Single Family Dwelling

Alabama Building Inspection Services LLCP.O. Box 414Saraland, Alabama 36571

Chunchula Al , 36521

Page 2: Saraland, Alabama 36571 P.O. Box 414

Table of Contents Definitions 2

General Information 2

Lots and Grounds 6

Exterior 6

Roof 8

Garage 9

Electrical 10

Structure 11

Crawl Space 12

Air Conditioning 13

Fireplace 13

Heating System 14

Plumbing 14

Bathroom 15

Kitchen W/Eat-in Breakfast Nook 16

Bedroom 17

Living Space 18

Laundry Room/Area 19

Summary 20

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 1 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 3: Saraland, Alabama 36571 P.O. Box 414

DefinitionsNOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection

A Acceptable Functional with no obvious signs of defect. NP Not Present Item not present or not found. NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at

time of inspection. M Marginal Item is not fully functional and requires repair or servicing. D Defective Item needs immediate repair or replacement. It is unable to perform its intended function.

General Information2V Geodesic Dome House

Inspector Name: Jim Pinion Company Name: Alabama Building Inspection Services LLC Address: P.O. Box 414 City State Zip: Saraland, Alabama 36571

Client Name: Address: Out of State City, State Zip:

Property Address: City State Zip: Chunchula, Alabama 36521

IMPORTANT AGREEMENTS AND LIMITATIONS SPECIAL NOTE: THE FOLLOWING IS NOT INCLUDED IN THIS INSPECTION: 1. WATER OR AIR QUALITY 2. PRESENCE OF TOXIC OR CARCINOGENIC MATTER EMITTED FROM THE GROUND, BUILDING MATERIALS, IN WATER OR AIR SUPPLY OR FROM THE OPERATION OF ANY EQUIPMENT 3. ITEMS THAT ARE OBSTRUCTED, INACCESSIBLE OR NOT IN PLAIN VIEW. - The Client is hereby informed that structural and mechanical insurance is available for a nominal fee from insurance companies. Your real estate agent may be able to help you with obtaining structural or mechanical insurance coverage. The client understands that the Comments and Notations made on this report are subjective opinion of the inspector based on observations at the time of inspection.

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 2 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 4: Saraland, Alabama 36571 P.O. Box 414

General Information (Continued)Therefore, the INSPECTOR desires it be clearly understood he offers NO WARRANTY concerning future operation or condition of any item inspected - OR - that all defects of such items were observed at the time of inspection and noted on the report. THEREFORE, the INSPECTOR does not imply that he warrants or guarantees any item regardless whether they were inspected or reported. 1. What We Do: a. All inspections are performed in accordance with Standards of Practice. The inspection is of conditions which are present and visible at the time of the inspection. All mechanical and electrical equipment, systems, and appliances are operated in normal modes and operating range at the time of the inspection. b. We shall observe, render an opinion and report which of the parts, components and systems are not functioning at the time of the inspection or are in need of repair and report on visible existing or recognized hazards. c. If you have questions, we will explain what we saw about the item. 2. What We Do Not Do: a. We do not make guarantees, warranties, representations, or insure the future performance or condition of any item. If you want a warranty, guarantee, or insurance policy, you must obtain it from a warranty or insurance company. Please remember that almost every item in any pre-owned home is in used condition and has ordinary wear and tear, and all houses will change and deteriorate in the future. WE DISCLAIM ALL OTHER WARRANTIES. b. We do not inspect any item which we cannot see in a normal inspection. For example, we do not move furniture, rugs, carpet, paintings, appliances or other furnishings in performing an inspection. We do not uncover buried pipes or items. We cannot see items covered by wallpaper, flooring or plants. Repairs or remodeling may hide evidence of prior damage or defects. We do suggest that you ask the seller about repairs that are covered up or any previous problems because we DO NOT report on past conditions that appear corrected. We do not inspect for latent defects, therefore, you should obtain a copy of the sellers disclosure statement. c. We do not inspect for building codes, soil analysis, adequacy of design, capacity, efficiency size, value, floor plain location, pollution, habitability, environmental hazards such as asbestos, UFFI, EMF, lead base paint, etc. Please remember older buildings do not meet the same standards as newer buildings, even though items in both may perform the function for which they are intended. d. We do not allow the inspector to change or add to these printed provisions in any way. e. We do not hold ourselves to be specialists for any particular item or engineers. We are a general real estate improvement inspection company. If we report an item is not performing its intended function, needs repair, or shows evidence of prior damage, we urge you to have that item examined by a specialist before purchasing the house. We do not and cannot give cost estimates to repair any item. 3. What You Must Do: a. If you have any complaints about our inspection, you must notify us in writing within seven days after you discovered any problem, and allow us to re-inspect before changing the condition on the item, except in an emergency.

