Sanrad-XinAo MDT
Centauri 0.30T MRI System
Super Open
Magnetic Resonance Imaging System
Wide bore ,Patient friendly .
In house music
Adopts Dynamic balancing
technology.
Best homogeneity ,<.9ppm.
Sanrad
Powerful Gradient System Gradient coil/ Amplifier
–Maximum gradient strength 18T/m ensure
high special resolution
–Rising time 600μs( up to 98%)
–Slew rate 55mT/m/ms increase the
scanning speed
Thin slice thickness and less scan time.
Comprehensive Receiving coils
7 standard Coil configuration:QD Head coil QD Neck Coil QD Body Coil
QD Extremity CoilSpine CoilShoulder coil
Abundant Imaging Sequences
Spin Echo /FSE
Gradient Echo ( GE)
IR, FLAIR, STIR
MSME
MRA/MRV
SS FSE
MRU,MRCP)
DWI/ADC Mapping
Advanced Imaging Techniques
Multi-slice/Multi-angle
Gating Technology
Partial echo
Flow compensation
Anti-wrap-around artifact elimination
Multi-region pre-saturation
Optimized bandwidth
Optimized data acquisition
In house music systems
Features of MRI
Non-invasive examination
Multi-type of images
High image contrast
Slicing at any orientation
No contrast agent required in
MRA/MRV/MRU
Multi-type of images
To get more diagnosis information by comparing various
images
To improve diagnostic confidence and detection rate.
T1 imageFLAIR Image
T2 Images
GRE Images
Slicing at any orientationAxial Sag Coronal
No Contract Agent Need in MRA
In-flow and out-flow effect
3D and 2DTOF
MRI Clinical Applications
Nervous system
Spine ,extremity
Muscle,Soft tissue
Angiography system
Abdomen/MRCP/ Pelvis
Head
Clinical Applications
Post Contrast with MTC
Brain Infarct demonstrated by Diffusion
Coronal T1
Clinical Applications
Small Brain lesions like Pitutory,optic lesions
Spine and Spinal Cord
Clinical Applications
T1 T2 STIR
Clinical Applications
D Spine T2,T1 sag & axial
C SPINE
Clinical Applications
Extremity ,Joint
Clinical Applications
PD IMAGE STIR IMAGE
Clinical Applications
•Small Extremity,Shoulder,wrist.
Pelvis
Clinical Applications
Clinical Applications
Body Morphology.
Spin Echo ( SE)
.
Bread and Butter
sequence
Clear image
For anatomic details
Gives Good T1 wt contrast
Fast Spin Echo (FSE)
Used for T2 contrast. For better pathological details.
Gradient Echo (GE) Fast image acquisition
Sensitive to bleeding
T2 Images
IR , FLAIR
Water Suppressed
Infarct/ tumor displayed
better
Judge focal composition
IR, STIR
Fat suppression signal
Judge focus composition
Other parts displayed much clearer
MRA
Carotid MRA
Angio without contrast
2D/3D TOD
MOSTE
MTContrast
MIP projection
arterio and venogramme displayed
Venogramme
MRCP , MRU
Bile duct Obstruction
MRCP and MRU
–Magnetic Resonance
Cholangiopancreatography
(MRCP)
–Magnetic Resonance Urograpgy
(MRU)
–Magnetic Resonance
Myelography (MRM)
THANK YOU
Anantha Padmanabha