4
Self Priming Monoblock Pump Hi-Flow Series

Self Priming Monoblock Pump · 2020-06-03 · Self-Priming Monoblock Pumps HI-FLOW SERIES • Operating water temperature: upto 65° • Max working pressure: 5.5 Kg/cm • High suction

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Self Priming Monoblock Pump · 2020-06-03 · Self-Priming Monoblock Pumps HI-FLOW SERIES • Operating water temperature: upto 65° • Max working pressure: 5.5 Kg/cm • High suction

Self PrimingMonoblock Pump

Hi-Flow Series

Page 2: Self Priming Monoblock Pump · 2020-06-03 · Self-Priming Monoblock Pumps HI-FLOW SERIES • Operating water temperature: upto 65° • Max working pressure: 5.5 Kg/cm • High suction

Self-Priming Monoblock Pumps HI-FLOW SERIES

• Operating water temperature: upto 65°• Max working pressure: 5.5 Kg/cm• High suction with self-priming: upto 8 metre•• Wide voltage operating range (180-240V)• Direction of rotation: Anti-Clockwise when viewed

from driving end

C2

Low power consumption

•Impeller: Forged brass for longer life

• Brass insert* on impeller housing for rust free operation• Shaft: Stainless steel• Mechanical seal*: Silicon carbide-graphite• Copper winding• In-built non return valve

Pump Casing: Cast iron•

Operating Conditions

•• Used in gardening, farm houses & building construction• For lifting water to overhead storage tanks• Pressure booster systems• Hotels, hospitals and fountains• Water circulation in Industries

Domestic water supply in bungalows and apartments

•• Motor Stator: Low watt loss silicon steel laminations• Rotor: Dynamically balanced• TEFC motor (2900 RPM) suitable for 180-240V, 50 Hz

single phase AC power supply• In-built thermal overload protector (T.O.P.) • Provided with 1 meter long power supply cable• Motor Insulation Class F• Motor protection IP-55

Motor body: High quality aluminum pressure die casted

Pump ConstructionApplications

Motor

Self-Priming Monoblock Pumps

Performance Data

Model H A B K AB BB AA AD AC HA L HE G.Wt. (kg) Hi-Flow V1 80 125 100 14 153 125 35 209 159 9.5 300 202 15

Hi-Flow S1 80 125 100 14 153 125 35 196 159 9.5 297 211 15

Hi-Flow V2 71 112 90 11 135 109 31 174 137 8 260 172 10.5

Hi-Flow S2 71 112 90 11 135 109 31 162 137 8 260 176 10.5

l The performance data are at rated voltage and only indicative, actual discharge depends on availability of water and installation of pump. l In view of continous development the information, performance, description, specifications mentioned in this catalogue are subject to

change without notice. For latest information and updates, please get in touch with us.# Available from Nov. 2013 onwards.

HI-FLOW SERIES

13

18

26

2524

2322

21

17

1615

14

4

2 6

5

7

8

12

10

11

9

13

20

19

*Brass inserts1"BSP

AE

AC

B

BB

K

L

Dimension (in mm)

AD

H

HAAA

A

AB

HE

1"B

SP

0

5

10

15

20

25

30

35

40

45

50

55

60

0 500 1000 1500 2000 2500 3000 3500 4000 4500

Hea

d (m

)

Flow Rate ( L / h )

Hi-Flow V1

Hi-Flow S1

Hi-Flow V2

Hi-Flow S2

6 9 12 15 18 21 24 27 30 33 34 40 45 50 56

KW HP ( mm )

Hi-Flow V2 0.37 0.5 25 x 25 2700 2630 2430 2230 1950 1650 1440 1160 980 690 650

Hi-Flow S2 0.37 0.5 25 x 25 2700 2550 2350 2150 1870 1570 1360 1080 900 610 490

Hi-Flow V1 0.75 1.0 25 x 25 4250 4090 3950 3690 3440 3210 2970 2690 2510 2250 2190 1820 1450 1180 730

Hi-Flow S1 0.75 1.0 25 x 25 4200 4000 3860 3600 3350 3120 2880 2600 2420 2160 2100 1730 1360 1090 640

Model Power

Pipe Size

Suc. x Del.

