Upload
jgjr2000
View
115
Download
6
Tags:
Embed Size (px)
Citation preview
Copyright © 2008 Rockwell Automation, Inc. All rights reserved.
RSLogix 5000 Release 17.00
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 204/08/23
Logix V17 Extensions
• Software Extensions– Partial Import / Export of Routines and Programs– Full Project XML (L5X) Import/Export– Offline Partial Import of Modified UDT with Data Pres
ervation– Runtime Partial Import of Routines, Programs, and N
EW Add-On-Instructions– Multi-Lingual project documentation with Language S
witching– Controller on-line project change logging
• Programming Languages Enhancements– LD Instruction Parameter Display Optimization Optio
ns– FBD Advanced Process Control Blocks (Smith Predi
ctor, Coordinated Control, Multivariable control) – SFR Instruction Filters Routine Types and Step Nam
es– Option to hold SFC Step / Action Timer “Acc” when c
hart is paused– SFC Chart Paused State Via GSV Instruction– Tag’s Description Added to Tooltips in FBD Editor– GuardLogix SIL 3 Instructions Extensions
• Motion Enhancements– Motion multi-axis programmable Jerk– MCD and MCCD Motion Instructions Enhancements
• Reporting– Controller Organizer Report
• Usability Extensions– Forcing and Toggle Bit Added to Quick Watch Window– Tag Monitor Enhancement - Alarm Grid Display Mode– Search Item Browser Supports Tag Name Typeahead– ControlFlash v7.0 Enhancements– Coordinated System Time (CST) Master Existence
Check On Download– Tag’s Descriptions Length Extended – Produced / Consumed Tag Status– Verification Warning If Forces Are Present– Verification Warning If AFI Are Present– System Install Enhancements– Start Page Enhancements– Decorated Data Support in L5X Import/Export Files
• Miscellaneouos– RSLogix 5000 Professional Concurrent– RSLogix 5000 Standard Concurrent– RSLogix 5000 Professional Changes– Microsoft Windows Vista Support
• RSI Integration– FactoryTalk AssetCentre Archive Check-In/Out– RSLogix Architect Library Management
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 304/08/23
Logix V17 Extensions Continued
• New Network and I/O Module Profiles– Flex 1794-IJ2I Isolated Counter– Flex 1794- IF4XOF4I 4pt In / 4pt Out
Combination Isolated Analog– Flex 1794-IG16, OG16, IH16, IV32, OV32,
IM16, OM16– Flex 1794-IT8/B, 1794-IR8/B, 1794-IF8I and
1794-OF8I– ControlLogix 1756-EN2F Major rev 2– ControlLogix 1756-CFM Counter Major Rev 2
(Config output based on freq)– ControlLogix 1756-OB8I 8pt Isolated DC
Output– 1768 Compact Generic Config Profile– 1757-FFLDC ControlNet to Foundation
Fieldbus Linking Device– Adding PowerFlex 7 & 4 Drives On-line on
EtherNet/IP and ControlNet– Thin profiles for Flex IO modules (1794-
IF8IH/B, 1794-OF8IH/B, 1794-IE8H/B, 1794-OE8H/B, 1797-IE8H/B, 1797-OE8H/B)
– 1797-ACNR15 Major rev 5
• Controller Support– ControlLogix 1756-L65 32MB Memory
Controller– GuardLogix 1756-L63S Controller– CompactLogix 1769-L2x Controllers– Removal of ControlLogix 1756-L55 and
FlexLogix 1794-L34B Controller• Other
– StratixTM Industrial Switch Portfolio– CIP Sync support on 1756-EN2T– Unicast Produced/Consumed Tags for
EtherNet/IP Generic Modules– CIP Generic Module COMM Format of None– Cyclic EDT support for flex adapters (1794-
ACN, 1794-ACNR, 1794-AENT, 1797-ACNR)• Tools
– Logix5000 Update Tool– DELMIA Automation Bi-Directional
Synchronization Utility
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 404/08/23
Program & Routine Partial Import / Export
• V17 provides ability to export Programs, Phases and Routines
– Similar to the V13 LD Rung Partial Import/Export – Includes support for FBD,SFC and ST
• The export “.L5X” file includes all pertinent information– Program configuration, code, user defined data-types,
tags and descriptions– XML formatted ASCII text file– Distribute code separately from the RSLogix 5000 Project
“.ACD” file– The file can be manipulated and even created by other
tools• Create larger libraries of reusable code
– Provides more control over the scope of what will be extracted from the project
– Useful for larger machine, cell or unit control– Promotes standardization and reuse
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 504/08/23
Importing into a project
• To import, select the previously exported Add-On Instruction, program, phase, routine, or UDT you wish to use in your running project and click on Import...
