64
RUGGEDCOM Modules Catalog For RX5000 06/2018 RC1321-EN-03 Preface Introduction 1 Power Supply Modules 2 Copper Ethernet Modules 3 Fiber Optic Ethernet Modules 4 Serial Modules 5 Control Modules 6 Switch Modules 7 Blank Modules 8

RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Embed Size (px)

Citation preview

Page 1: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM Modules

Catalog

For RX5000

06/2018RC1321-EN-03

Preface

Introduction 1

Power Supply Modules 2

Copper Ethernet Modules 3Fiber Optic EthernetModules 4

Serial Modules 5

Control Modules 6

Switch Modules 7

Blank Modules 8

Page 2: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

ii

Copyright © 2018 Siemens Canada LtdAll rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorizedexcept where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application ortrademark registration.This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may bephotocopied, reproduced or translated to another language without the prior written consent of Siemens Canada Ltd.

Disclaimer Of LiabilitySiemens has verified the contents of this document against the hardware and/or software described. However, deviations between the productand the documentation may exist.Siemens shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing,performance, or use of this material.The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. Weappreciate any suggested improvements. We reserve the right to make technical improvements without notice.

Registered TrademarksRUGGEDCOM™ and ROS™ are trademarks of Siemens Canada Ltd.Linux® is the registered trademark of Linus Torvalds in the United States and other countries.The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on aworld-wide basis.Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of theowner.

Security InformationSiemens provides products and solutions with industrial security functions that support the secure operation of plants, machines, equipmentand/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens' products and solutionsundergo continuous development. Siemens recommends strongly that you regularly check for product updates.For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) andintegrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also beconsidered. For more information about industrial security, visit https://www.siemens.com/industrialsecurity.To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit https://support.automation.siemens.com.

WarrantyFor warranty details, visit https://www.siemens.com/ruggedcom or contact a Siemens customer service representative.

Contacting SiemensAddressSiemens Canada LtdIndustry Sector300 Applewood CrescentConcord, OntarioCanada, L4K 5C7

TelephoneToll-free: 1 888 264 0006Tel: +1 905 856 5288Fax: +1 905 856 1995

[email protected]://www.siemens.com/ruggedcom

Page 3: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Table of Contents

iii

Table of ContentsPreface ............................................................................................................. v

Alerts .................................................................................................................................................. vRelated Documents ............................................................................................................................. viTraining .............................................................................................................................................. viCustomer Support ............................................................................................................................... viOrdering RUGGEDCOM Products .......................................................................................................... vii

Chapter 1Introduction ..................................................................................................... 1

1.1 Available Modules ......................................................................................................................... 21.2 Installing/Removing Modules ......................................................................................................... 61.3 Dimensions .................................................................................................................................. 7

Chapter 2Power Supply Modules ..................................................................................... 9

2.1 RUGGEDCOM RX5000PN PS HI ..................................................................................................... 10

Chapter 3Copper Ethernet Modules ................................................................................ 13

3.1 RUGGEDCOM RX5000PN LM 16TX01 ............................................................................................ 143.2 RUGGEDCOM RX5000PN LM 4CG01 ............................................................................................. 16

Chapter 4Fiber Optic Ethernet Modules .......................................................................... 19

4.1 RUGGEDCOM RX5000PN LM 8FX01 .............................................................................................. 204.2 RUGGEDCOM RX5000PN LM 8FX11 .............................................................................................. 224.3 RUGGEDCOM RX5000PN LM 8FX50 .............................................................................................. 244.4 RUGGEDCOM RX5000PN LM 4FG50 ............................................................................................. 26

Chapter 5Serial Modules ................................................................................................ 29

5.1 RUGGEDCOM RX5000PN LM S01 ................................................................................................. 30

Chapter 6Control Modules ............................................................................................. 33

6.1 RUGGEDCOM RX5000PN CM01 L2SE ............................................................................................ 34

Page 4: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Table of Contents

RUGGEDCOM ModulesCatalog

iv

6.2 RUGGEDCOM RX5000PN CM01 L3SEL2HW ................................................................................... 356.3 RUGGEDCOM RX5000PN CM01 L3SEL3HW ................................................................................... 366.4 RUGGEDCOM RX5000PN CM01 L3SECL2HW .................................................................................. 376.5 RUGGEDCOM RX5000PN CM01 L3SECL3HW .................................................................................. 38

Chapter 7Switch Modules .............................................................................................. 39

7.1 RUGGEDCOM RX5000PN SM 02 ................................................................................................... 407.2 RUGGEDCOM RX5000PN SM 09 ................................................................................................... 427.3 RUGGEDCOM RX5000PN SM 32 ................................................................................................... 447.4 RUGGEDCOM RX5000PN SM 34 ................................................................................................... 467.5 RUGGEDCOM RX5000PN SM 39 ................................................................................................... 487.6 RUGGEDCOM RX5000PN SM 61 ................................................................................................... 507.7 RUGGEDCOM RX5000PN SM 69 ................................................................................................... 51

Chapter 8Blank Modules ................................................................................................ 53

8.1 RUGGEDCOM RX5000PN PS XX .................................................................................................... 548.2 RUGGEDCOM RX5000PN LM Blank ............................................................................................... 55

Page 5: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Preface

Alerts v

PrefaceThis document details RUGGEDCOM power and line modules available for use with devices in the RUGGEDCOMRX5000 series of multi-service routers and switches.It is intended for use by network technical support personnel responsible for the installation, commissioning andmaintenance of routers and switches. It is also recommended for use by network and system planners, systemprogrammers, and line technicians.

CONTENTS• “Alerts”• “Related Documents”• “Training”• “Customer Support”• “Ordering RUGGEDCOM Products”

AlertsThe following types of alerts are used when necessary to highlight important information.

DANGER!DANGER alerts describe imminently hazardous situations that, if not avoided, will result in death orserious injury.

WARNING!WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/orequipment damage.

CAUTION!CAUTION alerts describe hazardous situations that, if not avoided, may result in equipment damage.

IMPORTANT!IMPORTANT alerts provide important information that should be known before performing a procedureor step, or using a feature.

NOTENOTE alerts provide additional information, such as facts, tips and details.

Page 6: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Preface

RUGGEDCOM ModulesCatalog

vi Related Documents

Related DocumentsOther documents that may be of interest include:• RUGGEDCOM RX5000 Installation Guide

https://support.industry.siemens.com/cs/ca/en/view/88895148

TrainingSiemens offers a wide range of educational services ranging from in-house training of standard courses onnetworking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs,experience and application.Siemens' Educational Services team thrives on providing our customers with the essential practical skills to makesure users have the right knowledge and expertise to understand the various technologies associated with criticalcommunications network infrastructure technologies.Siemens' unique mix of IT/Telecommunications expertise combined with domain knowledge in the utility,transportation and industrial markets, allows Siemens to provide training specific to the customer's application.For more information about training services and course availability, visit https://www.siemens.com/ruggedcom orcontact a Siemens Sales representative.

