6
IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 6 seem 4 LED mud-in drywall FSM4L -XF FOCAL POINT Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL. CONFIGURATIONS ARE RUN SPECIFIC, PLEASE CONSULT FACTORY DRAWINGS BEFORE BEGINNING INSTALLATION. DRYWALL THICKNESS ORIENTATION GUIDE POINT POSITION 3 /8" 1 X F 1 /2" 1 X E 5 /8" 1 X D 3 /4" 1 X C 7 /8" 1 X B 1" 1 X A 1 1 /8" 1 Y G 1 1 /4" 2 Y F 1 3 /8" 2 Y E 1 1 /2" 2 Y D 1 5 /8" 2 Y C 1 3 /4" 2 Y B 1 7 /8" 2 Y A 2" 2 X E 2 1 /8" 2 X D A X orientation 1 orientation 2 Y B C D E F G H X Y BACKER FLANGE PLACEMENT GUIDE A X orientation 1 B C D E F G H 5/85 /8" DRYWALL BACKER FLANGE (MAY BE PRE-INSTALLED OR SHIPPED LOOSE) MUD FLANGE (SHIPPED LOOSE) KEY POWER OFF POWER ON ATTENTION A X orientation 1 B C D E F G H 1/21 /2" DRYWALL U - INDIVIDUAL S - START OF RUN I - INTERMEDIATE CORNER UNIT HOUSING SPACER (11699) BACKER FLANGE (72001) (8-32X 3/8” WASHER HEX HEAD SCREW) MUD FLANGE (70005) (8-32 X 5/16” FLAT UNDERCUT HEAD SCREW) INCLUDED HARDWARE PARTS LISTS REFLECTOR (70008) (6-32 X 5/16 PAN-HEAD MACHINE SCREW) SHIPPED INSTALLED JOINER BRACKET (11849) JOINER BRACKET (11920) TIE WIRE BRACKET (12547) TIE-WIRE BRACKET SCREW (72010) (8-18 X 1/4 SELF TAPPING SCREW) E - END OF RUN ALIGNMENT BRACKET (REGRESS LENS) (A22092-01) ALIGNMENT PIN (REGRESS LENS) (22372) ALIGNMENT BRACKET SCREW (REGRESS LENS) (72029) POP-DOWN LENS (INDIVUDUAL HOUSINGS ONLY UP TO 8’) FLUSH LENS (A32110-01) (A32074-01) (72074) (700158) JOINER BRACKET (REGRESS LENS)

seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 6

seem 4™ LED mud-in drywall FSM4L -XF

focal point

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL.configurations are run specific, please consult factory drawings before beginning installation.

drywall thickness

orientation guide point position

3/8" 1 X F1/2" 1 X E5/8" 1 X D3/4" 1 X C7/8" 1 X B

1" 1 X A

11/8" 1 Y G

11/4" 2 Y F

13/8" 2 Y E

11/2" 2 Y D

15/8" 2 Y C

13/4" 2 Y B

17/8" 2 Y A

2" 2 X E

21/8" 2 X D

AX

orientation 1

orientation 2

Y

BCDEFGH

X

Y

backer flange placeMent guide

A

X

orientation 1

BCDEFGH

5/8”

5/8" drywall

backer flange (May be pre-installed or shipped loose)

Mud flange(shipped loose)

key

power off

power on

attention

A

X

orientation 1

BCDEFGH

1/2”

1/2" drywall

u - individual

s - start of run

i - interMediate

corner unit

housing spacer(11699)

backer flange (72001) (8-32X 3/8”

WASHER HEX HEAD SCREW)

Mud flange (70005) (8-32 X 5/16” FLAT

UNDERCUT HEAD SCREW)

included hardware

parts lists

reflector (70008)(6-32 X 5/16 pan-head

Machine screw)

shipped installed

joiner bracket (11849)joiner bracket

(11920)

tie wire bracket (12547)

tie-wire bracket screw (72010)(8-18 X 1/4 self tapping screw)

e - end of runalignMent bracket

(regress lens) (a22092-01)

alignMent pin (regress lens)

(22372)

alignMent bracket screw (regress lens)

(72029)

pop-down lens (indivudual housings

only up to 8’)

flush lens

(a32110-01)

(a32074-01)

(72074)

(700158)

joiner bracket (regress lens)

Page 2: seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 6

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

21

43 using the backer flange placeMent guide froM page 1 deterMine the

proper placeMent of the backer flange for your

drywall thickness.

5 6

individual installations skip to step 13

ceiling installation (see page 4 for wall installation)

if backer flanges were pre-installed skip to step 5

3' - 4'

2'

5' - 6'

7' - 8'

corner unit Must be asseMbled prior to ceiling installation.

AVOID ALL CONTACT WITH LED SURFACE, LEDs ARE EASILY DAMAGED!

10x2

regress lens

7 x2

8 9

do not overtighten

x2

Page 3: seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 6

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

Make electrical connections

13

11 12

151114

install spacers every 12"

attention before beginning drywall

installation consult guide on page 1 to ensure the backer flange is set at the correct

depth for the drywall.

a

b

16

drywall

181117

Make electrical connections

secure reflectors to housing (2 screws per reflector)

117 8 9

1110

x4

x4

flush /pop-down lens

Page 4: seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 6

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

wall installation

1

2"X6" fraMing reQuired on both

sides of of housing

5.625" Min

6.0" MaX

3

3' - 4'

2'

5' - 6'

7' - 8'

3 using the backer flange placeMent guide froM page 1 deterMine the

proper placeMent of the backer flange for your

drywall thickness.

if backer flanges were pre-installed skip to step 4

2019

drywall

Mud

211120

USE IMPRINT ON 0.5” POP-DOWN LENSES TO ENSURE ALL LENSES ARE INSTALLED FACING THE SAME DIRECTION

POP-DOWN lens

flush lens

Page 5: seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 5 of 6

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

1110 x4

Make electrical connections

Make electrical connections

12

14

secure reflectors to housing (2 screws per reflector)

15

attention before beginning drywall

installation consult guide on page 1 to ensure the backer flange is set at the correct

depth for the drywall.

1111

or

90˚ fitting reQuiredreMove spacers

13

install reflectors starting froM bottoM

8

7 individual installations skip to step 12 9 x4x4

4 5 116

install spacers every 12"AVOID ALL CONTACT WITH LED SURFACE,

LEDs ARE EASILY DAMAGED!

Page 6: seem 4 LED mud-in drywall - Focal Point Lights€¦ · mud-in drywall FSM4L -XF focal point Luminaires must be installed by a qualified electrician (check with local and national

Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.

IS0491 Rev. H 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 6 of 6

321

driver service

AVOID ALL CONTACT WITH LED SURFACE, LEDs ARE EASILY DAMAGED!

19

EMERGENCY

SEE BATTERY MANUFACTURER INSTRUCTIONS

eMergency MaXiMuM Mounting height: 13.00’

19

16

drywall

17 18

drywall

Mud

20

POP-DOWN lensFLUSH lens

USE IMPRINT ON 0.5” POP-DOWN LENSES TO ENSURE ALL LENSES ARE INSTALLED FACING THE SAME DIRECTION