14
Sensors MUT 2200 EL / MUT 2500 EL DS100-4-ENG Electromagnetic flowmeters 1/14 dg: www.oryana.com.ar NEW

Sensors MUT 2200 EL / MUT 2500 EL - Metrotek …€¦ · Sensors MUT 2200 EL / MUT 2500 EL ... EUROMAG converters (see Table 5). In the separate version the ... MC 106 A MC 106 B

Embed Size (px)

Citation preview

Sensors MUT 2200 EL / MUT 2500 ELDS100-4-ENG

Electromagnetic flowmeters

1/14

dg: w

ww

.ory

ana.

com

.ar

NEW

MUT 2200 EL / MUT 2500 EL sensors represent the state of the art of EUROMAG INTERNATIONAL production for water cycle

and process applications. The new structure for the generation of the magnetic field, the innovative route of the signal

generated by the electrodes, provide a sensor with an extremely wide measurement range:

EL= Extended Linearity.

This new sensors series follows the successful tradition of the MUT 2200 / MUT 2500, introducing a measurement range of

more than 1:1000 without linearization software. These kinds of performances allow very accurate measures on a wide flow

rate range and to count lower flow rates that, before, would have been reset because of the effect of the converters cut off.

This flanged sensors series bases its operation on the Faraday Principle, by which a conductor crossing a magnetic field

generates a potential perpendicularly orientated to the same field. In this case the flow tube made in stainless steel AISI 304 is

equipped with carbon or stainless steel flanges, two coils are installed on the top and inferior part; the magnetic field,

generated by the electric current crossing the coil, induces in the electrodes a difference in the potential proportional to the

flow rate. With the aim of measuring such potential of very low values, the interior of the flow tube is electrically insulated,

thus the process liquid is no longer in contact neither with the material of the flow tube nor with that of the flange.The

converter used generates the current supplying the coil, acquires the electrodes difference of potential, process the signal to

calculate the flowrate and administers the communication with the exterior. The entire sensor, when installed in the separate

version, has a degree of protection IP 68 suitable for a permanent immersion in water up to a depth of 1.5m thanks to a

welded plate structure containing the coil and the electrodes.

1. Body and flange

The flange and the sensor external surface are acrylic painted. This

treatment gives the sensor an excellent resistance to water, even in

permanent immersion. When special ambient conditions require it,

the MUT 2000 EL / MUT 2500 EL may be supplied in stainless steel,

flange included (see Table 2).

2. Internal lining

The standard internal insulating lining is in PTFE for diameters from

ND 15 to ND 50, in hard rubber (ebonite for food) for diameters of

more than ND 50. On request, the sensors may be supplied coated

with PTFE with diameters of more than ND 50. The temperature of

the liquid to be measured is limited by the kind of internal lining

used. (see Table 4).

3. Electrodes

The standard electrodes are in Hastelloy C and, therefore, guarantee

a wide compatibility with the process liquids, if required, they may

be supplied in the materials shown in Table 3.

Sensors MUT 2200 EL / MUT 2500 EL

2/14

4. Coupling and connecting to sensor

MUT 2200 EL / MUT 2500 EL sensors may be coupled with any

EUROMAG converters (see Table 5). In the separate version the

sensor is connected to the converter by means of a cable whose

length depends on the liquid conductivity; the maximum length not

exceeding 100 metres as shown in Figure 1. If these sensors are

inserted in a plastic or lined pipe line, they require the use of two

grounding rings of the liquid, which are inserted between the flange

and the counter flange or the installation of the grounding electrode.

An empty pipe device is also available .

5. Choice of diameter

When choosing the diameter we advice keeping at the full scale flow

rate, a liquid velocity of at least 2÷3 m/s. The maximum acceptable

velocity is of 10 m/s. Figure 3 provides the flow rate for each ND

(nominal diameter) according to the liquid velocity.

table 1

millimeters (mm)

inches ( " )

150

6"

200

8"

250

10"

300

12"

350

14"

400

16"

millimeters (mm)

inches ( " )

65

2.1/2"

80

3"

100

4"

125

5"

millimeters (mm)

inches ( " )

600

24"

700

28"

800

32"

900

36"

1000

40"

1200

48"

450

18"

500

20"

millimeters (mm)

inches ( " )

1500

60"

1600

64"

1700

68"

1800

72"

2000

80"

1300

52"

1400

56"

15

1/2"

20

3/4"

25

1"

32

1.1/4"

40

1.1/2"

50

2"

Standard diameters

3/14

6. Maximum temperature of the liquid

In the separate version the maximum liquid temperature allowed is

shown in Table 4. In the compact version instead, the maximum

temperature allowed depends on the ambient temperature. This is

due to the required cooling of the electronics. The maximum liquid

temperature allowed for the compact version should be 80ºC.

