SPLIT FLASHINGSSECTION J

A-0

Page 2: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

ROOF SPECIALTIESSPLIT FLASHINGS

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

Thaler Or Equal

SPJ-1 Round Split Flashing

SPJ-2 Round Split Flashing (Vented Cap)

SPJ-3 Square Split Flashing

SPJ-4 Square Split flashing (Vented Cap)

Split Flashing Specification

J-0

J-1, J-1A

J-2, J-2A

J-3

J-4, J-4A

J-5 to J-7

TABLE OF CONTENTS

Page 3: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

THALER OR EQUALWHAT IT TAKES TO BE

When specifications read Thaler or Equal, it is the responsibility of specifiers and building owners to determine what it means to be “Or Equal”. The following data has been presented to quickly help assess the comparative merits of “competitive” products. Thaler Split Flashings products have a number of Value Added features that should be considered when trying to equate the “Or Equal”.

100% Watertight; unlike soldered-type split flashings or pitch pans, Thaler Split Flashings provide an unparal-leled seal and remain flexible enough to allow movement of penetrating items while coping with the vibration often associated with cooling tower supports and similar mechanical equipment.

New-Age flashing; Thaler split flashings are designed to do away with the ultimately expensive, unreliable and high maintenance "pitch pans"; they pose an open threat of leaks and require frequent maintenance checks and repair of bitumen embrittled by sunlight and cold weather.

Ideal for structural protrusions; many techniques employed to flash complicated shapes such as H-beams, I-beams and C-channels can be labour intensive and lacking in consistent quality, performance and looks. Thaler Split Flashings are quality controlled at the factory, sized to accommodate precise web thicknesses, while sleeves employ a simple, applicator-friendly, snap together "lock-fast" installation procedure.

Utilizes proven concept; Thaler Split Flashings provide the best flashing detail at roof penetrations which follows the general rule of attaching the base flashing (sleeve) to the structural deck and counter flashing (cap) to the penetrating element.

Aesthetically pleasing; arguably the best looking split flashing available on the market today. Unique installation method means clean assembly without messy caulking seals, soldered joints or adhesives.

Re-Usable; providing split flashings are carefully twisted off, they can be used again for re-roofing projects.

EPDM Triple Pressure Grommet Seal; EPDM "memory" in the seal provides constant pressure to outside of protrusion to prevent leaks. See Thaler EPDM Flashing Seals literature.

CSA Approved; all Thaler flashings conform to CSA B272-93 - Prefabricated Self-Sealing Roof Vent Flashings.

Treated deck flange; can be PVC coated for proper welding of PVC membrane or bituminous painted for BUR or ModBit membrane.

20 year Warranty; guaranteed against leaks and defects in materials and/or manufacture when installed in accordance with Thaler "Installation Instructions".

Maintenance-Free; never needs caulking (any caulking at any time will invalidate 20 year warranty.

Written "Installation Instructions"; provided with every Thaler product.

J-0

CHECK THECOMPETITION

THALER VALUEADDED FEATURES

ROOF SPECIALTIESSPLIT FLASHINGS

Stamp
Page 4: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

STEEL DECK CONCRETE DECK

EPDM TRIPLE PRESSURE GROMMET SEAL

1/8" (3 mm) STAINLESS STEEL NUTS AND BOLTS

26 ga. TYPE 304STAINLESS STEEL CAP

26 ga. TYPE 304 STAINLESSSTEEL SLEEVE

5" (127 mm)

FRO

M 9

" TO

48"

HIG

H (2

29 m

m T

O 1

220

mm

) IN

AN

Y IN

CR

EMEN

T

ONE THIRD OF SLEEVE SIZE TO MAXIMUM OF 12" (305 mm)

3 PLY FELT FLASHING OVER FLANGE 4" (102 mm), 6" (152 mm) AND 8" (203 mm) ONTO ROOF

4" (102 mm) TO 120" (3048 mm) DIA.

