202 | Page SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION PENDULUM SYSTEM (TFPS) Sachi Parekh 1 , Dr. M. Kumar 2 , Dr. V. R. Panchal 3 1 P. G. Student, 3 Professor, Department of Civil Engineering, Chandubhai S. Patel Institute of Technology, Charotar University of Science and Technology (CHARUSAT), Changa, Gujarat ,(India) 2 Assistant Professor, Department of Civil Engineering, Indian Institute of Technology (IIT),Gandhinagar, Gujarat ,(India) ABSTRACT In the present study, a simplified finite element model of under construction Pandit Dindayal Upadhyay cable stayed bridge on Tapi river at Surat,Gujarat,India is used for investigation. The seismic response of the bridge isolated with Friction Pendulum System (FPS) and Triple Friction Pendulum System (TFPS) are investigated under near fault ground motions.The dynamic analysis is carried out by using the SAP2000 software. The response quantity of interest are the deflection pattern of deck, tension generated in cables, base shear as well as the load transmission through pylon to the earth. In order to verify the efficiency of FPS and TFPS in the cable stayed bridge, the comparison between response of FPS and TFPS has been made. From the study, it is found that theTFPS is more effective as compared to FPS in cable stayed bridge subjected to near fault ground motions. Keywords: Cable Stayed Bridge, Friction Pendulum System, Seismic Isolation, Triple Friction Pendulum System I. INTRODUCTION Cable stayed bridge is an innovative structure which has received more attention due to their stability, optimum use of structural materials, aesthetic, low damping, high flexibility, relatively low design and maintenance cost as well as efficient structural characteristics. A cable stayed bridge is a statically indeterminate structure having a large degree of redundancy consists a system of cable provided above the deck and are connected to the tower. Whenever the vehicle passes through the deck, the vehicular live load is going to transfer in the form of tension to the cable. This tension via pylon in form of compression is going to get transfer to the earth. The cable arrangements is of different type like fan, harp, and semi fan type. As compared to conventional bridges, the analysis of these types of bridges is more complicated because of their large size and nonlinear structural behavior. From the literature survey, it is concluded that there is the lack of research is found particularly in seismic analysis of cable stayed bridge with Triple Friction Pendulum System(TFPS).The objectives of the study are,

SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

Embed Size (px)

Citation preview

Page 1: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

202 | P a g e

SEISMIC RESPONSE OF CABLE STAYED BRIDGE

ISOLATED WITH TRIPLE FRICTION PENDULUM

SYSTEM (TFPS)

Sachi Parekh

1, Dr. M. Kumar

2, Dr. V. R. Panchal

3

1 P. G. Student,

3Professor, Department of Civil Engineering,

Chandubhai S. Patel Institute of Technology, Charotar University of Science and Technology

(CHARUSAT), Changa, Gujarat ,(India)

2Assistant Professor, Department of Civil Engineering, Indian Institute of Technology

(IIT),Gandhinagar, Gujarat ,(India)

ABSTRACT

In the present study, a simplified finite element model of under construction Pandit Dindayal Upadhyay cable

stayed bridge on Tapi river at Surat,Gujarat,India is used for investigation. The seismic response of the bridge

isolated with Friction Pendulum System (FPS) and Triple Friction Pendulum System (TFPS) are investigated

under near fault ground motions.The dynamic analysis is carried out by using the SAP2000 software. The

response quantity of interest are the deflection pattern of deck, tension generated in cables, base shear as well

as the load transmission through pylon to the earth. In order to verify the efficiency of FPS and TFPS in the

cable stayed bridge, the comparison between response of FPS and TFPS has been made. From the study, it is

found that theTFPS is more effective as compared to FPS in cable stayed bridge subjected to near fault ground

motions.

Keywords: Cable Stayed Bridge, Friction Pendulum System, Seismic Isolation, Triple Friction

Pendulum System

I. INTRODUCTION

Cable stayed bridge is an innovative structure which has received more attention due to their stability, optimum

use of structural materials, aesthetic, low damping, high flexibility, relatively low design and maintenance cost

as well as efficient structural characteristics. A cable stayed bridge is a statically indeterminate structure having

a large degree of redundancy consists a system of cable provided above the deck and are connected to the tower.

