SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 3 –
Dear Customer,
Since 1921, Scanlan International has been dedicated to working closely with surgeons to provide the highest quality, innovative surgical instruments.
The specialties of thoracic and cardiac surgery are continuing to evolve from a conventional open approach to a thoracoscopic / minimally invasive approach. This evolution to video-assisted thoracic surgery (VATS) and minimally invasive cardiac (MIS) surgery have been the catalyst for a new generation of specialty surgical instrumentation.
Scanlan pioneered and continues to be the leader with innovative VATS and MIS specialty instrumentation. Scanlan® minimally invasive instruments offer a unique dual pivot point design that enables the instrument to be fully functional when placed through a port or very small thoracic incision while still providing the familiarity of traditional style handles for a comfortable feel and superior tactile response.
If I can ever be of assistance to you, please contact me toll-free within the United States and Canada or collect from anywhere in the world. Thank you for your continued support and demand for the finest surgical instrumentation.
Sincerely,
Timothy M. ScanlanPresident and Chief Executive Officer
VATS MISSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive Instruments
TimScanlan
BrigidScanlan Eiynck
Adam Scanlan
RussellScanlan
Chenoa Scanlan
Ron Peick
JosephScanlan
D’Amico Biopsy Forceps . . . . . . . . . . . . . . . . . . . . . 6
Rocco Nodule Clamps . . . . . . . . . . . . . . . . . . . . . 10
Clamps / Graspers / Dissectors . . . . . . . . . . . . . . 12 Gonzalez-Rivas Lung Grasping Clamp . . . . . . . . . . . 12 Foerster Lung Grasping Clamp . . . . . . . . . . . . . . . . 12 Duval Lung Grasping Clamp . . . . . . . . . . . . . . . . . 18 Node Grasping Clamp . . . . . . . . . . . . . . . . . . . . . 18 Khan Decortication Grasper . . . . . . . . . . . . . . . . . . 20 Gonzalez-Rivas Dissector . . . . . . . . . . . . . . . . . . . . 22 DeBakey Cooley Forceps (Clamp) . . . . . . . . . . . . . 22 Harken Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Dennis Dissector . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Allis Forceps (Clamp) . . . . . . . . . . . . . . . . . . . . . . . 26 D’Amico DeBakey Clamp . . . . . . . . . . . . . . . . . . . . 28 Chitwood DeBakey Clamp . . . . . . . . . . . . . . . . . . . 28
Scissors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Super Cut™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Forceps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Axial Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Spring Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Needle Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Spring Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Ring Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Axial Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Knot Pushers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Suture Cutters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Suction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Wolf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Dennis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 D’Amico . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Dennis Rib Cutter . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Sterns™ Chest Tube Passer . . . . . . . . . . . . . . . . . . . 64
Suture Pullers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Instrument Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 4 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 5 –
Key Features of SCANLAN® VATS / MIS Instrumentsn Unique dual pivot point, sliding-shaft design enables the instrument to be
fully functional when placed through a port or very small incision.
SCANLAN® Unique Dual Pivot Point, Sliding-shaft Design
Single Pivot PointConventional surgical instruments have a single pivot point (as indicated for the 7007-242SC scissors below). When inserted through a port or very small thoracic incision, the function of a single pivot point instrument significantly reduces the opening of the shanks, which affects the distance the blades / jaws can be opened.
Conventional Ring Style Handles
n Provides a familiar, comfortable feel in the surgeon’s hand.
n Allows the surgeon to focus on the surgical technique rather than on how to use the instrument.
Axial Handles
n Innovative handle design that provides superior balance and feel.
n Perfect for surgeons who prefer thoracoscopic instruments that allow them to “roll the handles between their fingertips.”
n The ergonomic handle design provides a secure grasp that is comfortable and familiar.
n Individually hand crafted – Scanlan’s skilled artisans create one unique instrument at a time… to ensure tactile feel, balance and performance.
n Durability – Scanlan uses only the highest quality stainless steel to produce long-lasting, corrosion resistant surgical instrumentation.
n Guarantee – Ten full years against manufacturing and material defects.
Conventional Scissors 7007-242SC
Dual Pivot PointScanlan VATS / MIS instruments have 2 pivot points (port compatible) with a sliding shaft between them as indicated for the 9909-910SC scissors below. The advantage of this design is that when the instrument is inserted through a port or very small thoracic incision, the instrument is fully functional. The length of the instrument from the blade / jaw tips to slightly before pivot point 2 is the working length which can be inserted through a port or very small incision without affecting functionality.
Pivot Point 1
Pivot Point 1
Working Length
Total Length
Sliding Shaft
Shaft
Pivot Point 2
VATS / MIS Scissors 9909-910SCVATS
VATS VATS
MIS
MIS MISSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive InstrumentsSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive Instruments
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 6 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 7 –
SCANLAN®
D’Amico Biopsy ForcepsDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN®
D’Amico Biopsy ForcepsDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN®
D’Amico Biopsy ForcepsDeveloped in cooperation with Thomas A. D’Amico, MD
VATS
VATS Procedures
n This versatile instrument can be used as both a dissector and as a biopsy forceps.
n Dissector - the opening and curve of the oval ring jaws provide visualization of the target tissue making this a very useful instrument for dissection.
n Biopsy - The 6 mm width serrated oval jaws provide a secure grasp of the node tissue for ample tissue yield with each bite.
n Unique 5 mm to 7 mm tapered shaft design. The finer 5 mm shaft is optimized for improved visibility and ergonomics. The 7 mm pivot points provide strength and durability.
n Conventional style handles provide a familiar, comfortable feel.
n Available with or without ratchets.
VATS Procedures
n The 7 mm width oval cupped jaws provide a secure grasp of the node tissue for maximum tissue yield with each bite.
n The curved jaws improve visualization of the biopsy site.
n Unique 5 mm to 7 mm tapered shaft design. The finer 5 mm shaft is optimized for improved visibility and ergonomics. The 7 mm pivot points provide strength and durability.
n Conventional style handles provide a familiar, comfortable feel.
n Available with or without ratchets.
Cat . No . Description Shaft
Working Length
Total Length
9009-3026 mm width oval ring jaws Curved With ratchet 5 mm
Tapered to 7 mm
9”(23 cm)
13”(33 cm)
9009-3036 mm width oval ring jaws Curved Without ratchet
Cat . No . Description Shaft
Working Length
Total Length
9009-3127 mm width oval cupped jaws Curved With ratchet 5 mm
Tapered to 7 mm
9”(23 cm)
13”(33 cm)
9009-3137 mm width oval cupped jaws Curved Without ratchet
9009-3029009-303
9009-3129009-313
9009-3009009-301
9009-3109009-311
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 8 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 9 –
VATS
VATS Procedures
n This versatile instrument can be used as both a dissector and as a biopsy forceps.
n Dissector - the opening and curve of the oval ring jaws provide visualization of the target tissue making this a very useful instrument for dissection.
n Biopsy - The 6 mm width serrated oval jaws provide a secure grasp of the node tissue for ample tissue yield with each bite.
n Durable, robust design.
n Conventional style handles provide a familiar, comfortable feel.
n Available with or without ratchets.
VATS Procedures
n The 7 mm width oval cupped jaws provide a secure grasp of the node tissue for maximum tissue yield with each bite.
n The curved jaws improve visualization of the biopsy site.
n Durable, robust design.
n Conventional style handles provide a familiar, comfortable feel.
n Available with or without ratchets.
