Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
REQUEST FOR PROPOSALS
FOR A WATER-FOCUSED CUSTOMER PORTAL IN SUPPORT OF THE
ADVANCED METERING INFRASTRUCTURE (AMI) PROJECT
JOB 10062
PROPOSALS DUE:
October 31, 2019 2:00 p.m.
ALAMEDA COUNTY WATER DISTRICT 43885 South Grimmer Blvd, Fremont, California 94538-6348
(510) 668-4499 Engineering Office www.acwd.org
OCTOBER 2019 ALAMEDA COUNTY WATER DISTRICT
REQUEST FOR PROPOSALS
ACWD JOB 10062 Water Focused Customer Portal RFP 2
Table of Contents 1.0 INVITATION TO SUBMIT PROPOSALS ..................................................................................................... 4
1.1 Introduction ....................................................................................................................................... 4
1.2 Pre-Proposal Conference ................................................................................................................... 4
1.3 RFP Closing ......................................................................................................................................... 4
1.4 Confidentiality and Waiver of Claims ................................................................................................. 5
1.5 Confidential Indemnity ...................................................................................................................... 5
1.6 Contract Documents .......................................................................................................................... 6
2.0 BACKGROUND ........................................................................................................................................ 7
3.0 PURPOSE ................................................................................................................................................ 9
4.0 CUSTOMER PORTAL GOALS ................................................................................................................... 9
5.0 PROPOSER’S EXPERIENCE AND QUALIFICATION REQUIREMENTS ....................................................... 10
6.0 SCOPE OF WORK & SUBMISSION REQUIREMENTS .............................................................................. 11
6.1 General Software Requirements ..................................................................................................... 11
6.2 Application Overview ....................................................................................................................... 14
6.3 Customer Facing Functionality ......................................................................................................... 16
6.4 Utility Facing Functionality ............................................................................................................... 19
6.5 Implementation and Training .......................................................................................................... 20
7.0 ADDITIONAL REQUIREMENTS .............................................................................................................. 26
7.1 California Consumer Privacy Act ...................................................................................................... 26
7.2 Information Protection and Personal Privacy .................................................................................. 26
8.0 COMPENSATION .................................................................................................................................. 26
9.0 PROPOSAL ELEMENTS .......................................................................................................................... 29
9.1 Instructions ...................................................................................................................................... 29
9.2 Proposal Structure ........................................................................................................................... 30
10.0 CLARIFICATION OF PROPOSALS / WITHDRAWAL OF REQUEST FOR PROPOSALS .. Error! Bookmark not defined.
11.0 SUBMISSION OF PROPOSALS ............................................................................................................... 35
12.0 EVALUATION OF PROPOSALS ............................................................................................................... 35
12.1 Instructions ...................................................................................................................................... 36
12.2 Evaluation Process ........................................................................................................................... 36
12.3 Evaluation Criteria ............................................................................................................................ 37
12.4 On-site Demonstration and Interview ............................................................................................. 39
12.5 Financial Evaluation ......................................................................................................................... 39
12.6 Total Evaluation ............................................................................................................................... 39
12.7 Statement of Work........................................................................................................................... 39
ACWD JOB 10062 Water Focused Customer Portal RFP 3
13.0 PROPOSER SELECTION SCHEDULE (Subject to Change) ....................................................................... 40
14.0 CONFIDENTIALITY................................................................................................................................. 40
15.0 JOINT PROPOSALS ................................................................................................................................ 40
16.0 INSURANCE ......................................................................................................................................... 41
17.0 DATA AVAILABLE FROM ACWD ............................................................................................................ 43
List of Appendices
• Appendix A – Technical Proposal Submittal Form • Appendix B – Cost Proposal Submittal Form • Appendix C – Sample Agreement / Software-as-a-Service (SaaS) Requirements • Appendix D – AMI Business Drivers • Appendix E – Current Invoice Cloud and CSS System Architecture Diagram • Appendix F – Diagram of the Anticipated Interfaces with the Selected AMI System
ACWD JOB 10062 Water Focused Customer Portal RFP 4
ALAMEDA COUNTY WATER DISTRICT REQUEST FOR PROPOSALS
WATER-FOCUSED CUSTOMER PORTAL
1.0 INVITATION TO SUBMIT PROPOSALS
1.1 Introduction
The Alameda County Water District (District or ACWD) supplies water to a population of over 357,000 in the cities of Fremont, Newark, and Union City. The District was established in 1914 by the state legislature under the California County Water District Act and is governed by a five-member Board of Directors. It was originally created to protect the groundwater basin, conserve the waters of the Alameda Creek Watershed, and develop supplemental water supplies, primarily for agricultural use. In 1930, urban water distribution became an added function of the District. Today, the District provides water primarily to urban customers.
The District is seeking proposals from qualified respondents for a water-focused customer portal in support of a District wide Advanced Metering Infrastructure (AMI) project.
At a minimum, ACWD is looking for a customer-facing web-based application with customer alert and notification functionality, and Utility-facing web-based dashboard and reporting feature sets as outlined in this Request for Proposal.
1.2 Pre-Proposal Conference
There will be a non-mandatory pre-proposal conference at the District Office, 43885 South Grimmer Boulevard, Fremont, California, on October 16, 2019 at 10:00 a.m. PST that can be attended in person or remotely.
Please contact Christine Santiago at phone: (510) 668-4408 or email: [email protected] to register for remote access to the pre-proposal conference. Remote access will be provided via the District’s WebEx account. The District makes no assurances with regard to the quality or uptime of the WebEx remote access interface, nor will the District provide any troubleshooting services. Proposers should plan their attendance to the Pre-proposal Conference accordingly.
During the pre-proposal conference, Proposers may ask questions about the RFP. Formal questions regarding the RFP will be submitted and answered in accordance with Section 10 “Clarifications of Proposals / Withdrawal of Request for Proposal”.
1.3 RFP Closing
Sealed proposals to provide the Water Focused Customer Portal will be received by the District Secretary of the Alameda County Water District at its offices, 43885 South Grimmer Boulevard, Fremont, California 94538, until closing time of 2 p.m., Pacific Standard Time (PST), on October 31, 2019.
ACWD JOB 10062 Water Focused Customer Portal RFP 5
1.4 Confidentiality and Waiver of Claims
The California Public Records Act (Cal. Govt. Code Sections 6250 et seq.) (CPRA) mandates public access to government records. Therefore, unless the information is exempt from disclosure by law, the content of the proposal, as well as any other written communication between District and the Proposer, is a public record that must be made available to the public.
If the Proposer believes any communication contains information exempt from disclosure under the CPRA, including trade secrets or other proprietary information that the Proposer believes would cause substantial injury to the Proposer’s competitive position if disclosed, the Proposer must request that the District withhold from disclosure the exempt information by submitting:
1. An unredacted copy of the proposal marking each page containing such exempt information as confidential; and
2. A redacted copy of the proposal that redacts the purportedly exempt information; and
3. A separate "confidentiality index" including all of the following information:
a. The section and page number of the proposal where the information is located; and
b. An explanation of why the information is exempt from disclosure under the CPRA.
4. By submitting a proposal, Proposer:
a. Consents to the release of the redacted version of the proposal; and
b. Consents to the release of any portion of its proposal not included in the confidentiality index; and
c. Waives all and agrees not to bring any claims against the District, its directors, officers, employees and agents, for the disclosure of such information.
If the Proposer does not include a confidentiality index in its proposal, the District will have no obligation to withhold any information from disclosure and may release the information sought without liability to the District.
In the event of conflicts between the redacted version, the confidentiality index, and confidentiality designations in the body of the proposal, the redacted version prevails.
A Proposer may not designate its entire proposal as confidential. The District will not honor such designations and will disclose submittals so designated to the public without liability to the District.
1.5 Confidential Indemnity
Upon receipt of a request pursuant to the CPRA seeking proposal material relating to this RFP, the District may provide the redacted version of the proposal or may withhold material designated in the confidentiality index that is exempt from disclosure. If the District determines that information in the confidentiality index is not exempt from disclosure, the District will give reasonable notice to the Proposer prior to releasing any material listed in the confidentiality index.
By submitting a proposal, Proposer agrees to indemnify, defend, and hold harmless the District, its directors, officers, employees and agents, from any and against all damages (including but not limited
ACWD JOB 10062 Water Focused Customer Portal RFP 6
to attorneys’ fees that may be awarded to the party requesting the proposer information), and pay any and all cost and expenses, including attorneys' fees, related to the withholding of the information included in the confidentiality index or in the redacted version of the proposal. If Proposer fails to accept a tender of a defense, the District reserves the right to resolve all claims at its sole discretion, without limiting any rights stated herein.
1.6 Contract Documents
The Contract Documents are made up of the following parts: • Addendum • Statement of Work • SaaS Agreement • Proposers response to Part 8 • RFP Specifications
RFP documents for this work are available for inspection during normal business hours at the office of the District. The RFP documents may be downloaded from the District’s website (www.acwd.org) under “Current Consultant & Services Opportunities”.
There is no charge for the first hard copy but there is a nonrefundable charge of $30 for each additional copy of the RFP Documents obtained at the office of the District.
There is an additional nonrefundable delivery charge of $20 for each copy of the RFP Documents delivered by surface transportation or mail.
Ed Stevenson Manager of Engineering & Technology Services Alameda County Water District
ACWD JOB 10062 Water Focused Customer Portal RFP 7
2.0 BACKGROUND
The Alameda County Water District (District or ACWD) is pursuing the deployment of an Advanced Metering Infrastructure (AMI) system, which is scheduled for completion by approximately December 2022.
The District’s existing metering infrastructure is comprised completely of conventional meters that are read manually, and billed every 60 days. This legacy metering model has served the District well for the past 85 years. The District is looking to replace this system with a solution of 20+ year lifecycle to meet the District’s future metering needs. Additionally, the District recognizes that a successful conversion to AMI will require modification of not just existing infrastructure but also existing business processes.
In support of the Advanced Metering Infrastructure (AMI) Project, the District is currently undertaking two procurements, which have been released in parallel:
RFP-1: Request for Proposals for “Turnkey” Deployment Solutions in Support of the Advanced Metering Infrastructure (AMI) Deployment Project (outside of scope for this procurement); and
RFP-2 (this document): Request for Proposals for a Water-Focused Customer Portal in Support of the Advanced Metering Infrastructure (AMI) Project (this RFP procurement document).
The RFP-1 will procure a “turn-key” District wide Advanced Metering Infrastructure (AMI) system including provision of an AMI data collection network with District-wide coverage, the upgrade of water meters to be AMI compatible, water meter and water meter register supply and installation, the supply and installation of AMI radio transmitters for all District accounts, and provision of a fully-functional AMI meter data collection software and meter data management software. The AMI system will cover the entire District service area and all approximately 85,000 service connections.
RFP-1 is anticipated to be awarded in February 2020. The District’s evaluation and selection of the responses to RFP-1, i.e. the AMI Deployment solution including the AMI system and supporting software platforms, is ongoing. The Water-Focused Customer Portal will be required to seamlessly interface with the selected AMI solution.
In addition to the new software platforms procured under RFP-1, the District has a suite of existing enterprise software platforms. The platforms that the Water-Focused Customer Portal may need to seamlessly interface with include the following:
• Invoice Cloud Electronic Bill Presentment & Payment (EBPP) system.
• Selected AMI system and MDM procured with RFP-1.
• Cayenta Customer Information System (CIS).
• Cayenta Self Service portal (will be replaced by the Customer Portal)
The District has implemented Cayenta Customer Self Service (CSS) which is currently the District’s water customer web landing page. The Customer Portal will replace the CSS.
The CSS provides water customers with the following functionality:
• Initial Customer sign up.
ACWD JOB 10062 Water Focused Customer Portal RFP 8
• Customer information updates.
• Self-service password changes.
• Account details.
• Transaction history.
• Consumption analysis.
• Utility requests (Start service, stop service, request history, or contact from the District).
The Invoice Cloud SaaS application, which the Customer Portal will integrate with, provides water customers with the following functionality:
• Function performed that require login:
o Customer sign in authentication process
o Bill presentment.
o Setup and processing Autopay payments (automatic payments).
o Setup and status of paperless billing (eBilling).
• Functions performed that do not require login:
One-time payment process (QuickPay).The current Invoice Cloud and CSS system architecture diagram is provided in Appendix E. Appendix F includes a diagram of the anticipated interfaces with the selected AMI system. The Proposer may adjust the interfaces architecture based on the selected AMI vendor.
The District has planned for the AMI project to be implemented in a number of phases. The initial priority will be to successfully implement the AMI system prior to beginning the Water-focused Customer portal. Within the AMI RFP the phases are described as follows:
• Startup Phase: The goal of this phase shall be for the District and the AMI Contractor to plan, prepare, setup, test, mobilize and document all components to be implemented under this phase. The AMI Contractor shall provide installation services and plan, communicate, and place into operation the systems and processes to support the implementation of the AMI System.
• Proof of Concept Phase: The goal of this phase is to prove that the Contractor’s systems and installation processes can be successfully implemented with the District’s systems to prove the District’s systems and business processes are able to support the AMI system prior to the District issuing a second Notice to Proceed, which will allow the AMI Contractor to proceed to the Production Phase. This phase will include the installation of approximately 3,000 water meters and is expected to be complete around December 2020.
• Production Phase: In this phase the AMI Contractor shall install all of the meters, meter components, radio transmitters, and data collection equipment not already installed during the Proof-of-Concept Phase.
ACWD JOB 10062 Water Focused Customer Portal RFP 9
It is anticipated the Water-focused Customer Portal agreement will be awarded concurrently with the AMI Deployment contract at the February 2020 Board Meeting, with an anticipated go-live shortly after completion of the Proof of Concept infrastructure deployment.
3.0 PURPOSE The purpose of this RFP is to select a Water-focused Customer Portal that will replace Cayenta’s CSS as the District main water customer web landing page, suppress the Invoice Cloud application (through API’s) and enhance customer service by using the selected AMI system’s hourly consumption data (see Section 4 for customer portal goals). The District wants to eliminate obvious differences between the District’s web page and Customer Portal pages.
The District does not want to reduce the features and functionality currently available to water customers; at a minimum, the preferred solution should continue to provide CSS and Invoice Cloud’s functionality.
4.0 CUSTOMER PORTAL GOALS The District completed a needs assessment and a comprehensive business case to help guide the scope of the Advanced Metering Infrastructure (AMI) Deployment Project. As a part of this process, the District identified a number of goals and AMI business drivers that the District wanted to achieve and deemed as essential to the overall solution. Included in Appendix D “AMI Business Drivers” is a table with a detailed description of all the AMI business drivers the District determined were important to achieve with an AMI solution.
These business drivers are the fundamental drivers for the AMI Project and identify key functional success criteria for the AMI Project. To maximize the value of the solution, the District expects that the selected Customer Portal will excel in providing the features and functionality defined in the Business Drivers. The AMI Business Drivers that most directly relate to the Customer Portal have been summarized below.
Business Drivers Description in relation to the Customer Portal
Revenue Continuity • Tamper detection
Customer Engagement
• Generate goodwill with the District’s customer base • Reactive use of leak detection • Proactive use of leak detection • Customer consumption analysis • Vacation monitoring • Reduce billing exceptions • Reduce billing error complaints • Enhance conservation and engagement
District Absorption • Same day finals and special reads • Achieve cost savings by reducing truck rolls
Operational Enhancements • Bylaw enforcement
ACWD JOB 10062 Water Focused Customer Portal RFP 10
Additionally, the customer portal is expected to provide a platform that will facilitate and support the following business functions:
• Water conservation initiatives via usage analysis and targeted outreach to customers with high or atypical use.
• Leak identification and customer alert service tools.
• Initiate proactive customer service and notifications/alerts.
• Customer self-serve access to usage data and service functions with a seamless customer experience with Invoice Cloud.
• Better manage customer complaints and improve customer satisfaction.
• Aid in the transition from monthly to hourly (AMI) data.
In support these goals, the primary objective of the Proposer will be to provide:
• A customer-facing web-based application and native application for common smart phone and tablet devices.
• A utility-facing web-based application with analytics dashboard.
• The ability to send a range of automatic and customizable digital alerts and notifications.
• Promote the adoption rate and bi-monthly utilization of District Customers to the Customer Portal platform.
• Support the District’s absorption of the AMI system, via support for the transition of associated business processes and training for District staff.
Time is of the essence. The Proposer shall ensure the availability of resources, as necessary, to facilitate work in a timely fashion and as detailed in the RFP documents.
5.0 PROPOSER’S EXPERIENCE AND QUALIFICATION REQUIREMENTS The Proposer shall be competent in executing the various elements described in this RFP and indicate in their proposal their suitability and experience executing similar projects. No change or substitution of named subcontractors, vendors or products will be allowed.
It is highly desirable that the Proposer have a minimum of 5 years of industry experience. Proposer is requested to provide at least three references for water utility customers where similar programs have been implemented using the proposed solution. References must include Utility, program manager name, title, and contact information as well as the specific project dates, number of water meters under management, short description of program, time to launch (contract signing to start of program) and results.
Proposer’s key project team staff shall be competent at executing the various elements of work described in this RFP. Key project staff shall be identified in the proposal, indicating their suitability for this project and experience executing similar projects. The proposed Project Manager shall be
ACWD JOB 10062 Water Focused Customer Portal RFP 11
identified and have direct experience leading projects of this nature. Resumes for key staff should be included in an appendix to the proposal (including name, role, location, tenure and experience with similar projects).
No change or substitution of named key project staff will be allowed unless written approval, which may require submission of experience and qualification evidence to the satisfaction of the District, is obtained from the District.
The District expressly reserves the right to reject any Proposal if it determines that the Proposer’s business and technical organization; financial resources; key project staff; and/or lack of successful experience in performing work of similar type and magnitude is such that it is not in the District’s best interest to accept the Proposer’s Proposal.
6.0 SCOPE OF WORK & SUBMISSION REQUIREMENTS
6.1 General Software Requirements
6.1.1 Software Overview
All references to “software” or “application” will refer to the Proposer provided, Software-as-a-Service (SaaS) application(s) required to operate the water-focused customer portal application and meet the specifications as detailed. Where a software application can be provided both as an on-premise or in a SaaS environment, the Proposer shall price the SaaS as the base solution (preferred) and provide the on-premise as an alternative. See Appendix C - SaaS Requirements Form for the District’s SaaS requirements, and Appendix D - Sample Agreement.
6.1.2 Application Licenses
The Proposer shall supply the District with a license for accessing the software by District personnel and Water Customers. The application license shall cover read-only, read-write (where applicable), mapping and reporting activities (as required).
6.1.3 Active Directory
For all Utility Users, the application will allow for integration with the District’s Active Directory environment such as on-premise Active Directory, ADFS or Azure AD. The application will allow for multi-factor authentication (MFA) for all Utility Users if so desired by the District.
6.1.4 System Responsiveness
Proposer shall provide a system designed with capacity such that when connected directly to the system network, all users should experience reasonably response time to screen refreshes.
6.1.5 Support Term
The Proposer shall include ongoing annual support and maintenance for proposed solution. After the first year, the District will pay annual software support and maintenance or SaaS fees as detailed in the Compensation for a term of three years, with one (1) two-year optional extension. The Proposer must support the solution for a minimum of 10 years. Where new software application(s) are introduced that would render one of the applications proposed in
ACWD JOB 10062 Water Focused Customer Portal RFP 12
the Proposer’s solution obsolete, the new software shall have the same or improved functionality for the same or lower cost. The Proposer shall provide a minimum of a 12 month notice to move to a new software application.
6.1.6 Data Ownership
All data and information provided to the Proposer or generated by the solution is owned by the District. If requested in writing, the Proposer will provide all District data associated with the solution and meter or customer information provided from the CIS within 30 days. There will be no restrictions to the District in obtaining this data or additional costs associated with the transfer of this data.
6.1.7 Software Warranty
The Proposer shall warranty the application for its intended use for a period of 1-year duration as of the Go-live date. Any issues relating to the applications integration or functionality shall be investigated and resolved as part of the original implementation(no additional support costs).