IN ANY INCREMENT

IS STANDARD

TOP VIEW OF CAP

STAINLESS STEEL CLIPS,ARE USED TO SNAP OR LOCK FRICTION FITTED FLASHING SECTION TOGETHER

EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT (BUR)

1" (2

5 m

m)

ROOF SPECIALTIESSPJ-1 ROUNDSPLIT FLASHINGS

DESCRIPTION:Thaler SPJ-1 Round Split Flashings consist of a split stainless steel flashing sleeve with integral deck flange and split coolie-hat cap fitted with an EPDM triple pressure grommet seal. Continuous EPDM seals are also located at the split junctures of the sleeve and deck flange. Available in stainless steel only. Clips are used to snap or lock the friction-fit flashing sections together.

DIAMETER:3" to 120" (76 mm to 3048 mm) in any increment. Note: Flashings are installed in two split sections for up to 48" (1220 mm) dia; three sections for 48" to 72" (1220 mm to 1830 mm) dia; four sections for over 72" (1830 mm) dia.

HEIGHT:9" to 48" (229 mm to 1220 mm) in any increment.

PROMINENT FEATURES:Custom sizing is standard. Never needs caulking (see Thaler EPDM Flashing Seals literature). More economical than SPJ-2 Round Split Flashing (Vented Cap).

OPTIONS:PVC coated deck flange for PVC roof membrane. Bituminous painted deck flange for BUR and ModBit roof membrane. See SPJ- 2 for vented cap (prevents condensation build-up on inside of sleeve).

RECOMMENDED USE:Suitable for round plastic, steel, stainless, copper or cast iron pipes, stacks or other round roof projections where flashing sleeve can only be fitted around the projection rather than over it. Example uses include hydro generator stacks, oil refinery process piping, railings, and other retrofit applications.

APPROVALS:CSA Approved to CSA B272-93 (Prefabricated Self-Sealing Roof Vent Flashings). Note: In addition to the CSA tests, Thaler in-house testing was performed with the EPDM Triple Pressure Grommet Seal submerged in 8" (203 mm) of water for 3 months with no leakage.

WARRANTY:20 year warranty against leaks and defects in materials and/or manufacture when installed in accordance with Thaler "Installation Instructions". Warranty not valid where EPDM seals are subjected to unusually harsh corrosive environments e.g. pulp mills, mining facilities and similar applications.

MAINTENANCE:No maintenance required (maintenance free).

SPECIFICATION (SHORT FORM):Round split flashings: Thaler SPJ-1 Round, Split Flashing [12" (305 mm) high] x [8" (203 mm) dia.] [of sizes as noted on drawings] .018" (26 ga.) sleeve with gauge of cap to suit, Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split cap with overlapped and s.s. bolted closure design; manufactured by Thaler Metal Industries, 1-800-387-7217 (Mississauga, Ontario, Canada) or 1-800-576-1200 (New Braunfels, TX), installed as per manufacturer's written instructions. Provide 20 year warranty against leaks and defects in materials and/or manufacture.

INSTALLATION:"Installation Instructions" are provided with every Thaler product. Essentially, Thaler split flashings are installed by aligning the flashing sections (2, 3, or 4 sections, depending on diameter), applying silicone lubricant to EPDM seals, temporarily snapping the sections together using one or more Crawford ratchet type tightening straps (by others), and as follows:

BUR: Set deck flange in layer of plastic cement and flash in with 3 overlapping layers of felt flashing.

ModBit: orch membrane until bitumen is fluid and set flange into fluid. Flash in flange with two overlapping layers of ModBit and seal with asphalt sealer.

Single Ply: Set deck flange in layer of membrane adhesive and extend single ply up sleeve as per single ply manufacturer's recommenda-tions and clamp membrane to flashing. Note: for PVC membrane, specify PVC coated flashing by adding suffix P to end of model number, e.g. SJP-1-P; weld roofing to deck flange using PVC torch

Precautions: If coating deck flange with bituminous paint on site, allow 24 hours for drying before applying roof membrane.

Coolie-Ht Cap: Twist cap open and fit around pipe or protrusion and connect the lap joint by re-installing the stainless steel bolt.

Ordering: Available throughout North SPJ-1 ROUND SPLIT FLASHING America. Contact Thaler forcurrent cost information. Most products readily available from stock.