Cat . No . Description Shaft
Working Length
Total Length
9009-3006 mm width oval ring jaws Curved With ratchet
7 mm 11”(28 cm)
15”(38 cm)
9009-3016 mm width oval ring jaws Curved Without ratchet
Cat . No . Description Shaft
Working Length
Total Length
9009-3107 mm width oval cupped jaws Curved With ratchet
7 mm 11”(28 cm)
15”(38 cm)
9009-3117 mm width oval cupped jaws Curved Without ratchet
SCANLAN®
D’Amico Mediastinoscopy ForcepsDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN®
D’Amico Mediastinoscopy ForcepsDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN®
D’Amico Mediastinoscopy ForcepsDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 10 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 11 –
VATSSCANLAN®
NEW Rocco Nodule ClampsDeveloped in cooperation with Gaetano Rocco, MD, FRCSEd, FEBTS, FCCP
Cat . No . Description
Suggested Nodule Size* Shaft
Working Length
Total Length
NEW 9909-946
Curved left ring jaws 3.0 cm inner diameter and 3.7 cm outer diameter with ratchet
Up to 1 cm
10 mm 9 1/2” (24 cm)
13 1/4” (33.5 cm)
NEW 9909-947
Curved left ring jaws 4.5 cm inner diameter and 5.2 cm outer diameter with ratchet
Between 1 and 1.5 cm
SCANLAN®
Rocco Nodule ClampsDeveloped in cooperation with Gaetano Rocco, MD, FRCSEd, FEBTS, FCCP
VATS and Open Thoracotomy Procedures
n Developed to assist the surgeon in the excision of small peripheral (outer third of the lung) nodules
n Can be used during a VATS wedge resection or an open thoracotomy wedge resection.
n Choice of 2-ring sizes:
n 3.0 cm Inner Diameter, 3.7 cm Outer Diameter
n 4.5 cm Inner Diameter, 5.2 cm Outer Diameter
n Used to briefly and atraumatically grasp the lung parenchyma containing a nodule to be excised. When the clamp is removed, a temporary, circumferential line of demarcation may be visualized where the rings of the jaws had been clamped.
n 9-ratchet closure design – this design ensures the jaws are parallel and the rings 1 cm apart when the handle is closed to the 5th ratchet. Actuating ratchets 6-9 further closes the jaws.
n 1 cm spacing offset between proximal end of the jaws (non-ring) when the jaws are closed to the 5th ratchet minimizes trauma to the lung tissue in the proximal end of the jaws. This allows use of the clamp on more central (thicker) tissue.
9909-946
9909-947
3.0 cm 4.5 cm
*Suggested Nodule Size per Gaetano Rocco, MD, FRCSEd, FEBTS, FCCP
9009-230
9009-229
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 12 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 13 –
VATS
VATS
SCANLAN®
NEW Gonzalez-Rivas Lung Grasping ClampDeveloped in cooperation with Diego Gonzalez-Rivas, MD, FECTS
SCANLAN®
NEW Foerster Lung Grasping Clamp
VATS Procedures
n High tension design provides very secure grasp when retracting lung tissue anteriorly during Uniportal VATS procedures.
n 20 mm oval ring jaws provide an atraumatic, secure grasp that won’t tear or damage lung tissue.
n Unique 7 mm to 10 mm tapered shaft design. The finer 7 mm shaft provides improved visibility and ergonomics. The 10 mm pivot points provide strength and durability.
n May be used for grasping a well-folded sponge as a “sponge-stick” for both blunt dissection and to apply pressure for temporary control of bleeding.
VATS Procedures
n Unique 5 to 7 mm tapered shaft design. The finer 5 mm shaft is optimized for atraumatic insertion between the ribs and improved visibility and ergonomics. The 7 mm pivot points provide strength and durability.
n 20 mm oval ring jaws provide an atraumatic, secure grasp.
n Not recommended for use as a “sponge-stick.”
Cat . No . Description Shaft
Working Length
Total Length
NEW 9009-230
High tension Curved left 20 mm oval ring jaws With ratchet
7 mm Tapered
to10 mm
5 3/4” (14.5 cm)
9 3/4” (24.5 cm)
Cat . No . Description Shaft
Working Length
Total Length
NEW 9009-229
Curved left 20 mm oval ring jaws with ratchet
5 mm Tapered
to7 mm
9 1/4” (23.5 cm)
13 1/4”(33.5 cm)
SCANLAN®
Gonzalez-Rivas Lung Grasping ClampDeveloped in cooperation with Diego Gonzalez-Rivas, MD, FECTS
SCANLAN®
Foerster Lung Grasping Clamp
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 14 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 15 –
VATSSCANLAN®
Foerster Lung Grasping Clamps
VATS Procedures
n The 12 mm oval ring jaws provide an atraumatic, secure grasp that won’t tear or damage lung tissue.
n This instrument may also be used to grasp lymph nodes.
n This shorter length works well for smaller size patients, grasping lung tissue close to working ports/incisions.
n Choice of standard left curve jaw or right curve jaw (left-hand style).
n Not recommended for use as a “sponge-stick.”
VATS Procedures
n The 12 mm oval ring jaws provide an atraumatic, secure grasp that won’t tear or damage lung tissue.
n This instrument may also be used to grasp lymph nodes.
n This classic length works well for a variety of patient sizes for most multiple-port/incision or Uniportal VATS procedures.
n Not recommended for use as a “sponge-stick.”
Cat . No . Description Shaft
Working Length
Total Length
9009-227Curved right jaws (left-hand style) 12 mm oval ring jaws With ratchet
7 mm 7 1/2” (19 cm)
11 1/2” (29 cm)
9009-228Curved left jaws 12 mm oval ring jaws With ratchet
Cat . No . Description Shaft
Working Length
Total Length
9009-226Curved left jaws12 mm oval ring jaws With ratchet
7 mm 9 1/4” (23.5 cm)
13 1/4” (33.5 cm)
9009-227
9009-228
9009-226
SCANLAN®
Foerster Lung Grasping Clamps
SCANLAN®
Foerster Lung Grasping Clamps
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 16 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 17 –
VATSSCANLAN®
Foerster Lung Grasping Clamps
VATS Procedures
n The 20 mm oval ring jaws provide an atraumatic, secure grasp that won’t tear or damage lung tissue.
n This shorter length works well for smaller size patients or when grasping lung tissue close to working ports/incisions.
n May be used for grasping a well-folded sponge to use as a “sponge-stick for both blunt dissection and to apply pressure for temporary control of bleeding.
n Choice of standard left curve jaw or right curve jaw (left-hand style).
VATS Procedures
n The oval ring jaws provide an atraumatic, secure grasp that won’t tear or damage lung tissue.
n This classic length works well for a variety of patient sizes and for most multi-port or Uniportal VATS procedures.
n May be used for grasping a well-folded sponge to use as a “sponge-stick for both blunt dissection and to apply pressure for temporary control of bleeding.
n NEW 25 x 35 mm oval ring jaws provide an atraumatic, secure grasp on delicate, friable tissue such as emphysematous lung tissue.
Cat . No . Description Shaft
Working Length
Total Length
9909-921Curved right jaws (left-hand style) 20 mm oval ring jaws With ratchet
10 mm 7 1/2” (19 cm)
11 1/2” (29 cm)
9909-922Curved left jaws20 mm oval ring jaws With ratchet
Cat . No . Description Shaft
Working Length
Total Length
9909-920Curved left jaws20 mm oval ring jaws With ratchet
10 mm 9 1/2” (24 cm)
13 1/4” (33.5 cm)
9909-923Deep curved left jaws 20 mm oval ring jaws With ratchet
13” (33 cm)
NEW 9909-924
Curved left jaws 25 x 35 mm oval ring jaws With ratchet
13 1/4” (33.5 cm)
9909-921
9909-920
9909-922
9909-923
9909-924
SCANLAN®
Foerster Lung Grasping Clamps
SCANLAN®
Foerster Lung Grasping Clamps
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 18 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 19 –
VATS
VATS
SCANLAN®
Duval Lung Grasping Clamps
SCANLAN®
Node Grasping Clamps
9909-926
9009-222
9909-927
9009-2239009-225
VATS Procedures
n The Duval triangular ring jaws provide an atraumatic, secure grasp.
n The triangular shaped jaws of the Duval clamp may be used during dissection of lymph nodes to securely grasp the nodes.
Cat . No . Description Shaft
Working Length
Total Length
9909-926Curved left jaws1.0 cm width triangular ring jaws With ratchet
10 mm 9 1/4” (23.5 cm)
13 1/2” (34 cm)
9909-927Curved left jaws2.5 cm width triangular ring jaws With ratchet
Cat . No . Description Shaft
Working Length
Total Length
9009-222Straight jaws11 cm oblong ring jaws With ratchet
5 mm 9” (23 cm)
13” (33 cm)9009-223
Curved jaws11 cm oblong ring jaws With ratchet
9009-225Curved jaws11 cm oblong ring jaws Without ratchet
SCANLAN®
Duval Lung Grasping Clamps
SCANLAN®
Node Grasping Clamps
VATS Procedures
n The small oval ring jaws provide a secure grasp of lymph nodes during lymph node dissection.
n May be used as a dissector during VATS procedures.
n The curved jaw improves visualization during VATS procedures.
n Available with or without ratchets.
n Not recommended for use as a lung grasper.