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 604/08/23
Import Configuration dialog
• Provides a listing of all components which will be imported and whether they conflict with existing components already in the running project.
• Allows you to resolve conflicts when collisions occur.
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 804/08/23
Off-line Partial Import of Modified UDT with Data Preservation
• With release V16, we allowed you to import/export a UDT to an XML file
– However, only new UDTs could be imported
• With V17, we are extending this functionality by allowing existing UDTs to be imported while maintaining existing members’ data values
– Data values will be maintained when:• Inserting/adding members• Deleting members• Rearranging (moving) members• Renaming members• Changing the data types of
members– Data values for members renamed and
moved will not be maintained• Improves user experience by allowing
easy UDT maintenance off-line
Added MemberAdded MemberAdded member leaves existing data values unchanged
Old UDT
Updated UDT
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 904/08/23
Runtime Partial Import
• V17 Provides ability to import Programs, Routines and NEW Add-on Instructions on-line with a running controller
– NEW programs, routines and add-on instructions can be added– Existing Programs and routines can be replaced– New tags and UDTs are created as needed– Name collisions are detected automatically and user prompted to
rename or bind to existing components– The data values in the controller are maintained and new tags will
have their values initialized from the import file• Permits ability to manipulate code off-line and deliver to
controller later– ...vs. on-line editing where you must be connected– With some extra effort, existing Add-on Instructions can be
replaced• Must use the following versions of RSLinx to use this feature
– RSLinx Classic V2.54.00 or greater – RSLinx Enterprise V5.17.00 or greater
“.L5X” File
Program
Routine
NEW Add-on Instruction
User-DefinedDatatype
Tags
Data
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 1204/08/23
Runtime Detection of Controller Modifications
• With V17, the 1756 ControlLogix L6x1 and GuardLogix L6xS1 Controllers track on-line changes via an internal log and with change counters– Logs type of change and PC Identity of user making the
change– Stores a list of changes to CompactFlash card for later review– Programmatically accessible (GSV Instruction) counters
increment when a user modifies a running controller
• Provide indication that changes have occurred and post mortem of where the changes are and by whom via the log
• Valuable for FDA regulated applications that need to know the applications has been modified
1 Initially Limited to ControlLogix L6x and GuardLogix L6xS Controllers
ChangeLog
ChangeLog
ChangeCountersChange
Counters
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 1504/08/23
New Advanced Process Control Instructions
• RSLogix 5000 V17 provides three new optional advanced process control (APC) instructions
– Internal Model Control (IMC) – Compares actual process error against error calculated by an internal first order lag plus deadtime model
– Coordinated Control (CC) - Controls a single process variable by manipulating as many as three different outputs
– Modular Multivariable Control (MMC) - Controls two process variables to their setpoints using up to three controller outputs
– Useful for applications with multiple interacting inputs/outputs or with long deadtimes
• Instructions purchased separately and licensed per use– 9324-RLDAPCENE – provides a license to use the
instructions in RSLogix 5000 and provides a license to use them in a single Logix controller - $3,000 US List Price
– 9324-RLDAPCCLENE - provides a license to use the instructions in an additional controller (honor system for run-time license, may change in the future) - $1,000 US List Price
IMC_01
IMC ...
