1
E L E C T R O N I C S O L U T I O N S www.kses.net Specifications: ANIDO Module Remote Site Monitor E L E C T R O N I C S O L U T I O N S Address | 469 Julius Jeppe Street Waterkloof, Pretoria Postal | P O Box 25839, Monument Park, 0105 Tel | +27 12 460 4135 Fax | +27 12 460 8719 Email | [email protected] The RSM ANIDO module expands the physical IO capability of the RSM site controller by providing 4 analog inputs, 6 relay outputs and digital ambient temperature and humidity measurement. The module connects to the RSM controller via a power-fed RS485 sensor bus. Better than half a degree temperature accuracy from 0 to 60 °C. Relative humidity accuracy is Two standard RJ12 6P/6C parallel approximately 2% in a typical situation. connectors for easy, daisy-chain connectivity. Power-fed 12V DC bus, 700mA total budget. Typical module consumption excluding RSM standard housing 220mm x 150mm attached analog probes is 30mA at 12V x 42mm. 1U 19” rack mounting bracket with two DC and 250mA when all relay outputs are positions. energised. Wall mount bracket available. 115,200 Kbits/s half duplex RS485 Desktop standalone. interface. 0-5V input range with common ground between inputs. 12-bit analog to digital converter resolution. Typical accuracy 1.5 %. New RMS reading is calculated over period of 160ms every 60 seconds. 12V DC power-fed for easy sensor installation. Standard RJ9 4P/4C connector. Supports Normally Open or Normally Closed operation. Driving capability up to 0.5A at 48V DC or 1A at 24V DC resistive load. Industrial standard 3 pin plugging screw terminal connector. Temperature and humidity measurement Sensor bus Dimensions and mounting options 4 x analog inputs 6 x relay outputs

RSM Spec Sheet - ANIDO Module - electrical …kses.net/RSM Spec Sheet - ANIDO Module.pdf · E L E C T R O N I C S O L U T I O N S Specifications: ANIDO Module Remote Site Monitor

  • Upload
    dinhanh

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RSM Spec Sheet - ANIDO Module - electrical …kses.net/RSM Spec Sheet - ANIDO Module.pdf · E L E C T R O N I C S O L U T I O N S Specifications: ANIDO Module Remote Site Monitor

E L E C T R O N I C S O L U T I O N S

www.kses.net

Specifications:

ANIDO Module

Remote Site Monitor

E L E C T R O N I C S O L U T I O N S

Address | 469 Julius Jeppe Street Waterkloof, PretoriaPostal | P O Box 25839, Monument Park, 0105

Tel | +27 12 460 4135 Fax | +27 12 460 8719 Email | [email protected]

The RSM ANIDO module expands the physical IO capability of the RSM site controller by providing 4 analog inputs, 6 relay outputs and digital ambient temperature and humidity measurement. The module connects to the RSM controller via a power-fed RS485 sensor bus.

· Better than half a degree temperature accuracy from 0 to 60 °C.

·· Relative humidity accuracy is Two standard RJ12 6P/6C parallel approximately 2% in a typical situation.connectors for easy, daisy-chain

connectivity.· Power-fed 12V DC bus, 700mA total

budget. · Typical module consumption excluding · RSM standard housing 220mm x 150mm

attached analog probes is 30mA at 12V x 42mm.· 1U 19” rack mounting bracket with two DC and 250mA when all relay outputs are

positions.energised.·· Wall mount bracket available.115,200 Kbits/s half duplex RS485 · Desktop standalone.interface.

· 0-5V input range with common ground between inputs.

· 12-bit analog to digital converter resolution.

· Typical accuracy 1.5 %.· New RMS reading is calculated over period

of 160ms every 60 seconds.· 12V DC power-fed for easy sensor

installation.· Standard RJ9 4P/4C connector.

· Supports Normally Open or Normally Closed operation.

· Driving capability up to 0.5A at 48V DC or 1A at 24V DC resistive load.

· Industrial standard 3 pin plugging screw terminal connector.

Temperature and humidity measurement

Sensor bus

Dimensions and mounting options

4 x analog inputs

6 x relay outputs