6
Schindler 5500 MRL California Fixtures Compliant with CA Building Code

Schindler 5500 MRL elevator - California fixtures

  • Upload
    others

  • View
    25

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Schindler 5500 MRL elevator - California fixtures

Schindler 5500 MRL California FixturesCompliant with CA Building Code

Page 2: Schindler 5500 MRL elevator - California fixtures

Make your elevator easy to operate for all passengers - helping them locate the elevator and get to their selected destination comfortably. High resolution indicators are easy to read, and energy-efficient operating panels are made from high-quality materials with beautiful finishing options.

Schindler 5500 MRL California FixturesCompliant with CA Building Code

*Swing return also available.**Vandal-resistant fixtures are available in brushed and mirrored stainless steel, as well as brushed bronze.

Hall pushbuttons

Standard Landing FixturesStandard panels, available in white or black glass, give your elevator a contemporary look.

Vandal-Resistant Landing Fixtures**Protect your investment: optional vandal-resistant fixtures are engineered to withstand even the most challenging environments.

Car operating panel*

Floor position indicator

Firefighters Service indicator

Emergency lamp

Floor call buttons

Phone

Independent service key

Run/Stop

Door open/closeHoistway access enable key

Vandal-resistant car operating panel*

Vertical combination hall lantern and position indicator

Hall pushbuttonsVertical combination hall lantern and position indicator

Page 3: Schindler 5500 MRL elevator - California fixtures

3 Schindler 5500 CA Fixtures

Schindler 5500 MRL FixturesStandard dimensions

Wall-mounted landing fixturesBox cutout depth = 2 3/4” (70mm)

Standard fixtures can be wall or jamb mounted.

Jamb-mounted landing fixtures, flush in frameMinimum jamb width = 4” (120mm)

Box

Cut

out =

11

7 /16”

(280

mm

)

Box

Cut

out =

5

15/16

” (1

50m

m)

6 5 /1

6” (1

60m

m)

Box

Cut

out =

5

15/16

” (1

50m

m)

6 5 /1

6” (1

60m

m)

6 5 /1

6” (1

60m

m)

5 1 /8

” (1

30m

m)

3 9/16” (90mm)

Box Cutout = 3 3/16” (80mm)

3 9/16” (90mm)

Box Cutout = 3 3/16” (80mm)

Vertical Combination Hall Lantern and Position Indicator

Main Landing Pushbuttons and Fire Service Switch

IntermediatePushbuttons

TerminalPushbuttons

3 9/16” (90mm)

Box

Cut

out =

11

1 /16”

(280

mm

)

11

7 /16”

(290

mm

)

3 9/16” (90mm)

Box Cutout = 3 3/16” (80mm)

Box Cutout = 3 3/16” (80mm)

Car operating panel

2

1HLL

3

54

76

98

Var

ies

with

doo

r hei

ght*

*

11 7/8” (300mm)*

48”

(122

0mm

) Max

. Pus

hbut

ton

Hei

ght

2’-1

1 1 /

16”

(890

mm

) Min

. To

Emer

genc

y C

ontr

ols

FIREFIGHTERS’ORERATION

2’-2

5 /8”

(677

mm

) To

Car

d Re

ader

Note: Car operating panels available as full swing or flush mount. Card reader and service cabinet optional.*Car operating panel width can be 11 7/8” (300mm) or 13 3/4” (350mm) depending on the number of buttons.**Door heights are 7’ (2134mm), 8’ (2438mm), or 9’ (2743mm). Door height options vary by configuration, pleasecontact your local Schindler sales representative.**

2 1/4” (59mm)

Equa

l to

door

hei

ght*

*

Main Landing Pushbuttons and Fire Service Switch

IntermediatePushbuttons

TerminalPushbuttons

Vertical Combination Hall Lantern and Position Indicator

3 9/16” (90mm)

Box

Cut

out =

11

1 /16”

(280

mm

)

11

7 /16”

(290

mm

)

Box Cutout = 3 3/16” (80mm)

2 9/16”(65mm)

6 5 /1

6” (1

60m

m)

2 9/16”(65mm)

6 5 /1

6” (1

60m

m)

2 9/16”(65mm)

5 5 /1

6” (1

60m

m)

5 1 /8

” (1

30m

m)

Page 4: Schindler 5500 MRL elevator - California fixtures

4Schindler 5500 CA Fixtures

Schindler 5500 MRL FixturesVandal-resistant dimensions

Vandal-resistant landing fixturesBox Cutout Depth = 3.5” (89mm)

Vandal-resistant fixtures are wall mounted.

