  • RF and MicrowaveInstallation and

    Maintenance

    Cung DuongRF uW Application Engineer

    Carry Precision with You

  • AgendaCarrying precision into the field

    • Advances in bench-top instruments.

    • Carrying Bench-top precision into the field.

    • The FieldFox analyzer and Application Accurate, rugged, portable, and flexible

    • Q&A

    Slide 2

  • Change Multi-Station Process to Single Instrument

    Old way: multiple test stations needed to complete required tests

    Gain, match, isolation Pulsed-RFIMD, spurs,harmonics, noise figure

    New way: one instrument does it all!

    Slide 3

  • Leverage Your Investment to a Wide Range of Applications

    www.agilent.com/find/pnax

    AntennaTest

    T/R ModuleTest

    Mm-wave

    Load pullNoise parameters

    Single Connection:Gain compression,IMD, noise figure,

    harmonics,true differential,

    PAE, hot S22

    Mixer Test

    Amplifier TestPulsed RF

    and DC

    Scanning Microwave Microscope

    Materials Measurements

    Signal Integrity

    NVNAComponent characterization

    X-parameter extractionPulse envelope domain

    PNA-XPNA-X

    13.5 GHz13.5 GHz

    43.5 GHz43.5 GHz50 GHz50 GHz

    26.5 GHz26.5 GHz

    67 GHz67 GHz110 GHz110 GHz

    Slide 4

  • CXAX-SeriesLow cost9 kHz to 26.5 GHz

    EXAX-Series Economy class10 Hz to 44 GHz

    Agilent X-Series Signal AnalysisAn evolutionary approach to signal analysis that spans instrumentation, measurements and software

    Performance

    ESAWorld’s most popular 100 Hz to 26.5 GHz

    Pric

    e

    HSA

    MXAX-Series Mid performance 10 Hz to 26.5 GHz

    PSAMarket leading performance 3 Hz to 50 GHz

    89601B VSA softwareSee through the complexity!

    Expanded backward codecompatibility with 8566/68 on PXA /MXA/EXA

    Sep 06

    Sep 07

    PXAX-SeriesHigh performance 3 Hz to 50 GHz

    Sep 09

    Sep 09

    N9320B Basic-performance9 kHz to 3 GHz

    Slide 5

  • Flexibility to cover diverse needs • Highest Frequency Range, Widest

    Bandwidth, Highest Dynamic Range and Accuracy.

    • Coupled with 89600 VSA software, our X-series Analyzers provides more measurement applications and demodulation capabilities.

    The Only future-ready signal analyzer on the market• Hardware expansion• CPU, SSD upgrades• License key upgrades

    A G I L E N T X ‐ S E R I E S S I G N A L A N A LY S I S P L AT F O RM

    2 expansion slots

    Anticipating technology evolutions 

    Slide 6

  • Agilent X-Series Measurement ApplicationsBroad Application Coverage – covering today’s multi-format needs

    LTE-FDDLTE-TDD

    W-CDMA/HSPA/HSPA+TD-SCDMA/HSPA

    GSM/EDGE/EDGE Evocdma2000/cdmaOne

    1xEV-DOiDEN/WiDEN/MotoTalk

    802.16 OFDMAFixed WiMAX802.11 WLAN

    Bluetooth

    Digital Cable TVDVB-T/H/T2

    ISDB-T/TSB/TmmDTMB (CTTB)