Customer SupportCustomer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or generalinformation, contact Siemens Customer Support through any of the following methods:

OnlineVisit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or checkon the status of an existing SR.

TelephoneCall a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit http://www.automation.siemens.com/mcms/aspa-db/en/automation-technology/Pages/default.aspx.

Mobile AppInstall the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobiledevice and be able to:• Access Siemens' extensive library of support documentation, including FAQs and manuals• Submit SRs or check on the status of an existing SR• Contact a local Siemens representative from Sales, Technical Support, Training, etc.• Ask questions or share knowledge with fellow Siemens customers and the support community

Page 7: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Preface

Ordering RUGGEDCOM Products vii

Ordering RUGGEDCOM ProductsUse the RUGGEDCOM-Selector to select and configure RUGGEDCOM products and accessories. Once selected, anitem(s) can be transferred to the Siemens Industry Mall and ordered.

RUGGEDCOM-Selectorhttp://www.siemens.com/ruggedcom-selector.

For more information, refer to https://www.siemens.com/ruggedcom.

Page 8: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Preface

RUGGEDCOM ModulesCatalog

viii Ordering RUGGEDCOM Products

Page 9: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

1

IntroductionThis catalog details the various power and line modules available for the RUGGEDCOM RX5000. Modules allownetwork designers to quickly and cost effectively adjust their communications infrastructure to the needs of thefacilities and the network.It is intended to be used as a supplement to the Installation Guide for the device:• RUGGEDCOM RX5000 Installation Guide

https://support.industry.siemens.com/cs/ww/en/view/88895148

IMPORTANT!Only qualified personnel should be allowed to install and work on this equipment. Qualified personsin the sense of the safety-related notices in this manual are defined as persons who are authorized tocommission, to ground, and to tag circuits, equipment, and systems in accordance with establishedsafety practices and standards.

CONTENTS• Section 1.1, “Available Modules”• Section 1.2, “Installing/Removing Modules”• Section 1.3, “Dimensions”

Page 10: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

2 Available Modules

Section 1.1

Available ModulesThe following is a list of all power and line modules available for use in the RUGGEDCOM RX5000.

Power Supply ModulesRUGGEDCOM RX5000PN PS HI Specifications

Input Range: 88 to 300 VDC or85 to 264 VACTerminal Type: Screw

Article Numbers6GK6050-0AL13-0AA0(Standard)6GK6050-0AL13-0AA1(Conformal Coated)

Copper Ethernet ModulesRUGGEDCOM RX5000PN LM 16TX01 Specifications

Ports: 16Speed: 100 MbpsInterface: TXPort Type: RJ45Distance: 100 m (328 ft)

Article Numbers6GK6050-0AL20-0NB0(Standard)6GK6050-0AL20-0NB1(Conformal Coated)

RUGGEDCOM RX5000PN LM 4CG01 SpecificationsPorts: 4Speed: 1000 MbpsInterface: TXPort Type: RJ45Distance: 100 m (328 ft)

Article Numbers6GK6050-0AL20-0FC0(Standard)6GK6050-0AL20-0FC1(Conformal Coated)

Fiber Optic Ethernet ModulesRUGGEDCOM RX5000PN LM 8FX01 Specifications

Mode: MMSpeed: 100 MbpsInterface: FXPorts: 8Port Type: STDistance: 2 km (1.2 mi)

Article Numbers6GK6050-0AL20-0BB0(Standard)6GK6050-0AL20-0BB1(Conformal Coated)

RUGGEDCOM RX5000PN LM 8FX11 SpecificationsMode: MMSpeed: 100 MbpsInterface: FXPorts: 8Port Type: LCDistance: 2 km (1.2 mi)

Article Numbers6GK6050-0AL20-0BD0(Standard)6GK6050-0AL20-0BD1(Conformal Coated)

Page 11: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

Available Modules 3

RUGGEDCOM RX5000PN LM 8FX50 SpecificationsSpeed: 100 MbpsInterface: FXSFP Sockets: 8

Article Numbers6GK6050-0AL20-0CU0(Standard)6GK6050-0AL20-0CU1(Conformal Coated)

RUGGEDCOM RX5000PN LM 4FG50 SpecificationsSpeed: 1000 MbpsInterface: LXSFP Sockets: 4

Article Numbers6GK6050-0AL20-0JB0 (Standard)6GK6050-0AL20-0JB1(Conformal Coated)

Serial ModulesRUGGEDCOM RX5000PN LM S01 Specifications

Standard: RS232/RS422/RS485Ports: 8Port Type: DB9

Article Numbers6GK6050-0AL20-0KB0(Standard)6GK6050-0AL20-0KB1(Conformal Coated)

Control ModulesRUGGEDCOM RX5000PN CM01 L2SE Specifications

Layer 2 Standard EditionArticle Numbers6GK6050-0AL30-0AA06GK6050-0AL30-0AA1

RUGGEDCOM RX5000PN CM01 L3SEL3HW SpecificationsLayer 3 Standard Edition, Layer 3hardware

Article Numbers6GK6050-0AL30-0BA06GK6050-0AL30-0BA1

RUGGEDCOM RX5000PN CM01 L3SECL3HW SpecificationsLayer 3 Security Edition, Layer 3Hardware

Article Numbers6GK6050-0AL30-0CA06GK6050-0AL30-0CA1

Page 12: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

4 Available Modules

RUGGEDCOM RX5000PN CM01 L3SEL2HW SpecificationsLayer 3 Standard Edition, Layer 2Hardware

Article Numbers6GK6050-0AL30-0DA06GK6050-0AL30-0DA1

RUGGEDCOM RX5000PN CM01 L3SECL2HW SpecificationsLayer 3 Security Edition, Layer 2Hardware

Article Numbers6GK6050-0AL30-0EA06GK6050-0AL30-0EA1

Switch ModulesRUGGEDCOM RX5000PN SM02 Specifications

Ports: 2Speed: 1000 MbpsInterface: TXPort Type: RJ45Distance: 100 m (328.1 ft)

Article Numbers6GK6050-0AL40-0BA0(Standard)6GK6050-0AL40-0BA1(Conformal Coated)

RUGGEDCOM RX5000PN SM09 SpecificationsSpeed: 1000 MbpsInterface: LXSFP Sockets: 2

Article Numbers6GK6050-0AL40-0JA0 (Standard)6GK6050-0AL40-0JA1(Conformal Coated)