Internal Model Control
0.0PV
0.0SPProg
0.0SPCascade
0.0RatioProg
0.0CVProg
0.0HandFB
0ProgProgReq
0ProgOperReq
0ProgCasRatReq
0ProgAutoReq
0ProgManualReq
0ProgOverrideReq
0ProgHandReq
CVEU0.0
SP0.0
ProgOper0
CasRat0
Auto0
Manual0
Override0
Hand0
IMC_01
IMC ...
Internal Model Control
0.0PV
0.0SPProg
0.0SPCascade
0.0RatioProg
0.0CVProg
0.0HandFB
0ProgProgReq
0ProgOperReq
0ProgCasRatReq
0ProgAutoReq
0ProgManualReq
0ProgOverrideReq
0ProgHandReq
CVEU0.0
SP0.0
ProgOper0
CasRat0
Auto0
Manual0
Override0
Hand0
CC_01
CC ...
Coordinated Control
0.0PV
0.0SPProg
0.0CV1Prog
0.0CV2Prog
0CV3Prog
0ProgProgReq
0ProgOperReq
0ProgCV1AutoReq
0ProgCV2AutoReq
0ProgCV3AutoReq
0ProgCV1ManualReq
0ProgCV2ManualReq
0ProgCV3ManualReq
0ProgCV1OverrideReq
0ProgCV2OverrideReq
0ProgCV3OverrideReq
CV1EU0.0
CV2EU0.0
CV3EU0.0
SP0.0
ProgOper0
CV1Auto0
CV2Auto0
CV3Auto0
CV1Manual0
CV2Manual0
CV3Manual0
CV1Override0
CV2Override0
CV3Override0
CC_01
CC ...
Coordinated Control
0.0PV
0.0SPProg
0.0CV1Prog
0.0CV2Prog
0CV3Prog
0ProgProgReq
0ProgOperReq
0ProgCV1AutoReq
0ProgCV2AutoReq
0ProgCV3AutoReq
0ProgCV1ManualReq
0ProgCV2ManualReq
0ProgCV3ManualReq
0ProgCV1OverrideReq
0ProgCV2OverrideReq
0ProgCV3OverrideReq
CV1EU0.0
CV2EU0.0
CV3EU0.0
SP0.0
ProgOper0
CV1Auto0
CV2Auto0
CV3Auto0
CV1Manual0
CV2Manual0
CV3Manual0
CV1Override0
CV2Override0
CV3Override0
MMC_01
MMC ...
Modular Multivariable Control
0.0PV1
0.0PV2
0.0SP1Prog
0.0SP2Prog
0.0CV1Prog
0.0CV2Prog
0CV3Prog
0ProgProgReq
0ProgOperReq
0ProgCV1AutoReq
0ProgCV2AutoReq
0ProgCV3AutoReq
0ProgCV1ManualReq
0ProgCV2ManualReq
0ProgCV3ManualReq
0ProgCV1OverrideReq
0ProgCV2OverrideReq
0ProgCV3OverrideReq
CV1EU0.0
CV2EU0.0
CV3EU0.0
SP10.0
SP20.0
ProgOper0
CV1Auto0
CV2Auto0
CV3Auto0
CV1Manual0
CV2Manual0
CV3Manual0
CV1Override0
CV2Override0
CV3Override0
MMC_01
MMC ...