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 3 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 5: Saraland, Alabama 36571 P.O. Box 414

General Information (Continued)b. If we report an item is in need of immediate repair, or is not performing its intended function or shows past damage and you intend to purchase the property anyway; you should first have the item re-inspected by a specialist in that field (i.e. foundation - structural engineer//plumbing - plumber). c. You agree that, to the extent allowed by law, any damages for breach of this contract or report are limited to the amount of the inspection fee only. d. If you sue on this inspection, but do not prevail, you agree to pay all our reasonable attorneys fees. e. You represent to us that (1) the inspector has not made any oral representations that are different from, or in addition to, what is written in this report, and (2) you agree to each provision of this report by relying on it any way, whether or not you sign it. f. You shall not allow anyone else to use or rely on this report without prior written consent. THIS REPORT CANNOT AND DOES NOT REPRESENT THE OPERATION OR CONDITION OF ANY ITEM AFTER THE DATE AND TIME OF THIS INSPECTION. ALL WARRANTIES, EXPRESSED OR IMPLIED ARE DISCLAIMED.

Signature: Inspection Date: 02/03/2018

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 4 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 6: Saraland, Alabama 36571 P.O. Box 414

General Information (Continued)

Property Information

Property Address City Chunchula State Alabama Zip 36521 Contact Name Phone

Client Information

Client Name Client Address Out of State Phone

Inspection Company

Inspector Name Jim Pinion Company Name Alabama Building Inspection Services LLC Address P.O. Box 414 City Saraland State Alabama Zip 36571 Phone 251-583-9933 State of Alabama License # HI-0694 E-Mail [email protected] File Number 02/03/18

Conditions

Others Present N/A Property Occupied Vacant Estimated Age Built 1986 Entrance Faces East Inspection Date 02/03/2018 Start Time 1:00 PM End Time 4:00 PM Electric On Yes No Not Applicable Gas/Oil On Yes No Not Applicable Water On Yes No Not Applicable Temperature 61 Weather Partly cloudy Soil Conditions Wet Space Below Grade None Building Type Single family Garage None Sewage Disposal Septic How Verified Multiple Listing Service Water Source City How Verified Visual Inspection

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 5 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 7: Saraland, Alabama 36571 P.O. Box 414

Lots and GroundsA NP NI M D

Driveway: Concrete Walks: Concrete Steps/Stoops: Concrete Porch: Concrete Enclosed Porch: Covered Deck: Treated wood Grading: Minor slope Vegetation: Shrubs, Trees,Grass Fences: Wood

ExteriorNote: Foundation On Clay Soil Requires Adequate And Even Around The Perimeter Of The Entire Year To Prevent Movement. Trees And Shrubs Can Cause Foundation Damage When Growing Too Close. Water Should Not Be Permitted To Pond Or Erode Under Or Along Side Any Part Of The Foundation. Depending On The Design And Method Or Original Construction Of A Pier And Beam Foundation, The Floor System May Need Leveling Periodically.

A NP NI M D

Front Elevation (Facing East) Exterior Surface Exterior Coverings: Triangle Shape Framing / Shingled - Dome shingled covering near end of useful life, where shingles meet at triangles this is of some concern (loose or lifted shingles. It appears that at the top of the dome shingles have deteriorated and a roof paint on sealer has been applied recommending roofing specialist evaluation.

Right Elevation Exterior Surface Exterior Coverings: Triangle Shape Framing / Shingled - Dome shingled covering near end of useful life, where shingles meet at triangles this is of some concern (loose or lifted shingles. It appears that at the top of the dome shingles have deteriorated and a roof paint on sealer has been applied recommending roofing specialist evaluation.