Whenever the vehicle passes through the deck, the vehicular live load is going to transfer in the form of tension

to the cable. This tension via pylon in form of compression is going to get transfer to the earth. The cable

arrangements is of different type like fan, harp, and semi fan type. As compared to conventional bridges, the

analysis of these types of bridges is more complicated because of their large size and nonlinear structural

behavior. From the literature survey, it is concluded that there is the lack of research is found particularly in

seismic analysis of cable stayed bridge with Triple Friction Pendulum System(TFPS).The objectives of the

study are,

Page 2: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

203 | P a g e

(i)To investigate the behavior of TFPS in cable stayed bridge under the near fault ground motions and

(ii) To compare the response of cable stayed bridge isolated with FPS and TFPS in order to verify the efficiency

of TFPS.

II. SALIENT FEATURES OF CABLE STAYED BRIDGE

The example bridge studied here is Pandit Dindayal Upadhyay cable stayed bridge under construction on Tapi

river at Surat, Gujarat, India. The total length of the bridge is 300 m with 150 m central span.The bridge pylon is

of 35m height above the deck level and 12 m below deck level as shown in Fig.1.The schematic diagram of plan

of cable stayed bridge is as shown in Fig.2.The diaphragm of deck cross section is of twin box type consisting

23.5 m wide and 3 m high concrete girder as shown in Fig.3.The stay cable arrangement is a single plane system

with fan type containing 10 numbers of cable at a side.The diameter of cable and material data for the example

bridge is listed in tables

Table 1 and Table 2 MATERIAL DATA OF EXAMPLE BRIDGE

.

Figure.1Schematic diagram of cable stayed bridge

Page 3: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

204 | P a g e

Figure.2Plan view ofcable stayed bridge

Table 1CABLE DATA

Table 2 MATERIAL DATA OF EXAMPLE BRIDGE

III. FRICTION PENDULUM SYSTEM (FPS)

The Friction Pendulum bearing consists of a base-plate with an articulated slider and a spherical concave dish

and the shear force-horizontal deformation behavior is as illustrated in Fig.4.Under the horizontal motion the

spherical concave dish displaces horizontally relative to the articulated slider and base-plate as shown in Fig.5.

Sr.

No.

Cable No Diameter(m)

1 C1,C1’,C2,C2’,C4,C4’,C5,C5’,C6,C6’ 0.381

2 C3,C3’ 0.457

3 C7,C7’,C8,C8’ 0.324

4 C9,C9’,C10,C10’ 0.273

Ci = ith Outer cable Ci’ = ith Inner cable

Material E (kN/m2) Poisson’s Ratio Density (kN/m

3)

Girder Concrete (M60) 38729833 0.2 25.5

Pylon Concrete (M60) 38729833 0.2 25.5

Cable Steel 2 Х 108 0.3 76.98

Figure. 3Cross section of deck

Page 4: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

205 | P a g e

Figure.4 Schematic diagram and Hysteresis loop of FPS

(a) (b)

Figure. 5 Possible position of FPS (a) Center position (b) Maximum credible earthquake

IV. TRIPLE FRICTION PENDULUM SYSTEM (TFPS)

The Triple Pendulum bearing is modern sliding system containing better seismic performance with three slider

as the rigid slider, articulated slider and plate as shown in Fig.6. As the ground motions become stronger, the

bearing displacements increase as shown in Fig.7.

Figure. 6 Schematic diagram and Hysteresis loop of TFPS

(a) (b) (c) (d)

Figure. 7 Possible position of TFPS (a) Center position (b) Inner pendulum motion service level earthquake

(c)Lower pendulum motion design basis earthquake (d) Upper pendulum motion maximum credible earthquake

FPS maintains the constant friction, lateral stiffness, and dynamic period for all levels of earthquake motion and

displacements where as in TFPS, the three pendulum mechanisms are sequentially activated as the earthquake

Page 5: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

206 | P a g e

motions become stronger. The small displacement, high frequency ground motions are absorbed by the low

friction and short period inner pendulum. For the stronger design level earthquakes, both the bearing friction and

period increase, resulting in lower bearing displacements and lower structure base shears. For the strongest

Maximum Credible Earthquakes, both the bearing friction and lateral stiffness increase, reducing the bearing

displacement.