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

SPJ-1 ROUND SPLIT FLASHING PATENTED

Stamp
Page 5: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

1" (25 mm)

6.5" (165 mm)

ISOMETRIC VIEW

TOP VIEW

FRONT VIEW

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Page 6: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

FRO

M 1

2" T

O 4

8"

(305

mm

TO

122

0 m

m)

IN A

NY

INC

RE

ME

NT

EPDM TRIPLE PRESSURE GROMMET SEAL

1/8" (3 mm) S.S. SCREW

PERFORATED FOR 2" (51 mm) DEPTH

0.048" (18 ga.) TYPE 304 STAINLESS STEEL CAP UP TO 12" (305 mm) AND 0.018" (26 ga.) FOR LARGER SIZES

0.018" (26 ga.) TYPE 304STAINLESS STEEL SLEEVE

PATENTED

5" (127 mm)

4" (102 mm) TO 120" (3048 mm)

IN ANY INCREMENT

IS STANDARD

3 PLY FELT FLASHING OVER FLANGE AN 4" (102 mm) 6" (152 mm) AND 8" (203 mm) ONTO ROOF

EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT

STAINLESS STEEL CLIPSARE USED TO SNAP OR LOCK THE FRICTION-FIT FLASHINGS SECTIONS TOGETHER

TOP VIEW OF CAP

STEEL DECK CONCRETE DECK

ROOF SPECIALTIESSPJ-2 ROUNDSPLIT FLASHINGS (Vented Cap)

DESCRIPTION:Thaler SPJ-2 Round Split Flashings consist of a split stainless steel flashing sleeve with integral deck flange and vented cap fitted with an EPDM triple pressure grommet seal. Continuous EPDM seals are also located at the split junctures of the sleeve and deck flange. Available in stainless steel only. Clips are used to snap or lock the friction-fit flashing sections together.

DIAMETER:4" to 120" (102 mm to 3048 mm) in any increment. Note: Flashings are installed in two sections for up to 48" (1220 mm) dia; three sections for 48" to 72" (1220 mm to 1830 mm) dia; four sections for over 72" (1830 mm) dia.

HEIGHT:9" to 48" (229 mm to 1220 mm) in any increment.

PROMINENT FEATURES:Prevents condensation build-up on inside of sleeve. Custom sizing is standard. Never needs caulking (see Thaler EPDM Flashing Seals literature).

OPTIONS:PVC coated deck flange for PVC roof membrane. Bituminous painted deck flange for BUR and ModBit roof membrane. See SPJ-1 Coolie-Hat Cap for more economical flashing.

RECOMMENDED USE:Suitable for plastic, steel, stainless, copper or cast iron pipes, stacks or other round roof projections where flashing sleeve can only be fitted around vent stack rather than over the stack. Example uses include hydro generator stacks, oil refinery process piping, railings, and other retrofit applications.

APPROVALS:CSA Approved to CSA B272-93 (Prefabricated Self-Sealing Roof Vent Flashings). Note: In addition to the CSA tests, Thaler in-house testing was performed with the EPDM Triple Pressure Grommet Seal submerged in 8" (203 mm) of water for 3 months with no leakage.

WARRANTY:20 year warranty against leaks and defects in materials and/or manufacture when installed in accordance with Thaler "Installation Instructions". Warranty not valid where EPDM seals are subjected to unusually harsh corrosive environments e.g. pulp mills, mining facilities and similar applications.

MAINTENANCE:No maintenance required (maintenance free).

SPECIFICATION (SHORT FORM):Round split flashings: Thaler SPJ-2 Round, Vented Cap Split Flashing [12" (305 mm) high] x [8" (203 mm) dia.] [of sizes as noted on drawings] .018" (26 ga.) sleeve with gauge of cap to suit, Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split vented cap with overlapped and s.s. bolted closure design; manufactured by Thaler Metal Industries, 1-800-387-7217 (Mississauga, Ontario, Canada) or 1-800-576-1200 (New Braunfels, TX), installed as per manufacturer's written instructions. Provide 20 year warranty against leaks, condensation and defects in materials and/or manufacture.

INSTALLATION:"Installation Instructions" are provided with every Thaler product. Essentially, Thaler split flashings are installed by aligning the flashing sections (2, 3, or 4 sections, depending on diameter), applying silicone lubricant to EPDM seals, snapping the sections together using safe grip plypliers.

BUR: Set deck flange in layer of plastic cement and flash in with 3 overlapping layers of felt flashing.