    CMMB

    VXA vector signal analysisAnalog demodulation

    Phase noiseNoise figure

    MATLABPulseEMC

    Remote & SCPI language compatibility

    Cellular Communication

    Wireless Connectivity

    Digital Video

    General Purpose

    Slide 7

  • AGILENT TECHNOLOGIES’ RF SIGNAL GENERATION

    MXG N5182A100 kHz to 6 GHz

    ESG E4428C250 kHz to 6 GHz

    MXG N5181BAnalog9 kHz to 6 GHz

    ESG E4438C250 kHz to 6 GHz

    EXG N5171BAnalog9 kHz to 6 GHz

    MXG N5181A100 kHz to 6 GHz

    EXG N5172BVector 9 kHz to 6 GHz

    MXG N5182BVector 9 kHz to 6 GHz

    THE WORLDS BESTPERFORMANCE

    MOST SOPHISTICATEDREAL‐TIME APPLICATIONS

    LOWEST COST OF OWNERSHIP

    T H E N EW X ‐ S E R I E SS I G N A L G E N E R AT O R S

    Code compatible

    Slide 8

  • AGILENT SIGNAL STUDIO & EMBEDDED SOFTWAREMOST COMPREHENSIVE & SOPHISTICATED APPLICATIONS

    LTE/LTE-Advanced FDD + MIMO

    LTE/LTE-Advanced TDD + MIMO

    W-CDMA/HSPA+

    GSM/EDGE/Evo

    cdma2000/1xEV-DO

    TD-SCDMA/HSDPA

    WLAN 802.11a/b/g/n/ac +MIMO

    Mobile WiMAX +MIMO

    Bluetooth- V1.1, V2.1+EDR

    - Low Energy

    Digital Video- DVB-T/H/T2/C/S/S2- J.83 Annex A/B/C- DOCSIS DS - ISDB-T/TB/TSB/Tmm- DTMB(CTTB)- CMMB- ATSC, ATSC-M/H

    Broadcast Radio:- FM Stereo/RDS- DAB/DMB/ETI

    GNSS ‐ GPS‐ GLONASS

    Toolkit

    Multitone

    Phase Noise Impairment

    Calibrated Noise (AWGN)

    Custom Modulation 

    MATLAB

    ADS / SystemVueSignal Studio software

    Embedded software

    Partner products

    Legend

    Cellularcommunications

    Wireless connectivity

    Audio/video broadcasting

    GeneralRF & MW

    Detection, positioning, tracking & navigation

    5 Pack & 50 Pack Waveform Licensing

    Slide 9

  • Leverage our Legacy of Measurement Leadership

    FieldFox analyzers are the handheld extension of the best network and

    spectrum analyzers.

    “FieldFox’s result is almost identical to my PNA. I want one of these for all of my engineers.”-Senior calibration engineer from spacecraft research and development center.

    Slide 10

  • Challenges in the FieldCarrying precision into difficult environments

    Unpredictable situations

    Mission critical Crowded conditions Harsh environments

    • Unforgiving conditions

    • Unknown hazards

    • Mission critical decisions based on measured data

    • High pressure & time sensitive

    • Tight quarters

    • No room for error

    • Dark, rainy, windy, dusty, slippery, glaring, scorching

    • Fluctuating & extreme temperatures

    “The technology Agilent has developed is simply superior.”- Major aerospace/defense prime contractor

    Slide 11

  • Taking a Closer LookFieldFox - the new industry-standard

    • Get precise measurements that agree with benchtop results• Industry-leading amplitude accuracy of ± 0.5 dB• Low trace noise of ± 0.004 dB and superior dynamic range of 94 dB• InstAlign, CalReady, and QuickCal

    Accurate

    • Dust-free design with no fans or vents• Water-resistant• 3-year warranty ensures field confidence• Viewable in direct sun/darkness• MIL-spec durability

    Rugged

    • Configure as cable and antenna analyzers, vector network analyzers, spectrum analyzers, or all-in-one combination analyzers

    • Choose the right frequency, functionality, and price • Easily add extra options later by simply adding a license key – no extra hardware required

    Flexible

    • Compact and lightweight (3.0 kg or 6.6 lbs), long battery life (3.5 hrs)• Wide operating temperature -10 to +55 °C (14 to 131 °F)• Vertical orientation and large buttons make it easy to operate with one hand – even with gloves

    Portable

    Slide 12

  • Carry Benchtop Accuracy into the Field with InstAlign, CalReady, and QuickCal

    • Provides industry-leading amplitude accuracy of ± 0.5 dB at power-up, no warm up required

    • Allows field users to instantly and precisely characterize transmitter power• Power measurements agree benchtop instruments• As environment conditions change, such as temperature, alignment automatically adjusts without user intervention

    InstAlign – automatic amplitude alignment

    • Instrument is already calibrated at power on or preset and is ready to go without additional steps to calibrate

    • Immediately ready to make calibrated measurements at the test ports

    CalReady

    • Built-in calibration - calibrate without a calibration (cal) kit• With other instruments, adding devices such as jumper cables to the test port requires recalibrating with an external cal kit

    • It automatically corrects for phase shift and loss of cables and adapters and electrically moves the calibration plane to the end of these components

    QuickCal

    New

    Slide 13

  • InstAlign: No Warm-up RequiredIndustry-Leading Spectrum Analyzer Amplitude Accuracy

    FieldFox marker reading: -25.05

    dBm

    Agilent power meterreading: -25.04 dBm

    Enables transmitter calibration in the field even during temperature variation.