RUGGEDCOM RX5000PN SM32 SpecificationsPorts: 2Speed: 1000 MbpsInterface: TXPort Type: RJ45Distance: 100 m (328.1 ft)

Article Numbers6GK6050-0AL40-0MA0(Standard)6GK6050-0AL40-0MA1(Conformal Coated)

RUGGEDCOM RX5000PN SM34 SpecificationsMode: MMSpeed: 1000 MbpsInterface: SXWavelength: 850 nmPorts: 2Port Type: LCDistance: 500 m (1640 ft)

Article Numbers6GK6050-0AL40-0PA0(Standard)6GK6050-0AL40-0PA1(Conformal Coated)

Page 13: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

Available Modules 5

RUGGEDCOM RX5000PN SM39 SpecificationsSpeed: 1000 MbpsInterface: LXSFP Sockets: 2

Article Numbers6GK6050-0AL40-0UA0(Standard)6GK6050-0AL40-0UA1(Conformal Coated)

RUGGEDCOM RX5000PN SM61 SpecificationsLayer 3/88 Gigabit Throughput,no uplink ports

Article Numbers6GK6050-0AL40-0VA0(Standard)6GK6050-0AL40-0VA1(Conformal Coated)

RUGGEDCOM RX5000PN SM69 SpecificationsLayer 3/88 Gigabit Throughput,2x 10G SFP + Slots Blank

Article Numbers6GK6050-0AL40-0WA0(Standard)6GK6050-0AL40-0WA1(Conformal Coated)

Blank ModulesRUGGEDCOM RX5000PN PS XX Specifications

—Article Numbers6GK6050-0AL10-0AA0

RUGGEDCOM RX5000PN LM Blank Specifications—

Article Numbers6GK6050-0AL20-0AA0

Page 14: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

6 Installing/Removing Modules

Section 1.2

Installing/Removing ModulesAlways refer to the Installation Guide for the RUGGEDCOM RX5000 for instructions on how to install or removea power or line module. The Installation Guide cites important, chassis-specific safety warnings that should befollowed to avoid damage to the module and/or device.Additional installation/removal instructions may also be provided in this Catalog for select modules. Make sure toreview all information provided for a module before installing or removing it.

Page 15: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

Dimensions 7

Section 1.3

DimensionsPower and line modules conform to the following dimensions:

NOTEAll dimensions are in millimeters (mm).

242.

1

180.1

180.1

Figure 1: Power and Line Module Dimensions

Page 16: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

8 Dimensions

Page 17: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 2Power Supply Modules

9

Power Supply ModulesThe following power supply modules are available for the RUGGEDCOM RX5000.

CONTENTS• Section 2.1, “RUGGEDCOM RX5000PN PS HI”

Page 18: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 2Power Supply Modules

RUGGEDCOM ModulesCatalog

10 RUGGEDCOM RX5000PN PS HI

Section 2.1

RUGGEDCOM RX5000PN PS HIThe RUGGEDCOM RX5000PN PS HI power supply module provides high VDC or VAC power to the host device. Itis equipped with a 3-position screw-type terminal block and a failsafe relay terminal block. The module acceptseither AC or DC power inputs from an external power source.

IMPORTANT!The RUGGEDCOM RX5000PN PS HI comes with a safety cover that must be removed to connect powerto the module, and then reinstalled once the wiring is complete.

LEDs indicate when the module is receiving and supplying power.

51 2 43

Figure 2: RUGGEDCOM RX5000PN PS HI1. Negative/Neutral (-/N) Terminal 2. Ground Terminal 3. Positive/Live (+/L) Terminal 4. O LED 5. I LED

LED State Description

O Green The module is supplying power

I Green The module is receiving power

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsCharacteristics

Input Range 88 to 300 VDC or 85 to 264 VAC

Internal Fuse Rating 3.15 A(T)a

Maximum PowerConsumptionb

65 W

Insulation 2800 VDC for 1 minute

Environment

Ingress Protection IP30

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

a (T) denotes time-delay fuse.

b Power consumption varies based on the device configuration.

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Page 19: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 2Power Supply Modules

RUGGEDCOM RX5000PN PS HI 11

Category Standard

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Other NEMA TS 2

Ordering InformationDescription 88-300VDC or 85-264VAC, screw terminal block

Article Numbers 6GK6050-0AL13-0AA0 (Standard)6GK6050-0AL13-0AA1 (Conformal Coated)

Page 20: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 2Power Supply Modules

RUGGEDCOM ModulesCatalog

12 RUGGEDCOM RX5000PN PS HI

Page 21: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

13

Copper Ethernet ModulesThe following copper Ethernet modules are available for the RUGGEDCOM RX5000 series devices.

CONTENTS• Section 3.1, “RUGGEDCOM RX5000PN LM 16TX01”• Section 3.2, “RUGGEDCOM RX5000PN LM 4CG01”

Page 22: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

14 RUGGEDCOM RX5000PN LM 16TX01

Section 3.1

RUGGEDCOM RX5000PN LM 16TX01The RUGGEDCOM RX5000PN LM 16TX01 module features sixteen 10/100 Base-TX RJ45 ports.The module features two dedicated LEDs to indicate link/activity state.

41

2 3

Figure 3: RUGGEDCOM RX5000PN LM 16TX011. Alarm LED 2. Speed LED 3. Link/Activity LED 4. EthernetPorts

LED State Description

Yellow The port is operatingat 1000 Mbps

Speed

Off The port is operatingat 10 or 100 Mbps

Yellow (Solid) Link established

Yellow (Blinking) Activity

Link/Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Pin-Out DescriptionThe following are the pin-out descriptions for the RJ45 ports:

18

Figure 4: RJ45 Ethernet Port Pin Configuration

NamePin

10/100Base-TX 1000Base-TXDescription

1 RX+ BI_DB+ Receive Data+or Bi-Directional

2 RX- BI_DB- Receive Data-or Bi-Directional

3 TX+ BI_DA+ Transmit Data+or Bi-Directional

4 Reserved (Do Not Connect)

5 Reserved (Do Not Connect)

6 TX- BI_DA- Transmit Data-or Bi-Directional

7 Reserved (Do Not Connect)

8 Reserved (Do Not Connect)

Page 23: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

RUGGEDCOM RX5000PN LM 16TX01 15

Technical SpecificationsCharacteristics

Speed 10/100 Mbps

Interface TX

Connector RJ45

Cable Type > CAT-5

Duplex FDX/HDX

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationDescription 16 x 10/100Base-TX RJ45

Article Numbers 6GK6050-0AL20-0NB0 (Standard)6GK6050-0AL20-0NB1 (Conformal Coated)

Page 24: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

16 RUGGEDCOM RX5000PN LM 4CG01

Section 3.2

RUGGEDCOM RX5000PN LM 4CG01The RUGGEDCOM RX5000PN LM 4CG01 module features four 10/100/1000Base-TX copper RJ45 Ethernet ports.

