Water Tankless Water Heaters Commercial Submittal Sheet PRINTED IN U.S.A. 09/18 WP FORM NO. TK-RTR-SUBMIT INTEGRATED HOME COMFORT Job Name: ___________________________________________________________________________ Location: _____________________________________________________________________________ Architect/Engineer: ___________________________________________________________________ Contractor/Plumber: __________________________________________________________________ Water Heater Schedule: _______________________________________________________________ (ex. WH-1 - WH-12) Rheem ® Commercial Tankless Water Heater Submittal Sheet COMMERCIAL COMMERCIAL COMMERCIAL Commercial Tankless Models System: RTR = Rheem Tankless Rack Will contain RTGH-CM95 tankless water heaters Configuration: FS = Free Standing WM = Wall Mount WH = Wall Hanging Venting: DV = Direct Vent / Indoor X = Outdoor Emissions: L = Low NOx Gas Type: P = Propane N = Natural Gas Units on rack (max tankless for configuration, units on front, units on back) First Digit = 2, 3, 4, 6 = Max possible units for configuration Second Digit = 1, 2, 3 = Actual units on front Third Digit = 0, 1, 2, 3 = Actual units on back RTR-WM 330 X L P TANKLESS MODEL INDOOR NATURAL GAS INDOOR LIQUID PROPANE OUTDOOR NATURAL GAS OUTDOOR LIQUID PROPANE Model Number RTGH-CM95DVLN RTGH-CM95DVLP RTGH-CM95XLN RTGH-CM95XLP Quantity Needed Rheem Commercial Tankless Water Heaters Controls included Condensate neutralizer included Communication cables included Isolation and pressure relief valves included

Rheem Commercial Tankless Water Heater …...Rheem® Commercial Tankless Water Heater Submittal Sheet L L L Commercial Tankless Models System: RTR = Rheem Tankless Rack Will contain

  • Upload
    others

  • View
    60

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Rheem Commercial Tankless Water Heater …...Rheem® Commercial Tankless Water Heater Submittal Sheet L L L Commercial Tankless Models System: RTR = Rheem Tankless Rack Will contain

Water INTEGRATED HOME COMFORTTankless Water HeatersCommercial Submittal Sheet

PRINTED IN U.S.A. 09/18 WP FORM NO. TK-RTR-SUBMIT

INTEGRATED HOME COMFORTINTEGRATED HOME COMFORT

Job Name: ___________________________________________________________________________

Location: _____________________________________________________________________________

Architect/Engineer: ___________________________________________________________________

Contractor/Plumber: __________________________________________________________________

Water Heater Schedule: _______________________________________________________________ (ex. WH-1 - WH-12)

Rheem® Commercial Tankless Water Heater Submittal Sheet

COMMERCIAL

COMMERCIAL

COMMERCIAL

Commercial Tankless Models

System:

RTR = Rheem Tankless Rack

Will contain RTGH-CM95 tankless water heaters

Configuration:

FS = Free Standing

WM = Wall Mount

WH = Wall Hanging

Venting:

DV = Direct Vent / Indoor

X = Outdoor

Emissions:

L = Low NOx

Gas Type:

P = Propane

N = Natural Gas

Units on rack (max tankless for configuration, units on front, units on back)

First Digit = 2, 3, 4, 6 = Max possible units for configuration

Second Digit = 1, 2, 3 = Actual units on front

Third Digit = 0, 1, 2, 3 = Actual units on back

R T R - W M 3 3 0 X L P

TANKLESS MODEL INDOOR NATURAL GAS INDOOR LIQUID PROPANE OUTDOOR NATURAL GAS OUTDOOR LIQUID PROPANE

Model Number RTGH-CM95DVLN RTGH-CM95DVLP RTGH-CM95XLN RTGH-CM95XLP

Quantity Needed

Rheem Commercial Tankless Water Heaters

Controls included

Condensate neutralizer included

Communication cables included

Isolation and pressure relief valves included

✓ ✓

✓ ✓

Page 2: Rheem Commercial Tankless Water Heater …...Rheem® Commercial Tankless Water Heater Submittal Sheet L L L Commercial Tankless Models System: RTR = Rheem Tankless Rack Will contain

2

QTY. MODEL NUMBER

NUMBER OF UNITS

SYSTEMDESCRIPTION

FUEL TYPE LAYOUT

RTR-FS411DVLN 2-Units Indoor Free Standing Nat. Gas

RTR-FS411XLN 2-Units Outdoor Free Standing Nat. Gas

RTR-FS411XVLP 2-Units Outdoor Free Standing LP Gas

RTR-FS420DVLN 2-Units Indoor Free Standing Nat. Gas

RTR-FS420XLN 2-Units Outdoor Free Standing Nat. Gas

RTR-FS420XLP 2-Units Outdoor Free Standing LP Gas

RTR-FS630DVLN 3-Units Indoor Free Standing Nat. Gas

RTR-FS630XLN 3-Units Outdoor Free Standing Nat. Gas

RTR-FS630XLP 3-Units Outdoor Free Standing LP Gas

RTR-FS421DVLN 3-Units Indoor Free Standing Nat. Gas

RTR-FS421XLN 3-Units Outdoor Free Standing Nat. Gas

RTR-FS421XLP 3-Units Outdoor Free Standing LP Gas

RTR-FS422DVLN 4-Units Indoor Free Standing Nat. Gas

RTR-FS422XLN 4-Units Outdoor Free Standing Nat. Gas

RTR-FS422XLP 4-Units Outdoor Free Standing LP Gas

RTR-FS632DVLN 5-Units Indoor Free Standing Nat. Gas

RTR-FS632XLN 5-Units Outdoor Free Standing Nat. Gas

RTR-FS632XLP 5-Units Outdoor Free Standing LP Gas

RTR-FS633DVLN 6-Units Indoor Free Standing Nat. Gas

RTR-FS633XLN 6-Units Outdoor Free Standing Nat. Gas

RTR-FS633XLP 6-Units Outdoor Free Standing LP Gas

Freestanding Tankless Rack SystemMounts to ground only, must be on the ground, can be any distance from the wall.