    Slide 14

  • FieldFox delivers benchtop accuracy to the field.

    ~ 2 hours

    Agilent FieldFox

    microwave spectrum

    analyzer from cold start

    Competitor microwave spectrum

    analyzer from cold start

    Agilent U2002A microwave

    power sensor

    FieldFox vs. competitor amplitudemeasurements in dBm from 10 °C to 50 °C

    (PXA and power meter as reference) Agilent PXA

    in cal, warmed up

    InstAlign Provides Superior Accuracy Performance Matching high performance benchtop

    Slide 15

  • FieldFox Delivers Superior Phase Noise

    Enables detection of close-in low level signals previously only detectable by high-end benchtop instruments (-111 dBc/Hz @ 10 kHz offset).

    Phase noise at 1 GHz: FieldFox vs. ESA

    ~15 dB better than

    the ESA

    Slide 16

  • World’s Most Capable Handheld Spectrum Analyzer

    Designed for Field Use InstAlign: Total absolute amplitude

    accuracy 0.5 dB over -10 to +55 °C, No warm up req’d

    Phase noise: -111 dBc @ 10 kHz offset (-10 to +55 °C)

    Full band pre-amp and tracking generator, optional reflection measurements

    Interference analyzer with spectrogram and record/playback

    Frequency counter with internal, external or GPS reference

    Independent source with -45 dB power level control

    IF output: 5 to 25 MHzAM/FM tune & listen

    5 kHz to 9, 14, 18 & 26.5 GHz

    Slide 17

  • Carry VNA Benchtop Accuracy into the Field

    Slide 18

  • Microwave FieldFox Compared to PNA-X

    Delta Marker S11 S21 Mkr 2 Passband 0.02 dB 0.02 dBMkr 1 Left Filter Skirt 0.02 dB 0.52 dB @ 78 dB downMkr 3 Right Filter Skirt 0.00 dB 0.11 dB @ 65 dB down

    DUT is 10.24 GHz Passband Filter

    Slide 19

  • World’s Most Accurate Handheld CAT or VNA

    Benchtop Accuracy8510 & PNA-X measurement

    science & calibration algorithmsCalReady: Immediately ready to

    make calibrated measurements at the test ports

    QuickCal: Built-in calibration, no external devices needed

    Stability spec 0.01 dB/°C Dynamic range up to 100 dB,

    trace noise 0.004 dB to 20 GHzDistance to fault or full time domain

    with gatingGuided calibration wizard including

    unknown thru cal2 MHz to 4 or 6 GHz30 kHz to 4, 6.5, 9, 14, 18 & 26.5 GHz

    Slide 20

  • World’s Most Integrated & Accurate Combo Analyzer

    Ten Instruments in oneCATFull 2-Port VNA, time domainSpectrum analyzer Independent source with leveled,

    - 45 dB adjustable power Interference analyzer & recorderFrequency counter with SAChannel power or USB power sensor

    supportDC supply & current monitor

    (0 to 32 volts, 0.7 A max)Vector voltmeterBuilt-in GPS receiverAll FieldFox options are available and

    upgradable on the combination analyzer

    5 kHz to 4, 6.5, 9, 14, 18 & 26.5 GHz

    21X-Series Measurement Application

    Revised April 2013

  • Combination Analyzer: 10 Instruments in 1

    Cable and antenna analyzer30 kHz to 26.5 GHz

    Full 2-port vector network analyzer with time domain

    analysis, 30 kHz to 26.5 GHz

    Spectrum analyzer, with full-band tracking generator

    5 kHz to 26.5 GHz

    Power meter5 kHz to 26.5 GHz

    Independent signal generator30 kHz to 26.5 GHz

    Vector voltmeter, 2-port30 kHz to 26.5 GHz

    Interference analyzer

    Variable DC source andcurrent monitor Light weight: 6.6 lbs (3.0 kg)

    Long battery life: 3.5 hrsBright display: 6.5 inch TFTMIL-PRF-28800 F Class 2MIL-STD-810G, 511.5, Proc 1Built-in GPS receiver Frequency counter

