| Tanking system for wet rooms.
Recommended for both solid and panel constructions,
especially in wet zone 2 |
March 2016. Replaces previous instructions of August 2014
These installation instructions are part of the following series from SCHÖNOX
1 SCHÖNOX Folie – Installation instructions
2 SCHÖNOX Rollat – Installation instructions
3 Tiling and grouting
| www.schonox.se |
1603
Sika Sverige AB
Customer service: +46 20-88 87 00
Order: [email protected]
Technical service: +46 8-621 79 00
Website: www.schonox.se
Schönox is all you needSchönox is part of Sika, one of the
world's leading companies in the
field of construction chemistry. Our
research and development
department is constantly creating
products which make life simpler
for both professional and do-it-
yourself users. Schönox is a reliable
full-line supplier of construction
products. Its range includes all kinds
of adhesives, levelling products,
sealants and grouts.
All products have environmental
declarations and are quality-assured
to meet the demands of builders,
specifiers, building contractors,
building managers and society as a
whole. Visit schonox.se for more
information about our products and
for a variety of assembly
instructions.
For questions not answered on our
website, consult your dealer.
| SCHÖNOX Rollat – Installation instructions 1 Tomas Sandström
08-621 79 43
Kiruna/Gällivare, Luleå/Boden,
Haparanda/Kalix, Piteå, Skellefteå,
Umeå
2 Johnny Dahl
08-621 79 23
Härnösand/Kramfors, Sollefteå,
Örnsköldsvik, Östersund, Sundsvall,
Hudiksvall/Ljusdal, Bollnäs/Söderhamn
3 Jan Vestin
08-621 89 75
Mora, Borlänge/Falun, Karlstad,
Ludvika, Lindesberg, Gävle/Sandviken
4 Lars Holm
FÖRSÄLJNINGSCHEF/
ENTREPRENAD SVERIGE
08-621 79 31
Michael Brandt
08-621 79 18
Stockholm/Södertälje, Norrtälje,
Enköping, Uppsala, Fagersta, Sala,
Avesta/Hedemora, Gävle/Sandviken
5 Krister Lindroth Wetterstrand
08-621 79 21
Nyköping, Katrineholm, Eskilstuna,
Norrköping, Örebro, Karlskoga,
Kristinehamn/Filipstad, Karlstad,
Säffle/Åmål, Arvika, Västerås, Köping,
Fagersta,Borlänge/Falun, Avesta/
Hedemora
6 Bengt Carlsson
08-621 79 22
Visby, Uddevalla, Trollhättan/
Vänersborg, Mariestad, Lidköping/
Skara, Skövde, Göteborg/Alingsås,
Borås, Falkenberg/Varberg
7 Martin Forssmed
08-621 79 61
Mjölby/Motala, Linköping, Tranås,
Västervik, Eksjö/Nässjö/Vetlanda,
Hultsfred/Vimmerby, Växjö, Ljungby,
Värnamo, Oskarshamn, Kalmar,
Jönköping
8 Greger Paulsson Wiveus
08-621 79 57
Halmstad, Ängelholm, Hässleholm,
Kristianstad, Karlshamn, Karlskrona,
Helsingborg/Landskrona, Eslöv, Malmö
/Lund/Trelleborg, Ystad/Simrishamn
3
1
2
3
3
4
5
6
7
8
3
1603
2
1603
| 4. System products |Quantities for the different products can be easily estimated on our website
What kind of surface do the walls and floor in the
wet room have? The type of tanking system used
will depend on the surface and the wet zone. If there
This installation instruction describes step by step the
different actions necessary for professional installa-
tion of SCHÖNOX Rollat 1 and 2. The systems have
are several types of surface in the wet room, several
different tanking systems may be needed. See table
and drawing for Step 3.
been tested and approved to meet all applicable
requirements and industry regulations.
| 1. Check the surface |
| Five steps to an approved tanking membrane
in wet rooms |
| 2. Check applicable requirements |
SCHÖNOX Rollat 1 and 2 are two tanking systems
approved by Industry Association BKR. They are
also systems which can be used on all surfaces in
the wet room, as they have the highest levels of
reliability and watertightness. The SCHÖNOX range
of approved tanking systems also includes two foil
systems - SCHÖNOX Folie 1 and 2. See separate
installation instruction
| 3. Select the tanking
system |
1 m
Våtzon 1
Våtzon 2
1 m
Våtzon 1
Våtzon 2
Hela golvet är våtzon 1
Wet room zonesThe most exposed surfaces in a wet room are classified as Wet Zone 1. This comprises the whole floor and the walls within at least one metre of the bathtub/shower. Wet Zone 2 comprises the other wall surfaces. If part of the outside wall is in wet zone 1, the whole of the wall must be treated in the same way.Other types of wet room
The floors of WCs, laundry rooms and spaces contain-
ing a water heater, etc. must also be fitted with a
tanking membrane. Regardless of the system
chosen, the tanking membrane must continue at
least 50 mm up the wall.