IMPORTANT!This module is only compatible with RUGGEDCOM RX5000PN SM 61 and RUGGEDCOM RX5000PN SM69.

Each port features a dedicated LED that indicates its link/activity state.

2

1 3 3

Figure 5: RUGGEDCOM RX5000PN LM 4CG011. Alarm LED 2. Ethernet Ports 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Pin-Out DescriptionThe following are the pin-out descriptions for the RJ45 ports:

18

Figure 6: RJ45 Ethernet Port Pin Configuration

NamePin

10/100Base-TX 1000Base-TXDescription

1 RX+ BI_DB+ Receive Data+or Bi-Directional

2 RX- BI_DB- Receive Data-or Bi-Directional

3 TX+ BI_DA+ Transmit Data+or Bi-Directional

4 NC BI_DC+ Transmit Data+or Bi-Directional

5 NC BI_DC- Transmit Data+or Bi-Directional

6 TX- BI_DA- Transmit Data-or Bi-Directional

Page 25: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

RUGGEDCOM RX5000PN LM 4CG01 17

NamePin

10/100Base-TX 1000Base-TXDescription

7 NC BI_DA+ Transmit Data-or Bi-Directional

8 NC BI_DA- Transmit Data-or Bi-Directional

Technical SpecificationsCharacteristics

Speed 10/100/1000 Mbps

Interface TX

Connector RJ45

Cable Type > CAT-5

Duplex FDX/HDX

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationDescription 4 x 10/100/1000TX RJ45

Article Numbers 6GK6050-0AL20-0FC0 (Standard)6GK6050-0AL20-0FC1 (Conformal Coated)

Page 26: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

18 RUGGEDCOM RX5000PN LM 4CG01

Page 27: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

19

Fiber Optic Ethernet ModulesThe following fiber optic Ethernet modules are available for the RUGGEDCOM RX5000 series devices.

CONTENTS• Section 4.1, “RUGGEDCOM RX5000PN LM 8FX01”• Section 4.2, “RUGGEDCOM RX5000PN LM 8FX11”• Section 4.3, “RUGGEDCOM RX5000PN LM 8FX50”• Section 4.4, “RUGGEDCOM RX5000PN LM 4FG50”

Page 28: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

20 RUGGEDCOM RX5000PN LM 8FX01

Section 4.1

RUGGEDCOM RX5000PN LM 8FX01The RUGGEDCOM RX5000PN LM 8FX01 module features eight 100Base-FX fiber optic Ethernet ports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 7: RUGGEDCOM RX5000PN LM 8FX011. Alarm LED 2. Ethernet Ports 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOptical Characteristics

Transmit Power -19 to -14 dBm

Receiver Sensitivity -31 dBm

Receiver Saturation -14 dBm

Power Budget 12 dB

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 100 Mbps

Mode MM (Multi-Mode)

Interface FX

Connector ST

Cable Type 62.5/125 μm

Wavelengtha 1300 nm

Nominal Distancea 2 km (1.2 mi)

a Typical.

Page 29: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM RX5000PN LM 8FX01 21

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationDescription 8 x 100FX, Multimode, 1300nm, ST, 2km

Article Numbers 6GK6050-0AL20-0BB0 (Standard)6GK6050-0AL20-0BB1 (Conformal Coated)

Page 30: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

22 RUGGEDCOM RX5000PN LM 8FX11

Section 4.2

RUGGEDCOM RX5000PN LM 8FX11The RUGGEDCOM RX5000PN LM 8FX11 module features eight 100Base-FX fiber optic Ethernet ports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 8: RUGGEDCOM RX5000PN LM 8FX111. Alarm LED 2. Ethernet Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOptical Characteristics

Transmit Power -19 to -14 dBm

Receiver Sensitivity -32 dBm

Receiver Saturation -14 dBm

Power Budget 13 dB

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 100 Mbps

Mode MM (Multi-Mode)

Interface FX

Connector LC

Cable Type 62.5/125 μm

Wavelengthb 1300 nm

Nominal Distancea 2 km (1.2 mi)

b Typical.

Page 31: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM RX5000PN LM 8FX11 23

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationDescription 8 x 100FX, Multimode, 1300nm, LC, 2km

Article Numbers 6GK60500-AL20-0BD0 (Standard)6GK60500-AL20-0BD0 (Conformal Coated)

Page 32: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

24 RUGGEDCOM RX5000PN LM 8FX50

Section 4.3

RUGGEDCOM RX5000PN LM 8FX50The RUGGEDCOM RX5000PN LM 8FX50 module features sockets for up to eight Small Form-factor Pluggable (SFP)transceivers.Each transceiver socket features a dedicated LED that indicates the link/activity state of the associated SFPtransceiver.

2

1 3

Figure 9: RUGGEDCOM RX5000PN LM 8FX501. Alarm LED 2. SFP Transceiver Sockets 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Compatible SFP TransceiversThe following SFP transceivers are compatible with the RUGGEDCOM RX5000. For more information, includinginstallation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog[https://support.industry.siemens.com/cs/ca/en/view/109482309].

IMPORTANT!Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liabilityas a result of performance issues related in whole or in part to third-party components.

SFP Transceiver Connector Type Speed (Mbps) Modec NominalDistance (km)

RUGGEDCOM SFP1121-1FX2 LC 100 MM 2

RUGGEDCOM SFP1131-1FX20 LC 100 SM 20

RUGGEDCOM SFP1131-1FX50 LC 100 SM 50

RUGGEDCOM SFP1131-1FX90 LC 100 SM 90

RUGGEDCOM SFP1132-1BX10R LC 1000 SM 10

RUGGEDCOM SFP1132-1BX10T LC 1000 SM 10

RUGGEDCOM SFP1132-1BX40R LC 1000 SM 40

RUGGEDCOM SFP1132-1BX40T LC 1000 SM 40

RUGGEDCOM SFP1122-1SX LC 1000 MM 0.5

RUGGEDCOM SFP1132-1LX10 LC 1000 SM 10

RUGGEDCOM SFP1132-1LX25 LC 1000 SM 25

Page 33: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM RX5000PN LM 8FX50 25

SFP Transceiver Connector Type Speed (Mbps) Modec NominalDistance (km)

RUGGEDCOM SFP1132-1LX40 LC 1000 SM 40

RUGGEDCOM SFP1132-1LX70 LC 1000 SM 70

RUGGEDCOM SFP1132-1LX100 LC 1000 SM 100c MM = Multi-Mode, SM = Single-Mode

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature Dependent on the installed SFP transceiver.