    Slide 22

  • Get a Wide Range of Precise Field Measurements

    Plus:Built-in GPSIndependent sourceFull-band preamplifierSA frequency counter

    Spectrum analysis

    Cable and antenna analysis,Incl DTF,RL,VSWR

    Vector network analysis

    Built-in power meter & USB power sensor support

    Vector voltmeterInterference analysis & recording Full-band tracking generator Channel power measurement

    Time domain & Gating DC source & current monitor

    Slide 23

  • Rugged Enough to Meet MIL-PRF-28800F Class 2

    Field-proof Completely sealed instrument enclosure provides measurement stability in harsh environments

    3-year warranty ensures field confidence (standard on all FieldFox analyzers)

    Water-resistant chassis, keypad, and case withstand wide temperature ranges, and salty, humid environments

    • Case withstands shock and vibrations• Wide operating temperature -10 to +55 °C (14 to 131 °F)• Wide storage temperature -51 to +71 °C (-60 to 160 °F)

    MIL-spec durabilityMeets MIL-PRF-28800F Class 2 requirements for temperature, humidity, shock, vibration and bench drop

    Type tested and meets MIL-STD-810G, Method 511.5 Procedure I requirements for operation in explosive environments

    New

    New

    Slide 24

  • Portable - Pick up FieldFox for its Ergonomics

    One-button measurements simplify complex setups and ensure quick, accurate results

    Bright, low-reflective display and backlit keys enable easy viewing in darkness or direct sunlight

    Large keys are easy to operate, even when wearing gloves

    Weighing just 3.0 kg (6.6 lbs)FieldFox is easier to carry than similar analyzers

    The intuitive user interface is designed for the work you do every day, enabling measurements in just a few key presses

    Vertical portrait orientation makes FieldFox comfortable to hold, and the keypad layout lets you easily operate it with your thumbs

    “I really like the packaging, and you’ve done a lot to simplify the controls and menus.”- DoD technical lead for military contracts

    Slide 25

  • …and Depend on its Durability

    Rubber doors protect connectors from dust and moisture

    Specially designed connector bay protects connectors from damage due to drops or other external impacts

    Keep going with the easily replaceable Lithium Ion battery

    Gasketed doors protect connectors from dust and moisture

    Transfer and archive data through LAN, USB and SD card

    Slide 26

  • 18 GHz

    26.5 GHz

    N9912A-104

    N9912A-106 N9923A-106

    N9923A-104

    Agilent Expands Handheld Portfolio

    9 GHz

    14 GHz

    4 GHz

    6 GHz

    CAT only VNACombination analyzer Spectrum analyzer HSA

    20 GHz

    13.4 GHz

    7 GHz

    3 GHz

    N9330B N9340B

    N9342C

    N9344C

    N9343C

    N9913A

    N9918A

    N9917A

    N9916A

    N9915A

    N9914A

    N9925A

    N9927A

    N9926A

    N9928A N9938A

    N9937A

    N9936A

    N9935A

    14 new models

    Aug 31st

    • Accurate• Rugged• Portable• Flexible

    Slide 27

  • Feature ComparisonAll features are license upgradeable

    Available functions Combinationanalyzers

    Vector network analyzers

    Spectrumanalyzers

    Cable and antenna analysis

    Vector network analysis

    Spectrum analysis

    Interference analysis

    Full-band preamplifier

    Full-band tracking generator and independent source

    Built-in power meter

    Vector voltmeter

    Built-in GPS receiver

    Slide 28

  • New Microwave Accessories

    Cal kits: 6, 9, 18 and 26.5 GHz

    Yagi AntennaCell and PCS Waveguide cal kits

    Microwave Test Cables

    Adapters

    Trigger, IF, DC out cable

    Slide 29

    Hard and soft transit cases

  • Additional Information

    • Application note series• Interference analysis, cable and antenna analysis,

    calibration and alignment, time domain, power measurements, and site survey

    • Product literature• Family brochure, technical overviews, data sheet,

    configuration guide, tri-fold photo card• Product introduction and demo videos

    www.agilent.com/find/FieldFox

    • Educator’s corner – Your education resources• Teaching Tools and Instruments• Free Experiments• Researchers’ Corner• Student Resource Center

    www.agilent.com/find/education

    Slide 30