Secospace USG2100&2200&5100 V300R001 Quick Start 04

Embed Size (px)

Citation preview

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    1/14

    Secospace USG2100/2200/5100 UnifieV300R001

    Quick Start

    Issue: 04

    Part Number: 3150G2CEDate: 2013-10-15

    This document guides you through quick installation and Internand Internet access configuration. For more information, please

    Before connecting or disconnecting the power cable, turn o

    When connecting and maintaining optical fibers, do not stanaked eyes. Otherwise, the laser emitted from optical fiber

    a e y n orma on

    Install interface cards into matching slots. The slots on the

    is inserted into an unmatching slot, the USG may fail to st

    installing and removing an interface card, ensure that the

    position. Installing and removing interface card during po

    Make sure that the equipment room is under lightening pr

    cons era on, e ev ce may e amage y cer a n g

    When operating the USG, ensure that the device and oper

    damaged. If you need to touch the USG or interface cardend of the strap should be properly connected to the ESD

    Security Gateway

    t access by detailing device appearance, installation procedure,refer to the documentation in the delivered disk.

    ff the power switch. Otherwise, fire or injury may occur.

    nd close to or look into the optical fiber outlet directly withharms your eyes.

    USG can house different interface cards. If an interface card

    rt, or the interface card or USG may be damaged. Before

    evice is powered off; that is, the power switch is in OFF

    er-on may result in damage on the interface card or device.

    tection. Although lightening proof design is taken into

    en ng eyon o erance.

    ting tools are properly grounded. Otherwise, the USG may be

    irectly with your hands, wear the ESD wrist strap. The otherrist strap socket, as shown in the figure.

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    2/14

    Device Overview

    1 Device Appearance

    The USG2100 series, a 1U device, including the USG2160, and US

    The USG2160/USG2160W two MIC slots (SLOT2 and SLOT3) or o

    The USG2160W supports the WiFi function.

    USG2100

    7 4 58 14

    The example uses the USG2160W.

    USG2200

    ,

    When FIC5 is installed with a DFIC interface card, slot FIC6 must b

    USG5120

    The USG5120, a 2U device, supports AC power supply only.When FIC5 or FIC6 is installed with a FIC interface card at the lowe

    DFIC slot for dustproof purpose.

    USG5150

    The USG5150, a 3U device, can host two AC power modules in itsmodules.

    en , , or s ns a e w a n er ace car part of the DFIC slot for dustproof purpose.

    G2160W, supports the AC power supply only.

    e DMIC slot (SLOT2).

    11 2 3

    18

    13 15

    17

    6161

    SLOT2SLOT3

    SLOT1

    . .

    empty.

    r part, a filler panel needs to be installed on the upper part of the

    power slots on the front panel for hot backup of power supply

    a e ower par , a er pane nee s o e ns a e on e upper

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    3/14

    2 Supported Interface Cards

    Slot

    1FE, 1E1, 1CE1, 1SA/2SA, 3G

    WCDMA, 3G-CDMA2000, 3G-SCDMA, 1ADSL2+, WiFi , 5Fand 1/2/4G.SHDSL

    USG2100 SLOT2 No WiFi

    SLOT3 No WiFi

    USG2200 MIC1/MIC2 Y

    MIC3/MIC4 Y

    FIC5 -

    FIC6 -

    USG5120 MIC1/MIC2 Y

    MIC3/MIC4 Y

    FIC5/FIC6 -

    FIC7 -

    FIC8 -

    MIC3/MIC4 YFIC5/FIC6/FIC7/FIC8

    -

    FIC9 -

    FIC10 -

    -

    D-W,

    8FE+

    2GE

    1GE/4GE 2E1/4E1/8E1,

    2CE1/4CE1/8CE1, 2FE+2FECombo, andE4BY

    16GE+4

    SFP,and18FE+2SFP

    Y - - -

    - - - -

    Y - - -

    - - - -

    - Y Y (Except E4BY) Y

    - Y Y (Except E4BY) -

    Y - - -

    - - - -

    - YLower partof the slot

    YLower part ofthe slot

    Y

    - Y Y Y

    - Y Y -

    - - -

    - - - -- Y

    Lower partof the slot

    YLower part ofthe slot

    Y

    - - Y -

    - - Y -

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    4/14

    Installation

    1 Installing the Grounding Cable

    The USG can be installed into a 19-inch cabinet, or placed on an

    1 Connect one end (withthe smaller radius for

    the OT terminal of a 1Udevice) of the groundingcable to the groundinghole.

    1

    The previous figures take the USG2230 as an example.

    The operations for other models are similar.

    If no inde endent roundin terminal is available for the

    2 Installing the Power Cable

    Installing the AC Power Cable

    grounding cable, ensure that the grounding point of the

    power supply is firmly grounded.

    2

    1 Push the power switch to OFF( O ).

    2 For 3U device

    Insert the other end of the AC power cable into the ACsocket (100 VAC to 240 VAC) in the equipment room.

