0R&S®M3AR MR6000RR&S®M3AR MR6000L Software Defined RadiosSpecifications
M3AR_MR6000RL_dat-sw_en_5214-3223-22_v0300_cover.indd 1 04.07.2013 11:08:17
Version 03.00, July 2013
2 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
CONTENTS Specifications for the fixed-frequency base unit ......................................................................................................... 3
Built-in interfaces .................................................................................................................................................................................... 3 General technical information ................................................................................................................................................................. 3 General performance data ...................................................................................................................................................................... 5 Transmitter characteristics ...................................................................................................................................................................... 6
Carrier-related ..................................................................................................................................................................................... 6 Modulation-related (voice) ................................................................................................................................................................... 6 Modulation-related (wideband) ............................................................................................................................................................ 6
Receiver characteristics .......................................................................................................................................................................... 7 Main receiver ....................................................................................................................................................................................... 7 Guard receiver ..................................................................................................................................................................................... 7
AF-related outputs of receiver ................................................................................................................................................................. 8 Narrowband output .............................................................................................................................................................................. 8 Wideband output ................................................................................................................................................................................. 8
Environmental data ................................................................................................................................................................................. 9 General environment ........................................................................................................................................................................... 9 Mechanical environment ................................................................................................................................................................... 10
Electromagnetic compatibility (EMC) .................................................................................................................................................... 11 Display color and control panel lighting ................................................................................................................................................ 12 Referenced standards ........................................................................................................................................................................... 13
Ordering information .................................................................................................................................................... 14
R&S®MR6000R R&S®MR6000L
These two transceivers, which come in ARC-164 housings, differ in that the R&S®MR6000R is designed for installation in the avionic bay and can only be remotely controlled, while the R&S®MR6000L is installed in the cockpit and can also be controlled
by a local control panel.
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 3
Specifications for the fixed-frequency base unit Data without tolerance limits is not binding.
Built-in interfaces MIL-STD-1553B data bus (depending on option)
for interaction with the aircraft’s avionic bus system
dual redundant
Serial interface for remote control, e.g. via R&S®GB6500 RS-485 for service purposes RS-232
RF connector for antenna common for tactical VHF, VHF and UHF TNC type Interface for logic converter unit for active antenna Manchester-coded frequency word AF interfaces for voice and user data narrowband and wideband