6.1.8 District’s Existing IT Standards
The Proposer should conform (where applicable) to the IT standards described below. For an On-premise solution, where the proposed solution deviates from these, detail the difference within the technical submission.
Category Description
Server operating system Microsoft Windows Server 2016 or later
Virtual infrastructure VMWare
Databases supported SQL Server 2014 or later
Desktop operating system Windows 10 Enterprise
Office productivity software Office 2019/Office 365
Email system Exchange/Outlook
Browsers IE 11, Chrome, Edge
Supported browsers for external facing systems
All major browsers (IE, Chrome, Safari, Firefox etc.)
6.1.9 Software-as-a-Service
The sample SaaS agreement is attached as Appendix C - SAAS Requirement Form. It is the District’s intent to sign a separate long-term agreement to provide SaaS with the Proposer or the AMI Vendor who will continue to provide this service after Final User Acceptance Testing.
6.1.9.1 Browser Access
The software shall be accessible through the following applications (both desktop OS and mobile/tablet OS): the most recent versions of Microsoft Explorer, Microsoft Edge, Google
ACWD JOB 10062 Water Focused Customer Portal RFP 13
Chrome, Apple Safari, Mozilla Firefox. Additionally, the customer portal software should be available via native app for iOS and Android devices.
6.1.9.2 Service Level
The Proposer shall ensure the application availability (including all devices, collectors and reporting functional) aligns with Appendix C - SAAS Requirement Form. The system shall be available for District personnel and Customer use 24 hours a day, 7 days a week with a system uptime of 99.9% available.
6.1.9.3 Non-Production Environments
The software solution should include a full-time test environment where the District can perform testing. The test environment needs to replicate the production system but can be sized for a maximum of 60 days of consumption data. This test environment shall be available, at a minimum, during the initial standup and testing of the application.
6.1.9.4 Security
The Proposer is responsible for the security of the application and preventing unauthorized access to the District’s information.
6.1.9.5 Backup
The Proposer should back up the District’s data on a daily basis, storing the backup copy in a secure data warehouse separate from the active application(s). Recovery of any lost data should be completed within 3 days of the request by the District.
6.1.9.6 Hours of Support
As a part of its Software-as-a-Service offering, the Proposer shall provide phone support 24/7, 365 days per year.
6.1.10 Security
Proposer shall include evidence of information security consistent with industry standards via a written third-party assessment. Assessment shall include evaluation of external network penetration testing and a web application security assessment consistent with OWASP Top Ten principles. Export Control: Keeping utility data secure and private is a primary concern. To that end, data should not be exported outside of the United States. Specifically,
A. Data should not be transferred offshore for software development, testing, storage,
support or any other purpose B. Customer data should not be transferred across system boundaries in an unencrypted
fashion
C. All data transmitted between Proposer and a customer or cloud partner should
ACWD JOB 10062 Water Focused Customer Portal RFP 14
always be transferred in an encrypted fashion, using either SSL, SSH, PGP, or TLS as appropriate for the channel.
D. Proposer should use a certified third-party security firm to test external network
vulnerability.
6.2 Application Overview
6.2.1 User Definition
The AMI software shall allow for role-based user access such that users have appropriate access to the system based on their role in the system. The system shall allow for an unlimited number of roles to be District defined. At a minimum, the software shall allow access to the following types of Users:
A. Utility Users:
• Utility Administrator User: District employee(s) who have administrative access to the Customer Portal application for the purposes of authority to setup Users and make system wide changes.
• Utility User: District employees or external personnel to access the Customer Portal application for normal operations.
B. Water Customer Users setup in Cayenta as Customers that are categorized as follows:
Row Labels Description Total Accounts RES Residential 73,038 MULTI Multi-Family Residential 3,788 BUS Business 3,443 IND Industrial 1,084 XLDS Other Landscaping (Municipal, Religious, etc.) 764 RELDS Residential Landscaping 626 OTHER Other 579 BULDS Business Landscaping 427 UNOCCUPIED Unoccupied 369 INLDS Industrial Landscaping 322 HYD Hydrant 175 RESRT Residential Rental 66 WIND Wells Industrial 47 WMUNI Wells Municipal 15 MEDIC Medical (24-hour water supply) 9 WAGRI Wells Agriculture 9 WJUSE Wells Joint-Use 1 (blank) Residential Grand Total 84,762
• Residential Water Customers: individuals’ residential customers and irrigation
ACWD JOB 10062 Water Focused Customer Portal RFP 15
customers typically with water meter sizes 3/4” to 1”. • Commercial/Industrial and Institutional Customers: commercial (stores, multi-
residential, warehouse), industrial (manufacturing) and institutional (schools, government, hospitals) typically larger sized (1.5” and greater) water service.
6.2.2 AMI Business Drivers and Data
Appendix D - AMI Business Drivers includes a table with a detailed description of all the AMI business drivers the District determined were important to achieve with an AMI solution. It is expected that the described AMI business driver functionalities be achievable as outcomes of the project. In an effort to maximize the value of the solution, the District also identified opportunities for future enhancements. The customer portal is expected to provide a platform that will facilitate and support a number of these defined business drivers
6.2.3 Site Design and Startup
6.2.3.1 Branding
The application shall be designed to have the same look and feel of the District web pages, using the same logos, colors, fonts, formats and styles of the District.
6.2.3.2 Type of Device Detection
The application shall be able to detect the type of device (desktop, mobile or tablet application) the User is using to access the site and dynamically change formats to optimize the browser size of the device (laptop, tablet, smart phone).
6.2.3.3 Initial data population
The MDM will import 36 months of billed consumption from the CIS initially and on a continual basis. The customer portal will import all consumption data from the MDM, displaying up to 36 months of consumption data for comparison.
6.2.3.4 Ongoing data population
The customer portal will import and display billed consumption from the MDM on an ongoing basis, until AMI data is available. Then the AMI consumption from the MDM will be displayed in addition to the historical billed consumption prior to the AMI conversion.
6.2.3.5 Viewable customer data
Customers will be able to view only consumption associated with the current customer.
6.2.4 Support and Training
The application should include support and training (on-site as required) for District personnel. The intent of the training would be a train the trainer approach. The Proposer shall include call in support for District personnel between the hours of 9:00 AM and 4:00 PM PST.
6.2.5 Standards
All interfaces shall use HTTPS to communicate between applications.
ACWD JOB 10062 Water Focused Customer Portal RFP 16
Where credit card information is being collected the Proposer shall conform to PCI DSS security standard.
The Proposers solution shall be ADA compliant.
6.2.6 Integration with District Systems
The Proposer shall be responsible for developing and coordinating the integration effort between the Proposed water-focused customer portal and the existing systems discussed below. The Proposer will work with the District’s personnel and their external system providers to build the required interfaces between the systems and the proposed application.
6.2.6.1 Cayenta
The Proposer will build any required the water-focused customer portal side of the interface between the proposed application and Cayenta. The solution should replace all functions currently carried out by Cayenta Customer Self Service system. The District will be responsible for any development associated with the Cayenta side of this interface.
6.2.6.2 Invoice Cloud
The Proposer will build any required interfaces between the proposed application and the District’s Invoice Cloud application. This interface shall be a real-time interface (i.e. API) for all Invoice Cloud activities. The Proposer shall be responsible for both sides of this interface and where require, engage Invoice Cloud to successfully develop and test all interfaces required to achieve the functionality requested.
6.2.6.3 District Selected AMI System
The Proposer will build any required interfaces between the Proposed application and the District’s selected AMI system and MDM. The Proposer application shall accept and display both consumption information and any flags and alerts the AMI system makes available.
6.3 Customer Facing Functionality
6.3.1 Single Sign-On
The application shall have the ability to work with Invoice Cloud’s existing single sign-on (SSO) capability. The Proposer solution should be able to register water customers and use Invoice Cloud to authenticate the customer sign in. The SSO shall conform with Invoice Cloud’s single sign-on workflow detailed below:
CloudSSOConnect is Invoice Cloud's implementation of Single Sign On (SSO). SSO allows partners and/or billers to use Invoice Cloud to authenticate customers who use the partner/biller’s system, creating a seamless experience for customers between partner/biller and Invoice Cloud systems. Implementing CloudSSOConnect with their Invoice Cloud integration follows the workflow described below:
1. Partner/Biller makes a web service call to an Invoice Cloud Webservice. This web method passes user specific credentials to Invoice Cloud.
2. Invoice Cloud authenticates the credentials and returns a session-specific value to serve as a pointer to the customer’s unique Invoice Cloud session.
ACWD JOB 10062 Water Focused Customer Portal RFP 17
3. When the partner/biller is ready to redirect the customer to Invoice Cloud, they redirect the customer using a pre-defined URL. The customer can then navigate within the Invoice Cloud Customer Portal as needed.
Invoice Cloud can accommodate other custom integrations, but these may require different workflow steps in addition to those described above.
The proposed application shall allow the Customer to request or reset their login and password (via email or text) information without the need for District interaction with customers.
6.3.2 Multiple Water Accounts
The application should allow a Customer to connect to all accounts they are responsible for such that a single user can manage multiple accounts, preferably with grouping functionality that allows consumption from more than one account to be combined in a single view, or view accounts grouped by site location, where a Customer has multiple accounts at a single location.
The application should allow the Customer responsible for the account to setup multiple Guest users that allow them to use the system without being the person of record (example tenants, property manager).
The registration process should allow the Customer to either be setup directly with the application or through a single sign-on. This process of Customer registration or recovery of username(s) and password(s) shall require no intervention by District staff.
6.3.2.1 Cayenta Supplied Information
The application should allow the Customer to view Cayenta supplied information like customer, water meter, premise, bill (display) and payment history.
Where appropriate, the user interface and bills shall be dynamic that allows additional information and automatic links to make Customer navigation as simple and intuitive as possible.
6.3.2.2 Customer Supplied Information
The application shall allow the Customer to enter some optional demographic information about their family unit (number of members), their property (number of bedrooms, water fixtures, lawn size, etc.) and contact information (phone, email, text/SMS, etc.) and preferred communication method. Changes to this information should send a notification via email or text/SMS that will confirm the changes are approved.
The application shall allow logged in customers to be able to update the email address associated with the account.
6.3.2.3 Customer Help
The application shall include a Customer help module that supports and trains Customers
ACWD JOB 10062 Water Focused Customer Portal RFP 18
through the various functionality. The help module should include both printable materials, help video, frequently asked question or live chat with two-way live messaging. Live chat may allow service requests to be completed when the live chat functionality is unavailable (after hours). Customer help may also include ways to trouble shoot high consumption alerts for both indoor and outdoor water use.
6.3.3 View and Pay Water Bills
The proposed solution should allow the Customer to view their water bill and payment history and provide the Customer with the option to download their water bill in PDF.
6.3.4 AMI Consumption Views and Reports
6.3.4.1 Consumption Views
The application should allow the Customer to define dates (start and end dates) and granularity (monthly, daily, hourly consumption). The consumption data should allow the Customer to view the data in both graphical and tabular forms.
The application shall allow the Customer to view at least thirty-six months of consumption data.
The consumption should be able to be displayed in the Customer preferred unit of measure (cubic feet, gallons, etc.).
6.3.4.2 Consumption Comparisons
The application shall allow a Customer to compare their consumption with grouped average consumption. The application will allow the District to define the grouped averages that will be available to the Customer, which may include meter size, zip code, customer type, meter type, area, lot size, number of people per household, if they have a pool or irrigation, etc. The consumption should also import or synchronize temperature and precipitation data to overlay onto the consumption graphs.
6.3.4.3 Customer Reports
The application should allow the customer to download both graphical and tabular consumption reports in PDF and .csv / excel. The report should allow the Customer to select the starting and ending ranges and the granularity (annual, monthly, weekly, daily, hourly).
6.3.4.4 Validating, Editing and Estimation (VEE)
It is anticipated the AMI MDM will be able to perform some form of VEE; the application should display the difference between actual and estimated consumption data.
6.3.5 Customer Alerts and Notifications
6.3.5.1 Types of Customer Alerts
The application should include a number of alerts and events the Customer can configure. These alerts and events may include unusual consumption including continuous leak
ACWD JOB 10062 Water Focused Customer Portal RFP 19
detection (with configurable minimum hourly thresholds), unusually high consumption (i.e. 3 times more than average daily consumption) over a configurable number of days, vacation alert when consumption occurs during a configurable vacation date range.
6.3.5.2 Types of Notifications
The application should allow the customer to select their preferred type of notifications (email, text/SMS, phone call).
6.3.5.3 Customer Communications
The application should allow the District to communicate messages, programs, news flashes, emergency notifications, and other water related alerts (e.g. flushing in the neighborhood) to Customers. These can be passively displayed within the application or pushed out as an alert using the Customer’s preferred type of notifications.
6.3.5.4 Budget Billing
The application should include the ability for the Customer to setup water budgets and send notifications if consumption is above a Customer configured amount.
6.3.6 Global Customer Notifications
The proposed solution should allow the District to contact all or a subset of customer to communicate different types of water related information (boil water warning, water restrictions, conservation tips, etc.). The contact method would be dependent on the Customer preference and confirmation they are willing to receive such notifications.
6.3.7 Customer Service Requests
The application shall allow the Customer to make service requests both before and after the Customer sign-on process. New service requests shall be allowed prior to Customer sign-on. After sign-on, a Customer must be able to make maintenance requests related to water questions, meter maintenance, move in/move out and general requests. The District should have the ability to deactivate this functionality which will remove these tabs from the Customer’s view.
6.4 Utility Facing Functionality
6.4.1 Data and Access
The District should be able to view Customer or groups of Customer data to provide support to Customers. The application should allow District users to configure the Customer experience within the Customer modules. The District should be allowed to adjust or delete Customer information as required.
6.4.2 Consumption Views and Reports
The application should allow the District to modify or restrict any consumption reporting settings available to the Customer.
The application should allow the Utility representative to view what the Customer is viewing.
6.4.3 Alerts and Notifications
ACWD JOB 10062 Water Focused Customer Portal RFP 20
The application should allow the District to create alerts and notifications and set parameters around what type of functionality is available to Customers. These parameters may be different based on the customer type or meter size. The District should be able to setup global alerts that can apply to all Customers or a subset of Customers. The District should be allowed to determine which alerts are mandatory and which would require the Customer to sign up to receive them.
6.4.4 Analytics
The application should include a reporting or dashboard that shows the number of users who signed onto the Customer portal, how often they re-log into the system, type of functionality used, etc. to allow the District to better understand Customer interactions with the application.
The application should include a reporting or dashboard that shows the number of users who signed onto the Customer portal, how often they relog into the system, type of functionality used, etc. to allow the District to better understand Customer interactions with the application.
The District shall be able to download key customer information in an acceptable format (csv, excel, etc.).
6.4.5 Messages and Communications
The application should allow the District to create and distribute different types of communications to Customers either through a passive (posted on all customers’ module) or actively sending messages via the Customer preferred notification method.
6.5 Implementation and Training
6.5.1 Project Management
The Proposer shall assign a Project Manager (PM) to oversee all aspects of the application setup and configuration for the duration of the project. The PM will coordinate activities between stakeholders (District, Cayenta support, Invoice Cloud, AMI Contractor, contract administrator). The Project Manager shall be available, as required, in person to attend meetings with the District. The Project Manager should respond to all phone or email communication within 8 hours. Where an issue is deemed an emergency, the Project Manager is expected to respond to phone calls or email within two hours. The Project Manager will hold regular progress meetings and provide updates on coordinating activities required from all parties. The Proposer shall provide a teleconference / internet meeting to facilitate remote attendance for key stakeholders.
6.5.2 Business Requirements Meetings
The Proposer shall facilitate business requirements meetings with the key District and AMI Contractor staff to ensure the various options and alternatives are being presented for discussion and decision. The agreed upon Statement of Work will guide the business requirement meetings.
ACWD JOB 10062 Water Focused Customer Portal RFP 21
These meeting will be held at the beginning of the Proposer engagement so configuration and integration development achieves the needs of the District.
The Proposer shall document the outcome of the business requirements meetings and submit them for District review and approval within two weeks of the completion of the meetings.
6.5.3 Project Phases and Timelines
The Customer Portal setup and configuration will begin once the Proof of Concept Phase has been completed and approved by the District. Initial User Acceptance testing of the Customer Portal will be conducted during the AMI Project’s Production Phase and will use consumption data from the approximately 3,000 water meters installed during POC.
The highest ranked Proposer and District will engage in a design session in the context of contract negotiation prior to the District recommending an award of the contract. The District wants to ensure there are no gaps in a Customer’s current functionality and that the AMI data is understood by District staff prior to rolling the Customer Portal out to all Customers.
6.5.4 User Acceptance Testing
6.5.4.1 Types of User Acceptance Testing
All components of the application shall be tested and approved using a two-step User Acceptance Test (UAT). The UATs shall be conducted by the District with Proposer personnel in support of the testing process. The Initial User Acceptance Test (IUAT) will be used as the integration testing. It shall validate the software and interfaces are setup correctly and there are no major deficiencies that will result in incorrect information being passed to the customer portal application. The Final User Acceptance Test (FUAT) shall be performed on live information being passed to the customer portal from the various systems. The use cases will focus on customer experience functionality using approximately 180 days of real AMI data. Once the FUAT has passed, it will allow the District to make the customer portal application available to their Customers.
6.5.4.2 General User Acceptance Test Requirements
The Proposer shall develop and submit a UAT plans for both IUAT and FUAT for the District’s review and approval. The UAT plan shall document use cases for each scenario that will need to be tested, including what the expected result should be. A use case shall be deemed as passed if the actual results match the expected result. The District will review the submitted UAT plans and add any use cases that are missing or require more detail. The District must approve the UAT test plan prior to beginning the UAT. The test will be performed in both the District’s test system and the Proposer’s QA system. Once the IUAT has passed all use cases and the District approves, the Proposer shall be
ACWD JOB 10062 Water Focused Customer Portal RFP 22
allowed to move the customer portal application to the District’s production system. Initial UAT shall be approved (and software accepted) once the use cases are re-tested in the production environment. The FUAT will allow the District to make the customer portal application available to their Customers. The Proposer shall submit the documented results of the UAT for the District’s review and approval. The District may accept the UAT and approve the Proposer to move forward, may reject the UAT and require the Proposer to redo all or a portion of the testing, or may provide the Proposer with a conditional approval that details what the Proposer must complete to move forward. The UAT shall be the guide for all future testing on the project.
ACWD JOB 10062 Water Focused Customer Portal RFP 23
6.5.4.3 User Acceptance Test Responsibilities
The District shall provide the following to support the UAT: A. The billing test system for testing purposes. B. The AMI MDM system for testing purposes. C. Invoice Cloud system for testing purposes. D. Program any District side interface that connects to the CIS system. E. Coordination between the Proposer and the AMI Contractor.
The Proposer shall be responsible for all other roles and responsibilities including but not limited to:
F. Plan and schedule all the actions required for the UAT through the UAT plan. G. Coordinate and communicate with the Proposer and District personnel about the
progress and results of the UAT. H. Document the UAT plan and proposed UAT use cases. I. Setup a test system that will allow for a fully functioning system to conduct the tests. J. Document the use cases, the expected results and the actual results from the UAT. K. Keep a running numbered list of all software defects including date detected, date
fixed, retest dates, causes, and resolution description. L. Be responsible for supporting the District in resolving any issues with the District side
interfaces.
6.5.4.4 User Acceptance Test Documentation
The Proposer shall submit a UAT plan that shall conform to the following:
A. The Proposer shall submit a UAT plan for District review 40 days before the UAT is to begin.
B. The UAT plan shall include tasks to prepare for the UAT, a list of the use cases to be performed and who will be responsible for testing and validating the results.
C. The sequence of tests to be performed and duration of those tests. D. Identification of any District resources and services required to support the testing.
