20
NETWORK CONVERTER 대응 NETC01-CC RoHS지령 적합품 Network Converter NETC01-CC는 CC-Link 통신과 RS-485 통신의 통신 Protocol 변환기입니다. NETC01-CC를 사용해 CC-Link 통신 환경에서 당사의 RS-485 대응 제품을 제어할 수 있습니다.

RoHS지령 적합품 NETWORK CONVERTER 대응

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Network Converter NETC01-CC CC-Link RS-485 Protocol .
NETC01-CC CC-Link RS-485 .
2
RS-485 CC-Link .
CONTROLLER(MASTER)
CC-Link
RS-485
NETWORK CONVERTER CC-Link .
Network Converter NETC01-CC CC-Link RS-485 Protocol .
NETC01-CC CC-Link RS-485 .
NETC01-CC CC-Link Data OPX2A()
. Data Scan Time Monitor
. Data → 19 Page
3
6 12 .
DEVICE 6 MODE 12 MODE
REMOTE I/O RXn 1 16 1 8
RYn 1 16 1 8
REMOTE REGISTER
.
Network Converter, RS-485 Cable, Connector, CC-Link Connector,

.
Compact Size.
NETWORK
,
.
DIN RAIL
Cable
RS-485
NETC01-CC RS-485 Protocol . .

• DC24V
• Controller
• Data 63 Point ,
User I/O Data .
•Motor Driver Set Unit . CRK Series

TYPE
RoHS .
·CE MARKING
EMISSION EN 61000-6-4 EN 55011
IMMUNITY EN 61000-6-2 IEC 61000-4-3 IEC 61000-4-2 IEC 61000-4-4 IEC 61000-4-6
EMC ·
.
4
Field Network System CC-Link . CC-Link .
STEPPING MOTOR UNIT AS Series CC-Link
• Closed Loop Stepping Motor Unit.
• Data 63 Point ,
User I/O Data .
• Torque, Motor Variation .
•Motor Driver .
SLIDER CONTROLLER CC-Link
• Slider Cylinder CC-Link
Controller.
•Actuator Controller .
.
BRUSHLESS MOTOR UNIT BLE Series CC-Link
•80~4000r/min
Brushless Motor Unit.
.
• Timing User I/O
.
CC-Link
CC-Link
CC-Link Ver.1.10

1×a+(2×b+(3×c+(4×d64 a1 Unit b2 Unit c3 Unit d4 Unit
16×A+(54×B+(88×C2304 ARemote I/O (64 ) BRemote Device (42 ) CLocal (26 )
CABLE CC-Link Cable
CABLE
Cable 0.2m
Cable 1200m 900m 400m 160m 100m
RS-485
EIA-485 Twist pair(TIA/EIA-568B CAT5e ) , Cable 50m .

PROTOCOL 9 Byte Frame, Binary
6 12( Mode )

DC500V Mega 100MΩ . •FG -
AC500V 50/60Hz 1 . •FG -
()
85% ( )
1000m
· . .
(·)
85% ( )
3000m
· . .