(baseband/diphase), PTT line Timing system for TOD loading input in line with ICD-GPS-060 Fill interface R&S®KDD, e.g. KYK-13 and AN/CYZ-10 depending on available waveform,
RS-232 for R&S®SECOS, DS-102 for HAVE QUICK/SATURN
External crypto devices KY-58, KY-100, ELCRODAT 4-2; others on request
wideband interface, delayed PTT, etc.
Improved data modem IDM wideband interface, including hop indication for use with HAVE QUICK
ADF broadband interface (R&S®MR6000L only)
for use with external ADF device broadband output
Miscellaneous interfaces e.g. TX/RX inhibit, squelch, emergency clear, switched DC for external devices
General technical information Power supply Nominal supply voltage +28 V DC DC supply range negative terminal connected to chassis +22.5 V to +30 V DC Emergency mode +16 V to +30 V DC DC power consumption in transmit mode under extreme voltage
and/or VSWR conditions ≤ 190 W
in receive mode ≤ 30 W in switched-off state ≤ 0.1 W
Transients > 36 V DC: transmission interrupted, < 14 V DC: transceiver reboots, in line with MIL-STD-704A cat. B
Built-in test (BIT) local and functional error identification down to module level; error messages reported via MIL-STD-1553B data bus, local control panel and serial interface, to be stored in non-volatile memory at unit level PBIT automatic initialization of BIT at power-on
of transceiver CBIT continuous monitoring during operation IBIT initialization of BIT upon command
received via MIL-STD-1553B data bus, local control panel or serial interface
Temperature Operating temperature range –40 °C to +55 °C Functional temperature range R&S®MR6000R –54 °C to +71 °C
R&S®MR6000L –40 °C to +71 °C Storage temperature range –54 °C to +90 °C
Version 03.00, July 2013
4 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
MTBF R&S®MR6000L transceiver AIF, +40 °C > 3000 h,
in line with MIL-HBK-217F, notice 2 AIC, +25 °C > 6000 h,
in line with MIL-HBK-217F, notice 2 ARW, +25 °C > 2400 h,
in line with MIL-HBK-217F, notice 2 R&S®MR6000R transceiver AUF, +40 °C > 2200 h,
in line with MIL-HBK-217F, notice 2 AUC, +25 °C > 4600 h,
in line with MIL-HBK-217F, notice 2 ARW, +25 °C > 2700 h,
in line with MIL-HBK-217F, notice 2 RF connector common for tactical VHF, VHF and UHF
and guard receiver TNC type
Impedance Z = 50 Ω (nom.) Dimensions (W × H × D) R&S®MR6000R transceiver body with lids and connector 127 mm × 121 mm × 209 mm
(5 in × 4.8 in × 8.2 in) body only 127 mm × 121 mm × 176 mm
(5 in × 4.8 in × 6.9 in) R&S®MR6000L transceiver body with lids, connector and control panel 146 mm × 124 mm × 219 mm
(5.7 in × 4.9 in × 8.6 in) body only 127 mm x 121 mm × 165 mm
(5 in × 4.8 in × 6.5 in) Typical values shown – see mechanical interface description for exact values Weight R&S®MR6000R transceiver ≤ 3.6 kg (7.9 lb) R&S®MR6000L transceiver ≤ 3.8 kg (8.4 lb) Typical values shown – see mechanical interface description for exact values Color RAL 9005 (black)
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 5
General performance data All data is valid for plain mode, unless otherwise stated.
Operating frequency ranges 30 MHz to 399.975 MHz Tactical VHF 30 MHz to 87.975 MHz FM (F3E, F1D), in line with STANAG 4204 VHF 108 MHz to 117.975 MHz AM (A3E), receive only
118 MHz to 155.975 MHz AM (A3E) 136 MHz to 173.975 MHz FM (F3E, F1D) 156 MHz to 173.975 MHz FM (G3E)/maritime PM
UHF 225 MHz to 399.975 MHz AM/FM (A3E, A1D, F3E, F1D), in line with STANAG 4205 MSK (R&S®SECOS, SATURN in line with STANAG 4372) AM (A3E, A1D) (HAVE QUICK in line with STANAG 4246)
Frequency accuracy from –40 °C to +55 °C ≤ ±0.5 ppm from +55 °C to +71 °C ≤ ±5.0 ppm aging/1st year ≤ ±1.0 ppm aging/following years ≤ ±0.5 ppm
Channel spacing and presets Channel spacing (MMI display on R&S®MR6000L transceiver in line with ICAO, annex 10, vol. 5)
all bands 25 kHz in ATC VHF frequency range (118.000 MHz to 136.975 MHz)
8.33 kHz and 25 kHz
Number of preset channels 2 sets of 100 each, + 1 guard channel
Number of manual channels 1 The information in the preset channels and in the manual operation channel is stored in non-volatile memory. It is possible to store channel identification names with a maximum length of 15 characters together with the operational parameters in the preset channels. 1 EPM (ECCM) mode (depending on option)
in UHF band (225 MHz to 399.975 MHz) STANAG 4246 (HAVE QUICK I/II), STANAG 4372 (SATURN), R&S®SECOS
Changeover times (10 W RF carrier and 1 mV receive signal)
receive to transmit ≤ 50 ms transmit to receive ≤ 50 ms in EPM (ECCM) mode in line with STANAG 4246 (HAVE QUICK),
STANAG 4372 (SATURN), in line with R&S®SECOS specification
Channel changing time specified for fixed-frequency mode ≤ 50 ms Duty cycle (transmit/receive) High-power mode ≤ 1 min transmit, 5 min receive convectional cooling in operating
temperature range up to +55 °C > 1 min transmit, 5 min receive forced air cooling required
1 Only the first eight characters of the preset description will be displayed on the MMI of the R&S®MR6000L transceiver or of the R&S®GB6500 remote
control unit.
Version 03.00, July 2013
6 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
Transmitter characteristics All data is valid for a 50 Ω non-reactive termination and carrier power measured at a supply voltage from 24 V to 30 V DC, unless otherwise stated.
