Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
Seal-less Pumps
Condensed Catalog
Due to the Wanner Engineering Continuous Improvement Program, specifications and other data in this catalog are subject to change.
2 • www.Hydra-Cell.com
Wanner Engineering Product Line
Original F/M/D/H & G Series pumpsSee Pages 6 - 11
www.Hydra-Cell.com
T100 Series high-horsepower triplex pumpsSee Pages 14 - 16
Q155 Series high-horsepower quintuplex pumpsSee pages 14 - 15 & 17
www.Hydra-Cell.com/metering
P Series “pulse-less” metering pumpsSee Page 18
MT8 “pulse-less” triplex metering pumpSee Page 19
S Series solenoid metering pumpsSee Page 19
www.StancorPump.comwww.VectorPump.com
Stan-Cor Series ANSI centrifugal pumps
Vector 2000, 3000 & 4000 Series peristaltic pumps
For more information, request catalogs for Stan-Cor and Vector pumps.
ISO 9001: 2015 CERTIFIED
www.Hydra-Cell.com • 3
Hydra-Cell® Provides Versatile, Reliable Performance
Seal-less Design Advantages• Positivedisplacementpumpwithhydraulicallybalanced,unstresseddiaphragms
• Seal-lessdesigncanhandleabrasiveparticulates(upto800micronsinsizedependingonmodel)andsolidsinsuspen-sion
• Widerangeofflowcapacitiesandpressureratingstomeetavarietyofapplicationsinmanyindustries
• Heavy-dutyconstructionforlongservicelifeinharsh conditions
• Flexibleinstallationwithavarietyofmountingconfigurations
• Repeatable,accurateoutputwithsmooth,virtuallypulse-freeflow
• Highefficiency,lowpowerconsumption
• Minimalmaintenance,nomechanicalseals,cups,orpackingtoleak,wear,orreplace
• Canrundrywithoutdamagetothepump
Propane/ Freon Ammonia Polymers Fuels/ D.I.Water Glycols Chlorine Acids/ Glues/ Inks/ Resins Slurries Butane Additives Caustics Adhesives Paints
• Adding
• Blending
• Cleaning
• Cooling
• Coating
Primary Pumping Applications• Dosing
• Filling
• Filtering
• Injecting
• Metering
• Mixing
• Spraying
• Transferring
Materials of Construction Selection• Metallicpumpheadsinseveralmateri-alstohandlehigherpressuresandtoaccommodateSAEorANSIflanges(whereavailable).
• Non-metallicpumpheadstoprocesscor-rosiveoraggressivefluidsatlowerpressures.
• Diaphragmsandcorrespondingo-ringsinvariouselasto-mericmaterials.
• Valveassembliesinawiderangeofmetallicandnon-metallicmaterialstosuitspecificprocessapplications.Includesvalveseats,valves,valvesprings,andvalvespringretainers.
Fluid Handling CapabilityFromthinliquidstohighlyviscousresinsandslurries,Hydra-Cellpumpscanhandlethefullspectrumofprocessfluidswhilemaintaininghigh-efficiencyoperation.Thisincludesnon-lubri-catingfluidsaswellasfluidswithabrasivesthatcandamageordestroyothertypesofpumps.
4 • www.Hydra-Cell.com
Hydra-Cell® Principles of Operation
5
12 3
4
8
67
5
1
2
3
4
8
6
7
Drive Shaft:viaelectricmotor,hydraulicmotor,beltandpulley,etc.
Tapered Roller Bearings:rigidsupport,immersedinlubricatingoilbath
Fixed Angle Cam/Wobble Plate: translatesrotarymotionintolineartothehydrauliccells
Hydraulic Cells (patented):displacediaphragmsviapressurizedoil
Diaphragms:hydraulicbalanced,nostressduringflexing
Inlet Valve Assembly:simpledesign,allowsliquidintopumpchamber
Discharge Valve Assembly:allowsliquidtoflowintopressuredischargeline
C62 Pressure Regulating Valve:controlsoutputpressureandpreventspumpoverload
Patented Kel-Cell® Diaphragm ProtectionKel-CellDia-phragmPositionControl(DPC)technologyprotectsHydra-CellPumpsbysafeguardingthediaphragmsagainstabnormaloradverseconditions(e.g.blockedpipeorfilter,inadequateliquidsupplyordischargepressure).
