24
American Standard Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903

Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

  • Upload
    others

  • View
    25

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

American Standard

Selectronic 605XRCTRemote Control

Operation Manual

2013 firmware_2013-0903

Page 2: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

OPERATION: The remote programmer has 4 keys:

“Enter” or validate

“Cancel”

“Scroll UP”

“Scroll Down”The ‘Down’ Key is also used to turn “ON” the remote programmer. After not being used for 2 minutes, the programmer automatically turns itself off.

Mini-USB Port

Transmission Area

2

Page 3: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

When using the programmer, the sensor will begin blinking for approximately 5 seconds after the “enter” key is pressed and the display shows “TRANSMISSION OK”. While it is blinking move your finger to within 1 inch of the sensor (nearly covering it). When the light stops blinking and stays on steady, remove your finger and, with the palm of your hand facing the sensor, move your hand to the distance to be set. When the sensor starts to blink again, move you hand away from the detection area. The flashing will stop and the sensor will now be programmed with the new range setting.

The Programmer will now display BACKUP FUNCTION. You can program the next sensor(s) with the same modes and functions by pointing the programmer at the sensor and pressing the “enter” key. The programmer will remember the programmed settings (other than the manually set range/distance) for approximately 3.5 minutes before turning off.

NOTE: See “Product Settings & Specifications Chart”

Adjusting The Range (Detection Distance)

*** ONLY DONE AFTER SELECTING ALL OTHER MODE SETTINGS ***

3

Page 4: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

ON

MENU 1

CLEANING

MENU 2

DISINFECTION

Press to activate the menus

Press to turn on the programmer

DISINFECTION

DURATION :1 min

Press up or down to adjust time

Align the programmer with the sensor and press to transmit the signal to sensor to activate the DISINFECTION cycle for the selected period of time

MENU 3

DIAGNOSTIC

Align the programmer with the sensor and press to transmit the signal to sensor to activate the DIAGNOSTIC feature. NOTE: Use the up and down arrow keys to scroll through the current settings

Press to go to MENU 2

Press to go to MENU 3

Press to go to MENU 4

To MENU 4

Start

Cleaning

Disinfection

Diagnostics

TIP: Cleaning – Use this mode to disable the sensor for 1 minute. This is sometimes used by the cleaning crew to keep the faucet “off” while cleaning the fitting and or fixture.

TIP: Disinfection – This is typically used in healthcare facilities that conduct periodic high temperature or high anti-bacterial chemical purging of the water lines. The maintenance person should activate this mode and stay present to avoid any users from exposure to the purged water. This ‘mode’ can be activated while in any function (handwash faucet, urinal flush valve, etc..). The duration (run time) can be programmed from 1 minute to 120 minutes in 1 minute intervals.

TIP: Diagnostics – Use this mode to determine the settings of the faucet or flush valve. NOTE: this feature will only work with products made 2008 or newer.

CELEC V 0.7

AMSTDThis display identifies the software version

Press to start the cleaning mode

4

Page 5: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4

PARAMETER

SENSOR

2013 VERSION

SENSOR

2008 VERSION

From MENU 3

MENU 5

PARTIAL COUNT

MENU 6

TOTAL COUNT

NOTE: Not all features available with this version

From this menu, scroll down to the specific mode you want to program:

Parameter

Language

Backlight

• Hand-Wash

• Metering

• On/OFF

• Urinal

• LF Urinal + PF **(NOT USED)**

• Flushometer

• Kitchen **(NOT USED)**

• DB Toilet

TIP: Sensor Version • Select 2013 Version for all

Selectronic products manufactured starting in July 2013.

• Select 2008 Version for all Selectronic products manufactured from 2008 to June 2013.

• Call for Assistance for products manufactured from 2003 through 2007.

• NOTE: Versions 2008 & 2013 will have a label on the sensor terminal to identify the version

SENSOR

2003 VERSION

NOTE: Not all features available with this version

Align the programmer with the sensor and press to transmit the signal to sensor to activate the PARTIAL COUNT feature. (This is the number of activations since the last time the count was checked)

Align the programmer with the sensor and press to transmit the signal to sensor to activate the TOTAL COUNT feature. (This is the number of activations since the sensor was manufactured, and cannot be reset)

To MENU 7

Go To Page 7

Go To Page 14

Call for Assistance

5

Page 6: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 7

LANGUAGE

MENU 7.1

Francais

Press up or down to select language – French, English, Spanish, Italian, or German

MENU 8

BACKLIGHT

BACKLIGHT

Press up or down to select display backlight intensity

Press to set selected language

Press to set selected display intensity for easy reading in different lighting conditions.

