Please read this manual before use
Cinda
Typewritten Text
TALKING EAR AND FOREHEAD THERMOMETER
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
INSTRUCTION MANUAL MODEL: DX6635
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Page 2: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent
Page 3: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

- Thank you for purchasing our DX6635 Talking Multi-Functional Ear and Forehead thermometer. For a desirable use of this product, be sure to read this user manual before use.- Firstly, open the battery case and gently pull out the plastic safety tab. The thermometer will not activate until the tab has been removed.- For safe and proper use of this product, be sure to read and fuIly understand Safety Precautions steps outlined in this user manual.- Keep this manual in a safe and accessible location for easy access and future reference.

INTENDED FOR USE

The device is intended for the intermittent measurement and monitoring of human body temperature by consumers in the home.

SAFETY PRECAUTIONS

- Warning marks and symbols are displayed for your safety and to ensure proper use of this product and prevent any injuries.- See table below for description of warning marks and symbols:

WARNINGMeans a possibility of personal injury in case of improper use.

NOTICEMeans a possibility of personal injury or property damage* in case of improper use.

[*Property damage covers any damage to house,family property, domestic animal.]

MARKS OR SYMBOLS

PROHIBITION

MUST OBSERVE

IMPLICATION OF SYMBOL

Means Forbidden with detailed items expressed in words or figures within or beside the mark. The example here is 'General Forbidden'.

Means Obligatory with detailed items expressed in words or figures within or beside the mark. This example here is 'General compulsory'.

Means Type-B device.

P.1

Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Page 4: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

P.2

Cinda
Typewritten Text
Measurement should be suspended until the ear has adjusted to room temperature.
Cinda
Typewritten Text
Page 5: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

P.3

Page 6: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

FRI

1st of the manufacturing year

P.4

Page 7: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

P.5

Page 8: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

3. Press and hold [ T ] button for 2 seconds to toggle the language which you want or non talking function.

P.6

Page 9: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

P.7

Page 10: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

P.8

Page 11: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

Maintenance:

1. Remove any stains on the body with a soft and dry cloth.

2. Don't wash with water or detergent containing abrasive or benzene.

Storage:

1. Clean the thermometer and use the cover to protect the lens after each use.

2. Don't leave the thermometer exposed to or at high risk of direct sunlight, high temperature, dampness, fire, flame, vibration or impact.

3. Remove the battery if the device will not be used for a long period of time.

Calibration:

This thermometer is calibrated at the time of manufactured. If the

thermometer is used according to the instructions, periodic recalibration is not

required. If at any time you question the accuracy of the measurement, please

contact the retailer immediately.

Don't attempt to modify or reassemble the thermometer.

MAINTENANCE, STORAGE AND CALIBRATION

TROUBLES AND TROUBLESHOOTING

Troubles

Battery symbol on LCD

Check lists Countermeasures

“Lo” on screen (result below 32.0℃ or 89.6℉)

“Hi” on screen (result below 42.9℃ or 109.3℉)

No response/Automaticreset when pull out insulator

Low battery power

Battery in wrong polarity

Poor battery contact

Change battery

Take out battery, reinsert battery correctly

Low battery Change new battery

Thermometer rightly pointedat the eardrum / forehead?

Follow user’s manual to point at the eardrum /forehead.

Please check the operationmethod

Follow user’s manual forproper measurement.

P.9

Page 12: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

Product Name: Talking Multi-Functional Ear and Forehead thermometer

Model: DX6635Power supply: DC3V (2 x AAA battery)Power consumption: <30mA (for voice prompt)Temperature sensing Part: IR sensor

Measuring range: 32.0℃ ~ 42.9℃ (89.6℉ ~109.3℉)

Room Temperature: 5.0℃ ~ 59.9℃ (41.0℉ ~139.8℉)

Measuring accuracy: +/- 0.2℃ (or +/- 0.4℉)

from 35.5℃ ~ 42.0℃ (or 95.9℉ ~107.6℉)

+/- 0.3℃ (+/- 0.5℉)

from 35.0℃ ~ 35.4℃ (or 89.6℉ ~ 95.8℉)

from 41.2℃ ~ 42.9℃ (or 107.7℉ ~ 109.3℉)

Room Temperature: +/- 1℃ (2℉)

Outer dimension: 130(L)x41(W)X57(D)mmWeight : 54g (without batteries)

Working environment: 10℃~ 40℃ (50.0℉~104.0℉) For Ear

15℃~40℃ (59.0℉~104.0℉) For Forehead

Relative humidity: 20%RH~85%RH

Storage environment: -10℃~ 55℃ (14℉~131℉)

Relative humidity: 20%RH~85%RH

Precision/repeatability: +/- 0.3℃ (+/- 0.5℉)

*Dispose of used batteries with care consult your distribution center for details.

.

.

SPECIFICATION

P.10

Page 13: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

0197

SYMBOLS

Batch code

Serial number

Attention: Read the operating instructions before use !

Applied part of type B

Disposal in accordance with Directive 2002/96/EC (WEEE)

LOT

SN

Complies with the European Medical Device Directive

(93/42/EEC) and amended by directive 2007/47/EC

requirements. Notified body TÜV Rheinland (CE0197)

The name and the address of the manufacturer

P.11

Page 14: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

GUIDANCE AND MAUFACTURER'S DECLARATION

Emissions test Compliance Electromagnetic environment - guidance-

RF emissions CISPR 11

Group2 The device must emit electromagnetic e energy in order to perform its intended function. Nearby electronic equipment maybe affected.

RF emissionsCISPR11

Class B

HarmonicemissionslEC 61000-3-2

Not applicable

Not applicable

RF emissionsCISPR 14-1

Complies

RF emissionsCISPR 15

Complies

The device is intended for use in the electromagnetic environment specified

below. The customer or the user assures that it is used in such an environment.

