RU_07_Norms_02_EN81-71

Embed Size (px)

Citation preview

  • 8/12/2019 RU_07_Norms_02_EN81-71

    1/13

  • 8/12/2019 RU_07_Norms_02_EN81-71

    2/13

  • 8/12/2019 RU_07_Norms_02_EN81-71

    3/13

    81-71

    EN

    Vandal resistant lifts

  • 8/12/2019 RU_07_Norms_02_EN81-71

    4/13

    81-71

    EN

    II

    .2

    The Norm:

    Every elevator is used in one way or another, either without problem or mishandled.

    Elevators, ones built after EN 81-1and 81-2offer a standardized protection

    The norm EN 81-71 entails special measures and security rules about the withstanding protection against vandalism in elevators.Built in, in the areas that are susceptible to vandalism.

    The Norm EN 81-71includes either extra or a variation version for the security of the elevator user.

    By the given categories the following relevant facts are noted:

    The level of usage of the lift

    The surrounding area of the lift

    The level of which someone is seen, in the neighboring surroundings

    Security in the building

    Surveillance camera in the elevator

    Opening times, to the building and its elevators

    The vulnerability to the elevator or its user

    The users purpose of the elevator

    V ND L RESIST NT LIFTSVANDAL RESISTANT LIFTS

    Vandals ToolsElevator category (Class) after EN 81-71

    1 2

    Pen X X

    Rope/Thread/Wire X X

    Key X X

    Cane X X

    Chewing Gum X X

    Cigarettes X X

    Human weight (75 kg) X X

    Lighter X X

    Pocket knife (100 mm blade) X X

    Medium sized screw driver (length 200 mm) X X

    Bottle cap X XSide cutter (medium sized without additional functions) - X

  • 8/12/2019 RU_07_Norms_02_EN81-71

    5/13

    VII

    2.3

    81-71

    ENCLASS 0

    ELEV TOR C TEGORYELEVATOR CATEGORY

    Condo-apartment buildings

    Shopping centers

    Office and management buildings

    Normal hotels

    Condo-apartment buildings, small amount of units, that are personally owned

    Office and management buildings in good areas or with controlled entrances

    Normal hotels

    Shopping centers with glass elevators

  • 8/12/2019 RU_07_Norms_02_EN81-71

    6/13

    II

    .4

    81-71

    EN

    Apartment buildings with many units, rentals that are in good areas

    Office and management buildings with a lot of public traffic and without surveillance of elevators

    Low-budget hotels in critical areas

    Glass elevators in train stations and at bus stations in nice areas

    Non-surveillance elevators in shopping malls in good areasOffice building with a lot of public traffic

    Train stations

    Shopping centers

    CLASS 1

    ELEV TOR C TEGORYELEVATOR CATEGORY

  • 8/12/2019 RU_07_Norms_02_EN81-71

    7/13

    VII

    2.5

    81-71

    EN

    Apartment buildings, that are mostly all rentals and that are in social critical areas

    All public buildings in social critical areas, without surveillance

    Stadiums and public revenues where large crowds turn out

    Concert halls

    Football stadiums

    Large apartment complexes

    CLASS 2

    ELEV TOR C TEGORYELEVATOR CATEGORY

  • 8/12/2019 RU_07_Norms_02_EN81-71

    8/13

    II

    .6

    81-71

    EN

    1 m

    0.2 m

    1 kg

    Method

    SHOCK TESTINGSHOCK TESTING

    The test is done with a machine with a weight of 1 kg and a circumference of 10 mm

    The press head, is followed out three times from the height of 0,2 m in category 1 and from 1 m in category 2.The test model is placed in an improper point built in the holder frame and then dropped

    After the test is carried out, the model has to be in safe and functional working condition

  • 8/12/2019 RU_07_Norms_02_EN81-71

    9/13

    VII

    2.7

    81-71

    EN

    The model is built in, just like in a normal situation that this component is used

    The gas lighter with a flame of 40 mm long is placed in the worst possible angle to examine the worst possible outcome.The test model in category 1 is held for 60 seconds through a flame, and 120 seconds in category 2.

    After the test, the model has to be in safe and functional working order. The marking must also stay readable.

    Method

    FIRE TESTINGFIRE TESTING

  • 8/12/2019 RU_07_Norms_02_EN81-71

    10/13

    II

    .8

    81-71

    EN

    Movable

    Cover

    Spray Head

    Tester Counterweight

    Direction of arrow being shown(cover removed)

    Opening circumference 0,5

    Size in mm

    Hose

    Pressure gaugeFaucet

    75,5

    30

    15

    A

    300-500

    24x15

    =360

    102

    100

    15 15

    15 6

    30` 1

    2

    x

    630`

    78

    Laboratory test to prove resistance to spray or shower of water,Second index-3, tests for water proof IPX3

    This IP-code is used for the protection of the function within the box against hurtful function through the area the water can penetrate. Themodel and the main test are exactly planned out.

    Test agent spray hose, with an angle from +/- 180 both sides direct sprays. The maximum distance is from 200 mm.

    Water-amount-energy 0, 07 l/mm (+/- 5 %) for every opening in the spray head.

    Test time 10 minutes

    After the test the model must be in safe and functional working condition.

    EN 60529

    W TER PROOF TESTINGWATER PROOF TESTING

  • 8/12/2019 RU_07_Norms_02_EN81-71

    11/13

    VII

    2.9

    81-71

    EN

    42

    RT 42 wg

    RA 42 W wg

    EN 81-71 CLASS 1 (IP X3)

    COMPONENTSCOMPONENTS

    pages J. 2. 29 - J. 2. 53

    Front plate removable with the help

    of a special tool.

  • 8/12/2019 RU_07_Norms_02_EN81-71

    12/13

    81-71

    ENCLASS

    2

    II

    10

    81-71

    ENEN 81-71 CLASS 1 AND 2 (IP X3)

    COMPONENTSCOMPONENTS

    VB 42 M

    VB 42

    Label black

    Label mat

    PT 56

    PT 28

    Faceplate mounting invisible

    for the elevator user

  • 8/12/2019 RU_07_Norms_02_EN81-71

    13/13

    81-71

    ENCLASS

    2

    VII

    81-71

    ENOMPONENTSCOMPONENTSEN 81-71 CLASS 1 AND 2 (IP X3)

    LF 9948 ESG

    Flap cover stainless steel

    for Key Switch

    Lense with security glass (ESG)

    For displays and luminous fields

    Flap cover stainless steel for key switch

    ES42 Vandal-proof behind the faceplate

    Desk-shaped fixturewith XL push buttons

    ES 42 Vandal-proof