Carrier-related Output power High-power mode fixed-frequency AM/
HAVE QUICK I/II mode ≥ 10 W
fixed-frequency FM/MSK mode ≥ 15 W Medium-power mode fixed-frequency AM/
HAVE QUICK I/II mode 1.0 W to 2.0 W
fixed-frequency FM/MSK mode 1.5 W to 3.0 W Low-power mode fixed-frequency AM/
HAVE QUICK I/II mode 0.10 W to 0.20 W
fixed-frequency FM/MSK mode 0.15 W to 0.30 W RF carrier power degradation (relevant only in high-power mode)
at +22 V DC ≤ 1.5 dB at VSWR = 2 ≤ 1.0 dB at +55 °C to +71°C and duty cycle ≤ 1:5 ≤ 3.0 dB
Emergency operation (high-power mode under all conditions) DC supply voltage in line with MIL-STD-704A ≥ +16 V DC RF carrier power ≥ 1 W Modulation distortion ≤ 15 % Modulation depth ≥ 60 % Transmit broadband noise Δf = ±25 kHz ≤ –70 dBm (1 Hz)
Δf = ±10 MHz ≤ –115 dBm (1 Hz) Δf ≥ ±20 MHz ≤ –120 dBm (1 Hz)
Harmonic spurious signals 2nd harmonic ≤ –57 dBc 3rd harmonic ≤ –60 dBc 4th to 7th harmonic ≤ –70 dBc
Non-harmonic spurious signals ≤ –34 dBm Pilot tone in tactical VHF range added to TX AF signal 150 Hz (nom.), d = 1.5 kHz Calling tone f = 1020 Hz ± 20 Hz, m ≥ 0.8, k ≤ 10 %
Modulation-related (voice) Input impedance R&S®MR6000R transceiver 600 Ω ± 60 Ω or 150 Ω ± 30 Ω
R&S®MR6000L transceiver 150 Ω ± 30 Ω AF narrowband input sensitivity for m ≥ 0.8 (AM) or d ≥ 5.7 kHz (FM) –6 dBm to +14 dBm, adjustable AF narrowband frequency response with 1 kHz signal
25 kHz channel spacing 300 Hz to 3500 Hz, flat within ≤ 3 dB; ≥ 12 dB at 200 Hz; ≥ 20 dB at 6 kHz
8.33 kHz channel spacing 300 Hz to 2500 Hz, flat within ≤ 6 dB AF narrowband modulation distortion m = 0.8, fmod = 1 kHz ≤ 10 % Signal-to-noise ratio ITU-T weighted, m = 0.80, fmod = 1 kHz ≥ 40 dB Synchronous FM in AM mode ITU-T weighted, m = 0.8, fmod = 1 kHz ≤ 2 kHz Synchronous AM in FM mode ITU-T weighted, d = 5.7 kHz, fmod = 1 kHz ≤ 4 %
Modulation-related (wideband) AF wideband input
Balanced input 600 Ω ± 60 Ω AF wideband input sensitivity for m ≥ 0.80 (AM) 4 V (Vpp) into 600 Ω input
for 30 MHz to 88 MHz (FM): ∆f = 5.0 kHz ± 1 kHz in line with STANAG 4204 for 108 to 400 MHz (FM): ∆f = 5.5 kHz ± 1 kHz in line with STANAG 4205
AF wideband frequency response baseband from 30 Hz to 11 kHz ≤ 4 dB diphase from 30 Hz to 22 kHz ≤ 4 dB at 50 kHz ≥ 20 dB
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 7
Receiver characteristics
Main receiver Sensitivity 10 dB (S+N)/N unweighted, fmod = 1 kHz
30 MHz to 400 MHz, Δf = 2.4 kHz –104 dBm 108 MHz to 400 MHz, m = 0.30 –101 dBm
Internal noise level ≥ 30 dB Selectivity (IF bandwidth) Clear voice (ICAO 8.33 kHz)
bandwidth at 6 dB > 7 kHz bandwidth at 60 dB < 11 kHz (digital filter)
Clear voice (ICAO 25 kHz)
bandwidth at 6 dB > 22 kHz bandwidth at 60 dB < 50 kHz (digital filter)
Wideband bandwidth at 6 dB > 50 kHz bandwidth at 60 dB < 60 kHz (digital filter)
EPM modes bandwidth at 6 dB > 40 kHz bandwidth at 60 dB < 60 kHz (digital filter)