From MENU 6

6

Page 7: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

After selecting “SENSOR 2013 VERSION,” scroll down to the specific mode you want to program:

• Hand-Wash

• Metering

• On/OFF

• Urinal

• LF Urinal + PF **(NOT USED)**

• Flushometer

• Kitchen **(NOT USED)**

• DB Toilet

FOR SENSOR 2013 VERSION

7

Page 8: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.1

HAND-WASHER

COMF. Timeout

= 1 Sec

To MENU 4.2

Hand-Wash -- Faucet

From MENU 4

NOTE: This is the standard ‘instant on / instant off’ faucet mode.

TIP: The 'COMF. Timeout' (Comfort Timeout) is how long the water will run after the users' hands are removed from the detection zone. This prevents the water from quickly turning On & Off as the users' hands move in & out of the detection zone. Recommended setting: 1.5 sec (adjustable from 0 to 10 sec in 0.5 sec increments).

TIP: The 'Auto. RINSE' (Auto Purge) allows the faucet to automatically turn ON after a set period time of non use, to prevent the water from becoming stagnant or to maintain the trap seal. This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. Then set the duration of run time from 1 sec. to 240 sec. Default Setting: ‘OFF’

TIP: The 'SAFETY Timeout' is sometimes referred to as the ‘vandal timer’. This feature automatically turns the faucet off after a set period of time to prevent a person from intentionally blocking the eye (with chewing gum, tape, etc.) to keep the faucet running and have the sink overflow. Default Setting: 55 sec(adjustable from 5 to 120 sec in 5 sec increments)

Setting the sensor to the Hand-Wash faucet mode: • Set the 'COMF. Timeout'• Set the 'SAFETY Timeout'• Set 'Auto-RINSE' frequency (if the frequency is set to 0,

‘auto-rinsing' (auto-purging) is Off)• Set 'Auto-RINSE' duration (run time)

FOR SENSOR 2013 VERSION

Auto. RINSE

= OFF

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= 72 h

Auto. RINSE

= 15 s

SENSOR DIST.

= 16 cm

Press up or down to select distance:16 cm (6.3”) is the Default

See TIP

SAFETY Timeout

= 55 s

See TIP

See TIP

Press up or down to adjust the rinse duration

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

8

Page 9: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.2

METERING

From MENU 4.1

To MENU 4.3

Metering -- FaucetSetting the sensor to the Metering faucet mode: • Set the 'COMF. Timeout' (run time)• Set 'Auto. Rinse' frequency (if the frequency is set to 0,

‘auto-rinsing' (auto-purging) is Off)• Set 'Auto. Rinse' duration (run time)• Set 'SENSOR DIST.' (range)

TIP: In this Metering Mode, the 'COMF. Timeout' (Comfort Timeout) is the RUN TIME - how long the water will run once activated by the user. Run Times (sec.): 3.25, 7.5, 10, 15, 30, 60, 120, or 240

TIP: The 'Auto. RINSE' (Auto Purge) allows the faucet to automatically turn ON, after a set period time of non use, to prevent the water from becoming stagnant or to maintain the trap seal . This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. Then set the duration of run time from 1 sec. to 240 sec. Default Setting: ‘OFF’

Auto. RINSE

= OFF

SENSOR DIST.

SHORT RANGE

Align the programmer with the sensor and press to transmit the program to the sensor

Press up or down to select between Short and Long Range –SHORT is the Default

Auto. RINSE

= 72 h

Auto. RINSE

=15s

SENSOR DIST.

= 16 cm

COMF. Timeout

= 15 Sec

Press up or down to adjust the run time

Press up or down to select distance – 16 cm (6.3”) is the Default

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

FOR SENSOR 2013 VERSION

9

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

Page 10: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.3

ON/OFF

From MENU 4.2

COMF. Timeout

= 15 Sec

Press up or down to adjust the run time

Auto. RINSE

= OFF

SENSOR DIST.