TheKel-Cellpositioningsystemstabilizesthediaphragmsandvirtuallyeliminatesthepossibilityofincidental diaphragmfailure.Kel-CellisavailablewithHydra-CellmodelsM03/D03/G03/G13,D10/G10,D12/G12,H25/G25,D35/G35,andD66/G66aswellasHydra-CellMeteringSolutionsmodelsP400andP600.
Wobble Plate Models
www.Hydra-Cell.com • 5
12
5
3
4
8 6
7
Hydra-Cell® Principles of Operation
Crank-shaft Models
5
1
2
3
4
8
6
7
Drive Shaft:viaelectricmotor,hydraulicmotor,beltandpulley,etc.
Precision Ball Bearings:rigidsupport,immersedinlubricatingoilbath
Connecting Rods:hardened,precisionground,andpolished
Hydraulic Cells (patented):displacediaphragmsviapressurizedoil
Diaphragms:hydraulicallybalanced,nostressduringflexing
Inlet Valve Assembly: simpledesign,allowsliquidintopumpchamber
Discharge Valve Assembly:allowsliquidtoflowintodischargepressureline
C46 Pressure Regulating Valve (In-line): controlsoutputpressureandpreventspumpoverload
Hydra-CellSeal-lessPumpscrank-shaftmodelsarefeaturedonthesmallerpumps,includingtheF20/G20,M03/D03/G03/G13,andD04/G04Series.
Available Models
6 • www.Hydra-Cell.com
Hydra-Cell® Flow Capacities and Pressure Ratings
Thegraphabovedisplaysthemaximumflowcapacityatagivenpressureforeachmodelseries.Thetablebelowliststhemaximumflowcapacityandmaximumpressurecapabilityofeachmodelseries.
PleaseNote:Somemodelsdonotachievemaximumflowatmaximumpressure.RefertotheindividualmodelPerformancegraphsonsubsequentpagesforpreciseflowandpressurecapabilitiesbyspecificpumpconfiguration.
F/M/D/H Series and G Series Seal-less Pumps
0
500(34)
1000(69)
1500(103)
2000(138)
2500(172)
3000(207)
0 2(7.6)
4(15.2)
6(22.7)
8(30.3)
10(37.9)
12(45.5)
14(53.1)
16(60.6)
18(68.2)
20(75.8)
22(83.4)
24(90.1)
26(98.5)
36(136.4)
38(143.8)
Flow: gallons per minute (liters per minute)
Pres
sure
: pou
nds
per s
quar
e in
ch (b
ar)
68(257.4)
66(249.8)
64(242.3)
F20M03D04D10 D12D15/17H25D35
H25/G25
D04/G04 D15 & D17/G15 & G17
D66/G66M03/G03
D10/G10
D12/G12
F20/G20
D35/G35
Note: G Series Hydra-Cell Seal-less Pumps are the metric versions of the pumps.
1 Ratings are for cam design with the highest flow rate.2 350 psi (24 bar) maximum with PVDF liquid end; 250 psi (17 bar) maximum with Polypropylene liquid end.3 Consult factory for correct component selection for temperatures from 160˚F (71˚C) to 250˚F (121˚C).4 D10/G10 @790 rpm maximum.5 D35/G35 @700 rpm maximum.
