H2O Series ISO9001 Certification 1Years Warranty S M A R T W A T E R S O L U T I O N S M A D E I N T A I W A N ( R . O . C ) RoHS Outstanding Award © 2018 AQUAS. All rights reserved. Specification and product information contained herein are subject to change without notice. Performance varies depending on hardware, software and overall system configuration. Warrenty and RMA policy varies depending on countries, please check with your local distributors or visit www.aquas.com.tw/en +75°C -25°C WIDE TEMPERATURE ULTRA LOW POWER GOOGLE EARTH 100% UV RESISTANT SECURITY LOCK SOLAR POWER LOG SURGE PRESSURE WIRELESS NETWORK IF THEN ELSE CONTROL RULES MULTIPLE I/O MULTIPLE SENSORS Alarm Profile SMS MESSAGE DATA QA/QC 144.9 144.9 145 8.11 8.11 8.11 S TATISTICS ANALYSIS DATA LOG OPC SERVER BATTERY OPERATION ALARM GPS POSITION GPRS NETWORK GPRS IP68 PROTECT H2O Water Quality Spectrometer Real-Time Monitoring, Cloud Management, Mobile Operation, Anytime and Anywhere Sewer Systems Irrigation Water Treament Reservoir Groundwater Rivers and Streams Drinking Water Simultaneously Monitoring 15 Parameters, including NH4-N, NO3-N, NO2-N, TN, TP, PO4-P, SAC254, COD, TOC, BOD, DOC, COD Mn , BTX, H2S, O3, ChlorophyII a, BGA, CDOM/fDOM, Color, Turbidity, TSS, Transparency Reagent-free, UV-Vis Spectrometry Technology In-Situ, Online Continuous Measurement, No External Sampling Pumps or Pipes Real-time Measurement, Response Time Less Than 10 secs Multiple Parameters Mutual Compensation to Ensure Accuracy and Interference Reduction Onboard Memory Enable Users Easily Calibrate and Configure Sensors at Lab and Distribute to Various Field Sites ■ Ultra Low Power Consumption, Ideal for Outdoor Applications ■ Robust IP68 Enclosure, Continuous Submersible to 100 m of Water ■ Anti-Fouling Automatic Cleaning Wiper, Almost No Maintenance ■ Built-in Standard Modbus RTU Communication Protocol RS485 Communication Water Instruments, Wireless Controller & Logger, Monitoring Bouy, Multiparameter Water Quality Sonde, Water Quality Spectrometer, Handheld Meter, Cloud-Based SCADA Software Sensors, I/O Modules, Data Acquistion, log, Communication, Display, Alarm, Control, Cloud Storage, Big Data Analysis, Artificial Intelligence Creating the Future of Our Water Immersion Type Flow Through Type

RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

H2O Series

ISO9001 Certification

1Years Warranty

SMA

RT WATER SOLUTIONS

MADE IN TAIWAN(R.O

.C)

RoHS

OutstandingAward

© 2018 AQUAS. All rights reserved. Specification and product information contained herein are subject to change without notice. Performance varies depending on hardware, software and overall system configuration.Warrenty and RMA policy varies depending on countries, please check with your local distributors or visit www.aquas.com.tw/en

+75°C-25°C

WIDETEMPERATURE

ULTRA LOWPOWER

GOOGLEEARTH

100%

UVRESISTANT

SECURITYLOCK

SOLARPOWER

LOG

SURGEPRESSURE

WIRELESSNETWORK

IFTHENELSE

CONTROLRULES

MULTIPLEI/O

MULTIPLESENSORS

AlarmProfile

SMSMESSAGE

DATAQA/QC

144.9144.9 145

8.118.118.11

STATISTICS ANALYSIS

DATALOG

OPCSERVER

BATTERYOPERATION

ALARM GPS POSITION

GPRSNETWORK

GPRS

IP68PROTECT

H2O Water Quality SpectrometerReal-Time Monitoring, Cloud Management, Mobile Operation, Anytime and Anywhere

Sewer Systems IrrigationWater Treament ReservoirGroundwater Rivers and Streams Drinking Water