Passband ripple ≤ 3 dB Spurious response rejection IF rejection ≥ 70 dB Image rejection ≥ 70 dB Spurious rejection at Δf > 1 MHz ≥ 70 dB For a limited number of frequencies (≤ 5) mathematically related to the tuned frequency, a deviation of max. 10 dB from the specific value is possible. Crossmodulation rejection at Δf ≥ 3 MHz, Vinterf/Vuseful = 10 %, relative
to sensitivity limit (Vinterf m = 0.6) ≥ 70 dB
Third-order intermodulation rejection at Δf > 10 MHz for tactical VHF and Δf > 10 % for VHF/UHF
≥ 80 dB
Internal spurious Number of channels with (S+N)/N degraded due to internal spurious
tactical VHF ≤ 10 channels VHF ≤ 15 channels UHF ≤ 20 channels
AGC/ALC characteristic AM, –98 dBm to +0 dBm ≤ 6 dB FM, –102 dBm to +0 dBm ≤ 6 dB no blocking up to +7 dBm no damage up to +30 dBm
Squelch nominal setting 10 dB (S+N)/N overlap for nominal setting 1.5 dB to 6.0 dB adjustable to 6.0 dB to 15.5 dB (S+N)/N attack time ≤ 50 ms
Guard receiver The guard receiver shares the RF antenna input with the main receiver, and both the main receiver and the guard receiver are able to receive RF signals simultaneously.
Supported guard frequencies tactical VHF 40.500 MHz; FM VHF 121.500 MHz; AM UHF 243.000 MHz; AM
Sensitivity 40.500 MHz, fmod = 1 kHz, Δf = ±2.4 kHz for (S+N)/N = 10 dB ≤ –104 dBm
121.5 MHz, 243.0 MHz, m = 0.30, fmod = 1 kHz for (S+N)/N = 10 dB ≤ –101 dBm
Internal noise level ≥ 30 dB Frequency accuracy ≤ ±5 ppm Selectivity (IF bandwidth) Guard 6 dB bandwidth > 28 kHz
60 dB bandwidth < 80 kHz Spurious response rejection IF rejection ≥ 70 dB Image rejection ≥ 70 dB Spurious rejection same conditions as for main receiver ≥ 70 dB Crossmodulation rejection same conditions as for main receiver ≥ 70 dB Intermodulation rejection same conditions as for main receiver ≥ 70 dB
Version 03.00, July 2013
8 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
AGC/ALC characteristics AM –98 dBm to +0 dBm ≤ 6 dB FM –102 dBm to +0 dBm ≤ 6 dB no blocking up to +7 dBm no damage up to +30 dBm
Squelch nominal setting 10 dB (S+N)/N overlap for nominal setting 1.5 dB to 6.0 dB adjustable to 8 dB to 15.5 dB attack time ≤ 50 ms
AF-related outputs of receiver
Narrowband output Characteristics are specified for an RF receive level of 1 mV, fmod = 1 kHz.
Output impedance 150 Ω radio version ≤ 50 Ω (150 Ω nominal load impedance) 600 Ω radio version ≤ 200 Ω (600 Ω nominal load impedance)
Audio level at m = 0.6 (AM) or Δf = 4.8 kHz (FM) 1.5 mW to 200 mW into 150 Ω or 600 Ω, adjustable, set via MIL-STD-1553B data bus or serial configuration command
AF frequency response 300 Hz to 3500 Hz, main receiver ≤ 3 dB 350 Hz to 3500 Hz, guard receiver ≤ 3 dB at 200 Hz ≥ 12 dB at 6 kHz ≥ 20 dB
Audio distortion at m = 0.6 (AM) or Δf = ±4.8 kHz (FM) ≤ 5 %
Wideband output Output impedance ≤ 200 Ω (600 Ω nominal load impedance) Output level m = 0.80 (AM) or Δf = ±6.25 kHz (FM) 5.6 V to 9.0 V (Vpp) Frequency response 30 Hz to 22 kHz ≤ 4 dB
at 50 kHz ≥ 20 dB Audio distortion m = 0.8 (AM) or Δf = ±6.25 kHz (FM) ≤ 10 %
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 9
Environmental data The tests performed for environmental compatibility depend on the type of transceiver.
