Upload
daveleycons
View
227
Download
0
Embed Size (px)
Citation preview
8/10/2019 RR-1014-B
1/10
RR-1014-B
R410A
Neoverter III
Single-SplitInverter Series
8/10/2019 RR-1014-B
2/10
Intelligent Fuzzy Logic ControlDaikin Inverter is equipped with FuzzyLogic Control that will calculate the
temperature difference between thereturn air temperature and the settingtemperature. Then, it will feedback tothe microprocessor to maintain yourdesired room temperature by varyingthe compressor speed, thusproviding a very comfortableenvironment.
RoomTemperature
Start
ComfortableTemperature
Traditional Air Conditioner Inverter Air Conditioner
Comparing inverter and conventional air condtioners
Low Starting CurrentOur Inverters are designed to operate
with a soft-start feature. The
compressor motor does not requireto draw high current during start up asit rams up the speed step by step.
This reduces the surge in drawing theelectricity in a sudden.
Running Current
Hours Of Operation
Conventional Air Conditioner
High staring current Frequent on/off cycle
Inverter Air Conditioner
Low starting current Smooth operation
With the advancement of Inverter Technology, DaikinInverter Series provides a higher energy savingcompared with other conventional air conditioners.
The fixed speed compressors will run at 100% of itscapacity and will stop and start automatically tomaintain the desired temperature. An inverter unit willadjust its capacity to maintain a consistenttemperature, therefore:
You save a lot of energy and also money due tolower power consumption
Longer compressor lifespan due to less start andstop cycles
Comfortable environment without temperaturefluctuations
Reach the desired temperature quickly after start up
Wide Capacity RangeDaikin Inverter is equipped with Fuzzy LogicControl to vary the input frequency to controlthe compressor speed according to the roomload requirements. It provides a wide range ofcapacity to suit your extra cooling needs evenin a very hot day.
Greater Energy SavingProvide a significant savings in energyconsumption due to the great efficiency ofInverter DC compressor with the combinationof Daikin Inverter intelligent technologies.
Fast Cooling Ability to provide large capacity afterthe start up will allow Daikin Inverter toquickly cool down the room. Thus,providing a comfortable environment.
RoomTemperature
SetTemperature
StartInverter System
Conventional System
8/10/2019 RR-1014-B
3/10
T Y P E O F
R E F R I G E R A N T
R 4 1 0 A
FLR15/20/25EV1LFLR15/20/25EV1M
Inverter Product Line UpIndoor Model Capacity RangeOutdoor Model
RR15DV1 RK20/25CV1 1.5 - 2.5hp
1.0 - 2.5hp
1.0 - 2.5hp
1.0 - 2.5hp RR10/15DV1 RK20/25CV1
RK10/15FV1 RK20/25CV1
RR10/15DV1 RK20/25CV1
FTK10/15/20/25MV1IFTK10/15/20/25MV1J
FTK10/15/20/25PV1LFTK10/15/20/25PV1M
FDMR10/15/20/25CV1M
FFR10/15CV1
FCR20/25A2V1
P r o
d u c
t L i n e
U p
8/10/2019 RR-1014-B
4/10
I n v e r t e r
W a l l M
o u n t e d
S e r
i e sUp To 50% Energy SavingBy using intelligent controls, compressor running speed is matched with air-conditioningload. This achieves significant savings in energy consumption.
* Comparison between 1.5HP inverter and non-inverter when operating 8 hours per day.* Subject to individual operating condition.* Tested on 16.5m room size, 25 degC set temperature, and high fan speed at outdoor temperature 33 degC DB.
Daily air conditioner usage
Cummulative Power Consumption (Daily) kWh 9.51kWh
9.51kWh x 365 days = 3471.15kWh
3471.15kWh x RM0.334 = RM1159.36 1762.95kWh x RM0.334 = RM588.83
4.83kWh x 365 days = 1762.95kWh
RM0.334
4.83kWh
RM per kWh
RM
Total Power Consumption (Yearly)
Electricity Bill Rate
Yearly Bill
Hours 8 Hours
RM1159.36 - RM588.83 = RM570.53RM %Yearly Savings On Bill
Yearly Saving On Bill
FTK-P Series FTK-M Series
Cummulative Money Saving In Days* Comparison between 1.5hp Inverter and Non-Inverter when operating 8 hours a day.