ModBit: Torch membrane until bitumen is fluid and set flange into fluid. Flash in flange with two overlapping layers of ModBit and seal with asphalt sealer.

Single Ply: Set deck flange in layer of membrane adhesive and extend single ply up sleeve as per single ply manufacturer's recommenda-tions and clamp membrane to flashing. Note: for PVC membrane, specify PVC coated flashing by adding suffix P to end of model number, e.g. SJP-2-P; weld roofing to deck flange using PVC torch.

Vented Cap: Fit sections around pipe or protrusion and connect the lap joints by re-installing the stainless steel bolts.

Ordering: Available throughout North America. Contact Thaler for lists of distributors and current cost information. Most products readily available from stock.

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

SPJ-2 ROUND SPLIT FLASHING (Vented Cap) PATENTED

Stamp
Page 7: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

Stainless Steel CapEPDM Triple Pressure

Grommet Seal

Stainless Steel Clip

Stainless Steel Sleeve

Stainless Steel Screw

EPDM Seal

1" (25 mm)

6.5" (165 mm)

FRONT VIEW

EXPLODED VIEW

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Page 8: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

0.018" (26 ga.) TYPE 304STAINLESS STEEL CAP

0.018" (26 ga.) TYPE 304STAINLESS STEEL SLEEVE

S.S INSTALLATION CLAMPING CLIPS SPOT WELDED TO SLEEVE ON TWO SIDES (3 OR 4 CLIPS DEPENDING ON HEIGHT)

5" (127 mm)

EPDM TRIPLE PRESSURE GROMMET SEAL

PATENTED

1/8" (3 mm) STAINLESS STEEL SCREW

12" (

305

mm

) OR

18"

(457

mm

)

1" (2

5 m

m)

3 PLY FELT FLASHING OVER FLANGE 4" (102 mm) 6" (152 mm) AND 8" (203 mm) ONTO ROOF

EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT

TOP VIEW OF CAP

KCED ETERCNOCKCED LEETS

ROOF SPECIALTIESSPJ-3 SQUARESPLIT FLASHINGS

DESCRIPTION:Thaler SPJ-3 Square Split Flashings consist of a two-piece split stainless steel flashing sleeve with integral deck flange and four-piece split coolie-hat cap fitted with an EPDM triple pressure grommet seal. Continuous EPDM seals are also located at the split junctures of the sleeve and deck flange. Available in stainless steel only. Clips are used to snap or lock the friction-fit flashing sections together.

SIZE:Fits up to 12" (305 mm) square protrusion in any increment.

HEIGHT:12" (305 mm) and 18" (457 mm) is standard. Consult Thaler for other heights.

PROMINENT FEATURES:Never needs caulking (see Thaler EPDM Flashing Seals literature). More economical than SPJ-4 Square Split Flashing (Vented Cap).

OPTIONS:PVC coated deck flange for PVC roof membrane. Bituminous painted deck flange for BUR and ModBit roof membrane. See SPJ- 4 for vented cap (prevents condensation build-up on inside of sleeve).

RECOMMENDED USE:Suitable for all types of square roof projections where flashing sleeve can only be fitted around the projection rather than over the projection. Example uses include square columns, railings, supports, and other retrofit applications.

APPROVALS:CSA Approved to CSA B272-93 (Prefabricated Self-Sealing Roof Vent Flashings). Note: In addition to the CSA tests, Thaler in-house testing was performed with the EPDM Triple Pressure Grommet Seal submerged in 8" (203 mm) of water for 3 months with no leakage.

WARRANTY:20 year warranty against leaks and defects in materials and/or manufacture when installed in accordance with Thaler "Installation Instructions". Warranty not valid where EPDM seals are subjected to unusually harsh corrosive environments e.g. pulp mills, mining facilities and similar applications.

MAINTENANCE:No maintenance required (maintenance free).

SPECIFICATION (SHORT FORM):Square split flashings: Thaler SPJ-3 Square, Cap Split Flashing [12" (305 mm) high] [18" (457 mm) high] x [8" (203 mm) square] [of sizes as noted on drawings] .018" (26 ga.) Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split cap with overlapped and s.s. bolted closure design; manufactured by Thaler Metal Industries, 1-800-387-7217(Mississ- auga, Ontario, Canada) or 1-800-576-1200 (New Braunfels, TX), installed as per manufacturer's written instructions. Provide 20 year warranty against leaks and defects in materials and/or manufacture.