Ordering InformationDescription 8 x 100FX SFP

Article Numbers 6GK6050-0AL20-0CU0 (Standard)6GK6050-0AL20-0CU1 (Conformal Coated)

Page 34: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

26 RUGGEDCOM RX5000PN LM 4FG50

Section 4.4

RUGGEDCOM RX5000PN LM 4FG50The RUGGEDCOM RX5000PN LM 4FG50 module features sockets for up to four Small Form-factor Pluggable (SFP)transceivers.

IMPORTANT!This module is only compatible with RUGGEDCOM RX5000PN SM 61 and RUGGEDCOM RX5000PN SM69.

Each transceiver socket features a dedicated LED that indicates the link/activity state of the associated SFPtransceiver.

2

1 3

Figure 10: RUGGEDCOM RX5000PN LM 4FG501. Alarm LED 2. SFP Transceiver Sockets 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Compatible SFP TransceiversThe following SFP transceivers are compatible with the RUGGEDCOM RX5000. For more information, includinginstallation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog[https://support.industry.siemens.com/cs/ca/en/view/109482309].

IMPORTANT!Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liabilityas a result of performance issues related in whole or in part to third-party components.

SFP Transceiver Connector Type Speed (Mbps) Moded NominalDistance (km)

RUGGEDCOM SFP1121-1FX2 LC 100 MM 2

RUGGEDCOM SFP1131-1FX20 LC 100 SM 20

RUGGEDCOM SFP1131-1FX50 LC 100 SM 50

RUGGEDCOM SFP1131-1FX90 LC 100 SM 90

RUGGEDCOM SFP1132-1BX10R LC 1000 SM 10

RUGGEDCOM SFP1132-1BX10T LC 1000 SM 10

RUGGEDCOM SFP1132-1BX40R LC 1000 SM 40

RUGGEDCOM SFP1132-1BX40T LC 1000 SM 40

Page 35: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM RX5000PN LM 4FG50 27

SFP Transceiver Connector Type Speed (Mbps) Moded NominalDistance (km)

RUGGEDCOM SFP1122-1SX LC 1000 MM 0.5

RUGGEDCOM SFP1132-1LX10 LC 1000 SM 10

RUGGEDCOM SFP1132-1LX25 LC 1000 SM 25

RUGGEDCOM SFP1132-1LX40 LC 1000 SM 40

RUGGEDCOM SFP1132-1LX70 LC 1000 SM 70

RUGGEDCOM SFP1132-1LX100 LC 1000 SM 100d MM = Multi-Mode, SM = Single-Mode

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature Dependent on the installed SFP transceiver.

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationDescription 4 x 1000LX SFP Blank ( no transceivers )

Article Numbers 6GK6050-0AL20-0JB0 (Standard)6GK6050-0AL20-0JB1 (Conformal Coated)

Page 36: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

28 RUGGEDCOM RX5000PN LM 4FG50

Page 37: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 5Serial Modules

29

Serial ModulesThe following serial modules are available for the RUGGEDCOM RX5000.

CONTENTS• Section 5.1, “RUGGEDCOM RX5000PN LM S01”

Page 38: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 5Serial Modules

RUGGEDCOM ModulesCatalog

30 RUGGEDCOM RX5000PN LM S01

Section 5.1

RUGGEDCOM RX5000PN LM S01The RUGGEDCOM RX5000PN LM S01 module features eight serial DB9 ports that may be used with a null modem(crossover) serial cable.

2

1

Figure 11: RUGGEDCOM RX5000PN LM S011. DB9 Ports 2. Alarm LED

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the host device.

Operating ModesEach serial port can be run in RS232, RS485 or RS422 mode.On initial power-up, all serial ports default to RS485 mode. However, each port can be individually set to RS232,RS485 or RS422 mode via RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guidefor the host device.

Pin-Out DescriptionThe following are the pin-out descriptions for the DB9 connectors:

115

69

Figure 12: DB9 Serial Port

FunctionPin

RS232 Mode RS422 Mode RS485 Mode

1 RX-

2 RX TX+ TX+/RX+

3 TX RX+

4 Reserved (Do Not Connect)

5 COM (Isolated GND)

6 COM (Isolated GND)

7 TX- TX-/RX-

8 Reserved (Do Not Connect)

Page 39: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 5Serial Modules

RUGGEDCOM RX5000PN LM S01 31

FunctionPin

RS232 Mode RS422 Mode RS485 Mode

9 COM (Isolated GND)

Body Chassis GNDa

Screws Chassis GNDa

a Connected internally.

Connecting to RS485 DevicesWhen in RS485 mode, each port in the module can communicate with multiple RS485 devices by wiring devicestogether in sequence over a single twisted pair with transmit and receive signals on the same two wires (halfduplex). For reliable, continuous communication, adhere to the following guidelines:• To minimize the effects of ambient electrical noise, use shielded cabling• The correct polarity must be observed throughout a single sequence or ring• The number of devices wired should not exceed 32, and total distance should be less than 1219 m (4000 ft) at

100 kbps• The Common terminals should be connected to the common wire inside the shield• The shield should be connected to earth ground at a single point to avoid loop currents• The twisted pair should be terminated at each end of the chainThe following illustration demonstrates the recommended RS485 wiring scheme:

< 12

19 m

(40

00 in

)

120Ω 10nF

120Ω 10nF

1

2

3 5

5

6

4

Figure 13: Recommended RS485 Wiring

1. RUGGEDCOM RX5000PN LM S01 Module and Host Device 2. Common (Isolated Ground) 3. Negative 4. Positive 5. Shield to Earth(Connected At a Single Point) 6. RS485 Devices (32 Total)

Page 40: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 5Serial Modules

RUGGEDCOM ModulesCatalog

32 RUGGEDCOM RX5000PN LM S01

NOTEA 15 kΩ pull-up resistor is present on-board for the positive terminal.In noisy environments, additional pull-down resistors may be required for the negative terminal.

Technical SpecificationsCharacteristics

Baud Rate 1200 to 230400 kbps

Connector DB9

Isolation 2.5 kV

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationDescription 8 x RS232/RS422/RS485 DB9 Serial Line Module

Article Numbers 6GK6050-0AL20-0KB0 (Standard)6GK6050-0AL20-0KB1 (Conformal Coated)

Page 41: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 6Control Modules

33

Control ModulesControl modules are the central processing engine for the device. The RUGGEDCOM ROX II operating systemrunning on the module controls and coordinates the functions of all modules installed in the system.Each control module is equipped with an RS232 serial console port for initial management functions, and a locallyconnected 10/100Base-T Ethernet port for system management out-of-band from the switch fabric.Other features include:• Alarm LED to indicate the system status• Removable 1 GB Compact Flash (CF) card, which contains active and fallback installations of the RUGGEDCOM

ROX II operating system, the configuration database, and other system data• A failsafe alarm relay, activated by the operating system to indicate a critical alarm.• A lamp test and alarm cutoff button• A utility USB port for uploading/downloading filesThe following control modules are available for the RUGGEDCOM RX5000.