Modular Multivariable Control
0.0PV1
0.0PV2
0.0SP1Prog
0.0SP2Prog
0.0CV1Prog
0.0CV2Prog
0CV3Prog
0ProgProgReq
0ProgOperReq
0ProgCV1AutoReq
0ProgCV2AutoReq
0ProgCV3AutoReq
0ProgCV1ManualReq
0ProgCV2ManualReq
0ProgCV3ManualReq
0ProgCV1OverrideReq
0ProgCV2OverrideReq
0ProgCV3OverrideReq
CV1EU0.0
CV2EU0.0
CV3EU0.0
SP10.0
SP20.0
ProgOper0
CV1Auto0
CV2Auto0
CV3Auto0
CV1Manual0
CV2Manual0
CV3Manual0
CV1Override0
CV2Override0
CV3Override0
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 2304/08/23
GuardLogix V17 Safety Enhancements
• 20 TÜV / BG Certified Safety Application Instructions– 9 Metal Forming Instructions (BG)– 3 Muting Instructions (Light Curtains)– 6 New Dual Channel Instructions– Safety Mat– 8 Position Mode Switch
More Information
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 2704/08/23
IA Safety Accelerator – System Design Guidelines/Tools
• A safety control system methodology assisting in device configuration and supporting safety logic tasks.
• A device selection guide based on safety requirements.
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 2804/08/23
IA Safety Toolkit Preconfigured Status and Diagnostic Faceplates/AOIs
• FactoryTalk View Faceplates for GuardLogix Controller and Safety I/O Blocks including companion Logix Add-On Instructions.
Preconfigured Faceplate
Companion Add-On Instruction
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 3704/08/23
ControlFlash V7.0 – Simplifies Firmware Management
• Allows ControlFlash to run with no GUI – Reduce training requirements of technicians– Improve time to commission a machine or
performing field upgrades• Command Line Execution
– Allows command line execution of ControlFlash for simple Batch File flashing or custom VB app
• Script Execution– Allows creation of an ASCII script for
ControlFlash to follow when commissioning or upgrading a machine
– Script lists the Modules to flash, firmware revs, and path requirements
– Multi- Threaded to allow ControlFlash to flash up to 5 modules simultaneously for improved performance
• Success/Fail Programmatic Feedback – Return strings for command line execution as
well as History Log file for interrogation of success/fail flash events
Example of custom VB application
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 3904/08/23
Tag’s Descriptions Length Extended
• Up to v16 of RSLogix 5000, tags’ description may have been represented with a maximum of 128 characters in length
• With release v17, we are extending the maximum number of characters to 512– Maximum length applies also to Unicode
characters
• Allows for extended descriptions or descriptions in multiple localized languages for the same tag
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 4104/08/23
Verification Warning If Forces Are Present
• In release v17, we are adding the option in the software to warn the user during verification and download that forces are present in the project
• The option is enabled by default
• Provides users with more detailed information on application during debugging and maintenance
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 4204/08/23
Verification Warning If AFI Are Present
• In release v17, we are adding the option in the software to warn the user during verification and download that AFI (Always False Instruction) instructions are present in the project
• The option is enabled by default
• Provides users with more detailed information on application during debugging and maintenance
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 4304/08/23
RSLogix 5000 System Install Enhancement
• System install introduced in v16 is being enhanced in release v17 to allow for installation of other RS products– RSLogix 5000 label indicates that this
is the first disc to install– Customer picks RS Products,
components, firmware kits and tools to install and they are automatically installed in the right order
• Reduces the total time to install and improves user experience
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 4704/08/23
FactoryTalk Activation Grace Period
• RSLogix 5000 v16.03 added support for FactoryTalk Activation (FTA) Grace Period
– Allows you to run software at full functionality for 7 days w/o an activation
– Addresses cases where you cannot immediately get an FTA (no web or no phone) or have lost it