Maximum Maximum Maximum Maximum CapacityDischargePressurepsi(bar)OperatingTemperatureF(C)3 InletModel1 gpm(l/min) Non-metallic2 Metallic Non-metallic2 Metallic Pressurepsi(bar)
F20/G20 1.0(3.8) 350(24) 1500(103) 140˚(60˚) 250˚(121˚) 250(17)
M03/G03 3.1(11.7) 350(24) 1200(83) 140˚(60˚) 250˚(121˚) 250(17)
D04/G04 2.9(11.2) N/A 2500(172) N/A 250˚(121˚) 500(34)
D104/G104 4.3(15.1) N/A 1500(103) N/A 250˚(121˚) 250(17)
D10/G10 8.8(33.4) 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
D12/G12 8.8(33.4) N/A 1000(69) N/A 250˚(121˚) 250(17)
D15 & D17/G15 & G17
15.5(58.7) N/A 2500(172) N/A 250˚(121˚) 500(34)
H25/G25 20.0(75.9) 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
D355/G355 23.1(87.5) N/A 1500(103) N/A 250˚(121˚) 250(17)
D35/G35 36.5(138) N/A 1200(83) N/A 250˚(121˚) 500(34)
D66/G66 65.7(248.7) 250(17) 700(48) 140˚(60˚) 250˚(121˚) 250(17)
www.Hydra-Cell.com • 7
F20/G20 SeriesMaximumFlowRate: 1.0gpm(3.8l/min) MaximumPressure: 1500psi(103bar)forMetallicPumpHeads 350psi(24bar)forNon-metallicPumpHeads
F20/G20 close-coupled for 56C frame or IEC 80 footed motors shown. F21/G21 models are shaft driven. F22 models are flexible-coupled to 56C, 143TC and 145TC frame motors; G22 models to IEC 80 - 90 B5 frame motors. Pump head materials include (metallic) Brass, 316L Stainless Steel and Hastelloy C and (non-metallic) Polypropylene and PVDF.
S, B & G cam options based on 10 psi (0.7 bar) inlet pressure.
E-cam
S-cam
G-cam
X-cam
100 psi (7 bar)500 psi (34 bar)1000 psi (69 bar)1500 psi (103 bar)
Gal
lons
Per
Min
ute
Lite
rs P
er M
inut
e
Revolutions Per Minute0 200 400 600 800 1000 1200 1400 1600 1800
1.2
1.0
0.8
0.6
0.4
0
0.2
0
0.8
1.5
2.3
3.0
3.8
4.5
B-cam
100 psi (7 bar)500 psi (34 bar)1000 psi (69 bar)
F20/G20
F21/F22 &G21/G22
M03/G03 SeriesMaximumFlowRate: 3.1gpm(11.7l/min)MaximumPressure: 1200psi(83bar)forMetallicPumpHeads 350psi(24bar)forNon-metallicPumpHeads
M03/G13 close-coupled with Polypropylene pump head. Also available in (metallic) Brass, 316L Stainless Steel, Hastelloy CW12MW and (non-metallic) PVDF pump heads.
12.5
0
11.25
10
8.75
7.5
6.25
5.0
3.75
2.5
1.25
M03-GG03-G
M03-BG03-B
M03-SG03-S
M03-XG03-X
M03-EG03-E
0 200 400 600 800 1000 1200 1400 1600 1800
3.33
3.00
2.66
2.33
2.00
1.66
1.33
1.00
0.66
0.33
0
100 psi (7 bar)500 psi (34 bar)1000 psi (69 bar)1200 psi (83 bar)
Gallo
ns P
er M
inut
e
Lite
rs P
er M
inut
e
Revolutions Per Minute
D03/G03 shaft-driven with 316L Stainless Steel pump head.
Maximum Flow at Designated Pressure
Maximum Flow at Designated Pressure
8 • www.Hydra-Cell.com
M03/G03 Mono-Block SeriesMaximumFlowRate: 3.1gpm(11.7l/min)MaximumPressure: 1000psi(69bar)forMetallicPumpHeads
12.5
0
11.25
10
8.75
7.5
6.25
5.0
3.75
2.5
1.25
100 psi (7 bar)500 psi (34 bar)1000 psi (69 bar)
M03-XG03-X
M03-EG03-E
0 200 400 600 800 1000 1200 1400 1600 1800
Gallo
ns P
er M
inut
e
Lite
rs P
er M
inut
e
3.33
3.00
2.66
2.33
2.00
1.66
1.33
1.00
0.66
0.33
0
Revolutions Per Minute
Mono-Block (M03/G13) close-coupled 316L Stainless Steel pump head. Also available in Brass.