CONTENTS• Section 6.1, “RUGGEDCOM RX5000PN CM01 L2SE”• Section 6.2, “RUGGEDCOM RX5000PN CM01 L3SEL2HW”• Section 6.3, “RUGGEDCOM RX5000PN CM01 L3SEL3HW”• Section 6.4, “RUGGEDCOM RX5000PN CM01 L3SECL2HW”• Section 6.5, “RUGGEDCOM RX5000PN CM01 L3SECL3HW”

Page 42: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 6Control Modules

RUGGEDCOM ModulesCatalog

34 RUGGEDCOM RX5000PN CM01 L2SE

Section 6.1

RUGGEDCOM RX5000PN CM01 L2SEThe RUGGEDCOM RX5000PN CM01 L2SE control module is pre-configured with RUGGEDCOM ROX II Layer 2Standard Edition installed.

1 3 4 6 7

2 5

Figure 14: RUGGEDCOM RX5000PN CM01 L2SE1. Alarm LED 2. LT/ACO Button 3. MGMT Port 4. USB Port 5. CF Card Slot 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Control module with Layer 2 Standard Edition

Article Numbers 6GK6050-0AL30-0AA0 (Standard)6GK6050-0AL30-0AA1 (Conformal Coated)

Page 43: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 6Control Modules

RUGGEDCOM RX5000PN CM01 L3SEL2HW 35

Section 6.2

RUGGEDCOM RX5000PN CM01 L3SEL2HWThe RUGGEDCOM RX5000PN CM01 L3SEL2HW control module features Layer 2 hardware and is pre-configuredwith RUGGEDCOM ROX II Layer 3 Standard Edition.

1 3 4 6 7

2 5

Figure 15: RUGGEDCOM RX5000PN CM01 L3SEL2HW1. Alarm LED 2. LT/ACO Button 3. MGMT Port 4. USB Port 5. CF Card Slot 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the host device.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Control module with Layer 3 Standard Edition Layer 2 hardware

Article Numbers 6GK6050-0AL30-0DA0 (Standard)6GK6050-0AL30-0DA1 (Conformal Coated)

Page 44: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 6Control Modules

RUGGEDCOM ModulesCatalog

36 RUGGEDCOM RX5000PN CM01 L3SEL3HW

Section 6.3

RUGGEDCOM RX5000PN CM01 L3SEL3HWThe RUGGEDCOM RX5000PN CM01 L3SEL3HW control module features Layer 3 hardware and is pre-configuredwith RUGGEDCOM ROX II Layer 3 Standard Edition.

1 3 4 6 7

2 5

Figure 16: RUGGEDCOM RX5000PN CM01 L3SEL3HW1. Alarm LED 2. LT/ACO Button 3. MGMT Port 4. USB Port 5. CF Card Slot 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Control module with Layer 3 Standard Edition Layer 3 hardware

Article Numbers 6GK6050-0AL30-0BA0 (Standard)6GK6050-0AL30-0BA1 (Conformal Coated)

Page 45: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 6Control Modules

RUGGEDCOM RX5000PN CM01 L3SECL2HW 37

Section 6.4

RUGGEDCOM RX5000PN CM01 L3SECL2HWThe RUGGEDCOM RX5000PN CM01 L3SECL2HW control module features Layer 2 hardware and is pre-configuredwith RUGGEDCOM ROX II Layer 3 Security Edition.

1 3 4 6 7

2 5

Figure 17: RUGGEDCOM RX5000PN CM01 L3SECL2HW1. Alarm LED 2. LT/ACO Button 3. MGMT Port 4. USB Port 5. CF Card Slot 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the host device.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Control module with Layer 3 Security Edition Layer 3 hardware

Article Numbers 6GK6050-0AL30-0EA0 (Standard)6GK6050-0AL30-0EA1 (Conformal Coated)

Page 46: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 6Control Modules

RUGGEDCOM ModulesCatalog

38 RUGGEDCOM RX5000PN CM01 L3SECL3HW

Section 6.5

RUGGEDCOM RX5000PN CM01 L3SECL3HWThe RUGGEDCOM RX5000PN CM01 L3SEL3HW control module features Layer 3 hardware and is pre-configuredwith RUGGEDCOM ROX II Layer 3 Standard Edition.

1 3 4 6 7

2 5

Figure 18: RUGGEDCOM RX5000PN CM01 L3SECL3HW1. Alarm LED 2. LT/ACO Button 3. MGMT Port 4. USB Port 5. CF Card Slot 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Control module with Layer 3 Security Edition Layer 3 hardware

Article Numbers 6GK6050-0AL30-0CA0 (Standard)6GK6050-0AL30-0CA1 (Conformal Coated)

Page 47: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

39

Switch ModulesSwitch modules connect devices together on a computer network by using packet switching to receive, processand forward data to the destination device.The following switch modules are available for the RUGGEDCOM RX5000.

CONTENTS• Section 7.1, “RUGGEDCOM RX5000PN SM 02”• Section 7.2, “RUGGEDCOM RX5000PN SM 09”• Section 7.3, “RUGGEDCOM RX5000PN SM 32”• Section 7.4, “RUGGEDCOM RX5000PN SM 34”• Section 7.5, “RUGGEDCOM RX5000PN SM 39”• Section 7.6, “RUGGEDCOM RX5000PN SM 61”• Section 7.7, “RUGGEDCOM RX5000PN SM 69”

Page 48: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

40 RUGGEDCOM RX5000PN SM 02

Section 7.1

RUGGEDCOM RX5000PN SM 02The RUGGEDCOM RX5000PN SM 02 is a Layer 2/8 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports. It also features two 10/100/1000Base-TX copper RJ45 Ethernetuplink ports.Each port features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 19: RUGGEDCOM RX5000PN SM 021. Alarm LED 2. Ethernet Ports 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Pin-Out DescriptionThe following are the pin-out descriptions for the RJ45 ports:

18

Figure 20: RJ45 Ethernet Port Pin Configuration

NamePin

10/100Base-TX 1000Base-TXDescription

1 RX+ BI_DB+ Receive Data+ orBi-Directional

2 RX- BI_DB- Receive Data- orBi-Directional

3 TX+ BI_DA+ Transmit Data+or Bi-Directional

4 Reserved (DoNot Connect)

BI_DD+ Bi-Directional

5 Reserved (DoNot Connect)

BI_DD- Bi-Directional

6 TX- BI_DA- Transmit Data- orBi-Directional

7 Reserved (DoNot Connect)

BI_DC+ Bi-Directional

Page 49: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM RX5000PN SM 02 41

NamePin

10/100Base-TX 1000Base-TXDescription

8 Reserved (DoNot Connect)

BI_DC- Bi-Directional

Technical SpecificationsCharacteristics

Speed 1 Gbps

Interface TX

Connector RJ45

Cable Type > CAT-5

Duplex FDX/HDX

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Environment

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Layer 2/8 Gigatbit 2 x 10/100/1000TX RJ45

Article Numbers 6GK6050-0AL40-0BA0 (Standard)6GK6050-0AL40-0BA1 (Conformal Coated)

Page 50: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

42 RUGGEDCOM RX5000PN SM 09

Section 7.2

RUGGEDCOM RX5000PN SM 09The RUGGEDCOM RX5000PN SM 09 is a Layer 2/8 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports. It also features two 1000Base-LX fiber optic Ethernet uplinkports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 21: RUGGEDCOM RX5000PN SM 091. Alarm LED 2. SFP Transceiver Sockets 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Compatible SFP TransceiversThe following SFP transceivers are compatible with the RUGGEDCOM RX5000. For more information, includinginstallation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog[https://support.industry.siemens.com/cs/ca/en/view/109482309].

IMPORTANT!Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liabilityas a result of performance issues related in whole or in part to third-party components.

SFP Transceiver Connector Type Speed (Mbps) Modea NominalDistance (km)

RUGGEDCOM SFP1121-1FX2 LC 100 MM 2

RUGGEDCOM SFP1131-1FX20 LC 100 SM 20

RUGGEDCOM SFP1131-1FX50 LC 100 SM 50

RUGGEDCOM SFP1131-1FX90 LC 100 SM 90

RUGGEDCOM SFP1132-1BX10R LC 1000 SM 10

RUGGEDCOM SFP1132-1BX10T LC 1000 SM 10

RUGGEDCOM SFP1132-1BX40R LC 1000 SM 40

RUGGEDCOM SFP1132-1BX40T LC 1000 SM 40

Page 51: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM RX5000PN SM 09 43

SFP Transceiver Connector Type Speed (Mbps) Modea NominalDistance (km)

RUGGEDCOM SFP1122-1SX LC 1000 MM 0.5

RUGGEDCOM SFP1132-1LX10 LC 1000 SM 10

RUGGEDCOM SFP1132-1LX25 LC 1000 SM 25

RUGGEDCOM SFP1132-1LX40 LC 1000 SM 40

RUGGEDCOM SFP1132-1LX70 LC 1000 SM 70

RUGGEDCOM SFP1132-1LX100 LC 1000 SM 100a MM = Multi-Mode, SM = Single-Mode

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature Dependent on the installed SFP transceiver.

Ordering InformationDescription 2x 1000LX SFP Blank ( no transcievers )

Article Numbers 6GK6050-0AL40-0JA0 (Standard)6GK6050-0AL40-0JA1 (Conformal Coated)

Page 52: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

44 RUGGEDCOM RX5000PN SM 32

Section 7.3

RUGGEDCOM RX5000PN SM 32The RUGGEDCOM RX5000PN SM 32 is a Layer 3/8 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports. It also features two 10/100/1000Base-TX copper RJ45 Ethernetuplink ports.Each port features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 22: RUGGEDCOM RX5000PN SM 321. Alarm LED 2. Ethernet Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Pin-Out DescriptionThe following are the pin-out descriptions for the RJ45 ports:

18

Figure 23: RJ45 Ethernet Port Pin Configuration

NamePin

10/100Base-TX 1000Base-TXDescription

1 RX+ BI_DB+ Receive Data+ orBi-Directional

2 RX- BI_DB- Receive Data- orBi-Directional

3 TX+ BI_DA+ Transmit Data+or Bi-Directional

4 Reserved (DoNot Connect)

BI_DD+ Bi-Directional

5 Reserved (DoNot Connect)

BI_DD- Bi-Directional

6 TX- BI_DA- Transmit Data- orBi-Directional

7 Reserved (DoNot Connect)

BI_DC+ Bi-Directional

Page 53: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM RX5000PN SM 32 45

NamePin

10/100Base-TX 1000Base-TXDescription

8 Reserved (DoNot Connect)

BI_DC- Bi-Directional

Technical SpecificationsCharacteristics

Speed 1 Gbps

Interface TX

Connector RJ45

Cable Type > CAT-5

Duplex FDX/HDX

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Environment

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Layer 3/8 Gigatbit 2 x 10/100/1000TX RJ45

Article Numbers 6GK6050-0AL40-0MA0 (Standard)6GK6050-0AL40-0MA1 (Conformal Coated)

Page 54: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

46 RUGGEDCOM RX5000PN SM 34

Section 7.4

RUGGEDCOM RX5000PN SM 34The RUGGEDCOM RX5000PN SM 34 is a Layer 3/8 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports. It also features two 1000Base-SX fiber optic Ethernet uplinkports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 24: RUGGEDCOM RX5000PN SM 341. Alarm LED 2. Ethernet Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOptical Characteristics

Transmit Power -19 to -14 dBm

Receiver Sensitivity -32 dBm

Receiver Saturation -14 dBm

Power Budget 13 dB

Environment

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 1 Gbps

Mode MM (Multi-Mode)

Interface SX

Connector LC

Cable Type 62.5/125 μm

Wavelengthb 1300 nm

Nominal Distancea 2 km (1.2 mi)

b Typical.

Page 55: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM RX5000PN SM 34 47

Ordering InformationDescription 2 x 1000SX, Multimode, 850nm, LC, 500m

Article Numbers 6GK6050-0AL40-0PA0 (Standard)6GK6050-0AL40-0PA1 (Conformal Coated)

Page 56: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

48 RUGGEDCOM RX5000PN SM 39

Section 7.5

RUGGEDCOM RX5000PN SM 39The RUGGEDCOM RX5000PN SM 39 is a Layer 3/8 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports. It also features two 1000Base-LX fiber optic Ethernet uplinkports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 25: RUGGEDCOM RX5000PN SM 391. Alarm LED 2. SFP Transceiver Sockets 3. Port LED

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Compatible SFP TransceiversThe following SFP transceivers are compatible with the RUGGEDCOM RX5000. For more information, includinginstallation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog[https://support.industry.siemens.com/cs/ca/en/view/109482309].

IMPORTANT!Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liabilityas a result of performance issues related in whole or in part to third-party components.