■ Simultaneously Monitoring 15 Parameters, including NH4-N, NO3-N, NO2-N, TN, TP, PO4-P, SAC254, COD, TOC, BOD, DOC, CODMn, BTX, H2S, O3, ChlorophyII a, BGA, CDOM/fDOM, Color, Turbidity, TSS, Transparency■ Reagent-free, UV-Vis Spectrometry Technology■ In-Situ, Online Continuous Measurement, No External Sampling Pumps or Pipes ■ Real-time Measurement, Response Time Less Than 10 secs■ Multiple Parameters Mutual Compensation to Ensure Accuracy and Interference Reduction■ Onboard Memory Enable Users Easily Calibrate and Configure Sensors at Lab and Distribute to Various Field Sites ■ Ultra Low Power Consumption, Ideal for Outdoor Applications ■ Robust IP68 Enclosure, Continuous Submersible to 100 m of Water■ Anti-Fouling Automatic Cleaning Wiper, Almost No Maintenance ■ Built-in Standard Modbus RTU Communication Protocol

RS485 Communication

Water Instruments, Wireless Controller & Logger, Monitoring Bouy, Multiparameter Water Quality Sonde, Water Quality Spectrometer, Handheld Meter, Cloud-Based SCADA Software

Sensors, I/O Modules, Data Acquistion, log, Communication, Display, Alarm, Control, Cloud Storage, Big Data Analysis, Artificial IntelligenceCreating the Future of Our Water

Immersion Type

Flow Through Type

Page 2: RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

H2O Series

The H2O water quality spectrometer is designed especially for real-time water quality monitoring such as NH4-N, NO3-N, NO2-N, TN, TP, PO4-P, SAC254, COD, TOC, BOD, DOC, CODMn, BTX, H2S, O3, ChlorophyII a, BGA, CDOM/fDOM, Color, Turbidity, TSS, Transparency ...etc.

The sonde is connected directly via RS485, providing real-time, simple, reliable, cost-saving data with remote monitoring, configuration and diagnostics capabilities.

With robust IP68 enclosure, it is ideally installed in reservoirs, rivers and lakes.

■ River, lake, reservoir ■ Groundwater level and water quality monitoring■ Wastewater■ Drinking Water

■ Fishery ■ Irrigation■ Industrial Process

1

Applications

Measurement PrincipleReagentless UV-Vis Spectrum Measurement H2O spectrometer continuously online realtime measures multiple water quality parameters such as NH4-N, NO3-N, NO2-N, TN, TP, PO4-P, SAC254, COD, TOC, BOD, DOC, CODMn, BTX, H2S, O3, ChlorophyII a, BGA, CDOM/fDOM, Color, Turbidity, TSS, Transparency ...etc. directly in-situ without intensive sample pre-treatment.

The lamp emits UV-Vis light passing through the sample to be analysed. The spectrometer resolve the wavelength into 1 nm. Using the high resolution spectrum, field testing, lab experiment data and advanced algorithms to provide the concentrations of multiple parameters and eliminates mutual interferences such as chemicals, turbidity color and bubble.

Built-in an auto wiper to remove the fouling and contamination of optical windows to reduce the maintenance cost.

Creating the Future of Our Water

Color

TPTN

(nm)

200 250 300 350 400 450 500 550 800

SAC254CODeqTOCeqBODeqDOCeqCODMN

O3

BTX

NH4-NNO3NO2

Turbidity/TSS

Sample2

Sample1

Wiper

Motor Reference Light

Measurement Light

LampInput slit

Collimating lensTransmission grating

Focus lensImage sensor

Microprocessor

RS485 Port

Absorbtance

Page 3: RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

H2O Series

2

Specifications

Specifications

General■ Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology■ Light source: UV-Vis lamp■ Light path: 1, 2, 5, 10, 35 mm (selectable)■ Measurement interval: 10 sec to 1 hour (adjustable)■ Operating temperature: -10~50 oC■ Operating pressure: max. 10 Kgf/cm2

