12
www.prana.org.ua Remote control manual

Remote control manual · “Selected operation mode” flashes each second on the indica-tion panel. For extra comfort of the organizations of ventilation of living quar-ters, the

Embed Size (px)

Citation preview

www.prana.org.ua

Remote control manual

11:59

On/Off “Mini-warm-up”

Operating modes switching

“Night” mode

On/Off

“Winter” mode

Sleep timer

“Fan” mode

Adjustment of brightness indication

2

Adjustment of brightness indication

Turn “Mini-heating” Off Turn “Mini-heating” On

Operating modesswitching

“Night” mode

Turn Off

zz z

“Winter” mode

Sleep timer

“Fan” mode

3

1.First start

11:59

Check if power is connected to the vent system. NO INDICATION – electric current doesn`t flow. “-“ electric current flows, but system is off.

Start the mobile application. Bluetooth service will turn On auto-matically and application will be connected to the vent system. Sys-tem is ready for use.

2.Adjustment of brightness indicationTo provide customer with the most comfortable usage experi-

ence during the dark, our system has 6 indication brightness levels.Indication brightness can be adjusted by * button on the re-

mote controller or * button in the mobile application.

4

11:59

“L” (LOW) displays on indication panel – “Night” mode is On. Min-imal vent system operating mode.

For “Winter” mode tap * button in the application or press on your remote controller.

Volume of air exchange at “Night” mode м3/hour:

150 | 200G | 200C | Model 25 | 25 | 40 | Supply 22 | 22 | 36 | Exhaust

Recuperation efficiency %: 91 | 92 | 93

Noise level at 3m. distance dB: 5 | 4 | 4

3.“Night” more

5

11:59

/105

Numbers from 2 to 9 on the indication panel – system works in appropriate operating mode.

Setting up system air exchange performance from 20% to 90%. Each mode increases/degreases performance by 8%. Can be man-aged by buttons +/- via application or +/- on remote controller.

* - Parameters that are shown in the graphs could vary by +-4% from real parameters depending on weather conditions, atmospheric pressure, relative humidity of air, etc…

4.Operating modes 2-9

6

260

240

220

200

180

160

140

120

100

80

60

40

20

0L 2 3 4 5 6 7 8 9 H

40

35

30

25

20

15

10

5

0L 2 3 4 5 6 7 8 9 H

100

90

80

70

60

50L 2 3 4 5 6 7 8 9 H

Volume of air exchange м3/hour

Noise level, dB

Recuperation efficiency %

Prana-150

Prana-200G

Prana-200C

Prana-150

Prana-200G

Prana-200C

Prana-150

Prana-200G

Prana-200C

76

11:59

/1010“H” (HIGH) on the indication panel – system works in “Fan” mode.

Maximal vent system operating mode.

For “Fan” mode tap * button in the application or press on your remote controller.

Volume of air exchange in “Fan” mode м3/hour:

150 | 200G | 200C | Model 115 | 135 | 235 | Supply 105 | 125 | 220 | Exhaust

Recuperation efficiency %: 67 | 70 | 62

Noise level at 3m. distance dB: 30 | 29 | 34

5.“Fan” Mode

8

6.“Sleep timer” function

11:59

/101

00:10:00

“Selected operation mode“ on the indication panel, «S» flashes each 5 seconds.

“Sleep timer” function turns on by tapping button in the application or pressing button on the remote controller.

To manage timer duration use +/- buttons in application or +/- on the remote controller. After the timer expires, system will turn off au-tomatically. There are 9 default timer configurations. When choosing one of the configuration, numbers from 1 to 9 will appear on indica-tion panel.

Timer configurations:1 – 10 minutes2 – 20 minutes3 – 30 minutes4 – 1 hour5 – 1 hour 30 minutes6 – 2 hours7 – 3 hours8 – 5 hours9 – 9 hours

5SEC

8 9

zz z

“Selected operation mode” flashes each second on the indica-tion panel.

For extra comfort of the organizations of ventilation of living quar-ters, the Prana household and semi-industrial systems are equipped with a “Mini-warm-up” function of the supply air. Function turns On by tapping button in the application or pressing button on the remote controller.

When “mini-warm-up” is On, temperature of the supply air addi-tionally warms up by 3 – 5°C.

ATTENTION! In the case of air temperature outside lower than 0°C in the rooms with the humidity of 55% or higher to avoid icing of the condensate discharge paths vent system “Mini-warm-up” function must be turned On.

7.“Mini-warm-up” function

11:59

/1010

1SEC 1SEC

10

11:59

/103

00:00:58

Near the selected operating mode on the indication panel each second flashes “.” – “Winter” function is On, heating element works.

“.” displays on the indication panel near the selected operating mode – “Winter” mode is on, heating element works in passive mode and turns on automatically when needed.

“Winter” function intended to prevent icing of the condensate discharge paths in the cold season or to defrost paths in the case of already formed icing.

ATTENTION! To prevent icing and ensure correct work of the sys-tem in the case of sub-zero temperature outside the room – system must work with “Winter” mode turned On.

Turn “Winter” function on by tapping * button in application or pressing * button on your remote controller and choose needed operating mode of the vent system.

After “Winter” function timer expired system will start working in selected operating mode.

ATTENTION! Vent system engines will start only after “Winter” func-tion timer expired.

8.“Winter” function

1SEC 1SEC

11

tel./fax: +38 032 232 53 39 e-mail: [email protected]

Ukraine, 79021, Lviv,Kulparkivska st. 93А

www.prana.org.ua

10/05/18