Guidance and manufacturer's declaration - electromagnetic emissions

The device is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply networkthat supplies buildings used for domestic purposes. Voltage

fluctuations / flicker emissions lEC 61000-3-3

The device is not suitable forinterconnection with other equipment.

The device is not suitable for interconnection with other equipment.

P.12

Page 15: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

Immunity test IEC 60601test level

Compliance level

Electrostatic discharge (ESD) lEC 61000-4-2

±6 kV contact±8 kV air

Electrical fasttransient/burstIEC 61000-4-4

±2kV for power supply lines±1kV for input/output lines

±1kV differential mode±2kVcommon mode

Voltage dips, short interruptions and voltagevariations on power supply input linesIEC 61000-4-11

The device is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment.

Guidance and manufacturer's declaration — electromagnetic immunity

SurgeIEC 61000-4-5

Electromagnetic environment - guidance

±6 kV contact±8 kV air

Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.

Not applicable

Mains power qualityshould be that of a typicalcommercial or hospitalenvironment.

Not applicable

Mains power qualityshould be that of a typicalcommercial or hospitalenvironment.

<5% UT(>95% dip in UT) for 0.5 cycle40% UT(60% dip in UT) for 5 Cycles70% UT(30% dip in UT) for 25 Cycles<5% UT(>95% dip in UT) for 5 sec

Mains power quality should be that of a typical commercial or hospitalenvironment. If the userof the device requires continued operation during power mains interruptions, it is recommended that the device is powered from an uninterruptible power supply or a battery.

Not applicable

Power frequency(50/60Hz)magnetic fieldIEC 61000-4-8

3 A/m 3 A/m

Power frequency magneticfields should be at levelscharacteristic of a typicallocation in a typical commercial or hospital environment.

NOTE: UT is the a.c. mains voltage prior to application of the test level.

P.13

Page 16: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

The device is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment.

Guidance and- manufacturer's declaration. Electromagnetic immunity

Conducted RF lEC 61000-4-6

Portable and mobile RF Communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from theequation applicable to the frequency ofthe transmitter. Recommended separation distance.

3 V

3 V/m

NOTE I At 80 MHz ends 800 MHz. the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

3 Vrms150 kHz to80 MHz

Radiated RF lEC 61000-4-3

3 V/m80 MHz to 2.5 GHz

80 MHz to 800 MHz

800 MHz to 2.5 GHz

Where P is the maximum output power rating of the transmitter In watts (W) according to the. Transmitter manufacturer and d is the recommendedseparation distance in meters (m). Field strengths from fixed RFtransmitters, as determined by an electromagnetic site survey,a should beless than the compliance level in each frequency range.Interference may occur in thevicinity of equipment marked with the following symbol:

a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To

d=[ ] p3.5V1

d=[ ] p3.5E1

d=[ ] p7E1

P.14

Page 17: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measuredfield strength in the location in which the device is used exceeds the applicable RF compliance level above, should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the device.b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [Vi] V/m.

Recommended separation distances between portable and mobile RF communications equipment and the device

Ratedmaximumtransmitter

output power of

W

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) accordable to thetransmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz. the separation distance for the higher frequency range applies.

150 kHz to 80 MHz

0,01

The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the userof the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the as recommended below, according to the maximum output power of the communications equipment.

Separation distance according to frequency of transmitter

150 kHz to 80 MHz 150 kHz to 80 MHz

0.12 0.12 0.23

0,1 0.38 0.38 0.73

1 1.2 1.2 2.3

10 3.8 3.8 7.3

100 12 12 23

d=[ ] p3.5V1

d=[ ] p3.5E1

d=[ ] p7E1

P.15

Page 18: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

DECLARATION OF CONFORMITY

Shenzhen Dongdixin Technology Co., LTD declares that the DX6635

complies with following normative documents:

IEC60601-1, IEC60601-1-2, IEC60601-1-4, ASTM E1965-98,

ISO10993-5, ISO10993-10, ISO10993-1,ISO 14971,EN 12470-5.

NOTE 2 These guidelines may not apply in all situations. Electromagneticpropagation is affected by absorption and reflection from structures, objects and people.For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) accordable to the transmittermanufacturer. NOTE 3 At 80 MHz and 800 MHz. the separation distance for the higher frequency range applies. NOTE 4 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

WARRANTY

Two-year warranty is available from purchasing date, excluding user-caused

failures listed below:

(1) Failure resulted in unauthorized disassembly and modification

(2) Failure resulted in unexpected drop during application or transportation

(3) Failure resulted in operation away from proper instruction in user’s manual.

Present the Warranty Card with seal of distribution center (incI. name and

address) for repair free.

P.16

Page 19: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent
Page 20: rMODEL: DX6635omegamed.com.au/content/uploads/2014/01/DX-6635-manual.pdf · Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent

Manufacturer:Name: Shenzhen Dongdixin Technology Co., LTD.Add: No.3 Building XiliBaimang Xusheng Industrial Estate, 518108 Nanshan, Shenzhen China

Copyright 2011 by Shenzhen Dongdixin Technology Co., LTD.Edition: V1.2Printed in 2011

Authorized EC-representative: Shanghai International Holding Corp. GmbH (Europe)Eiffestraße 80, 20537 Hamburg Germany

0197

NOTES:1) Under the environment with electrostatic discharge, the unit may malfunction and may require user to reset the unit.2) Dispose with care, please consult the retailer for details.

Cinda
Typewritten Text
Distributed by: Omega Medical Instruments Pty Ltd Suite 8, Level 12 101 Bathurst Street NSW 2000 AUSTRALIA
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text
Cinda
Typewritten Text