Total Head in Metres

Discharge in LPH

V- Series Pump

No. Component No. Component1 Suction flange 14 Impeller2 Non return valve 15 Mechanical seal3 Threaded plug 16 O-ring4 Flange gasket 17 Wound stator5 Vent plug 18 Motor housing6 Vent plug washer 19 Power supply cable7 Delivery flange 20 Waterproof ring8 Pump Adaptor 21 Rotor9 Terminal block 22 Wavy washer10 Terminal block cover 23 End cover11 Capacitor 24 Tie rod12 Bearing 25 Fan13 Pump casing 26 Fan cover

*Hi-Flow V series pumps.

S- Series pump

Performance Curve

Page 3: Self Priming Monoblock Pump · 2020-06-03 · Self-Priming Monoblock Pumps HI-FLOW SERIES • Operating water temperature: upto 65° • Max working pressure: 5.5 Kg/cm • High suction

Self-Priming Monoblock Pumps HI-FLOW SERIES

• Operating water temperature: upto 65°• Max working pressure: 5.5 Kg/cm• High suction with self-priming: upto 8 metre•• Wide voltage operating range (180-240V)• Direction of rotation: Anti-Clockwise when viewed

from driving end

C2

Low power consumption

•Impeller: Forged brass for longer life

• Brass insert* on impeller housing for rust free operation• Shaft: Stainless steel• Mechanical seal*: Silicon carbide-graphite• Copper winding• In-built non return valve

Pump Casing: Cast iron•

Operating Conditions

•• Used in gardening, farm houses & building construction• For lifting water to overhead storage tanks• Pressure booster systems• Hotels, hospitals and fountains• Water circulation in Industries

Domestic water supply in bungalows and apartments

•• Motor Stator: Low watt loss silicon steel laminations• Rotor: Dynamically balanced• TEFC motor (2900 RPM) suitable for 180-240V, 50 Hz

single phase AC power supply• In-built thermal overload protector (T.O.P.) • Provided with 1 meter long power supply cable• Motor Insulation Class F• Motor protection IP-55

Motor body: High quality aluminum pressure die casted

Pump ConstructionApplications

Motor

Self-Priming Monoblock Pumps

Performance Data

Model H A B K AB BB AA AD AC HA L HE G.Wt. (kg) Hi-Flow V1 80 125 100 14 153 125 35 209 159 9.5 300 202 15

Hi-Flow S1 80 125 100 14 153 125 35 196 159 9.5 297 211 15

Hi-Flow V2 71 112 90 11 135 109 31 174 137 8 260 172 10.5

Hi-Flow S2 71 112 90 11 135 109 31 162 137 8 260 176 10.5

l The performance data are at rated voltage and only indicative, actual discharge depends on availability of water and installation of pump. l In view of continous development the information, performance, description, specifications mentioned in this catalogue are subject to

change without notice. For latest information and updates, please get in touch with us.# Available from Nov. 2013 onwards.

HI-FLOW SERIES

13

18

26

2524

2322

21

17

1615

14

4

2 6

5

7

8

12

10

11

9

13

20

19

*Brass inserts1"BSP

AE

AC

B

BB

K

L

Dimension (in mm)

AD

H

HAAA

A

AB

HE

1"B

SP

0

5

10

15

20

25

30

35

40

45

50

55

60

0 500 1000 1500 2000 2500 3000 3500 4000 4500

Hea

d (m

)

Flow Rate ( L / h )

Hi-Flow V1

Hi-Flow S1

Hi-Flow V2

Hi-Flow S2

6 9 12 15 18 21 24 27 30 33 34 40 45 50 56

KW HP ( mm )

Hi-Flow V2 0.37 0.5 25 x 25 2700 2630 2430 2230 1950 1650 1440 1160 980 690 650

Hi-Flow S2 0.37 0.5 25 x 25 2700 2550 2350 2150 1870 1570 1360 1080 900 610 490

Hi-Flow V1 0.75 1.0 25 x 25 4250 4090 3950 3690 3440 3210 2970 2690 2510 2250 2190 1820 1450 1180 730

Hi-Flow S1 0.75 1.0 25 x 25 4200 4000 3860 3600 3350 3120 2880 2600 2420 2160 2100 1730 1360 1090 640

Model Power

Pipe Size

Suc. x Del.

Total Head in Metres

Discharge in LPH

V- Series Pump

No. Component No. Component1 Suction flange 14 Impeller2 Non return valve 15 Mechanical seal3 Threaded plug 16 O-ring4 Flange gasket 17 Wound stator5 Vent plug 18 Motor housing6 Vent plug washer 19 Power supply cable7 Delivery flange 20 Waterproof ring8 Pump Adaptor 21 Rotor9 Terminal block 22 Wavy washer10 Terminal block cover 23 End cover11 Capacitor 24 Tie rod12 Bearing 25 Fan13 Pump casing 26 Fan cover

*Hi-Flow V series pumps.

