Revisimo Re mote Vi tal Si gn Mo nitor TM

Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Embed Size (px)

Citation preview

Page 1: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Revisimo

Remote Vital Sign Monitor

TM

Page 2: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

About us

Dr. Thomas Morris

Advisor

Cory Zywno

EE

•Coordinator•Thermo- Dynamics•Calibration

MatthewGalloway

EE

•Temperature Conversion•Thermo- Dynamics •Calibration

MatthewGallups

EE

•Alarm•Battery Life•SPI Interface

AaronCheeseman

EE

•User Interface•PCB design•Battery Life

PaulJang

CPE

•RFD•SPI Interface•User Interface

Page 3: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Overview

• Problem/Solution• Constraints

– Technical– Practical

• Testing– Hardware– Software– System

• Future Goals• Questions

Page 4: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Problem

• Market (oral, tympanic, scanning)– Inaccurate & No Programmable Alarm– Difficulty of Continuously Monitoring

• Hospital equipment– Expensive– Mobility is Restricted– Hard to use

Page 5: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Solution• What is Revisimo?

– Digital wireless Thermometer

• Bandage• Wireless• Temperature

Sensing Device• Monitor

• Alarm• Temperature set

by the user

Page 6: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

System Overview

Page 7: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Constraints

Page 8: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Technical Constraints

Battery Life Revisimo must have a minimum battery life of seven days.

Wireless The bandage and monitor must communicate with

each other within a 100-foot radius (indoors). Alarm System The alarm must be triggered if a user defined

temperature is reached. Also, the alarm must be audible from at least 30 feet away.

Temperature Precision

Revisimo must calculate the core body temperature within 0.5 °F. Revisimo must read temperatures within the range of 65 °F to 110 °F.

Visual Distance The display must present data to the user at a distance of up to 3 feet.

Page 9: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Manufacturability

• The bandage must fit on the temple and the monitor must be handheld.

Page 10: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Political

• Revisimo must abide by Federal Communications Commission regulations and allocations of the radio spectrum (9kHz to 3THz).

Page 11: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Battery Life

• Current Draw (Low Power Mode): 5.1 mA

• Current Draw (Active Mode): 35.6 mA

• 4ms transfer time

• mA-h= 855.01+.27= 855.28 mA-h

• A coin cell battery of 900 mA-h to 1000 mA-h will be sufficient.

Page 12: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Hardware Testing

Page 13: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Operating Range

Description Displacement Pass/Fail

Case 1 Same Floor (Line of Site) 163 Feet Pass

Case 2Same Floor, 1 Hall (Non Line of Site) 152 Feet Pass

Case 3Same Floor, 2 Halls (Non Line of Site) 59 Feet Pass

Case 4 1 Floor up (Non Line of Site) 164 Feet Pass

Case 5 1 Floor up, 1 Hall (Non Line of Site) 115 Feet Fail

Case 6 2 Floors Down (Non Line of Site) 44 Feet Pass

Case 7 3 Floors Down (Non Line of Site) 31 Feet Fail

Page 14: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Alarm Audibility

• The alarm was tested for audibility from thirty feet away.

• The alarm operates at 245 Hz and approximately 3Vpp

Page 15: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Display Readability

• The monitor was setup three feet away from the user.

• The test concluded that the LCD could lucidly be seen from three feet away.

Page 16: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Software Testing

Page 17: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

User Interface (UI)

Page 18: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Display

Page 19: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Display

Page 20: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Display

Page 21: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Temperature Calibration

Measured Voltage (V) Calculated Temp (F) IR Temp (F) Thermocouple Temp (F) Calculated/IR Average Constant

0.654 95.07 96.2 96 1.0118 1.0288

0.64 96.18 99.6 98 1.0355

0.605 99.31 102.3 102 1.0301

0.586 100.67 104.5 104 1.0380

Measured Voltage (V) Calculated Temp (F) IR Temp (F) Thermocouple Temp (F) Calculated/IR Average Constant

0.679 93.13 96 96 1.0308 1.0415

0.64 96.18 100.4 99 1.0438

0.623 97.56 101.8 102 1.0434

0.602 99.31 104.1 104 1.0482

Thermistor 1 Calibration

Thermistor 2 Calibration

Page 22: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

sbss

bc TTTh

hT

Digital Thermometer (F) Skin Thermistor 1 (F) Skin Thermistor 2 (F) Buried Thermistor 1 (F) Calculated Core Body Temperature (F)

98.9 95.57 97.96 91.38 102.15

95.28 97.98 91.09 102.17

95.45 97.96 90.95 102.46

95.5 97.86 90.93 102.43

1399.s

b

h

h

Temperature Calibration

Thermal Conductivity of Bandage and Skin

Page 23: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Temperature Calibration

Digital Thermometer (F)

Calculated Core Body Temperature (F)

Temperature Difference (F)

98.4 96.1 2.3

97.4 1.0

96.2 2.2

96.0 2.4

95.8 2.6

IR Thermometer (F) Surface Temperature 1 (F) Surface Temperature 2 (F) Difference (F)

105.0 102.8 104.3 .7

102.5 103.9 1.1

102.8 103.9 1.1

102.9 103.9 1.1

Hot Plate Results

Temple Region Results

Page 24: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

System Testing

Page 25: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

System Tests

Page 26: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Sunny Day Case

Page 27: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Rainy Day Case

Page 28: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Future Plans

• Increase Temperature Accuracy• Control Layer PCB

– Antenna– Battery– Microcontroller

• Monitor PCB– Antenna– Battery– User Interface– Microcontroller

Page 29: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Questions

Page 30: Revisimo Remote Vital Sign Monitor TM. About us Dr. Thomas Morris Advisor Cory Zywno EE Coordinator Thermo- Dynamics Calibration Matthew Galloway EE Temperature

Reference

• [1]http://www.accesshealth.com.au/sample/107/122/Meas_Therm_Reister_Tympanic_250_x_489_1024.jpg

• [2]http://ec2.images-amazon.com/images/P/B00004C8SV.01._SS400_SCLZZZZZZZ_V1057215662_.jpg

• [3]http://ecx.images-amazon.com/images/I/312EW9VHJNL._SL500_AA280_.jpg

• [4]http://www.tmhfoundation.com/images/fundraisingobjectives_pic3.jpg

• [5]http://en.wikipedia.org/wiki/File:US-FCC-Seal.svg