SHORT RANGE

Align the programmer with the sensor and press to transmit the program to the sensor

To MENU 4.4

Metering with On/Off -- Faucet

TIP: The 'Auto. RINSE' (Auto Purge) allows the faucet to automatically turn ON, after a set period time of not being used, to prevent the water from becoming stagnant or to maintain the trap seal . This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. You can set the duration of run time from 1 sec. to 240 sec. Default Setting: ‘OFF’

Setting the sensor to the Metering faucet mode: • Set the 'COMF. Timeout' (run time), • Set 'Auto. Rinse' frequency (if the frequency is set to 0,

‘auto-rinsing' (auto-purging) is Off)• Set 'Auto. Rinse' duration (run time)• Set 'SENSOR DIST.' (range)

NOTE: This is actually the ‘Metering’ mode, but with the added feature of being able to start and stop the water flow before the metering time runs out.

TIP: In this ‘Metering with On/Off’ Mode, the 'COMF. Timeout' is the RUN TIME - how long the water will run once activated by the user, The detection distance is set very short, so the user must start & stop the water by moving hands close to the sensor. This is suited for gooseneck type fittings where the movement of the user may be outside the normal detection zone. Run Times (sec.): 3.25, 7.5, 10, 15, 30, 60, 120, or 240

Auto. RINSE

= 72 h

Auto. RINSE

= 15 s

SENSOR DIST.

= 5 cm

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

Press up or down to select between Short and Long Range –SHORT is the Default

Press up or down to select distance – 5 cm (2.0”) is the Default

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

FOR SENSOR 2013 VERSION

10

Page 11: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.4

URINAL

From MENU 4.3

DETEC. INTERVAL

= 5 Sec

Press up or down to adjust the required user detection arming time

RINSE START INT

= 3

Press up or down to adjust how long the valve waits after the user leaves the detection zone to begin the flush

Align the programmer with the sensor and press to transmit the program to the sensor

To MENU 4.5

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

RINSE

= 3 s

**This Function Not Normally Used. See page 21 for information on use of this function.

Urinal -- Urinal Flush ValveTIP: The 'DETEC. INTERVAL' (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Default setting is 5 sec.

TIP: The 'RINSE START INT' (rinse start interval) is how long after the user leaves the detection zone before the valve flushes. Default setting is 3 sec.

TIP: The 'Auto. RINSE' (Sanitary Flush) allows the flush valve to automaticallyflush, after a set period time of not being used, to maintain the trap seal . The Frequency can be set from OFF to 72 hrs (of non-use) in 1 hr.. increments. The Duration of flush time can set from 1 sec. to 240 sec.

Frequency Default Setting: ’ OFF’ (unless prolonged non-use is expected)

NOTE: 'Auto. RINSE' Duration must never deliver more water than the fixture can drain before overflowing!

Recommended 'Duration is 2 sec. (when used)

TIP: The 'RINSE' is the flush time (flush duration). See Flush Valve Settings Chart on page 20

HEAVY FLUSH

COUNT : OFF

Auto. RINSE

= 2 s

SENSOR DIST.

= 40 cm

Press up or down to select distance –40 cm (15.75”) is the Default

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

FOR SENSOR 2013 VERSION

11

Page 12: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.6

FLUSHOMETER

From MENU 4.4

To MENU 4.7

MENU 4.5

LF URINAL + PF

Flushometer – Toilet Flush Valve

MENU 4.7

KITCHENNOT USED

TIP: The 'DETEC. INTERVAL' (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. (Default setting is 5 sec.)

TIP: The 'RINSE START INT' (rinse start interval) is how long after the user leaves the detection zone before the valve flushes. Default setting is 3 sec.

TIP: The 'RINSE' is the flush time (flush duration). See Flush Valve Settings Chart on page 20

DETEC. INTERVAL

= 5 Sec

RINSE START INT

= 3

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

RINSE

= 3 s

**This Function Not Normally Used. See page 21 for information on use of this function.

HEAVY FLUSH

COUNT : OFF

Auto. RINSE

= 2 s

SENSOR DIST.

= 40 cm

NOT USED

Press up or down to select distance –60 cm (23.6”) is Recommended

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

Press up or down to adjust the required user detection arming time

Press up or down to adjust how long the valve waits after the user leaves the detection zone to begin the flush

TIP: The 'Auto. RINSE' (Sanitary Flush) allows the flush valve to automaticallyflush, after a set period time of not being used, to maintain the trap seal . The Frequency can be set from OFF to 72 hrs (of non-use) in 1 hr.. increments. The Duration of flush time can set from 1 sec. to 240 sec.

