SAINT PAUL SUSTAINABLE BUILDING POLICY
Training Module SixIndoor environmental quality
requirements
Saint PaulSustainable Building Policy
SAINT PAUL SUSTAINABLE BUILDING POLICY
Indoor environmental quality
• Background– Ventilation – Construction indoor air quality– Low emitting materials– Thermal comfort
• General reporting requirements• Requirements for specific rating systems
SAINT PAUL SUSTAINABLE BUILDING POLICY
BACKGROUND
SAINT PAUL SUSTAINABLE BUILDING POLICY
Background• Indoor environmental quality (IEQ) is an essential
part of providing a healthy and comfortable environment for residents and employees.
• The Saint Paul Overlay has four indoor environmental quality sections:– Ventilation requirements– Construction Indoor Air Quality (IAQ)
management plan– Selection of low-emitting materials– Thermal comfort
SAINT PAUL SUSTAINABLE BUILDING POLICY
Ventilation requirements
• Exhaust pollutants• Mitigate negative health effects• Manage moisture
SAINT PAUL SUSTAINABLE BUILDING POLICY
Construction IAQ management
• Manage dust and pollutants created during the construction process.
• Minimize exposure to construction hazards both to the occupants of the building and workers during construction.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Low-emitting materials
• Limit the amount of pollutants entering the indoor environment.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Thermal comfort
• Thermal comfort requirements set limits on radiant temperature, air temperature, and humidity, based on building type and a variety of other factors.
• Intended to provide a comfortable indoor environment for most occupants.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Specific requirements: Indoor environmental quality• ASHRAE standards 62.1 and 62.2– Define appropriate rates of ventilation– Commonly incorporated into sustainable building
standards
SAINT PAUL SUSTAINABLE BUILDING POLICY
Specific requirements: Construction IAQ Management
• During-construction: – Establish a plan of construction IAQ management– For buildings occupied while under construction,
follow the SMACNA IAQ guidelines– Includes specific requirements if not outlined in
guideline or rating system• Post-construction IAQ management: requires
a pre-occupancy “Building Flush Out” period
SAINT PAUL SUSTAINABLE BUILDING POLICY
Specific requirements: Low-emitting materials
• Limit the amount of Volatile Organic Compounds (VOCs) including formaldehyde present in building materials.– Primarily achieved through product selection,
typically of paints, adhesives, wood products, carpet and other interior finishes.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Specific requirements: Thermal Comfort
• ASHRAE Standard 55– Defines the range of indoor thermal
environmental conditions acceptable to a majority of occupants.
SAINT PAUL SUSTAINABLE BUILDING POLICY
GENERAL REPORTING REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
General reporting requirements: Ventilation
• Use the Indoor Environment Quality Worksheet found at: – www.sustainablebuildingpolicy.umn.edu/saintpaul
• Include a list of spaces found in the project, their required ventilation rates per ASHRAE 62 and the ventilation rate as designed.
• Submit the completed Worksheet to DSI and PED
SAINT PAUL SUSTAINABLE BUILDING POLICY
General reporting requirements: Construction IAQ management Plan• Submit the required IAQ construction
management plan.– Indicate in bid and construction documents that
compliance with the Construction Indoor Air Quality Management Plan is required.
– The Template for construction IAQ management plan is available at www.sustainablebuildingpolicy.umn.edu/saintpaul
– Submit completed plan to DSI and PED
SAINT PAUL SUSTAINABLE BUILDING POLICY
General reporting requirements: Low-emitting materials requirements• List the products which have been specified for the
the project, along with product type and and method of verification of compliance ( please list the database of compliant materials in which the product appears, or the certification that the product has recieved).– Template for Materials Selection Log available at
www.sustainablebuildingpolicy.umn.edu/saintpaul– Required for products listed under each rating system, specific
requirements vary.– Submit completed log to DSI and PED
SAINT PAUL SUSTAINABLE BUILDING POLICY
General reporting requirements: Thermal comfort• List all spaces in the building, their designed high and low
temperature set points during occupancy, air speed and relative humidity, verifying that they are within the required comfort zone for compliance with ASHRAE 55. For spaces where mean radiant temperature or other indoor comfort factor may be an issue, list strategies to maintain indoor surface temperatures within 20 degrees Fahrenheit and mitigate other comfort factors.– Template available at
www.sustainablebuildingpolicy.umn.edu/saintpaul - note that this is a shared template with the ventilation requirement.
SAINT PAUL SUSTAINABLE BUILDING POLICY
REQUIREMENTS FOR SPECIFIC RATING SYSTEMS
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
N.C
. 2
00
9
LEED N.C. 2009 IEQ REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
N.C
. 2
00
9Ventilation requirements
• Achieve IEQ Prerequisite 1: Minimum indoor air quality performance.
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
N.C
. 2
00
9Construction IAQ management plan requirements• Achieve IEQ Credit 3.1 and 3.2: Construction
IAQ Management Plans, both During Construction and Before Occupancy for 2 points total.
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
N.C
. 2
00
9Low-emitting materials requirements
• Achieve IEQ Credits 4.1, 4.2, 4.3, 4.4: Low-Emitting Materials for 4 points total.
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
N.C
. 2
00
9Thermal comfort requirements
• Achieve IEQ Credit 7.1: Thermal Comfort for 1 point.
SAINT PAUL SUSTAINABLE BUILDING POLICY
GB
I -
Gre
en G
lobes
GBI - GREEN GLOBESIEQ REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
GB
I -
Gre
en G
lobes
Ventilation requirements
• Achieve 10 points for credit 12.1.1.1.