D04/G04 SeriesMaximumFlowRate: 2.9gpm(11.2l/min)MaximumPressure: 2500psi(172bar)forMetallicPumpHeads
D04/G04 shaft-driven with 316L Stainless Steel pump head. Also available in Brass and 304 Stainless Steel pump heads.
0 200 400 600 800 1000 1200 1400 1600 1800
500 psi (34 bar)1500 psi (103 bar)2500 psi (172 bar)
0
12.5
11.25
10
8.75
7.5
6.25
5.0
3.75
2.5
1.25
D04-XG04-X
D04-EG04-E
D04-SG04-S
Gallo
ns P
er M
inut
e
Lite
rs P
er M
inut
e
3.33
3.00
2.66
2.33
2.00
1.66
1.33
1.00
0.66
0.33
0
Revolutions Per Minute
Maximum Flow at Designated Pressure
Maximum Flow at Designated Pressure
www.Hydra-Cell.com • 9
D12/G12 SeriesMaximumFlowRate: 8.8gpm(33.4l/min)MaximumPressure: 1000psi(69bar)forMetallicPumpHeads
D12-IG12-I
D12-SG12-S
D12-EG12-E
D12-XG12-X
100 psi (14 bar)500 psi (34 bar)1000 psi (69 bar)
Lite
rs P
er M
inut
e
Gallo
ns P
er M
inut
e
0 200 400 600 800 1000 1200 1400 1600 1800
10.0
0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
15.1
18.9
22.7
30.3
34.1
37.9
26.5
3.8
7.6
11.4
0
Revolutions Per Minute
Maximum Flow at Designated Pressure
D10/G10 SeriesMaximumFlowRate: 8.8gpm(33.4l/min)MaximumPressure: 1500psi(103bar)forMetallicPumpHeads 350psi(24bar)forNon-metallicPumpHeads
D10/G10 with Cast Iron pump head. Also available in (metallic) Brass, Duplex Alloy 2205, 316L Stainless Steel, Hastelloy CW12MW and (non-metallic) Polypropylene and PVDF pump heads.
0 200 400 600 800 1000 1200 1400 1600 1800
10.0
0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
15.1
18.9
22.7
30.3
34.1
37.9
26.5
3.8
7.6
11.4
0
Gal
lons
Per
Min
ute
Lite
rs P
er M
inut
e
D10-SG10-S
D10-EG10-E
D10-XG10-X
D10-IG10-I
100 psi (7 bar)500 psi (34 bar)1000 psi (69 bar)
Revolutions Per Minute
1500 psi (103 bar) D10-X @ 790 rpmG10-X @ 790 rpm
D10/G10 with 316L Stainless Steel pump head and ANSI flanges.
Maximum Flow at Designated Pressure
D12/G12 equipped with Model C62 Pressure Regulating Valve and Valve/Tube Accessory. Available in Brass, Cast Iron, and 316L Stainless Steel pump heads.
10 • www.Hydra-Cell.com
D15/D17 & G15/G17 SeriesMaximumFlowRate: 15.5gpm(58.7l/min)MaximumPressure: 2500psi(172bar)forMetallicPumpHeads
0 200 400 600 800 1000 1200 1400 1600 1800
12
11
0
10
9
15
14
13
8
7
6
5
4
3
2
1
16
15.1
18.9
22.7
30.3
34.1
37.9
26.5
3.8
7.6
11.4
0
41.6
45.4
49.2
53
56.8
60.6
Gal
lons
Per
Min
ute
Lite
rs P
er M
inut
e
500 psi (34 bar)1500 psi (103 bar)2000 psi (138 bar)
Revolutions Per Minute
2500 psi (172 bar) D15-X/D17-X @ 1150 rpmG15-X/G17-X @ 1150 rpm
D15-E/D17-EG15-E/G17-E
D15-X/D17-XG15-X/G17-X
H25/G25 SeriesMaximumFlowRate: 20.0gpm(75.9l/min)MaximumPressure: 1000psi(69bar)forMetallicPumpHeads 350psi(24bar)forNon-metallicPumpHeads
0 12001000800600400200
15.1
22.7
30.3
37.9
45.4
53.0
60.6
68.1
75.7
83.3
7.6
00
22.0
20.0
18.0
16.0
14.0
12.0
10.0
8.0
6.0
4.0
2.0
H25-EG25-E
H25-XG25-X
H25-SG25-S
H25-IG25-I
250 psi (17 bar)500 psi (34 bar)1000 psi (69 bar)
Gal
lons
Per
Min
ute
Lite
rs P
er M
inut
e
Revolutions Per Minute
H25/G25 with Cast Iron pump head. Also available in (metallic) Brass, Duplex Alloy 2205, 316L Stainless Steel (with ANSI flanges), 316L Stainless Steel, Hastelloy CW12MW and (non-metallic) Polypropylene and PVDF pump heads.