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 6 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 8: Saraland, Alabama 36571 P.O. Box 414

Exterior (Continued) Rear Elevation Exterior Surface

Exterior Coverings: Triangle Shape Framing / Shingled - Dome shingled covering near end of useful life, where shingles meet at triangles this is of some concern (loose or lifted shingles. It appears that at the top of the dome shingles have deteriorated and a roof paint on sealer has been applied recommending roofing specialist evaluation.

Left Elevation Exterior Surface Exterior Coverings: Triangle Shape Framing / Shingled - Dome shingled covering near end of useful life, where shingles meet at triangles this is of some concern (loose or lifted shingles. It appears that at the top of the dome shingles have deteriorated and a roof paint on sealer has been applied recommending roofing specialist evaluation.

Trim: Wood Entry Doors: Metal Patio Door: Metal sliding Windows: Aluminum Single Hung Window Screens: Mesh Exterior Lighting: Surface mount Exterior Electric Outlets: 120 VAC GFCI Hose Bibs: Gate Gas Meter: Exterior surface mount at side of home Main Gas Valve: Located at gas meter

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 7 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 9: Saraland, Alabama 36571 P.O. Box 414

RoofThe visible condition of the roof covering, flashing, skylights, chimneys and roof penetrations are inspected. The purpose of the inspection is to determine general condition.

A NP NI M D

All Slopes Roof Surface Method of Inspection: Drone the Dome It appears that at the top of the dome shingles have deteriorated and a roof paint on seal has been applied recommending roofing specialist evaluation

Unable to Inspect: Underlayment Material: Composite Roofing Shingles - Roof near end of useful life, where shingles meet at triangles this is of some concern (loose or lifted shingles. It appears that at the top of the dome shingles have deteriorated and a roof paint on seal has been applied recommending roofing specialist evaluation.

Type: Gable Approximate Age: Unknown

Flashing: Galvanized Valleys: Preformed metal Skylights: Glass

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 8 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 10: Saraland, Alabama 36571 P.O. Box 414

Roof (Continued)Plumbing Vents: PVC Electrical Mast: Mast with tie back at roof

West Slope Chimney Chimney: Metal surface mount direct vent

Flue/Flue Cap: Metal Chimney Flashing: Galvanized

GarageA NP NI M D

Front Elevation Garage Type of Structure: Detached Car Spaces: 2

Garage Doors: Metal - Garage door not closing down all the way. adjustments to garage door needed.

Door Operation: Mechanized Door Opener: Overhead Door Exterior Surface: Wood - Wood laminate separating & peeling off, evaluation by a license contractor is recommended.

Roof: Metal Roof Structure: 2x6 Rafter Service Doors: Metal Ceiling: Exposed framing Walls: Exposed framing Floor/Foundation: Monolithic poured slab

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 9 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 11: Saraland, Alabama 36571 P.O. Box 414

Garage (Continued)Laundry Tub: Fiberglass Laundry Tub Drain: PVC Hose Bibs: Gate Electrical: 120 VAC outlets and lighting circuits - Opening and exposed wiring should be in a sealed electrical junction box. Suggest evaluation by licensed electrician

Windows: Aluminum Single Hung Gutters: Plastic Downspouts: Plastic

ElectricalNote: Lights and Equipment Activated By Photo Cell Switches Were Not Checked. Also, Landscape and Exterior Grounds Lighting Is Not Included in This Inspection. Antiquated Wiring Should Be Updated. It Creates a Possible Fire and Shock Hazard.

A NP NI M D

Service Size Amps: 200 Volts: 120-240 VAC

Service: Underground 240 VAC Branch Circuits: Copper Aluminum Wiring: Service Feed/Panel Feed Conductor Type: Non-metallic sheathed cable Ground: Plumbing and rod in ground Smoke Detectors: Hard wired

Garage Electric Panel Manufacturer: General Electric

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 10 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 12: Saraland, Alabama 36571 P.O. Box 414

Electrical (Continued)Maximum Capacity: 100 Amps

Main Breaker Size: No single main breaker exists, Split bus design Breakers: Copper GFCI: Kitchen and bathrooms, outdoors

Is the panel bonded? Yes No Laundry Room Electric Panel

Manufacturer: General Electric

Maximum Capacity: 100 Amps Main Breaker Size: No single main breaker exists, Split bus design Breakers: Copper GFCI: Kitchen and bathrooms, outdoors

Is the panel bonded? Yes No

StructureExposed wood appears to have weathered and should be evaluated by license professional.