INSTALLATION:"Installation Instructions" are provided with every Thaler product. Essentially, Thaler split flashings are installed by aligning the two flashing sections, applying silicone lubricant to EPDM seals, snapping the sections together using pliers at clip locations, and as follows:

BUR: Set deck flange in layer of plastic cement and flash in with 3 overlapping layers of felt flashing.

ModBit: Torch membrane until bitumen is fluid and set flange into fluid. Flash in flange with two overlapping layers of ModBit and seal with asphalt sealer.

Single Ply: Set deck flange in layer of membrane adhesive and extend single ply up sleeve as per single ply manufacturer's recommenda-tions and clamp membrane to flashing. Note: for PVC membrane, specify PVC coated flashing by adding suffix P to end of model number, e.g. SJP-3-P; weld roofing to deck flange using PVC torch.

Coolio-Hat Cap: Twist cap open and fit around pipe or protrusion and connect the lap joint by re-installing the stainless steel bolt.

Ordering: Available throughout North America. Contact Thaler for lists of distributors and current cost information. Most products readily available from stock.

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

SPJ-3 SQUARE SPLIT FLASHING PATENTED

Stamp
Page 9: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

12" (

305

mm

) OR

18"

(457

mm

).C

ON

SULT

TH

ALE

R F

OR

OTH

ER

HEI

GH

TSEPDM TRIPLE PRESSURE GROMMET SEAL

1/8" (3 mm) S.S. SCREW

PERFORATED FOR 2" (51 mm) DEPTH

.048" (18 ga.) TYPE 304 STAINLESS STEEL CAP UP TO 12" (305 mm) AND .018" (26 ga.) FOR LARGER SIZES

.018" (26 ga.) TYPE 304 STAINLESS STEEL SLEEVE

3 PLY FELT FLASHING OVER FLANGE AND 4" (102 mm) 6" (152 mm) 8" (203 mm) ONTO ROOF

PATENTED

5" (127 mm)

3" (7

5 m

m)

UP TO 12" (305 mm)

SQ. STANDARD

EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT (BUR)

STAINLESS STEEL CLIPSARE USED TO SNAP OR LOCK FRICTION-FIT FLASHING SECTIONS TOGETHER

1" (2

5 m

m)

STEEL DECK CONCRETE DECK

ROOF SPECIALTIESSPJ-4 SQUARESPLIT FLASHINGS (Vented Cap)

DESCRIPTION:Thaler SPJ-4 Square Split Flashings consist of a split stainless steel flashing sleeve with integral deck flange and contoured vented cap fitted with an EPDM triple pressure grommet seal. Continuous EPDM seals are also located at the split junctures of the sleeve and deck flange. Available in stainless steel only. Clips are used to snap or lock the friction-fit flashing sections together.

SIZE:Fits up to 12" (305 mm) square protrusion in any increment.

HEIGHT:12" (305 mm) and 18" (457 mm) is standard. Consult Thaler for other heights.

PROMINENT FEATURES:Prevents condensation build-up on inside of sleeve. Never needs caulking (see Thaler EPDM Flashing Seals literature).

OPTIONS:PVC coated deck flange for PVC roof membrane. Bituminous painted deck flange for BUR and ModBit roof membrane. See SPJ-3 Coolie-Hat Cap for more economical flashing.

RECOMMENDED USE:Suitable for all types of square roof projections where flashing sleeve can only be fitted around the projection rather than over the projection. Example uses include square columns, railings, supports, and other retrofit applications.

APPROVALS:CSA Approved to CSA B272-93 (Prefabricated Self-Sealing Roof Vent Flashings). Note: In addition to the CSA tests, Thaler in-house testing was performed with the EPDM Triple Pressure Grommet Seal submerged in 8" (203 mm) of water for 3 months with no leakage.

WARRANTY:20 year warranty against leaks and defects in materials and/or manufacture when installed in accordance with Thaler "Installation Instructions". Warranty not valid where EPDM seals are subjected to unusually harsh corrosive environments e.g. pulp mills, mining facilities and similar applications.