■ Protection: IP68, continuous submersible to 100 m of water■ Flow rate: max.3 m/s■ Safety: CE, FCC

RS485 Port ■ Data collection, calibration■ Data formate: 19,200 bps, 8 bits, no parity, 1 stop bit■ Surge protection: 4,000 V DC■ Protocol: Modbus RTU

Housing■ Body: Titanium ■ Anti-corrosive Titanium connectors ■ 1500N tensile strength Kelvar reinforced cable ■ Dimensions: Φ80x385(H) mm■ Weight: 2 Kg

Data Collection■ Standard Modbus RTU protocol■ Standard CSV log formatPowerExternal Power■ Voltage: 5 V DC ±5%, 1.5A; 12 V DC ±10%, 1A (optional)■ Surge protection: 4,000 V DC■ ESD line protection:15 KV DC

Maintenance■ Interval: every 3 months■ Calibration: typically 6 to 12 months after installation

Sensor Measurement range Accuracy ResolutionSAC254 0~60 /600 /1,500 /3,000/5,000 m-1 ±5% in standard solution 0.5 m-1

Chemical Oxygen Demand (COD) 0~ 100 /1,000 / 2,500 /5,000 /10,000/20,000 mg/L ±5% in standard solution 0.1 mg/L

Total Organic Carbon (TOC) 0~ 10 /100 /1,000 /5,000/10,000 mg/L ±5% in standard solution 0.1 mg/LBiochemical Oxygen Demand (BOD) 0~ 25 /100 /500 /1,000/5,000 mg/L ±5% in standard solution 0.1 mg/LDissolved Organic Carbon (DOC) 0~ 25 /100 /1,000 /5,000 mg/L ±5% in standard solution 0.1 mg/LPermanganate Index (CODMn) 0~ 25 /100 /1,000 mg/L ±5% in standard solution 0.1 mg/LNitrate (NO3-N) 0~25/50 /100 /1,000 mg/L ±5% in standard solution 0.1 mg/LNitrite (NO2-N) 0~1/ 5/25/100 mg/L ±5% in standard solution 0.1 mg/LBenzene, Toluene, Xylene, Phenol (BTX) 0~ 10 / 100/ 1,000 mg/L ±5% in standard solution 0.1 mg/LSulfides (H2S) 0~ 25 mg/L ±5% in standard solution 0.1 mg/LOzone (O3) 0~ 2/20/200 mg/L ±5% in standard solution 0.1 mg/LChlorophyll a 0~ 400 μg/L; 0~100 RFU Linearity R2 > 0.999 for serial

dilution of Rodamine WT solution equivalents

0.01 μg/L; 0.01 RFU

Blue Green Alage (BGA, PC) 0~ 100 μg/L; 0~200,000 cells/ml Linearity R2 > 0.999 for serial dilution of Rodamine WT solution equivalents

0.01 μg/L; 1 cells/ml

Fluorescent Dissolved Organic Mtter (CDOM/fDOM) 0~1,250/5,000 μg/L

Linearity R2 > 0.999 for serial dilution of Quinine Sulfate solution equivalents

0.01 μg/L

Ammonia (NH4-N) 0~ 2/10/100/1,000 mg/L ±5% in standard solution 0.1 mg/LTotal Nitrogen (TN) 0~ 2/10//20/50/100/1,000 mg/L ±5% in standard solution 0.1 mg/LTotal Phosphorous (TP) 0~ 0.5/10/20/100 mg/L ±5% in standard solution 0.1 mg/LPhosphate (PO4-P) 0~ 0.5/10/20/100 mg/L ±5% in standard solution 0.1 mg/L

Turbidity 0~ 100/1,000/4,000 NTU ±5% FS 0.01 NTU

Total Suspended Solids (TSS) 0~ 200/2,000/10,000/50,000 mg/L ±5% FS 0.1% mg/L

Color (true) 0~ 50/500/1,000 Hazen (Pt/Co, APHA, PCU) ±5% FS 0.01 Hazen (Pt/Co)Color (apparent) 0~ 50/500/1,000 Hazen (Pt/Co, APHA, PCU) ±5% FS 0.01 Hazen (Pt/Co)Transparancy 0~2 m ±5% FS 1 mmTemperature -10~50 oC ±0.1 oC 0.01 oC