A NP NI M D

Structure Type: Wood frame Foundation: Post & Pier Beams: Wood - Exposed wood appears to have weathered and should be evaluated by license professional.

Bearing Walls: Triangle Shape Framing - Bearing wall has structural movement, causing cracking in interior and will require evaluationby a professonal. Piers/Posts: Wood piers and wood posts Floor/Slab: Composite wood or plywood Stairs/Handrails: Wood stairs with wood handrails - Exterior steps, stairs, decking and handrails, Exposed wood appears to have weathered and should be evaluated by license professional.

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 11 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 13: Saraland, Alabama 36571 P.O. Box 414

Structure (Continued)Stairs/Handrails: (continued)

Subfloor: Plywood

Crawl SpaceA NP NI M D

Rear Elevation Crawl Space Method of Inspection: In the crawl space

Unable to Inspect: Underlayment Access: Wood door Moisture Penetration: No moisture present at time of inspection

Moisture Location: None Ventilation: lattice Insulation: Fiberglass - Missing and loose insulation in areas

Electrical: secured HVAC Source: HVAC Service Lines

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 12 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 14: Saraland, Alabama 36571 P.O. Box 414

Air ConditioningNOTE: Air Conditions Units Are Not Checked When Outside Temperature Is Below 80 We Recommend the A.C. Unit Be Completely Serviced Before Each Cooling Season and The Condensate Drain Be Flushed with A Chlorine Bleach Every 2 Months During the Cooling Season to prevent Clogging. Could not verify the Tonnage and or Capacity's on HVAC systems.

A NP NI M D

Rear Elevation AC System A/C System Operation: Appears serviceable Condensate Removal: PVC Exterior Unit: Pad Mounted

Manufacturer: Unknown Model Number: No Legible Tag Serial Number: No Legible Tag

Area Served: Shared Approximate Age: Unknown Fuel Type: 240 VAC Temperature Differential: no reading Type: Central A/C Capacity: 3 Ton

Visible Coil: Copper core with aluminum fins Refrigerant Lines: Low pressure and high pressure Electrical Disconnect: Breaker disconnect Exposed Ductwork: Insulated flex Blower Fan/Filters: Direct drive with disposable filter Thermostats: Programmable

FireplaceRecommending having a chimney sweeper evaluation before using.

A NP NI M D

Family Room Fireplace Fireplace Construction: Prefab

Type: Wood burning Fireplace Insert: Standard Smoke Chamber: Metal, Brick - Explanation for this system is needed A qualified licensed contractor evaluation is recommended

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 13 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 15: Saraland, Alabama 36571 P.O. Box 414

Fireplace (Continued)Flue: Metal Damper: Metal Hearth: Raised

Heating SystemA NP NI M D

Closet Heating System Heating System Operation: Adequate

Manufacturer: Goodman Model Number: ARUF363616CA Serial Number: 1204087879 Type: Forced air Capacity: 36,000 BTUHR Area Served: Whole building Approximate Age: 2012 Fuel Type: Electric

Heat Exchanger: Heater kit strip Blower Fan/Filter: Direct drive with disposable filter Distribution: Metal duct Thermostats: Programmable

PlumbingPipes, Plumbing Equipment And Reservoirs Concealed Or Under The Ground Were not checked for leaks or defects-also- The serviceability or condition of the septic system or sewer system is not included in this inspection. Sprinkler systems were not part of this inspection. Pipes and plumbing in Walls, in or under concrete slabs or concealed by personal effects and their quality, condition or purification of water not included In this Inspection. the plumbing system is inspected visually and by operating a representative number of fixtures. Private water and waste systems are beyond the scope of a building inspection.