7. Calibration and maximum error

MUT 2200 EL / MUT 2500 EL sensors belong to the reference Group

B1 (ISO 11631). Each sensor is calibrated by a hydraulic bench

equipped with a reference weighting system and SIT certified. The

uncertainty of the measure is equal to 0.2% of the read flowrate

value when the velocity of the liquid is more than 0.2 m/s. The

repeatability of the measure is in the order of 0.1%

8. Reference standards

The EUROMAG magnetic meters are marked CE and are

manufactured according to the following standards:

* CEI EN 61010-1 * EN 50081 - 1

* UNI EN ISO 6817 * EN 50082 - 1

* 2006/95/CE, 93/68 (LVD) * EN 1434

* 2004/98/CE, 92/31 (EMC)

On request, MUT 2200 EL and MUT 2500 EL sensors can be provided

with certification ATEX II 2 GD EEx mb IIC T4 U.

9. Applications The sensors of the family MUT 2200 EL / MUT 2500 EL are suitable

for any application of on-line mensuration. These sensors are

typically used in the mensure of potable o reflow water, industrial

waste water, industrial process liquids, mud and concretes.

Flow tube materials

AISI 304 (Inox)

Flanges materials

Carbon Steel Painted (std)

AISI 304 (Inox)

AISI 316 (Inox)

table 3

table 2

Hastelloy C (std)

Hastelloy B

Titanium

Tantalum

Platinum

Available electrodes

Maximum length of cables according to the liquid conductivity

figure 1

120

100

80

60

40

20

0

0 50 100 150 200 250 300

Max

imum

leng

th o

f cab

les

(m)

Conductivity ( us/cm )

Internal lining - Liquid temperature

table 4

4/14

Fig. 2 - Overall dimensions.

Internal lining Liquid temperature

PTFE

EBANITE FOR FOOD

Standard -40 /+140°C (up to +180° on request)

-40°C / +80°C

General characteristics of Sensor MUT2200 EL / MUT 2500 EL

600

24"

700

28"

800

32"

900

36"

1000

40"

1200

48"

450

18"

500

20"

1500

60"

1600

64"

1700

68"

1800

72"

2000

80"

1300

52"

1400

56"

MC 106 A MC 106 B MC 308 MC 108

Available diameters

Standard flanged connections

Flanged connections on request

Standard operation pressure [1]

Degree of protection

Converters compatibility

Dimensions

Parts in contact with the liquid [2]

Electrical connections

table 5

16 bar

IP68 continuous immersion at 1,5 m (IEC 529)

MC 308 C

See figure 2

PTFE Ebonite for food stuff

Cableglands PG 11 + terminal box + sealing resin

[1] On request up to 150 bar

[2] Others on request.

ANSI 300 UNI2223 ANSI 150 DIN2501

ISO7005BS45404 AWWA KS

150

6"

200

8"

250

10"

300

12"

350

14"

400

16"

65

2.1/2"

80

3"

100

4"

125

5"

15

1/2"

32

1.1/4"

40

1.1/2"

50

2"

20

3/4"

25

1"

