-p in 200 ms @ RBW=VBW= 1 kHz
RBW
3dB bandwidths300 Hz to 3 MHz, 1-3-10 sequence 10, 30, 100 Hz (DRBW Option) 9kHz, 120kHz : Quasi-peak detection (option, O-QP-01)
Bandwidth accuracy± 10% (DRBW Option)± 20%
Shape factor -60dB:-3dB< 15< 5 (DRBW Option)
VBW 3dB bandwidths 1 Hz to 1 MHz, 1-3-10 sequence
AMPLITUDEDisplay range DANL to +30 dBm
Maxium input level
DC (AC coupled) ±50VDC
CW RF power +30 dBm
RF input attenuator
Range 0 to 55 dB (0 to 50dB : NS-30A)
Steps 5 dB (10dB step : NS-30A)
Switching accuracy
±0.5 dB/steps @ all frequency range±1.5 dB, all steps @ all frequency range
1 dB CP 0 dB RF attenuation [dBm]-10 @ ~ 3 GHz0 @ 3 GHz to 26.5 GHz
Third-order intermodulation distortion (TOI) [dBm]
two –30 dBm tones at input mixer with tone separation > 100 kHz+2.5 @ 1MHz to 100 MHz+5 @ 100MHz to 26.5 GHz
Second harmonic intercept (SHI)
+35 @ ~ 1.5 GHz, -30dBm input+80 @ 1.5 GHz to 26.5 GHz, -30dBm input
Displayed average noise level (DANL)
[dBm/Hz]
RBW 300 Hz, VBW 10 Hz 50Ωtermination-105 @ 50 kHz to 100 kHz-110 @ 100 kHz to 2.8 GHz-105 @ 2.8 GHz to 3 GHz-115 @ 3 GHz to 13.2 GHz (NS-132A)-110 @ 3 GHz to 13.2 GHz (NS-265A)-100 @ 13.2 GHz to 26.5 GHz (NS-265A)Pre-amp On ≤-115dBm, 50kHz to 100kHz ≤-130dBm, 100kHz to 1.8GHz ≤-129dBm, 1.8GHz to 3.0GHz
Immunity to interference
Residual responses [dBm] -85 (input termed, 0 dB attenuation)
Other spurious [dBc] -60 @ -30 dBm input
Display rangeScreen
6.4" VGA color TFT LCD 640 x 480 pixels
Log scale 1, 2 , 5, 10 dB/div
Display range
Linear scale 10 divisions
Units of level axisdBm, dBmV, dBµV, V, W (log level display) mV, µV, dBmV (linear level display)
Reference level
Logarithmic range -110 dBm to +30 dBm, 0.1 dB steps
Accuracy ±1.0dB or 1.5dB
Traces
Number 2 traces
Trace detectorsNormal, positive peak, sample, negative peak, average
Trace functionsClear/Write, Max Hold, Min Hold, Average
Frequency response
10 dB input attenuation-3dB ~ +1dB 1kHz to 5MHz± 1.0dB at 5MHz to 2.9GHz± 1.5dB at 2.9GHz to 6.4GHz± 2.2dB at6.4GHz to 13.2GHz± 3.0dB at 13.2GHz to 26.5GHz
Display nonlinearity
Logarithmic level display±1.0 dB over 10 divisions (5 or 10dB/div)±0.5 dB over 10 divisions (1 or 2dB/div)
Linear level display 3% of reference level
Bandwidth switching uncertainty
3kHz RBW reference±1.0dB
AM Demodulation
Demodulation Range5% to 90% @ 1kHz, 50% modulation, -20dBm Input
Input Level Range -2.0dBm to -70dBm @ 1kHz, 50% modulation
Frequency Response 20Hz to 30kHz @ -20dBm Input
Distortion≤5% @ 90% modulation @ 1kHz, -20dBm Input≤2% @ 50% modulation @ 1kHz, -20dBm Input
FM Demodulation
Deviation Range ≤100kHz
Input Level Range -2.0dBm to -75dBm @ 50kHz deviation
Frequency Response 20Hz to 100kHz @ -20dBm Input
Distortion≤5% @ 20kHz deviation @ 1kHz, -20dBm Input≤2% @ 50kHz deviation @ 1kHz, -20dBm Input
INPUTS AND OUTPUTS
RF inputType Front N female, 50ΩAPC 2.92 mm, 50Ω(26.5GHz)
VSWR 10 dB input attenuation <1.5
3rd IF output
Type Rear BNC female, R i = 50
Frequency 10.7 MHz
Bandwidth same as resolution bandwidth
Level +2dBm at top of screen
Specification
Spectrum AnalyzerNS Series
GENERAL SPECIFICATIONS
DisplaySize 6.4" color TFT LCD
Resolution 640 x 480 pixels, VGA
Envirironmental Conditions
Temperature ranges
Operating '0°C to +40°C
Permissible '–20°C to +60°C
Damp heatNon-condensing ( 85% operation, 90% storage )MIL-T-28800E , type 2 , CLASS 5
Mechanical resistance
Vibration, Random MIL-T-28800E , type 2 , CLASS 5
Vibration, Sinusoidal
Shock MIL-T-28800E , type 2 , CLASS 5
AltitudeOperation up to 3000 metersNon-Operating up to 40000 feet
RFI suppression (EMC)EN55011 : 1998+A1:1999 Group 1 Class AEN61326 : 1997+A1:1998
Power supply
AC supply 100VAC to 240VAC, 50/60Hz
Power consumption 100 Watts Maximum (without option)
Fuse 3.15A, 250V, Type2, 2EA
Safety EN 61010-1
Dimensions (WxHxD) [mm] 320 x 120 x 330
Weight [kg] 11.4 / 11.8
Recommended calibration interval 1 year
Warrenty 2-year
EMC analyzer option of NS-30A(O-EM-01) which is new advanced EMC measurement solution enables users to test EMI/EMC compliance. This option has
all the functions of the rediation emission measurement as well as the conductance emission measurement conforming to all the international standards. It
features the dedicated hardware and software architecture including quasi-peak detector, built-in pre-amplifier, log scales, limit lines, correction factors for
antennas, cables and amplifiers. O-EM-01 is very easy to use due to automatic measurement function, menu keys and interactive software which do not
require any special knowledge or training. So you can start EMC measurement easily and quickly.