• The RSLogix 5000 install validates the product’s serial # so that it can enable the correct Edition functionality while in Grace Period
– An invalid serial # will set the RSLogix 5000 functionality equal to that of RSLogix 5000 Service Edition
• Note: the software will run as long as a valid activation is detected regardless of the correctness of the serial #
• In v17, we have enhanced the warning dialog when an incorrect serial # is entered during install to better clarify this functionality and streamline the install process
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 4804/08/23
RSLogix 5000 Professional Concurrent
• With release v17, an additional RSLogix 5000 Professional Edition will be available with concurrent licensing– Catalog #: 9324-RLD700NXxxF– Concurrent license pricing US $7,720 per seat– For upgrades use the Step Forward program– Concurrent license will apply to earlier versions – v10 through v16– Earlier <v10 RSLogix 5000 versions use one license per instance
• Concurrent license will apply to RS products in bundle– RSNetWorx 9.x and higher, RSLogix Architect v3.x and higher, and RSLogix
Emulate 5000
• Software is designed to grab highest functionality license first– I.e.; if Standard, Full and Professional Concurrent licenses are available on the FT
Activation server, RSLogix 5000 will grab highest functionality license firstReplace “xx" in the catalog number with the appropriate language designation: DE = German, EN = English, ES = Spanish, FR = French, IT = Italian, JP = Japanese, KO = Korean, PT = Portuguese, and ZH = Chinese
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 4904/08/23
RSLogix 5000 Standard Concurrent
• With release v17, an additional RSLogix 5000 Standard Edition will be available with concurrent licensing– Catalog #: 9324-RLD300xxF– Concurrent license pricing US $3,320 per seat– For upgrades use the Step Forward program– Concurrent license will apply to earlier versions – v10 through v16– Earlier <v10 RSLogix 5000 versions use one license per instance
• Software is designed to grab highest functionality license first– I.e.; if Standard, Full and Professional Concurrent licenses are available on the FT
Activation server, RSLogix 5000 will grab highest functionality license first
Replace “xx" in the catalog number with the appropriate language designation: DE = German, EN = English, ES = Spanish, FR = French, IT = Italian, JP = Japanese, KO = Korean, PT = Portuguese, and ZH = Chinese
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 5004/08/23
RSLogix 5000 Professional Edition Changes
• With release v17, we will include RSLinx Classic Lite with RSLogix 5000 Professional instead of OEM
– This is because of technical constraints when using FT Activation with bundled products that allow concurrent and borrowing licensing
• Existing RSLinx Classic Professional and OEM customers under support will still be able to upgrade their software as needed
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 5104/08/23
Microsoft Windows Vista Support
• RSLogix 5000 Version 17 will be the first version officially tested / validated to run on Windows Vista (32bit) + SP1 (Service Pack 1)
– The following Vista Editions will be used during the testing:
• Windows Vista Home Basic• Windows Vista Business
– Other Vista Editions are expected to support RSLogix 5000, but will not be formally validated
• It is uncertain at this time if there are any issues that need to be addressed that would prevent earlier RSLogix versions from operating on Vista
– If changes to RSLogix 5000 are required, we will have to review them on a case by case basis to determine how to deal with previous releases (V13 thru 16)
• A Vista compatible version of RSLinx Classic will also be released in conjunction with RSLogix 5000 V17
– However, drivers for ISA bus communication cards will be removed from this version
• FBD ActiveX faceplates will not be Vista Compatible– Use FactoryTalk View SE/ME FBD Global Objects
instead
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 5204/08/23
FactoryTalk AssetCentre Archive Project Check-in/out
• RSLogix 5000 Is being updated to support the FactoryTalk AssetCentre Archive– New “Source Control” main menu option provides navigation to tools– New “Source Control” icon on Open file dialog to permit easy selection of archived file.– Dialogs prompt for comments when files are extracted from or replaced to the Archive