A NP NI M D

Service Line: Under Ground Main Water Shutoff: Front of house Water Lines: Copper Drain Pipes: PVC Service Caps: Accessible Vent Pipes: PVC

Laundry Room Water Heater Water Heater Operation: Functional at time of inspection

Manufacturer: Whirlpool Model Number: E2F80HD045V Serial Number: 2033T429149 Type: Natural gas Capacity: 80 Gal. Approximate Age: 2008 Area Served: Whole building

TPRV and Drain Tube: Copper

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 14 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 16: Saraland, Alabama 36571 P.O. Box 414

BathroomA NP NI M D

2nd floor Bathroom Ceiling: Drywall & Paint Walls: Drywall & Paint Floor: Ceramic tile Doors: Hollow wood Electrical: 120 VAC outlets and lighting circuits Counter/Cabinet: Laminate and wood Sink/Basin: Molded single bowl Faucets/Traps: Fixtures with a PVC trap Tub/Surround: Fiberglass tub and ceramic tile surround Shower/Surround: Fiberglass pan and fiberglass surround Toilets: 3 Gallon Tank HVAC Source: Heating system register Ventilation: Electric ventilation fan

1st Floor Bathroom Ceiling: Drywall & Paint Walls: Drywall & Paint Floor: Ceramic tile Doors: Hollow wood Windows: aluminum slider Electrical: 120 VAC outlets and lighting circuits Counter/Cabinet: Laminate and wood Sink/Basin: Molded single bowl Faucets/Traps: Fixtures with a PVC trap Tub/Surround: Fiberglass tub and fiberglass surround Shower/Surround: Fiberglass tub and fiberglass surround Toilets: 3 Gallon Tank HVAC Source: Heating system register Ventilation: Electric ventilation fan

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 15 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 17: Saraland, Alabama 36571 P.O. Box 414

Kitchen W/Eat-in Breakfast NookThis is a cursory check only of the specified appliances. The accuracy or operation of timers, temperature or power levels controls is beyond the scope of this inspection.

A NP NI M D

Rear Elevation Kitchen Cooking Appliances: General Electric Ventilator: Nautilus Dishwasher: Whirlpool

Air Gap Present? Yes No Refrigerator: Estate Sink: Stainless Steel Electrical: 120 VAC outlets and lighting circuits Plumbing/Fixtures: Chrome, PVC - The faucet is leaking.

Counter Tops: Formica Cabinets: Wood Ceiling: Drywall & Paint - ceilings and walls appear to have cracking recommending contractor to evaluate Walls: Drywall & Paint - ceilings and walls appear to have cracking recommending contractor to evaluate Floor: Hardwood Doors: Metal Windows: Aluminum Single Hung HVAC Source: Heating system register

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 16 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 18: Saraland, Alabama 36571 P.O. Box 414

BedroomA NP NI M D

1st Floor Master Bedroom Closet: Single, Walk In Ceiling: Drywall & Paint Walls: Drywall & Paint Floor: Hardwood Doors: Hollow wood Windows: Aluminum Single Hung Electrical: 120 VAC outlets and lighting circuits HVAC Source: Heating system register

Bedroom 1 Upstairs Bedroom Closet: Walk In Ceiling: Drywall & Paint - stress cracking noted in the walls

Walls: Drywall & Paint - stress cracking noted on the walls by the exterior windows Floor: Carpet Doors: Hollow wood Windows: Aluminum Single Hung Electrical: 120 VAC outlets and lighting circuits HVAC Source: Heating system register

Bedroom 2 Upstairs Bedroom Closet: Single Ceiling: Drywall & Paint Walls: Drywall & Paint Floor: Carpet Doors: Hollow wood Windows: Aluminum Single Hung Electrical: 120 VAC outlets and lighting circuits HVAC Source: Heating system register

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 17 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 19: Saraland, Alabama 36571 P.O. Box 414

Living SpaceThe interior inspection is limited to readily accessible areas that are not concealed by furnishings or stored items and representative number of windows and doors.

A NP NI M D

Living Room Living Space Ceiling: Drywall & Paint - Stress cracking noted in windows, ceiling and walls, Evidence of pass moisture and present water staining, Loose or peeling paint, Evaluation by a license professional contractor is recommended.

Walls: Drywall & Paint - Stress cracking noted in windows, ceiling and walls, Evidence of pass moisture and present water staining, Loose or peeling paint, Evaluation by a license professional contractor is recommended.