6
1 0 0
http://www.inaom.co.kr

• Connector
7
RS-485 CONNECTOR
MODE SWITCH
POWER POWER LED
ALARM ALARM LED . Alarm . 0.2, 1.4.
C-DAT C-DAT LED RS-485
C-ERR C-ERR LED RS-485
L-RUN L-RUN LED CC-Link
L-ERR L-ERR LED CC-Link
SD SD LED CC-Link Data
RD RD LED CC-Link Data
RS-485 SWITCH(SW1)
SW1
0 9,600 bps
1 19,200 bps
2 38,400 bps
3 57,600 bps
4 115,200 bps
5 250,000 bps
6 312,500 bps
7 625,000 bps
8~F 8 Switch Alarm .
SW1 .
SW1 .
CONNECTOR(CN1)
STATION No.×10
7~9
0~9 1
01~64 . CC-Link 2 . 00 .
CC-Link BAUD RATE SWITCH(B-RATE)
B-RATE
OFF 6 MODE
NETC01-CC 1 RS-485 6 . RS-485 1 Remote I/O 16.
ON 12 MODE
NETC01-CC1 RS-485 12 . RS-485 1 Remote I/O 8.
2
3
4
Mode SW2 . SW2 Mode .
CC-Link CONNECTOR(CN2)
5 FG Frame Ground
PIN
1 RS-485 (120) OFF ON
RS-485 CONNECTOR(CN6)
2 GND GND
REMOTE I/O
6 Mode/12 Mode Remote I/O . n Master Address.
6 MODE REMOTE I/O
RY(MASTER NETC01-CC) RX(NETC01-CC MASTER)
DEVICE No. 8bit 8bit DEVICE No. 8bit 8bit
RYnFRYn0 0 RXnFRXn0 0
RY n+1FRY n+10 1 RX n+1FRX n+10 1
RY n+2FRY n+20 2 RX n+2FRX n+20 2
RY n+3FRY n+30 3 RX n+3FRX n+30 3
RY n+4FRY n+40 4 RX n+4FRX n+40 4
RY n+5FRY n+50 5 RX n+5FRX n+50 5
RY n+6FRY n+60 NETC01-CC RX n+6FRX n+60 NETC01-CC
RY n+7FRY n+70 System RX n+7FRX n+70 System
12 MODE REMOTE I/O
RY(MASTER NETC01-CC) RX(NETC01-CC MASTER)
DEVICE No. 8bit 8bit DEVICE No. 8bit 8bit
RYnFRYn0 1 0 RXnFRXn0 1 0
RY n+1FRY n+10 3 2 RX n+1FRX n+10 3 2
RY n+2FRY n+20 5 4 RX n+2FRX n+20 5 4
RY n+3FRY n+30 7 6 RX n+3FRX n+30 7 6
RY n+4FRY n+40 9 8 RX n+4FRX n+40 9 8
RY n+5FRY n+50 11 10 RX n+5FRX n+50 11 10
RY n+6FRY n+60 NETC01-CC RX n+6FRX n+60 NETC01-CC
RY n+7FRY n+70 System RX n+7FRX n+70 System
9
Remote Register . 6 Mode/12 Mode .
Remote Register RS-485 NETC01-CC Monitor, Parameter /, Maintenance Command .
RWw MASTER NETC01-CC) RWr NETC01-CC MASTER)
ADDRESS No. ADDRESS No.
RWwn0 Monitor0 Command RWrn0 Monitor0 Data()
RWwn1 Monitor0 RWrn1 Monitor0 Data()
RWwn2 Monitor1 Command RWrn2 Monitor1 Data()
RWwn3 Monitor1 RWrn3 Monitor1 Data()
RWwn4 Monitor2 Command RWrn4 Monitor2 Data()
RWwn5 Monitor2 RWrn5 Monitor2 Data()
RWwn6 Monitor3 Command RWrn6 Monitor3 Data()
RWwn7 Monitor3 RWrn7 Monitor3 Data()
RWwn8 Monitor4 Command RWrn8 Monitor4 Data()
RWwn9 Monitor4 RWrn9 Monitor4 Data()
RWwnA Monitor5 Command RWrnA Monitor5 Data()
RWwnB Monitor5 RWrnB Monitor5 Data()
RWwnC Command RWrnC Command
RWwnD RWrnD
RWwnE Data() RWrnE Data()
RWwnF Data() RWrnF Data()
DEVICE No. DEVICE No.
RY n+60 Monitor 0 M-REQ0 RX n+60 Monitor0 M-DAT0
RY n+61 Monitor 1 M-REQ1 RX n+61 Monitor1 M-DAT1
RY n+62 Monitor 2 M-REQ2 RX n+62 Monitor2 M-DAT2
RY n+63 Monitor 3 M-REQ3 RX n+63 Monitor3 M-DAT3
RY n+64 Monitor 4 M-REQ4 RX n+64 Monitor4 M-DAT4
RY n+65 Monitor 5 M-REQ5 RX n+65 Monitor5 M-DAT5
RY n+66 RX n+66 Warning WNG
RY n+67 Alarm Reset ALM-RST RX n+67 Alarm ALM
RY n+68 RX n+68 RS-485 C-SUC
RY n+69 RX n+69
RY n+6A RX n+6A
RY n+6B RX n+6B
RY n+6C Command D-REQ RX n+6C Command D-END
RY n+6D RX n+6D Register Error R-ERR
RY n+6E RX n+6E System S-BSY
RY n+6F RX n+6F
SYSTEM REMOTE I/O
RY MASTER NETC01-CC) RX NETC01-CC MASTER)
DEVICE No. DEVICE No.
RY n+70
RY n+71 RX n+71
RY n+72 RX n+72
RY n+73 RX n+73
RY n+74 RX n+74
RY n+75 RX n+75
RY n+76 RX n+76
RY n+77 RX n+77
RY n+78 RX n+78
RY n+79 RX n+79
RY n+7A RX n+7A
RY n+7B RX n+7B Remote Ready CRD
RY n+7C RX n+7C
RY n+7D RX n+7D
RY n+7E RX n+7E
RY n+7F RX n+7F
10
RYn
D-REQ Command Remote Register Parameter Command Maintenance Command . D-REQ ON Edge Command .
ALM-RST Alarm Reset NETC01-CC Alarm ALM Bit ON . ALM-RST ON OFF Alarm ALM Bit OFF .
M-REQ0M-REQ5 Monitor Monitor . M-REQk(k:Monitor 0~5) ON Monitor . 1Monitor (Monitor ) 0Monitor (Monitor )
RX(NETC01-CC MASTER)
RXn
S-BSY System Parameter R/W Command Maintenance Command . 1Command 0Command
R-ERR Register Error
Parameter Command, Monitor Command, Maintenance Command Error ON . Error (M-REQn D-REQ) OFF R-ERR OFF . Error Error Code Remote Register . 1Error 0Error
D-END Command Parameter Command Maintenance Command ON . D-REQ OFF D-END OFF . Parameter Command Maintenance Command Error D-END ON , R-ERR ON .
C-SUC RS-485 RS-485 . 1RS-485 0RS-485 Error .
ALM Alarm NETC01-CC Alarm . 1Alarm 0Alarm
WNG Warning NETC01-CC Warning . Warning WNG OFF . 1Warning 0Warning
M-DAT0M-DAT5 Monitor Monitor (M-REQn) ON Monitor . 1Monitor 0Monitor Error Monitor .
SYSTEM REMOTE I/O