35.5

53.5

No. 2M20x1.5

60

DN

N holes Ø S on Ø D6

Earthing pointM5

= =

L4= =

Ø 104

Ø D

5

H

126

Ø SJ

Only for DN > 400

5/14

table 7

table 6

table 9

table 8

MUT 2200 EL Separate PN10

L4

200

200

200

200

200

200

200

200

250

250

300

350

450

500

550

600

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-5

0-5

0-5

0-5

J

114.5

114.5

104.5

111

113.5

121.5

129.5

136

148.5

161.5

175.5

201

228

253.5

269.5

294.5

4

4

4

4

4

4

4

4

8

8

8

8

12

12

16

16

N

168

168

158

164.5

167

175

183

189.5

202

215

229

254.5

281.5

307

323

348

H

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

84

84

64

77

82

98

114

127

152

178

206

257

311

362

394

444

Ø D5

65

75

85

100

110

125

145

160

180

210

240

295

350

400

460

515

Ø D6

14

14

14

18

18

18

18

18

18

18

22

22

22

22

22

25

Ø S

MUT 2500 EL Separate PN10

L4

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

0-7

0-9

0-9

0-9

0-9

0-15

0-15

0-15

0-15

0-15

0-15

0-15

0-15

J

332

357.5

413.5

464

515

570.5

621.5

728.5

828.5

880.5

928.5

1033.5

1133.5

20

20

20

24

24

28

28

32

36

40

44

48

N

385.5

411

467

517.5

568.5

624

675

782

882

934

982

1087

1187

H

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

519

570

682

783

885

996

1098

1312

1512

1616

1712

1922

2122

Ø D5

565

620

725

840

950

1050

1160

1380

1590

1820

2020

2230

Ø D6

25

25

30

30

33

33

36

39

42

48

48

48

Ø S

MUT 2200 EL Separate PN16

L4

200

200

200

200

200

200

200

200

250

250

300

350

450

500

550

600

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-5

0-5

0-5

0-5

J

114.5

114.5

104.5

111

113.5

121.5

129.5

136

148.5

161.5

175.5

201

228

253.5

269.5

294.5

4

4

4

4

4

4

4

8

8

8

8

12

12

12

16

16

N

168

168

158

164.5

167

175

183

189.5

202

215

229

254.5

281.5

307

323

348

H

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

84

84

64

77

82

98

114

127

152

178

206

257

311

362

394

444

Ø D5

65

75

85

100

110

125

145

160

180

210

240

295

355

410

470

525

Ø D6

14

14

14

18

18

18

18

18

18

18

22

22

25

25

25

30

Ø S

MUT 2500 EL Separate PN16

L4

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

0-7

0-9

0-9

0-9

0-9

0-15

0-15

0-15

0-15

0-15

0-15

0-15

0-15

J

332

357.5

413.5

464

515

570.5

621.5

728.5

828.5

880.5

928.5

1033.5

1133.5

20

20

20

24

24

28

28

32

36

40

44

48

N

385.5

411

467

517.5

568.5

624

675

782

882

934

982

1087

1187

H

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

519

570

682

783

885

996

1098

1312

1512

1616

1712

1922

2122

Ø D5

585

605

770

840

950

1050

1170

1390

1590

1820

2020

2230

Ø D6

30

33

36

36

39

39

42

48

48

56

56

62

Ø S

6/14

table 11

table 10

table 13

table 12

MUT 2200 EL Separate PN25

L4

200

200

200

200

200

200

200

200

250

250

300

350

450

500

550

600

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-5

0-5

0-5

0-5

J

114.5

114.5

104.5

111

113.5

121.5

129.5

136

148.5

161.5

175.5

201

228

253.5

269.5

294.5

4

4

4

4

4

4

8

8

8

8

8

12

12

16

16

16

N

168

168

158

164.5

167

175

183

189.5

202

215

229

254.5

281.5

307

323

348

H

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

84

84

64

77

82

98

114

127

152

178

206

257

311

362

394

444

Ø D5

65

75

85

100

110

125

145

160

190

220

250

310

370

430

490

550

Ø D6

14

14

14

18

18

18

18

18

22

25

25

25

30

30

33

36

Ø S

MUT 2500 EL Separate PN25

L4

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

0-7

0-9

0-9

0-9

0-9

0-15

0-15

0-15

0-15

0-15

0-15

0-15

0-15

J

332

357.5

413.5

464

515

570.5

621.5

728.5

828.5

880.5

928.5

1033.5

1133.5

20

20

20

24

24

28

28

N

385.5

411

467

517.5

568.5

624

675

782

882

934

982

1087

1187

H

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

519

570

682

783

885

996

1098

1312

1512

1616

1712

1922

2122

Ø D5

600

660

770

875

990

1090

1210

Ø D6

36

36

39

42

48

48

56

Ø S

MUT 2200 EL Separate PN40

L4

200

200

200

200

200

200

200

200

250

250

300

350

450

500

550

600

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-5

0-5

0-5

0-5

J

114.5

114.5

104.5

111

113.5

121.5

129.5

136

148.5

161.5

175.5

201

228