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 20 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 21 –
VATSSCANLAN®
NEW Khan Decortication GrasperDeveloped in cooperation with Prof. Ali Zamir Khan, MS, FRCS(Glasg), FRCS(CTh), FEBTS, MBA
VATS Procedures
n Perfect for use during VATS decortication procedures.
n Can also be used for open thoracotomy decortication procedures.
n Robust grasper which securely grasps the thick, fibrous peel during decortication procedures.
n 20 mm oval ring jaws.
n Enhanced jaw serrations provide a secure grasp of thick, fibrous tissue.
n Reinforced jaws to withstand increased torque.
n One gold finger ring provides immediate differentiation between the Khan Decortication Grasper and a Foerster Lung Clamp.
n Not recommended for use as a lung grasper.
Cat . No . Description Shaft
Working Length
Total Length
NEW9909-940
Enhanced serrations Curved left jaws With ratchet
10 mm 9 1/2” (24 cm)
13 1/4” (33.5 cm)
SCANLAN®
Khan Decortication GrasperDeveloped in cooperation with Prof. Ali Zamir Khan, MS, FRCS(Glasg), FRCS(CTh), FEBTS, MBA
Kahn Decortication Grasper JawsCompared to
Foerster Clamp Jaws
9909-940Khan Decortification Grasper
9909-920Foerster Lung Clamp
9909-940
9009-210 and 9009-211Regular jaw tips (approximate size)
9009-212 and 9009 213 Fine jaw tips
(approximate size)
SCANLAN® Gonzalez-Rivas DissectorRegular Jaw Tips Compared to Fine Jaw Tips
SCANLAN®
Gonzalez-Rivas DissectorDeveloped in cooperation with Diego Gonzalez-Rivas, MD, FECTS
Cat . No . Description Shaft
Working Length
Total Length
9009-210Mixter-style 1 x 2 DeBakey jaws With ratchet
5 mm 7 1/2” (19 cm)
11 1/2” (29 cm)
9009-211Mixter-style 1 x 2 DeBakey jaws Without ratchet
NEW 9009-212
Mixter-style 1 x 2 DeBakey jawsFine tips With ratchet
NEW 9009-213
Mixter-style 1 x 2 DeBakey jawsFine tips Without ratchet
VATS Procedures
n Low profile 5 mm shaft design.
n Mixter-style jaw facilitates dissection of key structures.
n Atraumatic 1x2 DeBakey jaws.
nFine tip selection now available.
n Choice of with or without ratchet.
9009-2109009-211
9009-2129009-213
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 22 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 23 –
VATSSCANLAN®
Gonzalez-Rivas DissectorDeveloped in cooperation with Diego Gonzalez-Rivas, MD, FETCS
SCANLAN®
DeBakey Cooley ForcepsVATS MIS
VATS ProceduresMIS Procedures
nn Often referred to as a “Right Angle.”
n The fine yet blunt 90º angled jaws make this one of the key instruments used for blunt dissection to mobilize and encircle the artery, vein and bronchus.
nn Available with or without a ratchet.
SCANLAN®
DeBakey Cooley Clamps Cat . No . Description Shaft
Working Length
Total Length
9909-202 DeBakey Cooley JawsWith ratchet
10 mm 9 1/2” (24 cm)
13 1/2” (34 cm)
9909-203 DeBakey Cooley JawsWithout ratchet
9909-2029909-203
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 24 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 25 –
VATS Procedures
n Sometimes referred to as a “Pedicle” or “Semb” clamp.
n The blunt ends and curved shapes of these jaws make them very useful instruments for blunt dissection to mobilize and encircle the artery, vein and bronchus for a wide range of patient anatomy.
n The tapered jaws of these clamps facilitate dissection.
n NEW Shorter length with 5 mm to 7 mm tapered shaft.
n Available with or without ratchet.
VATSSCANLAN®
Harken Clamps
Cat . No . Description Shaft
Working Length
Total Length
NEW 9009-250
Harken #17.5 cm jaws Tapered 1x2 DeBakey jawsWithout ratchet
5 mm to7 mm
tapered
7 1/2”(19 cm)
11 1/2”(29 cm)
NEW 9009-251
Harken #17.5 cm jaws Tapered 1x2 DeBakey jawsWith ratchet
NEW 9009-252
Harken #2 7.5 cm jaws Tapered 1x2 DeBakey jawsWithout ratchet
NEW 9009-253
Harken #2 7.5 cm jaws Tapered 1x2 DeBakey jawsWith ratchet
9909-224
Harken #19.5 cm jaws Tapered 1x2 DeBakey jawsWithout ratchet
10 mm 9 7/8” (24.8 cm)
14” (35.5 cm)
9909-225
Harken #1 9.5 cm jaws Tapered 1x2 DeBakey jawsWith ratchet
9909-226
Harken #2 9.5 cm jaws Tapered 1x2 DeBakey jawsWithout ratchet
9909-227
Harken #2 9.5 cm jaws Tapered 1x2 DeBakey jawsWith ratchet
9009-2509009-251
9909-2249909-225
9009-2529009-253
9909-2269909-227
9009-250
9909-224
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 26 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 27 –
VATSSCANLAN®
Allis Forceps (Clamp)MIS
Cat . No . Description Shaft
Working Length
Total Length
9009-270Curved left jaws6 mm width jaws With ratchet
7 mm 9” (23 cm)
13 1/4” (33.5 cm)
SCANLAN®
Allis Forceps
VATS ProceduresMIS Procedures
Allis forceps are very useful for both VATS and MIS procedures to grasp and manipulate tissue such as:
n Lymph nodes
n Bronchus
nn Pericardium
nn Stiff or fibrous tissue
9009-270
9009-2809009-281
SCANLAN®
Dennis DissectorVATS MIS
Cat . No . Description Shaft
Working Length
Total Length
9009-280Curved left jawsSerrated jaws With ratchet
7 mm 9” (23 cm)
13 1/4” (33.5 cm)
9009-281Curved left jawsSerrated jaws Without ratchet
SCANLAN®
Dennis Dissector
VATS ProceduresMIS Procedures
This versatile instrument has serrated jaws and may be used for both VATS and MIS procedures as a:
nn Dissector
nn Hemostat
nn Instrument that passes silk ties or a vessel loop into the operative field for encircling the artery, vein or bronchus.
nn Available with or without ratchets.
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 28 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 29 –
VATSSCANLAN®
D’Amico DeBakey ClampsDeveloped in cooperation with Thomas A. D’Amico, MD
VATS Procedures
n The tapered jaws of these clamps were developed specifically to facilitate and ease dissection of key structures during VATS procedures.
n The curved jaws are perfect for blunt dissection to mobilize the artery, vein and bronchus.
n The straight jaws may be used as a guide prior to stapling by passing behind the mobilized artery, vein or bronchus to replicate the direction of the linear stapler.
n The straight jaws may be used to clamp the lung tissue parallel to the stapler when stapling the lung tissue; this creates even tissue tension which results in a smooth, even staple line.
n Available with or without ratchets.
Cat . No . Description Shaft
Working Length
Total Length
9909-219
Curved left jawsTapered 1x2 DeBakey jaws 11cm jaw lengthWithout ratchet
10 mm
10” (25.4 cm)
14 1/2” (37 cm)
9909-221
Curved left jawsTapered 1x2 DeBakey jaws 11cm jaw length With ratchet
9909-222
Straight jawsTapered 1x2 DeBakey jaws 11.5 cm jaw length With ratchet
10 1/2” (27 cm)
14 3/4” (37.5 cm)
SCANLAN®
D’Amico DeBakey ClampsDeveloped in cooperation with Thomas A. D’Amico, MD9909-222
9909-221 9909-219
D’Amico Tapered Jaw Tip Compared to
Chitwood DeBakey Jaw Tip
9909-221D’Amico curved tapered 1 x 2 DeBakey jaws
9909-912-13Chitwood curved 1 x 2 DeBakey jaws
9009-2409009-241
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
Cat . No . Description Shaft
Working Length
Total Length
9009-240
6 cm jaw lengthCurved left jaws1 x 2 DeBakey jawsWith ratchet
5 mm 8 1/4” (21 cm)
12 1/4” (31 cm)
9009-241
6 cm jaw lengthCurved left jaws1 x 2 DeBakey jawsWithout ratchet
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
VATS MIS
VATS ProceduresMIS Procedures
n This clamp may be used as an aortic cross-clamp for minimally invasive cardiac procedures for pediatric and small patients.
n The 1 x 2 DeBakey jaws provide an atraumatic and secure grasp of the aorta.
n VATS: The rounded blunt ends of the jaws are perfect for blunt dissection to mobilize the artery, vein and bronchus.
nn Available with or without ratchets.