V. FINITE ELEMENT MODEL IN SAP 2000

The finite element model has been generated and analyzed using SAP 2000 software by considering all

necessary dimensions and property as mentioned above. The diaphragm is provided at 3.5 m center to center.

Each cable is treated as a plane truss element and the bridge dead load is applied, which is its own weight. The

boundary condition for the pier as well as abutment are assumed to be fix.The isolator is placed in such a way

that it connects deck and pylon.The property assigned for FPS and TFPS is illustrated from [2]and[4]

respectively and assigned as mentioned in

Table 3.The Vertical stiffness for both system must be higher than stiffness assigned in lateral direction.

Table 3LATERAL DIRECTIONAL PROPERTIES FOR FPS AND TFPS

Parameters FPS

TFPS

Outer Top Outer

Bottom Inner Top

Inner

Bottom

Effective Stiffness (kN/m) 6447.901 1694.3523 1694.3523 1694.3523 1694.3523

Effective Damping 0 0 0 0 0

Elastic Stiffness (kN/m) 1001000 525380.6 525380.6 525380.6 525380.6

Friction Coefficient, Slow 0.05 0.065 0.035 0.015 0.015

Friction Coefficient, Fast 0.05 0.13 0.07 0.03 0.03

Rate Parameter (sec/m) 1 100 100 100 100

Net Pendulum Radius (m) 1.5531 2.0955 2.0955 0.1905 0.1905

Stop Distance (m) 0 0.4572 0.4572 0.0508 0.0508

VI. NEAR-FAULT GROUND MOTIONS USED IN STUDY

Page 6: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

207 | P a g e

To evaluate the seismic response of cable stayed bridge, threenear fault ground motions such as Kobe

(1995),Loma Prieta(1989) and Northridge (1994)are used for analysisof cable stayed bridge.The acceleration,

velocity and displacement time history of all the ground motions used in study along with their pseudo-

acceleration spectra for

5 %damping is shown in Fig. 8 to 11. TheN-S component of earthquake is applied in longitudinal direction of

the bridge. Table 4 shows the magnitude,Peak ground acceleration(PGA),Pear ground velocity(PGV) and Peak

ground displacement(PGD) for near fault ground motion.

Table 4 GROUND MOTION DATA

Earthquake Magnitude PGA (g) PGV (m/sec) PGD (m)

Kobe,1995 6.9 1.09106 1.60347 0.40039

Loma Prieta,1989 7 0.71785 1.72877 0.65108

Northridge,1994 6.7 0.89018 1.74531 0.39107

-1.0

-0.5

0.0

0.5

1.0

-1.5

0.0

1.5

0 10 20 30 40 50

-0.4

-0.2

0.0

0.2

0.4

Acc

eler

atio

n (

g)

KOBE,1995 (Longitudinal)

Vel

oci

ty (

m/s

ec)

Dis

pla

cem

ent

(m)

Time (sec)

Figure.8 Acceleration,Velocity and Displacement time histories of NS component of Kobe Earthquake,1995

-0.8

-0.4

0.0

0.4

0.8

-1

0

1

2

0 5 10 15 20 25-0.8

-0.6

-0.4

-0.20.0

0.2

0.4

0.6

Acc

eler

atio

n (

g)

LOMA PRIETA,1989 (Longitudinal)

Vel

ocit

y (

m/s

ec)

Dis

pla

cem

ent

(m)

Time (sec)

Figure.9Acceleration, Velocity and Displacement time histories of NS component of Loma prieta

Earthquake,1989

Page 7: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

208 | P a g e

-0.8

-0.4

0.0

0.4

0.8

-1.0

-0.5

0.0

0.5

1.0

1.5

2.0

0 2 4 6 8 10 12 14-0.3-0.2-0.10.00.10.20.30.4

Acc

eler

atio

n (

g)

NORTHRIDGE,1994 (Longitudinal)

Vel

ocit

y (

m/s

ec)

Dis

pla

cem

ent

(m)

Time (sec)

Figure.10Acceleration, Velocity and Displacement time histories of NS component of Northridge

Earthquake,1994

0 1 2 3 4

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

Pse

udo-A

ccel

erati

on (

g)

Time (sec)