MAINTENANCE:No maintenance required (maintenance free).

SPECIFICATION (SHORT FORM):Square split flashings: Thaler SPJ-4 Square, Vented Cap Split Flashing [12" (305 mm) high] [18" (457 mm) high] x [8" (203 mm) square] [of sizes as noted on drawings] .018" (26 ga.) Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split vented cap with overlapped and s.s. bolted closure design; manufactured by Thaler Metal Industries, 1-800-387-7217 (Mississauga, Ontario, Canada) or 1-800-576-1200 (New Braunfels, TX), installed as per manufacturer's written instructions. Provide 20 year warranty against leaks, condensation and defects in materials and/or manufacture.

INSTALLATION:"Installation Instructions" are provided with every Thaler product. Essentially, Thaler split flashings are installed by aligning the two flashing sections, applying silicone lubricant to EPDM seals, snapping the sections together using pliers at clip locations, and as follows:

BUR: Set deck flange in layer of plastic cement and flash in with 3 overlapping layers of felt flashing.

ModBit: Torch membrane until bitumen is fluid and set flange into fluid. Flash in flange with two overlapping layers of ModBit and seal with asphalt sealer.

Single Ply: Set deck flange in layer of membrane adhesive and extend single ply up sleeve as per single ply manufacturer's recommenda-tions and clamp membrane to flashing. Note: for PVC membrane, specify PVC coated flashing by adding suffix P to end of model number, e.g. SJP-4-P; weld roofing to deck flange using PVC torch.

Vented Cap: Fit sections around pipe or protrusion and connect the lap joints by re-installing the stainless steel bolts.

Ordering: Available throughout North America. Contact Thaler for lists of distributors and current cost information. Most products readily available from stock.

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

SPJ-4 SQUARE SPLIT FLASHING (Vented Cap)PATENTED

Stamp
Page 10: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

1.0

6.5

Stainless Steel Cap

Stainless Steel Sleeve

EPDM Seal

EPDM Triple Pressure Grommet Seal

Stainless Steel Clips

TOP VIEW

FRONT VIEW

EXPLODED VIEW

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Page 11: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

ROOF SPECIALTIESSPLIT FLASHINGSSPECIFICATION

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

PART 1: GENERAL

1.01 SECTION INCLUDES

A. Supply and installation of roof accessories, including: 1. Preformed metal flashings

1.02 RELATED SECTIONS

A. Section 06100 - Rough Carpentry B. Section 07500 - Membrane Roofing C. Section 07900 - Joint Sealers D. Section 15800 - Air Distribution

1.03 REFERENCES

[A. CSA B272-93 - Prefabricated Self-Sealing Roof Vent Flashings] [B. CRCA (Canadian Roofing Contractor's Association)] [C. NRCA (National Roofing Contractor's Association)] [D. SPRI (Single Ply Roofing Institute)] 1.04 SUBMITTALS

A. Manufacturer’s descriptive literature for each product, including section or other type details. B. Manufacturer’s written installation instructions.

C. Shop drawings and samples, when required, in accordance with Section [01300].

1.05 QUALITY ASSURANCE

A. Roof accessories manufactures to have minimum 5 years documented experience in the design and fabrication of roofing specialities and accessories.

1.06 SPECIAL WARRANTY

A. Warrant products installed under this section of work to be free of defects in materials and/or manufacture [and condensation] for a period of 20 years when installed in accordance with the manufacturer's written instructions.

Note: This mechanical and electrical roof support specification, with minor editing, has been written as a separate section of work. Alternatively, the appropriate clauses may be incorporated as part of a roofing specification.

J-5

Stamp
Page 12: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

ROOF SPECIALTIESSPLIT FLASHINGSSPECIFICATION

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

PART 2: PRODUCTS

2.01 MANUFACTURER

A. Provide products as manufactured by Thaler Metal Industries, 1-800-387-7217 (Mississauga, Ontario, Canada) or 1-800-576-1200 (Buffalo, NY) or provide equal products by another manufacturer approved in advance by the [Architect], based upon: 1. 20 year warranty against defects in materials and/or manufacture, as applicable; 2. compliance with CSA B272-93 (Prefabricated Self-Sealing Roof Vent Flashings) 3. air barrier design using EPDM seals only; 4. maintenance free design; 5. materials and sizes options, and thickness; 6. injection molded urethane insulation to CGSB-51-GP 46MP and ASTM C1029-90, as applicable; 7. treated deck flange, as applicable; 8. written installation instructions.