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 30 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 31 –
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
VATS MIS
Cat . No . Description Shaft
Working Length
Total Length
9909-912
6.5 cm jaw length1x2 DeBakey jawsCurved left jaws With ratchet
10 mm
9” (23 cm)
12 3/4” (32.5 cm)
9909-912-13
10 cm jaw length1x2 DeBakey jaws Curved left jaws With ratchet 10”
(25.4 cm)14 1/4” (36 cm)
9909-232
10 cm jaw length2x3 DeBakey jaws Curved left jaws With ratchet
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
9909-232
VATS Procedures
n The rounded blunt ends of the jaws are perfect for blunt dissection to mobilize the artery, vein and bronchus.
n May be used as a guide prior to stapling by passing behind the mobilized artery, vein or bronchus to replicate the direction of the linear stapler.
n May be used to clamp the lung tissue parallel to the stapler when stapling the lung tissue; this creates even tissue tension which results in a smooth, even staple line.
MIS Procedures
n Used as an aortic cross-clamp for minimally invasive cardiac procedures such as valve replacement or repair.
n This clamp may be positioned on the aorta via a sub-axillary incision.
n The selection of jaw sizes accommodates a wide range of patient sizes and anatomy.
n The 1 x 2 DeBakey jaws provide an atraumatic and secure grasp of the aorta. The wider 2x3 DeBakey jaws of the 9909-232 clamp provide an even more gentle yet secure grasp of the aorta.
9909-912
9909-912-13
9909-912-131 x 2 DeBakey jaws
9909-2322 x 3 DeBakey jaws
DeBakey Jaw Styles
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 32 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 33 –
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
MIS
MIS Procedures
nLength optimized for smaller frame patients.
nUsed for minimally invasive cardiac procedures such as valve replacement or repair.
nChoice of left or right curved jaws.
n Left curve jaw – recommended when the clamp is positioned on the aorta via a right sub-axillary incision so that the tips of the jaws point to the patient’s left shoulder.
n Right curve jaw – recommended when the clamp is positioned on the aorta via a left sub-axillary incision so that the tips of the jaws point to the patient’s right shoulder.
nAtraumatic 1 x 2 DeBakey jaws.
Cat . No . Description Shaft
Working Length
Total Length
9909-914
7 cm jaw lengthCurved left jaw1x2 DeBakey jaws With ratchet
10 mm 6 3/4” (17 cm)
10 3/8” (26.4 cm)
9909-915
7 cm jaw lengthCurved right jaw1x2 DeBakey jaws With ratchet
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
9909-915
9909-914VATS Procedures
n Length optimized for smaller frame patients.
n The round blunt ends of the jaws are perfect for blunt dissection to mobilize the vein, artery and brochus.
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 34 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 35 –
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
MIS
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
SCANLAN®
Chitwood DeBakey ClampsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
MIS Procedures
n May be positioned on the aorta directly through a partial / hemi-sternotomy or a mini – thoracotomy incision.
n Angled shanks – keeps the handle out of the surgeon’s view and out of the surgeon’s working area.
n Atraumatic 2 x 3 DeBakey jaws.
MIS Procedures
n Shorter length optimized for smaller frame patients.
n The clamp may be positioned on the aorta via a right sub-axillary incision.
n Angled shanks – cause the handle to “hug” the patient’s right side after the clamp is positioned which keeps the handle out of the surgeon’s way.
n Atraumatic 1 x 2 DeBakey jaws.
Cat . No . Description Shaft
Working Length
Total Length
NEW 9909-234
8 cm jaw lengthCurved left jaws2 x 3 DeBakey jawsAngled shanks
10 mm 5 1/8” (13 cm)
8” (20.5 cm)
Cat . No . Description Shaft
Working Length
Total Length
9909-913
7 cm jaw lengthCurved left jaws1 x 2 DeBakey jawsAngled shanks
10 mm 6 3/4” (17 cm)
9 3/4” (24.8 cm)
9909-234
9909-913
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 36 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 37 –
SCANLAN®
Super Cut™ ScissorsVATS MIS
Scanlan® Super Cut™ Scissors have a unique asymmetric blade design that combines a razor edge with a scissors edge to provide a clean cut, and prevents pinching or slipping of tissue.
These scissors are handcrafted by artisans to ensure superior balance and tactile feel, thus providing the ultimate in cutting precision and control.
VATS ProceduresMIS Procedures
nn Used for dissection of fine tissue.
n Suggested for opening the pericardium.
VATS ProceduresMIS Procedures
n The rounded blunt blade ends of the 9909-910SC make this a very useful scissors for blunt dissection when isolating the vein, artery and bronchus; if desired, the ends can be made even more blunt if specified at the time of order.
nn Suggested for fibrous tissue and to excise the valve.
nn Wide blade design suggested for very fibrous tissue during decortication procedures and to excise calcified valves.
SCANLAN®
Chitwood Dissecting ScissorsDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
SCANLAN®
Metzenbaum Scissors
Cat . No . Description Shaft
Working Length
Total Length
9009-716SCStraight fine blades1 cm blade length Blunt micro tips
5 mm
6 1/2” (16.5 cm)
10 1/2” (27 cm)
9009-718SCCurved Fine Blades1 cm Blade Length Blunt Micro Tips
6 1/2” (16.5 cm)
10 1/2” (27 cm)
9009-738SC
Chitwood dissecting scissorsCurved blades3 cm blade lengthBlunt tips
7 1/4” (18.5 cm)
11 1/2” (29 cm)
Cat . No . Description Shaft
Working Length
Total Length
9909-910SCCurved blades3.5 cm blade lengthBlunt tips
10 mm 7 3/4” (19.5 cm)
11 1/2” (29 cm)
9909-911SCCurved wide blades3.5 cm blade lengthBlunt tips
9009-716SC
9009-738SC
9009-718SC
9909-910SC
9909-911SC
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 38 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 39 –
SCANLAN®
Axial Handle ForcepsVATS MIS
VATS ProceduresMIS Procedures
nn Shorter length optimized for:
nn Smaller frame patients
n MIS cardiac procedures
n Uniportal VATS procedures
nn Conventional open procedures in large patients and/or deep surgical sites.
nn Lower profile, lighter weight, 8 mm diameter diamond knurling provides a secure grip.
nn Jaw style: 2.5 mm width, 1x2 DeBakey jaws.
VATS ProceduresMIS Procedures
nn Innovative, ergonomic handle design provides superior balance and feel.
nn Perfect for surgeons who prefer thoracoscopic instruments that allow them to “roll the handles between their fingertips.”
nn All forceps styles are available with or without ratchets.
nn DeBakey Jaws – Used to atraumatically grasp and manipulate soft tissue. Available in 3 different widths for delicate to heavier tissue: 1.5 mm, 2.5 mm and 3.5 mm.
nn Russian Jaws – Used to atraumatically grasp and manipulate soft tissue.
nn Resano Jaws – The multi-tooth tips are used to securely grasp and manipulate fibrous or calcified tissue.
nn Platform Jaws – Used during suturing, – the slightly raised area on each tip provides a platform that facilitates both grasping the needle as it exits the tissue and passing it to the needle holder. DIAMOND DUST™ is “needle friendly” and will not burr or score needles and it can also be used to atraumatically grasp tissue.
