8/12/2019 RU_07_Norms_02_EN81-71
1/13
8/12/2019 RU_07_Norms_02_EN81-71
2/13
8/12/2019 RU_07_Norms_02_EN81-71
3/13
81-71
EN
Vandal resistant lifts
8/12/2019 RU_07_Norms_02_EN81-71
4/13
81-71
EN
II
.2
The Norm:
Every elevator is used in one way or another, either without problem or mishandled.
Elevators, ones built after EN 81-1and 81-2offer a standardized protection
The norm EN 81-71 entails special measures and security rules about the withstanding protection against vandalism in elevators.Built in, in the areas that are susceptible to vandalism.
The Norm EN 81-71includes either extra or a variation version for the security of the elevator user.
By the given categories the following relevant facts are noted:
The level of usage of the lift
The surrounding area of the lift
The level of which someone is seen, in the neighboring surroundings
Security in the building
Surveillance camera in the elevator
Opening times, to the building and its elevators
The vulnerability to the elevator or its user
The users purpose of the elevator
V ND L RESIST NT LIFTSVANDAL RESISTANT LIFTS
Vandals ToolsElevator category (Class) after EN 81-71
1 2
Pen X X
Rope/Thread/Wire X X
Key X X
Cane X X
Chewing Gum X X
Cigarettes X X
Human weight (75 kg) X X
Lighter X X
Pocket knife (100 mm blade) X X
Medium sized screw driver (length 200 mm) X X
Bottle cap X XSide cutter (medium sized without additional functions) - X
8/12/2019 RU_07_Norms_02_EN81-71
5/13
VII
2.3
81-71
ENCLASS 0
ELEV TOR C TEGORYELEVATOR CATEGORY
Condo-apartment buildings
Shopping centers
Office and management buildings
Normal hotels
Condo-apartment buildings, small amount of units, that are personally owned
Office and management buildings in good areas or with controlled entrances
Normal hotels
Shopping centers with glass elevators
8/12/2019 RU_07_Norms_02_EN81-71
6/13
II
.4
81-71
EN
Apartment buildings with many units, rentals that are in good areas
Office and management buildings with a lot of public traffic and without surveillance of elevators
Low-budget hotels in critical areas
Glass elevators in train stations and at bus stations in nice areas
Non-surveillance elevators in shopping malls in good areasOffice building with a lot of public traffic
Train stations
Shopping centers
CLASS 1
ELEV TOR C TEGORYELEVATOR CATEGORY
8/12/2019 RU_07_Norms_02_EN81-71
7/13
VII
2.5
81-71
EN
Apartment buildings, that are mostly all rentals and that are in social critical areas
All public buildings in social critical areas, without surveillance
Stadiums and public revenues where large crowds turn out
Concert halls
Football stadiums
Large apartment complexes
CLASS 2
ELEV TOR C TEGORYELEVATOR CATEGORY
8/12/2019 RU_07_Norms_02_EN81-71
8/13
II
.6
81-71
EN
1 m
0.2 m
1 kg
Method
SHOCK TESTINGSHOCK TESTING
The test is done with a machine with a weight of 1 kg and a circumference of 10 mm
The press head, is followed out three times from the height of 0,2 m in category 1 and from 1 m in category 2.The test model is placed in an improper point built in the holder frame and then dropped
After the test is carried out, the model has to be in safe and functional working condition
8/12/2019 RU_07_Norms_02_EN81-71
9/13
VII
2.7
81-71
EN
The model is built in, just like in a normal situation that this component is used
The gas lighter with a flame of 40 mm long is placed in the worst possible angle to examine the worst possible outcome.The test model in category 1 is held for 60 seconds through a flame, and 120 seconds in category 2.
After the test, the model has to be in safe and functional working order. The marking must also stay readable.
Method
FIRE TESTINGFIRE TESTING
8/12/2019 RU_07_Norms_02_EN81-71
10/13
II
.8
81-71
EN
Movable
Cover
Spray Head
Tester Counterweight
Direction of arrow being shown(cover removed)
Opening circumference 0,5
Size in mm
Hose
Pressure gaugeFaucet
75,5
30
15
A
300-500
24x15
=360
102
100
15 15
15 6
30` 1
2
x
630`
78
Laboratory test to prove resistance to spray or shower of water,Second index-3, tests for water proof IPX3
This IP-code is used for the protection of the function within the box against hurtful function through the area the water can penetrate. Themodel and the main test are exactly planned out.
Test agent spray hose, with an angle from +/- 180 both sides direct sprays. The maximum distance is from 200 mm.
Water-amount-energy 0, 07 l/mm (+/- 5 %) for every opening in the spray head.
Test time 10 minutes
After the test the model must be in safe and functional working condition.
EN 60529
W TER PROOF TESTINGWATER PROOF TESTING
8/12/2019 RU_07_Norms_02_EN81-71
11/13
VII
2.9
81-71
EN
42
RT 42 wg
RA 42 W wg
EN 81-71 CLASS 1 (IP X3)
COMPONENTSCOMPONENTS
pages J. 2. 29 - J. 2. 53
Front plate removable with the help
of a special tool.
8/12/2019 RU_07_Norms_02_EN81-71
12/13
81-71
ENCLASS
2
II
10
81-71
ENEN 81-71 CLASS 1 AND 2 (IP X3)
COMPONENTSCOMPONENTS
VB 42 M
VB 42
Label black
Label mat
PT 56
PT 28
Faceplate mounting invisible
for the elevator user
8/12/2019 RU_07_Norms_02_EN81-71
13/13
81-71
ENCLASS
2
VII
81-71
ENOMPONENTSCOMPONENTSEN 81-71 CLASS 1 AND 2 (IP X3)
LF 9948 ESG
Flap cover stainless steel
for Key Switch
Lense with security glass (ESG)
For displays and luminous fields
Flap cover stainless steel for key switch
ES42 Vandal-proof behind the faceplate
Desk-shaped fixturewith XL push buttons
ES 42 Vandal-proof