    3

    insulating and clean workbench.

    2 Fix the other end (withthe larger radius for the

    OT terminal of a 1Udevice) of the groundingcable to the groundingterminal of the cabinet orworkbench.

    2

    Groundin cable Philli s screwdriver

    For 1U and 2U devices

    1U and 2U devices: Insert the cable-retention clip intothe corresponding jack, the AC power cable into the AC

    -

    2

    , .

    3U device: Insert the cable-retention clip into a heatdissipation hole (select one close to the socket as thejack), the AC power cable into the AC socket, and fix thecable with the cable-retention clip.

    AC power cable Cable-retention clip

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    5/14

    3 Installing the Interface Card

    1

    Before installing an interface card, power off the device. M

    swappable. If hot swapped, they may be damaged. This document only covers the installation of certain interfa

    refer to the Installation Guide in the delivered disk.

    Before installing the interface card, wear the ESD wrist strterminal of the wrist strap into the ESD jack of the cabinet

    2

    .

    2 3Loosen the screws of the filler panel on the rearpanel and remove the panel. When installingthe DMIC/DFIC, plug out the two adjacent fillerpanels.

    4

    54 Install the FIC/DFIC: Unfold the ejector handles andpush the interface card along the board track till theejector handles touch the chassis.

    IC, DMIC, FIC, and DFIC interface cards are not hot

    ce cards. For the installation of other interface cards, please

    ap. For the USG2100 and USG2200, insert the groundingor workbench; for the USG5100, insert the grounding terminal

    Install the MIC/DMIC: Push the interfacecard along the board track to fully seatthe panel of the interface card andfasten the ca tive screws.

    ESD wrist strap

    Phillipsscrewdriver

    Install the FIC/DFIC: Push the ejector handles to fullyseat the panel of the interface card and fasten thecaptive screws.

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    6/14

    Power on the power supply device in the equipment room. Pushblinks every two seconds, check the indicators on the front pan

    4 Checking the Installation

    Indicator Descript ion

    SYS PWR(Green)

    On: The power is on.Off: The power is off or the power supply is noin place.

    FLASHCARD

    On: The Flash interface is working normally.Off: The Flash interface is faulty or disconnect

    SYS ACT(Green)

    Blinking every 2s (0.5 Hz): The system is normBlinking twice every 1s (2 Hz) or steady on: Thsystem is starting up.Blinking eight times every 1s (8 Hz): The systeis upgrading its software or configuration file.Off: The system is faulty or powered off.

    WiFi Blinking: Data is being transmitted through the

    only).

    On: The WiFi function is enabled.Off: The WiFi function is disabled.

    the power switch to ON( | ). When the SYS ACT indicatorl according to the following table.

    Indicator Descr iption

    FAN (Green)(ExceptUSG2200)

    On: The fan is working normally.Off: The fan is faulty or not in place.

    d.USB0(USG2100only)

    Blinking: Data is being transmittedthrough the interface.On: The USB interface is connected.

    .

    al.e

    m

    ALM (Red) On: The system is faulty.Blinking every 2s (0.5Hz): A faultoccurs during the upgrade or storagecard loading.Off: The system runs normally.

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    7/14

    Initial Configuration

    1 Network ing and Connection

    The following figures show the typical networking and connectiofollowing takes the USG2160W and USG2230 as an example. T

    USG2200, and thus omitted.

    3G station 3G access

    3G 3/0/0

    Administrator

    Rear panel XDSL2/0/0

    WebTelnet

    Networking of USG2230

    of the device. Please connect your device as required. Thehe networking of the USG5100 is similar to that of the

    WiFi access

    Local user

    Console loginLAN

    192.168.0.1 WANFE0/0/0

    Local userorlogin

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    8/14

    2 Logging in to the Device

    Login Through the Web UI

    Product Port Label Interface

    USG2100LAN (FE1/0/0to FE1/0/7)

    LAN

    USG2200/USG5100 GE0/0/0 GE0/0/0

    Connect the network interface of the PC to the interface with m

    By default, the IP address of LAN or GE0/0/0 is 192.168.0.

    Configure the PC to obtain an IP address automatically; alte

    192.168.0.2/24 to 192.168.0.254/24.

    1. Connect the console cable, with its RJ45 connector to the cthe PC.

    Login Through the CLI

    2. Log in to the USG through the serial port of the PC. HyperT

    1 Choose Start > Programs >Accessor ies > Communica

    2 3

    3. Wait for about two minutes. When Press ENTER to get staradmin and passwordAdmin@123 to enter the configuratio

    Enter the name of the new

    connection and click OK.

    Select the seria

    the console por

    Login Address User Name/Password

    http://192.168.0.1 admin/Admin@123

    http://192.168.0.1 admin/Admin@123

    nagement IP address on the device through a network cable.

    1/24.

    rnatively, manually set an IP address ranging from

    nsole port on the USG and DB9 connector to the serial port on

    Console cable

    rminal is used in this example.

    tions > HyperTerminal.