• Improves source control tracking of RSLogix 5000 projects– Tracking of access and changes to files– Provides piece of mind that you have the proper file when needed
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 6204/08/23
Adding PowerFlex 7 & 4 Drives On-line
• With RSLogix 5000 v16, we provided integrated profiles for the configuration of PowerFlex 7 and 4 class drives
• With v17, these profiles have been enhanced to allow on-line addition of drives on EtherNet/IP and ControlNet in a running system
– Requires drives AOP v2.01 (Sept. 08)– ControlNet requires 20-COMM-C/-Q (≥v2.007)
and 22-COMM-C (≥v1.005) firmware revision• Applies to all Logix5000 platforms • Allows system expansion without having to
shutdown controller and/or network• Very important for process applications
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 63
Drive AOPs v2.01 (September 2008 Release)
• Features:– New profiles:
• PowerFlex 755– Includes DeviceLogix support
• PowerFlex 4-Class Multi-Drive• PowerFlex 7000-2
– New wizards:• PowerFlex 755 Startup
– Add I/O online• EtherNet/IP• ControlNet
– Requires 20-COMM-C/-Q (≥v2.007) and 22-COMM-C (≥v1.005) firmware modification to allow control via unscheduled messaging
– RSLinx path splicing• Automatically provides the PC-to-Drive RSLinx path so the user does not
have to find the drive in a Who window to perform an upload / download
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 6404/08/23
ControlLogix L65 Series B
• The 1756-L65 Series B controller is an extension of the L6x family of controllers
– Supports 32 MB of user memory
• Shares the benefits of the L6x series B hardware– New battery architecture leverages flash technology to greatly
improve battery life (battery life will be slightly reduced due to more memory)
– CompactFlash card socket is moved to front of controller
• Supported with V17 firmware• Targeted to be available in conjunction with v17 release
– Initially limited to non-redundant systems till V17.5x redundancy release is available
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 6504/08/23
GuardLogix L63S Series B Controller
• New GuardLogix 1756 L63S Controller– 8.0M Standard Memory– 3.75M Safety Memory– Extends the family– L61S and L62S supported with V14 and V16
• Programmatic GSV access to Safety Signature• Targeted to be available in conjunction with V17
release
More Information
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7004/08/23
CompactLogix 1769-L23
• Expands Logix technology to the smaller applications• High functionality in a small package • Packaged to lower acquisition cost and simpler
configuration• Available EtherNet/IP integrated ports for world
class connectivity• Embedded I/O is pre-configured in RSLogix 5000 for ease of use• Expandable, with 2 local I/O cards and networked I/O• Ideal for Logix users in need of lower price controller for small
applications• Support of advanced IA features like Alarms and Events, Drives Premier
Integration or Phase Manager• Database integration with FactoryTalk View and PanelView Plus.
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7104/08/23
New CompactLogix 1769-L23 Product Family
The new Logix packaged controller for smaller The new Logix packaged controller for smaller Integrated Architecture implementations Integrated Architecture implementations
The new Logix packaged controller for smaller The new Logix packaged controller for smaller Integrated Architecture implementations Integrated Architecture implementations
Embedded 24VDC Power Supply
Embedded options for I/O, Discrete, Analog and HSC
Expand with up to 2 adittional 1769
Compact I/O modules
Logix Inside, programmed with RSLogix 5000
Built In Serial and Ethernet/IP Port
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7204/08/23
L23 Controllers Specification Summary
Cat. Number 1769-L23E-QB1B 1769-L23-QBFC1B 1769-L23E-QBFC1B
Embedded Communication Ports
Isolated Serial EtherNet/IP with (MSG + I/O)
Isolated SerialNon-Isolated Serial
Isolated SerialEtherNet/IP with (MSG + I/O)
EtherNet/IP Connections
8 TCP/IP – 32 CIP n/a 8 TCP/IP – 32 CIP
Memory 512 KB 512 KB 512 KB
Embedded I/O(pre-configured in Logix 5000)