RXn CRD Remote Ready CC-Link ON .
11
NETC01-CC Parameter / CC-Link Parameter Command Data OPX-2A() .
CC-Link Parameter Command Parameter NETC01-CC RAM . Parameter
.
APPLICATION PARAMETER CODE

0CC4h 1CC4h Data Data / .
0 1
SYSTEM PARAMETER CODE

0D80h 1D80h 0 0 .
0
CRD507-KD CRD514-KD
2
0D81h 1D81h 1 1 .
0 SYS-4-01
0D82h 1D82h 2 2 .
0 SYS-4-02
0D83h 1D83h 3 3 .
0 SYS-4-03
0D84h 1D84h 4 4 .
0 SYS-4-04
0D85h 1D85h 5 5 .
0 SYS-4-05
0D86h 1D86h 6 6 .
0 SYS-4-06
0D87h 1D87h 7 7 .
0 SYS-4-07
0D88h 1D88h 8 8 .
0 SYS-4-08
0D89h 1D89h 9 9 .
0 SYS-4-09
0D8Ah 1D8Ah 10 10 .
0 SYS-4-10
0D8Bh 1D8Bh 11 11 .
0 SYS-4-11
System Parameter . System Parameter Maintenance Command NV Memory
.
12
2E00h Alarm Alarm Code .
2E01h Alarm 1 Alarm 1 Code .
2E02h Alarm 2 Alarm 2 Code .
2E03h Alarm 3 Alarm 3 Code .
2E04h Alarm 4 Alarm 4 Code .
2E05h Alarm 5 Alarm 5 Code .
2E06h Alarm 6 Alarm 6 Code .
2E07h Alarm 7 Alarm 7 Code .
2E08h Alarm 8 Alarm 8 Code .
2E09h Alarm 9 Alarm 9 Code .
2E0Ah Alarm 10 Alarm 10 Code .
2E0Bh Warning Warning Code .
2E0Ch Warning 1 Warning 1 Code .
2E0Dh Warning 2 Warning 2 Code .
2E0Eh Warning 3 Warning 3 Code .
2E0Fh Warning 4 Warning 4 Code .
2E10h Warning 5 Warning 5 Code .
2E11h Warning 6 Warning 6 Code .
2E12h Warning 7 Warning 7 Code .
2E13h Warning 8 Warning 8 Code .
2E14h Warning 9 Warning 9 Code .
2E15h Warning 10 Warning 10 Code .
2E31h Error Code(Monitor0 Monitor 0 Error Code .
2E32h Error Code(Monitor1 Monitor 1 Error Code .
2E33h Error Code(Monitor2 Monitor 2 Error Code .
2E34h Error Code(Monitor3 Monitor 3 Error Code .
2E35h Error Code(Monitor4 Monitor 4 Error Code .
2E36h Error Code(Monitor5 Monitor 5 Error Code .
2E37h Error Code (Parameter R/W, Maintenance)
Parameter R/W, Maintenance Error Code .
2E3Ah RS-485 Status RS-485 Status .
2E3Bh RS-485 Scan Time RS-485 . Data [0.1ms] .
13
CODE
3E81h Alarm Clear Alarm Clear.
3E82h Warning Clear Warning Clear.
3E84h NV Memory NV Memory Parameter .
3E85h NV Memory NV Memory Parameter .
3E86h Parameter NETC01-CC Parameter .