The Contactor shall submit an IUAT Use Case document:
E. The Proposer shall submit an IUAT use case document for District review 20 days before the UAT is to begin.
F. The IUAT use case document shall include a unique reference number to each use case, description of the use case, expected results, designated person to perform the test, person who will validate the test, the test accounts, test meters, and test AMI communication numbers to be used for each test.
G. The Proposer or the District may add use cases that were not included in the UAT plan as District deems necessary.
ACWD JOB 10062 Water Focused Customer Portal RFP 24
The Contactor shall submit a FUAT use case document:
H. The Contactor shall submit the final FUAT use case document (with results) for District review within five (5) days following the completion of the FUAT. During the testing period the Proposer shall communicate the results of the use case tests on a weekly basis.
At a minimum the FUAT use case documentation shall include:
I. IUAT use case document. J. The final FUAT use case documentation shall include the final results of each use case
include any details relating to any revisions or retests that were performed. K. The final FUAT documentation shall list the results of the test and, where a use case
did not pass list the deficiency.
6.5.4.5 Use Case Results and Deficiencies
The District shall track the results of use case testing. The acceptable states of a use case are:
A. Not Started: where the use case test has not yet begun. B. In Progress: where the use case in has started but the results are not in. C. Passed: where the use case actual results match the expected result. D. Passed with Note: where the use case actual result may not match the expected
result, but it has been deemed acceptable by District. E. Failed: where the use case actual results do not match the expected result and the
Proposer is investigating. F. Not Applicable: where District has deemed the use case to no longer be required.
Where a use case has Failed, the Proposer shall resolve the fault using the resolution process detailed in this section. Use case failures shall not be a reason for a delay claim. It is expected the Proposer will work with District to ensure the results meet the expected results.
G. A minor fault is a use case that fails to produce the expected result or the functionality to achieve the result is labor intensive, but the fault does not impact a Customer’s ability to use the customer portal.
H. A major fault is a use case that fails to produce the expected result or the functionality to achieve the result is very labor intensive, requiring eight (8) or more hours of effort each month and it affects a Customer’s ability to use key functionality of the customer portal.
The Proposer shall resolve a minor fault in the following manner:
I. The Proposer shall develop and test a resolution to a minor fault within 10 days of identifying the fault.
J. If the proposed resolution still fails, the Proposer shall develop and test a second resolution within 10 days of the second failure.
K. If the use case fails a third time, the District may consider this a major fault. L. A minor fault shall allow the UAT to continue moving forward. M. The Proposer may request additional time to resolve a minor fault; the District shall
review and may approve any such a request if they determine it will not have a major impact on the project as a whole.
ACWD JOB 10062 Water Focused Customer Portal RFP 25
The Proposer shall resolve a major fault in the following manner:
N. The Proposer shall develop and test a resolution to major faults within 5 days of identifying the fault.
O. If the proposed resolution still fails, the Proposer shall develop and test a second resolution within 5 days of the second failure.
P. If the use case fails a third time, the District may stop the UAT until the fault can be resolved and may request the entire UAT be redone once the fault has been resolved.
Q. A major fault shall not allow the UAT to continue moving forward. R. The Proposer may request additional time to resolve a major fault, the District shall
review and may approve any such request and may put work restrictions on the Proposer up to and including a full stop on part of all of the project tasks.
6.5.4.6 Specific User Acceptance Test Requirements
The Proposer shall provide a list of recommended use cases to the District for review. The District will review, revise and add use cases they deem as important.
6.5.5 Training
The Proposer shall provide on-site training to the District’s billing and customer service personnel (approximately 20 personnel) and provide additional intensive training to three District designated Train the Trainers. This intensive training will include a test to ensure the training has been retained and the designated personnel are proficient to train future District personnel on how to operate the customer portal. All training will be provided by an expert who has extensive knowledge of the Customer portal. Training will take place between the hours of 9:00AM to 12:00PM and/or 1:00PM to 4:00PM with a 15-minute break for each three-hour session. The Proposer shall supply any training materials that will be required to provide the training. The District will provide training rooms that include chairs, tables, computers and access to the application required for the training. The training will have a maximum class size of six (6) people with no more than 2 people from each department participating. It is expected the same training will be required at least four different occurrences to ensure there are no staffing issues to cover the regular department functions. The Proposer shall provide a detailed training agenda at least 15 days prior to the training occurring. The Proposer shall provide full color manual to each person attend the training sessions as well as digital copy of the manuals on thumb drive. The District reserves the right to videotape the training for future use.
ACWD JOB 10062 Water Focused Customer Portal RFP 26
7.0 ADDITIONAL REQUIREMENTS
7.1 California Consumer Privacy Act
The Proposer will ensure all software, systems, products, and installation processes comply with California Consumer Privacy Act (CCPA).
7.2 Information Protection and Personal Privacy
The Proposer shall protect and maintain strict confidentiality for all personal information it manages including but not limited to the names, account numbers, addresses and phone numbers (if applicable) of customers and consumption information.
The Proposer shall only use personal information for the purpose of the defined work. Any list that contains personal information for the purpose of performing the work or otherwise shall be kept secure and destroyed after use.
8.0 COMPENSATION
The selected Proposer will be compensated for services based on a combination of milestones, time and materials, and a subscription basis. Progress payments will be based on individual hours billed to individual tasks plus allowable expenses. Compensation for sub-consultants and/or contractors will be limited to the same restrictions imposed upon the selected Proposer.
During implementation of the water-focused customer portal, the selected Proposer shall invoice ACWD for its services by task on a monthly progress payment basis with the actual resources utilized per task. SaaS or support and maintenance services progress payments will be made on an annual basis at the beginning of the service period.
The Proposer shall complete the Cost Proposal table that is broken into three sections: 1) Implementation Services Costs, 2) Software-as-a-Service (SaaS) Costs, and 3) Total Solution Cost. The Implementation Service will be delivered with a not-to-exceed cost ceiling. The SaaS costs should assume
1) Implementation Services – implementation services shall include all planning, business requirements, integration development, testing and overall coordination activities.
a. Cost by Task / Subtask
The Task/Subtask cost shall consist of a breakdown of each work task/subtask that includes an estimate of total person-hours for each project team member and/or sub-contractor, and associated unit costs, as appropriate (e.g. hourly charges for personnel).
b. Cost – Total Implementation Cost The lump sum sub-total for all non-optional tasks (i.e. Total Project Cost) shall be
tabulated. Additionally, the grand-total for all the entire scope of work shall be tabulated.
c. Hourly Rate Schedule:
ACWD JOB 10062 Water Focused Customer Portal RFP 27
The selected Proposer shall submit a schedule of charges with the cost estimate. Hourly base rates for personnel, equipment, and sub-consultants shall be all inclusive of overhead for staff overtime, per diems, mobilization of personnel and equipment, test equipment, health and safety equipment, design equipment, office services and equipment, transportation costs, report preparation, permitting meetings, administrative charges, and other miscellaneous expenses, as they apply to the project.
d. Milestone Payments: The Implementation Service costs shall include proposed milestones that is between
25% to 50% of the total Implementation Services cost. ACWD reserves the right to adjust the definition, percentage or number of milestones proposed during contract negotiations.
e. Disbursements: The Proposer shall include a total upset limit for travel, on-site meals, lodging, vehicle
expenses. All costs will be reimbursed on an actual cost basis.
2) Software-as-a-Service (SaaS) Subscription Fees – SaaS costs shall include all fees related to hosting and serving the application, maintenance of interfaces, application patches, upgrades, and on-going support services and training.
a. Subscription fees: Following the expiration of the one (1) year application development Warranty Period SaaS subscription fees shall be invoiced annually and will be based on the total active meters at the end of the completed year. Any new water system connections added to ACWD service area will be invoiced on this schedule.
b. Annual Adjustments: The Proposers fee schedule, per meter, for years one (1) through ten (10) of the SaaS service shall be firm and include all necessary annual adjustments.
c. Contract term: The District intends to award the contract with a three (3) year base SaaS term, with the option to extend for two (2) additional years.
3) Total Solution Cost – is the total cost of Implementation Services plus ten years of SaaS fees for 85,000 meters.
a. Subscription Increases: The Proposer shall hold per meter subscription fees for a period of three years and then may propose an annual percentage fee increase for years 4 to 10.
b. Total Solution Cost: The Proposer shall fill out the following table based on the proposed Implementation Services Cost and SaaS Fees.
ACWD JOB 10062 Water Focused Customer Portal RFP 28
Description Cost
Implementation Services Costs $
SaaS Subscription Fee Year 1
$
SaaS Subscription Fee Year 2
$
SaaS Subscription Fee Year 3
$
SaaS Subscription Fee Year 4
$
SaaS Subscription Fee Year 5
$
SaaS Subscription Fee Year 6
$
SaaS Subscription Fee Year 7
$
SaaS Subscription Fee Year 8
$
SaaS Subscription Fee Year 9
$
SaaS Subscription Fee Year 10
$
Ten Year Total Solution Cost $
ACWD JOB 10062 Water Focused Customer Portal RFP 29
9.0 PROPOSAL ELEMENTS
9.1 Instructions
These instructions prescribe the mandatory proposal format and the approach for the development and presentation of proposals. The Proposer shall carefully examine the RFP and be satisfied as to the conditions to be complied with, prior to the Proposer submitting a proposal. The District may reject, at its sole discretion, any Proposal submissions that deviate from these instructions.
Proposals shall be prepared simply and economically, providing a straightforward and concise description of how the proposal has satisfied all the requirements of this RFP. Proposals shall incorporate all proposal elements identified in the RFP, including all required forms provided in the appendix of the RFP Documents. All blank spaces on all forms shall be properly filled in; and any interlineations, alterations or erasures shall be fully explained and initialed by the Proposer. Proposals shall be properly executed. Partial or incomplete Proposals will not be considered. Proposals shall be in strict conformity with the RFP Documents and any addenda thereto. Emphasis shall be on completeness and clarity of content with sufficient detail to allow for accurate evaluation and comparative analysis. Excessive or irrelevant materials will not be favorably received.
It is the Proposer’s responsibility to ensure that its Proposal is submitted in a manner that enables the District’s Evaluation Team to easily locate all response descriptions and exhibits for each requirement of this RFP. Page numbers should be located in the same page position throughout the proposal. Figures, tables, charts, etc., should be assigned index numbers and should be referenced by these numbers in the proposal text and in the proposal Table of Contents.
Proposal terms and pricing shall be firm for one hundred and eighty (180) calendar days from RFP Closing date specified.
The following information must be included on each page of the proposal:
• Proposal for Water Focused Customer Portal
• Job No. 10062
• October 2019
• Unique page number
ACWD JOB 10062 Water Focused Customer Portal RFP 30
9.2 Proposal Structure
The Proposer must structure their proposal as a response to the instructions and questions detailed below. Proposals shall be no more than 50 pages, not including the table of content, resumes, forms and any proposal appendices. The font should be no smaller than 11 pt. The proposal shall contain the following Sections:
Proposals shall be organized in the following manner to help facilitate evaluation. Proposers are requested to format proposals with 12 sections in a question and answer format. At a minimum, each section of the proposal should include responses to the questions outlined below.
Evaluation of each proposal will be based on the responses provided within the body of the proposal itself. Supporting documents such as resumes, product literature/specifications, warranty statements, project schedule, etc. may be included in an appendix and will also be considered when evaluating question responses. Solely providing product brochures and/or websites will not be considered as an appropriate response to these questions.
Proposals should indicate compliance with the outlined specifications and addendums. Where exceptions to the specifications are proposed, the Proposer must clearly state what exceptions are being made, the reason for the exception, and the proposed Alternative Solution. The District may disqualify the Proposal from further evaluation depending on the nature of the exception. To avoid this circumstance, Proposers should provide any proposed exceptions in writing to the District prior to the deadline for questions.
Section 1: Submittal Forms
Complete Appendix A – Technical Proposal Submittal Form
Complete Appendix B – Cost Proposal Submittal Form
Section 2: Letter of Introduction
This introduction letter is intended to be a brief overview (should be a maximum of 3 pages).
1. Proposers must provide a brief profile of the company submitting the proposal. List the length of time in business, the principals involved in the submission.
2. Provide a primary contact including name, title, address, phone number and email.
3. The Proposer must identify those persons who are authorized to negotiate on their behalf with the District.
4. Provide the name and version of the proposed water-focused Customer Portal.
5. Proponents shall disclose any sub-contractors that they propose to employ in the performance of this contract. Sub- contractors may not be changed after award of the Contract without written permission from the District.
ACWD JOB 10062 Water Focused Customer Portal RFP 31
6. Proponents are required to state any perceived or actual conflicts of interest that they might have with the District or their staff.
Section 3: Solution Overview
Based on the available existing information, the proposal shall clearly communicate the Proposer’s proposed approach to accomplishing the Work. The Proposer should communicate their understanding of the Project through a discussion of the project requirements.
7. Provide an overview of the proposed water-focused customer portal solution considering the requirements outlined in Section 6.
8. Describe if your solution is based on a SaaS and/or on-premise model and include relevant details to help the District evaluate the benefits of your proposed approach.
a. Is the solution hosted (single tenant) or SaaS(multi-tenant)?
b. Provide a description of the solution disaster recovery plans.
c. Describe the platform application security and architecture.
9. Summarize the value proposition of the proposed solution and what differentiates your solution.
Section 4: Application Overview
10. Provide a description of the different types of users who will access the application.
11. Achieving the AMI business drivers is critical to benchmarking the success of the AMI deployment and the customer portal. Detail how your proposed solution can help the District achieve their Customer Portal Goals as outlined in section 4 of this RFP. Provide case study examples where possible.
12. Provide details on the Proposer’s ability to satisfy site design requirements outlined in Section 6.2.3. Can the District Users adjust the site design, or does this need to be performed by the Proposer (i.e. after go-live)?
13. Confirm the proposed solution meets all the required standards discussed in Section 6.2.5.
14. Provide a proposed system architecture diagram that includes the proposed application, other systems (Cayenta, AMI System, Invoice Cloud, etc.) and the various interfaces that will be required. For each interface indicate the direction and type of interface proposed.
15. Provide a list of utilities who utilize Cayenta and/or Invoice Cloud and have had the proposed application successfully interfaced.
16. Confirm the solution can eliminate Cayenta’s Customer Self Service module and suppress the Invoice Cloud functionality through the use of API(s) or other approved method.
17. On average, how many major versions of the software are released each year? Provide a list of the updates that have occurred in the last three years.
18. Provide a future development roadmap for the proposed solution.
19. Is GIS integration on the development roadmap?
ACWD JOB 10062 Water Focused Customer Portal RFP 32
20. Describe the benefits of GIS integration.
21. Can the District use SQL reporting services to support District developed queries to extract data?
22. Describe the technical details of the self-service “forgot your password” process, considering the required SSO integration with Invoice Cloud.
Section 5: Customer Facing Functionality
23. Provide a storyboard of the Customer Experience using the proposed application. Include screenshots and a description of the different functionalities.
24. Provide details of the application’s single sign-on capabilities and how they satisfy the District’s requirements.
25. How can water customers access the proposed solution (desktop, mobile/tablet, IOS/Android applications)?
26. Outline the application’s capabilities with respect to the defined requirements for registration and basic information as outlined in Section 6.3.
27. Describe how a single customer user can link numerous accounts into the single login event.
28. Provide an overview of your consumption view and reporting capabilities. Describe your capabilities to meet and/or exceed the described requirements in Section 5.3.2. Provide sample reports or screenshots examples.
a. Is there a way to overlay weather data over consumption?
b. Does the application have vacation alerts that allow the customer to get notified of consumption occurring while on vacation?
c. Can the customer compare their consumption for a specific period of time to other periods, or similar customer average for the same period?
d. Will AMI Usage Alerts / Alarms be displayed in the Customer Portal?
29. Describe your application’s ability to provide customer alerts and notifications (refer to Section 6.3). Provide case study samples. Describe any lessons learned or best practices for maximizing the effectiveness of these features.
30. Explain how your application handles customer service requests and outline your ability to satisfy or exceed the requirements in Section 6.3.
a. What type of service requests/complaints can a customer perform (e.g. move-in / move-out)?
b. Is there a way for the customer (not logged in) to request new services?
Section 6: Utility Facing Functionality
31. Provide a storyboard of the Utility Facing Experience using the proposed application. Include screenshots and a description of the different functionalities.
32. Outline the application’s capabilities to restrict certain functionality based on the different types of customers.
ACWD JOB 10062 Water Focused Customer Portal RFP 33
33. Confirm if the Utility User can also view what the customer is viewing as a means to help support the customer during a call?
34. Does the solution support an audit trial (what was changed by who and when)?
35. Describe your applications ability to provide global alerts / notifications to all customers or a subset of customers (i.e. residential, commercial, irrigation, etc.).
36. Provide details on your application’s analytics capabilities and the available reports to allow the District to understand customer’s behavior on the portal.
37. The application should allow the District to create and distribute different types of communications to customers either through a passive (posted on all customers’ module) or actively sending messages (on-line chat) via the customer’s preferred notification method. Describe how/if your solution can support these requirements.
38. The portal should have the backend ability to take the MDMS data and apply algorithms to identify patterns of excessive use such as over-irrigation, leaking / running toilets, other high use patterns, then alert the customer and present or call out anomalies in use on the consumption display or other display in the portal when they sign in.
39. The Utility should have the ability to run reports against the high use patterns described in the prior question.
40. The portal should have an area for messages / conservation recommendations. Describe this function, if available.
41. The recommendations for program and water savings should display based on use patterns (anomalies, high use during certain times of day, potential leaks). Describe this function, if available.
42. The portal should have the ability to communicate leaks, over-irrigation, high consumption to customers via a variety of communication methods, most importantly text and email.
Section 7: Implementation and Training
43. Provide an organization chart for the proposed Project team. The organization chart shall clearly identify the Project Manager who will be the District’s main point of contact. Provide a brief description of the key personnel and their corresponding responsibilities.
44. Provide a project plan with key milestones and major tasks to successfully complete the work described in the RFP. At a minimum, the project schedule shall be presented as a Gantt chart and shall detail the time requirements for each of the major tasks. Where appropriate, each work task and/or subtask shall be broken down into subgroups and included in the schedule. Responsibilities associated with the District should also be defined.
45. Describe the proposed approach to achieving the requirements for User Acceptance Testing as outlined in Section 6.5.4. Provide case study examples where similar practices were applied and describe the results.
46. Effective and relevant training is highly valued by the District. Detail the training that will be conducted (who will be required, when and where it will be conducted, how long it will be, what materials will be handed out) in order to prepare the District to use the application as well as prepare the “Train the Trainers”.
47. The Proposer shall discuss their strategies to be on time and within budget.
ACWD JOB 10062 Water Focused Customer Portal RFP 34
48. Provide a sample (as an appendix – not included in page count) Statement of Work that would be the starting point of negotiation. Where the Statement of Work will be developed after award, provide a description of the proposed process for documenting the statement of work.
Section 8: Experience and References
49. It is highly desirable that the Proposer have a minimum of 5 years of industry experience. Describe the Proposer’s history in providing the proposed solution. Provide a statement of experience with a brief listing of company experience focusing on work of similar scope.
50. Proposer is requested to provide at least three references for water utility customers where similar programs have been implemented using the proposed application. References must include Utility, program manager name, title, and contact information as well as the specific project dates, number of water meters under management, short description of program, time to launch (contract signing to start of program) and results.
51. Identify the Project Manager and lead technical person (or persons) and provide a short narrative of their prior project experience that may have value to successfully completing the work described in the RFP, including experience on similar assignments.
52. Proposer’s key project team staff shall be competent at executing the various elements of work described in this RFP. Resumes for key staff including the Project Manager shall be included in an appendix to the proposal (including name, role, location, education, tenure, qualifications and experience with similar projects).
Section 9: Value-Added Solutions
The District encourages Proposers to provide innovative solutions to complete all aspects of the project. Proponents may provide value-added items at their discretion. Such offerings will be reviewed and finalized once the preferred Proposer has been selected. Proponents should provide the technical merits of value-added solutions in their proposal to allow for consideration and evaluation. Any financial impacts related to value-added solutions shall also be discussed.