Box

Cut

out =

6

9 /16

” (1

67m

m)

7 1 /1

6” (1

80m

m)

4 3/4” (120mm)

Box Cutout = 4 1/8 (105mm)

IntermediatePushbuttons

Box

Cut

out =

1’ 0

9 /16

” (3

19m

m)

1’ 1

3 /16

” (3

35m

m)

4 3/4” (120mm)

Box Cutout = 4 1/8” (105mm)

7 7/8” (200mm)

Box Cutout = 7” (178mm)

Main Landing Pushbuttons and Fire Service Switch

Box

Cut

out =

6

9 /16

” (1

67m

m)

7 1 /1

6” (1

80m

m)

4 3/4” (120mm)

Box Cutout = 4 1/8 (105mm)

TerminalPushbuttons

Box

Cut

out =

1’ 0

9 /16

” (3

19m

m)

1’ 1

3 /16

” (3

35m

m)

Vertical Combination Hall Lantern and Position Indicator

Box

Cut

out =

11

1 /16”

(280

mm

)

11

7 /16”

(290

mm

)

3 9/16” (90mm)

Box Cutout = 3 3/16” (80mm)

48”

(122

0mm

) Max

. Pus

hbut

ton

Hei

ght

2’-1

1 1 /

16”

(890

mm

) Min

. To

Emer

genc

y C

ontr

ols

2’-2

5 /8”

(677

mm

) To

Car

d Re

ader

Equa

l to

door

hei

ght*

*

11 7/8” (300mm)*

Vandal-resistant car operating panel

Note: Car operating panels available as full swing or flush mount. Card reader and service cabinet optional.*Car operating panel width can be 11 7/8” (300mm) or 13 3/4” (350mm) depending on the number of buttons.**Door heights are 7’ (2134mm), 8’ (2438mm), or 9’ (2743mm).**

2 1/4” (59mm)

Page 5: Schindler 5500 MRL elevator - California fixtures

5 Schindler PORT Technology

Schindler PORT TechnologyDestination Dispatching System

Schindler’s PORTs are simple, yet elegant, with a design that will set your elevator lobby apart from any other. Available as an option on the Schindler 5500, PORT comes in a variety of designs to complement any building.

Space Grey

PORT 1

PORT 4

PORT 1 WIDE

PORT 1

PORT 4

PORT 1 WIDE PORT 1

PORT 4

PORT 1 WIDE

Black Titanium White Aluminum

Page 6: Schindler 5500 MRL elevator - California fixtures

BRO

-WF9

81

9 5

500

CA

©

Sch

indl

er E

leva

tor

Cor

pora

tion

Schindler – We Elevate

For more information, including the location of the Schindler office nearest you, please visit:

U.S. Headquarters. Morristown, New JerseyTel. 973.397.6500www.us.schindler.com

Canada Headquarters. Toronto, OntarioTel. 416.332.8280www.ca.schindler.com

Schindler has received renewal to ISO 9001 and ISO 14001 certificates.

Schindler prints with vegetable-based ink on paper containing post-consumer waste fiber.

SchindlerPlan.comElevator and escalator design in minutes

Schindler Plan is an easy-to-use online planning tool that makes it simple to configure your elevator or escalator in minutes. Good elevator or escalator design plays a critical role in the quality of life and work in multi-story buildings. Schindler Plan was developed to enable accurate escalator or elevator preparation early in a project’s life cycle.