SCANLAN®
Axial Handle Forceps
SCANLAN®
Axial Handle Forceps
Cat . No . Description Shaft
Working Length
Total Length
9009-528 2.5 mm width DeBakey jaws Without ratchet 5 mm 6 1/4”
(16 cm)12 1/2” (32 cm)
Cat . No . Description Shaft
Working Length
Total Length
9009-510 2.5 mm width Resano jawsWithout ratchet
5 mm 8” (20 cm)
14 1/4” (36 cm)
9009-511 2.5 mm width Resano jawsWith ratchet
9009-512 6 mm width Russian jaws Without ratchet
9009-513 6 mm width Russian jawsWith ratchet
9009-516 2 mm width Platform DIAMOND DUST™ jawsWithout ratchet
9009-517 2 mm width Platform DIAMOND DUST™ jawsWith ratchet
9009-520 1.5 mm width DeBakey jawsWithout ratchet
9009-521 1.5 mm width DeBakey jawsWith ratchet
9009-522 2.5 mm width DeBakey jaws Without ratchet
9009-523 2.5 mm width DeBakey jaws With ratchet
9009-524 3.5 mm width DeBakey jawsWithout ratchet
9009-525 3.5 mm width DeBakey jawsWith ratchet
9009-510 9009-511
9009-5129009-513
9009-5169009-517
9009-5209009-521
9009-5249009-525
9009-5229009-5239009-528
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 40 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 41 –
SCANLAN®
Spring Style Forceps
SCANLAN®
Spring Style Needle Holders
VATS MIS
VATS MIS
VATS ProceduresMIS Procedures
nn Jacobson spring-style handle design.
nn DeBakey Jaws – Used to atraumatically grasp and manipulate soft tissue.
nn Available in 2 different widths for delicate to slightly heavier tissue: 1 mm and 2 mm.
VATS ProceduresMIS Procedures
nn Jacobson spring-style handle design.
nn Scanlan® DIAMOND DUST™ jaws provide a very secure grip on the most delicate needles yet won’t burr or damage them.
SCANLAN®
Jacobson Spring Style Forceps Cat . No . Description Shaft
Working Length
Total Length
9009-420 1 mm width straight DeBakey jawsWithout ratchet
5 mm 7 3/4” (19.5 cm)
16” (41 cm)
9009-422 2 mm width straight DeBakey jawsWithout ratchet
9009-420
9009-648
9009-422
9009-650
SCANLAN®
Jacobson Spring Style Needle Holders Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-648 Straight DIAMOND DUST™ jawsWith ratchet 5-0
andSmaller
5 mm 6 1/2” (16.5 cm)
15 3/8” (38.5 cm)
9009-650 Curved DIAMOND DUST™ jawsWith ratchet
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 42 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 43 –
SCANLAN®
Ring Handle Needle HoldersVATS MIS
VATS ProceduresMIS Procedures
nn Shorter length optimized for:
nn Smaller frame patients
n MIS cardiac procedures
n Uniportal VATS procedures
nn Conventional open procedures in large patients and/or deep surgical sites
nn Lower profile, lighter weight, 7 mm shaft design.
nn Carbon-Inlay Jaws – provides a very secure grasp of larger sized needles.
nn Straight or curved jaws.
nn Gold ring handles.
VATS ProceduresMIS Procedures
nn Shorter length optimized for:
nn Smaller frame patients
n MIS cardiac procedures
n Uniportal VATS procedures
nn Conventional open procedures in large patients and/or deep surgical sites
nn Lower profile, lighter weight, 5 mm shaft design.
nn Scanlan® DIAMOND DUST™ jaws provide a very secure grip on the most delicate needles yet won’t burr or damage them.
SCANLAN®
Ring Handle Needle Holders
SCANLAN®
Ring Handle Needle Holders
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-636
Straight jawsCarbon-inlay jawsGold ring handleWith ratchet 4-0
andSmaller
7 mm 6 1/4” (16 cm)
11 1/4” (28.5 cm)
9009-637
Curved jawsCarbon-inlay jawsGold ring handleWith ratchet
9009-638
Straight jawsCarbon-inlay jawsGold ring handleWith ratchet 2-0
andSmaller
9009-639
Curved jawsCarbon-inlay jawsGold ring handleWith ratchet
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-618Straight jawsFine DIAMOND DUST™ jawsWith ratchet
5-0 and
Smaller5 mm 6 1/2”
(16.5 cm)10 1/2” (27 cm)
9009-636
9009-637
9009-638
9009-639
9009-618
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 44 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 45 –
SCANLAN®
Ring Handle Needle HoldersVATS MIS
VATS ProceduresMIS Procedures
nn These ring handle needle holders have the balance and confident feel of conventional ring handle needle holders.
nn Carbon-Inlay Jaws – provides a very secure grasp of the needle, even when driving the needle through fibrous or calcified tissue.
nn Straight and curved jaw styles.
nn Gold ring handles.
VATS ProceduresMIS Procedures
nn These ring handle needle holders have the balance and confident feel of conventional ring handle needle holders.
nn Carbon-Inlay Jaws – provides a very secure grasp of the needle, even when driving the needle through fibrous or calcified tissue.
nn Straight and curved jaw styles.
nn Gold ring handles.
9909-610
9909-612
9009-640
9009-642
SCANLAN®
Ring Handle Needle Holders
SCANLAN®
Ring Handle Needle Holders
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9909-610
Straight jawsCarbon-inlay jawsGold ring handleWith ratchet 2-0
andSmaller
10 mm 8 1/4” (21 cm)
13 1/2” (34 cm)
9909-612
Curved jawsCarbon-inlay jawsGold ring handleWith ratchet
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-640
Straight jawsCarbon-inlay jawsGold ring handleWith ratchet 4-0
andSmaller
7 mm 8 1/2” (21.5 cm)
13 1/2” (34 cm)
9009-642
Curved jawsCarbon-inlay jawsGold ring handleWith ratchet
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 46 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 47 –
SCANLAN®
Axial Handle Needle HoldersVATS MIS
MIS Procedures
n Innovative, ergonomic handle design provides superior balance and feel.
n Perfect for surgeons who prefer thoracoscopic instruments that allow them to “roll the handles between their fingertips.”
n Scanlan® DIAMOND DUST™ jaws provide a very secure grip on the most delicate needles yet won’t burr or damage them.
n Straight and curved jaw styles.
n Available with or without ratchets.
VATS ProceduresMIS Procedures
nn Innovative, ergonomic handle design provides superior balance and feel.
nn Perfect for surgeons who prefer thoracoscopic instruments that allow them to “roll the handles between their fingertips.”
nn Scanlan® DIAMOND DUST™ jaws provide a very secure grip on the most delicate needles yet won’t burr or damage them.
nn Straight and curved jaw styles.
nn Available with or without ratchets.
SCANLAN®
Axial Handle Needle Holders
SCANLAN®
Axial Handle Needle Holders
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-540 Straight DIAMOND DUST™ jawsWithout ratchet
7-0and
Smaller5 mm 8”
(20 cm)14 3/8”
(36.5 cm)
9009-541 Straight DIAMOND DUST™ jawsWith ratchet
9009-542 Curved DIAMOND DUST™ jawsWithout ratchet
9009-543 Curved DIAMOND DUST™ jawsWith ratchet
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-550 Straight DIAMOND DUST™ jawsWithout ratchet
5-0and
Smaller6 mm 8”
(20 cm)14 3/8”
(36.5 cm)
9009-551 Straight DIAMOND DUST™ jawsWith ratchet
9009-552 Curved DIAMOND DUST™ jawsWithout ratchet
9009-553 Curved DIAMOND DUST™ jawsWith ratchet
9009-5409009-541
9009-5509009-551
9009-5429009-543
9009-5529009-553
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 48 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 49 –
SCANLAN®
Axial Handle Needle HoldersVATS MIS
VATS ProceduresMIS Procedures
nn Innovative, ergonomic handle design provides superior balance and feel.
nn Perfect for surgeons who prefer thoracoscopic instruments that allow them to “roll the handles between their fingertips.”
nn Carbon-Inlay Jaws – provides a secure grasp of the needle, even when driving the needle through fibrous or calcified tissue.
nn Gold-tipped handles.
nn Straight and curved jaw styles.
nn Available with or without ratchets.
VATS ProceduresMIS Procedures
nn Innovative, ergonomic handle design provides superior balance and feel.
nn Perfect for surgeons who prefer thoracoscopic instruments that allow them to “roll the handles between their fingertips.”
nn Carbon-Inlay Jaws – provides a secure grasp of the needle, even when driving the needle through fibrous or calcified tissue.
nn Gold-tipped handles.
nn Straight and curved jaw styles.
nn Available with or without ratchets.