Right columns (Rem. and Loc.) point out the applicability where Rem. means the test is applicable for the remote controlled radio R&S®MR6000R and Loc. means the test is applicable for the local controlled transceiver R&S®MR6000L.
General environment Subject Additional information Applied standard Rem. Loc. Temperature
Low operating temperature –54 °C ambient (degraded performance)
MIL-STD-810E, method 502.3, proc. II,
–40 °C ambient MIL-STD-810E, method 502.3, proc. II MIL-STD-810B, method 502, proc I
High operating temperature +71 °C ambient (degraded performance)
MIL-STD-810E, method 501.3, proc. II,
+71 °C ambient MIL-STD-810B, method 501, proc. I +55°C ambient MIL-STD-810E, method 501.3, proc. II
Low storage temperature –54 °C ambient MIL-STD-810E, method 502.3, proc. I
MIL-STD-810B, method 502, proc I High storage temperature +90 °C ambient MIL-STD-810E, method 501.3, proc. I
+95 °C ambient MIL-STD-810B, method 501, proc. I Temperature variation and shock
–40 °C to +75°C (non-operational mode)
MIL-STD-810E, method 503.3, cat. A1, C2 –
–54 °C to +71°C (operational mode), < 70 s transfer time
MIL-STD-810B, method 503 –
Contamination by fluids MIL-STD-810F, method 504 Solar radiation (sunshine) MIL-STD-810E, method 505.3, proc. II –
MIL-STD-810B, method 505, proc. I – Touch temperature +60 °C (metal),
+68 °C (glass), +85 °C (plastic), +49 °C (metal pushbutton), +69 °C (plastic pushbutton)
MIL-STD-1472D –
Rain (drip) MIL-STD-810E, method 506.3, proc. II – MIL-STD-108E –
Humidity aggravated, +30 °C to +60 °C, 85 % to 95 %
MIL-STD-810E, method 507.3, proc. III,
Fungus resistance MIL-STD-810E, method 508.4
MIL-STD-810B, method 508 – Salt fog aggravated screening MIL-STD-810E, method 509.3, proc. I
MIL-STD-810B, method 509, proc. I – Sand and dust blowing dust MIL-STD-810D, method 510.2, proc. I
MIL-STD-810B, method 510 proc. I – Explosive atmosphere 55 000 ft to ground level, +71 °C MIL-STD-810E, method 511.3, proc. I
MIL-STD-810B, method 511, proc. I – Temperature/humidity/altitude –40/+75 °C, 60 % rel.,
70 000/25 000 ft MIL-STD-810E, method 520.1, proc. III
Temperature/altitude/solar 40 000/60 000/78 000 ft, 883 W/m2
tailored to specific customer program –
Surrounding air pressure 1.04 psia to 21.0 psia, (72 hPa to 1448 hPa)
tailored to specific customer program
Explosive decompression 8 000 ft to 23 000 ft, 77.2 psi/s change rate
MIL-STD-810F, method 500.4, proc IV –
Icing/freezing rain MIL-STD-810E, method 521.1
Version 03.00, July 2013
10 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
Mechanical environment Subject Additional information Applied standard Rem. Loc. Acceleration 13.5 g in all directions (structural) MIL-STD-810E, method 513.4, proc. I –
9 g in all directions (operational) MIL-STD-810E, method 513.4, proc. II – 40 g in all directions (structural) MIL-STD-810B, notice 4, method 513.1,
proc. I –
10 g in all directions (operational) MIL-STD-810B, notice 4, method 513.1, proc. II
–
Vibration Jet aircraft w0 = 0.04 g²/Hz MIL-STD-810E, method 514.4, proc. I,
category 5
w0 = 0.04 g²/Hz
MIL-STD-810B, notice 4, method 514.1, jet –
w0 = 0.025 g²/Hz MIL-STD-810B, notice 4, method 514.1, jet – Propeller aircraft w0 = 0.01 g2/Hz MIL-STD-810E, method 514.4, proc. I,
category 4
Helicopter aircraft w0 = 0.02 g2/Hz MIL-STD-810E, method 514.4, proc. I, category 6, profile UH-60
–
Gunfire wmax = 0.071 g2/Hz MIL-STD-810E, method 519.4 – wmax = 0.0217 g2/Hz, Gpeak = 5.1 g
MIL-STD-810B, notice 4, method 519.1 –