Kobe,1995

Loma Prieta,1995

Northridge,1994

Figure. 11Pseudo-Accelerationspectra of NS component of near fault ground motion for 5% damping

VII. RESULTS

Page 8: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

209 | P a g e

Figure. 12Comparison of Time period of uncontrolled and controlled bridge

0 5 10 15 20 25-300000

-200000

-100000

0

100000

200000

Base

Shea

r (KN

)

Time (sec)

Non-isolated

FPS

TFPS

LOMA PRIETA,1989

Page 9: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

210 | P a g e

0 10 20 30 40 50 60

-200000

-100000

0

100000

200000

300000

Base

Shea

r (kN

)

Time (sec)

Non-isolated

FPS

TFPS

KOBE,1995

0 2 4 6 8 10 12 14-400000

-300000

-200000

-100000

0

100000

200000

300000

Base

Shea

r (KN

)

Time (sec)

Non-isolated

FPS

TFPS

NORTHRIDGE,1994

Figure.13 Comparison of Base Shear for Non-isolated and Isolated Bridge

0 10 20 30 40 50 60

-0.6-0.4-0.20.00.20.40.6

0 5 10 15 20 25-1.2

-0.8

-0.4

0.0

0.4

0.8

NORTHRIDGE,1994(FPS)

NORTHRIDGE,1994(TFPS)

0 2 4 6 8 10 12 14-0.6

-0.4

-0.2

0.0

0.2

0.4

Bea

ring

Dis

palc

emen

t (m

)

KOBE,1995(FPS)

KOBE,1995(TFPS)

LOMA PRIETA,1989(FPS)

LOMA PRIETA,1989(TFPS)

Time (sec)

Figure. 14Response of bearing displacement for FPS and TFPS

Page 10: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

211 | P a g e

-0.20 -0.15 -0.10 -0.05 0.00 0.05 0.10 0.15 0.20

-4000

-2000

0

2000

4000

-0.20 -0.15 -0.10 -0.05 0.00 0.05 0.10 0.15 0.20-6000

-4000

-2000

0

2000

4000

6000

-0.15 -0.10 -0.05 0.00 0.05 0.10 0.15

-4000

-2000

0

2000

4000

Bas

e Sh

ear

(kN

)

KOBE,1995 (FPS)

LOMA PRIETA,1989 (FPS)

Displacement (m)

NORTHRIDGE,1994 (FPS)

-0.6 -0.4 -0.2 0.0 0.2 0.4 0.6-8000-6000-4000-2000

0200040006000

-1.2 -1.0 -0.8 -0.6 -0.4 -0.2 0.0 0.2 0.4 0.6 0.8-15000

-10000

-5000

0

5000

10000

-0.6 -0.4 -0.2 0.0 0.2 0.4

-6000-4000-2000

0200040006000

Kobe,1995(TFPS)

LOMA PRIETA,1989 (TFPS)

NORTHRIDGE,1994 (TFPS)

Bas

e Sh

ear (

kN)

Displacement (m)

Figure.15Obtained force deformation relation loop for FPS and TFPS for ground motion

Page 11: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

212 | P a g e

Figure.16Comparison of base shear for Non-isolated and Isolated Bridge with FPS and TFPS

Figure.17 Comparison of deck acceleration for Non-isolated and Isolated with FPS and TFPS

Figure.18% Reduction in base shear for Non-isolated and Isolated with FPS and TFPS

Page 12: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

213 | P a g e

Figure.19 % Reduction in Deck acceleration for Non-isolated and Isolated with FPS and TFPS

Table 5COMPARISON BETWEEN THE RESPONSE OF NON-ISOLATED AND ISOLATED

Response Non-

Isolated FPS TFPS

Percent

Reduction

(%) for FPS

Percent

Reduction

(%) for

TFPS

Remark

Base Shear (kN)

257848.48 118199.19 99554.04 54.16 61.39 Kobe,1995

-211136.41 -115722.45 -120907.33 45.19 42.73

186411.96 136872.42 133436.31 26.58 28.42 Loma Prieta,1989

-179145.14 -204462.62 -257256.70 12.38 30.36

263882.90 86363.18 80292.89 67.27 69.57 Northridge,1994

-336089.83 -99509.53 -98240.71 70.39 70.77

Deck

Acceleration

(m/sec2)

11.47 5.02 4.22 56.23 63.26 Kobe,1995

-9.59 -4.54 -4.92 52.69 48.71

-11.07 9.09 5.30 41.33 41.72 Loma Prieta,1989

-8.73 5.23 -8.12 7.01 21.11

12.87 3.84 3.77 70.13 70.72 Northridge,1994

-15.90 -3.77 -3.81 76.29 76.05

Page 13: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

214 | P a g e

Table 6AXIAL FORCE IN CABLE

Outer Cable Inner Cable

Cable

No.