253.5

269.5

294.5

4

4

4

4

4

4

8

8

8

8

8

12

12

16

16

16

N

168

168

158

164.5

167

175

183

189.5

202

215

229

254.5

281.5

307

323

348

H

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

84

84

64

77

82

98

114

127

152

178

206

257

311

362

394

444

Ø D5

65

75

85

100

110

125

145

160

190

220

250

320

385

450

510

585

Ø D6

14

14

14

18

18

18

18

18

22

25

25

30

33

33

36

39

Ø S

MUT 2500 EL Separate PN40

L4

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

0-7

0-9

0-9

0-9

0-9

0-15

0-15

0-15

0-15

0-15

0-15

0-15

0-15

J

332

357.5

413.5

464

515

570.5

621.5

728.5

828.5

880.5

928.5

1033.5

1133.5

20

20

20

24

N

385.5

411

467

517.5

568.5

624

675

782

882

934

982

1087

1187

H

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

519

570

682

783

885

996

1098

1312

1512

1616

1712

1922

2122

Ø D5

610

670

795

900

Ø D6

39

42

48

48

Ø S

7/14

table 15

table 14

table 17

table 16

MUT 2200 EL Separate ANSI 150

L4

200

200

200

200

200

200

200

200

250

250

300

350

450

500

550

600

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-5

0-5

0-5

0-5

J

114.5

114.5

104.5

111

113.5

121.5

129.5

136

148.5

161.5

175.5

201

228

253.5

269.5

294.5

4

4

4

4

4

4

4

4

8

8

8

8

12

12

12

16

N

168

168

158

164.5

167

175

183

189.5

202

215

229

254.5

281.5

307

323

348

H

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

84

84

64

77

82

98

114

127

152

178

206

257

311

362

394

444

Ø D5

60.3

69.8

79.4

88.9

98.4

120.6

139.7

152.4

190.5

215.9

241.3

298.4

361.9

431.8

476.2

539.7

Ø D6

16

16

15.9

15.9

15.9

19

19

19

19

22.2

22.2

22.2

25.4

25.5

28.6

28.6

Ø S

MUT 2500 EL Separate ANSI 150

L4

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

0-7

0-9

0-9

0-9

0-9

0-15

0-15

0-15

0-15

0-15

0-15

0-15

0-15

J

332

357.5

413.5

464

515

570.5

621.5

728.5

828.5

880.5

928.5

1033.5

1133.5

16

20

20

28

28

32

36

44

48

52

N

385.5

411

467

517.5

568.5

624

675

782

882

934

982

1087

1187

H

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

519

570

682

783

885

996

1098

1312

1512

1616

1712

1922

2122

Ø D5

577.6

635

749.3

863.6

977.9

1085.9

1200

1422.4

1651

1760

Ø D6

31.7

31.7

34.9

35

41

41

41

41

47.8

47.8

Ø S

MUT 2200 EL Separate ANSI 300

L4

200

200

200

200

200

200

200

200

250

250

300

350

450

500

550

600

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-3

0-5

0-5

0-5

0-5

J

114.5

114.5

104.5

111

113.5

121.5

129.5

136

148.5

161.5

175.5

201

228

253.5

269.5

294.5

4

4

4

4

4

8

8

8

8

8

12

12

16

16

20

20

N

168

168

158

164.5

167

175

183

189.5

202

215

229

254.5

281.5

307

323

348

H

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

84

84

64

77

82

98

114

127

152

178

206

257

311

362

394

444

Ø D5

66.7

82.5

88.9

98.4

114.3

127

149.2

168.3

200

234.9

269.9

330.2

387.3

450.8

514.3

571.5

Ø D6

16

19

19

19

22.2

19

22.2

22.2

22.2

22.2

22.2

25.4

28.6

31.7

31.7

34.9

Ø S

MUT 2500 EL Separate ANSI 300

L4

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

0-7

0-9

0-9

0-9

0-9

0-15

0-15

0-15

0-15

0-15

0-15

0-15

0-15

J

332

357.5

413.5

464

515

570.5

621.5

728.5

828.5

880.5

928.5

1033.5

1133.5

24

24

24

28

28

32

32

32

28

32

N

385.5

411

467

517.5

568.5

624

675

782

882

934

982

1087

1187

H

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

519

570

682

783

885

996

1098

1312

1512

1616

1712

1922

2122

Ø D5

628.6

685.8

812.8

939.8

1054.1

1168.4

1155.7

1371.6

1600.2

1701.8

Ø D6

34.9

34.9

41.3

44.5

50.8

53.8

44.5

50.8

60.5

60.5

Ø S

Fig. 3 - MUT 2200 EL / MUT 2500 EL Compact - Converter MC 106 Horizontal ABS Case

table 18

8/14

158

142

663

H1

H

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

MUT

220

0 EL

MUT

250

0 EL

93

99.5

102

110

118

124.5

137

150

164

189.5

216.5

242

258

283

320.5

346

402

452.5

503.5

559

610

717

818

869

917

1022

1122

H

159

165.5

168

176

184

190.5

203

216

230

255.5

282.5

308

324

349

386.5

412

468

518.5

569.5

625

676

783

883

935

983

1088

1188

H1

222

149

99.5

3 H1

H

table 19

Fig. 4 - MUT 2200 EL / MUT 2500 EL Compact - Converter MC 308 Horizontal ABS Case