wmax = 0.0657 g2/Hz, Gpeak = 15.3 g
MIL-STD-810B, notice 4, method 519.1 –
Shock Functional shock 20 g, 6 ms to 9 ms MIL-STD-810E, method 516.4, proc. I
15 g, 11 ms MIL-STD-810B, notice 4, method 516.1, proc. I
Crash hazard 40 g, 6 ms to 9 ms MIL-STD-810E, method 516.4, proc. V 40 g, 11 ms MIL-STD-810B, notice 4, method 516.1,
proc. III
Bump 25 g, 6 ms, shock repetition frequency = 1 Hz
EN 60068-2-29
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 11
Electromagnetic compatibility (EMC) Right columns (Rem. and Loc.) point out the applicability where Rem. means the test is applicable for the remote controlled radio R&S®MR6000R and Loc. means the test is applicable for the local controlled transceiver R&S®MR6000L.
Subject Additional information Applied standard Rem. Loc. Conducted emission Power leads 10 kHz to 10 MHz MIL-STD-461D, MIL-STD-462D,
method CE 102 2
Antenna terminal 100 kHz to 8 GHz MIL-STD-461D, MIL-STD-462D, method CE 106
Conducted susceptibility Power leads 30 Hz to 50 kHz
MIL-STD-461D, MIL-STD-462D, method CS 101
Antenna port intermodulation 5 MHz to 650 MHz MIL-STD-461D, MIL-STD-462D, method CS 103
Antenna port rejection of undesired signals
5 MHz to 650 MHz MIL-STD-461D, MIL-STD-462D, method CS 104
Antenna port crossmodulation 5 MHz to 650 MHz MIL-STD-461D, MIL-STD-462D, method CS 105
Bulk cable injection (BCI) test 10 kHz to 400 MHz MIL-STD-461D, MIL-STD-462D, method CS114
Bulk cable injection (BCI) impulse; pulse excitation
MIL-STD-461D, MIL-STD-462D, method CS115
Bulk cable injection (BCI) transient; damped sinusoidal transient
10 kHz to 100 MHz MIL-STD-461D, MIL-STD-462D, method CS116
Radiated emission Electric field 2 MHz to 4 GHz MIL-STD-461D, MIL-STD-462D,
method RE102 2
Radiated susceptibility Electric field 10 kHz to 40 GHz MIL-STD-461D, MIL-STD-462D,
method RS103 aircraft internal
Electrostatic discharge (ESD) ±15 kV, 10 pulses RTCA/DO-160D, sect. 25 – Electric power input characteristics (transient, ripple, steady state, DC voltage)
MIL-STD-704A, cat. B (modified in line with power supply specification)
2 Only in fixed-frequency mode.
Version 03.00, July 2013
12 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
Display color and control panel lighting (applicable for R&S®MR6000L)
Night vision imaging system (NVIS) compatible transceiver Illumination of front panel and keyboard, chromaticity Green A NVIS green A, in line with MIL-L-85762A 3 Illumination of front panel and keyboard, luminance
3.43 Cd/m² ± 1.72 Cd/m², in line with MIL-L-85762A 3
Illumination of front panel and keyboard, NVIS radiance Type I/II, class A and B NRa < 1.7 × 10–10,
NRb < 1.7 × 10–10, scaled to 0.343 Cd/m², in line with MIL-L-85762A 3
Display and status indicators, chromaticity Display green 567 nm dominant wavelength (typ.) Status indicators green 555 nm dominant wavelength (typ.) Display and status indicators, NVIS radiance Type I/II, class A and B NRa < 1.7 × 10–10,
NRb < 1.6 × 10–10, scaled to 0.343 Cd/m², in line with MIL-L-85762A 3
Aviation color compatible transceiver White illuminated control panel Illumination of front panel and keyboard, chromaticity White instrument and panel white, type 1g,
in line with MIL-C-25050 Illumination of front panel and keyboard, luminance White 6.86 Cd/m² ± 3.43 Cd/m²,
in line with MIL-P-7788F Display and status indicators chromaticity Display red 626 nm dominant wavelength (typ.) Status indicators green 555 nm dominant wavelength (typ.)