* Subject to individual operating conditions.
Ion-Plasma * Only for FTK-M SeriesPurify The Air> effectively deactivated the
bacteria by damaging microbial DNA andsurface structures without being harmfulto human tissues.
Cleanse The Air> Extra negative ions produced by
can remove airborne contaminates fromthe air we breathe and bring the airfabulously fresh and clean.
Outstanding Ranking in The WorldDaikin Inverter scores the highest ranking among these countries.Making Daikin inverter the best in its class.
Source from Europe, Singapore, Thailand, Hong Kong energy label.
Low High
Europe Class G Class A Class A Singapore 0 Tick 4 Tick 4 TickThailand Level 1 Level 5 Level 5Hong Kong Grade 5 Grade 1
Country Rating Range
Grade 1
Daikin Inverter SeriesRating Score
Malaysia 1 STAR 5 STAR 5 STAR
Penyaman UdaraAir Conditioner
BRANDDaikin
MODELFTK10PV1L/RK10FV1
kWjkWh1355
2013
5
R08024128549A
Produk ini Menggunakan 42%KurangTenaga
This Product Consumes 42%Less Energy Than An AverageProductDaripada Produk Biasa
Diuji Mengikut / Tested AccordingToMS ISO 5151:2004No.Kelulusan COA/ COA Approval Number: SJT161301000052014/SJT161301001002014
8/10/2019 RR-1014-B
5/10
I n v e r t e r
C e
i l i n g
C a s s e t
t e S e r i e s
This feature is complemented by the powerful Turbo Mixed Flow Fan, cools remarkablyfast and evenly to deliver extraordinary cooling efficiency.
28mm (FCR-A2)20mm (FFR-C)
The slim panel can be blended into any decoration anddesign.
In the event of a sudden power failure during operation, unit can be automatically restart(subject to certain protection conditions) from last setting condition. This eliminates theneed to restart manually after each power failure.
This feature enables you to operate the unit even if the remote controller is misplaced orthe remotes battery is weak. Preset at 24C cool mode, just press the forced on buttonfor instant cooling comfort.
Start with cooling to dehumidify and keeps the room dry without much change intemperature.
700mm The unit comes with a built-in high head drain pumpup to 700mm. A safety float is incorporated in thedrain pump to monitor its water level.
Compact and Easy-To Use Handset Prominent temparature display.
Real-time clock display. Easily accessible buttons for On/Off, Temperature Setting, Fan Speed and Mode control.* Applicable for Inverter Wall Mounted, Ceiling Cassette and Ceiling Exposed Convertible Series only
DGS01 WirelessController
8/10/2019 RR-1014-B
6/10
I n v e r t e r
C e
i l i n g
C o n c e a
l e d S e r i e s
Hidden Comfort The application of the FDMR series are installed conveniently above the ceiling, making itan ideal cooling choice for both commercial and residential segments. Highlyrecommended for restaurants, offices and houses with enough ceiling height.
Evergreen PrestigeUnlike other indoor units split air-conditioning, FDMR series wont tarnish along with time.
With its unique concealed application, FDMR series stays evergreen forever.
Even Air Distribution The ducting system distributes air flow remarkably even to all corners of the room,delivering option cooling efficiency and comfort.
Electronic Controller
DSLM 8 Wired Controller
Prominent temperature display. Real time clock display. Easily accessible buttons. Key lock function. Real-time timer ( 7 days option, 2 events daily) Dedicated buttons for Quiet and Turbo function* Applicable for Inverter Ceiling Concealed Series
as standard controller. As optional controller for Inverter Wall Mounted,
Ceiling Cassette, and Ceiling Exposed Convertible Series.
8/10/2019 RR-1014-B
7/10
Automatic Up and Down Air Swing The motorized louver enables the air flowto be evenly distributed.
Quiet OperationIndoor noise level is kept at minimal byhigh efficient indoor fan.
Auto Random RestartIt enables the units to restart automatically at different intervals when power resumes aftera blackout.
Strong and Robust The unit is built of rust resistant materials and robust parts to ensure a long-lasting reliable
service.
Last Memory The unit restarts with the last restoredsetting when power resumes.
Ceiling and Wall InstallationOption The Prestige III is uniquely designed withthe option to install either below theceiling or mounted at low wall position tosuit any interior design requirement.