    4

    ted. is displayed, please press Enterand enter user namepage.

    l port connected to

    t cable, and click OK.

    Click Restore Defaults, and then

    OK.

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    9/14

    Log in to the Web UI, and on the Startup Wizard page click1

    3 Quick Wizard

    On the WAN Mode tab, select a mode (Static IP, DHCP, PThen click Next.

    2

    3

    4

    If the Startup Wizardpage is not displayed upon your login,

    On the Basic Configuration tab, you can change the USG

    On the Time Settings tab, set the time and click Next.

    An interface number varies with device and slot where the int

    5 On the WAN Settings tab, set access parameters and click

    Next.

    PoE/XDSL, and 3G are available) for accessing the Internet.

    choose Wizard > Startup Wizard in the navigation tree.

    name and login password and click Next.

    erface card resides.

    Next.

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    10/14

    When the ADSL interface card is of the single PVC type, you

    1

    do not need to set the VPI and VCI parameters.

    0

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    11/14

    6 On the LAN Settings tab, set LAN parameters and click Ne

    On the USG2100, choose LAN (FE1/0/0 to FE1/0/7) fromspecified by default, and can be modified if desired.) The

    On the USG2200/USG5100, choose GE0/0/0 from the Intspecified by default, and can be modified if desired.) Then

    1

    t.

    the Interface drop-down list. (IP Address and Subnet Mask areclick Next. The settings are as follows:

    rface drop-down list. (IP Address and Subnet Mask areclick Next. The settings are as follows:

    1

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    12/14

    7 On the LAN DHCP Settings tab, enable the DHCPserver function and set available IP address range (therange is specified by default, and can be modified ifdesired). Then click Next.

    8 On the WLAN Settings tab, set the WLAN parameters.Then click Next.

    10

    On the Summary tab, you can view all specified parameter

    On the Startup Wizard Complete page, the system displayFinish.

    9

    You can obtain technical support from Huawei in the following m

    Access http://support.huawei.com/enterprise.

    Contact the local office or agent.

    1 Obtaining Technical Support

    Q: What are the default user name and password for the consol

    A: The default user name is admin, and default password isAdQ: Why does my device not have the expansion interface cardsA: The cards should be purchased separately. You may contact

    2 FAQs

    Q: Why are certain functions described in related documents unA: Certain functions of the USG are subject to license. You maypersonnel.

    1

    Only for the devices that support WiFi function.

    . Confirm the settings and clickApp ly .

    s a message indicating the successful configuration. Click

    ethods:

    port?

    [email protected] in this document?the technical support personnel or agent.

    available on my device?check your license. If it is valid, contact technical support

    2

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    13/14

    Appendix

    A Loading License

    1. Apply for a license: Collect the following information, and se

    This step is optional unless the functions involve license contro

    Contract No: obtained from the license authorization cert

    License Authorization Code (LAC): obtained from the lic

    Equipment Serial Number (ESN): obtained from the upp

    2. Activate a license. Upload the purchased license to the storConfiguration Guide in the delivered disk. Run the license fi

    .TYPE and S/N) of other models are in the same position.

    specified license file.

    B Restoring the Factory Default Setting

    To restore the factory default setting, perform either of the follo

    Log in to the GUI and choose System > Maintenance > CSettings.

    Use the RESET button, for details, see "One-Button Resto

    The following is a list of the default configurations.

    CDefault Settings

    The default IP address of the interface used to manage thLAN (FE1/0/0 to FE1/0/7) on the USG2100, or GE0/0/0 on

    The DHCP service is enabled on the interface which has tIP address allocation is rom 192.168.0.2 24 to 192.168.0.

    The Web based management function is enabled.

    A super administrator is created. The user name and passadministrator authority is 3. This user account is valid for tWeb browser.

    D Obtaining Product Documentation

    The latest documents of all products are published at the techof Huawei Technologies Co., Ltd..

    1

    d the information to [email protected].

    l.

    ificate delivered with the device.

    nse authorization certificate delivered with the device.

    r left corner of the front panel or through the display firewall

    ge device of the USG. For details, please refer to thelelicense-file command in the system view to activate the

    .

    ing:

    nfiguration Management, and click Restore Factory

    ration" in the Installation Guide.

    device is 192.168.0.1/24. The interface with that IP address isthe USG2200 and USG5100.

    e default IP address 192.168.0.1/24. The range for automatic54 24.

    ord are admin andAdmin@123 respectively and thee login through the console port, through Telnet, or through

    ical support website (http://support.huawei.com/enterprise)

    3

  • 8/10/2019 Secospace USG2100&2200&5100 V300R001 Quick Start 04

    14/14

    H

    1

    UAWEI TECHNOLOGIES CO., LTD.

    4

    Huawei Industrial Base Bantian Longgang

    Shenzhen 518129

    Peoples Republic of China

    http://enterprise.huawei.com