Frequency Default Setting: ’ OFF’ (unless prolonged non-use is expected)

NOTE: 'Auto. RINSE' Duration must never deliver more water than the fixture can drain before overflowing!

Recommended 'Duration is 2 sec. (when used)

FOR SENSOR 2013 VERSION

12

Page 13: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.8

DB Toilet

From MENU 4.4

DETEC. INTERVAL

= 3 Sec

Press up or down to adjust the user detection arming time

RINSE START INT

= 3

RINSE

= 3 s

Press up or down to adjust Flush Time

Dual Flush – Toilet Flush Valve

SHORT RINSING

= 1.5 Sec

TIP: The 'DETEC. INTERVAL' (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. (Default setting is 5 sec.)

Press up or down to adjust how long the valve waits after the user leaves the detection zone to begin the flush

TIP: The 'SHORT RINSING' is the flush time (flush duration) used when the user stays in the detection zone for less than 60 sec. This should be the setting for the lowest of the 2 flush volumes listed for this model flush valve. See Flush Valve Settings Chart on page 20

TIP: The 'RINSE' is the long flush time (flush duration) if the user stays in the detection zone for 60 sec. or longer. See the Flush Valve Settings Chart on page 20

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

Auto. RINSE

= 2 s

SENSOR DIST.

= 40 cm

**This Function Not Normally Used. See page 21 for information on use of this function.

HEAVY FLUSH

COUNT : OFF

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

Press up or down to select distance –60 cm (23.6”) is Recommended

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

TIP: The 'Auto. RINSE' (Sanitary Flush) allows the flush valve to automatically flush, after a set period time of not being used, to maintain the trap seal . The Frequency can be set from OFF to 72 hrs (of non-use) in 1 hr.. increments. The Duration of flush time can set from 1 sec. to 240 sec.

Frequency Default Setting: ’ OFF’ (unless prolonged non-use is expected)

NOTE: 'Auto. RINSE' Duration must never deliver more water than the fixture can drain before overflowing!

Recommended 'Duration is 2 sec. (when used)

TIP: The 'RINSE START INT' (rinse start interval) is how long after the user leaves the detection zone before the valve flushes. Default setting is 3 sec.

13

FOR SENSOR 2013 VERSION

Page 14: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

After selecting “SENSOR 2008 VERSION,” scroll down to the specific mode you want to program:

• Hand-Wash

• Metering

• On/OFF

• Urinal

• LF Urinal + PF **(NOT USED)**

• Flushometer

• Kitchen **(NOT USED)**

• DB Toilet

FOR SENSOR 2008 VERSION

14

Page 15: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.1

HAND-WASHER

COMF. Timeout

= 1 Sec

To MENU 4.2

Hand-Wash -- Faucet

From MENU 4

NOTE: This is the standard ‘instant on / instant off’ faucet mode.

Setting the sensor to the Hand-wash faucet mode: • Set the ‘COMF. Timeout’• Set the 'SAFETY Timeout'• Set 'Auto. RINSE' frequency (if the frequency is set to 0,

‘auto-rinsing' (auto-purging) is Off)• Set the 'Auto. RINSE' duration (run time)

Auto. RINSE

= OFF

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= 72 h

Auto. RINSE

= 15 s

See TIP

SAFETY Timeout

= 55 s

See TIP

See TIP

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

TIP: The 'COMF. Timeout' (Comfort Timeout) is how long the water will run after the users' hands are removed from the detection zone. This prevents the water from quickly turning On & Off as the users' hands move in & out of the detection zone. Recommended setting: 1.5 sec (adjustable from 0 to 10 sec in 0.5 sec increments).