16 DC in, 16 DC out 16 DC in, 16 DC out, 4 Analog in, 2 Analog out.
4 High speed counters (250KHz)
16 DC in, 16 DC out, 4 Analog in, 2 Analog out.
4 High speed counters (250KHz)
Expansion 2 Additional 1769 I/O modules OR 1 1769 Comm Module
2 Additional 1769 I/O modules OR 1 1769 Comm Module
2 Additional 1769 I/O modules OR 1 1769 Comm Module
Project Structure 3 Tasks – Continuous, Periodic or Event
3 Tasks – Continuous, Periodic or Event
3 Tasks – Continuous, Periodic or Event
Languages All (LD, FBD, ST and SFC) All (LD, FBD, ST and SFC) All (LD, FBD, ST and SFC)
Alarms & Events Same as L31 Same as L31 Same as L31
PhaseManager Support Same as L31 Same as L31 Same as L31
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7304/08/23
CompactLogix 1769-L23 & RSLogix 5000
• Embedded EtherNet/IP port and I/O are pre-populated when selecting L23 controllers in Logix 5000
• Simplified experience for the customer (Only add expansion or remote IO)
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7404/08/23
Removal of ControlLogix L55 and FlexLogix L34 Controllers from RSLogix 5000 V17
• These controllers are in Silver Series designation effective December 31, 2007 with a last-time-buy deadline of December 31, 2008– See additional information on: http://www.ab.com/silver/controllogix.html and
http://www.ab.com/silver/flexlogix.html
• The last version of firmware for the L55 and L34 controllers was V16– With V17, the firmware would no longer fit within the L34 and L55 controllers
• With Logix most of the firmware content is shared across all controllers• The firmware grows in sized with each release as new functionality is added
– The ControlLogix 1756-L55 controller was initially released with V7 in Dec 15, 2000– The FlexLogix 1794-L34 controller was initially released with V6 Aug 31, 2000
• The L55 and L34 can continue to operate with newer controllers– Communications via messaging and Produced / Consumed Tags– RSLogix 5000 Side-by-side install / Multiple Revision Support permits continued
access and maintenance
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7504/08/23
• Stratix 8000 - Modular Managed with Cisco Technology – Optimized for the Enterprise and Plant Floor– IT Friendly - Cisco operating system, feature set and user interface– Engineer Friendly – RSLogix 5000 configuration, Logix tags and FactoryTalk View faceplates
• Stratix 6000 - Fixed Managed – Optimized for the Plant Floor – Engineer Friendly – RSLogix 5000 configuration, Logix tags and FactoryTalk View faceplates
• Stratix - Embedded Technology– Two Ethernet ports embedded in Rockwell Automation product– Enables high speed ring and linear topologies– No configuration required– Initial Release:
• Stratix 4000 3-port tap• 1756-EN2TR – ControlLogix bridge module
• Stratix 2000 - Fixed Unmanaged – Compact size– IP20 and IP67 versions – No configuration required
• Physical Media - cables, connectors, cordsets
StratixTM Industrial Switch Portfolio
Flexible Choices – Managed, Unmanaged and Embedded
Linear or Ring
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7604/08/23
What is CIP Sync?
• System-wide Time synchronization for CIP-based Networks– CIP Sync™ = CIP Network + IEEE-1588– First Release on 1756-EN2T (V2.0 firmware)
• Provides common time reference for the ControlLogix Architecture over UNMODIFIED standard Ethernet hardware to 100nanoseconds
• Multi-Master time network – self arbitrates for best time source
• Wide application base– Simplified Controller Clock Setting– Alarms and Events– Coordinated outputs– SOE First Fault Detection– History Logging to DB for event re-creation
and simulation– Global System Motion Registration
PTP Clock
Time Sync Objec
t
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 7904/08/23
Logix5000 Data Preserve Tool
• Prior to V17, a project download caused the tags values in a controller to be reset to the off-line project values
• However, there are instances where customers would like to preserve data existing in a controller before doing a download (i.e., recipe or production information)
• With V17, this new tool provides the ability to backup up and restore controller data while performing a project download
