Développements de la microspectrométrie et transfert vers l’industrie E. Le Coarer RESIF

RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Développements de la microspectrométrie et transfert vers l’industrie

E. Le Coarer

RESIF

Page 2: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Grenoble, a Space City in the Alps

Page 3: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

NanoCarb-drone

[email protected] - NanoCarb - CRISTAL

3

Interference plane 633nm

Telescope 50mm

Field mask6x6mm2

Lcol

D=30mmF=75mm

µLPitch=0.3mmF=4mm

CMOS Hdpix2808x1096

Integration of 1 on-drone hyperspectral sensor based on NanoCarb/ATISE hybrid concept Study of vegetation [Laurent Borgniet (IRSTEA), Laurence

Audin (ISTERRE)] 14 spectral channels between 400nm and 1000nm 30x30 pixels of field 6m-swath at an altitude of 50m, and with a spatial

resolution of 20cm

Focal plane

Page 4: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Cubesat 1U

(1 k

g, 1

W, 1

L) 10 cm

10 cm

NanoCarb 6U

The NanoCarb Mission

Unit 1Unit 2

Unit 3

Sun-synchronous orbit Constant local time 11:30 am Altitude: 594 km 21 x 5min time-spaced units

A constellation of 21 cubesats to complete the MicroCarb mission with daily resolved data Implementation of a SPOC imaging spectrometer, swath=150km Multiplication of the satellites on the orbit (x10-21) Resolution: 3km Sensitivity: goal 1 ppm of CO2 ; 32ppb of CH4

Land coverageNadir mod

Ocean coverageGlint mod

[Mic

roC

arb

]

Need a drastically miniaturized payload10-100kg => 1-10kg

Design a SPOC-based imaging-FTS

Performance demonstration

10/08/2017 4

Page 5: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

SPOC-based spectro-imager designSid

e view

(no

t to sca le

)Fro

nt view

4x optically independent spectral bands4x spectral bands over one single detector

… or 1 detector/band

Payload: 150x40x40 mm3

Estimated consumption ~10W, FPA: 1WIntegration in a 6U-12U platform (<10kg for 6U)

Implementation example in a 6U plateform [ISIS]

10/08/[email protected] - NanoCarb Séminaire OSUG

5

Page 6: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

VIPA : high spectral resolution echelle spectrometer

Page 7: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

7

Applications

Photonics AeronauticsStructure Health Monitoring

Bio-pharma

L a s e r S p e c t r u m A n a l y z e rW a v e l e n g t h M e t e r

B r a g g I n t e r r o g a t o r R a m a n A n a l y z e r

Laser characterization Process analyticsStructure monitoring

ProCellics™

Page 8: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

8

Products for laser analysis

ZOOM Spectra

630-1100 nmUltra-high spectral resolution (2 GHz) High-rate (30 kHz)High absolute accuracy (600 MHz)Trig availableGigaEthernet

MICRO Spectra

630-1100 nmUltra-high spectral resolution CompactUSB2.0

WIDE Spectra

630-1100 nmUltra-high spectral resolution Wide measurement windows (100 nm)USB2.0

OEM-MICRO Spectra

630-1100 nmUltra-high spectral resolution Ultra compactUSB2.0To be embedded

LW-10 Wavelength Meter

20 MHz resolution

200 MHz absolute accuracy

For pulsed and CW lasers

User-friendly software

Compact size

For single frequency lasers only

Tunable laser control

Laser stability control

Frequency locking

Key features Applications

Page 9: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

GeoSWIFTS: a nano strainmeter using optical fiber / Bragg gratings and an optically integrated spectrometer

O. Coutant, ISTerre, UGA

E. Le Coarer, IPAG, UGA

F. Thomas, Resolution Spectra

M. De Mengin, SITES Sas

e

Page 10: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

GEOSWIFTS Objectives

• Take opportunity of SWIFTS spectrometer characteristics to develop a field and borehole strain sensor using Bragg Gratings on optical fiber

• Such sensors are extremely usefull to records transient signals:– Precursors to earthquake– Precursors to eruption– Transient « long term » deformation (Slow Slip Event)– – They need to resolve down to 1.e-9 strain

• • Optical fibers are a good candidate for borehole

installation • (temperature >80°C, chemical immunity, …)

Page 11: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Example 1: Eruption Soufriere Hill, Montserrat, 2003, Voight et al., 2010, GRL

Strain Signal associated with pyroclastic eruption recorded by a mechanical Sacks-Evertson borehole sensor