TIP: The 'Auto. RINSE' (Auto Purge) allows the faucet to automatically turn ON after a set period time of non use, to prevent the water from becoming stagnant or to maintain the trap seal. This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. Then set the duration of run time from 1 sec. to 240 sec. Default Setting: ‘OFF’

TIP: The 'SAFETY Timeout' is sometimes referred to as the ‘vandal timer’. This feature automatically turns the faucet off after a set period of time to prevent a person from intentionally blocking the eye (with chewing gum, tape, etc.) to keep the faucet running and have the sink overflow. Default Setting: 55 sec(adjustable from 5 to 120 sec in 5 sec increments)

FOR SENSOR 2008 VERSION

15

Page 16: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.2

METERING

From MENU 4.1

To MENU 4.3

Metering -- Faucet

Auto. RINSE

= OFF

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= 72 h

Auto. RINSE

= 15 s

COMF. Timeout

= 15 Sec

Press up or down to adjust the run time

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

Setting the sensor to the Metering faucet mode: • Set the 'COMF. Timeout' (run time)• Set 'Auto. Rinse' frequency (if the frequency is set to 0,

‘auto-rinsing' (auto-purging) is Off)• Set 'Auto. Rinse' duration (run time)• Set 'SENSOR DIST.' (range)

TIP: In this Metering Mode, the 'COMF. Timeout' (Comfort Timeout) is the RUN TIME - how long the water will run once activated by the user. Run Times (sec.): 3.25, 7.5, 10, 15, 30, 60, 120, or 240

TIP: The 'Auto. RINSE' (Auto Purge) allows the faucet to automatically turn ON after a set period time of non use, to prevent the water from becoming stagnant or to maintain the trap seal. This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. Then set the duration of run time from 1 sec. to 240 sec. Default Setting: ‘OFF’

FOR SENSOR 2008 VERSION

16

Page 17: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.3

ON/OFF

From MENU 4.2

COMF. Timeout

= 15 Sec

Press up or down to adjust the run time

Auto. RINSE

= OFF

Align the programmer with the sensor and press to transmit the program to the sensor

To MENU 4.4

Auto. RINSE

= 72 h

Auto. RINSE

= 15 s

Press up or down to turn ON the Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

Setting the sensor to the Metering faucet mode: • Set the 'COMF. Timeout' (run time), • Set 'Auto. Rinse' frequency (if the frequency is set to 0,

‘auto-rinsing' (auto-purging) is Off)• Set 'Auto. Rinse' duration (run time)• Set 'SENSOR DIST.' (range)

NOTE: This is actually the ‘Metering’ mode, but with the added feature of being able to start and stop the water flow before the metering time runs out.

TIP: In this ‘Metering with On/Off’ Mode, the 'COMF. Timeout' is the RUN TIME - how long the water will run once activated by the user, The detection distance is set very short, so the user must start & stop the water by moving hands close to the sensor. This is suited for gooseneck type fittings where the movement of the user may be outside the normal detection zone. Run Times (sec.): 3.25, 7.5, 10, 15, 30, 60, 120, or 240

TIP: The 'Auto. RINSE' (Auto Purge) allows the faucet to automatically turn ON after a set period time of non use, to prevent the water from becoming stagnant or to maintain the trap seal. This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. Then set the duration of run time from 1 sec. to 240 sec. Default Setting: ‘OFF’

Metering with On/Off -- FaucetFOR SENSOR 2008 VERSION

17

Page 18: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.4

URINAL

From MENU 4.3

DETEC. INTERVAL

= 5 Sec

Press up or down to adjust the required user detection arming time

RINSE START INT

= 3

Press up or down to adjust how long the valve waits after the user leaves the detection zone to begin the flush

Align the programmer with the sensor and press to transmit the program to the sensor

To MENU 4.5

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

RINSE

= 3 s

Urinal -- Urinal Flush Valve

Auto. RINSE

= 2 s

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

TIP: The 'DETEC. INTERVAL' (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Default setting is 5 sec.

TIP: The 'RINSE START INT' (rinse start interval) is how long after the user leaves the detection zone before the valve flushes. Default setting is 3 sec.

TIP: The 'Auto. RINSE' (Sanitary Flush) allows the flush valve to automaticallyflush, after a set period time of not being used, to maintain the trap seal . The Frequency can be set from OFF to 72 hrs (of non-use) in 1 hr.. increments. The Duration of flush time can set from 1 sec. to 240 sec.

Frequency Default Setting: ’OFF’ (unless prolonged non-use is expected)

NOTE: 'Auto. RINSE' Duration must never deliver more water than the fixture can drain before overflowing!