Non-

Isolated FPS TFPS

Cable

No.

Non-

Isolated FPS TFPS

C1 7488.812 8176.058 8304.134 C1' 7071.37 6948.316 6894.157

C2 8194.853 8560.958 8648.045 C2' 8094.969 8131.169 8153.57

C3 11265.9 11362.07 11520.38 C3' 1147.98 11569.77 11744.38

C4 9388.581 9187.739 9200.214 C4' 9730.818 9757.085 9823.484

C5 9861.465 9349.6 9307.856 C5' 10304.94 10160.26 10192.96

C6 10285.62 9352.164 9224.626 C6' 10768.62 10272.07 10223.21

C7 8971.625 7657.589 7348.115 C7' 9368.696 8434.474 8176.758

C8 9694.432 7512.305 6960.922 C8' 10057.35 8242.539 7733.096

C9 9149.695 6143.052 5286.724 C9' 10002.25 6668.564 5832.291

C10 10952.82 5924.288 4715.188 C10' 11109.77 6307.327 5107.583

VIII. CONCLUSION

The seismic response of a simplified finite element model of cable stayed bridge under construction at Tapi river

is studied under the three longitudinal component of near fault earthquake motions. From the dynamic analytical

investigation of the bridge with seismic isolation system, the following conclusion may drawn:

1. The response modal fundamental time period for isolation system is increased.

2. Reduction in base shear response and deck acceleration response of the tower is more in case of TFPS as

compare to FPS.On the other hand, increased in bearing displacement is observed in TFPS

4. Reduction of the seismic responses depends on the type of isolator as well as type of earthquake ground

motion.

5. The performance of TFPS is found to be better than that of FPS.

REFERENCES

[1]. PurnachandraSaha andR.S.Jangid, Comparative performance of isolation systems for benchmark cable

stayed bridge, International journal of applied science and engineering,Vol 6(2),111-139,2008

[2]. Christian Barun, The sliding isolation pendulum-an improved re centering bridge bearing, Steel

construction 2,Vol 3 ,2009

[3]. A.A.SSarlis and M.C.Constantinou, Modelling Triple Friction Pendulum Isolators In Program

SAP2000,Report,2010

[4]. ShomaKitayama and Michael C. Constantinou, Evaluation of triple friction pendulum isolator element in

program SAP2000 ,Report, August 27,2015

[5]. Daniel M. Fenz and Michael C. Constantinou, Modeling Triple Friction Pendulum Bearing for response

history analysis, Earthquake spectra, Earthquake Engineering research institute Vol 24(4),1011-1028, 2008

Page 14: SEISMIC RESPONSE OF CABLE STAYED BRIDGE … · SEISMIC RESPONSE OF CABLE STAYED BRIDGE ISOLATED WITH TRIPLE FRICTION ... carried out by using the SAP2000 ... Cable stayed bridge is

215 | P a g e

[6]. Daniel M. Fenz and Michael C. Constantinou, Spherical sliding isolation bearing with adaptive

behavior:Theory, Earthquake engineering and structural dynamics, Vol 37,163-183,2008

[7]. Daniel M. Fenz and Michael C. Constantinou, Spherical sliding isolation bearing with adaptive behavior :

Experimental verification, Earthquake engineering and structural dynamics, Vol 37,185-205,2007

[8]. Wei-Xin Ren and Makoto Obata, Elastic –Plastic seismic behavior of long span cable stayed bridge,

Journal of bridge engineering, Vol 4,194-203,August-1999

[9]. P.H.Wang, T,C,Tseng and C.G.Yang, Initial shape of cable stayed bridge, Computers and structures, Vol

46(6),1095-1106,1993