D15/G15 for horizontal installations shown with 316L Stainless Steel pump head.
D17/G15 for vertical mounting (including motor adapter, base plate and oil reservoir) shown with Brass pump head.
Maximum Flow at Designated Pressure
Maximum Flow at Designated Pressure
www.Hydra-Cell.com • 11
D35/G35 SeriesMaximumFlowRate: 36.5gpm(138l/min)MaximumPressure: 1500psi(103bar)forMetallicPumpHeads
D35/G35 with 316L Stainless Steel pump head. Also available in Brass, Cast Iron, Duplex Alloy 2205, 316L Stainless Steel (with ANSI flanges or SAE ports) and Hastelloy CW12MW pump heads.
40.0
0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0 12001000800600400200
250 psi (17 bar)1200 psi (83 bar)
D35-XG35-X
D35-EG35-E
Gal
lons
Per
Min
ute
Lite
rs P
er M
inut
e
Revolutions Per Minute
0
132.5
113.6
94.6
75.7
56.8
37.9
18.9
151.4
1500 psi (103 bar) D35-X @ 700 rpmG35-X @ 700 rpm
Maximum Flow at Designated Pressure
D66/G66 SeriesMaximumFlowRate: 65.7gpm(248.7l/min)MaximumPressure: 700psi(48bar)forMetallicPumpHeads 250psi(17bar)forNon-metallicPumpHeads
0
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0 1000800600400200
200 psi (14 bar)
700 psi (48 bar) D66-XG66-X
Gallo
ns p
er M
inut
e
Lite
rs p
er M
inut
e
Revolutions Per Minute
0
264.9
227.1
189.3
151.4
113.6
75.7
37.9
D66/G66 with Ductile Iron pump head. Also available in (metallic) Brass and 316L Stainless Steel and (non-metallic) Polypropylene pump heads.
Maximum Flow at Designated Pressure
12 • www.Hydra-Cell.com
C Series Pressure Regulating ValvesDesignedforusewithanypositivedisplacementpump,Hydra-CellCSeriespressureregulatingvalvesbypasssystemfluidtopreventexcesssystempressure.Theycanalsobeusedaspressurereliefvalves.
Performance Advantages• Accurateandrepeatable
• Adjustable
• Immediateresponse
• Smooth,chatter-freebypass
• Noexternalspringsormovingparts
• Flow-throughdesignwithminimalpressuresurge
• Heavy-dutyconstruction
• Easytoserviceinplace
Tapered design of the C20 Series valves plunger.
C60 Series valves feature a seal-less diaphragm with a tapered plunger, making the valves ideal for high-pressure requirements and handling dirty fluids.
C22 valve with Brass body (also available in 316L Stainless Steel and Hastelloy CW12MW).
C46 In-line with Brass body.
C62 Seal-less valve with 316L Stainless Steel body (also available in Brass and Hastelloy C).
C46 Off-line with Stainless Steel body (also available in Brass).
C20 SeriesForusewithHydra-Cellmodels D10/G10,D12/G12,H25/G25,andD35/G35.
C46 SeriesForusewithHydra-CellmodelsF20/G20,F21/G21,F22/G22,M03/D03/G03/G13,andM03/G03Mono-Block.