SCANLAN®
Axial Handle Needle Holders
SCANLAN®
Axial Handle Needle Holders
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-570Straight Carbon-inlay jaws jawsGold tipped handleWithout ratchet
2-0and
Smaller7 mm 8”
(20 cm)14 3/8”
(36.5 cm)
9009-571Straight Carbon-inlay jaws jawsGold tipped handle With ratchet
9009-572Curved Carbon-inlay jaws jawsGold tipped handle Without ratchet
9009-573Curved Carbon-inlay jaws jawsGold tipped handle With ratchet
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-560Straight carbon-inlay jawsGold tipped handleWithout ratchet
4-0and
Smaller7 mm 8”
(20 cm)14 3/8”
(36.5 cm)
9009-561Straight carbon-inlay jawsGold tipped handle With ratchet
9009-562Curved carbon-inlay jawsGold tipped handle Without ratchet
9009-563Curved carbon-inlay jawsGold tipped handle With ratchet
9009-5709009-571
9009-5729009-573
9009-5609009-561
9009-5629009-563
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 50 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 51 –
SCANLAN®
Chitwood Knot PusherDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
MIS Procedures
n Cardiac surgeons prefer the smaller footprint of the mini “Trap Model” design.
n Enables the surgeon to securely tie knots in deep operative fields through small incisions.
n The “Trap Model” design securely holds suture during the tying procedure and prevents the suture from slipping out.
n The smooth edges of the “Trap Model” prevent the suture from fraying during the knot tying procedure.
n Pediatric, adult and robotic lengths.
n Easily fits through a 12 mm endo-port.
SCANLAN®
Chitwood Knot Pusher Mini “Trap Model” Developed in cooperation with W. Randolph Chitwood Jr. , MD Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-827-11Mini “Trap Model”Pediatric Short Handle
2-0and
Smaller5 mm
5 1/8” (13 cm)
11” (28 cm)
9009-827-12 Mini “Trap Model”Pediatric and Small Frame Patients
5 1/2” (14 cm)
12” (30.5 cm)
NEW 9009-827-13 Mini “Trap Model” 6 3/4”
(17 cm)13 5/8”
(34.6 cm)
NEW 9009-827-15 Mini “Trap Model” 8 1/2”
(21.5 cm)15 3/8”
(39.1 cm)
9009-827-11 9009-827-129009-827-139009-827-15
Secure The "Trap Model"
design securely holds suture during the tying procedure and prevents suture from slipping out.
9009-827-12
9009-827-13
9009-827-15
9009-827-11
MIS
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 52 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 53 –
VATS
9009-8289009-828-159009-828-16
9009-828
9009-828-16
9009-828-15
Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-828 Original “Trap Model”
2-0and
Smaller5 mm
6 1/8” (15.5 cm)
12 1/2” (32 cm)
NEW 9009-828-15 Original “Trap Model” 8 1/2”
(21.5 cm)15 3/8”
(39.1 cm)
9009-828-16 Original “Trap Model” Long Handle
7 1/4” (18.5 cm)
15 3/4” (40 cm)
SCANLAN®
Chitwood Knot PusherDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
VATS ProceduresMIS Procedures
n VATS surgeons prefer the original “Trap Model” design.
nn Enables the surgeon to securely tie knots in deep operative fields through small incisions.
nn The “Trap Model” design securely holds suture during the tying procedure and prevents the suture from slipping out.
nn The smooth edges of the “Trap Model” prevent the suture from fraying during the knot tying procedure.
nn Adult and robotic lengths.
Secure The "Trap Model"
design securely holds suture during the tying procedure and prevents suture from slipping out.
SCANLAN®
Chitwood Knot Pusher Original “Trap Model” Developed in cooperation with W. Randolph Chitwood Jr. , MD
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 54 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 55 –
SCANLAN®
Chitwood Super Cut ™ Suture CutterDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
VATS MIS
VATS ProceduresMIS Procedures
nn Enables surgeon to confidently and safely cut sutures in deep operative fields through small incisions.
nn Safety – the thickness of the footplate prevents inadvertently cutting the knot, and ensures the suture tags above the knot will always be the appropriate length.
nn Safety – the footplate design prevents inadvertently cutting any surrounding tissue.
nn The “Trap Model” design securely holds the suture when it is cut.
nn The Super Cut™ cutting mechanism ensures a clean suture cut without fraying.
nn The small profile “Trap Model” design easily fits into confined spaces.
nn Adult and robotic lengths.
nn Easily fits through a 12 mm endo port.
SCANLAN®
Chitwood Super Cut™ Suture CutterDeveloped in cooperation with W. Randolph Chitwood Jr. , MD Cat . No . Description
Suture Size Shaft
Working Length
Total Length
9009-838SC
Trap Model”2-0
andSmaller
5 mm
7” (18 cm)
11” (28 cm)
9009-840SC 9” (23 cm)
13” (33 cm)
9009-842SC 11” (28 cm)
15” (38 cm)
Safety• The thickness of the
footplate prevents inadvertently cutting the knot, and ensures the suture tags above the knot will always be the appropriate length.
• The footplate design prevents inadvertently cutting any surrounding tissue.
9009-838SC9009-840SC9009-842SC
9009-838SC
9009-840SC
9009-842SC
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 56 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 57 –
SCANLAN®
Wolf Suction InstrumentsDeveloped in cooperation with Randall K. Wolf, MD
VATS MIS
VATS ProceduresMIS Procedures
nn Curved low profile shaft design developed for VATS and MIS procedures.
nn Blunt Yankauer style suction tip provides effective suction and can safely be used for dissection.
nn Yankauer handle provides familiar, yet secure grip.
nn Pediatric (17 cm) and adult (22 cm) working lengths.
nn Option of with or without fingertip controlled suction regulator.
nn NEW More robust 3.2 to 5 mm shaft
SCANLAN®
Wolf Suction InstrumentDeveloped in cooperation with Randall K. Wolf, MD Cat . No . Description Shaft
Working Length
Total Length
9009-908Pediatric Curved blunt tip 6 mm width tip
3.2 mm
6 3/4” (17 cm)
12 1/4” (31 cm)
9009-909
Pediatric Variable suction Curved blunt tip 6 mm width tip
9009-910 Curved blunt tip 6 mm width tip
8 3/4” (22 cm)
14 1/4” (36 cm)
9009-911Variable suction Curved blunt tip 6 mm width tip
NEW 9009-912
Curved blunt tip 6 mm width tip 3.2 mm
to5 mm
8 3/4” (22 cm)
14 1/4” (36 cm)
NEW 9009-913
Variable suction Curved blunt tip 6 mm width tip
Enlarged to show detail
Designed with a unique tear-shaped port. The variable suction regulator allows for variable suction control.
9009-9089009-9099009-9109009-9119009-9129009-913
Variable Suction Regulator9009-909, 9009-911
9009-908
9009-910
9009-912
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 58 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 59 –
SCANLAN®
Dennis Suction InstrumentsVATS MIS
VATS ProceduresMIS Procedures
nn 5 mm shaft and larger tip opening won’t clog during procedure.
nn Blunt Yankauer style suction tip provides effective suction and can be used as a dissector.
nn Yankauer style handle provides a familiar, yet secure grip.
nn Option of 22 cm or 32 cm working lengths.
nn Option of with or without fingertip controlled suction regulator.
Cat . No . Description Shaft
Working Length
Total Length
9009-914 Curved blunt tip 7.5 mm width tip
5 mm
8 3/4” (22 cm)
14 1/4” (36 cm)
9009-915Variable suction Curved blunt tip 7.5 mm width tip
9009-916 Curved blunt tip 7.5 mm width tip
12 1/2” (32 cm)
17 3/4” (45.5 cm)
9009-917Variable suction Curved blunt tip 7.5 mm width tip
Designed with a unique tear-shaped port. The variable suction regulator allows for variable suction control.
Enlarged to show detail
SCANLAN®
Dennis Suction Instrument
9009-9149009-9159009-9169009-917
Variable Suction Regulator9009-915, 9009-917
9009-915
9009-917
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 60 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 61 –
SCANLAN®
D’ Amico Suction Instruments Developed in cooperation with Thomas A. D’Amico, MD
SCANLAN®
Suction Accessories
VATS MIS
VATS MIS
Enlarged to show detail
Enlarged to show detail
Not actual length
Designed with a unique tear-shaped port. The variable suction regulator allows for variable suction control.