Section 10: Cost Proposal
Include Proposer’s Cost Proposal (as required in Section 8, Compensation as outlined in this RFP).
Section 11: Exceptions to the Sample Agreement / Software-as-a-Service (SaaS) Requirements
Exceptions to the District's Sample Agreement / Software-as-a-Service (SaaS) Requirements (Appendix C) shall be identified and included in the proposal. Noted exceptions will be considered in the evaluation process.
Listed Exceptions to Section 6, Scope of Work and Submission Requirements as outlined in this RFP).
Section 12: Resumes of Key Proposed Staff
Include resumes as requested.
Section 13: Appendices (Optional)
Include tables, diagrams, figures, exhibits and/or maps.
10.0 PROPOSER’S QUESTIONS
ACWD JOB 10062 Water Focused Customer Portal RFP 35
Proposer’s questions shall be directed to:
Contact: Benjamin Egger, Project Engineer Address: 43885 South Grimmer Boulevard, Fremont, California, 94538 E-mail: [email protected] Phone: (510) 668-4482
All Proposer’s questions relative to the RFP Documents shall be submitted via e-mail by 5 p.m., Pacific Standard Time (PST), October 23, 2019. Should the answer to a Proposer’s question require a modification to the RFP Documents, such modification will be made by issuing addenda as specified in Part 11.0 DISTRICT’S MODIFICATION OF RFP DOCUMENTS. Responses to questions not requiring modifications to the RFP Documents will be posted to the District website (www.acwd.org) and sent to all Proposers registered on the RFP Holders List.
11.0 DISTRICT’S MODIFICATION OF RFP DOCUMENTS
The District expressly reserves the right to modify any provision or part of the RFP at any time. Receipt and evaluation of proposals does not obligate the District to award a contract. Any change to this document shall be made by written addendum by the District. Only changes provided via by addendum will be binding on the District. Addenda will be posted on the District’s website site under “Current Consultant & Services Opportunities” (www.acwd.org). Any addenda issued shall be considered part of this RFP. Any proposal may be withdrawn at any time before the proposal deadline date and time specified in Section 13.0 – Submission of Proposals, by providing written request for the withdrawal of the proposal to Ed Stevenson, Engineering & Technology Services Manager. The request shall be executed by a duly authorized representative of the Proposer’s company. 12.0 WITHDRAWAL OF REQUEST FOR PROPOSALS
A Proposer may, without prejudice to itself, withdraw its Proposal by written request, provided that the request is received by the District at the place where the Proposals are to be submitted prior to the specified closing time. The request shall be executed by a duly authorized representative of the Proposer’s firm. No Proposal may be withdrawn after the time specified for closing of Proposal. The Proposer withdrawing its Proposal may submit another Proposal prior to the closing time specified.
13.0 SUBMISSION OF PROPOSALS Ten (10) paper copies and three (3) USB memory stick copies of the proposal, provided in PDF format, shall be submitted in a sealed envelope marked: “Water Focused Customer Portal, Proposal Submission, ACWD Job 10062”.
The proposal shall bear the name and address of the Proposer and be delivered to:
Contact: Ed Stevenson Address: 43885 South Grimmer Boulevard, Fremont, California, 94538 Phone: (510) 668-4482
ACWD JOB 10062 Water Focused Customer Portal RFP 36
The proposal may be delivered in person to the District (receptionist at the front desk) or by the use of a courier service or mail. Proposers mailing proposals should allow appropriate mail delivery time to ensure timely receipt of their proposals and assume the risk of late delivery. It is the responsibility solely of the Proposer that its Proposal is submitted in proper form and prior to the stated closing time.
Proposals received after 2:00 p.m., PST, October 31, 2019, will be returned to the Proposer unopened.
Material submitted by the Proposer shall become the property of the District unless otherwise specified. All proposals may be reviewed and evaluated by any person at the discretion of the District.
14.0 EVALUATION OF PROPOSALS
14.1 Instructions
Complete, responsive Proposals received will be evaluated by the District’s Evaluation Team. During the evaluation process, the District has the right to request any clarification or change it needs to better understand the proposal, to negotiate with any individual(s) or qualified firm(s), to request revised proposals, to visit the Proposer(s)' site(s), to interview or not, if it is in the best interest of the District to do so. Any changes to the proposal of the selected Proposer will be made before executing the contract and will become part of the contract.
The District also reserves the right to waive any non-material irregularities in any proposal. If a contract is awarded, it will be awarded to the highest ranked Proposer determined to have the best value solution that meets the District's needs in accordance with the Proposal Evaluation process. All Proposers will be notified of the result of the selection process.
Selection will be made on the basis of the District’s judgment as to which proposal best serves the District’s interest.
14.2 Evaluation Process
All accepted proposals will be reviewed by the District’s evaluation team. Any proposals received after the due date or proposals that have not met the minimum requirements as set out in Appendix A or are otherwise non-responsive will not be evaluated.
The evaluation team will take the following steps when evaluating the proposals. The District may deviate from this process when it deems it is in its best interest to do so.
A. The evaluation team members will review the submitted proposals. B. The evaluation team will review the proposals and document any questions for the
Proposers.
C. The evaluation team will hold an evaluation meeting with its team members to review and discuss the responses. The consensus score will be summed to determine the Technical Score.
D. The evaluation team will firm up an on-site demonstration/ interview schedule with
compliant Proposers who achieve the minimum benchmark, described below, for the technical score.
ACWD JOB 10062 Water Focused Customer Portal RFP 37
E. Proposers will attend an on-site demonstration and interview. It is expected that the proposed Project Manager be on-site during this presentation. Following the demonstrations, the evaluation team will review and discuss the demonstration and interview responses. The consensus score will be summed to determine the on-site demonstration and interview score.
F. Following the on-site demonstration and interview, the District will review the Total Cost
Solution for all Proposers. See 12.3 Evaluation Criteria for reference.
G. The evaluation team will submit its recommendation for contract award, if any, to the Board of Directors. If a contract is awarded, it will be awarded to the responsible Proposer submitting the proposal with the best value solution based on the evaluation criteria set forth below and provided that the Proposal complies with the specified requirements; is reasonable; and is in the best interest of the District to accept.
14.3 Evaluation Criteria
Each Proposal will be evaluated on the basis of its technical and financial merits. All Proposals will be reviewed to determine compliance. The District requires an innovative and cost-effective solution and will judge each proposal using the evaluation criteria detailed below as a guide. The technical evaluation will be evaluated based on the categories and weighting detailed below. There will be a total of 2,000 available points in the evaluation:
• Technical Points (1,000), • On-site Demonstration and Interview Points (600), and • Cost Proposal Points (400).
ACWD JOB 10062 Water Focused Customer Portal RFP 38
Category Description Sub-Categories Technical 1. Letter of Introduction N/A
2. Solution Overview
Overview and requirements
100 Benefits of proposed approach Value proposition
3. Application Overview
User requirements
200 AMI Business Drivers Site design requirements Integrations Single sign-on
4. Customer Facing Functionality
Registration and Basic Information
200 Consumption view and reporting Customer alerts and notifications Customer Service Requests
5. Utility Facing Functionality
Data access
150 Consumption view and reporting Alerts and notifications Analytics Messages and communication
6. Implementation and Training
Project team
150 Project plan and timelines User acceptance testing Training
7. Experience Industry experience
150 Project Manager Experience Resumes
8. Value-Added
50
Technical Points Any proposals where the evaluation does not receive the minimum benchmark of 600 of the available 1,000 Technical points will not be short-listed for an on-site demonstration and interview and will not have their Cost Proposal submission reviewed.
1,000
On-Site Demonstration and Interview Points 600
TOTAL TECHNICAL SCORE Technical Points + Demonstration and Interview Points (score out of 1,600)
1,600
ACWD JOB 10062 Water Focused Customer Portal RFP 39
The team will score the responses to the questions posed in Section 8 using the following scoring descriptions.
Evaluator Scoring
0 Did not respond to question(s)
2 Some expectations were met
5 Most expectations were met
7 All expectations were met
10 Exceeded expectations
14.4 On-site Demonstration and Interview
All Proposers who meet the minimum benchmark for the Technical Points will be requested to provide an on-site demonstration and interview. The demonstration/interview will take place at a District facility. Estimated time for the presentation will be 90 minutes long with the last 30 minutes being for the evaluation team to ask questions. The District will schedule a time once the list of Proposers is known. The demonstration/interview will provide an overview of the solution and demonstrate in a live test system certain aspect of the application based on a District predefined script. A detailed agenda and a list of questions will be provided prior to the meeting.
14.5 Financial Evaluation
The Total Cost Score will be based on 400 available points based on the following formula:
Total Cost Score = 400 * (Lowest Total Solution Cost / Proposer’s Total Solution Cost)
14.6 Total Evaluation
The Total Evaluation Score will be calculated as follows:
Total Technical Score + Total Cost Score = Total Evaluation Score
District staff will present the highest ranked proposer (the proposer with the highest Total Evaluation Score) to the board for approval. Negotiations will take place with this highest ranked proposer.
14.7 Statement of Work
The District will negotiate the final Statement of Work with the Preferred Proposer.
ACWD JOB 10062 Water Focused Customer Portal RFP 40
15.0 PROPOSER SELECTION SCHEDULE (SUBJECT TO CHANGE) The District’s selection schedule is listed below. Proposers shall ensure the availability of resources, as necessary, and facilitate work to meet all District imposed deadlines set forth herein.
Proposer Selection Schedule (Subject to Change)
Release Request for Proposals October 7, 2019
Preproposal Conference 10:00 a.m. PST October 16, 2019
Deadline for Questions & Clarifications from Proposers 5:00 p.m. PST, October 23, 2019
Proposals Closing Date 2:00 p.m. PST, October 31, 2019
On-site Demonstrations / Interviews December 9 - 13, 2019
Statement of Work Negotiation January 6 to 24, 2020
Recommendation of Award to the Board February 13, 2020
Anticipated Notice of Award February 14, 2020
16.0 CONFIDENTIALITY All responses to this RFP become property of ACWD and will be kept confidential until a recommendation for award of a contract has been announced. Thereafter, submittals are subject to public inspection and disclosure under the California Public Records Act (Cal. Govt. Code Sections 6250 et seq.). Therefore, unless the information is exempt from disclosure by law, the content of any proposal, request for explanation, exception, or substitution, response to these specifications, protest, or any other written communication between ACWD and any Proposer regarding the procurement, shall be available to the public. Proprietary information should be clearly identified so that it may be kept confidential. All other parts of the proposal are public records after the recommendation for award of a contract has been announced.
17.0 JOINT PROPOSALS Proposals submitted by a joint venture will be considered only if:
• The Proposers have obtained or will have obtained at the time of award of the Contract a contractor’s license for the joint venture from the California Contractor’s State License Board, and;
• The Proposers have filed with the District before the stated closing time an affidavit of joint venture on the District’s form which is available from the District upon request.
ACWD JOB 10062 Water Focused Customer Portal RFP 41
18.0 INSURANCE The Proposer shall obtain and maintain in full force and effect at all times during the prosecution of the Work and until the final completion and acceptance thereof the following insurance coverages with the limits as specified. Such insurance shall be maintained without interruption and at Proposer’s sole expense. Each insurance carrier must have an A.M. Best’s rating of “A-VII” or better and be a California-admitted carrier or a carrier authorized to do business in California.
Proposer shall contractually require that each of its subcontractors and anyone else for whose acts any of them and/or the District may be liable secures and maintains without interruption the same insurance described herein.
A. Commercial General Liability Insurance
The Contractor shall obtain and maintain commercial general liability insurance that shall protect the District, its directors, officers, employees, agents, and volunteers from claims which may arise in connection with operations related to this Contract, whether such operations are by Contractor, by any subcontractor or consultant, or by anyone directly or indirectly employed by Contractor, a subcontractor, or a consultant. Such insurance shall cover all operations by or on behalf of District for liability for:
• bodily injury (including but not limited to sickness, disease, and death);
• broad form property damage (including but not limited to physical injury to tangible property and resulting loss of use of that property and loss of use of tangible property that is not physically injured, and extending to property under the care, custody, and/or control of an insured); and
• personal and advertising injury (including but not limited to false arrest, false detention, false imprisonment, malicious prosecution, defamation, slander, and libel);
for the limits of liability indicated below. Coverage shall be primary and non-contributory and written on an occurrence basis, and this insurance shall also include coverage for the following:
• premises – operations;
• independent contractors;
• products completed operations hazards;
• duty to defend all insureds;
• deletion of any limitation on coverage for bodily injury or property damage arising out of subsidence or soil or earth movement;
• XCU – explosion, collapse, underground damage; and
• blanket contractual liability – provision or endorsement shall state that the insurance, subject to all of its other terms and conditions, applies to the liability assumed by Contractor under this Contract, including without limitation insurable liabilities set forth in the indemnity sections of this Contract.
ACWD JOB 10062 Water Focused Customer Portal RFP 42
Except with respect to bodily injury and property damage included within the products-completed operations hazards, the aggregate limits where applicable, shall apply separately to Contractor's work under this Contract.
This liability insurance shall be in amounts not less than the following limits:
• each occurrence limit - $2,000,000;
• general aggregate limit (other than products-completed operations) - $4,000,000;
• products-completed operations aggregate limit - $2,000,000; and
• personal and advertising injury limit - $1,000,000.
If the policy does not provide, whether by endorsement or otherwise, that the aggregate limits apply separately to this Project or if defense costs are included in the aggregate limits, then the required aggregate limits shall be $2,000,000. Permission is granted for deductible which shall not exceed $25,000 without approval of the District. The Contractor shall be responsible for paying any and all deductible costs.
B. Automobile Liability Insurance - Comprehensive Form
The Contractor shall obtain and maintain automobile liability insurance (covering bodily injury and property damage liability) including coverage for all owned, hired, rented, leased and non-owned automobiles. The limits of liability shall be not less than:
• combined single limit for each accident/occurrence - $2,000,000; and
• combined single limit for each accident/occurrence for projects on public roadways - $5,000,000.
C. Umbrella/Excess Liability Insurance
Contractor may use an umbrella or excess policy to meet the above commercial general liability insurance limits requirements, but any such umbrella/excess policy must be issued by a California-admitted carrier or a carrier authorized to do business in California with an A.M. Best’s Rating of “A-VII” or better.
D. Worker’s Compensation and Employers’ Liability Insurance
The Contractor shall obtain and maintain workers compensation and employers’ liability insurance for all its employees on the Project in strict compliance with applicable law and with the following limits:
• worker’s compensation – statutory; and
• employers’ liability – $1,000,000 each accident for bodily injury by accident;
- $1,000,000 each employee for bodily injury by disease; and
- $1,000,000 policy limit for bodily injury by disease.
ACWD JOB 10062 Water Focused Customer Portal RFP 43
Such insurance shall include endorsements from the insurer agreeing to waive all rights of subrogation against the District, its directors, officers, employees, agents, and volunteers which might arise by reason of any payment under such policies.
E. Professional Liability Insurance
CONTRACTOR also shall maintain Professional Liability Insurance covering CONTRACTOR’s performance under this Agreement with a limit of liability of One Million Dollars ($1,000,000) for any one claim.
F. Network Security and Privacy Liability
Network Security and Privacy Liability insurance for the duration of this agreement providing coverage for, but not limited to, Technology and Internet Errors & Omissions, Security and Privacy Liability, and Electronic Media Liability. Insurance will cover claims that arise from the disclosure of private information from files but not limited to: 1) the errors or omissions of the Proposer, its employees or Sub-contractors and 2) penetration of the Proposer’s electronic data network, “firewall” or other security devices by hackers or others. The insurance policy should provide minimum coverage in the amount of $1,000,000 per occurrence and $2,000,000 annual aggregate. If written on a Claims-Made basis, the policy must provide an extended reporting period and have a retroactive date that on or before the date of this Contract or the date Proposer commences work, whichever is earlier.
Within fifteen (15) days after receipt of the District’s Notice of Award, the Proposer shall deliver to the District certificates of insurance evidencing issuance of all insurance identified herein, copies of the policy declaration or information page(s), additional insured endorsements, and waiver of subrogation endorsements. The certificate(s) and endorsements for each insurance policy are to be signed by a person authorized by that insurer to bind coverage on its behalf. The endorsements are to be on endorsement forms acceptable to the District. The certificate(s), policy declaration or information page(s), and endorsements are to be received and approved by the District before the Work commences. Proposer shall also provide certificate(s) evidencing renewals of all insurance required herein, at least thirty (30) days prior to the expiration date of any such insurance.
Acceptance of the certificates shall not relieve the Proposer of any of the insurance requirements, nor decrease the liability of the Proposer.
District may request a copy of any insurance policy required herein at its sole discretion and, upon receipt of such a request, Proposer shall provide the District with such insurance policy within ten (10) days of receiving such request.
19.0 DATA AVAILABLE FROM ACWD The following data from ACWD is included in this RFP:
• Appendix A – Technical Proposal Submittal Form • Appendix B – Cost Proposal Submittal Form • Appendix C – Sample Agreement / Software-as-a-Service (SaaS) Requirements • Appendix D – AMI Business Drivers (bound herein) • Appendix E – Current Invoice Cloud and CSS System Architecture Diagram • Appendix F – Diagram of the Anticipated Interfaces with the Selected AMI System
ACWD JOB 10062 Water Focused Customer Portal RFP 44
Appendix A – Technical Proposal Submittal Form Request for Proposal Job 10062 CLOSING DEADLINE: 2:00 P.M. (local time) on October 31, 2019 Project Description: Water-Focused Customer Portal in Support of the Advanced Metering
Infrastructure (AMI) Project For: Alameda County Water District Submitted By: ___________________________________ (Company Name) ___________________________________ (Contact Name)
I/WE, THE UNDERSIGNED, HEREBY SUBMIT THIS PROPOSAL FOR THE PROVISION OF THE GOODS AND/OR SERVICES AS DESCRIBED WITHIN THE REQUEST FOR PROPOSAL DOCUMENT FOR THE ABOVE-NAMED PROJECT.
I/WE HAVE CAREFULLY EXAMINED THE DOCUMENTS AND HAVE A CLEAR AND COMPREHENSIVE KNOWLEDGE OF THE REQUIREMENTS AND HAVE SUBMITTED ALL RELEVANT DATA. I/WE AGREE, IF SELECTED, TO PROVIDE THOSE GOODS AND/OR SERVICES TO THE DISTRICT IN ACCORDANCE WITH THE TERMS, CONDITIONS AND SPECIFICATIONS CONTAINED IN THE PROPOSAL DOCUMENT AND OUR SUBMISSION.
PROPOSAL SUBMISSION
Proposal submission shall be irrevocable and open for acceptance for the Bid Acceptance Period, a period of 180 days following the date of the closing.
The Proposer submits that they have thoroughly reviewed this document together with the following Addenda and hereby accepts and agrees to all provisions and conditions stated herein and has included fully for all requirements in the Pricing:
Addendum No. _________ Dated: ________________________
Addendum No. _________ Dated: ________________________
Addendum No. _________ Dated: ________________________
Addendum No. _________ Dated: ________________________
ACWD JOB 10062 Water Focused Customer Portal RFP 45
LIST OF SUPPLIERS AND SUB-CONTRACTORS
The Proposer also agrees that the following is a complete list of suppliers and sub-contractors that will be required in the performance of the Work and that no additions, deletions or changes to this list will be permitted without the approval of the District.
Supplier and/or Subcontractor
Address Product/Service
CONFIRMATION OF MINIMUM REQUIREMENTS
Requirement Confirmation (yes or no)
A. Must be able to Integration to Cayenta CIS version 7.9.0.40
B. Must be able to use Invoice Cloud’s Single Sign-on Solution (e.g. Embedded IFrame, Redirects, Dialog Boxes). (i.e. customers will not need to re-register or change their password as part of implementation).
C. Real-time integration with Invoice Cloud and Cayenta
D. Real-time integration with the District’s selected AMI system.
TAX INFORMATION
Identification Number: _____________________________________________________
PRICING
The total price including all applicable taxes in legal currency of the United States must be included with your submission in order for your bid submission to be considered.