C60 SeriesForusewithHydra-CellmodelsD04/G04,D10/G10,D12/G12,D15/D17&G15/G17,H25/G25,andD35/G35.
www.Hydra-Cell.com • 13
Hydra-Cell® Pumps Accessories and Options
C80 Series Air Bleed Valves
HDD Series (horizontal direct drive) with Orange Coupling Guard, Motor, and Base
HFD Series (horizontal flanged drive) with Flanged Adapter, Motor, and Base
HBD Series (horizontal belt drive) with Belt Pulley Guard, Motor, and Base
Pulsation Dampeners
Control FreakTM
Touch-screen Metering Controller
Controllers
Hydra-Oil Lubricants, Motor Adapters, Oil Reservoir Sight Bottles, Tool Kits, and Couplings
Replacement Parts Kits
14 • www.Hydra-Cell.com
T100
Exclusive Seal-less Diaphragm Design• Seal-lessdesignseparatesthepowerendfromtheprocessfluidend,eliminatingleaks,hazards,andtheexpenseassociatedwithsealsandpacking
• LowNPSHrequirementsallowforoperationwithavacuumconditiononthesuction-positiveinletpressureisnotnecessary
• Canoperatewithaclosedorblockedsuctionlineandrundryindefinitelywithoutdamage,eliminatingdowntimeandrepaircosts
• Uniquediaphragmdesignhandlesmoreabrasiveswithlesswearthangear,screworplungerpumps
• Hydraulicallybalanceddiaphragmstohandlehighpressureswithlowstress
• Provideslow-pulse,linearflowduetoitsmultiplediaphragmdesign
• Lowerenergycoststhancentrifugalpumpsandotherpumptechnologies
• Ruggedconstructionforlonglifewithminimalmaintenance
• Compactdesignanddouble-endedshaftprovidesavarietyofinstallationoptions
Hydra-Cell® T & Q Series Design Advantages
Available to Meet API 674!
Q155
www.Hydra-Cell.com • 15
Hydra-Cell® Flow Capacities and Pressure Ratings
Flow: gallons per minute (l/min)
120(454.2)
150 (567.8)
Pre
ssur
e: p
oun
ds
per
sq
uare
inch
(bar
)
3000 (207)
0
2500 (172)
500 (34)
1000 (70)
1500 (103)
2000 (138)
3500 (241)
4000 (276)
4500 (310)
Q155M
60(227.1)
0 30(113.7)
90(340.7)
Q155K
Q155H
Q155F
Q155E
5000 (345)
T100E
T100F
T100H
T100K
T100M
T100S
T100 Series Triplex Pumps & Q155 Series Quintuplex Pumps
Maximum Discharge Maximum Discharge Maximum Capacity Pressure Maximum Capacity Pressure Model gpm l/min BPD psi (bar) Model gpm l/min BPD psi (bar) T100E 96.0 366.1 3292 1500(103) Q155E 157 595 5383 1500(103) T100F 76.5 289.6 2623 1850(128) Q155F 127 490 4354 1850(128) T100H 68.0 257.8 2332 2100(145) Q155H 111 421 3806 2100(145) T100K 45.0 170.4 1543 3000(207) Q155K 78 295 2674 3000(207) T100M 38.0 143.8 1302 3500(241) Q155M 65 246 2228 3500(241) T100S 26.0 98.4 891 5000(345)Maximum Inlet Pressure for all models: 500 psi (34 bar).Maximum Operating Temperature for all models: 180˚F (82˚C). Consult factory for correct component specification for temperatures above 180˚F (82˚C) or below 40˚F (4˚C)
16 • www.Hydra-Cell.com
Low Pressure ModelModel T100EMaximumFlowRate: 96.0gpm(366.1l/min)3292BPDMaximumPressure: 1500psi(103bar)forMetallicPumpHeads
Model T100FMaximumFlowRate: 76.5gpm(289.6l/min)2623BPDMaximumPressure: 1850psi(128bar)forMetallicPumpHeads
Model T100HMaximumFlowRate: 68.0gpm(257.8l/min)2332BPDMaximumPressure: 2100psi(145bar)forMetallicPumpHeads
High Pressure ModelModel T100S MaximumFlowRate: 26.0gpm(98.4l/min)891BPDMaximumPressure: 5000psi(345bar)forMetallicPumpHeads
Medium Pressure ModelsModel T100KMaximumFlowRate: 45.0gpm(170.4l/min)1543BPDMaximumPressure: 3000psi(207bar)forMetallicPumpHeads
Model T100MMaximumFlowRate: 38.0gpm(143.8l/min)1302BPDMaximumPressure: 3500psi(241bar)forMetallicPumpHeads
High-pressure model with Stainless Steel pump head. Also available in Nickel Aluminum Bronze (NAB).
