Reqd Data - Bridge Load Tests

Embed Size (px)

Citation preview

  • 7/28/2019 Reqd Data - Bridge Load Tests

    1/1

    9948 - Deign Department

    STANDARD LIST OF DATA REQUIRED FOR DESIGNS

    Unit to be Designed :- Load Test on the Bridge Girder

    Required data :-

    1) Pier Numbers between which span is to be tested : (exact location)Relevant Drawing Numbers (for super / sub structure) :

    Relevant Design document (for super / sub structure) :

    Name of the Designer (Consultant) :

    Name of the Proof checking Agency :

    2) Details of Bridge Super Structure : Span of Girder m (C/C of bearings)

    Distance between piers m (C/C span 'L' )

    Number of Lanes m

    Width of Deck m

    Depth of Girder m

    Camber / Gradient (if any)

    Cross section Type (Box, 'I', Voided, Slab)

    Type of Loads (Rail / Road)

    Steel / RCC / PSC

    Age of Girder to be tested (New / Old)

    3) Load-Test Set up :- Governing Load case Nos.

    Loading by Static Platform - or - Trucks

    Make and Dimensions of Truck planned (including Axel Loads) (Empty & Full)

    Method Statement of Loading / Unloading

    Method of Calibration / Agency to estimate deflection

    4) Safe Bearing Capacity of the Soil - : T/sqm

    Depth at which SBC is available below Ground level m

    Depth of Ground water Table below FGL. m

    5) Site Conditions - Type of Service below the Deck (Rail / Road / Water etc.)

    Depth of Water, velocity etc. (if any) m

    Clear Height available below soffit m (to estimate staging)

    6) Material Availability : New

    Old / available (Give Details)

    7) Any relevant Information available :

    8) Design / Details Required by what date :

    L

    Depth of Water

    (If Any)

    W

    D

    H

    Typical Elevation Schematic Section

    Provide more details if

    available;

    or any contractual

    specifications related to

    load-test etc.