Creating the Future of Our Water

Page 4: RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

Parameter Typical applications RangesAmmonium (NH4-N) ■ Water treatment

■ Wastewater■ Ultra-pure water■ Boiler feedwater■ Wastewater: optimization nitrification/denitrification

0~2 mg /l 0~10 mg/l0~100 mg/l0~1,000 mg/l

Chemical Oxygen Demand (COD) ■ Raw wastewater, inflow and outflow monitoring■ Raw wastewater, load control■ Industrial discharger monitoring■ Monitoring of cooling water■ Surface water

0~100 mg/l0~1,000 mg/l0~5,000 mg/l0~10,000 mg/l0~20,000 mg/l

Total Phosphate (TP) ■ Surface water■ Wastewater■ Boiler feedwater■ Cooling tower water

0~0.5 mg/l0~10 mg/l0~20 mg/l0~100 mg/l

Permanganate Index (CODMn) ■ Surface water 0~25 mg/l0~100 mg/l0~1,000 mg/l

Ozone (O3) ■ Drinking water■ Industrial Process

0~2 mg/l0~20 mg/l0~200 mg/l

ChlorophyII a ■ Surface water 0~400 μg /l ; 0~100 RFU

Blue Green Alage (BGA, PC) ■ Surface water 0~100 μg /l; 0~200,000 cells/ml

Fluorescent Dissolved Organic Matter (CDOM/fDOM)

■ Surface water 0~1,250/5,000 μg /l

Nitrate (NO3-N) ■ Drinking water■ Monitoring in the outlet of wastewater treatment plants■ Monitoring and optimization of denitrification stages■ Wastewater: optimization nitrification/denitrification

0~25 mg/l0~50 mg/l0~100 mg/l0~1,000 mg/l

Nitrite (NO2-N) ■ Water treatment■ Wastewater

0~1 mg /l0~5 mg /l0~25 mg /l0~100 mg /l

Phosphate (PO4-P) ■ Surface water■ Wastewater■ Drinking water■ Boilerwater■ Cooling tower wate

0~0.5 mg/l0~5 mg/l0~20 mg/l0~100 mg/l

Total Nitrogen (TN) ■ Surface water■ Wastewater

0~2 mg /l0~10 mg/l0~20 mg/l0~50 mg/l0~100 mg/l

Spectral Absorption Coefficient (SAC254) ■ Continuous monitoring of wastewater for organic pollution

■ Special measuring tasks in UV range■ Surface water■ Drinking water

0~60 m-10~600 m-10~1,500 m-10~3,000 m-10~5,000 m-1

Total Suspended Solids (TSS) ■ Sludge activation■ Municipal wastewater treatment plants

0~100 mg/l0~1,000 mg/l0~10,000 mg/l0~50,000 mg/l

Total Organic Carbon (TOC) ■ Municipal water containing solids■ Very polluted industrial wastewater■ Chemical industry■ Municipal wastewater treatment plants■ Industrial wastewater (depends on application)■ Continuous monitoring of wastewater for organic loads■ Surface water■ Drinking water

0~10 mg/l0~100 mg/l0~1,000 mg/l0~5,000 mg/l0~10,000 mg/l

Turbidity■ Water treatment■ Surface water■ Drinking water

0~100 NTU0~1,000 NTU0~4,000 NTU

Color ■ Drinking water■ Wastewater■ Chemical industry

0~50 Hazen0~1,000 Hazen0~1,000 Hazen

Transparancy ■ Surface water 0~2 mBenzene, Toluene, Xylene, Phenol (BTX)