S- Series pump

Performance Curve

Page 4: Self Priming Monoblock Pump · 2020-06-03 · Self-Priming Monoblock Pumps HI-FLOW SERIES • Operating water temperature: upto 65° • Max working pressure: 5.5 Kg/cm • High suction

Regional & Branch Offices:

NORTH - REGIONAL OFFICE: Corporate Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-4771000, Fax: 0120-4772000, Delhi: Tel: 011-47676700, 23888200, Fax: 011-47676750, 23888250, Chandigarh: Tel: 0172-4232400-401, Fax: 0172-4232403, Dehradun: Tel: 0135-6670202, Fax: 0135-6670203,Noida / Haryana: Tel: 0120-4771000, Fax: 120-4772000, Ludhiana: Tel: 0161-4676001 / 6024, Fax: 0161-46766007, Jammu: Tel: 0191-2490424, Fax: 0191-2490405, Sri Nagar: Tel / Fax: 0194-2490431, Jaipur: Tel: 0141-3988210, Fax: 0141-2389024, Jodhpur: Tel: 0141-3914645, 3988210, Lucknow: Tel: 0522-2201032, 2200938, Kanpur: Tel: Airtel: 09935533751/52/53, 0512-2690128/129/130, Fax: 0512-2692800 EAST - REGIONAL OFFICE: Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851 / 52, Fax: 033-40127339, Bhubaneshwar: Tel:0674-6668101/102/103/104, Fax: 0674-2598107, Guwahati: Tel: 0361-2134521, 2458923, Fax: 0361-2460355, Siliguri: Tel: 0353-2525907, Fax: 0353-3290402 (RIM), Jamshedpur: Tel: 0657-6542492, 09234369436, Patna: Tel: 0612-2207221, 2207222, 2207223, Telefax: 0612-2655518 WEST - REGIONAL OFFICE: Mumbai: 301, Everest House, 3rd Floor, 6, Suren Road, Chakala, Andheri (E). Mumbai - 400 093, Tel: 022-67298600-602 & Fax: 022- 67298603-604, Ahmedabad: Tel: 079-40061111, 40060738-740, Fax: 079-40060741, Indore: Tel: 0731-2572340-41, 4009998 (Airtel), Fax: 0731-2551626, Rajkot: Tel: 0281-2481112, 2921212, Fax: 2481112, Nagpur: Tel: 0712-2224132, 2222692, 2222029, Pune: Tel: 020-64016413 / 14, Raipur: Tel: 0771-4243400 / 01, Telefax: 0771- 4243402, Surat: Tel: 09979890137, Telefax: 0261-2350137, Jabalpur: Tel: 0761-4064491 SOUTH - REGIONAL OFFICE: Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008, Tel: 044-42280600,605, Fax: 044-28524326, Bangalore: Tel: 080-49075000, 9844085913, Fax: 080-25582663, Coimbatore: Telefax: 0422-2305767, 2306199, 2305199, Hyderabad: Tel:040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Fax: 040-27533211, Kochi: Tel: 0484-4099000, Fax: 0484-2393170, Vishakapatnam: Tel: 0891-6514339, Fax: 0891-2522547, Vizag: Tel: 0891-6514339, Fax: 0891-25522547, Vijayawada: Tel: 91+9247058847/57, Calicut: 09895855499, Madurai: 09994493242,Trivandrum: 09633817795, Hubli: 09448146028, Trichy: 09944460160

Representative Offices: • Goa • Solapur • Gwalior • Kathmandu • Bhopal

ZHM

RC

0000

3/O

CT/

13

Ventilair Fan Industrial FanPortable Fan

Mixer Grinder

Steam Iron

Toaster & Sandwich Press OTG

Switchgear Distribution Board

CFL Luminaires

Wires & Cables

3 Phase Electric MotorSwitches

Ceiling Fan

Electric Kettle Coffee MakerAir Fryer

MCCB

Water Heater

Havells India Ltd.QRG Towers, 2D, Sector -126, Expressway, Noida - 201 304 (UP), Ph. +91-120-4771000,E-mail: [email protected], www.havells.comJoin us on Facebook at www.facebook.com/havells and share your ways to save the planet!