Deformation: Volcanology

Page 12: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Slow earthquakes triggered by typhoons, Liu, Linde & Sacks, Nature, 2009

Strainmeter at Taiwan above the subduction zone

Deformation: slow slip event subduction zone

Page 13: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Principle of operation for Bragg gratings optical fiber strain measurement

A Bragg grating inside the optical fiber (periodic variation of light index) acts as a mirror for a given wavelength l depending on the periodicity

Light sourceLight source

l shifMeasurement

using spectrometer

l shifMeasurement

using spectrometer

Page 14: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Pierre Kern / ICSO 5 October 2010

SWIFTS-Lippmann Principle

Wave-guide core

Wave-guide Substrate

Nano-detectors in evanescent field

Stationary wave

Lippmann Interferogram

Monochromatic light case

White light case

Wave-guide core

Wave-guide SubstrateNano-detectors in

evanescent field

Light entrance

Mirror

4 m

Light entrance

Page 15: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Pierre Kern / ICSO 5 October 2010

SWIFTS-Lippmann Principle

Wave-guide core

Wave-guide Substrate

Nano-detectors in evanescent field

Stationary wave

Lippmann Interferogram

Monochromatic light case

White light case

Wave-guide core

Wave-guide SubstrateNano-detectors in

evanescent field

Light entrance

Mirror

4 m

Light entrance

Interference fringes

Page 16: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

SPIE – Photonics West – Paper 8992-16 - Photonic Instrumentation Engineering – 3th February 2014

Implementation of the technology

Hybridization on camera

Precise alignment and bonding of the “optical” chip on a detector die (2048 pixels high-rate linear CCD detector)

Fiber connectorization to the singlemode waveguide

Assembly with electronics and mechanical package

High-resolution high-rate mini-spectrometer without any moving parts

= the ZOOM Spectra spectrometer

Page 17: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Coutant, O.; De Mengin, M. & Le Coarer, E.Fabry--Perot optical fiber strainmeter with an embeddable, low-power interrogation systemOptica, Optical Society of America, 2015, 2, 400-404

Page 18: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

The optical fiber deformation is proportional to the interference fringe displacement

Page 19: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Experiments at Rustrel LSBB underground facility

• 1st design: Fabry-Pérot ~2cm vertical sensor• 2nd design: Michelson 20m horizontal sensor

Page 20: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Fabry-Pérot vertical 2cm strainmeter

Page 21: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Earth tide recording

Page 22: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

0 500 1000 1500 2000 2500 3000 3500−100

−80

−60

−40

−20

0

20

40

60

80

sec

na

nost

rain

Strain estimated from seismometers network

0 500 1000 1500 2000 2500 3000 3500−80

−60

−40

−20

0

20

40

60

80

sec

na

no

stra

in

Strain measured from geoswifts

above 25e−9 strain noise level

below 25e−9 strain noise level

Chile Mag 7.8 earthquake recording

Page 23: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

2cm Fabry-Pérot noise level

Page 24: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Michelson 20m horizontal sensor

Page 25: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Fox Island Mag 6.9 earthquake recording

Page 26: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Fox earthquake: Amplitude and phase matching

Page 27: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

20m Michelson noise level

Page 28: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

20m Michelson noise level

Noise ?

Page 29: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

20m Michelson noise level

Noise ?

The 20m Michelson is unable to detect the earth tide

Page 30: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

0 2000 4000 6000 8000 10000 12000 14000 16000964

964.5

965

965.5

966

966.5

967pressure

0 2000 4000 6000 8000 10000 12000 14000 16000−1.5

−1

−0.5

0x 10

−6 deformation

Coupling between pressure and deformation may shadow earth tide signal

Page 31: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

13.5 14 14.5 15 15.5 16−1

−0.5

0

0.5

1

1.5x 10

−8

hours

stra

in

Mariana Mag 7.7 deep earthquake (29−07−16)

noise rms: 0.4e−9

Page 32: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

PerspectivesRealization of borehole mono or multiaxial optical fiber sensor using EBM technology (3D titanium impression):

Path indicator

Fiber Path guide

Up to 6 axes

Clamping screw threading

Prototype using 3D plastic impression

Titane 3D printedPorous sample

Page 33: RESIF Développements de la microspectrométrie et transfert ... · A constellation of 21 cubesats to complete the MicroCarb mission with daily ... −80 −60 −40 −20 0 20 40

Conclusion

• Demonstration of small efficient FP fully integrated sensors

Development of borehole instrumentation

• Very sensitive sub-nano Michelson instrumentation – Difficulties to interpret

signals but very promizing

e