2
REVISION ECO NO. APP'D DATE REVISION TABLE DESCRIPTION FORM REV AC 1 2 3 4 5 6 7 8 A D C B E F 9 10 11 12 13 14 15 16 G K J H L M A D C B E F G K J H L M DR. TITLE SIZE DRAWING NO. APP'D REFERENCE ROSEMOUNT PRODUCT DATA SHEETS FOR PRODUCT SPECIFICATIONS. CAD MAINTAINED, (PRO/E) SCALE 3RD ANGLE SHEET OF ©2015 ROSEMOUNT INC. ROSEMOUNT INC CERTIFIES THESE DRAWINGS ARE IN ACCORDANCE WITH ROSEMOUNT ENGINEERING SPECIFICATIONS. UNIT NOTES IN INCHES [mm]. CLICK HERE .65 [16,5] .65 [16,5] .65 [16,5] .65 [16,5] 1.99 [50.5] 2.52 [64,0] 2.60 [66,0] 3.31 [84,0] 1.50 [38,1] 2.00 [50,8] 1.81 [46,0] 2.52 [64,0] 11/18/18 J.FRIESZ RTC AA NEW RELEASE 2 1 0FB10-7000 11/18/18 J.FRIESZ 11/18/18 J.ARMSTRONG TYPE I DRAWING ROSEMOUNT PROCESS CONN. NTS D ROSEMOUNT HYGIENIC PROCESS CONNECTION ADAPTERS FB-1001 1.5" TRI CLAMP FB-1002 2" TRI CLAMP FB-1010 VARIVENT TYPE F FB-1011 VARIVENT TYPE N 1. G1 THREAD CONNECTION 1. 1. 1. PROCESS CONNECTION ADAPTERS ASSEMBLE TO TRANSMITTERS WITH G1 PROCESS CONNECTION AND ARE COMPATIBLE WITH THE ROSEMOUNT 326P, ROSEMOUNT 326L, AND ROSEMOUNT 327T TRANSMITTERS. 1.

ROSEMOUNT HYGIENIC PROCESS CONNECTION ADAPTERS …

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ROSEMOUNT HYGIENIC PROCESS CONNECTION ADAPTERS …

REVISION ECO NO. APP'D DATE

REVISION TABLE

DESCRIPTION

FOR

M R

EV A

C

1 2 3 4 5 6 7 8

A

D

C

B

E

F

9 10 11 12 13 14 15 16

G

K

J

H

L

M

A

D

C

B

E

F

G

K

J

H

L

MDR.

TITLE

SIZE

DRAWING NO.

APP'DREF

EREN

CE

RO

SEM

OU

NT

PRO

DU

CT

DAT

A SH

EETS

FO

RPR

OD

UC

T SP

ECIF

ICAT

ION

S.

CAD MAINTAINED, (PRO/E)

SCALE3RD ANGLE

SHEET OF

©20

15 R

OSE

MO

UN

T IN

C.

RO

SEM

OU

NT

INC

CER

TIFI

ESTH

ESE

DR

AWIN

GS

ARE

IN

ACC

OR

DAN

CE

WIT

H

RO

SEM

OU

NT

ENG

INEE

RIN

G

SPEC

IFIC

ATIO

NS.

UN

IT N

OTE

S IN

INC

HES

[mm

].

CLI

CK

HER

E

.65[16,5]

.65[16,5] .65

[16,5].65[16,5]

1.99[50.5] 2.52

[64,0]2.60[66,0]

3.31[84,0]

1.50[38,1]

2.00[50,8]

1.81[46,0]

2.52[64,0]

11/18/18J.FRIESZRTCAA

NEW RELEASE

210FB10-700011/18/18J.FRIESZ

11/18/18J.ARMSTRONGTYPE I DRAWING

ROSEMOUNT PROCESS CONN.

NTSD

ROSEMOUNT HYGIENIC PROCESS CONNECTION ADAPTERS

FB-1001

1.5" TRI CLAMP

FB-1002

2" TRI CLAMP

FB-1010

VARIVENT TYPE F

FB-1011

VARIVENT TYPE N

1. G1 THREAD CONNECTION

1.

1.

1.

PROCESS CONNECTION ADAPTERS ASSEMBLE TO TRANSMITTERS WITH G1 PROCESS CONNECTIONAND ARE COMPATIBLE WITH THE ROSEMOUNT 326P, ROSEMOUNT 326L, AND ROSEMOUNT 327T TRANSMITTERS.

1.

Page 2: ROSEMOUNT HYGIENIC PROCESS CONNECTION ADAPTERS …

FOR

M R

EV A

C

1 2 3 4 5 6 7 8

A

D

C

B

E

F

9 10 11 12 13 14 15 16

G

K

J

H

L

M

A

D

C

B

E

F

G

K

J

H

L

MDR.

TITLE

SIZE

DRAWING NO.

APP'D

CAD MAINTAINED, (PRO/E)

SCALE3RD ANGLE

SHEET OF

REF

EREN

CE

RO

SEM

OU

NT

PRO

DU

CT

DAT

A SH

EETS

FO

RPR

OD

UC

T SP

ECIF

ICAT

ION

S.

©20

15 R

OSE

MO

UN

T IN

C.

RO

SEM

OU

NT

INC

CER

TIFI

ESTH

ESE

DR

AWIN

GS

ARE

IN

ACC

OR

DAN

CE

WIT

H

RO

SEM

OU

NT

ENG

INEE

RIN

G

SPEC

IFIC

ATIO

NS.

UN

IT N

OTE

S IN

INC

HES

[mm

].

CLI

CK

HER

E

.65[16,5]

.65[16,5]

.65[16,5] .65

[16,5]

1.91[48,6]1.96

[49,8] 2.20[56,0] 2.70

[68,5] 1.96[49,8]

2.45[62,2]

1.76[44,7]

.39[10,0]

2.00[50,9]

.39[10,0]

2.48[62,9]

.43[11,0] .83

[21,0]

1.70[43,1]

220FB10-700011/18/18J.FRIESZ

11/18/18J.ARMSTRONGTYPE I DRAWING

ROSEMOUNT PROCESS CONN.

NTSD

FB-1020

DIN 11851 DN32

FB-1021 FB-1022 FB-1041 FB-1045

UNIVERSAL ADAPTER RD52DIN 11851 DN40 DIN 11851 DN50 WELD IN ADAPTER

1.1. 1.

1.

ROSEMOUNT HYGIENIC PROCESS CONNECTION ADAPTERS