Report from Florence
Bonding of Modules L12p
Mirko Brianzi
20 April 2004
CERN, 20 Apr 2004 Mirko Brianzi 2
Bonding Setup in Florence
Dage 3000Delvotec 6400
There is a new Pull Tester in our system,now we are finally able to make good pull test.
CERN, 20 Apr 2004 Mirko Brianzi 3
Status• Since March bonded 22 new modules (6 chips).• For this L12p modules the loop height is very important, so it took a lot of time to set all the loop parameters and solve some problem.
• Now a new program for Delvotec is ready and it automatically bonds all the front side of the module, making all the loop shapes more reproducible (as much as possible).
• The failure rate for these modules has been 3fail/module because they are the first ones and we had to fix some problem, actually the last ones hadn’t any fail.
CERN, 20 Apr 2004 Mirko Brianzi 4
PA movingThe main reason of failure is the PA not glued at the edge and this make often fail someone of the last bonds.
Insert of teflon
Making some pull test on bad bonds we can say that anyway too weak bonds are well visible.
Solution:
CERN, 20 Apr 2004 Mirko Brianzi 5
Gold pad movingSimilar problem bonding Bias to Filter Pad because the bond position is outside the Jig.
support
silicon
end of jig
bonds
carrier
Lateral View:
CERN, 20 Apr 2004 Mirko Brianzi 6
Dirt
Sometimes bonding pads on PA are dirty and this has caused some fail.
CERN, 20 Apr 2004 Mirko Brianzi 7
PA gap
For example…
PA-Si gap can vary between 100µm and 220µm.
302 000 200 35 277
302 000 200 35 278
Very difficult to reproduce exactly the same loop height because the mechanical assembly of the module influence the bond loop.
100
220
CERN, 20 Apr 2004 Mirko Brianzi 8
VacuumBecause the mechanical difference between each module, sometimes the vacuum flex the silicon during bonding…
…so the central bonds can result 50µm higher (or more).
CERN, 20 Apr 2004 Mirko Brianzi 9
Readout bonds
Loop heights are as much as possible (within the specifications).
240340
Specifications:min. 200µm max. 350µm?
CERN, 20 Apr 2004 Mirko Brianzi 10
Bias bonds
Bonds in this module are too high but they have been corrected to 250µm.
370
Specifications:min. 200µm max. 350µm?
CERN, 20 Apr 2004 Mirko Brianzi 11
Filter bondsIt’s very difficult to stay inside the specifications. 420525
Specifications:min. 500µm max. 600µm
In case that some bond is too low, we could accept it if it’s above a “safe limit” (350µm?).
3kV/mm (dry air)500V=>170µm
CERN, 20 Apr 2004 Mirko Brianzi 12
Pull Test on PA
Results of Pull Test on test bonds on PA
for 8 modules:
Mean force = 9.6g
Standard deviations = 0.22 - 0.37g
Abs. minimum value = 8.4g
CERN, 20 Apr 2004 Mirko Brianzi 13
Pull Test on Readout bonds
Results of Pull Test on Readout bonds
for 5 modules
Mean force = 11.1g
Standard deviations = 0.69 – 0.99g
Abs. minimum value = 9.0g( Correction Factor = 1.4 )
CERN, 20 Apr 2004 Mirko Brianzi 14
Pull test correction
Measured geometry of bonds used for pull test to define the correction factor.
Factors:16°=1.8118°=1.6220°=1.4625°=1.1827°=1.1030°=1.00
Angles can vary depending on theexact point where the wire is pulled:25°-27° for PA test bonds => factor = 116°-20° for readout bonds => factor = 1.4
These factors seems very high…
CERN, 20 Apr 2004 Mirko Brianzi 15
Pinholes after bonding
Found after bonding2 pinholes not presentin the Database.1 of them is probably caused by a fail during bonding.
The correspondent bond have been removed…
…in this case do we have to update the Bonding Database?
CERN, 20 Apr 2004 Mirko Brianzi 16
Conclusion
• New bonding program for Delvotec include also the automatic pattern recognition and it is fast and efficient (using some “trick” to avoid failure on PA).
• No problems with Data Base, it has been updated to the last version.
• Good and uniform pull test results.