This Proposer’s Submission is made entirely in accordance with the Document. By your signature hereunder, it is deemed that you have read and agreed to all terms and conditions in the same manner as had such terms and conditions appeared above your signature, and that you have the authority to bind the Proposer.
ACWD JOB 10062 Water Focused Customer Portal RFP 46
COMPANY NAME AND ADDRESS:
TELEPHONE NUMBER: FAX NUMBER:
Dated at __________________ this ____ day of _____________, 2019.
Name/Title: Signature:
Witness: Signature:
ACWD JOB 10062 Water Focused Customer Portal RFP 47
Appendix B – Cost Proposal Submittal Form Request for Proposal Job 10062 CLOSING DEADLINE: 2:00 P.M. (local time) on October 31, 2019 Project Description: Water-Focused Customer Portal in Support of the Advanced Metering
Infrastructure (AMI) Project For: Alameda County Water District Submitted By: ___________________________________ (Company Name) ___________________________________ (Contact Name)
COMPANY NAME AND ADDRESS:
TELEPHONE NUMBER: FAX NUMBER:
COST PROPOSAL SUBMITTAL FORM
Proposers shall provide a Cost Proposal in accordance with Section 8 Compensation of the District’s Request for Proposal. Pricing can only be submitted broken into three sections: 1) Implementation Services Costs, 2) Software-as-a-Service (SaaS) Costs, and 3) Total Solution Cost. The Implementation Service will be delivered with a not-to-exceed cost ceiling.
Proposers may only provide pricing assumptions if they feel it provides additional clarity. Assumptions included with a Proposer’s Cost Proposal submission that alters the intended pricing description, may be ruled as informal. To avoid this circumstance, Proposers must provide any proposed deviations in writing to the District prior to the deadline for questions.
Pricing shall be submitted in U.S. dollars.
Dated at __________________ this ____ day of _____________, 20____.
Name/Title: Signature:
Witness: Signature:
ACWD JOB 10062 Water Focused Customer Portal RFP 48
Appendix C – Sample Agreement / Software-as-a-Service (Bound Herein)
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 1 of 16 10/07/2019
Agreement No. _________
CONTRACT FOR SOFTWARE AS A SERVICE (SaaS)
THIS AGREEMENT is made as of ___________________, 20__, by and between the ALAMEDA COUNTY WATER DISTRICT (“DISTRICT”) and _________________________ (“CONTRACTOR”), a ________________ corporation.
WHEREAS, the DISTRICT desires to obtain professional and software services for a Water-Focused Customer Portal in connection with the DISTRICT’s Advanced Metering Infrastructure (AMI) Project (“Project”), Job 10062, and has issued a Request for Proposals dated October 1, 2019, a copy of which is attached and incorporated as Exhibit A.
WHEREAS, the CONTRACTOR is ready, willing and able to furnish such services and has submitted a proposal dated___________________, a copy of which is attached and incorporated as Exhibit B.
NOW, THEREFORE, THE PARTIES AGREE AS FOLLOWS:
1. SCOPE OF SERVICES
The scope of the CONTRACTOR’s services shall consist of the services set forth in Exhibit A, as supplemented by Exhibit B. However, to the extent that Exhibit B is inconsistent with Exhibit A, Exhibit A will govern over Exhibit B.
2. SCHEDULE AND TIME OF COMPLETION
The term of this Agreement shall commence upon the date the DISTRICT issues the Notice to Proceed and shall terminate when the services described in Exhibit A, as supplemented by Exhibit B, have been satisfactorily completed, unless terminated sooner pursuant to Section 21. CONTRACTOR shall complete all tasks referenced in Section 2.0 of Exhibit A, as supplemented by Exhibit B.
3. CHANGES
The DISTRICT may, at any time, by written order, make changes within the scope of work and services described in this Agreement. If such changes cause an increase or decrease in the budgeted cost of or the time required for performance of the agreed upon work, an equitable adjustment as mutually agreed shall be made in the limit on compensation as set forth in Section 5 or in the time of required performance as set forth in Section 1 and 2, or both. In the event that CONTRACTOR encounters any unanticipated conditions or contingencies that may affect the scope of work or services and result in an adjustment in the amount of compensation specified herein, CONTRACTOR shall so advise the DISTRICT immediately upon notice of such condition or contingency. The written notice shall explain the circumstances giving rise to the unforeseen condition or contingency and shall set forth the proposed adjustment in compensation. This notice shall be given to the DISTRICT prior to the time that CONTRACTOR performs work or services related to the proposed adjustment in compensation. The pertinent changes shall be expressed in a written supplement to this Agreement prior to implementation of such changes.
4. INSURANCE
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 2 of 16 10/07/2019
A. Workers’ Compensation Insurance. CONTRACTOR shall maintain during the term of this Agreement Workers’ Compensation Insurance in conformance with the laws of the State of California, and federal laws when applicable.
B. Bodily Injury, Death and Property Damage Liability Insurance. CONTRACTOR shall maintain during the term of this Agreement Commercial General Liability Insurance (including automobile operation) covering CONTRACTOR for liability arising out of the operations of CONTRACTOR and any subcontractors. The policy(ies) shall include coverage for all vehicles, licensed or unlicensed, on or off DISTRICT’s premises, used by or on behalf of CONTRACTOR on the performance of work under this Agreement. The policy(ies) shall be subject to a limit for each occurrence of One Million Dollars ($1,000,000) naming as additional insureds, in connection with CONTRACTOR’s activities, the DISTRICT, ______________ and its or their board members, officers, employees, and agents. The policy(ies) will be primary insurance and the insurance companies providing the policy(ies) will be liable for the full amount of any loss or claim for which CONTRACTOR is liable up to and including the total limit of liability, without right of contribution from any other insurance effected or which may be effected by the DISTRICT.
C. Professional Liability Insurance. CONTRACTOR also shall maintain Professional Liability Insurance covering CONTRACTOR’s performance under this Agreement with a limit of liability of One Million Dollars ($1,000,000) for any one claim.
D. Network Security and Privacy Liability Insurance. Network Security and Privacy Liability insurance for the duration of this agreement providing coverage for, but not limited to, Technology and Internet Errors & Omissions, Security and Privacy Liability, and Electronic Media Liability. Insurance will cover claims that arise from the disclosure of private information from files but not limited to: 1) the errors or omissions of the CONTRACTOR, its employees or Sub-contractors and 2) penetration of the CONTRACTOR’s electronic data network, “firewall” or other security devices by hackers or others. The insurance policy should provide minimum coverage in the amount of $1,000,000 per occurrence and $2,000,000 annual aggregate. If written on a Claims-Made basis, the policy must provide an extended reporting period and have a retroactive date that on or before the date of this Contract or the date CONTRACTOR commences work, whichever is earlier.
E. Evidence of Insurance. Prior to the commencement of any work under this Agreement, CONTRACTOR shall furnish to DISTRICT a satisfactory Certificate of Insurance indicating compliance with the requirements of this section. The Certificate shall stipulate that thirty (30) days advance written notice of a cancellation or non-renewal of the required policy shall be given to DISTRICT.
F. General Insurance Conditions. All policies will be issued by insurers acceptable to the DISTRICT. The insurance will be issued by an insurance company authorized to do business in the State of California with a minimum “Best’s” rating of A- VII, or equivalent, or as otherwise approved by the DISTRICT. Workers’ Compensation coverage requirements may be met with the California State Compensation Fund.
In the event a claim is made, the DISTRICT reserves the right to request certified duplicate copies of all insurance policies required under this section.
5. COMPENSATION
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 3 of 16 10/07/2019
The CONTRACTOR agrees to perform all of the services included in this agreement for a total all-inclusive sum estimated not-to-exceed fee in accordance with Exhibits A and B. The total all-inclusive sum will include all labor, materials, taxes, profit, overhead, insurance, subcontractor/subconsultant costs, licensing, warranty, hosting, support, maintenance, transition requirements and all other costs and expenses incurred by the Consultant. The DISTRICT will pay the CONTRACTOR in accordance with Section 6.
6. MANNER OF PAYMENT
During the software development, testing and training phase (Implementation Services), the CONTRACTOR must submit invoices to the DISTRICT upon completion of the applicable milestone (deliverables based payments schedule), which will be set forth in a mutually agreeable milestone schedule and included herein as Exhibit B. The DISTRICT will retain a minimum of 15% of total Implementation Services compensation, which will be released upon issuance of the expiration of the 90-day Warranty Period, which will commence upon issuance of the Final Acceptance by the District. The DISTRICT will pay approved invoices for the Implementation Services within forty five (45) calendar days of their receipt.
Following the expiration of the 90-day Warranty Period the District will pay approved invoices for monthly SaaS Subscription Fees, based on based on the total activated accounts at the end of the completed month, minus any applicable Service Credit deductions as set forth in Section 9, within forty five (45) calendar days of their receipt.
Invoices must be submitted electronically via e-mail in PDF format with supporting documents/information, as appropriate to: [email protected] and any other staff email address the DISTRICT nominates as lead coordinator for this contract.
7. OWNERSHIP OF WORK
A. General
All reports, designs, drawings, plans, specifications, schedules, and other materials prepared, or in the process of being prepared for the services to be performed by CONTRACTOR will be and are the property of the DISTRICT. The DISTRICT will be entitled to copies and access to these materials during the progress of the work. Any such materials remaining in the hands of the CONTRACTOR or in the hands of any subcontractor upon completion or termination of the work will be immediately delivered to the DISTRICT. If any materials are lost, damaged, or destroyed before final delivery to the DISTRICT, the CONTRACTOR will replace them at its own expense and the CONTRACTOR assumes all risks of loss, damage, or destruction of or to such materials. The CONTRACTOR may retain a copy of all material produced under this Agreement for its use in its general business activities.
Any and all rights, title, and interest (including without limitation copyright and any other intellectual-property or proprietary right) to materials prepared under this Agreement are hereby assigned to the DISTRICT. The CONTRACTOR agrees to execute any additional documents that may be necessary to evidence such assignment.
The CONTRACTOR represents and warrants that all materials prepared under this Agreement are original or developed from materials in the public domain (or both) and that all materials prepared under and services provided under this Agreement do not infringe or
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 4 of 16 10/07/2019
violate any copyright, trademark, patent, trade secret, or other intellectual-property or proprietary right of any third party.
A. Intellectual Property Provisions
i. Definitions.
The term “Contractor Software” means any software reasonably necessary to operate or maintain any portions of the System that is a product or application of Contractor that pre-existed the execution of this Agreement.
The term “Contractor Software Customizations” means any software reasonably necessary to operate or maintain any portions of the System that is a customization, modification, or other change or addition of or to CONTRACTOR Software made under this Agreement.
The term “Third Party Software” means any software reasonably necessary to operate or maintain any portions of the System that does not constitute CONTRACTOR Software or CONTRACTOR Software Customizations.
The term “Materials” means any recorded information, whether or not copyrighted, that is delivered or specified to be delivered under the Agreement—with examples including, but not being limited to: computer software documentation; change logs; engineering drawings; specifications; standards; process sheets; manuals; technical reports; catalog item identifications; and related information—and for clarity, excluding financial, administrative, and cost and pricing information incidental to the work.
ii. Patent and Copyright Warranties. The CONTRACTOR represents and warrants that any use of the System (or any portion of the System) by DISTRICT (or its officers, directors, agents, employees, or transit users) will not infringe or violate the patent, copyright, trade-secret, or other intellectual-property or proprietary rights of any third party.
The CONTRACTOR further represents and warrants that it has or will have all appropriate licenses, agreements, or ownership rights pertaining to all patent, copyright, trade-secret, or other intellectual-property or proprietary rights needed for the performance of its obligations under this Agreement—including without limitation that it will have all necessary rights to use patentable or copyrightable materials, equipment, devices, or processes not furnished by the DISTRICT used on or incorporated in the work under this Agreement. The CONTRACTOR assumes all risks arising from the use of any such patented or copyrighted materials, equipment, devices, or processes.
In case any such software, materials, equipment, devices, processes, or other materials are held to constitute an infringement and their use enjoined, the CONTRACTOR, at CONTRACTOR’s sole cost and expense will: (a) secure for the DISTRICT the right to continue using the materials, equipment, devices or processes by suspension of the injunction or by procuring a royalty-free license, or licenses, or (b) replace such materials, equipment, devices, or processes with non-infringing materials, equipment, devices, or processes, or (c) modify them so that they become non-infringing or remove the enjoined materials, equipment, devices or processes and refund the sums paid for them without prejudice to any other rights of the DISTRICT. If the amount of time necessary to proceed with one of these options is deemed
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 5 of 16 10/07/2019
excessive by the DISTRICT, the DISTRICT may direct the CONTRACTOR to select another option or risk default.
iii. Source Code. The CONTRACTOR agrees that as a condition of final acceptance, it will deposit the source code for any CONTRACTOR Software and CONTRACTOR Software Customizations into escrow (including all updates, versions, releases, and upgrades licensed under this Agreement or any related maintenance agreements between CONTRACTOR and DISTRICT), with a source code agent capable of providing Level 2 certification/verification. Deposit will be at reasonable periodic intervals based generally on the pace at which the software is being developed or changed and will include any and all subsequent updates, versions, releases, and upgrades licensed under this Agreement or any related maintenance agreements between CONTRACTOR and DISTRICT. The source code escrow agreement will remain in place, and source code deposits will be updated and maintained, for as long as the District and CONTRACTOR have entered into a software maintenance or support agreement. The applicable source code will be released to the DISTRICT (or any CONTRACTOR acting on its behalf) in the event of CONTRACTOR’s nonperformance or the inability of CONTRACTOR to execute or maintain the portion of the System controlled by or through its applicable software. Such conditions of release include, but are not limited to (1) CONTRACTOR’s bankruptcy, (2) CONTRACTOR’s cessation of business, or (3) failure of CONTRACTOR to support, execute, maintain or provide enhancements in a timely manner to the portion of the System controlled by or through its applicable software. CONTRACTOR agrees that the DISTRICT (or any CONTRACTOR acting on its behalf) may use the source code to maintain, fix, or modify the CONTRACTOR Software and the CONTRACTOR Software Customizations as reasonably necessary to operate or maintain any portions of the System. CONTRACTOR and the DISTRICT will separately document an escrow agreement concurrently with this Agreement. The CONTRACTOR will be responsible for any costs related to the escrow.
iv. Patent Rights. If any invention, improvement, or discovery of CONTRACTOR is conceived or first actually reduced to practice in the course of or under this Agreement, which invention, improvement, or discovery may be patentable under the Patent Laws of the United States or any foreign country, CONTRACTOR will immediately notify DISTRICT and provide a detailed report. The rights and responsibilities of DISTRICT, CONTRACTOR and the federal government (if federally-funded) with respect to such invention will be determined in accordance with applicable federal laws, regulations, policies and any waivers thereof.
v. Non-Compete Clauses Waived. In the event that any of the release conditions set forth in any source code escrow agreement between the parties are satisfied and the source code is released to the DISTRICT, the DISTRICT will have the right to hire CONTRACTOR’s personnel or subcontractors for any reason related to the maintenance and operation of the System. The CONTRACTOR will not interfere with any such efforts to hire any of CONTRACTOR’s personnel. CONTRACTOR agreements with personnel and/or subcontractors that restrict employment by the DISTRICT will be waived under such circumstances.
vi. Precedence. In the event of any conflict between the provisions of this Section 7 and the provisions of any separate software license, escrow, or otherwise related agreement, this Section 7 will take precedence.
8. RESPONSIBILITY: INDEMNIFICATION
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 6 of 16 10/07/2019
The CONTRACTOR will indemnify, keep and save harmless the DISTRICT and its directors, officers, agents and employees (Indemnitees) against any and all suits, claims or actions arising out of any of the following:
A. Any injury to persons or property that may occur, or that may be alleged to have occurred, including over/under customer billing, arising from the performance of this Agreement by the CONTRACTOR caused by a negligent act or omission or willful misconduct of the CONTRACTOR or its employees, subcontractors or agents; or
B. Any allegation that materials or services provided by the CONTRACTOR under this Agreement infringe or violate any copyright, trademark, patent, trade secret, or any other intellectual-property or proprietary right of any third party; or
C. Any disclosure or allegation thereof of DISTRICT PII (defined below).
The CONTRACTOR further agrees to defend any and all such actions, suits or claims and pay all charges of attorneys and all other costs and expenses of defense as they are incurred. If any judgment is rendered against the Indemnitees in any such action, the CONTRACTOR will, at its expense, satisfy and discharge the same. This indemnification will survive termination or expiration of the Agreement.
9. SERVICE LEVEL AGREEMENT
The following additional requirements apply to the software solution:
Application Availability. CONTRACTOR must provide 99.9% application availability and maintain logs establishing uptime and downtime for the duration of the Contract.
Actual Application Availability % = (Monthly Minutes (MM) minus Total Minutes Not Available (TM)) multiplied by 100) and divided by Monthly Minutes (MM), but not including Excluded Events
Service Credit Calculation: An Outage will be deemed to commence when the Applications are unavailable to DISTRICT and end when CONTRACTOR has restored availability of the services. Failure to meet the 99.9% Application Availability, other than for reasons due to an Excluded Event, will entitle DISTRICT to a credit as follows:
Actual Application Availability % (as measured in a calendar month)
Service Credit to be applied to the District’s monthly invoice for the affected month
<99.99% to 99.9% 10% <99.9% to 99.75% 15% <99.75% to 98.75% 25% <98.75 to 97.75% 35% <97.75% 50%
“Outage” means the accumulated time, measured in minutes, during which DISTRICT is unable to make beneficial use of the Software or a portion thereof for reasons other than an Excluded Event.
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 7 of 16 10/07/2019
“Excluded Event” means any event that results in an Outage and is caused by (a) the acts or omissions of DISTRICT, its employees, customers, contractors or agents; (b) the failure or malfunction of equipment, applications or systems not owned or controlled by CONTRACTOR or its subcontractors; (c) Force Majeure events, excluding acts resulting in a breach of Confidential Information or Personally Identifiable Information; (d) scheduled or emergency maintenance, alteration or implementation provided during the Maintenance Period defined below; (e) any suspension of the services in accordance with the terms of the Contract; or (f) using an Application in a manner inconsistent with the product documentation for such Application.
“Maintenance Period” means scheduled maintenance periods mutually agreed upon by DISTRICT and CONTRACTOR to maintain and update the services, when necessary. During these Maintenance Periods, the Services are available to CONTRACTOR to perform periodic maintenance services, which include vital software updates. CONTRACTOR will use its commercially reasonable efforts during the Maintenance Period to make the services available to DISTRICT; however, some changes will require downtime. CONTRACTOR will provide notice for planned downtime via an email notice to the primary DISTRICT contact at least seven days in advance of any known downtime so planning can be facilitated by DISTRICT.
“Monthly Minutes (MM)” means the total time, measured in minutes, of a calendar month commencing at 12:00 am of the first day of such calendar month and ending at 11:59 pm of the last day of such calendar month.
“Total Minutes Not Available (TM)” means the total number of minutes during the calendar month that the services are unavailable as the result of an Outage.
10. TECHNICAL SUPPORT
Technical support will be available on a 24/7 basis. The CONTRACTOR may provide technical user support using a Follow the Sun model, unless otherwise prohibited in the services contract. The CONTRACTOR shall permit its personnel and subcontractors to access DISTRICT data remotely only as required to provide technical support.
11. REQUESTS FOR ACCESS TO DATA
The CONTRACTOR shall contact the DISTRICT upon receipt of any electronic discovery, litigation holds, discovery searches and expert testimonies related to the DISTRICT’s data or which in any way might reasonably require access to the data of the DISTRICT. The CONTRACTOR shall not respond to subpoenas, service of process and other legal requests related to the DISTRICT without first notifying the DISTRICT, unless prohibited by law from providing such notice.