RHEEM COMMERCIAL TANKLESS SYSTEMS SUBMITTAL

Page 3: Rheem Commercial Tankless Water Heater …...Rheem® Commercial Tankless Water Heater Submittal Sheet L L L Commercial Tankless Models System: RTR = Rheem Tankless Rack Will contain

3

QTY. MODEL NUMBER

NUMBER OF UNITS

SYSTEMDESCRIPTION

FUEL TYPE LAYOUT

RTR-WH220DVLN 2-Units Indoor Wall Hanging Nat. Gas

RTR-WH220XLN 2-UnitsOutdoor

Wall HangingNat. Gas

RTR-WH220DVLP 2-Units Indoor Wall Hanging LP Gas

RTR-WH220XLP 2-UnitsOutdoor

Wall HangingLP Gas

RTR-WH330DVLN 3-Units Indoor Wall Hanging Nat. Gas

RTR-WH330XLN 3-UnitsOutdoor

Wall HangingNat. Gas

RTR-WH330DVLP 3-Units Indoor Wall Hanging LP Gas

RTR-WH330XLP 3-UnitsOutdoor

Wall HangingLP Gas

QTY. MODEL NUMBER

NUMBER OF UNITS

SYSTEMDESCRIPTION

FUEL TYPE LAYOUT

RTR-WM220DVLN 2-UnitsIndoor

Wall MountNat. Gas

RTR-WM220XLN 2-UnitsOutdoor

Wall MountNat. Gas

RTR-WM220DVLP 2-UnitsIndoor

Wall MountLP Gas

RTR-WM220XLP 2-UnitsOutdoor

Wall MountLP Gas

RTR-WM330DVLN 3-UnitsIndoor

Wall MountNat. Gas

RTR-WM330XLN 3-UnitsOutdoor

Wall MountNat. Gas

RTR-WM330DVLP 3-UnitsIndoor

Wall MountLP Gas

RTR-WM330XLP 3-UnitsOutdoor

Wall MountLP Gas

Wall Hanging Tankless SystemMounts to wall only, can hang any distance above the ground.

Wall Mount Tankless SystemMounts to wall and ground, must be on the ground, and against the wall.

RHEEM COMMERCIAL TANKLESS SYSTEMS SUBMITTAL

NOTES

Page 4: Rheem Commercial Tankless Water Heater …...Rheem® Commercial Tankless Water Heater Submittal Sheet L L L Commercial Tankless Models System: RTR = Rheem Tankless Rack Will contain

4

RHEEM COMMERCIAL TANKLESS SYSTEMS SUBMITTAL

Back to Back Common Venting

Inline Common Venting

QTY. DIRECT VENT PART N0. QTY. ROOM AIR

PART N0.TRUNK DIAM.

NO. OF UNITS

SP20912A SP20913A

6"

2

SP20912B SP20913B 3

SP20912C SP20913C 4

SP20914A SP20915A

8"

2

SP20914B SP20915B 3

SP20914C SP20915C 4

SP20914D SP20915D 5

SP20914E SP20915E 6

SP20914F SP20915F 7

SP20914G SP20915G 8

SP20916A SP20917A

10"

2

SP20916B SP20917B 3

SP20916C SP20917C 4

SP20916D SP20917D 5

SP20916E SP20917E 6

SP20916F SP20917F 7

SP20916G SP20917G 8

Diagrams illustrate horizontal intake and exhaust, vertical intake and exhaust also available, but not pictured.

Wall3 Degree upwardslope toward outside

To suitable drain

12” - 24” (31 cm – 61 cm)

Min 36”(91cm)

Max 20’(6.1m)

20.5”(52 cm)

Max. vent length distance (header kits not counted towards max vent length)

Intake trunk pieces not included in ROOM AIR kits.

Intake trunk pieces not included in ROOM AIR kits.

Back to Back Venting Gas Chip

QTY. DIRECT VENT PART N0. QTY. ROOM AIR

PART N0.TRUNK DIAM.

N0. OF UNITS

SP20906A SP20907A

6"

2

SP20906B SP20907B 3

SP20906C SP20907C 4

SP20908A SP20909A

8"

2

SP20908B SP20909B 3

SP20908C SP20909C 4

SP20908D SP20909D 5

SP20908E SP20909E 6

SP20908F SP20909F 7

SP20908G SP20909G 8

SP20910A SP20911A

10"

2

SP20910B SP20911B 3

SP20910C SP20911C 4

SP20910D SP20911D 5

SP20910E SP20911E 6

SP20910F SP20911F 7

SP20910G SP20911G 8

SP20910H SP20911H 9

SP20910J SP20911J 10

Wall 3 Degree upwardslope toward outside

To suitable drain

12” - 24” (31 cm – 61 cm)

Min 36”(91cm)

Max 20’(6.1m)

20.5”(52 cm)

SCALE 1.000

Max. vent length distance (header kits not counted towards max vent length)

Diagrams illustrate horizontal intake and exhaust, vertical intake and exhaust also available, but not pictured.

ADDITONAL ACCESSORIES

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com

PRINTED IN U.S.A. 09/18 WP FORM NO. TK-RTR-SUBMIT