Variable Suction Regulator9009-920, 9009-921
VATS ProceduresMIS Procedures
n Tip is blunted so it can be safely used as a dissector.
nn Side holes at distal end provide gentle, yet very functional suction.
nn 5 mm shaft and tip opening will not clog during procedure.
nn Yankauer handle provides familiar, yet secure grip.
nn Option of with or without fingertip controlled suction regulator.
VATS ProceduresMIS Procedures
n VATS drainage of empyema and decortication procedures.
nn Drainage of large hematoma and clots.
n Tip is blunted so it can be safely used for dissection.
n Sturdy design facilitates decortication.
nn Yankauer handle provides familiar, yet secure grip.
nn Fits on standard suction tubing.
nn Option of with or without fingertip controlled suction regulator.
Cat . No . Description Shaft
Working Length
Total Length
9009-900 Straight blunt tip 5 mm width tip
5 mm 12 1/2” (32 cm)
17 3/4” (45.5 cm)
9009-901Variable suction Straight blunt tip 5 mm width tip
Cat . No . Description Shaft
Working Length
Total Length
9009-920 Straight blunt tip 10 mm width tip
10 mm 12 1/2” (32 cm)
17 3/4” (45.5 cm)
9009-921Variable suction Straight blunt tip10 mm width tip
Cat . No . Description
Total Length
9009-905Brush set, pack of 10, for 5 mm D’Amico and 3.2 mm Wolf and Dennis suction instruments 19”
(48.3 cm)
9009-922 Brush set, pack of 10, for 10 mm D’Amico suction instruments
SCANLAN®
D’Amico Suction InstrumentDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN®
D’Amico Suction InstrumentDeveloped in cooperation with Thomas A. D’Amico, MD
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 62 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 63 –
VATSSCANLAN®
Dennis Rib Cutter
9909-900
VATS and Open Thoracotomy Proceduresn May be used for:
n Chest wall resections
n First rib resections
n Resecting the costal cartilage during some Pectus procedures
n Smooth feeling cutting mechanism provides clean, sharp cuts
n Safety – the blade is centered on the footplate minimizing the possibility of inadvertently cutting tissue surrounding the rib or costal cartilage
n 0-6 cm ruler on the distal end of the instrument
n Fits through a 15 mm incision Cat . No . Description Shaft
Working Length
Total Length
NEW 9909-900
10 mm blade 16 mm cutting width 10 mm 11 1/2”
(29 cm)13 1/2” (34 cm)
SCANLAN®
Dennis Rib Cutter
10 mm15 mm
16 mm
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 64 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 65 –
SCANLAN®
Stern™ Chest Tube Passer VATS MIS
VATS ProceduresMIS Procedures
nn Specifically designed to securely grasp chest tubes to exteriorize them through the chest wall.
nn Two lengths to accommodate a wide range of patient anatomy.
nn Available with and without ratchet.
Cat . No . Description Shaft
Working Length
Total Length
4004-185 Without ratchet
10 mm
6 7/8” (17.5 cm)
9 3/4” (24.8 cm)
4004-186 With ratchet
4004-189 Without ratchet 11” (28 cm)
14” (35.6 cm)
Cat . No . Description Shaft
Working Length
Total Length
9009-816 Straight 1.75 mm tip
3.1 mm 7 1/2” (19 cm)
11 1/2” (29 cm)
9009-820 Straight3.1 mm tip
SCANLAN®
Stern Chest Tube Passer
SCANLAN®
Chitwood Suture PullerDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
SCANLAN®
Chitwood Suture PullerDeveloped in cooperation with W. Randolph Chitwood Jr. , MD
MIS
4004-1854004-1864004-189
9009-816
9009-820
MIS Procedures
n Used during MIS procedures to exteriorize pericardial sutures through the chest wall.
n Selection of two sizes:
n 1.75 mm tapered tip for 4-0 and smaller suture.
n 3.1 mm tip for 2-0 and smaller suture.
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 66 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 67 –
SCANLAN®
Valued Instrument Protection (V.I.P.™) Sterilization Trays
SCANLAN®
Valued Instrument Protection (V.I.P.™) Sterilization Trays
VATS MIS VATS MIS
nn Aluminum metal tray, silver-gray color.
nn Holds up to 20+ VATS / MIS instruments.
nn Tray insert with Scan-Guard™ silicone mat provides flexibility for positioning instruments in tray.
nn Recessed handle design is wrap-friendly and also makes it easier to stack trays in storage.
nn Single heavy duty, long-lasting ratchets on each side are glove-friendly and enable faster removal and securing of the lid.
nn Scan-Guard™ brackets in base have multiple vertical slots specifically designed to layer VATS / MIS instruments. The alternating 5 and 10 mm vertical slots enable the maximum storage of VATS / MIS instruments.
nn Sterilization compatibility: Conventional steam or Flash (immediate use) sterilization, Ethylene Oxide (ETO) and Plasma (gas) sterilization.
nn Firm sale.
nn Aluminum metal tray, silver-gray color.
nn Holds up to 12 VATS / MIS instruments.
nn Scan-Guard™ silicone brackets in base have multiple vertical slots that enable layering of instruments.
nn Sterilization compatibility: Conventional steam or Flash (immediate use) sterilization, Ethylene Oxide (ETO) and Plasma (gas) sterilization.
nn Heavy duty, long-lasting latches.
nn Firm sale.
Cat . No .
DimensionsW x L x H Notes
2145-03 10 1/2” x 21” x 2 1/2”27 cm x 53 cm x 6.4 cm
Holds up to 12 VATS / MIS instruments Firm sale
Cat . No .
DimensionsW x L x H Notes
2146-03 10 1/4” x 21 3/4” x 4”26 cm x 55.2 cm x 10 cm
Additional tray insert with Scan-Guard™ Silicone mat, holds 20+ VATS / MIS instruments, Firm sale
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 68 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 69 –
VATS MIS VATS MIS
nn Aluminum metal tray, silver-gray color.
nn Holds up to 7 VATS / MIS instruments. (tray depth not sufficient to accommodate full curved instruments such as Harkens.)
nn Scan-Guard™ silicone mat on base provides flexibility for positioning instruments in tray.
nn 2” width Scan-Guard™ silicone mat on cover provides an area that securely holds delicate tips or small instruments and accessories.
nn Sterilization compatibility: Steam (conventional or flash), ETO and Plasma compatible.
nn Heavy duty, long lasting latches.
nn Firm sale.
Cat . No .
DimensionsW x L x H Notes
2139-03 10” x 15” x 1 1/2”25.4 cm x 38 cm x 3.8 cm
Scan-Guard™ silicone mat on base Partial mat on cover Holds up to 7 VATS / MIS instruments Firm sale
SCANLAN®
Valued Instrument Protection (V.I.P.™) Sterilization Trays
SCANLAN®
Valued Instrument Protection (V.I.P.™) Sterilization Trays
nn Aluminum metal tray, silver-gray color.
nn Holds up to 8 VATS / MIS instruments. (tray depth not sufficient to accomodate full curved instruments such as Harkens.)
nn Scan-Guard™ silicone mat provides flexibility for positioning instruments in tray.
nn Recessed handle design is wrap-friendly and also makes it easier to stack trays in storage.
nn Sterilization compatibility: Conventional steam or Flash (immediate use) sterilization, Ethylene Oxide (ETO) and Plasma (gas) sterilization.
nn Heavy duty, long-lasting ratchets.
nn Firm sale.
Cat . No .
DimensionsW x L x H Notes
2150-03 29” x 8 3/8” x 1 1/2”73.7 cm x 21.3 cm x 3.8 cm
Scan-Guard™ silicone mat on base,Holds up to 8 VATS / MIS instruments Firm sale
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 70 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 71 –
SCANLAN®
Instrument Modifications VATS MIS
Modifications to an instrument design to meet your specific needs are available at the time of order. Some of the most common modifications requested are below and photographs of some modifed instruments we have made are shown on this page.
Modifications to instruments are made at the time of order and modified instruments are firm sale.