9/14

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

MUT

220

0 EL

MUT

250

0 EL

93

99.5

102

110

118

124.5

137

150

164

189.5

216.5

242

258

283

320.5

346

402

452.5

503.5

559

610

717

817

869

917

1022

1122

H

192.5

199

201.5

209.5

217.5

224

236.5

249.5

263.5

289

316

341.5

357.5

382.5

420

445.5

501.5

552

603

658.5

709.5

816.5

916.5

968.5

1016.5

1121.5

1221.5

H1

table 20

10/14

Fig. 5 - MUT 2200 EL / MUT 2500 EL Compact - Converter MC 308 Vertical ABS Case

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

MUT

220

0 EL

105

111.5

114

122

130

136.5

149

162

176

201.5

228.5

254

270

295

H

327

333.5

336

344

352

358.5

371

384

398

423.5

450.5

476

492

517

H1

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

MUT

250

0 EL

332.5

358

414

464.5

515.5

571

622

729

829

881

929

1034

1134

H

554.5

580

636

686.5

737.5

793

844

951

1051

1103

1151

1256

1356

H1

149154

46.5 107.5

12

H1

222

11/14

Fig. 6 - MUT 2200 EL / MUT 2500 EL Compact - Converter MC 108 / 308 Vertical Alluminium Case

table 21

25

32

40

50

65

80

100

125

150

200

250

300

350

400

Ø DN

MUT

220

0 EL

103

109.5

112

120

128

134.5

147

160

174

199.5

226.5

252

268

293

H

358

364.5

367

375

383

389.5

402

415

429

454.5

481.5

507

523

548

H1

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

MUT

250

0 EL

330.5

356

412

462.5

513.5

569

620

727

827

879

927

1032

1132

H

585.5

611

667

717.5

768.5

824

875

982

1082

1134

1182

1287

1387

H1

176 46.5 123169.5

10

H1

H25

5

table 22

12/14

Fig. 7 - MUT 2200 EL / MUT 2500 EL Compact - Converter MC 308 C

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

800

900

1000

1200

1400

1500

1600

1800

2000

Ø DN

MUT

220

0 EL

MUT

250

0 EL

32

38.5

41

49

57

63.5

76

89

103

128.5

155.5

181

197

222

259.5

285

341

391.5

442.5

498

549

656

756

808

856

961

1061

H

215

221.5

224

232

240

246.5

259

272

286

311.5

338.5

364

380

405

442.5

468

524

574.5

625.5

681

732

839

939

991

1039

1144

1244

H1

117

175

H1

183

67.5

63.5

52H

DN

POSSIBLE ROTATIONSUPERIOR VIEW

MC 308 Cwww.euromag.it

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

550

600

650

700

750

800

900

1000

1200

1300

1400

1500

1600

1700

1800

2000

DN VELOCITY [m/s]

l/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

88,36

0,14

0,23

0,35

0,60

0,90

1,41

2,21

3,18

5,65

8,84

12,72

17,32

22,62

28,63

35,34

42,76

50,89

59,73

69,27

79,52

90,48

114,51

141,37

203,58

238,92

277,09

318,09

361,91

408,56

458,04

565,49

883,57

1,45

2,26

3,53

5,97

9,05

14,14

22,09

31,81

56,55

88,36

127,23

173,18

226,19

286,28

353,43

427,65

508,94

597,30

692,72

795,22

904,78

1.145,11

1.413,72

2.035,75

2.389,18

2.770,88

3.180,86

3.619,11

4.085,64

4.580,44

5.654,87

l/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

l/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

8.835,73

14,48

22,62

35,34

59,73

90,48

141,37

220,89

318,09

565,49

883,57

1.272,35

1.731,80

2.261,95

2.862,78

3.534,29

4.276,49

5.089,38

5.972,95

6.927,21

7.952,16

9.047,79

11.451,11

14.137,17

20.357,52

23.891,81

27.708,85

31.808,63

36.191,15

40.856,41

45.804,42

56.548,67

l/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

m3/h

17.671,46

28,95

45,24

70,69

119,46

180,96

282,74

441,79

636,17

1.130,97

1.767,15

2.544,69

3.463,61

4.523,89

5.725,55

7.068,58

8.552,99

10.178,76

11.945,91

13.854,42

15.904,31

18.095,57

22.902,21

28.274,33

40.715,04

47.783,62

55.417,69

63.617,25

72.382,29

81.712,82

91.608,84

113.097,34

0,05 0,5 5 10

table 23

13/14

Flowrate Table (Blue values are preferable)

MUT

220

0 EL

MUT

250

0 EL

14/14The data shown in this catalogue are subject to modification without prior notice.

EUROMAG INTERNATIONAL srl35035 Mestrino (Padova) – Via Torino, 3 – ItalyTel. +39 049 9005064 – Fax +39 049 9007764www.euromag.com