Upload
others
View
10
Download
0
Embed Size (px)
Citation preview
COMMERCIAL EQUIPMENTS
Web: www.commercialequipments.in E-mail: [email protected]
Salt Spray ChamberSalt Spray ChamberSalt Spray ChamberSalt Spray Chamber
Salt Spray Chamber for salt fog testing and corrosion
testing in salt laden atmosphere. Temperature Range:
From room temperature to 35°C +/-2deg.C. Humidity
Range: Up to saturation limit. Control of: Digital Readout
of set and actual values. Temperature Testing Chamber:
Acrylic Glass of 8 mm thickness, Nozzle made of Acrylic
plastic. Heating: SS Heating Element, 0.75 kW, 220V
single phase AC, fitted in the salt solution tank. Solution
Tank: Made of Fibre Glass, Double walled capacity 35
litres approximately with provision for water level.
Chamber Stand: Made of MS Angle. Unit is supplied with
Stainless Steel rods and hooks for hanging samples. It is
designed to deliver compressed air at a pressure up to 1
kg/cm². Suitable for operation for 220 V, 50 Hz, Single
Phase, AC supply.
Salt Salt Salt Salt Cass/Fog Test Cass/Fog Test Cass/Fog Test Cass/Fog Test ChamberChamberChamberChamber
As per ISO 7253:1984, ISO 7253:1984, ISO 7253:1984, ISO 7253:1984, IS – 101 (Part 6/Sec 1 – June 1997),
IS – 9000, IS – 6910, ISO – 3768 Part-I, ASTM – B – 117 –
73, ASTM – B – 368, DIN – 50021, JIS – 2371
The updated models of Salt/Cass Fog Test Chamber
specially designed for evaluating the corrosion resistance
of the surface treatment of metallic materials by Copper
Accelerated Acetic Acid Salt Spray Test Method.
Flow CupFlow CupFlow CupFlow Cup Flow Cup No. 4 with or w/o
NABL calibration certificate.
Simple flow cup of the efflux type
is used for approximate
measurements of apparent
viscosity for control of consistency
during manufacture and use of
paints, lacquers and viscous products
Flow cups with protective skirt
are made from gun metal with stainless steel orifice and
are equivalent to Type B cups. Each cup is supplied
complete with a stand having leveling screws.
PycknometerPycknometerPycknometerPycknometer
(Weight per 10Ltr Cup)(Weight per 10Ltr Cup)(Weight per 10Ltr Cup)(Weight per 10Ltr Cup)
Weight Per 10Ltr cup (Pycknometer) to be used for Liquid
Paint. Made from stainless steel.
Scratch Hardness Tester,Scratch Hardness Tester,Scratch Hardness Tester,Scratch Hardness Tester, Hand Operated. Cap.: 5KgHand Operated. Cap.: 5KgHand Operated. Cap.: 5KgHand Operated. Cap.: 5Kg
This is a suitable apparatus for carrying out test relating
to resistance to scratching under a specified load of a
dried film of the paint and is used I testing paints,
varnish, lacquer and related products. This is most
suitable for research work or for longer laboratory and
industries where repetitive quality control tests are
carried out.
COMMERCIAL EQUIPMENTS
Web: www.commercialequipments.in E-mail: [email protected]
Cross Cut TesterCross Cut TesterCross Cut TesterCross Cut Tester
Cross Cut Tester, Made of Harden Steel, fitted with well
finished wooden handle and easy operation. Head cross
head a four side cut head. Each head has 10 slots.
A. 1mm Head
B. 2mm Head
Tubular Impact TesterTubular Impact TesterTubular Impact TesterTubular Impact Tester
A. Tubular Impact Tester, fall of 2lbs weight from 63.5cm
Height . Suitable for Liquid Paint only B. Tubular Impact
Tester, fall of 2lbs weight from 63.5cm Height and 2kg
Weight From 1.2mtr heights suitable for Liquid Paint as
well as Powder Coating Paint
Corrosion ChamberCorrosion ChamberCorrosion ChamberCorrosion Chamber
As Per IS:101. Suitable For Temperature Range Between
42deg.C. To 48deg.C. Inside Chamber made of Stainless
Steel and out side Stainless Steel. Unit is fitted with
Digital Temperature Controller-cum-Indicator and Digital
Timer. Size: 355 x 355 x 355mm
Color Matching CabinetColor Matching CabinetColor Matching CabinetColor Matching Cabinet
Multi Light Color Matching Cabinet is used for visual
colour matching under different light sources i.e.
:Artificial Daylight, Tungsten Filament Light, Ultra Violet
Light & I. R. Light
Digital Coating GaugeDigital Coating GaugeDigital Coating GaugeDigital Coating Gauge
Use for single type of pannel Ferrous OR Non-Ferrous.
Range : 0 to 600 Microns.
01. Coatmeasure – M : measure non-magnetic coating on
Magnetic base. It is ideal for coatings on M. S. (Ferrous
base)
02. Coatmeasure – C measures thickness of Non-
conductive coating on conductive base.
COMMERCIAL EQUIPMENTS
Web: www.commercialequipments.in E-mail: [email protected]
Hegman GaugeHegman GaugeHegman GaugeHegman Gauge
Double slot, Steel
Digital Gloss MeterDigital Gloss MeterDigital Gloss MeterDigital Gloss Meter
45 or 60deg Head
Gloss of the surface is the ratio of light reflected from the
surface of the sample to the light incident on it, when the
angle of incidence and reflectance are equal numerically
but opposite in sigh i.e. Gloss is a measure of how well
the surface functions as a mirror. Gloss increased as the
angle of incidence increases. The unit is lightweight and
with a inbuilt measuring head having, integral readout
unit, with controls for setting the value of standards and
holding the displayed value. In addition, there is an
averaging facility to allow for surface variations.
Flexibility TesterFlexibility TesterFlexibility TesterFlexibility Tester
The apparatus consists of two plates hinged at one end
with the help of a mandrel. The mandrel has free
movement on the centre rod fixed with nuts on outer
sides of the hinges. The painted panel is bent through
180° when the plates are folded on the hinges. A stop
brass spacer is provided on one plate.
A magnifier with X10 magnification is provided along with
the apparatus to study the film after bending round the
mandrel.
Conical MandrelConical MandrelConical MandrelConical Mandrel
The conical mandrel may be used to establish two
properties of a coating; its resistance to cracking and/or
detachment from its substrate and its elongation during
the test. This is accomplished by bending the test
material around a conically shaped metal bar.
It is suitable for use with metal panels up to 0.8mm thick
(flexible substrates up to 5mm in thickness) e.g.
polythene or synthetic rubber. The apparatus consists of
a steel mandrel 203mm in length and tapering from
38mm to 3mm in diameter. It will accommodate test
panels up to 19cm x 11cm in size. A graduated scale on
the clamping bar indicates the mandrel diameter at
which failure has occurred. When this diameter is added
to the thickness of the panel used, the percentage
elongation can be calculated.