12. DATA STORAGE AND LOCATION
The CONTRACTOR agrees to provide its services to the DISTRICT and its end users solely from data centers in the United States. Storage of DISTRICT data at rest shall remain in data centers located in the United States. The CONTRACTOR agrees to not allow its personnel or subcontractors store DISTRICT data on portable devices, including personal computers, except for devices that are used and kept only at its United States data centers.
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 8 of 16 10/07/2019
CONTRACTOR agrees to provide durable data storage that guarantees data availability for the duration of the storage term specified in Exhibit A, as supplemented by Exhibit B.
13. DATA PRIVACY
The CONTRACTOR may have access to personally identifiable information (PII) in connection with the performance of the Agreement. PII is any information that identifies or describes a person or can be directly linked to a specific individual, including water usage data and data access patterns. Examples of PII include, but are not limited to, name, address, phone or fax number, signature, date of birth, e-mail address, method of payment, payment card information, and water usage data. DISTRICT Personally Identifiable Information, or DISTRICT PII, means any PII relating to the DISTRICT’s customers.
The CONTRACTOR must ensure and maintain the confidentiality, security, safety, and integrity of all DISTRICT PII, including physical, electronic, and procedural safeguards designed to prevent unauthorized access or use and protect against known or anticipated threats to the security or integrity of such data. This includes, but is not limited to, the secure transport, transmission and storage of DISTRICT PII used or acquired in the performance of this Agreement. Notwithstanding the generality of the foregoing requirements, CONTRACTOR will adhere to the following requirements concerning DISTRICT PII:
A. The CONTRACTOR may not, except as authorized or required by law, reveal or divulge to any person or entity any DISTRICT PII that becomes known to it during the term of this Agreement. The CONTRACTOR may not use or attempt to use any such information in any manner that may injure or cause loss, either directly or indirectly, to the DISTRICT.
B. The CONTRACTOR must maintain policies and programs that prohibit unauthorized disclosure of DISTRICT PII and promote training and awareness of information security policies and practices. The CONTRACTOR must comply, and must cause its employees, representatives, agents, and subcontractors to comply, with such commercially and operationally reasonable directions as the DISTRICT may make to promote the safeguarding or confidentiality of DISTRICT PII.
C. The CONTRACTOR must conduct background checks for employees or Subcontractors that have access to DISTRICT PII or host DISTRICT PII.
D. The CONTRACTOR must limit access to computers and networks that host DISTRICT PII, including without limitation through user credentials and strong passwords, data encryption both during transmission and at rest, firewall rules, and network-based intrusion detection software.
E. The CONTRACTOR agrees to comply with the information handling and confidentiality requirements outlined in the California Information Practices Act (Civil Code sections 1798 et. seq.) and Civil Code Section 1798.81.5(b) by entering into this Agreement with the DISTRICT. In addition, the CONTRACTOR warrants and certifies that in the performance of this Agreement, it will comply with all applicable statutes, rules, regulations and orders of the United States, and the State of California relating to the handling and confidentiality of DISTRICT PII, including the terms and conditions contained in this Section.
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 9 of 16 10/07/2019
This Section will survive termination or expiration of this Agreement.
14. DATA OWNERSHIP
The DISTRICT will own all rights, titles and interest in its data that is related to the services provided by a SaaS contract. The CONTRACTOR shall not access DISTRICT user accounts or DISTRICT data, except (1) in the course of data center operations, (2) in response to service or technical issues, (3) as required by the express terms of the services contract, or (4) at the DISTRICT’s written request.
15. DATA SECURITY
The CONTRACTOR must provide those administrative, physical, and technical safeguards for protection of the security, confidentiality, integrity, and availability of DISTRICT PII pursuant to the minimum standards of care and critical security controls recommended by the California Attorney General in her February 2016 report (See https://oag.ca.gov/breachreport2016). The CONTRACTOR shall provide security for its networks and systems consistent with accepted industry practices (including, as periodically amended or updated, the ISO/IEC 27001 series Information Security Management Systems standards, NIST Special Publication 800-53 Security and Privacy Controls, the Information Technology Infrastructure Library (ITIL) standards, the Control Objectives for Information and related Technology (COBIT) standards or other applicable industry standards for information security observed by well-managed solutions that store PII, and will promptly install all patches, fixes, upgrades, updates, and new versions of any security software it employs.
The CONTRACTOR will maintain appropriate safeguards to restrict access to DISTRICT’s Data to those employees, contractors, agents, or service providers of the CONTRACTOR who need the information to carry out the purposes for which it was disclosed to CONTRACTOR. For information disclosed in electronic form, appropriate safeguards include electronic barriers (e.g. firewalls, Transport Layer Security (TLS) or most current industry standard encryption, intrusion prevention/detection or similar barriers) and secure authenticated (e.g. password protected) access to the DISTRICT’s Confidential Information and DISTRICT Data.
Protection of PII and confidential data shall be an integral part of the business activities of the CONTRACTOR to ensure there is no inappropriate or unauthorized use of DISTRICT information at any time. To this end, the CONTRACTOR shall safeguard the confidentiality, integrity and availability of DISTRICT information and comply with the following conditions:
A. The CONTRACTOR agrees to properly secure and maintain any computer, hardware and software applications, or electronic media that it will use in the performance of this Agreement. This includes ensuring all security patches, upgrades, and anti-virus updates are applied to secure DISTRICT PII that may be used, transmitted, or stored on such software in the performance of this Agreement.
B. The CONTRACTOR, its employees, agents, subcontractors, and contractors may not download or otherwise store any DISTRICT PII onto any CONTRACTOR computer, desktop, laptop, thumb drives, disks, or other portable memory device without such data being encrypted.
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 10 of 16 10/07/2019
C. All personal data shall be encrypted at rest and in transit with controlled access. Unless otherwise stipulated, the CONTRACTOR is responsible for encryption of the DISTRICT PII data.
D. Unless otherwise stipulated, the CONTRACTOR shall encrypt all non-public data at rest and in transit.
E. At no time shall any data or processes – that either belong to or are intended for the use of a DISTRICT or its officers, agents or employees – be copied, disclosed or retained by the CONTRACTOR or any party providing service to the CONTRACTOR for subsequent use in any transaction that does not include the DISTRICT.
F. The CONTRACTOR represents that its hosting environment is built upon a secure infrastructure, which undergoes examinations from an independent auditor in accordance with the minimum standards of care and critical security controls recommended by the California Attorney General in her February 2016 report (see above). For added security, the CONTRACTOR will use multi-factor authentication when accessing the infrastructure. In addition to the independent audit, DISTRICT will have the right at any time, upon reasonable notice, to audit and inspect: (i) CONTRACTOR’s facilities where the DISTRICT PII is stored or maintained; (ii) any computerized software used to share, disseminate or otherwise exchange DISTRICT PII; and (iii) CONTRACTOR’s security practices and procedures, data protection, business continuity and recovery facilities, resources, plans and procedures related to software where the DISTRICT PII is shared, disseminated or otherwise exchanged. The audit and inspection rights hereunder will be for the purpose of verifying CONTRACTOR’s compliance with this Agreement, and all applicable laws.
G. The CONTRACTOR must process and store all DISTRICT PII in a single-tenant environment and at no time will DISTRICT PII be commingled with data of independent third-party users of CONTRACTOR’s services.
H. The CONTRACTOR must have vulnerability management programs to identify and minimize threats and risks on any software used to store or transmit DISTRICT PII.
I. The CONTRACTOR represents that the CONTRACTOR’s management access to the hosting infrastructure is limited to authorized support staff. The security architecture has been designed to control appropriate logical access to the infrastructure to meet industry standards that meet or exceed the Trust Services Criteria and Principles for Security, Availability, Integrity, and Confidentiality established by the AICPA.
J. Notwithstanding anything to the contrary in this Agreement, the CONTRACTOR agrees to retain DISTRICT PII for ninety (90) days after the completion date of this Agreement and the DISTRICT’s confirmation that the CONTRACTOR may proceed with such deletion. At the conclusion of this retention period, the CONTRACTOR agrees to use U.S. Department of Defense (“DoD”) –approved method and removal of DISTRICT PII from any files, with said service being included in the total cost of this Agreement. Discarded DISTRICT PII will be unavailable and unrecoverable following the purge on any storage media including, but not limited to, magnetic disk, optical disk, and memory chips (“Storage Media”). The CONTRACTOR agrees to destroy hard-copy documents containing DISTRICT PII by means of a cross-cut shredding machine. The CONTRACTOR also agrees to use DoD—approved methods, or an alternate DISTRICT-approved method, to sanitize any Storage Media prior to discarding or when useful life has ended, whichever comes first. At the conclusion of the
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 11 of 16 10/07/2019
performance period of this Agreement, the CONTRACTOR will submit a certification to the DISTRICT that all electronic or hard-copy format DISTRICT PII has been destroyed in accordance with the Agreement.
This Section will survive termination or expiration of this Agreement.
16. NOTICE OF SECURITY BREACH
The CONTRACTOR must immediately notify the DISTRICT when it discovers that there may have been a data security incident that has or may have resulted in compromise to DISTRICT PII. For purposes of this Section, immediately is defined as within twenty-four hours of discovery. The CONTRACTOR must immediately take such actions as may be necessary to preserve forensic evidence and eliminate the cause of any suspected breach or security vulnerability—and must promptly alert the DISTRICT of any such circumstances, including information sufficient for the DISTRICT to assess the nature and scope of any suspected data breach. In the event of an unauthorized disclosure of DISTRICT PII, the CONTRACTOR will be liable for paying for the following costs to remediate any such unauthorized disclosure:
A. The reasonable cost of providing notice of the breach to individuals affected by such breach;
B. The reasonable cost of providing required notice of the breach to government agencies, credit bureaus, and/or other required entities;
C. The cost of providing individuals affected by such breach with credit protection services designed to prevent fraud associated with identity theft crimes for a specific period not to exceed 12 months; and
D. Any other service required by applicable law.
The CONTRACTOR must provide any information and/or support to the DISTRICT in issuing the actual notification and, at the DISTRICT’s sole discretion, the CONTRACTOR must itself provide actual notification if the DISTRICT desires. This Section will survive termination or expiration of this Agreement.
17. CONTRACTOR’S STATUS
Neither the CONTRACTOR nor any party contracting with the CONTRACTOR shall be deemed to be an agent or employee of the DISTRICT.
CONTRACTOR is and shall be an independent CONTRACTOR, and the legal relationship of any person performing services for the CONTRACTOR shall be one solely between that person and the CONTRACTOR.
18. ASSIGNMENT
CONTRACTOR shall not assign any of its rights nor transfer any of its obligations under this Agreement without the prior written consent of DISTRICT.
19. DISTRICT WARRANTIES
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 12 of 16 10/07/2019
The DISTRICT makes no warranties, representations or agreements, either expressed or implied, beyond such as are explicitly stated in this Agreement.
20. DISTRICT REPRESENTATIVE
Except when approval or other action is required to be given or taken by the Board of Directors of the DISTRICT, the General Manager of the DISTRICT, or such person or persons as the General Manager shall designate in writing from time to time, the Project Manager shall represent and act for the DISTRICT.
21. TERMINATION
The DISTRICT shall have the right to terminate this Agreement at any time by giving written notice to the CONTRACTOR. Upon receipt of such notice, the CONTRACTOR shall not commit itself to any further expenditure of time or resources.
If the Agreement is terminated for any reason other than a default by CONTRACTOR, the DISTRICT shall pay to CONTRACTOR in accordance with the provisions of Sections 5 and 6 all previously approved sums from DISTRICT. If the Agreement is terminated for default, the DISTRICT shall remit final payment to CONTRACTOR in an amount to cover only those services performed and expenses incurred in full accordance with the terms and conditions of this Agreement up to the effective date of termination. Final payment shall be remitted after the DISTRICT receives all owned data hosted by the CONTRACTOR.
22. MAINTENANCE, AUDIT, AND INSPECTION OF RECORDS
The CONTRACTOR shall permit the authorized representatives of the DISTRICT to inspect, audit, make copies and transcriptions of books and all data and records of the CONTRACTOR relating to its performance under the Agreement.
23. RELEASE OF INFORMATION
CONTRACTOR shall not release any reports or other information prepared in connection with this Agreement without the approval of the General Manager/Approver. Non-Disclosure requirements are identified in Exhibit C.
24. KEY PERSONNEL
_________________ shall serve as the primary staff person of CONTRACTOR to oversee all of the services under this Agreement.
25. NOTICES
All communications relating to the day to day activities of the project shall be exchanged between the DISTRICT’s Project Manager and the CONTRACTOR’s Project Manager.
All other notices and communications deemed by either party to be necessary or desirable to be given to the other party shall be in writing and may be given by personal delivery to a representative of the parties or by mailing the same postage prepaid, addressed as follows:
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 13 of 16 10/07/2019
If to the DISTRICT:
Alameda County Water District
43885 South Grimmer Boulevard
PO Box 5110
Fremont, CA 94537-5110
Attention: Ben Egger, Project Engineer
If to the CONTRACTOR: Company Name
Address
City, State, Zip Code
Attention: _____________________, Title
The address to which mailings may be made may be changed from time to time by notice mailed as described above. Any notice given by mail shall be deemed given on the day after that on which it is deposited in the United States Mail as provided above.
26. ATTORNEYS’ FEES
If any legal proceeding should be instituted by either of the parties to enforce the terms of this Agreement or to determine the rights of the parties under this Agreement, the prevailing party in said proceeding shall recover, in addition to all court costs, reasonable attorneys’ fees.
27. APPLICABLE LAW
This Agreement, its interpretation, and all work performed under it shall be governed by the laws of the State of California.
28. BINDING ON SUCCESSORS
All of the terms, provisions, and conditions of this Agreement shall be binding upon and inure to the benefit of the parties and their respective successors, assigns, and legal representatives.
29. SEVERABILITY
Should any provision, or portion of a provision, herein be found or deemed to be invalid, this Agreement shall be construed as not containing such provision, or portion of such provision, and all other provisions which are otherwise lawful shall remain in full force and effect, and to this end the provisions of this Agreement are declared to be severable.
30. BINDING ON SUCCESSORS
All of the terms, provisions, and conditions of this Agreement shall be binding upon and inure to the benefit of the parties and their respective successors, assigns, and legal representatives.
31. TRANSITION
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 14 of 16 10/07/2019
Upon the termination or expiration of this Agreement, the CONTRACTOR must cooperate fully with the DISTRICT, and any successor CONTRACTOR to provide to the DISTRICT, and any successor CONTRACTOR, electronic copies of all branding materials, logos, reports, designs, drawings, plans, specifications, schedules, information, payment history, payment records, and other materials prepared, or in the process of being prepared for the services to be performed by CONTRACTOR (Work Product) to ensure a smooth transition to a new software solution. All DISTRICT PII must be protected, kept secure, and transmitted securely at all times in accordance with the terms of this Agreement. All Work Product must be provided in a format that is usable by the successor CONTRACTOR, such as latest version of Microsoft WORD and/or EXCEL.
If the DISTRICT terminates the Agreement, the CONTRACTOR must begin preparing all Work Product to allow for a smooth transition to a successor CONTRACTOR or to permit the DISTRICT to operate a similar software solution in the future. Within 30 calendar days of the DISTRICT’s termination of the Agreement, the CONTRACTOR must transfer all other Work Product, including written reports, data, and other relevant information, to the DISTRICT and the successor CONTRACTOR. The DISTRICT will withhold payment of CONTRACTOR’s final invoice until CONTRACTOR has ensured a smooth transition to the successor CONTRACTOR or transmitted all required documents for the DISTRICT’s records, as determined by the DISTRICT in its sole discretion.
Upon expiration of this Agreement, CONTRACTOR must transfer all other Work Product, including written reports, data, and other relevant information, to the DISTRICT and the successor CONTRACTOR (if applicable). The DISTRICT will withhold payment of CONTRACTOR’s final invoice until CONTRACTOR has ensured a smooth transition to the successor CONTRACTOR or transmitted all required documents for the DISTRICT’s records, as determined by the DISTRICT in its sole discretion.
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 15 of 16 10/07/2019
IN WITNESS WHEREOF, the parties hereto have executed this Agreement by
their duly authorized officers as of the day and year first above written.
CONTRACTOR: FILL IN CONTRACTOR'S NAME HERE
DISTRICT: ALAMEDA COUNTY WATER DISTRICT
By: President or Vice President
By: General Manager
Name: Name: Robert Shaver
By: Secretary or Assistant Secretary
ATTEST:
Name: By: District Secretary
ACWD SaaS Agreement 10/2019 10062 – AMI Deployment Project
Page 16 of 16 10/07/2019
EXHIBIT A - REQUEST FOR PROPOSALS FOR AMI DEPLOYMENT
EXHIBIT B - PROPOSAL
EXHIBIT C - NON-DISCLOSURE FORM (S)
ACWD JOB 10062 Water Focused Customer Portal RFP 49
Appendix D – AMI Business Drivers (Bound Herein)
ALA
ME
DA
CO
UN
TY
WA
TE
R D
IST
RIC
T
1
Esse
ntia
l – A
MI B
usi
ness
drive
rs t
hat
score
d a
3 (
defined
as v
ery
im
port
ant: T
he D
istr
ict w
ill im
ple
ment th
e b
usi
ness
drive
r im
media
tely
an
d it
is
critic
al t
o th
e p
roje
ct).
Impo
rtant – A
MI B
usi
ne
ss d
rive
rs the
score
d a
2 (
defined a
s im
port
ant: T
he
Dis
tric
t w
ou
ld im
ple
ment th
e b
usin
ess
drive
r im
me
dia
tely
).
Ref
Imp
ort
an
ce
Bu
sin
ess
Dri
ve
rs &
De
sc
rip
tio
n
AC
WD
Re
ven
ue P
rote
cti
on
(R
P)
RP
2
3T
am
per
Dete
cti
on
/ Z
ero
Co
nsu
mp
tio
n
AM
I te
chn
olo
gy
allo
ws
a u
tilit
y to
dete
ct p
ote
ntial ta
mpering in
a n
um
ber
of w
ays
:
·
Ab
no
rmal c
on
sum
ptio
n: b
y w
ay
of
de
tectin
g c
onsu
mptio
n (
or
a r
ed
uct
ion
in c
onsum
ptio
n)
in a
ccou
nts
wh
ere
AC
WD
would
be e
xpe
ctin
g th
e o
pp
osite
beh
avio
r. S
om
e e
xam
ple
s o
f
this
occurr
ing:
o
Com
merc
ial p
rop
ert
y (la
un
dry
) th
at re
quir
es w
ate
r to
opera
te s
ud
den
ly h
as
zero
consum
ptio
n d
uri
ng
pe
ak tim
es.
o
Pro
pert
y is
va
cant
and
sh
ould
be t
urn
ed
off
, b
ut sudd
enly
show
s c
onsum
ptio
n.
o
Com
merc
ial p
rop
ert
y tu
rnin
g o
n th
eir b
ypa
ss r
ed
ucin
g c
onsum
ptio
n o
n th
e m
ete
r.
o
Dete
ctor
check m
ete
rs s
how
ing
con
sum
ptio
n (
non
e w
as e
xpect
ed
).
·
Mete
r re
mo
ved
tam
per
(man
ufa
cture
r spe
cific
) – w
here
by
a c
usto
me
r re
move
s th
e r
eg
iste
r
or
the m
ete
r, a
nd th
e r
eg
iste
r d
ete
cts t
he p
hys
ical m
ovem
en
t. T
his
would
have t
o b
e r
ese
t
by
the c
usto
me
r.
·
Em
pty
pip
e a
larm
– there
is n
o w
ate
r in
th
e m
ete
r a
nd a
n a
larm
is s
ent.
AC
WD
wate
r m
ete
rs a
re in
sta
lled in m
ete
r pits
at th
e p
rop
ert
y lin
e; th
is m
akes it
more
diffic
ult fo
r a
cust
om
er
to tam
pe
r w
ith a
mete
r. A
rea
s w
here
AC
WD
could
use
this
fun
ctio
nalit
y:
1.