ON(1) . Alarm ALARM LED .
ALARM LED Alarm .
Data OPX-2A CC-Link Monitor Command
Alarm . Alarm RS-485
.
200ms
1.4s

CODE ALM LED
21h 2 NETC01-CC 85°C .
Case .
Data OPX-2A Maintenance Command Parameter .

NETC01-CC RS-485 CC-Link .
CC-Link Connector Cable .

83h 7 Switch SW1(RS-485 Switch)
SW1 0~7 .

84h 7 RS-485 RS-485 3 .
. RS-485 Connector , Cable .

86h 7 Network Parameter .
Parameter .

CODE
84h RS-485 RS-485 . . RS-485 Connector , Cable .
85h RS-485 Time Out RS-485 Response Frame .
RS-485 Connector , Cable . RS-485 .
WARNING Data OPX-2A 10 Warning Warning .
Warning NETC01-CC .
Warning , Warning Warning Warning .
14
CRK Series NETC01-CC Remote I/O .
n CC-Link Master Address.
m, j CRK Series Controller Type Address.
m j m j m j
0 0 0
4 4 2
8 8 4
2 2 1
6 6 3
10 10 5
CRK Series TYPE REMOTE I/O (6 MODE)
RY(MASTER NETC01-CC) RX NETC01-CC MASTER)
DEVICE No. DEVICE No.
RY n+m0
Data
RY n+m1 M1 RX n+m1 M1_R
RY n+m2 M2 RX n+m2 M2_R
RY n+m3 M3 RX n+m3 M3_R
RY n+m4 M4 RX n+m4 M4_R
RY n+m5 M5 RX n+m5 M5_R
RY n+m6 RX n+m6 Warning WNG
RY n+m7 RX n+m7 Alarm ALM
RY n+m8 START RX n+m8 START_R
RY n+m9 (+) FWD RX n+m9 STEP OUT
RY n+mA (-) RVS RX n+mA MOVE
RY n+mB HOME RX n+mB HOME-P
RY n+mC STOP RX n+mC
RY n+mD Motor / CON RX n+mD READY
RY n+mE RX n+mE
RY n+mF RX n+mF Area AREA
CRK Series TYPE REMOTE I/O (12 MODE)
RY(MASTER NETC01-CC) RX NETC01-CC MASTER)
DEVICE No. DEVICE No.
RY n+j0 RY n+j8
START RX n+j0 RX n+j8
START_R
RY n+j1 RY n+j9
(+) FWD RX n+j1 RX n+j9
STEP OUT
(-) RVS RX n+j2 RX n+jA
MOVE
RY n+j3 RY n+jB
HOME RX n+j3 RX n+jB
HOME-P
RY n+j4 RY n+jC
STOP RX n+j4 RX n+jC
Alarm ALM
RY n+j5 RY n+jD
Motor / CON RX n+j5 RX n+jD
READY

Area AREA

NETC01-CC)
CON Motor ON Motor ON/OFF . 1:Motor ON 0:Motor OFF
STOP // . 1: 0: Parameter Command STOP ( Code 0C02h) .
HOME . HOME Bit ON Edge .
RVS (-) - . 1: 0: , FWD/RVS Bit ON .
FWD (+) + . 1: 0: , FWD/RVS Bit ON .
START . START Bit ON Edge .
M0~M5 Data Data No. .
RXn NETC01-CC
MASTER)
AREA Area Motor Area . 1: Area 0:Area
READY . READY ON . READY OFF . 1: 0:
HOME-P /
. 1: 0:
MOVE . MOVE ON . 1: 0 :
STEPOUT . 1: 0 :
START_R RYn START . 1:START ON 0:START OFF
ALM Alarm Alarm . 1: Alarm 0:Alarm
WNG Warning Warning . Warning WNG OFF. 1:Warning 0:Warning
M0_R~ M5_R
Data Data No. .
CRK Series TYPE CODE
DATA CODE