2.02 MANUFACTURED UNITS

SPJ-1 Round Split Flashing A. Thaler SPJ-1 Round, Split Flashing [12" (305 mm) high] x [8" (203 mm) dia.] [of sizes as noted on drawings] .018" (26 ga.) sleeve with gauge of cap to suit, Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split cap with overlapped and s.s. bolted closure design.

SPJ-2 Round Split Flashing (Vented Cap) B. SPJ-2 Round, Vented Cap Split Flashing [12" (305 mm) high] x [8" (203 mm) dia.] [of sizes as noted on drawings] .018" (26 ga.) sleeve with gauge of cap to suit Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck lange; [PVC coated deck flange] [bituminous painted deck flange]; matching split vented cap with overlapped and s.s. bolted closure design.

SPJ-3 Square Split Flashing C. Thaler SPJ-3 Square, Split Flashing [12" (305 mm) high] [18" (457 mm) high] x [8" (203 mm) square] [of sizes as noted on drawings] .018" (26 ga.) sleeve with gauge of cap to suit, Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split cap with overlapped and s.s. bolted closure design. SPJ-4 Square Split Flashing (Vented Cap) D. Thaler SPJ-4 Square, Vented Cap Split Flashing [12" (305 mm) high] [18" (457 mm) high] x [8" (203 mm) square][of sizes as noted on drawings] .018" (26 ga.) sleeve with gauge of cap to suit, Type 304 stainless steel; to CSA B272-93; with EPDM triple pressure grommet seal around cap and continuous EPDM seals at split junctures of sleeve and deck flange; [PVC coated deck flange] [bituminous painted deck flange]; matching split vented cap with overlapped and s.s. bolted closure design.

PART 3: EXECUTION

3.01 EXAMINATION

A. Report to the Contractor in writing, defects of work prepared by other trades and other unsatisfactory site conditions. Verify site dimensions. Commencement of work will imply acceptance of prepared work.

J-6

Page 13: SECTION J SPLIT FLASHINGS - Prefabricated Roof Flashings ... › wp-content › uploads › Section_J_Split_Flashings.pdfroof embed deck flange in layer of plastic cement stainless

ROOF SPECIALTIESSPLIT FLASHINGSSPECIFICATION

CANADA: 1.800.387.7217 U.S.: 1.800.576.1200 WEB: www.thalermetal.com EMAIL: [email protected]

Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.

3.02 INSTALLATION

A. Install relief vents in accordance with manufacturer’s printed instructions. BUR B. Set flashing deck flange in layer of plastic cement and flash in with 3 overlapping layers of felt flashing.

Modified Bitumen C. Torch membrane until bitumen is fluid and set flange into fluid. Flash in flange with two overlapping layers of ModBit and seal with asphalt sealer.

Single Ply D. Set deck flange in layer of membrane adhesive and extend single ply up sleeve to highest elevation possible and clamp membrane to Flashing.

Note: For PVC membrane, specify PVC coated flashing by adding suffix P to end of Thaler model number, e.g. SJ-24-P; weld roofing to deck flange using PVC torch.

PVC Single Ply E. Set deck flange in layer of membrane adhesive and extend single ply up sleeve to highest elevation possible and clamp membrane to flashing. Weld roofing to deck flange using PVC torch.

Shingle Roof F. Set deck flange in layer of plastic cement, ensuring that flange is placed over shingles on downslope side of flashing and under shingles on upslope side.

3.03 FIELD QUALITY CONTROL

A. Comply with the requirements of Section [01400 - Quality Control]. 3.04 ADJUSTING

A. Verify that all manufactured units have been installed in accordance with specifications and details, and will function as intended. Adjust any items where necessary to ensure proper operation.

3.05 CLEANING

A. Clean manufactured units using materials and methods approved by manufacturer. Do not use cleanersor techniques which could impair performance of the roofing system.

End Of Section

J-7