SFP Transceiver Connector Type Speed (Mbps) Modec NominalDistance (km)

RUGGEDCOM SFP1121-1FX2 LC 100 MM 2

RUGGEDCOM SFP1131-1FX20 LC 100 SM 20

RUGGEDCOM SFP1131-1FX50 LC 100 SM 50

RUGGEDCOM SFP1131-1FX90 LC 100 SM 90

RUGGEDCOM SFP1132-1BX10R LC 1000 SM 10

RUGGEDCOM SFP1132-1BX10T LC 1000 SM 10

RUGGEDCOM SFP1132-1BX40R LC 1000 SM 40

RUGGEDCOM SFP1132-1BX40T LC 1000 SM 40

Page 57: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM RX5000PN SM 39 49

SFP Transceiver Connector Type Speed (Mbps) Modec NominalDistance (km)

RUGGEDCOM SFP1122-1SX LC 1000 MM 0.5

RUGGEDCOM SFP1132-1LX10 LC 1000 SM 10

RUGGEDCOM SFP1132-1LX25 LC 1000 SM 25

RUGGEDCOM SFP1132-1LX40 LC 1000 SM 40

RUGGEDCOM SFP1132-1LX70 LC 1000 SM 70

RUGGEDCOM SFP1132-1LX100 LC 1000 SM 100c MM = Multi-Mode, SM = Single-Mode

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature Dependent on the installed SFP transceiver.

Ordering InformationDescription 2x 1000LX SFP Blank ( no transcievers )

Article Numbers 6GK6050-0AL40-0UA0 (Standard)6GK6050-0AL40-0UA1 (Conformal Coated)

Page 58: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

50 RUGGEDCOM RX5000PN SM 61

Section 7.6

RUGGEDCOM RX5000PN SM 61The RUGGEDCOM RX5000PN MSM61 is a Layer 3/88 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports.

1

Figure 26: RUGGEDCOM RX5000PN SM 611. Alarm LED

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Layer 3/88 Gigabit Throughput, no uplink ports

Article Numbers 6GK6050-0AL40-0VA0 (Standard)6GK6050-0AL40-0VA1 (Conformal Coated)

Page 59: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM RX5000PN SM 69 51

Section 7.7

RUGGEDCOM RX5000PN SM 69The RUGGEDCOM RX5000PN SM 69 is a Layer 3/88 Gigabit throughput switch module that enables Gigabitthroughput for up to 24 fiber optic Ethernet ports. It also features sockets for up to two Small Form-factorPluggable (SFP) transceivers.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each transceiver socket features a dedicated LED that indicates the link/activity state of the associated SFPtransceiver.

1

32

Figure 27: RUGGEDCOM RX5000PN SM 691. Port LED 2. Alarm LED 3. Ethernet Ports

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Compatible SFP TransceiversThe following SFP transceivers are compatible with the RUGGEDCOM RX5000. For more information, includinginstallation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog[https://support.industry.siemens.com/cs/ca/en/view/109482309].

IMPORTANT!Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liabilityas a result of performance issues related in whole or in part to third-party components.

SFP Transceiver Connector Type Speed (Mbps) Moded NominalDistance (km)

RUGGEDCOM SFP1121-1FX2 LC 100 MM 2

RUGGEDCOM SFP1131-1FX20 LC 100 SM 20

RUGGEDCOM SFP1131-1FX50 LC 100 SM 50

RUGGEDCOM SFP1131-1FX90 LC 100 SM 90

RUGGEDCOM SFP1132-1BX10R LC 1000 SM 10

RUGGEDCOM SFP1132-1BX10T LC 1000 SM 10

RUGGEDCOM SFP1132-1BX40R LC 1000 SM 40

Page 60: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

52 RUGGEDCOM RX5000PN SM 69

SFP Transceiver Connector Type Speed (Mbps) Moded NominalDistance (km)

RUGGEDCOM SFP1132-1BX40T LC 1000 SM 40

RUGGEDCOM SFP1122-1SX LC 1000 MM 0.5

RUGGEDCOM SFP1132-1LX10 LC 1000 SM 10

RUGGEDCOM SFP1132-1LX25 LC 1000 SM 25

RUGGEDCOM SFP1132-1LX40 LC 1000 SM 40

RUGGEDCOM SFP1132-1LX70 LC 1000 SM 70

RUGGEDCOM SFP1132-1LX100 LC 1000 SM 100

RUGGEDCOM SFP2133-1LR10 LC 10000 SM 10

RUGGEDCOM SFP2133-1ER40 LC 10000 SM 40

RUGGEDCOM SFP2133-1ZR80 LC 10000 SM 80d MM = Multi-Mode, SM = Single-Mode

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationDescription Layer 3/88 Gigabit Throughput, 2x 10G SFP + Slots Blank

Article Numbers 6GK6050-0AL40-0WA0 (Standard)6GK6050-0AL40-0WA1 (Conformal Coated)

Page 61: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 8Blank Modules

53

Blank ModulesThe following blank modules are available for the RUGGEDCOM RX5000 series devices.

IMPORTANT!Blank modules should be installed in empty slots to prevent the ingress of dirt or debris in the chassis.

CONTENTS• Section 8.1, “RUGGEDCOM RX5000PN PS XX”• Section 8.2, “RUGGEDCOM RX5000PN LM Blank”

Page 62: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 8Blank Modules

RUGGEDCOM ModulesCatalog

54 RUGGEDCOM RX5000PN PS XX

Section 8.1

RUGGEDCOM RX5000PN PS XXThe RUGGEDCOM RX5000PN PS XX is a blank module designed to occupy empty power supply module slots in theRUGGEDCOM RX5000 chassis.

Figure 28: RUGGEDCOM RX5000PN PS XX

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Ordering InformationDescription Power Supply Blank Module

Article Numbers 6GK6050-0AL10-0AA0 (Standard)6GK6050-0AL10-0AA1 (Conformal Coated)

Page 63: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

RUGGEDCOM ModulesCatalog

Chapter 8Blank Modules

RUGGEDCOM RX5000PN LM Blank 55

Section 8.2

RUGGEDCOM RX5000PN LM BlankThe RUGGEDCOM RX5000PN LM Blank is a blank module designed to occupy empty line module slots in theRUGGEDCOM RX5000 chassis.

Figure 29: RUGGEDCOM RX5000PN LM Blank

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM RX5000.

Ordering InformationDescription Blank Module

Article Numbers 6GK6050-0AL20-0AA0 (Standard)6GK6050-0AL20-0AA1 (Conformal Coated)

Page 64: RUGGEDCOM Modules Copper Ethernet Modules 3 4 5 6 7 · 2.1 RUGGEDCOM RX5000PN PS HI ... Copper Ethernet Modules ... Siemens offers a wide range of educational services ranging from

Chapter 8Blank Modules

RUGGEDCOM ModulesCatalog

56 RUGGEDCOM RX5000PN LM Blank