* Wall bracket suppliedas optional item
Excellent Air Distribution The front vanes can be adjusted in fourdifferent directions giving you the controlover the units air to suit yourpreferences.
I n v e r t e r
C e i
l i n g
E x p o s e
d C o n v e r t
i b l e S e r i e s
8/10/2019 RR-1014-B
8/10
8/10/2019 RR-1014-B
9/10
S p e c
i f i c a t i o n s
Inverter Ceiling Exposed Convertible Series
FLR15EV1LWireless
Wired
FLR20EV1L FLR25EV1L
FLR15EV1M FLR20EV1M FLR25EV1M
Btu/hr 12 ,500(5,400-14 ,000)
3,660(1,580-4,100)
910(374-1,252)
4.32(2.03-5.72)
13.74
18,500(5,500-21,000)
5,420(1,610-6,150)
1,660(443-2,160)
7.41(2.25-9.76)
11.14
21,500(5,500-23,000)
6,300(1,610-6,740)
1,990(435-2,174)
8.86(2.32-9.78)
10.80
RR15DV1 RK20CV1 RK25CV1
W
W
A
Btu/hr/W
Refrigerant TypeV/Ph/Hz
CFM 508
46/35
48
550x765x285
520 580Indoor (Hi/Lo) dBA 50/41 53/49
Outdoor dBA
Indoor mm
Outdoor mm
Indoor kg
Outdoor kg
Liquid mm/in
Gas mm/in
R410A220-240/1/50
Total Current (Min-Max)
EER
Power Source
Air Flow Rate
ModelIndoor
Outdoor
Rated Cooling Capacity(Min-Max)
Total Power (Min-Max)
51
756x855x328
Sound PressureLevel
Dimension(H X W X D)
Unit Weight
Copper Pipe Size
1) DUE TO OUR POLICY OF INNOVATION, ALL PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151(NON DUCTED UNIT) OR ISO13253 (DUCTED UNIT).3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN OYLM R&D SOUND ROOM.
218x1,080x630
6.35 / 1/4
5133
24
12.7 / 1/2 15.88 / 5/8
Inverter Ceiling Concealed Series
FDMR10CV1M FDMR15CV1M FDMR20CV1M FDMR25CV1M
RR10DV1 RR15DV1 RK20CV1 RK25CV1
Btu/hr 9,200(4,100-10,500) 12,500(4,600-14,000) 18,500(5,800-21,000) 21,500(5,800-22,500)
W 2,700(1,200-3,080) 3,660(1,350-4,100) 5,420(1,700-6,150) 6,300(1,700-6,590)
W 794(338-1,230) 1,109(432-1,270) 1,590(496-2,025) 1,910(503-2,075)
A 4.22(1.86-5.74) 4.69(2.27-5.84) 7.04(2.48-9.15) 8.51(2.52-9.25)
Btu/hr/W 11.59 11.27 11.64 11.26Refrigerant Type
V/Ph/Hz
CFM 327 410 570 690Indoor (Hi/Lo) dBA 35/26 37/29 38/34 40/36
Outdoor dBA
Indoor mm 261x1,065x411 261x1,200x411Outdoor mm
Indoor kg 24 29Outdoor kg 31 33
Liquid mm/in
Gas mm/in
R410A
220-240/1/50
Total Current (Min-Max)
EER
Power Source
Air Flow Rate
ModelIndoor
Outdoor
Rated Cooling Capacity(Min-Max)
Total Power (Min-Max)
51
756x855x328
51
Sound PressureLevel 48
Dimension(H X W X D)
261x905x411550x765x285
Unit Weight21
Copper Pipe Size
in.wg 0.12External Static Pressure
6.35 / 1/4
12.7 / 1/2 15.88 / 5/89.52 / 3/8
8/10/2019 RR-1014-B
10/10
Branches: Penang Tel: 04-331 1670 Johor Tel: 07-557 7788 Pahang Tel: 09-567 6778 Perak Tel: 05-548 2307
Melaka Tel: 06-288 1133 Sabah Tel: 088-722 194 Sarawak Tel: 082-333 299 Negeri Sembilan Tel: 06-768 8969 Kedah Tel: 04-733 0235 Kelantan Tel: 09-747 4678
Authorized dealer:GROUP ASSOCIATED (C&L) SDN BHD(109719-M)