3 MIL-STD-3009 includes exactly the same technical criteria for class A and class B NVIS compatibility as required by MIL-L-85762.
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 13
Referenced standards Standard Edition/revision and date Title STANAG 4204 edition 2,
May 1988 Technical standard for single channel VHF radio equipment
STANAG 4205 edition 2, May 1988
Technical standard for single channel UHF radio equipment
STANAG 4372 edition 3, April 1999
SATURN – a fast frequency hopping EPM mode for UHF radio
STANAG 4246 edition 3, September 2006
HAVE QUICK UHF EPM communications equipment
MIL-STD-461 MIL-STD-461D, January 1993
Electromagnetic emission and susceptibility requirements for the control of electromagnetic interference
MIL-STD-462 MIL-STD-462D, January 1993
Measurement of electromagnetic interference characteristics
MIL-STD-704 MIL-STD-704A, August 1966
Electric power, aircraft, characteristics and utilization of
MIL-STD-810 MIL-STD-810B, September 1970; MIL-STD-810D, July 1983; MIL-STD-810E, July 1989; MIL-STD-810F, August 2002
Environmental test methods and engineering guidelines
MIL-STD-1472 MIL-STD-1472D, March 1989
Human engineering design criteria for military systems, equipment and facilities
MIL-STD-1553 MIL-STD-1553B, April 1975
Digital time division command/response multiplex data bus
MIL-STD-3009 February 2001 Lighting, aircraft, interior, night vision imaging systems (NVIS) compatible
MIL-L-85762 MIL-L-85762A, August 1988
Military specification: lighting, aircraft, interior, night vision imaging systems (NVIS) compatible
MIL-C-25050 MIL-C-25050A, September 1971
General requirements for color, aeronautical lights and lighting equipment
MIL-P-7788 MIL-P-7788F, November 1992
Panel, information, integrally illuminated
MIL-HDBK-217 MIL-HDBK-217F, notice 2, February 1995
Reliability prediction of electronic equipment
RTCA/DO 160 RTCA/DO 160D, July 1997
Environmental conditions and test procedures for airborne equipment
ICAO Annex 10 Volume V, 2nd edition, July 2001
Aeronautic radio frequency spectrum utilization
DS-102 September 1987 Common fill device interface ICD-GPS-060 revision B,
February 2002 Interface control document for the precise time and time interval (PTTI) interface
ITU-R Recommendation M.489-2 1974/1978/1995 Technical characteristics of VHF radiotelephone equipment operating in the maritime mobile service in channels spaced by 25 kHz
Version 03.00, July 2013
14 Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios
Ordering information Designation Type Order No. R&S®MR6000L (extract of available equipment), ARC-164 housing – local control (alternative illumination on request) Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): fixed frequency; interfaces: RS-485, MIL-STD-1553B trafo coupling; illumination: NVIS (green A); display: green; indicator lights: green; audio output: 150 Ω/600 Ω
R&S® XM6012 Please contact your local Rohde & Schwarz sales office.
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): HAVE QUICK I/II; interfaces: RS-485, MIL-STD-1553B trafo coupling; illumination: NVIS (green A); display: green; indicator lights: green; audio output: 150 Ω/600 Ω
R&S® XM6112
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): R&S®SECOS 5/16 voice and data, HAVE QUICK I/II; interfaces: RS-485, MIL-STD-1553B trafo coupling; illumination: NVIS (green A); display: green; indicator lights: green; audio output: 150 Ω/600 Ω
R&S® XM6412D
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): R&S®SECOS 5/16 voice and data; interfaces: RS-485, MIL-STD-1553B trafo coupling; illumination: NVIS (green A); display: green; indicator lights: green; audio output: 150 Ω/600 Ω
R&S® XM6512D
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): SATURN/HAVE QUICK I/II; interfaces: RS-485, MIL-STD-1553B trafo coupling; illumination: NVIS (green A); display: green; indicator lights: green; audio output: 150 Ω/600 Ω
R&S® XM6912
The following control panel illumination is available for the R&S®MR6000L: 1. Illumination: NVG (green A); display: green; 2. Illumination: white; display: red; 3. Illumination: red; display: red R&S®MR6000R (extract of available equipment), ARC-164 housing – remote control Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): fixed frequency; interfaces: RS-485, MIL-STD-1553B trafo coupling; fill interface; audio output: 150 Ω/600 Ω
R&S®XM6013 Please contact your local Rohde & Schwarz sales office.