SAINT PAUL SUSTAINABLE BUILDING POLICY
GB
I –
Gre
en G
lobes
Construction IAQ management plan
• Achieve 4 points for credit 6.2.4.1 and 5 points for credit 6.2.4.2. And
• Meet construction air quality requirements of SMACNA IAQ Guideline for Occupied Buildings under Construction. Requirements include elements for IAQ protection during construction. See the Saint Paul Overlay to the Sustainable Building Policy for more information.
SAINT PAUL SUSTAINABLE BUILDING POLICY
GB
I -
Gre
en G
lobes
Low-emitting material requirements
• Achieve 8 points for credit 12.2.1.1: Volatile Organic Compounds.
SAINT PAUL SUSTAINABLE BUILDING POLICY
GB
I -
Gre
en G
lobes
Thermal comfort requirements
• Achieve 10 points from section 12.5.2.1: Thermal comfort design.
SAINT PAUL SUSTAINABLE BUILDING POLICY
B3
- M
inn
eso
ta S
ust
ain
ab
le
Bu
ildin
g G
uid
elin
es
B3-MINNESOTA SUSTAINABLE BUILDING GUIDELINES IEQ REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
B3
- M
inn
eso
ta S
ust
ain
ab
le
Bu
ildin
g G
uid
elin
es
Ventilation requirements
• Achieve required MSBG criteria I.4.
SAINT PAUL SUSTAINABLE BUILDING POLICY
B3
- M
inn
eso
ta S
ust
ain
ab
le
Bu
ildin
g G
uid
elin
es
Ventilation requirements
SAINT PAUL SUSTAINABLE BUILDING POLICY
B3
- M
inn
eso
ta S
ust
ain
ab
le
Bu
ildin
g G
uid
elin
es
Construction IAQ management plan
• Achieve required MSBG criteria P.4.
SAINT PAUL SUSTAINABLE BUILDING POLICY
B3
- M
inn
eso
ta S
ust
ain
ab
le
Bu
ildin
g G
uid
elin
es
Low-emitting material requirements
• Achieve required MSBG criteria I.2.
SAINT PAUL SUSTAINABLE BUILDING POLICY
B3
- M
inn
eso
ta S
ust
ain
ab
le
Bu
ildin
g G
uid
elin
es
Thermal comfort requirements
• Achieve required MSBG criteria I.5, including optional section E.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
MINNESOTA GREEN COMMUNITIESIEQ REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
Ventilation requirements
• Achieve mandatory credit 7-6, installing a ventilation system that supplies fresh air per ASHRAE 62.1 - 2007.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
Construction IAQ management plan
• Minnesota Green Communities does not have a satisfactory ventilation criterion. Instead meet Sections 1 and 2 of the following guidelines, when applicable:
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
Construction IAQ management plan – section 1
• Comply with a pre-occupancy building flush-out as described in LEED N.C. Version 2.2.
• Total air volume of 14,000 cu. ft. of outdoor air per sq. ft. of floor area
• 60 degrees temperature• 60% maximum relative humidity• Replace all filtration media prior to occupancy
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
Construction IAQ management plan – section 2
• Meet construction air quality requirements of SMACNA IAQ Guideline for Occupied Buildings under Construction.
• Maintain ventilation continuously during installation.
• Ventilate areas directly to outside.• During dust-producing activities (e.g., drywall
installation and finishing, and transportation and delivery), turn ventilation system off.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
Low-emitting material requirements
• Achieve required credits 7-1, 7-2, 7-3 and 7-4
SAINT PAUL SUSTAINABLE BUILDING POLICY
Gre
en C
om
munit
ies
Thermal comfort requirements
• Meet the requirements of ASHRAE Standard 55–2004: Thermal Comfort Conditions for Human Occupancy.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Min
neso
ta G
reenSta
r
MINNESOTA GREEN STARIEQ REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
Min
neso
ta G
reenSta
rVentilation requirements
• Achieve Section 5A-PR1
SAINT PAUL SUSTAINABLE BUILDING POLICY
Min
neso
ta G
reenSta
rConstruction IAQ management plan
• Satisfy overall requirement OPR-4• Achieve 3 points for section 8F-1
SAINT PAUL SUSTAINABLE BUILDING POLICY
Min
neso
ta G
reenSta
rLow-emitting material requirements
• At a minimum, achieve credits in the following categories:8A-3c, 8A-3f, 8A-6d, 8B-5, 8B-9d, 8C-2d, 8C-5d, 8D-2d, 8E-2 (for no-added urea formaldehyde), 8E-3, 8F-2, 8F-3.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Min
neso
ta G
reenSta
rThermal comfort requirements
• Meet the requirements of ASHRAE Standard 55–2004: Thermal Comfort Conditions for Human Occupancy.
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
for
Hom
es
LEED FOR HOMESIEQ REQUIREMENTS
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
for
Hom
es
Ventilation requirements
• Achieve required criteria for Indoor Environmental Quality (EQ) credit 4.1: Basic Outdoor Air Ventilation.
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
for
Hom
es
Construction IAQ management plan
• Achieve at least 1 point each for the following:– EQ credit 8.1 Indoor contaminant control during
construction– EQ credit 8.2: Indoor contaminant control– EQ Credit 8.3: Preoccupancy flush
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
for
Hom
es
Low-emitting material requirements
• Achieve all possible points in section Materials and Resources (MR) 2.2 by achieving low-emissions standards for Environmentally Preferable Products.
SAINT PAUL SUSTAINABLE BUILDING POLICY
LEED
for
Hom
es
Thermal comfort requirements
• Achieve at least 1 point for EQ 6: Distribution of Space Heating and Cooling.
SAINT PAUL SUSTAINABLE BUILDING POLICY
Questions?