1
0: 1:
1
1
0C06h 1C06h OUT1 5AREA, 6TIM, 7READY, 5
0C07h 1C07h OUT2 8WNG, 9HOME-P, 10ZSG, 7
0C08h 1C08h OUT3 11R-OUT1, 12R-OUT2, 8
0C09h 1C09h OUT4 13STEP OUT 9
0C0Ah 1C0Ah HOME/P-PRESET 0HOME 1P-PRESET
0
1
1
1
0
1
0
0
0
0
0C1Ah 1C1Ah ENCODER COUNTER PRESET -8,388,6088,388,607step 0
0C20h 1C20h 5100% 100
0C21h 1C21h 550% 50
0C40h 1C40h RATE 11,000,0000.001ms/kHz 30,000
0C41h 1C41h RATE 11,000,0000.001ms/kHz 30,000
0C42h 1C42h 1500,000Hz 100
0C46h 1C46h JOG 1500,000Hz 1,000
0C47h 1C47h JOG RATE 11,000,0000.001ms/kHz 30,000
0C48h 1C48h JOG 1500,000Hz 100
17

0
0C60h 1C60h 0: 2 Sensor 1: 3 Sensor
1
0C63h 1C63h RATE 11,000,000 0.001ms/kHz 30,000
0C64h 1C64h 1500,000Hz 100
0C65h 1C65h OFFSET -8,388,6088,388,607step 0
0C66h 1C66h 0:- 1:+
1
0
0
032,767step 200
0CC0h 1CC0h SOFTWARE OVER TROUBLE
0: 1:
0CC3h 1CC3h DATA
0: 1:
1
1
0CC7h 1CC7h RS-485 0 19990.01s
0
0CC9h 1CC9h RS-485 19990.01s 10
0CCAh 1CCAh 0: (Alarm,Warning ) 1: Warning 2: Alarm
0
CODE

0D0Ah 1D0Ah MOTOR 0:+=CCW 1:+=CW
1
0
0D0Eh 1D0Eh ENCODER GEAR A 1250,000 500
0D0Fh 1D0Fh ENCODER GEAR B 1250,000 500
System Parameter . System Parameter Maintenance Command NV Memory
.
18
CODE
2E16h DATA No. Data No. .
2E17h DATA No. Data No. .
2E18h [step] Counter .
2E1Ah [Hz] .
2E1Bh ENCODER COUNTER Encoder Counter .
2E1Fh I/O STATUS Driver I/O .
2E21h ERROR CODE Error Code . Error Error Code Clear .
2E30h DRIVER STATUS Driver Status .
Warning , Error Code Clear.
CRK Series TYPE MAINTENANCE CODE
Maintenance Command Data = 1 .
CODE
3E84h NV MEMORY NV Memory Parameter .
3E85h NV MEMORY NV Memory Parameter .
3E86h PARAMETER Parameter .
3E88h PRESET Preset(Parameter) .
3E89h ERROR CODE CLEAR Error Code Clear.
3E8Ah ENCODER COUNTER PRESET Encoder Counter Encoder Counter Preset(Parameter) .
3E8Bh COUNTER CLEAR Encoder Counter 0 Clear.
NV Memory 10.
CRK Series TYPE CODE
CODE

R-OUT2 R-OUT1
0 OFF OFF
1 OFF ON
2 ON OFF
3 ON ON
0F03h 1F03h GROUP
Group . -1 : (Group ) 0~11:Group . Group () Command . Group 0~31 , NETC01-CC 0~11 .
-1
0F04h 1F04h DATA No. Data No. . 12 Mode Data No. (0C0Dh/1C0Dh) Parameter 0:Remote I/O .
0
19
OPTION()
DATA Monitor Alarm .


92 0 +0.8
6 8 0
2012P-2000 Printed in Korea
. Catalogue . .
Management System ISO9001 Management System ISO14001 . Catalogue . , . , , , ORIENTAL MOTOR . CC-Link .
TEL:(03)6744-0361
FAX:(03)5826-2576