So
ft S
hut O
ff M
onitori
ng:
curr
en
tly A
CW
D p
erf
orm
s check r
ea
ds fo
r M
OV
EIN
, M
OV
EO
UT
sce
na
rios.
Ea
ch r
eq
uire
s a tru
ck
roll
to c
olle
ct th
e r
ead
ing o
n a
sp
ecifi
c d
ay.
Alte
rnativ
ely
, fin
al a
nd
initi
al r
eads
can b
e o
bta
ine
d t
hro
ugh t
he n
etw
ork
and p
laced
in a
“vi
rtua
l sh
ut
off
” gro
up t
hat
will
ale
rt A
CW
D if consum
ptio
n o
ccu
rs p
rior
to a
move
in r
eque
st.
2.
Com
merc
ial M
ete
r M
onitorin
g:
AC
WD
can m
onitor
cust
om
ers
who
are
kn
ow
n to h
ave
ope
rate
d
their b
ypass
valv
e w
ithou
t a
uth
oriza
tion
.
RP
3
3
Dete
ct
Mis
ap
plied
Mete
rs
Typ
e 1
: C
om
poun
d m
ete
rs,
une
ven w
ear:
results
in e
ithe
r th
e h
igh o
r lo
w s
ide o
f th
e m
ete
r to
we
ar
ou
t a
nd r
eco
rd m
uch
less a
ccu
rate
ly.
Add
ing m
ore
gra
nula
r data
(do
wn to
the
ho
ur
consum
ption
pe
rio
ds)
will
he
lp b
ett
er
und
ers
tan
d w
ate
r consum
ptio
n u
sage,
in c
om
parison
to e
very
30 d
ays
.
Typ
e 2
: C
om
poun
d m
ete
rs,
cro
ss o
ver:
ide
ntif
y th
ose m
ete
rs w
he
re a
sig
nifi
cant a
moun
t of
a
cust
om
er
wate
r d
em
an
d f
low
ra
te a
roun
d th
e c
ross
ove
rflo
w r
ate
with low
er
mete
r accu
racy.
Ho
url
y
consum
ption a
naly
sis
can
de
tect th
is.
Typ
e 3
: L
ow
flo
w o
n turb
ine m
ete
rs: m
ete
rs t
hat
have a
sig
nifi
cant
am
oun
t of
a c
ust
om
er’s w
ate
r
de
ma
nd
flo
w r
ate
is lo
wer
than
the
mete
r in
pla
ce.
Curr
ently,
custo
me
rs a
re n
ot
charg
ed f
or
wate
r u
ntil
the m
ete
r is
repla
ced.
The
re is
no e
stim
atio
n w
hen a
mete
r be
com
es
faulty.
The
mete
r sh
op c
ould
use th
ese f
eatu
res to
iden
tify
com
merc
ial m
ete
rs th
at re
qu
ire
main
tena
nce.
Th
is w
ould
en
han
ce A
CW
D’s
cu
rrent
pro
act
ive
wate
r m
ete
r m
ain
ten
ance p
rog
ram
.
RP
4
2R
ed
uce
us
ag
e
on
ac
co
un
ts t
hat
sh
ou
ld b
e z
ero
Ze
ro c
onsum
ptio
n: id
en
tifyi
ng t
hose p
rop
ert
ies w
he
re th
e u
tility
is e
xpectin
g z
ero
co
nsu
mptio
n
when
co
nsu
mp
tion
occu
rs t
he u
tilit
y sho
uld
be n
otif
ied. S
om
e e
xam
ple
s o
f th
is o
ccurr
ing:
·
De
tecto
r che
ck m
on
itori
ng
: de
tectin
g a
ny
consum
ption
th
at o
ccurs
on
de
tecto
r che
ck
me
ters
an
d m
on
itori
ng t
he
am
ou
nt o
f w
ate
r, e
nsurin
g the
wa
ter
de
ma
nd f
low
rate
is n
ot
goin
g t
hro
ug
h th
e u
n-m
ete
red p
ort
ion
of
the
de
tecto
r ch
eck
.
·
No
n-p
aym
ent:
whe
re a
mete
r is
tu
rne
d o
ff a
nd t
he
re s
ho
uld
be
no c
onsum
ption a
t th
e
pro
pert
y.
AC
WD
wou
ld b
enefit fr
om
monito
ring t
hese c
usto
me
rs t
hro
ugh
a v
irtu
al sh
ut
off
gro
up.
·
Dete
ctor
che
ck m
ete
rs m
onito
rin
g: A
CW
D h
as
app
roxim
ate
ly 2
,250 d
ete
cto
r che
ck m
ete
rs. T
he
re
are
inst
ances w
he
re c
usto
me
rs s
ho
we
d c
on
sum
ptio
n w
here
the
re s
ho
uld
ha
ve b
een n
on
e. It
is
likely
tha
t a
nu
mber
of
cu
stom
ers
are
gettin
g a
sig
nific
ant
am
oun
t o
f un
-mete
red w
ate
r th
rough
th
e
fire
line
. A
MI te
chno
log
y co
uld
monitor
these t
ypes o
f eve
nts
.
·
Non
-pa
ymen
t m
onitori
ng
: T
hese
acc
oun
ts c
ould
als
o b
e p
ut
into
a “
virt
ua
l sh
ut o
ff”
gro
up t
hat
ale
rts
AC
WD
if c
on
sum
ptio
n o
ccurs
pri
or
to p
aym
ent b
ein
g r
ece
ive
d.
RP
6
3
Be
tter
Data
for
Futu
re R
ate
Deve
lop
me
nt
Hourl
y co
nsu
mptio
n d
ata
allo
ws
a w
ate
r utilit
y to
bett
er
und
ers
tand
who
an
d w
he
n w
ate
r is
be
ing
consum
ed
. H
avin
g a
ctu
al consu
mptio
n d
ata
inst
ead
of
an
estim
ate
acr
oss
the
month
ly o
r bi-
month
ly b
ill p
eri
od
(th
at m
an
ua
l rea
d m
ete
rs p
rovi
de)
can m
ake r
ate
stu
die
s m
ore
eff
icie
nt a
nd
more
accura
te. W
hen a
utilit
y has w
ate
r capa
city
or
dro
ught
cond
itio
ns a
utilit
y can
de
velo
p
seasona
l rate
s o
r fines th
at
will
be t
arg
ete
d a
t a c
ert
ain
seg
me
nt o
f th
e c
usto
mers
(to
p w
ate
r
users
).
AC
WD
re
vie
ws
its w
ate
r ra
tes a
bo
ut e
very
fiv
e y
ea
rs a
nd
in th
e p
ast
ha
s im
ple
mente
d d
roug
ht ra
tes f
or
cust
om
ers
exce
edin
g a
daily
ave
rag
e c
on
sum
ptio
n (
ba
sed o
n a
bi-
month
ly a
vera
ge
). A
MI da
ta w
ill h
elp
AC
WD
in th
e fu
ture
th
rou
gh:
·
Definin
g t
rue
maxim
um
da
ily c
onsum
ption
restr
ictio
ns
·
Pro
vid
e m
ore
gra
nu
lar
da
ta f
or
rate
sett
ing a
naly
sis
·
Pro
vid
e f
eed
ba
ck o
n r
ate
cha
ng
e e
ffectiv
en
ess
ALA
ME
DA
CO
UN
TY
WA
TE
R D
IST
RIC
T
2
Ref
Imp
ort
an
ce
Bu
sin
ess
Dri
ve
rs &
De
sc
rip
tio
n
AC
WD
Op
era
tio
nal E
ffic
ien
cy (
OE
)
OE
1
3
Imp
rove M
ete
r
Re
ad
ing
Safe
ty
& R
elia
bilit
y
AM
I te
chn
olo
gy
will
elim
inate
liab
ility
ass
ocia
ted w
ith e
mplo
yees in
th
e fie
ld. It
is im
port
an
t to
hig
hlig
ht
tha
t im
pro
vin
g m
ete
r re
adin
g s
afe
ty a
nd r
elia
bili
ty m
ay
not d
rive f
unctio
na
lity
but
is s
till
a
bu
sin
ess
driver
tha
t su
pp
ort
s th
e D
istr
ict’s
cultu
re o
f safe
ty initia
tives.
Me
ter
read
ers
are
in a
ve
ry h
igh-r
isk
gro
up f
or
inju
ries d
ue t
o t
he p
hys
ica
l natu
re o
f th
e w
ork
and
th
e w
ide
are
a in
whic
h th
ey
pe
rform
th
e w
ork
. A
MI te
chno
log
y w
ould
elim
inate
mete
r re
ad
ers
fro
m t
he
fie
ld w
hic
h
will
low
er
the lost tim
e in
jury
costs
an
d p
ote
ntia
lly in
sura
nce p
rem
ium
s.
OE
2
3R
ed
uc
e B
illi
ng
Exce
pti
on
s
Elim
ina
te s
om
e h
igh
/low
bill
ing
exce
ptions. C
onsum
ptio
n A
lert
s: sett
ing u
p a
lert
s a
cross
custo
mer
gro
ups (
typic
ally
by
mete
r siz
e o
r cu
stom
er
type)
wou
ld p
rovid
e c
usto
me
rs w
ith th
e c
ha
nce to
chang
e the
ir c
onsum
ptio
n b
eha
vior
pri
or
to r
ece
ivin
g a
hig
h-w
ate
r b
ill. E
xam
ple
s o
f ale
rts tha
t can
red
uce b
ill e
xce
ptions:
·
Hig
h C
onsum
ptio
n A
lert
: 5 d
ays
of
consum
ption t
hat
is g
reate
r th
an 3
00
% d
aily
avera
ge
con
sum
ptio
n tri
gge
rs c
om
mun
icatio
n t
o th
e c
usto
mer.
·
Co
ntinuo
us c
onsum
ption a
lert
: U
tilit
ies
spe
cifie
d n
um
ber
of d
ays
of
contin
uous h
ou
rly
con
sum
ptio
n w
ith a
min
imu
m o
f X
cub
ic fe
et.
·
These a
lert
s w
ill p
ush c
om
mu
nic
atio
n t
o th
e c
usto
mer
well
be
fore
th
e b
ill is p
rodu
ced.
Curr
ently,
AC
WD
has
num
ero
us h
igh/low
exc
eption
s th
at ne
ed
to b
e in
vestig
ate
d a
nd
resolv
ed d
aily
.
Th
ese a
lert
s w
ill n
ot
elim
inate
th
is b
illin
g e
xce
ption p
rocess; ho
we
ver,
th
ey
shou
ld r
edu
ce the
fre
que
ncy
an
d p
rovi
de
cu
stom
ers
with
the
ab
ility
to c
ha
ng
e th
eir
consum
ption b
eh
avio
r pri
or
to r
ece
ivin
g a
bill
.
OE
3
3D
ete
ct
Reg
iste
r
an
d C
ut
Wir
ing
Pro
ble
ms
Radio
tra
nsm
itters
are
co
nne
cted t
o a
wate
r m
ete
r re
gis
ter
thro
ugh a
3-c
ondu
ctor
wir
e. A
sm
all
pe
rce
nta
ge o
f m
ete
rs m
ay
requ
ire
main
tena
nce t
o r
epair
or
rep
lace t
he w
ire a
nd
/or
regis
ter.
An
AM
I sys
tem
will
de
tect
and
ale
rt t
he m
ete
r sho
p w
hen
main
ten
ance is
requ
ired
. T
he g
oa
l w
ou
ld b
e
to r
espon
d t
o r
ead
ing is
sues p
rior
to t
he is
sue a
ffe
ctin
g c
ust
om
er
bill
s.
AC
WD
wate
r m
ete
r p
opu
lation
is c
urr
en
tly
rea
d m
an
ua
lly b
y a
mete
r re
ader
wh
o r
eco
rds th
e r
ead
ing in
to a
ha
ndh
eld
. In
tro
ductio
n o
f a
n A
MI o
r A
MR
sys
tem
will
ad
d th
ree c
om
ponents
(w
ire, e
ncod
er
regis
ter,
ra
dio
tran
smitte
r) t
o th
e w
ate
r m
ete
r sys
tem
that A
CW
D w
ill n
eed
to
ma
inta
in,
wh
ile r
em
ovin
g a
gin
g m
an
ual
mete
r re
adin
g e
quip
men
t.
OE
4
3R
ed
uc
e R
eg
ula
r
Me
ter
Rea
din
g
Co
st
Redu
ce r
egu
lar
me
ter
readin
g c
ost
s.
Imple
mentin
g A
MI
acro
ss
the e
ntire
wate
r m
ete
r pop
ula
tion w
ill e
limin
ate
the n
ee
d f
or
mete
r re
aders
to
colle
ct the
bill
able
re
adin
g.
Th
e r
educed
nu
mb
er
of
truck
ro
lls w
ill c
ut do
wn
on
th
e D
istr
ict’s
carb
on e
mis
sions, h
elp
ing
meet
the g
oals
of
our
Cle
an E
nerg
y In
itia
tive
an
d g
ree
nho
use m
an
date
s fro
m the S
tate
of
Ca
liforn
ia.
OE
5
3
Sam
e D
ay
Fin
al
an
d S
pe
cia
l
Re
ad
s
AM
I te
chn
olo
gy
allo
ws
for
readin
g d
uri
ng o
ff c
ycle
s e
limin
atin
g th
e n
ee
d to
send
ou
t a
mete
r
rea
der.
AM
I an
d M
DM
techn
olo
gy
will
allo
w f
or
cust
om
ers
to b
e c
lassi
fied into
gro
up
s; in t
his
case
a z
ero
-consum
ptio
n g
rou
p w
hic
h c
an
ale
rt t
he U
tilit
y w
hen
co
nsum
ption
occu
rs a
t th
e p
rop
ert
y pri
or
to th
e n
ew
custo
mer
sett
ing
up
a n
ew
wa
ter
acc
ou
nt.
On a
vera
ge
AC
WD
has o
ver
10,0
00 “
Mo
ve O
ut”
(M
VO
UT
) and
ap
pro
xim
ate
ly 5
,000
“M
ove
In”
(MV
IN)
pe
r
year.
T
oda
y, e
ach
respo
nse r
equ
ires
a t
ruck
roll
to t
urn
th
e w
ate
r o
ff /
on.
An A
MI
sys
tem
will
allo
w A
CW
D
to p
erf
orm
th
ese fu
nctio
ns
rem
ote
ly b
y obta
inin
g th
e o
ff o
r on
rea
d a
nd p
lacin
g th
e m
ete
r in
a “
virt
ua
l turn
off
” conditi
on.
An a
lert
is is
sued t
o A
CW
D w
he
n t
he p
rop
ert
y be
com
es o
ccup
ied
initi
ating
a c
all
to th
e
cust
om
er
or
trig
ge
ring
a f
ield
vis
it.
Curr
ently
there
are
tw
o m
ete
r re
ad
ers
de
dic
ate
d to t
hese s
pecia
l rea
ds
an
d in
vest
iga
tions. A
MI T
ech
no
log
y w
ill m
inim
ize
th
e n
eed
for
these f
ield
vis
its.
Imp
rove
d S
ys
tem
Dis
trib
uti
on
(D
S)
DS
1.5
2
P
ressu
re z
on
e
mo
nit
ori
ng
Mo
nitori
ng t
he p
ressure
in v
ari
ou
s p
art
s of
the s
yste
m c
ou
ld h
elp
opera
tors
bett
er
man
ag
e/
op
timiz
e w
he
n p
um
pin
g s
hould
occur,
ta
nk
leve
ls a
nd p
ote
ntially
identify
are
as w
he
re la
rge
red
uctio
n in
pre
ssure
co
uld
poin
t to
eith
er
larg
e w
ate
r d
em
and
or
wa
ter
ma
in b
rea
k.
AC
WD
has a
10 p
ressu
re z
on
es, w
ith z
one
1 b
ein
g the
larg
est serv
ing t
he m
ajo
rity
of
AC
WD
cust
om
ers
.
Som
e o
f th
e s
mall
pre
ssure
zo
nes (
with lim
ited s
tora
ge
capaci
ty o
r cost
ly s
ourc
e p
um
pin
g c
ost
s d
ue to
altitu
de)
would
lik
ely
bene
fit f
rom
additi
ona
l pre
ssure
monitori
ng.
DS
2
3
Dy
nam
ic W
ate
r
Ba
lan
ce
Wate
r u
tilitie
s are
ma
nd
ate
d to p
erf
orm
an a
nnu
al w
ate
r bala
nce (
AW
WA
Wate
r A
ud
it S
oft
wa
re)
to c
alc
ula
te n
on
-revenu
e w
ate
r a
cro
ss th
eir s
yste
m p
er
SB
-55
5. W
ith h
ourl
y A
MI con
sum
ptio
n
da
ta f
or
all
custo
me
rs,
this
typ
e o
f w
ate
r ba
lan
ce c
ould
be p
erf
orm
ed b
oth
more
acc
ura
tely
and
on
a m
ore
fre
que
nt
basis
, a
llow
ing u
tilit
ies to
iden
tify
and r
eact to
sig
nifi
cant
cha
ng
es in
no
n-
reven
ue w
ate
r perc
enta
ge.
Dyn
am
ic w
ate
r bala
nce
co
uld
be
imp
lem
en
ted
either
on
th
e e
ntir
e
sys
tem
or
just sm
alle
r m
ore
pro
ble
ma
tic p
art
s of th
e s
yste
m.
Curr
ently
a w
ate
r ba
lance
is p
erf
orm
ed o
n a
bi-m
onth
ly b
asis
. S
ourc
e d
ata
is r
ela
tive
ly a
ccu
rate
an
d t
imely
,
bu
t co
nsum
ption
is a
n e
stim
ate
pulle
d fro
m C
aye
nta
. S
ix m
onth
ly (
3 b
illin
g p
eri
od
s) a
re u
sed to
estim
ate
consum
ption f
or
the t
arg
et b
imon
thly
perio
d. T
his
pro
cess
can b
e im
pro
ved b
y h
avi
ng th
e a
bili
ty to
rep
ort
on
actu
al c
on
sum
ptio
n fo
r a g
ive
n p
eri
od. S
imp
lifyi
ng th
e c
on
sum
ptio
n d
ata
extr
act
wo
uld
lik
ely
allo
w
AC
WD
to p
erf
orm
the w
ate
r bala
nce
mo
re o
fte
n (
like
ly m
onth
ly)
or
be a
ble
to
pe
rform
a b
ala
nce
fo
r ce
rtain
pa
rts
of th
e s
yste
m id
entif
y zo
nes w
he
re w
ate
r p
rod
uctio
n h
as
incr
ease
d f
or
unknow
n r
ea
sons.
DS
6
3
De
tect
Back
flo
w
Even
ts
ICI custo
mers
oft
en
req
uire
ba
ckflow
de
tectio
n d
evic
es (
sin
gle
ch
eck
, dou
ble
check, re
duced
pre
ssure
dete
cto
r, e
tc.)
inst
alle
d o
n c
ert
ain
typ
es
of
wa
ter
serv
ices a
nd c
usto
mers
. O
nce
inst
alle
d, th
e d
evi
ces n
eed
to b
e teste
d a
nnu
ally
to e
nsu
re t
he
y co
ntin
ue
to o
pera
te c
orr
ectly.
AC
WD
has a
n a
ctiv
e c
ross
conne
ctio
n a
nd
ba
ckflow
pre
vention
testin
g p
rog
ram
. A
ltho
ugh
custo
mers
pa
y
for
the tests
, A
CW
D p
erf
orm
s th
e a
nnu
al t
ests
an
d s
en
ds the
resu
lts to t
he
custo
mer.