SURFACE WET ZONE 1 WET ZONE 2
CONSTRUCTION PANELS
Wet room panels X X X X X X
Paper-clad gypsum plaster panels
Filled suspended timber flooring X X X X
SOLID CONSTRUCTION
Concrete and plaster and/or brickwork X X X X X X X X
Penetrating damp SCHÖNOX 1K DS PREMIUM *
* Read more in BBV Regulation 2:1
SCH
ÖN
OX F
OLI
E 1
SCH
ÖN
OX F
OLI
E 1
SCH
ÖN
OX F
OLI
E 2
SCH
ÖN
OX F
OLI
E 2
SCH
ÖN
OX R
OLL
AT
1
SCH
ÖN
OX R
OLL
AT
1
SCH
ÖN
OX R
OLL
AT
2
SCH
ÖN
OX R
OLL
AT
2
PRODUCTS COMMON TO BOTH SYSTEMS
PRODUCT
SEALING TAPE
WetStop Sealing Tape KL
WetStop Sealing Tape SH
INNER AND OUTER CORNERS
WetStop PC Inner Corner
WetStop PC-E Outer Corner
CUFFS
WetStop MP Pipe Cuff 10-24 mm
WetStop MP Pipe Cuff 32-60 mm
WetStop MP Pipe Cuff 70-125 mm
WetStop MP Pipe Cuff 2 x 20-32 mm
WetStop MG Gulley Cuff 370 x 370 mm
WetStop MG Gulley Cuff 250 x 1500 mm
TOOLS
Always use suitable tools as recommended
NOT PERMITTED
NOT PERMITTED NOT PERMITTED
SCHÖNOX ROLLAT 1
PRODUCT
SCHÖNOX KH
SCHÖNOX HA
SCHÖNOX ROLLAT 2
PRODUCT
SCHÖNOX SPR
SCHÖNOX HA
The industry regulations for wet rooms have been
produced by the industry associations – BKR and
Säker Vatten. They are the experts in their field and
their rules must be followed to ensure approval of
the construction. You can find their guidelines on our
website or access them from the QR codes below.
Bygg
keramikrådet
Vattentätavåtrum
Branschregler för kakel och klinker i våtrum. Reglerna är framtagna av Byggkeramikrådet med hänsyn till myndighetskraven i Boverkets byggregler, BFS 2011:6 med ändringar till och med BFS 2011:26, BBR.
BBV Byggkeramikrådets
branschregler för våtrum
BBV
14:1
ers
ätte
r BBV
10:1
1
SÄKER VATTENINSTALLATION
branschregler :
säkervatten.se2011:1
NOT PERMITTEDX X X X XX
5
1603
4
1603
| See also the instruction film on www.schonox.se
For other products in the system, see Page 3 of these installation instructions.
| Product summary
Clean the surface. Absorbent surfaces must be primed with SCHÖNOX KH. Mix according to instructions on the pack.
Apply SCHÖNOX HA to the corner and mount Inner/Outer Corners. Press hard to fix.
Cut suitable lengths of WetStop Sealing Tape. Brush with SCHÖNOX HA and mount Sealing Tape KL. For Sealing Tape SH: mount directly on floor/wall angle.
Seal the edges with SCHÖNOX HA.
Apply SCHÖNOX HA round pipes.
Mount suitably adapted Pipe Cuffs and press hard to fit.
Seal the edges with SCHÖNOX HA.
Position the cutting template on the JAFO floor gulley. Or follow the instructions from the gulley manufacturer.
Remove the protective paper and mount the gulley cuff. Be careful not to allow air pockets or blisters to form.
Roll SCHÖNOX HA onto the walls. Total consumption for coats 1 and 2 is: 1.35 kg/m².
Follow up with first coat to floor. Allow all to dry for about 2 hours.
Roll more SCHÖNOX HA onto the walls.
And the floor. Check consump-tion. Allow to dry for at least 6 hours.
Cut out the hole in the Gulley Cuff. Follow the instructions from the gulley manufacturer.
JAFO: Remove the cutting template.
JAFO: Fit and screw in the clamping ring.