Recommended 'Duration is 2 sec. (when used)

TIP: The 'RINSE' is the flush time (flush duration). See Flush Valve Settings Chart on page 20

FOR SENSOR 2008 VERSION

18

Page 19: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.6

FLUSHOMETER

From MENU 4.4

To MENU 4.8

MENU 4.5

LF URINAL + PF

Flushometer – Toilet Flush Valve

MENU 4.7

KITCHENNOT USED

DETEC. INTERVAL

= 5 Sec

Press up or down to adjust the required user detection arming time

RINSE START INT

= 3

Press up or down to adjust how long the valve waits after the user leaves the detection zone to begin the flush

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

RINSE

= 3 s

Auto. RINSE

= 2 s

NOT USED

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

TIP: The 'DETEC. INTERVAL' (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. (Default setting is 5 sec.)

TIP: The 'RINSE START INT' (rinse start interval) is how long after the user leaves the detection zone before the valve flushes. Default setting is 3 sec.

TIP: The 'RINSE' is the flush time (flush duration). See Flush Valve Settings Chart on page 20

TIP: The 'Auto. RINSE' (Sanitary Flush) allows the flush valve to automaticallyflush, after a set period time of not being used, to maintain the trap seal . The Frequency can be set from OFF to 72 hrs (of non-use) in 1 hr.. increments. The Duration of flush time can set from 1 sec. to 240 sec.

Frequency Default Setting: ’ OFF’ (unless prolonged non-use is expected)

NOTE: 'Auto. RINSE' Duration must never deliver more water than the fixture can drain before overflowing!

Recommended 'Duration is 2 sec. (when used)

FOR SENSOR 2008 VERSION

19

Page 20: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

MENU 4.8

DB Toilet

From MENU 4.4

DETEC. INTERVAL

= 5 Sec

Press up or down to adjust the user detection arming time.

RINSE START INT

= 3

RINSE

= 3 s

Press up or down to adjust Flush Time –see TIP

Dual Flush – Toilet Flush Valve

SHORT RINSING

= 1.5 Sec

Press up or down to adjust how long the valve waits after the user leaves the detection zone to begin the flush

TIP: The 'RINSE' is the long flush time (flush duration) if the user stays in the detection zone for 60 sec. or longer. See the Flush Valve Settings Chart on page 20

FOR SENSOR 2008 VERSION

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

Auto. RINSE

= 2 s

Press up or down to turn ONthe Auto Rinse feature and adjust frequency

Press up or down to adjust the rinse duration

TIP: The 'DETEC. INTERVAL' (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. (Default setting is 5 sec.)

TIP: The 'Auto. RINSE' (Sanitary Flush) allows the flush valve to automatically flush, after a set period time of not being used, to maintain the trap seal . The Frequency can be set from OFF to 72 hrs (of non-use) in 1 hr.. increments. The Duration of flush time can set from 1 sec. to 240 sec.

Frequency Default Setting: ’ OFF’ (unless prolonged non-use is expected)

NOTE: 'Auto. RINSE' Duration must never deliver more water than the fixture can drain before overflowing!

Recommended 'Duration is 2 sec. (when used)

TIP: The 'RINSE START INT' (rinse start interval) is how long after the user leaves the detection zone before the valve flushes. Default setting is 3 sec.

TIP: The 'SHORT RINSING' is the flush time (flush duration) used when the user stays in the detection zone for less than 60 sec. This should be the setting for the lowest of the 2 flush volumes listed for this model flush valve. See Flush Valve Settings Chart on page 20

20

Page 21: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

URINAL FLUSH VALVE SETTINGS

Model (GPF)

Detect Interval

Rinse Start (Flush Start)

Rinse (Flush-time)

Auto Rinse (Sanitary Flush)

Auto Rinse (run-time)

Innsbrook 5 3 8 OFF or 72h 2

1.0 5 3 6 OFF or 72h 2

0.5 5 3 3 OFF or 72h 1

0.25 5 3 1.5 OFF or 72h 1

0.125 5 3 1 OFF or 72h 1

TOILET FLUSH VALVE SETTINGS

Model (GPF)

Detect Interval

Rinse Start (Flush Start)

Rinse (Flush-time)

Auto Rinse (Sanitary Flush)

Auto Rinse (run-time)

1.6 5 3 3.5 OFF or 72h 2

1.28 5 3 3 OFF or 72h 2

1.1 5 3 2.5 OFF or 72h 2

DUAL-FLUSH VALVE SETTINGSModel (GPF)

Short Rinsing(Short Flush)