Linear / Log Scale Measurements Peak & Quasi-Peak Measurements
Built-in Pre-amp Limit line & Correction Factors
Quasi-Peak Detector
Pre-Amplifier
EMC MeasurementSoftware
Spectrum AnalyzerNS Series
EMC Application
Reference frequency input
Type Rear Same as reference ouput port
Frequency 10 MHz
Required level –5 to +15 dBm nominal
GPIBType Rear
IEEE 488.2 24-pin female
Interface functionsSH1, AH1, T5, L3, SR1, RL1, PP1, DC1, DT1, C0, PP0, SR0, DC0, DT0, C1, C2, C3
Serial interface Rear RS-232-C (COM), 9-pin D-SUB female
USB Front 1.1 or Higher(2.0)
Printer interface Rear parallel (Centronics-compatible)
Monitor output (VGA) Rear 15-pin mini D-SUB, 640 X 480
Mouse connector Rear PS/2-compatible, for factory-use only
Keyboard connector FrontPS/2 female for MF2 keyboardfor factory-use only
Probe power supply
Front +15V,-12V, GND
Audio output Type Front phone jack
Ext trigger input
Type Rear BNC female, 10 kΩ nominal
Trigger level 5 V TTL nominal
Sweep gate output
Type Rear BNC female
Trigger level 0 ~ 5 VDC
Video outputType Rear BNC female
Voltage 0 ~ 5VDC
Reference frequency output
Type Rear BNC female
Frequency 10 MHz
Level +5 dBm
Total Measurement
Multi-Carrier Measurement
C / N Ratio
CSO / CTB
Depth of Modulation
HUM
Carrier Lavel, Frequency
Cross Modulation
Total Measurement Multi-Carrier C/N Ratio CSO / CTB
Cable TV analyzer option(O-CT-01) of NS-30A provides the most economical test solution for cable TV signal measurements. In addition, it is very portable and easy to use. CATV Option features the dedicated hardware and software architecture which consist of the built-in preamplifier, 75 ohm input impedance match, TV trigger, precise frequency reference and many other functions. It enables users to measure the cable TV carrier signal level, frequency, C/N(Carrier-to-noise), CSO/CTB, HUM and many other characteristics of cable TV signal which are compatible with world wide formats and standards. Especially, Total Measurement and Multi-carrier measurement functions are very convenient and remarkable features for the fast and efficient measurement control.
Depth of Modulation HUM Carrier Level, Frequency Cross Modulation
CATV Application
VSWR (Return Loss)Check the return loss of the feeder between the transmitter and antenna.
Necessary accessoriesReturn Loss Bridge, RF Cable, Adapter, Tracking Generator
DTF (Distance to Fault)When VSWR of the cable deviates form the normal measurement result which was given to each cables, user can pinpoint the fault in the cable by operting the DTF mode.
Necessary accessoriesPower Divider, RF Cable, Calibration Road, Tracking Generator
Cable Fault Finding Measurements
Cable Information Data
Trace & State Save / Recall
DTF MeasurementSoftware(Option)
Spectrum AnalyzerNS Series
Fault
Power Divider or Return Loss Bridge(Option)
Tracking Generator(Option)
Distance to Fault(DTF) option (O-DF-01) which is the advanced cable test solution allows to detect the faults in the cable at mobile station, transmitter site or other system. Using the return loss bridge, DTF option enables the user easily and quickly locate the faults in the cable because the database of DTF option on NS-30A has the characteristics of hundreds of cables.
DTF (Distance to Fault) Application
Floor 11/12, Prudential Tower, 838 Yeoksam-dong, Gangnam-gu, Seoul, Korea Tel: 82-2-2033-0495/8 Fax: 82-2-2033-0602
Option ListOption No. Description Availability
Tracking Generator O-TG-02 9kHz ~ 3 GHz, 0 ~ -70dBm Only NS-30A
High Stability Oscillator O-HS-01 10MHz, 0.2ppm ALL Models
EMC Analyzer O-EM-01 Up to 3GHz / Radiated, Conducted Emission ALL Models
Quasi Peak Detector O-QP-01Band B : 150kHz ~ 30MHz (RBW: 9kHz)
ALL ModelsBand C/D : 30MHz ~ 1GHz (RBW: 120kHz)
Digital RBW O-DR-01 RBW : 10Hz, 30Hz, 100Hz ALL Models
Distance to Fault(DTF) O-DF-01 Cable Fault Locator Only NS-30A
Return Loss Bridge Kit O-RB-01 Return Loss Bridge, Cable Set Only NS-30A
CATV Analyzer O-CT-01 NTSC, PAL ALL Models
Soft Carrying Bag O-SB-01 Carrying Bag ALL Models
Standard Functions
Channel Power Adjacent Channel Power (ACP) Occupied Bandwidth
XdB Down Harmonic Distortion(Total Harmonic Distortion) Marker(Multi-Peak/Marker Table)
AM/FM Demodulation Frequency Counter Trace