■ Industrial discharge monitoring 0~10 mg/l0~100 mg/l0~1,000 mg/l

Sulfides (H2S) ■ Industrial discharge monitoring■ Surface water

0~25 mg/l

H2O Series

3

Application Guide

Creating the Future of Our Water

Page 5: RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

H2O Series

System Architecture

AQWEB/AQOPC Station■ Notebook with AQCFG software for configuration■ AQWEB WEB Server software for configuration, automatic data acquisition and storage, remote monitoring, alarming, control, Google Earth fusion display, data analysis, transient pressure analysis, time series trend graph and tabular report functions■ Seamless SCADA software and database connectivity via AQOPC OPC server ■ AQLIB Application interface library (API) for developing user customized software

ARK Water Quality Buoy/ PRO Wireless Controller / HMI Multiparameter Controller■ Periodically sample digital transmitters, logged with time stamp■ Borderless cellular and Ethernet communication■ Peer to peer communication

H2O Multiparameter Water Quality Spectrometer■ RS485 serial communication■ Standard Modbus RTU protocol■ Up to 1.2 Km transmission distance

The H2O Series is built-in RS485 communication, providing seamless connections to public or private network.

4

iPhone

BlackBerry

Android

Safari

IE

Smart Water Cloud

● Administration● Registration● Monitoring● Configuration

AQUAS

www.aquascloud.com.tw

● Alarm Management● Control ● Trend● Statistic Analysis

iPad

N

W

S

E

NW

SW

SE

NE

Water Quality Spectrometer

Monitoring & Operation

Alarm

Trend

Data Analysis

Flow Chart

H2O

Registration

Configuration

Alarm

Control

Data&ImageUpload/Download

Support● Auto Registration● Account Management● Region Management● Remote Diagnosis

Operation● Remote Configuration● Monitoring● Alarm● Control● Trend● Graph● Statistics Report

Maintainance● Firmware Update● Auto Synchronization● Battery Status● Communication Quality● Sensor Calibration and Diagnosis

Cellular/WiFi

SMS/FTP

HMIARK PRO

Creating the Future of Our Water

Page 6: RS485 Communication H2O Water Quality Spectrometer · H2O Series 2 Specifications Specifications General Measurement principle: reagent-free, UV-Vis 200~800 nm Spectrometry technology

H2O Series

5

Block Diagram

► RS485 Port ● Data collection ● Calibration

►External Power ● 5 V DC ±10%, 1 A

IP68 high impact housing

Automatic wiper

IP68 high impact housing

Automatic wiper

► RS485 Port ● Data collection ● Calibration

►External Power ● 5 V DC ±10%, 1 A

H2O: Multiparameter Water Quality Spectrometer (Max.15 parameters): NH4-N, NO3-N, NO2-N, TN, TP, PO4-P, SAC254, COD, TOC, BOD, DOC, CODMn, BTX, H2S, O3, ChlorophyII a, BGA, CDOM/fDOM, Color, Turbidity, TSS, Transparency

E-mail: [email protected] ● Phone: +886-2-8797-5358 ● Fax: +886-2-2657-8926Address: AQUAS INC. 4F.-2, No.56, Ln. 321, Yangguang St., Neihu Dist., Taipei City 114, Taiwan

Ordering

Cable, Flow Chamber, HandheldAccessories

Main UnitImmersion TypeFlow Through Type

Level SensorNoneBuilt-in

Cable Length (m)03 5 10Custom

Cable TypeNonePUR

HousingTitanium

Ordering Codes: H2O 1 1 3- - --

000003005010

001~999

2

03

01

12

85

120

554

642

90

110

308 297

90

Dimensions

PADFLO PRVECO ARKPRO HMI PIM SAOSFC CAB12AWS CAB06 CAB16

Order No. DescriptionPRO Wireless Controller

ECO Wireless Logger

ARK Water Quality Monitoring Buoy

FLO Open Channel Flow Meter

PRV Wireless PRV Controller

AWS Automatic Water Sampler

HMI Multiparameter Controller

PAD Handheld Meter

SFC Flow Chamber

CAB06 Configuration cable (1.5 m, USB interface)

CAB12 2 ports RS485 cable

CAB16 4 ports RS485 cable

PIM02 Pipe mounting

Creating the Future of Our Water

Immersion Type

Immersion Type

Flow Through Type

Flow Through Type