Medium-pressure model with Nickel Aluminum Bronze (NAB) pump head. Also available in Duplex Alloy 2205, 316L Stainless Steel, and Hastelloy CX2M.
Low-pressure model with Nickel Aluminum Bronze (NAB) pump head. Also available in Duplex Alloy 2205, 316L Stainless Steel, and Hastelloy CX2M.
T100 Series High-horsepower Triplex Pumps Available
to Meet API 674!
www.Hydra-Cell.com • 17
Q155 Series High-horsepower Quintuplex Pumps
Medium Pressure ModelsModel Q155K MaximumFlowRate: 78gpm(295l/min)2674BPDMaximumPressure: 3000psi(207bar)forMetallicPumpHeads
Model Q155M MaximumFlowRate: 65gpm(246l/min)2228BPDMaximumPressure: 3500psi(241bar)forMetallicPumpHeads
Medium-pressure model with Nickel Aluminum Bronze (NAB) pump head. Also available in Duplex Alloy 2205, 316L Stainless Steel, and Hastelloy CX2M.
Low Pressure ModelsModel Q155E MaximumFlowRate: 157gpm(595l/min)5383BPDMaximumPressure: 1500psi(103bar)forMetallicPumpHeads
Model Q155F MaximumFlowRate: 127gpm(490l/min)4354BPDMaximumPressure: 1850psi(128bar)forMetallicPumpHeads
Model Q155H MaximumFlowRate: 111gpm(421l/min)3806BPDMaximumPressure: 2100psi(145bar)forMetallicPumpHeads
Low-pressure model with 316L Stainless Steel pump head. Also available in Nickel Aluminum Bronze (NAB), Duplex Alloy 2205, and Hastelloy CX2M.
Available to Meet API 674!
18 • www.Hydra-Cell.com
0
500(34)
1000(69)
1500(103)
2000(138)
2500(172)
3000(207)
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900
Flow: gallons per hour
Pre
ssu
re: p
ou
nd
s p
er s
qu
are
inch
(bar
)
P600P400
P100
P500
(189) (379) (569) (757) (946) (1136) (1325) (1514) (1703) (1893) (2082) (2271) (2461) (2650) (2839) (3028) (3218) (3407)
P300
P200
Hydra-Cell® P Series Metering Pumps
P100
P Series Flow Capacities and Pressure Ratings
P200 P300
P400 P500 P600
1 Ratings are for X-cam design.2 Flow capacities are based on pump speeds of 3600 rpm for gallons per hour (gph) and 3000 rpm for liters per hour (lph). 3 350 psi (24 bar) maximum with PVDF liquid end; 250 psi (17 bar) maximum with Polypropylene liquid end. 4 Consult factory for correct component selection for temperatures from 160˚F (71˚C) to 250˚F (121˚C).
Maximum MaximumDischarge MaximumOperating Maximum Capacity Pressurepsi(bar) TemperatureF(C)4 InletPressure Model1 gph(lph)2 Non-metallic3 Metallic Non-metallic Metallic psi(bar)
P100 27.0(85.0) 350(24) 1500(103) 140˚(60˚) 250˚(121˚) 250(17)
P200 81.0(255.4) 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
P300 81.4(256.8) N/A 2500(172) N/A 250˚(121˚) 500(34)
P400 242.8(765.9) 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
P500 425.9(1343.5) N/A 2500(172) N/A 250˚(121˚) 500(34)
P600 890.3(2808.0) 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
P Series multiple-diaphragm metering pumps exceed API 675 performance standards for Steady-state accuracy (±1%), Linearity (±3%) and Repeatability (±3%) while providing virtually pulse-free, linear flow.