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): HAVE QUICK I/II; interfaces: RS-485, MIL-STD-1553B trafo coupling; fill interface; audio output: 150 Ω/600 Ω
R&S®XM6113
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): R&S®SECOS 5/16 voice and data, HAVE QUICK I/II; interfaces: RS-485, MIL-STD-1553B trafo coupling; fill interface; audio output: 150 Ω/600 Ω
R&S®XM6413D
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): R&S®SECOS 5/16 voice and data; interfaces: RS-485, MIL-STD-1553B trafo coupling; fill interface; audio output: 150 Ω/600 Ω
R&S®XM6513D
Frequency bands: 30 MHz to 88 MHz, 108 MHz to 174 MHz, 225 MHz to 400 MHz; EPM (ECCM): SATURN/HAVE QUICK I/II; interfaces: RS-485, MIL-STD-1553B trafo coupling; fill interface; audio output: 150 Ω/600 Ω
R&S®XM6913
Version 03.00, July 2013
Rohde & Schwarz R&S®M3AR MR6000R, R&S®M3AR MR6000L Software Defined Radios 15
Designation Type Order No. Accessories Mating connector sets (R&S®M3AR) Mating Connector for R&S®MR6000L R&S®ZR6000 6085.0215.05 Mating Connector for R&S®MR6000R R&S®ZR6000 6085.0215.07 Trays (R&S®M3AR) Mounting Tray for R&S®MR6000R R&S®KR6010 6131.5426.02 Cooling Tray for R&S®MR6000R R&S®KR6010 6131.5426.03 Service and maintenance tools (R&S®M3AR) Maintenance Connection Box for R&S®MR6000L/R&S®MR6000R
R&S®ZK6000L/R&S®ZK6000R 6131.3681.03
Base Station Adapter for R&S®MR6000L (local control) R&S®BA6000L 6121.6513.02 Base Station Adapter for R&S®MR6000R (remote control) R&S®BA6000R 6121.6520.02 Radio Commander R&S®CP6000 6026.9026.22 PC Maintenance Tool Software R&S®ZS6001 6026.9078.02
The system delivered has the configuration as confirmed in the order.
For product brochure, see PD 0758.1970.12 and www.rohde-schwarz.com
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG
Trade names are trademarks of the owners | Printed in Germany (we)
PD 5214.3223.22 | Version 03.00 | July 2013 | R&S®M3AR MR6000R/L
Subject to change
© 2010 - 2013 Rohde & Schwarz GmbH & Co. KG | 81671 München, Germany
About Rohde & SchwarzRohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solu-tions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established more than 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquar-ters are in Munich, Germany.
Certified Quality System
ISO 9001
Regional contact Europe, Africa, Middle East | +49 89 4129 12345 [email protected]
North America | 1 888 TEST RSA (1 888 837 87 72) [email protected]
Latin America | +1 410 910 79 88 [email protected]
Asia/Pacific | +65 65 13 04 88 [email protected]
China | +86 800 810 8228/+86 400 650 5896 [email protected]
Rohde & Schwarz GmbH & Co. KGwww.rohde-schwarz.com
Environmental commitment Energy-efficient products Continuous improvement in environmental sustainability ISO 14001-certified environmental management system
Service you can rely on Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability
Certified Quality System
AQAP-2110
Certified Quality System
EN 9100
5214322322
M3AR_MR6000RL_dat-sw_en_5214-3223-22_v0300_cover.indd 2 04.07.2013 11:08:17