Detect Interval

Rinse Start (Flush Start)

Rinse (Flush-time)

Auto Rinse (Sanitary Flush)

Auto Rinse (run-time)

1.6 / 1.1 2.5 5 3 3.5 OFF or 72h 2

1.28 / 1.1 2.5 5 3 3.0 OFF or 72h 2

Flush Valve Settings

Units ConverterCentimeters

(cm)Inches

(in)

5 2

16 6.3

25 9.8

40 15.75

60 23.6

80 31.5

21

Page 22: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

PERIODIC HEAVY FLUSH FEATUREPeriodic Heavy Flush - A slug of water (higher than the standard flush volume) is sent through the drain line after a pre-programmed number of flushes, or specified time period of non-use, to help prevent drain line clogging. The volume and frequency of the slug of water are easily programmable. Flush valves with the Periodic Heavy Flush Feature can be located upstream of ultra-high efficiency fixtures or in areas of potential drain line carry issues. See pages 22 & 23 for water conservation chart and application examples.

The PHF feature can be activated for the Urinal, Flushometer, and Dual Flush functions with the

Sensor 2013 Version.

HEAVY FLUSH

COUNT : OFF

Press up or down to turn on the Heavy Flush feature and set the activation count

HEAVY FLUSH

COUNT = 20

Press up or down to adjust the Heavy Flush run time

HEAVY FLUSH

DURATION : 5 s

From RINSE MENU

Align the programmer with the sensor and press to transmit the program to the sensor

Auto. RINSE

= OFF

Auto. RINSE

= 72 h

Auto. RINSE

= 2 s

Press up or down to turn ON the Auto Rinse (Heavy Flush) feature based on time of non-use and adjust time activation frequency

Press up or down to adjust the heavy flush duration

TIP: The 'HEAVY FLUSH COUNT' feature allows the flush valve to automatically flush a heavy flush after a set number of flush activations, to maintain the drain line. The activation count can be set from OFF to 100 in increments of 10 activations. You can set the duration of flush time from 1 sec. to 240 sec. – never set for more than the fixture can drain before overflowing!

Default setting: 'OFF'

TIP: The 'Auto. RINSE' (HEAVY FLUSH) allows the flush valve to automatically flush after a set period time of not being used, to maintain the drain line. This time period can be set to activate from OFF to 72 hrs (of non-use) in 1 hr. increments. You can set the duration of the heavy flush time from 1 sec. to 240 sec. –never more than the fixture can drain before overflowing!

Default setting: 'OFF'

22

Page 23: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

Water Savings Afforded by PHFD Flush Valves Versus Standard 1.6 GPF Flushing Systems

# ToiletsFlush

VolumeFlushes Per Day

Total Gallons

Savings (gal.)

% Savings vs. 1.6

1.6 GPF Standard Toilets 14 1.6 10 224.0 0 0

1.28 GPF HET Toilets 14 1.28 10 179.2 44.8 20%

1.1 GPF UHET Toilet Systems 14 1.1 10 154.0- 1 Heavy Flush after timed-out period of 'non-use'. 3 1.6 3 14.4

168.4 55.6 25%

1.1 GPF UHET Toilet Systems 14 1.1 8 123.2- 1 Heavy Flush every 5 Flushes 14 1.6 2 44.8

168.0 56.0 25%

1.1 GPF UHET Toilet Systems 11 1.1 10 121.03 1.1 7 23.1

- 3 Heavy Flushes/day for 3 flush valves based on count usage 3 1.6 3 14.4158.5 65.5 29%

23

Page 24: Selectronic 605XRCT Remote Control Operation …...Selectronic 605XRCT Remote Control Operation Manual 2013 firmware_2013-0903 OPERATION: The remote programmer has 4 keys: “Enter”

HET Fixture & Flush Valve (Typ)

Branch Drain/Waste Line (Typ)

Possible application for drain line purge flush from seldom used end of branch line Flush Valve. Flush cycle is based on period of non-use.

Possible application for branch drain line purge flush from end Flush Valve. Flush cycle is based on period of non-use.

Possible application for drain line purge flush from frequently used Flush Valve. Flush cycle is based on number of uses.

Using PHFD To Address Drain Line Carry-out With UHET & HET Fixtures

Drain Line SagPossible application for a

drain line purge flush to overcome potential clogging due to drain line sag and low flow fixtures

24