Floor: Hardwood Doors: Hollow wood Windows: Aluminum Single Hung Electrical: 120 VAC outlets and lighting circuits HVAC Source: Heating system register Smoke Detector: Located upstairs - Inoperative at time of inspection

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 18 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 20: Saraland, Alabama 36571 P.O. Box 414

Laundry Room/AreaA NP NI M D

Next To Kitchen Laundry Room/Area Closet: Single Ceiling: Drywall & Paint Walls: Drywall & Paint Floor: Split Brick Doors: None Windows: Aluminum Single Hung Electrical: 120- 240 VAC outlets and lighting circuits HVAC Source: Heating system register

ON - Off handle broken Washer Hose Bib: Ball valves - A evaluate by a licensed plumber is

recommended.

Washer and Dryer Electrical: 120-240 VAC Dryer Vent: Metal flex Washer Drain: Wall mounted drain

Final CommentsThe 2V Geodesic Dome Home is located at 14215 Highway 45 Chunchula, AL 36521. The building was constructed in the 1980's, and is in good overall condition. The building is a single-family, with a dome shingled roof & wall covered finished. some concerns warrant attention please read complete report.

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 19 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 21: Saraland, Alabama 36571 P.O. Box 414

Marginal SummaryThis summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report.

Roof

1. All Slopes Roof Surface Material: Composite Roofing Shingles - Roof near end of useful life, where shingles meet at triangles this is of some concern (loose or lifted shingles. It appears that at the top of the dome shingles have deteriorated and a roof paint on seal has been applied recommending roofing specialist evaluation.

Garage

2. Front Elevation Garage Garage Doors: Metal - Garage door not closing down all the way. adjustments to garage door needed.

3. Front Elevation Garage Exterior Surface: Wood - Wood laminate separating & peeling off, evaluation by a license contractor is recommended.

4. Front Elevation Garage Electrical: 120 VAC outlets and lighting circuits - Opening and exposed wiring should be in a sealed electrical junction box. Suggest evaluation by licensed electrician

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 20 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 22: Saraland, Alabama 36571 P.O. Box 414

Marginal Summary (Continued)Structure

5. Beams: Wood - Exposed wood appears to have weathered and should be evaluated by license professional.

6. Bearing Walls: Triangle Shape Framing - Bearing wall has structural movement, causing cracking in interior and will require evaluationby a professonal.

7. Stairs/Handrails: Wood stairs with wood handrails - Exterior steps, stairs, decking and handrails, Exposed wood appears to have weathered and should be evaluated by license professional.

Crawl Space

8. Rear Elevation Crawl Space Insulation: Fiberglass - Missing and loose insulation in areas

Kitchen W/Eat-in Breakfast Nook

9. Rear Elevation Kitchen Ceiling: Drywall & Paint - ceilings and walls appear to have cracking recommending contractor to evaluate

10. Rear Elevation Kitchen Walls: Drywall & Paint - ceilings and walls appear to have cracking recommending contractor to evaluate

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 21 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 23: Saraland, Alabama 36571 P.O. Box 414

Marginal Summary (Continued) Marginal Summary (Continued)Bedroom

11. Bedroom 1 Upstairs Bedroom Walls: Drywall & Paint - stress cracking noted on the walls by the exterior windows

Living Space

12. Living Room Living Space Ceiling: Drywall & Paint - Stress cracking noted in windows, ceiling and walls, Evidence of pass moisture and present water staining, Loose or peeling paint, Evaluation by a license professional contractor is recommended.

13. Living Room Living Space Walls: Drywall & Paint - Stress cracking noted in windows, ceiling and walls, Evidence of pass moisture and present water staining, Loose or peeling paint, Evaluation by a license professional contractor is recommended.

Laundry Room/Area ON - Off handle broken 14. Next To Kitchen Laundry Room/Area Washer Hose Bib: Ball valves - A evaluate by a

licensed plumber is recommended.

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 22 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.

Page 24: Saraland, Alabama 36571 P.O. Box 414

Defective SummaryThis summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report.

Living Space

1. Living Room Living Space Smoke Detector: Located upstairs - Inoperative at time of inspection

Alabama Building Inspection Services LLC12:28 December 18, 2018 Page 23 of 23

Palm-Tech Inspector, Copyright © 1998-2018, PDmB, Inc.