Where
de
vice
s a
re
no
t op
era
tional, th
e c
usto
mer
is r
equ
ire
d to
make t
he a
ppro
pri
ate
rep
air
s. A
CW
D follo
ws u
p w
ith th
ese
ALA
ME
DA
CO
UN
TY
WA
TE
R D
IST
RIC
T
3
Depe
nd
ing
on w
ho is r
esp
onsib
le f
or
test
ing
, th
e v
alid
atio
n p
rocess
ma
y b
e m
ore
diffic
ult. A
n
AM
I sys
tem
can m
on
itor
cert
ain
acc
ou
nts
to
en
sure
re
vers
e flo
w d
oes n
ot exceed
fo
rward
flo
w,
indic
ating a
back
flow
devic
e is
not o
pera
ting
co
rrectly
. T
hese a
lert
s/a
larm
s th
en a
llow
a w
ate
r
utilit
y to
mon
itor
an
d r
espo
nd
qu
ickly
to
ba
ckflow
even
ts.
cust
om
ers
once t
he r
ep
airs h
ave
been
com
ple
ted t
o r
ete
st th
e d
evi
ce.
AC
WD
has
app
roxim
ate
ly 8
00 s
ites
tha
t a
re te
sted p
er
year.
Ap
pro
xim
ate
ly 1
0%
to 1
5%
of
the
de
vices te
sted p
er
year
fail.
AM
I te
chnolo
gy
will
allo
w A
CW
D to
mo
nito
r th
ese c
usto
mers
fo
r back
flow
an
d th
en
respo
nd w
hen
a d
evic
e b
eco
mes d
efe
ctiv
e,
inste
ad o
f w
aiti
ng t
o t
he n
ext
annu
al in
spectio
n /te
st d
ate
to f
ind o
ut.
Th
is im
pro
vem
ent to
re
sponse t
imes
will
red
uce t
he r
isk o
f sys
tem
conta
min
atio
n.
DS
7
2
By
-law
en
forc
em
en
t
Oft
en b
y-la
w e
nfo
rcem
en
t is
depe
nde
nt o
n c
usto
me
r co
mpla
ints
or
utilit
y p
ers
onn
el dri
ving
thro
ug
h n
eig
hb
orh
ood
s to
iden
tify
custo
mers
who
are
in v
iola
tion o
f a
wate
r enfo
rcem
ent b
an.
AM
I te
chn
olo
gy
can a
llow
a w
ate
r u
tilit
y to
mo
nito
r cu
stom
er
con
sum
ptio
n a
nd h
ighlig
ht
those
who m
ay
be v
iola
ting
the
ban. T
ypes o
f w
ate
r re
str
ictions th
at
can b
e m
on
itore
d:
·
An
aly
ze o
dd /
even
ba
ns
·
Mon
itor
com
ple
te w
ate
r ban
Depe
nd
ing
on t
he f
ine
s is
sued
, th
is m
ay
incre
ase
utilit
y re
venu
es. R
epe
at off
en
ders
cou
ld a
lso
be
fla
gg
ed o
n a
sepa
rate
re
port
to m
ore
clo
sely
mon
itor
them
. S
tric
ter
en
forc
em
en
t du
rin
g a
dro
ugh
t e
vent cou
ld im
pro
ve c
on
serv
atio
n a
nd lea
d t
o r
eductio
ns in
wate
r sup
ply
exp
enses
du
ring
dro
ugh
ts.
Durin
g a
dro
ug
ht, w
ate
r re
str
ictio
ns w
ere
a p
art
of
AC
WD
’s o
vera
ll w
ate
r use r
ed
uctio
n p
rog
ram
in s
upp
ort
of
the
20
14 W
ate
r S
hort
ag
e E
merg
en
cy
Ord
ina
nce
(w
hic
h e
nde
d in
2016).
Bo
th o
dd/e
ven
, d
ay
tim
e a
nd
com
ple
te w
ate
r b
an
s w
ere
re
strict
ions
AC
WD
ne
ed
ed t
o e
nfo
rce
. D
uri
ng t
his
tim
e, th
ere
were
tim
es
whe
n 3
to 4
AC
WD
pe
rso
nne
l were
en
forc
ing t
he w
ate
r re
str
ictio
ns.
Th
ere
are
curr
en
tly
no
wate
r re
str
ictions in
pla
ce, h
ow
ever
duri
ng
a f
utu
re d
roug
ht
event
these a
dde
d A
MI
too
ls to
en
forc
e w
ate
r re
str
ictio
ns w
ou
ld b
e
very
ben
efici
al.
Nota
bly
, th
ere
is a
possi
bili
ty o
f le
gis
latio
n t
hat
would
re
qu
ire A
CW
D t
o e
nfo
rce w
ate
r use
restr
ictio
n.
Havi
ng
a t
ool t
o b
e a
ble
to a
ssis
t w
ith th
is r
eq
uire
ment w
ould
be b
ene
ficia
l.
DS
8
2
Pre
ssu
re
Mo
nit
ori
ng
fo
r
Cu
sto
mer
Co
mp
lain
ts a
nd
fire
flo
w
Pre
ssu
re r
ead
ing
s ca
n b
e ta
ken a
cro
ss a
wate
r sys
tem
on
a d
aily
(or
more
fre
quen
t) b
asis
. T
he
pre
ssure
read
ing
s w
ill e
ithe
r com
e fro
m a
pre
ssu
re g
aug
e o
r a n
on-m
echanic
al w
ate
r m
ete
r th
at
is c
om
patible
with th
e s
ele
cte
d A
MI
techn
olo
gy.
Pre
ssure
rea
din
gs
can
be u
sed f
or
a fe
w
pu
rposes:
·
Bett
er
resp
ond
to c
ust
om
er
pre
ssure
com
pla
ints
.
·
Mon
itor
pre
ssure
for
fire
pro
tect
ion
.
Tw
o a
rea
s w
here
pre
ssure
rea
din
gs w
ou
ld b
e b
en
efici
al:
1.
Custo
me
r C
om
pla
ints
: A
CW
D e
xperie
nced 1
53
pre
ssure
co
mpla
ints
in 2
017
; som
e p
ress
ure
readin
gs m
ay
he
lp r
ed
uce
or
be
tter
resolv
e t
hese t
ypes o
f co
mp
lain
ts.
2.
Fire f
low
mo
nito
rin
g: A
CW
D m
ust
ensu
re th
ere
is a
dequ
ate
pre
ssure
in a
ll pa
rts o
f th
e s
yste
m fo
r
fire
pro
tect
ion
. T
his
activ
ity
takes
two te
chnic
ians
1 o
r 2
da
ys a
week to
ch
eck
pre
ssu
re a
t
hyd
rants
.
DS
11
3
Wate
r D
em
an
d
Fo
reca
sti
ng
an
d
Hy
dra
uli
c W
ate
r
Mo
delin
g
Consu
mption d
ata
ca
n b
e u
sed w
ithin
a h
ydra
ulic
wate
r m
odelin
g s
oft
ware
. T
he g
ranu
lar
consum
ptio
n d
ata
pro
vid
es
a b
etter
un
ders
tandin
g o
n w
here
an
d h
ow
much w
ate
r is
co
nsu
med
with
in t
he
wate
r sys
tem
. T
his
data
ca
n a
lso
be u
se
d to c
om
pare
cu
stom
er
beha
vio
r chan
ges
ba
sed o
n w
ea
the
r.
Wate
r R
esourc
es
ana
lyze
s co
nsu
mptio
n p
atte
rns e
very
fiv
e y
ears
. T
he
y lo
ok a
t past
con
sum
ptio
n b
eha
vio
r
com
pare
d to
wea
the
r pa
ttern
s and t
hen p
erf
orm
a f
ore
cast
of
annu
al and
season
al co
nsum
ptio
n p
att
ern
s
ba
sed
on
gro
wth
pro
jectio
ns fro
m c
ities, w
eath
er
fore
casts
and e
xpecte
d c
ha
nge
s to
con
sum
ptio
n b
eha
vior
movi
ng f
orw
ard
. T
hese
ch
ang
es in
be
ha
vior
ma
y be d
ue to
low
flo
w d
evic
e t
ren
ds, expe
cted r
eba
te
pro
gra
ms, o
r lo
cal a
nd r
egio
na
l conserv
ation
eff
ort
s. A
CW
D u
ses a
ppro
xim
ate
d d
aily
co
nsum
ption p
attern
s
as d
ata
inp
uts
fo
r h
ydra
ulic
mo
delin
g t
o s
uppo
rt e
valu
atio
n o
f op
era
tiona
l an
d c
ap
ital i
mpro
vem
en
t
sce
nario
s. D
ecis
ion
s based
on h
ydra
ulic
mo
delin
g r
esults
are
oft
en la
rge d
olla
r valu
e e
xpen
diture
s (
CIP
item
s).
Eng
ineeri
ng lea
ds a
sys
tem
wid
e c
apacity
ana
lysis
eve
ry 1
0 y
ea
rs to a
id lon
g-t
erm
CIP
pla
nn
ing. T
hey
look
at
past p
eak, sum
mer
and a
vera
ge c
on
sum
ptio
n b
eh
avi
or
to id
entif
y capa
city
lim
itatio
ns w
ith r
eg
ard
to
Pro
ductio
n a
nd D
istr
ibutio
n s
yste
ms.
Accura
te h
ourl
y con
sum
ptio
n d
ata
will
als
o a
ssi
st the P
roje
ct an
d
Ma
inte
na
nce d
ep
art
me
nts
in m
odelin
g long-t
erm
outa
ges r
equir
ed t
o p
erf
orm
variou
s co
nst
ructio
n a
nd
main
tena
nce w
ork
. H
ourl
y consu
mptio
n d
ata
wou
ld a
llow
AC
WD
to b
ett
er
est
imate
daily
con
sum
ptio
n
pa
ttern
s fo
r u
se in
hyd
raulic
modelin
g.
Ho
url
y d
ata
will
als
o im
pro
ve t
he
an
aly
sis
of th
e influen
ce w
ea
the
r
an
d c
usto
mer
daily
ha
bits
have o
n w
ate
r u
se in
a m
uch
more
gra
nula
r b
asi
s,
wh
ich
will
im
pro
ve t
he
Dis
tric
t’s d
em
and
fore
cast
ing.
AM
I ho
url
y con
sum
ptio
n d
ata
will
pro
vide
a b
ett
er
unders
tand
ing t
hat
weath
er
has o
n w
ate
r con
sum
ptio
n b
eha
vior
tha
n th
e c
urr
ent an
aly
sis
wh
ich
is b
ased o
n b
i-m
onth
ly
consum
ption info
rmatio
n.
ALA
ME
DA
CO
UN
TY
WA
TE
R D
IST
RIC
T
4
Ref
Imp
ort
an
ce
Bu
sin
es
s D
rive
rs &
Des
cri
pti
on
AC
WD
En
han
ced
Cu
sto
mer
Se
rvic
e (
CS
)
CS
1
3
Reacti
ve U
se o
f
Leak
Dete
cti
on
Pro
vid
es the
utilit
y w
ith a
n im
pro
ved a
bili
ty t
o r
esp
on
d t
o c
usto
mer’
s hig
h-w
ate
r b
ill c
om
pla
ints
.
AM
I eq
uip
men
t in
clu
de
s a
lgo
rith
ms th
at d
ete
rmin
e a
co
ntin
uo
us o
r in
term
itten
t le
ak.
Diff
ere
nt
typ
es
of
yes/
no f
lags c
an p
rovid
e a
bill
ing a
ge
nt
with
in
dic
ation t
ha
t a lea
k has o
ccurr
ed a
t a
pro
pert
y. T
his
re
activ
e a
pp
roa
ch h
elp
s a
utilit
y be
tte
r serv
ice
its
custo
me
rs.
AC
WD
desire
s th
e a
bili
ty to
bett
er
ma
na
ge c
usto
me
r co
mp
lain
ts r
ea
ctiv
ely
. T
he le
ak
dete
ctio
n f
unctio
nalit
y w
ill
be
used t
o b
ett
er
resp
on
d to
cu
stom
er
who
have
hig
h w
ate
r b
ill c
om
pla
ints
allo
win
g A
CW
D to
pro
vide a
po
ten
tial re
aso
n f
or
the h
igh w
ate
r b
ill. A
CW
D w
ill b
e a
ble
to d
ete
rmin
e if it w
as a
co
ntinuo
us le
ak (
a le
ak in
the
toile
t ta
nk)
or
an e
vent th
at
was ju
st r
ela
ted
to
a c
ou
ple
spe
cific
date
s (f
illin
g t
he p
oo
l).
Ho
wever,
the
pre
fere
nce
is to
pro
vide
leak n
otif
ica
tion
s p
rio
r to
the
cu
stom
er
rece
ivin
g th
e b
ill (
pro
activ
e).
The p
refe
ren
ce
was to p
rovid
e c
usto
me
rs w
ith a
ccess
to s
etu
p th
eir
ow
n a
lert
s v
ia a
custo
mer
port
al o
r by
e-m
ail
to a
lert
the
cust
om
er.
CS
3
3
Pro
acti
ve
Lea
k
Dete
cti
on
Ale
rts
Pro
vid
e leak d
ete
ctio
n n
otif
icatio
n p
rior
to t
he w
ate
r b
ills b
ein
g s
ent
to t
he c
ust
om
er.
This
allo
ws
custo
mers
to
chang
e t
heir
be
ha
vio
r or
investig
ate
po
tentia
l lea
ks p
rior
to r
ece
ivin
g a
hig
h-w
ate
r
bill
. N
otific
ation o
f th
ese
events
can
be
pro
vide
d in
a n
um
ber
of
ways
:
· C
ust
om
er
port
al a
llow
cu
sto
mer
to:
o
vie
w t
heir h
isto
rical c
onsum
ptio
n
o
Set th
eir o
wn
ale
rt c
on
diti
ons
· E
notific
ation
· L
ett
ers
of
hig
h b
ill
· P
ho
ne c
alls
AC
WD
wan
ts to t
ake a
pro
activ
e a
ppro
ach
to le
ak n
otific
ations. N
otif
ica
tion o
f th
ese le
ak o
r hig
h c
onsu
mptio
n
events
will
inclu
de
a c
ust
om
er
po
rtal,
e-m
ail
no
tific
ation,
lett
ers
an
d p
ho
ne c
alls
.
CS
4
3
Cu
sto
mer
Co
nsu
mp
tio
n
An
aly
sis
Pro
vid
e c
usto
me
rs w
ith d
eta
iled c
on
sum
ptio
n d
ata
thro
ug
h a
custo
mer
port
al or
self-
help
kio
sk
locate
d in the
Util
ities c
ust
om
er
serv
ice a
nd b
illin
g d
ep
art
men
t. A
custo
me
r port
al fo
r acce
ss to
wate
r consum
ptio
n c
an inclu
de:
· A
llow
s fo
r consum
ptio
n c
om
pa
riso
ns to:
o
Oth
er
cust
om
ers
avera
ge c
onsum
ptio
n a
cro
ss the
sam
e p
erio
d
o
Com
pa
re a
cu
sto
mer
consum
ption to t
he
ir o
wn
fro
m a
pre
vious p
eri
od
· A
llow
the
cu
stom
er
to v
iew
and
acce
ss th
eir
co
nsum
ption t
hro
ugh
:
o
Gra
ph
th
e c
onsum
ptio
n
o
Ta
bula
te
o
Do
wnlo
ad c
onsum
ptio
n h
isto
ry t
o a
re
port
or
file
.
AC
WD
will
wa
nt to
pro
vid
e c
ust
om
ers
with a
cce
ss to
the
ir c
onsu
mptio
n h
isto
ry t
hro
ug
h a
Custo
mer
po
rtal.
A
single
custo
me
r sig
n-o
n is
pla
nn
ed a
s a p
art
of th
e E
BP
P p
roje
ct (
Invoic
e C
lou
d).
Furt
her
investig
atio
n is
require
d t
o s
ee
ho
w a
custo
mer
will
be d
ire
cte
d t
o a
n M
DM
custo
me
r po
rtal fo
r co
nsum
ption.
Curr
en
tly
there
were
over
27,0
00 c
ust
om
ers
who s
igne
d in
to the e
xis
ting c
usto
me
r port
al w
ith A
CW
D.
CS
5
3
Vac
ati
on
Mo
nit
ori
ng
Allo
w f
or
a c
ust
om
er
to s
et a
va
catio
n a
lert
that
will
tell
the
m if
wa
ter
is b
ein
g u
sed w
hen it
should
not
be
. T
his
would
be s
etu
p t
hro
ugh
a c
ust
om
er
po
rtal w
hic
h a
llow
s fo
r an
ale
rt t
o b
e
sent.
AC
WD
belie
ves
this
is
a v
alu
ab
le f
ea
ture
allo
win
g c
usto
mers
to m
on
itor
the
ir c
on
sum
ptio
n d
urin
g v
acation
or
if
the
pro
pe
rty
is v
aca
nt.
So
cie
tal B
en
efi
ts (
SB
)
SB
1
3C
usto
mer
Wa
ter
Co
nserv
ati
on
There
are
a n
um
be
r of
diffe
rent ty
pe
s of
wa
ter
con
serv
atio
n p
rog
ram
s th
at
focus o
n c
han
gin
g
custo
mers
’ wate
r con
sum
ptio
n b
eha
vior.
The t
ypes o
f pro
gra
ms th
at are
imple
men
ted
with
in a
util
ity
really
de
pen
d o
n t
he c
halle
ng
es fa
ced, custo
me
rs g
rou
ps
(resid
ential, c
om
merc
ial,
and
ind
ust
ria
l) a
nd
th
e t
ype
of
usage
th
e u
tility
is ta
rgeting
(in
doo
r usa
ge,
outd
oo
r usag
e).
AM
I te
chn
olo
gy
can
pro
mo
te w
ate
r co
nse
rva
tion b
y pro
vid
ing
info
rma
tion
to c
usto
mers
wh
ich
enab
les t
hem
to
ch
ang
e t
heir
be
ha
vio
r.
The g
reate
st b
enefit
that
AM
R a
nd
AM
I te
chnolo
gy
can
bri
ng
to
util
ity
dri
ven w
ate
r co
nserv
atio
n
initia
tive
s is
the a
bili
ty t
o ta
rge
t cu
stom
ers
meeting a
spe
cific c
onsum
ptio
n p
rofil
e a
nd t
o
AC
WD
has n
um
ero
us w
ate
r con
serv
ation
pro
gra
ms ta
rgete
d a
t spe
cific
cu
stom
ers
gro
ups a
nd t
ypes o
f usage
.
Th
ere
we
re 3
1 d
iffere
nt w
ate
r conserv
ation
initi
ative
s h
igh
lighte
d in 2
01
5-2
020
Urb
an W
ate
r M
anag
em
en
t
Pla
n. It
was a
com
bin
atio
n o
f re
bate
s for
devic
es
and b
eha
viors
mod
ificatio
ns
that
encoura
ged w
ate
r usag
e
reduct
ion
s and
pu
blic
ou
trea
ch.
Th
e D
istr
ict fe
els
that
AM
I te
chno
log
y co
uld
be u
tiliz
ed
in d
esig
nin
g a
nd
imple
men
ting
the
se p
rogra
ms to
en
sure
AC
WD
is d
ire
ctin
g c
onserv
ation r
eso
urc
es a
t th
e r
ight
pro
gra
ms a
nd c
usto
me
rs. E
nh
an
cin
g
conserv
ation w
ill o
ffse
t th
e p
ote
ntia
l nee
d to
de
velo
p fu
ture
, m
ore
expen
siv
e, w
ate
r su
pplie
s s
uch a
s re
cycl
ed
wate
r.
ALA
ME
DA
CO
UN
TY
WA
TE
R D
IST
RIC
T
5
Ref
Imp
ort
an
ce
Bu
sin
es
s D
rive
rs &
Des
cri
pti
on
AC
WD
measure
th
e a
ffe
cts w
ate
r conserv
ation
pro
gra
ms h
ave
on r
edu
cing w
ate
r co
nsu
mp
tion
. A
s a
resu
lt, p
rogra
m d
olla
rs c
an
be
be
tte
r ta
rgete
d a
nd
utiliz
ed
to
ward
s p
rogra
ms
that
are
pro
ven
to
be th
e m
ost e
ffect
ive.
ACWD JOB 10062 Water Focused Customer Portal RFP 50
Appendix E – Current Invoice Cloud and CSS System Architecture Diagram