JAFO: Fit the grate. The tiles can now be installed. NB Wait a minimum of 12 hours.
| SCHÖNOX HA
Ready-to-use rubber membrane for waterproofing floors and walls prior to installing ceramic tiles. Tanking system SCHÖNOX Rollat 1 has a vapour resistance of approx. 163,000 s/m. Consumption: 1.35 kg/m².
| SCHÖNOX KH
Reduces absorption in the substrate. Mix according to instructions on the pack. Then pre-treat:
Wet zone 1 – solid constructions, concrete, plaster and/or brickwork.
Wet zone 2 – wet room panels, paper-clad gypsum plaster panels.
Note that SCHÖNOX Rollat 1 requires the specifier or
client to carry out project design for damp proofing on all
substrates/constructions. If this is not possible, one of the
other SCHÖNOX tanking systems must be used.
| Construction elements SCHÖNOX Rollat 1
1 Substrate 2. SCHÖNOX KH 3. Sealing Tape KL, Inner and Outer Corners and Pipe and Gulley Cuffs 4. Sealing 5. SCHÖNOX HA coat 1 6. SCHÖNOX HA coat 2 7. Tile adhesive and tiles 8. Grouting
1
23
8
7
3
4 6
5
3
| 5a. SCHÖNOX Rollat 1 | For both solid and panel constructions, especially in wet zone 2
1 32 4
5 76 8
9 1110 12
13 1514 16
17 18
7
1603
6
1603
For other products in the system, see Page 3 of these installation instructions.
| Product summary
| See also the instruction film on www.schonox.se
Cut out the hole in the Gulley Cuff. Follow the instructions from the gulley manufacturer. JAFO: Remove the cutting template.
JAFO: Fit and screw in the clamping ring.
JAFO: Fit the grate. The tiles can now be installed. NB Wait a minimum of 12 hours.
Roll SCHÖNOX HA onto the walls. Total consumption for coats 1 and 2 is: 1.0 kg/m².
Follow up with first coat to floor. Allow all to dry for about 2 hours.
Roll more SCHÖNOX HA onto the walls.
Roll AquaStop on the floor. Check consumption. Allow to dry for at least 6 hours.
Mount suitably adapted Pipe Cuffs and press hard to fit.
Seal the edges with SCHÖNOX HA.
Position the cutting template on the JAFO floor gulley. Or follow the instructions from the gulley manufacturer.
Remove the protective paper and mount the gulley cuff. Be careful not to allow air pockets or blisters to form.
Apply SCHÖNOX HA to the corner and mount Inner/Outer Corners. Press hard to fix.
Cut suitable lengths of WetStop Sealing Tape. Brush with SCHÖNOX HA and mount Sealing Tape KL. For Sealing Tape SH: mount directly on floor/wall angle.
Seal the edges with SCHÖNOX HA.
Apply SCHÖNOX HA round pipes.
Clean the surface. Apply SCHÖNOX SPR. Total consump-tion for coats 1 and 2 is: 0.25 kg/m².
Continue by rolling SCHÖNOX SPR onto the floor.
Apply SCHÖNOX SPR diagonally to the wall. Check consumption.
Continue by applying SCHÖNOX SPR diagonally to the floor. Allow to dry for at least 2 hours.
| SCHÖNOX HA
Ready-to-use membrane for waterproofing floors, walls and whole wet rooms prior to installing ceramic tiles. Used together with SCHÖNOX SPR. Consumption: 1.0 kg/m².
| SCHÖNOX SPR
Vapour barrier used in conjunction with SCHÖNOX HA. This gives tanking system SCHÖNOX Rollat 2 a vapour resistance of approx. 1,100,000 s/m. The limit value specified by "Boverket" is 1,000,000 s/m. Consumption: 0.25 kg/m².
| Construction elements SCHÖNOX Rollat 2
1 Substrate 2. SCHÖNOX SPR coat 1 3. SCHÖNOX SPR coat 2 4. Sealing Tape KL, Inner and Outer Corners and Pipe and Gulley Cuffs 5. Sealing 6. SCHÖNOX HA coat 1 7. SCHÖNOX HA coat 2 8. Tile adhesive and tiles 9. Grouting
1
2
34
98
4
5 7
6
4
| 5b. SCHÖNOX Rollat 2 | For both solid and panel constructions, especially in wet zone 2
With SCHÖNOX Rollat 2, SCHÖNOX SPR is used as a vapour
barrier. For you as specifier/client, this means that, unlike
SCHÖNOX Rollat 1, you will not need to carry out project
design for damp proofing.
1 32 4
5 76 8
9 1110 12
13 1514 16
17 1918 20