Common modifications to customize an instrument include:
Jaw / Tip Modifications:
nn Angle jaws / tips
nn Angle and cut down jaws / tips
nn Cut down jaws / tips
Scissor Blade Modifications:
nn Cut down scissor blades
nn Blunt tips on blades
nn Sharpen tips on blades
Shank Modifications:
nn Angle shanks up
nn Angle shanks down
Ratchet Modifications:
nn Remove all ratchets
nn Remove partial ratchets
nn Add ratchets
Length Modifications:
nn Lengthen instrument
nn Shorten instrument
Other Modifications:
nn Modify tension
nn Special etching9909-912-13
Modified to have Jaws Angled and Shanks Angled Down
9009-910SC
Modified to have Shanks Angled Down
9009-522
Modified to have Shanks Angled Down
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 72 –
VATS MISSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive Instruments
Instrument Index Notes
VATS MISSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive Instruments
2139-03. . . . . . . . . . . . . . . . 682145-03. . . . . . . . . . . . . . . . 672146-03. . . . . . . . . . . . . . . . 662150-03. . . . . . . . . . . . . . . . 694004-185. . . . . . . . . . . . . . . 654004-186. . . . . . . . . . . . . . . 654004-189. . . . . . . . . . . . . . . 659009-210. . . . . . . . . . . . . . . 239009-211. . . . . . . . . . . . . . . 239009-212. . . . . . . . . . . . . . . 239009-213. . . . . . . . . . . . . . . 239009-222. . . . . . . . . . . . . . . 199009-223. . . . . . . . . . . . . . . 199009-225. . . . . . . . . . . . . . . 199009-226. . . . . . . . . . . . . . . 159009-227. . . . . . . . . . . . . . . 159009-228. . . . . . . . . . . . . . . 159009-229. . . . . . . . . . . . . . . 139009-230. . . . . . . . . . . . . . . 139009-240. . . . . . . . . . . . . . . 299009-241. . . . . . . . . . . . . . . 299009-250. . . . . . . . . . . . . . . 259009-251. . . . . . . . . . . . . . . 259009-252. . . . . . . . . . . . . . . 259009-253. . . . . . . . . . . . . . . 259009-270. . . . . . . . . . . . . . . 279009-280. . . . . . . . . . . . . . . 279009-281. . . . . . . . . . . . . . . 279009-300. . . . . . . . . . . . . . . . 99009-301. . . . . . . . . . . . . . . . 99009-302. . . . . . . . . . . . . . . . 79009-303. . . . . . . . . . . . . . . . 79009-310. . . . . . . . . . . . . . . . 99009-311. . . . . . . . . . . . . . . . 99009-312. . . . . . . . . . . . . . . . 79009-313. . . . . . . . . . . . . . . . 79009-420. . . . . . . . . . . . . . . 419009-422. . . . . . . . . . . . . . . 419009-510. . . . . . . . . . . . . . . 399009-511. . . . . . . . . . . . . . . 399009-512. . . . . . . . . . . . . . . 399009-513. . . . . . . . . . . . . . . 399009-516. . . . . . . . . . . . . . . 399009-517. . . . . . . . . . . . . . . 399009-520. . . . . . . . . . . . . . . 399009-521. . . . . . . . . . . . . . . 399009-522. . . . . . . . . . . . . . . 399009-523. . . . . . . . . . . . . . . 399009-524. . . . . . . . . . . . . . . 399009-525. . . . . . . . . . . . . . . 399009-528. . . . . . . . . . . . . . . 39
9009-540. . . . . . . . . . . . . . . 479009-541. . . . . . . . . . . . . . . 479009-542. . . . . . . . . . . . . . . 479009-543. . . . . . . . . . . . . . . 479009-550. . . . . . . . . . . . . . . 479009-551. . . . . . . . . . . . . . . 479009-552. . . . . . . . . . . . . . . 479009-553. . . . . . . . . . . . . . . 479009-560. . . . . . . . . . . . . . . 499009-561. . . . . . . . . . . . . . . 499009-562. . . . . . . . . . . . . . . 499009-563. . . . . . . . . . . . . . . 499009-570. . . . . . . . . . . . . . . 499009-571. . . . . . . . . . . . . . . 499009-572. . . . . . . . . . . . . . . 499009-573. . . . . . . . . . . . . . . 499009-618. . . . . . . . . . . . . . . 439009-636. . . . . . . . . . . . . . . 439009-637. . . . . . . . . . . . . . . 439009-638. . . . . . . . . . . . . . . 439009-639. . . . . . . . . . . . . . . 439009-640. . . . . . . . . . . . . . . 459009-642. . . . . . . . . . . . . . . 459009-648. . . . . . . . . . . . . . . 419009-650. . . . . . . . . . . . . . . 419009-716SC . . . . . . . . . . . . 379009-718SC . . . . . . . . . . . . 379009-738SC . . . . . . . . . . . . 379009-816. . . . . . . . . . . . . . . 659009-820. . . . . . . . . . . . . . . 659009-827-11 . . . . . . . . . . . . 519009-827-12 . . . . . . . . . . . . 519009-827-13 . . . . . . . . . . . . 519009-827-15 . . . . . . . . . . . . 519009-828. . . . . . . . . . . . . . . 539009-828-15 . . . . . . . . . . . . 539009-828-16 . . . . . . . . . . . . 539009-838SC . . . . . . . . . . . . 559009-840SC . . . . . . . . . . . . 559009-842SC . . . . . . . . . . . . 559009-900. . . . . . . . . . . . . . . 619009-901. . . . . . . . . . . . . . . 619009-905. . . . . . . . . . . . . . . 619009-908. . . . . . . . . . . . . . . 579009-909. . . . . . . . . . . . . . . 579009-910. . . . . . . . . . . . . . . 579009-911. . . . . . . . . . . . . . . 579009-912. . . . . . . . . . . . . . . 579009-913. . . . . . . . . . . . . . . 579009-914. . . . . . . . . . . . . . . 599009-915. . . . . . . . . . . . . . . 59
9009-916. . . . . . . . . . . . . . . 599009-917. . . . . . . . . . . . . . . 599009-920. . . . . . . . . . . . . . . 619009-921. . . . . . . . . . . . . . . 619009-922. . . . . . . . . . . . . . . 619909-202. . . . . . . . . . . . . . . 239909-203. . . . . . . . . . . . . . . 239909-219. . . . . . . . . . . . . . . 299909-221. . . . . . . . . . . . . . . 299909-222. . . . . . . . . . . . . . . 299909-224. . . . . . . . . . . . . . . 259909-225. . . . . . . . . . . . . . . 259909-226. . . . . . . . . . . . . . . 259909-227. . . . . . . . . . . . . . . 259909-232. . . . . . . . . . . . . . . 319909-234. . . . . . . . . . . . . . . 359909-610. . . . . . . . . . . . . . . 459909-612. . . . . . . . . . . . . . . 459909-900. . . . . . . . . . . . . . . 639909-910SC . . . . . . . . . . . . 379909-911SC . . . . . . . . . . . . 379909-912. . . . . . . . . . . . . . . 319909-912-13 . . . . . . . . . . . . 319909-913. . . . . . . . . . . . . . . 359909-914. . . . . . . . . . . . . . . 339909-915. . . . . . . . . . . . . . . 339909-920. . . . . . . . . . . . . . . 179909-921. . . . . . . . . . . . . . . 179909-922. . . . . . . . . . . . . . . 179909-923. . . . . . . . . . . . . . . 179909-924. . . . . . . . . . . . . . . 179909-926. . . . . . . . . . . . . . . 199909-927. . . . . . . . . . . . . . . 199909-940. . . . . . . . . . . . . . . 219909-946. . . . . . . . . . . . . . . 119909-947. . . . . . . . . . . . . . . 11
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 74 –
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
– 75 –
NotesNotes
VATSVATS MISMISSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive InstrumentsSCANLAN®
VATS / MIS Thoracoscopic / Minimally Invasive Instruments
Inches
1
2
3
4
5
6
7
8
9
10
11
1 2 3 4 5 6 7 8 9 101 2 3 4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Centimeters
SCANLAN INTERNATIONAL, Inc. • One Scanlan Plaza • Saint Paul, Minnesota 55107 • U.S.A. • 800-328-9458 • 651-298-0997 • FAX 651-298-0018©2016 Scanlan International, Inc.
SCANLAN® VATS / MIS Thoracoscopic / Minimally Invasive Instruments
For more information or to place an order,
please contact your local Scanlan representative,
or call...
U.S. & Canada: 800-328-9458 International: 651-298-0997
FAX: 651-298-0018www.scanlaninternational.com
MK-B-VTMI Rev. J