www.Hydra-Cell.com • 19
Hydra-Cell® MT8 Low-flow Triplex Metering Pump
MinimumFlowRate: 0.06gph(0.227lph)MaximumFlowRate 8.00gph(30.28lph)MaximumPressure: 3500psi(241bar)forMetallicPumpHeads 300psi(20bar)forNon-metallicPumpHeads
ThisgroundbreakingtriplexmeteringpumpisthelatestadditiontotheHydra-CellMeteringSolutionsproductline.Idealforlow-flowrequirements,athighpressures,itfeaturesatriplex-diaphragmdesigntoprovidelinear,virtuallypulse-freeflowwithouttheneedforexpensivepulsationdampeners.
TheMT8exceedsAPI675performancestandardsforSteady-StateAccuracy(±1%),Linearity(±3%)andRepeatability(±3%).
Hydraulically-balancedandactuated,thepumpfeaturesanintegralreliefvalveforaddedsafetyandcartridgecheckvalvesforeaseofmaintenance.
TheMT8isavailablewithmetallic(316SST,HastelloyC, Alloy20)andnon-metallic(PVC,PVDF)liquidendsplusPTFEdiaphragms.Checkvalvematerialsinclude316SST,HastelloyC,andAlloy20.
Hydra-Cell® S Series Metering PumpsTheSSeriespumpsprovideaneconomicalchoiceforchemicalinjectioninmeteringapplications.
Solenoiddriven,theSpumpsfeatureawidedischarge-volumerange,extensivechoiceofliquidendmaterials,variouscontrolfunctions,andawidevoltagerange.
Materialsofconstructionchoicesandversatiledesignoptionsresultinpumpsperfectedforspecificapplicationsincludinggeneralchemicals,high-pressureboiler,high-viscosityfluids,outgassingandmore.
SM030CAS manual control with stroke speed dial. Model shown features Acrylic pump head with automatic air release joint for outgassing fluids.
ST03RPES digital with pulse-input control and timer. ST models offer control options by interval, day, and week.
SA03RPES digital with pulse-input and analog-input. Model shown features an integral relief valve to release abnormal pressure automatically.
SM Series SP/ST/SA Series Flow Rate Models Models 30ml/min* SM030 SP/ST/SA-030
60ml/min SM060 SP/ST/SA-060
100ml/min SM100 SP/ST/SA-100
220ml/min N/A SP/ST/SA-200
With Relief Valve
30ml/min* SM03R SP/ST/SA-03R
60ml/min SM06R SP/ST/SA-06R
100ml/min SM10R SP/ST/SA-10R*High-pressure models have maximum flow rates of either 25 or 28 ml/min. Consult S Series catalog for more information.
SP060HVS digital with pulse-input control. Model shown features PVC pump head for high-viscosity fluids.
With its multiple-diaphragm design, the MT8 provides virtually pulse-free flow.
Printed in USA ©Wanner Engineering, Inc. HC-CCIM/MT08.18RevA
Seal-less Pumps
World Headquarters & ManufacturingWannerEngineering,Inc.1204ChestnutAvenueMinneapolis,MN55403USAPhone:612-332-5681•Fax:612-332-6937Toll-FreeFax(USA):800-332-6812Email:[email protected]
Regional Office207USHighway281WichitaFalls,TX76310USAPhone:940-322-7111Toll-Free:800-234-1384Email:[email protected]
Latin American OfficeR.ÁlvaroAnes,150BairroCampestreSantoAndré/SãoPaulo,Brazil-CEP09070-030Phone:+55(11)4081-7098Email:[email protected]
WannerInternational,Ltd.Hampshire-UnitedKingdomPhone:+44(0)1252816847Email:[email protected]
Wanner Pumps Ltd.
Wanner Pumps Ltd.
Wanner Pumps Ltd.WannerPumps,Ltd.Kowloon-HongKongPhone:+85234286534Email:[email protected]
Shanghai-ChinaPhone:+86-21-68763700Email:[email protected]