– Free tool available on V17 RSLogix 5000 CD– Once installed the tool adds itself to the RSLogix
5000 Tools Menu– Requires RSLogix 5000 to perform the download
• Tool is backward compatible back to release v15 of RSLogix 5000
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 8304/08/23
RSLogix 5000 Packages / Options
RSLogix 5000 Enterprise Series bundles / options
Service Edition3
9324-RLD000ENE
Mini Edition 9324-
RLD200ENE
Lite Edition 9324-
RLD250ENE
Standard Edition 9324-
RLD300ENE
Standard/NetWorx 9324-
RLD300NXENE
Full Edition2
9324-RLD600ENE
Professional 9324-
RLD700NXENE
Logix5000 Controllers Supported
All3 CompactLogixFlexLogix
CompactLogixFlexLogix
All All All2 All
Ladder Diagram View Only Included Included Included Included Included Included
Function Block Diagram1
9324-RLDFBDENE
View Only Separate Option Included Separate Option
Separate Option Included4 Included4
Sequential Function Chart1 & 8
9324-RLDSFCE
View Only Separate Option Included Separate Option
Separate Option Included4 Included4
Structured Text1
9324-RLDSTXEView Only Separate Option Included Separate
OptionSeparate Option Included4 Included4
Safety1 & 6
9324-RLDGLXEView Only n/a n/a Separate
OptionSeparate Option Included4 Included4
PhaseManager1 & 5
9324-RLDPMEView Only Separate Option Separate Option Separate
OptionSeparate Option Included4 Included4
Emulate 5000 9310-WED200ENE
Separate Option
n/a n/a Separate Option
Separate Option Separate Option
Included
PIDE Autotune9323-ATUNEENE
Separate Option
Separate Option Separate Option Separate Option
Separate Option Included7 Included4
1. Able to upload and download without option. Must purchase option to view, edit and print routines in this language
2. Full Edition supports controllers running V10 and higher3. Service Edition supports controllers running V12 and higher4. Must be installed on same PC as RSLogix 50005. PhaseManager supported in V15 and higher
6. Standard Task functionality remains the same7. PIDE Autotune supported V16 and higher8. Requires Structured Text option to program ST assignments
in SFC actions
Copyright © 2008 Rockwell Automation Inc., All Rights Reserved 8404/08/23
RSLogix 5000 Packages / Options (cont.)
RSLogix 5000 Enterprise Series bundles / options
Service Edition3
9324-RLD000ENE
Mini Edition 9324-
RLD200ENE
Lite Edition 9324-
RLD250ENE
Standard Edition 9324-
RLD300ENE
Standard/NetWorx 9324-
RLD300NXENE
Full Edition2
9324-RLD600ENE
Professional 9324-
RLD700NXENE
Integrated-Motion support
View Only n/a Included7 Included Included Included Included
RSLinx Lite Included Lite Included Lite Included Lite Included Lite Included Lite Included Lite Included
RSNetWorx CNet, DNet, and ENet 9357-ANETL3
Separate Option Separate Option
Separate Option Separate Option Included4 Separate Option
Included4
RSLogix Architect9326-LGXARCHENE
Separate Option Separate Option
Separate Option Separate Option Separate Option Separate Option
Included4
Drive Executive Lite9303-4DTE01ENE
Separate Option Separate Option
Separate Option Included Included Included Included
RSLogix 5000 FuzzyDesigner
9324-RLDFZYENE
n/a Separate Option
Separate Option Separate Option Separate Option Separate Option
Separate Option
Mobile license Separate Option Separate Option
Separate Option Separate Option Separate Option Separate Option
Separate Option
Concurrent license n/a n/a n/a Available
(9324-RLD300xxF8)
n/a Available
(9324-RLD600xxF8)
Available
(9324-RLD700NXxxF8)
1. Able to upload and download without option. Must purchase option to view, edit and print routines in this language
2. Full Edition supports controllers running V10 and higher3. Service Edition supports controllers running V12 and higher
4. Must be installed on same PC as RSLogix 50005. PhaseManager supported in V15 and higher6. Standard Task functionality remains the same7. Motion supported in V16 and higher8. Software is designed to grab highest functionality license first
I.e.; if Standard, Full and Professional Concurrent licenses are available on the FT Activation server, RSLogix 5000 will grab highest functionality license first
Copyright © 2008 Rockwell Automation, Inc. All rights reserved.
Questions?